Loading...
HomeMy WebLinkAboutProduct Approval (2) ,Florida Building Code Online 9/5/17, 6:15 AM b NT? 'wn �^+, w.�v s�. ..",� >?�^ "`�* n a �ei. rflsi " `w< €aa .t r 6� x9 ,y��1.aws ee v�rdv s�,� '' i .,cv � "•;� � .�c'{'�,'� 'ic:X' v'��s"� ,w�i Si•ka� �"a" .�.5.���.«i .P"� L, ;� x• $ t BCIS Home j Log In User Registration j Hot Topics ! Submit Surcharge Stats&Facts j Publications FBC Staff BCIS Site Map i Links Search f Fb lda 11 j P Product Approval 5 'USER:Public User Product Approval Menu>Product or Application Search>Application List>Application History_>Application Detail FL# DRn Application Type CCode Version Application Status Approved Comments Archived Product Manufacturer Plastpro Inc:,! Nanya Plastics Corp. Address/Phone/Email CENTURY BLVD. LOS ANGELES,CA 90045 (440) 969-9773 Ext 16 rickw@rwbidgconsultants.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles, CA 90045 (440) 969-9773 Ext 18 scottjohnson@plastproinc.com Quality Assurance Representative Ron O'Connell Address/Phone/Email 5200 W Century Blvd. ' Los Angeles, CA 90045 (440) 969-9773 Ext 16 ronoconnell@plastpro.com Category -xterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 91 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J. King, P.E. r Validation Checklist- Hardcopy Received Certificate of Independence FL15180 RI COI CERTIFICATE of INDEPENDENCE.pdf i https://f,loridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsidcHd6iePBHCLWJ4zwVnPCNLpdxOYYZutBVMYkYFBkA%3d%3d Page 1 of 6 ,Florida Building Code Online 9/5/17, 6:15 AM Referenced Standard and Year(of Standard) Standard Year ASTM D1929 1996 ASTM D1929 2006 ASTM D2843 1999 ASTM D635 1998 ASTM D638 2003 ASTM E1300 2004 ASTM E84 2005 ASTM G26 1995 TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL15180 R1 Equiv Equivalency Of Standards.pdf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/24/2015 Date Validated 04/26/2015 Date Pending FBC Approval 04/28/2015 Date Approved ' 06/23/2015 Date Revised 08/17/2017 i I Summary of Products Go to Page Page 1/2 FL# Model, Number or Name Description 15180.1 a. Smooth/Wood �Serles 6'8 "Impact" Glazed Fiberglass Single Door-Outswing (X- Grain/Rustic/MahogConfiguration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: es FL15180 R1 II_Inst 15180.1.�df Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes `BesiVn Rressure: Nf , "'� ' Evaluation Reports Other: See INST 15180.1 for Design Pressure Ratings, any FL15180_R1 AE Eval 15180.1.12df additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15180.2 b.Smooth/Wood 6'8 "Impact" Glazed Fiberglass Single Door with "Impact" Grain/Rustic/Mahogany Series N Sidelite-Outswing (OX or XO-Configuration) Fiberglass Door i Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15180 E 11 Inst 15180.2.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.2 for Design Pressure Ratings, any FL15180 R1 AE Eval 15180.2.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15180.3 c.Smooth/Wood 6'8 "Impact" Glazed Fiberglass Single Door with"Impact" Grain/Rustic/Mahogany Series N Sidelites-Outswing (OXO-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes https://floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgsidcHd6ieP8HCLWJ4zwVnPCNLpdxOYYZutBVMYkYFBkA%3d%3d Page 2 of 6 - -- - - - ----- - ---- plastpro 'o' 37.W'MAX.OVERALL z 5200 W. CENTURY BLVD. FRAME WIDTH =c�: �* * �_— m LOS ANGELES, CA 90045 z U N Smooth / Flood Grain / White Wood Grain � � •.• .-• Z. N;z Rustic /Mahogany � e a z oZ. Series N Fiberglass Door a y m C! OIL a a OUTSWING z �d ®® E o �y rrilvll-Acr 5 j o 3a lid O O �o y nz w O p-1 U GENERAL NOTES z CD o z OTn?; GU 1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building Code (FBC)structural requirements including the"High Velocity Hurricane Zone"(HVHZ). E y w�, 0 Q-M 2 Z�Cx 2. Product anchors shalt be as listed and spaced as shown on details.Anchor embedment to base material 0, shall be beyond wall dressing or stucco 9 o I EEO �.��'�!>"y'e'ri°"'.°I.",a BRA,,p'aat..."�^�'sB•StF.S...�' -vaimw.'�nwu3rpu ..srM•:'�' 3. When used in the HVHT this product complies with Section 1626 of the Florida Building Code and does not a a require on impact resistant covering. w, �:_,-:' ... - >} 4, When used in areas outside of the"HVHZ"requiring wind borne debris protection this product complies with Section 1609.12 of the FBC and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined In ASTM El996 and Section 1609.1.22 of the FBC. a 5. For N stud framing construction,anchoring of these units shall be the same as that shown for 2x buck 4 z masonry construction. _ W In 6. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. 0 7. Outswing configurations meet water infiltration requirements for"HVHT'. TABLE OF CONTENIS N¢ F SHEET@ DESCR►TON 1 Typical elevation,design pressures,&general notes a z z 2 Door panel details and glaring detail z ° 3 Horizontal cross sections OJfFJiA1l QY�RALL DE5CGIJ PRESStlkEr(FSFf' DATE:32/21 12 i 4 Vertical cross sectionsR�4ME b tCr � scar E: N.T.S. ° 5 Buck and frame anchoring-2X buck masonry construction J ........: .._ ..._ .. _...... ..... __... DWG.BY: JK m 6 1 Frame anchoring-I buck masonry construction Dr: LFS 3 37.50"X 80.50" 20.50' X 62.63" Gl. +$Q.0 -50.0 DHK. 7 BSI of materials&components DanwiHc No.: FL-15180.1 N O SHEET 1 OF 7 N 0.8 G7 0.81" 1.22" 4Q' 1.19" EXTERIOR snLE INTERIOR STILE TOP RAIL TT�1••T o°n m z U N •, (COMP.) (COMP.) (COMP.) \ v_ z x Z o STILE REINFORCEMENT POCK BLOCK ) STILE REINFORCEMENT = \ X N g 9 d L a 20'LONG WOOD v (WOOD) (WOOD) a Y om d D. LL 1 HORIZONTAL CROSS SECTION FOAM CORE o o rt'-.:AABAVYARE.tNARL.'` i`2':?:: .:•:;:;i 2 �a (POLYURETHANE- E cz 1.9PCFMIN.) >,_•. 'MYINOF,6GTORER:i::.ai::>;::>'.::MOA ................. ................... .. .. ;;a:::::"R STRUCTURAL SIUCINE(DOW 995) 5/8"GLASS BITE LOCK: SIGNATURESEWES EA DDSOLT: SIGNATURE SERIES(780) NON STRUCTURAL SEALANT EXT. o YALE CK: N COL O 1"OVERALL GLASS THK. z o DEADROLT: YH COl1ECT10N(80 SERIES) 1/8"ANNEALED GLASS G �LQ N w 35.75'DOOR 0.090"SAFLEX®PVB WIDTH 24.27'MAX. INTERLAYER 3 w N a FRAME WIDTH 2 1/8"ANNEALED GLASS INTERIOR EXTERIOR j a Co D o 20.5TY'MAX. o 2 SPACE AIR D.L.O.WIDTH o 1/8"TEMPERED GLASS o a a #7-19 X 1.3/4"PPH ALUMINUM SPACER �Co/ SELF DRILLING SMS $A INT. NON STRUCTURAL SEALANT U SEE HARDWARE !E GLALNG DETAIL CHART 0 = FIBERGLASS SKIN a (SEE DETAIL) w = ZO 0 0 P cn 4 = 1 LL o 1.86" INTERIOR in 0 2 0 FR O WOVEN . :, r FIBERGLASS cs a '.0 7 Z 0.063" ih N F ui w a CD v ] ZT N ^O O-� Z z O FIBERGLASS SKIN EXTERIOR BOTTOM RAIL c 4.25'� � ��02/2 1 12 ? ODL UTE FRAME 0.069"THK. (COMP.) (nP•) 3A SCALE: N.T.S. ODL LITE FRAME (a0m') DOOR SKIN DETAIL m DWG.ar: JK p 2 VERTICAL CROSS SECTION CNK.sr: LFS 3 2 DRIWMD NO, � DOOR PANEL N 40 FL-15180.1 0 N SHEET 2 OF 7 1-1l4"MIN. \\J * 4 /{ EMB.(TYP.) IN� Q• A Z.W•(� L N Q � Q � O:a—Z� ° 20 21 C A :N z \` >°mtzn U C4 •;d U G Z V L Z m C W a og 9 p o a 1leX e `E "w mda � INTERIOR 40 4 3 p 2 3 o Wchi ° Z O N ON p EXTERIOR 10 H P- 5 m y J 11 5 W N O _ 3 4 ��HORIZONTAL CROSS SECTION o 1-1/a°MIN, o 0 o 1-1/a°MIN. o x EMB.(TYP.) .. $ Shown w/1X sub-buck EMB.(TYP.) Dom. a E xr p a, m D C S`4 C B C-SINK ` . C-SINK (TYP.) (TYP.) r • 20 21 �y ;�� 2D 21 z U) 7 8 �• S 7 � INTERIOR . INTERIOR 40 o f: W : t 3 O l 10 DAB:02121 12 `• D EXTERIOR EXTERIOR K D SCALE: N.T.S. ` ° ° OWG.BY: JK a CHK.BY: I.FS a E 3 HORIZONTAL CROSS SECTION 2 NOR! ONTAL CROSS SECTION E DRAWING NO.: SHEEP_2L OF ] I I 0 a ° N 9 O m V OD z ;u .P Yea ��✓ 1-IM MIN. )-1/4"MIN. EMB.(TYP.) EMB.11yr.) mm A a d y0rn m O Ely v 7 T m rn � z $ p m •' '. .° Al = �m 22 $ x� cA zz n Nff'O N rn n °c N m O m 7a N Oa . o C) Qnn n 1-I M MIN. EMB.(TYP,) ``t,utu, lr,���� � SCHIy� No.43409 t. vvx i E $ PRODUCT: Document. Pnp—d By., a Lyndon F. Schmidt % Z N FIPLASTPERCLASS DOOR P.E. No. 43409 //,//''0 Al- 11 � E r c -f PART OR ASSEMBLY: t� BUILDING CONSULTANTS, INC. Iv p (n 1 4 22 15 UPDATE i0 5TH ED. (2014) F8C JK VERTICAL CROSS SECTIONS VV P.O. BoK 230, Valrico, FL 33595 N NO DATE BY Phone No.: 813.659.9197 REVISIONS FSPE CA No. 9813 20 1 2 R.W.BUILDING CONSULTANTS INC. 4" a 6" a a c•J_d a Z D TYP.HEAD TYP.HEAD ,y 9 i o Z &JAMBS L 8,JAMBS ` '�� E m m o MASONRY7 MASONRY7 . s LL as OPENING OPENING E gz .. `N 'u C Li 1J� 8 a i FRAME Nz 0 ' � o 2X BUCK z oo a o 2X BUCK P-5 co -wu rn d co 2 �d rr N iy Li eQ Li (- a o 0 �{ TYP.Q SILL e a a m°' Co Z BUCKANCHORING STRIKE JAMB FRAMEANCHORING HINGEJAMB F 0 Masonry 2X buck construction N CONCRETE ANCHOR NOTES: h4. n 1. Concrete anchor locations at the comers may be adjusted to maintain the min. " edge distance to mortarjoints. 12 Q 2. Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to ,., a. maintain the min.edge distance to mortar joints,additional concrete anchors may be required to ensure the"MAX.ON CENTER"dimension are not exceeded. 3. Concrete anchor table: 28 M 9 Lu M14 C.ARA:NC ;.;I41:IN:CtE;4RANCR:: ............. :::::::::::.....:...::::.:..:.._;._.:.::;:..:....... .:.,_TC7.iYlA.SONRY;: `' ':rc.-ADJA:-El1F;y.: 1 D TYP.L:;;z... $179 EMBED/NI NL _z i :.. .. .. ...... . ........ ...... ... .........EDGE ITW 11 -ATE--02121 12 i TAPCON® 1/4" 1-1/4" 2" 4" ❑ M , 27 scar£: N.T.S. DWG.BY. JK i ELCO 1/4" 1-1/4" 1" 4" ULTRACON cHK.BY. LFS WOOD SCREW INSTALLATION NOTES: DRAWING No.: � 1.Maintain a minimum 51W edge distance,I"end distance,&1"o.c.spacing of LATCH G DEADBOLT DETAIL HIF:GE DETAIL FL-15180.I ` wood screws to prevent the splitting of wood. SHE Er 5 OF 7 ` FS TYP.HEAD 02 &JAMBS rrri* ►►►� o ro m i U N •• cFi 10 y yC v cZo� < MASONRY n p i° z m c U OPENING 11 M a a V s C E [Z FRAME g ra HINGE DETAIL Y �Z cc m0 1XBUCK cio xj �ci M =o m w C; H TYP.Q SILL `"o G o w 28 a v m EE STRIKE JAMB FRAME ANCHORING HINGE JAMB Masonry I buck construction N CONCRETE ANCHOR NOTES: k LATCH d DEADBOLi DETAIL. w o 1. Concrete anchor locations at the comers maybe adjusted to maintain the min. rn edge distance to mortar joints. t In 2. Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to o maintain the min.edge distance to mortar joints,additional concrete anchors maybe required to ensure the'MAX.ON CENTER"dimension are not exceeded. a 3. Concrete anchor table: j MIN'CL�i4t ANC--.:''•i4110 G:t;�11Ri4(VC�. 'ANCHQR. ANdN.ok ;;`;;:`M/l+Fdt'i<`i.:?;::. ::.....:.....:........:.,,;...•..•..,,.. ..,,.....,.,..,.:...,..:•:>:: i1?P .. ....: ....$t�l: .. . MbMJ NT iL31VIASONRY TO v4QJACBIJI;;. w :.._ .........•. •... ......:::::•::::::: :: ::::.:.:>.:.:.:.•:::..:::::»:•:EQCxE ... :::(: TAITW 1/4" 1.1/4" 2" 4" a o z c ELCO ULTRACON® 1/4" 1.1/4" 1" 4" DATE 02/21/12 SCALE: N.T.S. ' ITW ® 3/16" 1-1/4" 3" 1-1/2" DWG.aY: JK i TAPCON CHK.BY: LFS WOOD SCREW INSTAVARON NOTES: owvnHc NO.: 1.Maintain a minimum 5/8"edge distance,I"end distance,8.I"o.c.spacing of FL—16180.1 ` wood screws to prevent the splitting of wood. SHEET 6 OF 7 ' • DBILLA :of MATERIALS ?a; IfE61 Y DESCRIPTION MADiR1AL loe•J�� � A I X BUCK SG>=0.55 WOOD _U V B 2X BUCK SG>=0.55 WOOD N�. z da C 1/4"MAX.SHIM SPACE - �'`• gg� z r/1 / /•••.•�• \ J 0 t0 N D 1/4"X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL �- 4.56" -{ /i/ y ri 0 MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI o ° Z E CONCRETE �► 1 u��` U N •; 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 h o x i� G 3/16"X 3-1/4"PFH ITW CONCRETE SCREW STEEL H 1/4"X 3-1/4"PFH ELCO OR ITW CONCRETE SCREW STEEL I N E N g 9 o L a J 1/4"X 3-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL Z, 236"—t—2.2" �' a E 4 m d a 2 K #9 X 2-1/2'PFH WOOD SCREW STEEL � Z L #8 X 2-1/2'PFH WOOD SCREW STEEL N ' w M #8 X 2'PFH WOOD SCREW STEEL 20 amb!L SIDE $ o 7 FORCE 5 WEATHERSTRIPPING BY ENDURA FOAM 8 COMPRESSION WEATHERSTRIP QLON 650 BY SCHLEGEL FOAM 9 4"X 4"BUTT HINGE STEEL n 10 #9 X l"PFH WOOD SCREW STEEL ci a s 11 #9 X 3/4"PFH WOOD SCREW STEEL z 20 FINGER JOINTED PINE FRAME,HEAD&HINGE JAMBS WOOD 4.56" oc N 5 a 21 POLY FIBER JAMB COMP./VINYL I S w N o0 27 LATCH STRIKE PLATE STEEL (L m a 41 28 DEADBOLT STRIKE PLATE STEEL `` m o 29 OUTSWING THRESHOLD BY DLP ALUM./WOOD 40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS 2.44„ 213" �m 21 HEAD 3 SIDE Poly fiberjamb v 0 N (n z o 4.56' N 2.03"—� E i N F- 29 OUISWING THRESHOLD BY DLP a o i z i z c DATE:0212. 12 `• SCALE N.T.S. ` DWG.BY: JK o CHK.sY: LFS DRAWING NO.: r FL-15180.1 ` c SHEEP ] OF ] r — — 6