Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFING12/29/21, 11:05 AM Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABq3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d 1/5 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL27499-R4 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Dynamic Metals Address/Phone/Email 3201 SE Dominica Terace Stuart, FL 34997 (772) 872-8030 juan@dynamicmetal.net Authorized Signature Lara Jesus juan@dynamicmetal.net Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Scott Wolters Florida License PE-62354 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/06/2026 Validated By Lucas A. Turner, P.E., MBA Validation Checklist - Hardcopy Received Certificate of Independence FL27499_R4_COI_Dyn COI.pdf Referenced Standard and Year (of Standard)Standard Year TAS 100 1995 TAS 110 2000 TAS 125 2003 Equivalence of Product Standards Certified By Sections from the Code 12/29/21, 11:05 AM Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABq3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d 2/5 Product Approval Method Method 1 Option D Date Submitted 04/18/2021 Date Validated 04/30/2021 Date Pending FBC Approval 05/03/2021 Date Approved 06/08/2021 Summary of Products Go to Page Page 1 / 2 FL #Model, Number or Name Description 27499.1 DM Class 1000 1" Nailstrip 26 Ga. galvalume coated steel roof panel, 16" wide, with 1" snap fit seams. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation Instructions FL27499_R4_II_4991 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4991 Eval.pdf Created by Independent Third Party: Yes 27499.2 DM Class 1000 1" Nailstrip,.032" Aluminum roof panel, 16" wide, with 1" snap fit seams. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation Instructions FL27499_R4_II_4992 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4992 Eval.pdf Created by Independent Third Party: Yes 27499.3 DM Class 1050 1 1/2" Nailstrip .032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit seams. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation Instructions FL27499_R4_II_4993 Dwg.pdf Verified By: Scott Wolters, P.E. FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4993 Eval.pdf Created by Independent Third Party: Yes 27499.4 DM Class 1050 1 1/2" Nailstrip 24 Ga. Galvalume coated steel roof panel, 19" wide, with 1 1/2" snap fit seams Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation Instructions FL27499_R4_II_4994 Dwg.pdf Verified By: Scott Wolters, P.E. FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4994 Eval.pdf Created by Independent Third Party: Yes 27499.5 DM Class 1150 1" Mechanical Seam .032" Aluminum roof panel, 21" wide, with 1" standing seams. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval Report for Limits of Use. Installation Instructions FL27499_R4_II_4995 Dwg.pdf Verified By: Scott Wolters FLPE# 62394 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4995 Eval.pdf Created by Independent Third Party: Yes 27499.6 DM Class 1150 1" Mechanical Seam .032" Aluminum roof panel, 21" wide, with 1" standing seams. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Installation Drawings and Eval Report for Limits of Use. Installation Instructions FL27499_R4_II_4996 Dwg.pdf Verified By: Scott Wolters FLPE# 62394 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4996 Eval.pdf Created by Independent Third Party: Yes 27499.7 DM Class 1150 1" Mechanical Seam 26 Ga. Galvalume coated steel roof panel, 21" wide, with 1" standing seams. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Installation Instructions FL27499_R4_II_4997 Dwg.pdf Verified By: Scott Wolters FLPE# 62394 12/29/21, 11:05 AM Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABq3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d 3/5 Impact Resistant: N/A Design Pressure: N/A Other: Please see Installation Drawings and Eval Report for Limits of Use. Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4997 Eval.pdf Created by Independent Third Party: Yes 27499.8 DM Class 1500 1 1/2" Mechanical Seam .032" Aluminum roof panel, 20" wide, with 1 1/2" standing seams. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation Instructions FL27499_R4_II_4998 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4998 Eval.pdf Created by Independent Third Party: Yes 27499.9 DM Class 1500 1 1/2" Mechanical Seam 16 oz. Copper roof panel, 16" wide, with 1 1/2" standing seams. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation Instructions FL27499_R4_II_4999 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4999 Eval.pdf Created by Independent Third Party: Yes 27499.10 DM Class 1500 1 1/2" Mechanical Seam 26 Ga. galvalume coated steel roof panel, 16" wide, with 1 1/2" standing seams. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation Instructions FL27499_R4_II_49910 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49910 Eval.pdf Created by Independent Third Party: Yes 27499.11 DM Class 1500 1 1/2" Mechanical Seam .032" Aluminum roof panel, 16" wide, with 1 1/2" standing seams. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation Instructions FL27499_R4_II_49911 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49911 Eval.pdf Created by Independent Third Party: Yes 27499.12 DM Class 1500 1 1/2" Mechanical Seam 24 Ga. galvalume coated steel roof panel, 16" wide, with 1 1/2" standing seams. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation Instructions FL27499_R4_II_49912 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49912 Eval.pdf Created by Independent Third Party: Yes 27499.13 DM Class 1500 1 1/2" Mechanical Seam, 24 Ga. galvalume coated steel roof panel, 20" wide, with 1 1/2" standing seams. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation Instructions FL27499_R4_II_49913 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49913 Eval.pdf Created by Independent Third Party: Yes 27499.14 DM Class 1750 1 3/4" Snaplock 24 Ga. Galvalume coated steel roof panel, 18" wide, with 1 3/4" Snaplock seams, attached to metal deck. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation Instructions FL27499_R4_II_49914 Dwg.pdf Verified By: Scott Wolters, P.E. FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49914 Eval.pdf Created by Independent Third Party: Yes 27499.15 DM Class 1750 1 3/4" Snaplock .032" Aluminum roof panel, 18" wide, with 1 3/4" Snaplock seams, attached to metal deck. 12/29/21, 11:05 AM Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABq3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d 4/5 Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation Instructions FL27499_R4_II_49915 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49915 Eval.pdf Created by Independent Third Party: Yes 27499.16 DM Class 1750 1 3/4" Snaplock .032" aluminum roof panel, 18" wide, with 1 3/4" Snaplock seams. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation Instructions FL27499_R4_II_49916 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49916 Eval.pdf Created by Independent Third Party: Yes 27499.17 DM Class 1750 1 3/4" Snaplock 24 Ga. galvalume coated steel roof panel, 18" wide, with 1 3/4" Snaplock seams. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation Instructions FL27499_R4_II_49917 dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49917 Eval.pdf Created by Independent Third Party: Yes 27499.18 DM Class 2000 2" Mechanical Seam .032 Aluminum roof panel, 18" wide, with 2" standing seams. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation Instructions FL27499_R4_II_49918 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49918 Eval.pdf Created by Independent Third Party: Yes 27499.19 DM Class 2000 2" Mechanical Seam 24 Ga. galvalume coated steel roof panel, 18" wide, with 2" standing seams. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation Instructions FL27499_R4_II_49919 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49919 Eval.pdf Created by Independent Third Party: Yes 27499.20 DM Class 500 5V Crimp 26 Ga. galvalume coated steel roof panel, 24" wide, with 5V crimp. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation Instructions FL27499_R4_II_49920 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49920 Eval.pdf Created by Independent Third Party: Yes Go to Page Page 1 / 2 Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 12/29/21, 11:05 AM Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABq3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d 5/5 SPECIALIZING IN IMPACT RESISTANT CURTAINWALLS, STOREFRONTS, & WINDOWS Option #1 Option #2 Installation Installation Max. Design Pressure: -116 psf -176 psf Fastener Spacing: 3" From Ends, 6" Max. O.C. 3" From Ends, 6" Max. O.C. Min Panel Fasteners: #10x1" Panclip Fasteners #10x1" Panclip Fasteners Panel Sealant: Continuous bead of Geocell 2300 Continuous bead of Geocel 2300 or 2320 at Nailstrip side of seam (at roof slopes <3”/12” only) or 2320 at Nailstrip side of seam Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note #2 below) Note: Outside of the HVHZ in areas with windspeeds < 170 mph, 1” round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Underlayment: Minimum ASTM D 226 Type II, installed and anchored per FBC Section 1507.1.1.1 (min). (or) Any underlayment with a valid FLPA or Miami-Dade NOA Note: Outside of the HVHZ in areas with windspeeds < 170 mph, 1” round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Minimum Substrate: ½’ (15/32” min) 4-ply CDX Plywood or ¾” solid wood planks (S.G. = .42 min) nailed to 2x rafters spaced 24” max. on center with 8d ring-shank nails spaced 6” on center. Note: The ¾” wood planking must be installed as a solid deck and must be nailed or fastened in a manner equal to the deck above, or as specified by a Florida licensed Architect/Engineer Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation.