HomeMy WebLinkAboutReview Comments lank Planning B Development Services REVIEW COMMENTS Building S Code Regulation Division 2300 Virginia Avenue Fort Pierce,FL. 34982 Phone:(772)462-2172 Fax:(772)462-6443 Page 1 PROPERTY INFORMATION Address: 6703 Oneco Way Owner(s): Robert N Dollar City/State/Zip: Fort Pierce, FI 34951 Pal cel#: 1301-611-0158-000/5 Jurisdiction: SAINT LUCIE COUNTY Z6�ing: RS-4 Lot#: 11 Block: 107 APPLICATION INFORMATION Pelrmit Number: 1710-0065 Stories: Automatic Sprinkler System? No Permit Type: BUILDING RESIDENTIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Christopher Dales Fax Number: 772-774-4853 Business Name: Coast To Coast Builders Of FI Inc Business Addr: 4835 50Th Dr Email: Coasttocoastbuildersofflorid a@Gmail.Com City/State/Zip: Vero Beach, FI 32967 RI VIEWS AND COMMENTS RelviewTvoe Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Deanna Givens 10/4/2017 10/4/2017 Comment: NOTICE OF COMMENCEMENT FRONT COUNTER REVIEW COMPLETE Deanna Givens 10/4/2017 10/4/2017 10/4/2017 Comment: PLANS EXAMINER REVIEW INCOMPLETE William Durden 11/25/2017 Comment: •PLEASE FURNISH ENERGY CALULATIONS AND MANUAL J IN ACCORDANCE WITH SECTIONS 402 AND 403 11/25/2017 OF THE 2014 FLORIDA ENERGY CODE.NOTE ONLY;ENERGIES MUST HAVE ORIGINAL SIGNATURE OF PREPARER Comment: • PLEASE SUBMIT THE ROOF UNDERLAYMENT PRODUCT APPROVALS IN DUPLICATE.MEETING THE 11/25/2017 REQUIREMENTS OF CHAPTER 9 SECTION R905.10.5 SUBSECTION R105.10.5.2 OF THE 2014 FLORIDA BUIDING CODE. Comment: •PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND 11/25/2017 APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE 11/25/2017 Comment: •PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2014 FLORIDA BUILDING, CODE 11/25/2017 Comment: •PLEASE SHOW STRAPING DETAIL FOR HEADERS PER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE 11/25/2017 Comment: •PLEASE FURNISH A INTERIOR WALL DETAIL SHOWING STUD SPACING,STUD SIZE,AND WALL FINISH IN ACCORDANCE WITH 602.2 OF THE 2014 FLORIDA BUILDING CODE 11/25/2017 Comment: •PLEASE FURNISH A DUCT PLAN SHOWING A BALANCED SYSTEM,DUCT SIZE,GRILL SIZE,AND ROOM BY ROOM CFMS PER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE _ Comment: •PLEASE SUBMIT THE ENERGY PERFOMANCE SHEETS OR SUBMIT A THE NFRC FENSTRATION 11/25/2017 MANUFACTURE CERTIFICATE FOR THE U-FACTOR AND THE SHGC FOR EACH GLAZED OPENING SHOWING COMPLIANCE WITH CHAPTER 4 SECTION 402.1.1 OF THE 2014 ENERGY CODE FIFTH EDITION. i AdElk 'Planning&Development Services REVIEW COMMENTS 'Building&Code Regulation Division 2300 Virginia Avenue Fort Pierce,FL. 34982 P one:(772)462-2172 Fax:(772)462-6443 Page 2 ZONING REVIEW INCOMPLETE Comment: William Durden 260CT18 Plans Examiner St. Lucie County Plan ning/Development 2300 Virginia Avenue Ft. Pierce, FL 34982 RE: 6703 Oneco Way, Fort Pierce, FL 34951 PERMIT: 1710-0065 Mr. Durden. Firstly, thanks. The resolution of the issues you addressed for me the other day that have either bored or chased away the architect and builder I found to legitimize my VET home loan/FannieMae Renovation Loan is greatly appreciated. I simply want to do everything I can to bring my new home into compliance. I am submitting this cover letter with two copies of the duct plan/register plan you requested I provide. Shortly, I will round up the Energy Calcs/Manual J document you requested. An attempt will be made to re-integrate Arch. John Foster into assisting with the effort to bring my home into compliance. Thanks. Robert Dollar 305-200-7990 robertdollar@yahoo.com RECEIVE® OCT 2 9 2018 Permitting Department St. Lucie Counter, FL