HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFING12/29/21, 11:05 AM Florida Building Code Online
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABq3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d 1/5
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL27499-R4
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Dynamic Metals
Address/Phone/Email 3201 SE Dominica Terace
Stuart, FL 34997
(772) 872-8030
juan@dynamicmetal.net
Authorized Signature Lara Jesus
juan@dynamicmetal.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
Scott Wolters
Florida License PE-62354
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/06/2026
Validated By Lucas A. Turner, P.E., MBA
Validation Checklist - Hardcopy Received
Certificate of Independence FL27499_R4_COI_Dyn COI.pdf
Referenced Standard and Year (of Standard)Standard Year
TAS 100 1995
TAS 110 2000
TAS 125 2003
Equivalence of Product Standards
Certified By
Sections from the Code
12/29/21, 11:05 AM Florida Building Code Online
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABq3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d 2/5
Product Approval Method Method 1 Option D
Date Submitted 04/18/2021
Date Validated 04/30/2021
Date Pending FBC Approval 05/03/2021
Date Approved 06/08/2021
Summary of Products
Go to Page Page 1 / 2
FL #Model, Number or Name Description
27499.1 DM Class 1000 1" Nailstrip 26 Ga. galvalume coated steel roof panel, 16" wide, with 1"
snap fit seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499_R4_II_4991 Dwg.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_4991 Eval.pdf
Created by Independent Third Party: Yes
27499.2 DM Class 1000 1" Nailstrip,.032" Aluminum roof panel, 16" wide, with 1" snap fit seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499_R4_II_4992 Dwg.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_4992 Eval.pdf
Created by Independent Third Party: Yes
27499.3 DM Class 1050 1 1/2" Nailstrip .032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit
seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499_R4_II_4993 Dwg.pdf
Verified By: Scott Wolters, P.E. FLPE# 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_4993 Eval.pdf
Created by Independent Third Party: Yes
27499.4 DM Class 1050 1 1/2" Nailstrip 24 Ga. Galvalume coated steel roof panel, 19" wide, with 1
1/2" snap fit seams
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499_R4_II_4994 Dwg.pdf
Verified By: Scott Wolters, P.E. FLPE# 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_4994 Eval.pdf
Created by Independent Third Party: Yes
27499.5 DM Class 1150 1" Mechanical Seam .032" Aluminum roof panel, 21" wide, with 1" standing seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval Report for Limits of Use.
Installation Instructions
FL27499_R4_II_4995 Dwg.pdf
Verified By: Scott Wolters FLPE# 62394
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_4995 Eval.pdf
Created by Independent Third Party: Yes
27499.6 DM Class 1150 1" Mechanical Seam .032" Aluminum roof panel, 21" wide, with 1" standing seams.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Installation Drawings and Eval Report for
Limits of Use.
Installation Instructions
FL27499_R4_II_4996 Dwg.pdf
Verified By: Scott Wolters FLPE# 62394
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_4996 Eval.pdf
Created by Independent Third Party: Yes
27499.7 DM Class 1150 1" Mechanical Seam 26 Ga. Galvalume coated steel roof panel, 21" wide, with 1"
standing seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Installation Instructions
FL27499_R4_II_4997 Dwg.pdf
Verified By: Scott Wolters FLPE# 62394
12/29/21, 11:05 AM Florida Building Code Online
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABq3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d 3/5
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Installation Drawings and Eval Report for
Limits of Use.
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_4997 Eval.pdf
Created by Independent Third Party: Yes
27499.8 DM Class 1500 1 1/2" Mechanical
Seam
.032" Aluminum roof panel, 20" wide, with 1 1/2" standing
seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499_R4_II_4998 Dwg.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_4998 Eval.pdf
Created by Independent Third Party: Yes
27499.9 DM Class 1500 1 1/2" Mechanical
Seam
16 oz. Copper roof panel, 16" wide, with 1 1/2" standing
seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499_R4_II_4999 Dwg.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_4999 Eval.pdf
Created by Independent Third Party: Yes
27499.10 DM Class 1500 1 1/2" Mechanical
Seam
26 Ga. galvalume coated steel roof panel, 16" wide, with 1 1/2"
standing seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499_R4_II_49910 Dwg.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_49910 Eval.pdf
Created by Independent Third Party: Yes
27499.11 DM Class 1500 1 1/2" Mechanical
Seam
.032" Aluminum roof panel, 16" wide, with 1 1/2" standing
seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499_R4_II_49911 Dwg.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_49911 Eval.pdf
Created by Independent Third Party: Yes
27499.12 DM Class 1500 1 1/2" Mechanical
Seam
24 Ga. galvalume coated steel roof panel, 16" wide, with 1 1/2"
standing seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499_R4_II_49912 Dwg.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_49912 Eval.pdf
Created by Independent Third Party: Yes
27499.13 DM Class 1500 1 1/2" Mechanical
Seam,
24 Ga. galvalume coated steel roof panel, 20" wide, with 1 1/2"
standing seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499_R4_II_49913 Dwg.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_49913 Eval.pdf
Created by Independent Third Party: Yes
27499.14 DM Class 1750 1 3/4" Snaplock 24 Ga. Galvalume coated steel roof panel, 18" wide, with 1
3/4" Snaplock seams, attached to metal deck.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499_R4_II_49914 Dwg.pdf
Verified By: Scott Wolters, P.E. FLPE# 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_49914 Eval.pdf
Created by Independent Third Party: Yes
27499.15 DM Class 1750 1 3/4" Snaplock .032" Aluminum roof panel, 18" wide, with 1 3/4" Snaplock
seams, attached to metal deck.
12/29/21, 11:05 AM Florida Building Code Online
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABq3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d 4/5
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499_R4_II_49915 Dwg.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_49915 Eval.pdf
Created by Independent Third Party: Yes
27499.16 DM Class 1750 1 3/4" Snaplock .032" aluminum roof panel, 18" wide, with 1 3/4" Snaplock
seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499_R4_II_49916 Dwg.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_49916 Eval.pdf
Created by Independent Third Party: Yes
27499.17 DM Class 1750 1 3/4" Snaplock 24 Ga. galvalume coated steel roof panel, 18" wide, with 1 3/4"
Snaplock seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499_R4_II_49917 dwg.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_49917 Eval.pdf
Created by Independent Third Party: Yes
27499.18 DM Class 2000 2" Mechanical Seam .032 Aluminum roof panel, 18" wide, with 2" standing seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499_R4_II_49918 Dwg.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_49918 Eval.pdf
Created by Independent Third Party: Yes
27499.19 DM Class 2000 2" Mechanical Seam 24 Ga. galvalume coated steel roof panel, 18" wide, with 2"
standing seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499_R4_II_49919 Dwg.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_49919 Eval.pdf
Created by Independent Third Party: Yes
27499.20 DM Class 500 5V Crimp 26 Ga. galvalume coated steel roof panel, 24" wide, with 5V
crimp.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499_R4_II_49920 Dwg.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499_R4_AE_49920 Eval.pdf
Created by Independent Third Party: Yes
Go to Page Page 1 / 2
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
12/29/21, 11:05 AM Florida Building Code Online
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABq3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d 5/5
SPECIALIZING IN IMPACT RESISTANT CURTAINWALLS, STOREFRONTS, & WINDOWS
Option #1 Option #2
Installation Installation
Max. Design Pressure: -116 psf -176 psf
Fastener Spacing: 3" From Ends, 6" Max. O.C. 3" From Ends, 6" Max. O.C.
Min Panel Fasteners: #10x1" Panclip Fasteners #10x1" Panclip Fasteners
Panel Sealant: Continuous bead of Geocell 2300 Continuous bead of Geocel 2300
or 2320 at Nailstrip side of seam
(at roof slopes <3”/12” only)
or 2320 at Nailstrip side of seam
Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the fire barrier within the assembly. (See note #2 below)
Note: Outside of the HVHZ in areas with windspeeds < 170 mph, 1” round
plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be
used to prevent galvanic reactions.
Underlayment: Minimum ASTM D 226 Type II, installed and anchored per FBC Section
1507.1.1.1 (min).
(or)
Any underlayment with a valid FLPA or Miami-Dade NOA
Note: Outside of the HVHZ in areas with windspeeds < 170 mph, 1” round
plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be
used to prevent galvanic reactions.
Minimum Substrate: ½’ (15/32” min) 4-ply CDX Plywood or ¾” solid wood planks (S.G. = .42
min) nailed to 2x rafters spaced 24” max. on center with 8d ring-shank
nails spaced 6” on center.
Note: The ¾” wood planking must be installed as a solid deck and must be
nailed or fastened in a manner equal to the deck above, or as specified by
a Florida licensed Architect/Engineer
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or
1515.2.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation.