Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutREQUIREMENTS FOR WIND UPLIFT RESISTANCESNEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 1 of 75
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
TABLE DECK APPLICATION TYPE DESCRIPTION PAGE
1A Wood New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 5-6
1B Wood New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6-7
1C Wood New, Reroof (Tear-Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 8
1D Wood New, Reroof (Tear-Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 9-10
1E Wood New, Reroof (Tear-Off) or Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 11-13
1F Wood New, Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 13-16
1G Wood New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 16-18
1H Wood New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 18
2A Steel or Structural concrete New, Reroof (Tear-Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 19-22
2B Steel or Structural concrete New, Reroof (Tear-Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 22-26
2C Steel or Structural concrete New, Reroof (Tear-Off) or Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 27-29
3A Structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 30-39
3B Structural concrete New or Reroof (Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier, Bonded Insulation, Bonded Roof Cover 40
3C Structural concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 40
4A LWIC / steel New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 41-42
4B LWIC / structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 43-49
4C LWIC / structural concrete New, Reroof (Tear-Off) A-1 Bonded Vapor Barrier, Bonded Insulation, Bonded Roof Cover 50-51
4D LWIC / steel New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 52-54
4E LWIC / steel or struct. conc. New or Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 55-59
4F LWIC / steel Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 60
4G LWIC / steel Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 60
5A Cementitious wood fiber New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 61-62
5B Cementitious wood fiber New or Reroof (Tear-Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 63
5C Cementitious wood fiber Reroof (Tear-Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 64
5D Cementitious wood fiber New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 64
6A Existing gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 65-67
6B Existing gypsum Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 68
6C Existing gypsum Reroof (Tear-Off) C-1 Mech. Attached Insulation, Bonded Roof Cover 69
6D Existing gypsum Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 69
7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 70-75
7B Various Recover F Non-Insulated, Bonded Roof Cover 75
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 2 of 75
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:
➢ Wood Deck: FlintFast #14 Fastener with FlintFast 3” Insulation Plates, Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3, OMG #14 Roofgrip with Flat Bottom Plate (Accutrac), OMG HD
with OMG 3 in. Galvalume Steel Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plates. Minimum ¾-inch plywood penetration or minimum 1-inch wood plank embedment.
➢ Steel Deck: FlintFast #12 or #14 Fastener with FlintFast 3” Insulation Plates, Dekfast DF-#12-PH3 or DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3, OMG #12 or #14 Roofgrip with Recessed
or Flat Bottom Plate (Accutrac), OMG #12 Standard or HD with OMG 3 in. Galvalume Steel Plate or Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plates or. Minimum
¾-inch steel penetration and engage the top flute of the steel deck.
➢ Structural Concrete: FlintFast #14 Fastener with FlintFast 3” Insulation Plates, Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3, OMG #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac),
OMG HD or CD-10 with OMG 3 in. Galvalume Steel Plate or Trufast #14 HD or Trufast Fluted Concrete Nail with Trufast 3” Metal Insulation Plates. Minimum 1-inch embedment. Fasteners
installed with a pilot hole in accordance with the fastener manufacturer’s published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
4. Minimum 200 psi, minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for rigid insulation board for System Types B, C or D, whereby fasteners are installed through the lightweight
insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall
be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues, such as deck
venting or moisture levels within the LWIC and the potential effect on overlying components.
5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020).
6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application, the ribbons/beads shall expand as noted in the manufacturer’s published instructions.
➢ hot asphalt: Full coverage at 25-30 lbs/square
➢ “FlintFast QS Insulation Adhesive” (FlintFast QS): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. Note: HB Fuller “Millennium One Step Foamable Adhesive” may be used
wherever FlintFast QS is listed.
➢ “FlintFast LV Insulation Adhesive” (FlintFast LV): Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c. Note: HB Fuller “Millennium PG-1 Pump Grade Adhesive” may be used
wherever FlintFast LV is listed.
➢ Dupont “INSTA STIK Quik Set Commercial Roofing Adhesive” (Insta Stik QS): Continuous 0.75 to 1 inch wide ribbons, 12-inch o.c.
➢ ICP Adhesives and Sealants “Polyset Board-Max”: Continuous 3-inch ribbons, 12-inch o.c.
➢ ICP Adhesives and Sealants “Polyset CR-20”: Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c.
➢ OMG OlyBond 500 Adhesive Fastener (OB500): Continuous 0.75-inch wide ribbons, 12-inch o.c. (PaceCart, SpotShot or Canister)
➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, boards shall be staggered from layer-to-layer.
➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7. Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables, rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the
thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table:
➢ FlintFast QS: MDP -157.5 psf (Min. 1.0-inch)
➢ FlintFast LV: MDP -157.5 psf (Min. 1.0-inch)
➢ Insta Stik QS: MDP -120.0 psf (Min. 1.0-inch)
➢ Polyset CR-20: MDP -117.5 psf (Min. 1.0-inch)
➢ OB500: MDP -45.0 psf (Min. 0.5-inch Multi-Max FA3)
➢ OB500: MDP -187.5 psf (Min. 0.5-inch ISO 95+ GL)
➢ OB500: MDP -315.0 psf (Min. 0.5-inch ENRGY 3)
➢ OB500: MDP -487.5 psf (Min. 0.5-inch ACFoam II)
8. For adhered roof insulation and board-size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020).
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 3 of 75
9. For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance
with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM
Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss
Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements.
10. For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational
analysis is permitted for these systems.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum
requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed.
If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane
over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented
through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type D, the insulation is optional. Alternatively, an FBC Approved
insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator component shall be documented as
meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications.
14. Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC
Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat
thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For “pre-existent” LWIC references, listings were established through testing over lightweight concrete cast
using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami-Dade BCCO (FBC CER1592). Use of these listings in
new construction or re-roof (tear-off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction.
15. Unless otherwise noted, refer to the following references for bonded applications.
MEMBRANE / ADHESIVE COMBINATIONS
REFERENCE LAYER MATERIAL APPLICATION
SBS-CA1
Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Karnak No. 81 Cold Process Modified Bitumen Adhesive Brush
Grade at 1 gal/square
Note: Base ply cures overnight prior to application of the ply or cap ply.
Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Cap Ply: Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic
Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar
BP-CA2 Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20
Henry #903 Adhesive at 1.5 gal/square. SBS-CA2
Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Cap Ply: Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic
Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar
BP-CA3 Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20
HB Fuller “Millennium Hurricane Force Membrane Adhesive”,
beads spaced 6-inch o.c. SBS-CA3
Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Cap Ply: Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic
Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 4 of 75
MEMBRANE / ADHESIVE COMBINATIONS
REFERENCE LAYER MATERIAL APPLICATION
SBS-CA4
Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
FlintBond Brush or Tropical Roofing Products #216 Modified
Bitumen Adhesive at 1 to 1.5 gal/square.
Note: Base ply cures overnight prior to application of the ply or cap ply.
Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Cap Ply: Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic
Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar
BP-AA Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 hot asphalt at 20-40 lbs/square Ply: One or more Flintglas Ply 4, Flintglas Premium Ply 6
SBS-AA
Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
hot asphalt at 20-40 lbs/square Ply: One or more Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base
Cap Ply: Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic
Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar
SBS-TA
Base Ply: Flintlastic Ultra Poly SMS Base Sheet, Flintlastic Base 20 T
torch-applied Ply: One or more Flintlastic Ultra Poly SMS Base Sheet, Flintlastic Base 20 T
Cap Ply: Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar
APP-TA
Base Ply: One or more Flintlastic APP Base T, Flintlastic STA, Flintlastic STA Plus
torch-applied Cap Ply: Flintlastic STA, Flintlastic STA Plus, Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR, Flintlastic
GTA-FR CoolStar
SBS-SA-H Base Ply: Black Diamond Base Sheet, Flintlastic Ultra Glass SA self-adhering (activated by overlying membrane)
SBS-SA
Base Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply
self-adhering Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply
Cap Ply: Flintlastic SA Cap, Flintlastic SA Cap FR CoolStar, Flintlastic SA Cap FR, Flintlastic SA Cap FR CoolStar
16. Vapor barrier options for use over structural concrete deck followed by adhesive-applied insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in
Table 3A applies:
VAPOR BARRIER OPTIONS, STRUCTURAL CONCRETE DECK, ADHERED INSULATION PER TABLE 3A, (The lesser of the MDP listings below vs. those in Table 3A applies)
OPTION
# PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP
(PSF) TYPE ATTACH
VB-1. FlintPrime QD, Karnak #108
or ASTM D41 Flintlastic SA PlyBase Self-adhering OB500, 12-inch o.c. -82.5
VB-2. None
All Weather/Empire Base Sheet, 3-inch wide side laps and 6-inch wide end laps
are sealed with HB Fuller “HB Fuller “Millennium Hurricane Force Lap and
Flashing Adhesive”
HB Fuller “Millennium Hurricane Force
Membrane Adhesive HS”, max. 6-inch
o.c.
FlintFast QS or FlintFast LV,
12-inch o.c. -82.5
VB-3. None
Flintlastic Ultra Poly SMS Base Sheet, 3-inch wide side laps and 6-inch wide end
laps are hot-air-welded, torch-welded or sealed with HB Fuller “HB Fuller
“Millennium Hurricane Force Lap and Flashing Adhesive”
HB Fuller “Millennium Hurricane Force
Membrane Adhesive HS”, max. 6-inch
o.c.
FlintFast QS or FlintFast LV,
12-inch o.c. -82.5
VB-4. FlintPrime QD, Karnak #108
or ASTM D41 primer Black Diamond Base Sheet, Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering FlintFast QS or FlintFast LV,
12-inch o.c. -97.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 5 of 75
VAPOR BARRIER OPTIONS, STRUCTURAL CONCRETE DECK, ADHERED INSULATION PER TABLE 3A, (The lesser of the MDP listings below vs. those in Table 3A applies)
OPTION
# PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP
(PSF) TYPE ATTACH
VB-5. FlintPrime QD, Karnak #108
or ASTM D41 primer Black Diamond Base Sheet, Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering FlintFast QS or FlintFast LV,
6-inch o.c. -315.0
VB-6. ASTM D41 or Karnak #108
Asphalt Primer Flintlastic GTA Torch-applied FlintFast QS or FlintFast LV,
12-inch o.c. -420.0
VB-7. FlintPrime QD, Karnak #108
or ASTM D41 primer Flintlastic Base 20 T or Flintlastic FR Cap 30 T Torch-applied FlintFast QS or FlintFast LV,
12-inch o.c. -495.0
17. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1)
Base Insulation Top Insulation
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
SELF-ADHERING SYSTEMS:
W-1
Min. 15/32-inch APA
rated CDX plywood,
24-inch span
Min. 1.5-inch FlintBoard
ISO, ACFoam II, FlintBoard
H ISO, H-Shield
FlintFast QS or
FlintFast LV
(Optional) Additional layer(s) of base
insulation and/or min. 0.25-inch
DensDeck Prime or SECUROCK Gypsum-
Fiber Roof Board.
FlintFast QS or
FlintFast LV
FlintPrime QD,
Karnak #108
or ASTM D41
primer
SBS-SA (Optional) SBS-
SA SBS-SA -60.0
W-2
Min. 15/32-inch APA
rated CDX plywood,
24-inch span,
blocked 48-inch o.c.
Min. 1.5-inch FlintBoard
ISO, ACFoam II, FlintBoard
H ISO, H-Shield
FlintFast QS or
FlintFast LV, 6-
inch o.c.
(Optional) Additional layer(s) of base
insulation and/or min. 0.25-inch
DensDeck Prime or SECUROCK Gypsum-
Fiber Roof Board.
FlintFast QS or
FlintFast LV, 6-
inch o.c.
FlintPrime QD,
Karnak #108
or ASTM D41
primer
SBS-SA (Optional) SBS-
SA SBS-SA -97.5
HYBRID SYSTEMS:
W-3
Min. 15/32-inch APA
rated CDX plywood,
24-inch span
Min. 1.5-inch FlintBoard
ISO, ACFoam II, FlintBoard
H ISO, H-Shield
FlintFast QS or
FlintFast LV
(Optional) Additional layer(s) of base
insulation and/or min. 0.25-inch
DensDeck Prime or SECUROCK Gypsum-
Fiber Roof Board.
FlintFast QS or
FlintFast LV None SBS-SA-H
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
W-4
Min. 15/32-inch APA
rated CDX plywood,
24-inch span,
blocked 48-inch o.c.
Min. 1.5-inch FlintBoard
ISO, ACFoam II, FlintBoard
H ISO, H-Shield
FlintFast QS or
FlintFast LV, 6-
inch o.c.
(Optional) Additional layer(s) of base
insulation and/or min. 0.25-inch
DensDeck Prime or SECUROCK Gypsum-
Fiber Roof Board.
FlintFast QS or
FlintFast LV, 6-
inch o.c.
None SBS-SA-H
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-97.5
CONVENTIONAL SYSTEMS:
W-5
Min. 15/32-inch APA
rated CDX plywood,
24-inch span
Min. 1.5-inch FlintBoard
ISO, ACFoam II, FlintBoard
H ISO, H-Shield
FlintFast QS or
FlintFast LV
Optional additional layers of base
insulation, followed by min. 0.25-inch
DensDeck Prime or SECUROCK Gypsum-
Fiber Roof Board
FlintFast QS or
FlintFast LV None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 6 of 75
TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1)
Base Insulation Top Insulation
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
W-6
Min. 15/32-inch APA
rated CDX plywood,
24-inch span,
blocked 48-inch o.c.
Min. 1.5-inch FlintBoard
ISO, ACFoam II, FlintBoard
H ISO, H-Shield
FlintFast QS or
FlintFast LV, 6-
inch o.c.
Optional additional layers of base
insulation, followed by min. 0.25-inch
DensDeck Prime or SECUROCK Gypsum-
Fiber Roof Board.
FlintFast QS or
FlintFast LV, 6-
inch o.c.
None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-97.5
TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation
Primer
Roof Cover (Note 15)
MDP
(psf) Type Fasteners Attach Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
SELF-ADHERING SYSTEMS:
W-7
Min. 19/32-
inch
plywood,
24-inch
span
Glasbase Base Sheet,
All Weather/Empire
Base Sheet,
Flintlastic Base 20,
Poly SMS, Ultra Poly
SMS
32 ga., 1-5/8-
inch dia. tin
caps with 11
ga. annular
ring shank
nails
9-inch o.c. in 4-inch
lap and 12-inch o.c.
in two (2), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3, H-Shield,
FlintBoard ISOH or
Multi-Max FA3
hot asphalt
Min. 0.25-
inch
DensDeck
hot asphalt
FlintPrime
QD,
Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -
45.0*
W-8
Min. 19/32-
inch
plywood,
24-inch
span
Glasbase Base Sheet,
All Weather/Empire
Base Sheet, Poly SMS
or Ultra Poly SMS
32 ga., 1-5/8-
inch dia. tin
caps with 11
ga. annular
ring shank
nails
8-inch o.c. in 3-inch
lap and 8-inch o.c. in
three (3), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3, H-Shield,
FlintBoard ISOH or
Multi-Max FA3
hot asphalt full
coverage or
FlintFast QS,
Insta Stik QS,
OB500, Polyset
Board-Max or
Polyset CR-20,
4-inch o.c.
Min. 0.25-
inch
DensDeck
hot asphalt full
coverage or
FlintFast QS,
Insta Stik QS,
OB500, Polyset
Board-Max or
Polyset CR-20,
6-inch o.c.
FlintPrime
QD,
Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -52.5
W-9
Min. 19/32-
inch
plywood,
24-inch
span
Glasbase Base Sheet,
All Weather/Empire
Base Sheet, Poly SMS
or Ultra Poly SMS
32 ga., 1-5/8-
inch dia. tin
caps with 11
ga. annular
ring shank
nails
8-inch o.c. in 3-inch
lap and 8-inch o.c. in
three (3), equally
spaced, staggered
center rows
(Optional) Min. 1.5-
inch ACFoam II,
FlintBoard ISO,
ENRGY 3, H-Shield,
FlintBoard ISOH or
Multi-Max FA3
hot asphalt full
coverage or
FlintFast QS,
Insta Stik QS,
OB500, Polyset
Board-Max or
Polyset CR-20,
4-inch o.c.
Min. 0.25-
inch
SECUROCK
Gypsum-
Fiber Roof
Board
hot asphalt full
coverage or
FlintFast QS,
Insta Stik QS,
OB500, Polyset
Board-Max or
Polyset CR-20,
6-inch o.c.
FlintPrime
QD,
Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -60.0
HYBRID SYSTEMS:
W-10
Min. 19/32-
inch
plywood,
24-inch
span
Glasbase Base Sheet,
All Weather/Empire
Base Sheet,
Flintlastic Base 20,
Poly SMS, Ultra Poly
SMS
32 ga., 1-5/8-
inch dia. tin
caps with 11
ga. annular
ring shank
nails
9-inch o.c. in 4-inch
lap and 12-inch o.c.
in two (2), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3, H-Shield,
FlintBoard ISOH or
Multi-Max FA3
hot asphalt None N/A None SBS-SA-H
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-
45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 7 of 75
TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
Sys.
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation
Primer
Roof Cover (Note 15)
MDP
(psf) Type Fasteners Attach Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
W-11
Min. 19/32-
inch
plywood at
max. 24-
inch
Glasbase Base Sheet,
Flintglas Premium Ply
6
32 ga., 1-5/8-
inch dia. tin
caps with 11
ga. annular
ring shank
nails
8-inch o.c. in 3-inch
lap and 8-inch o.c. in
three (3), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3, H-Shield,
FlintBoard ISOH or
Multi-Max FA3
hot asphalt None N/A None SBS-SA-H
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
CONVENTIONAL SYSTEMS:
W-12
Min. 19/32-
inch
plywood,
24-inch
span
Glasbase Base Sheet,
All Weather/Empire
Base Sheet,
Flintlastic Base 20,
Poly SMS, Ultra Poly
SMS
32 ga., 1-5/8-
inch dia. tin
caps with 11
ga. annular
ring shank
nails
9-inch o.c. in 4-inch
lap and 12-inch o.c.
in two (2), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3, H-Shield,
FlintBoard ISOH or
Multi-Max FA3
hot asphalt
Min. 0.25-
inch
DensDeck
hot asphalt
ASTM D41
or Karnak
#108
Asphalt
Primer
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-
45.0*
W-13
Min. 19/32-
inch
plywood,
24-inch
span
Glasbase Base Sheet,
All Weather/Empire
Base Sheet, Poly SMS
or Ultra Poly SMS
32 ga., 1-5/8-
inch dia. tin
caps with 11
ga. annular
ring shank
nails
8-inch o.c. in 3-inch
lap and 8-inch o.c. in
three (3), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3, H-Shield,
FlintBoard ISOH or
Multi-Max FA3
hot asphalt full
coverage or
FlintFast QS,
Insta Stik QS,
OB500, Polyset
Board-Max or
Polyset CR-20,
4-inch o.c.
Min. 0.25-
inch
DensDeck
hot asphalt full
coverage or
FlintFast QS,
Insta Stik QS,
OB500, Polyset
Board-Max or
Polyset CR-20,
6-inch o.c.
ASTM D41
or Karnak
#108
Asphalt
Primer
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-52.5
W-14
Min. 19/32-
inch
plywood,
24-inch
span
Glasbase Base Sheet,
All Weather/Empire
Base Sheet, Poly SMS
or Ultra Poly SMS
32 ga., 1-5/8-
inch dia. tin
caps with 11
ga. annular
ring shank
nails
8-inch o.c. in 3-inch
lap and 8-inch o.c. in
three (3), equally
spaced, staggered
center rows
(Optional) Min. 1.5-
inch ACFoam II,
FlintBoard ISO,
ENRGY 3, H-Shield,
FlintBoard ISOH or
Multi-Max FA3
hot asphalt full
coverage or
FlintFast QS,
Insta Stik QS,
OB500, Polyset
Board-Max or
Polyset CR-20,
4-inch o.c.
Min. 0.25-
inch
SECUROCK
Gypsum-
Fiber Roof
Board
hot asphalt full
coverage or
FlintFast QS,
Insta Stik QS,
OB500, Polyset
Board-Max or
Polyset CR-20,
6-inch o.c.
None
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 8 of 75
TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
MDP (psf) Type Fasteners Attach Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
HYBRID SYSTEMS:
W-15 Min. 15/32-inch
plywood, 24-inch span
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
ISOH.
FlintFast #12 or
#14 with
FlintFast 3”
Insulation Plates
1 per
1.3 ft2
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield or
FlintBoard ISOH.
hot asphalt,
FlintFast QS,
FlintFast LV,
Insta Stik QS,
OB500
SBS-SA-H (Optional) APP-TA APP-TA -67.5
CONVENTIONAL SYSTEMS:
W-16 Min. 23/32-inch
plywood, 24-inch span
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY 3, H-Shield,
FlintBoard ISOH
Note 2 1 per
2.0 ft2
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation, min. 0.75-inch
FescoBoard (homogeneous)
hot asphalt BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
W-17 Min. 23/32-inch
plywood, 24-inch span
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY 3, H-Shield,
FlintBoard ISOH
Note 2 1 per
2.0 ft2
Min. 0.25-inch DensDeck,
DensDeck Prime or
SECUROCK Gypsum-Fiber
Roof Board
hot asphalt
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
W-18 Min. 15/32-inch
plywood, 24-inch span
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
ISOH.
FlintFast #12 or
#14 with
FlintFast 3”
Insulation Plates
1 per
1.3 ft2
Optional additional layer(s) of
base insulation followed by
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof board
hot asphalt,
FlintFast QS,
FlintFast LV,
Insta Stik QS,
OB500
APP-TA (Optional) APP-TA APP-TA -90.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 9 of 75
TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP
(psf) Type Fasteners Attach Base Ply Ply Cap Ply
SELF-ADHERING SYSTEMS:
W-19
Min. 15/32-inch
plywood, 24-inch
span
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast #12 or #14 with
FlintFast 3 in. Insulation Plate or
Trufast #12 DP or #14 HD with
Trufast 3” Metal Insulation Plate
1 per
3.2 ft2 None SBS-SA (Optional) SBS-
SA SBS-SA -30.0*
W-20
Min. 19/32-inch
plywood, 24-inch
span
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch DensDeck Note 2 1 per
1.3 ft2
FlintPrime
QD, Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional) SBS-
SA SBS-SA -45.0
W-21
Min. 19/32-inch
plywood, 24-inch
span
(Optional) One or more
layers, any combination,
loose laid
Min. 3/8-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast #12 or #14 with
FlintFast 3 in. Insulation Plate or
Trufast #12 DP or #14 HD with
Trufast 3” Metal Insulation Plate
1 per
2.7 ft2 None SBS-SA (Optional) SBS-
SA SBS-SA -45.0*
W-22
Min. 19/32-inch
plywood, 24-inch
span
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH,
Multi-Max FA3
FlintFast #12 or #14 with
FlintFast 3 in. Insulation Plate or
Trufast #12 DP or #14 HD with
Trufast 3” Metal Insulation Plate
1 per
2.0 ft2
FlintPrime
QD, Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional) SBS-
SA SBS-SA -45.0*
W-23
Min. 15/32-inch
plywood, 24-inch
span
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch FlintBoard ISO
FlintFast #14 with FlintFast 3 in.
Insulation Plate or Trufast #14
HD with Trufast 3” Metal
Insulation Plate
1 per
1.6 ft2
FlintPrime
QD, Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional) SBS-
SA SBS-SA -52.5
W-24
Min. 19/32-inch
plywood, 24-inch
span
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH,
Multi-Max FA3
Note 2 1 per
1.45 ft2
FlintPrime
QD, Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional) SBS-
SA SBS-SA -60.0
HYBRID SYSTEMS:
W-25
Min. 15/32-inch
plywood, 24-inch
span
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch DensDeck,
DensDeck Prime
FlintFast #12 or #14 with
FlintFast 3 in. Insulation Plate or
Trufast #12 DP or #14 HD with
Trufast 3” Metal Insulation Plate
1 per
2.0 ft2 None SBS-SA-
H
(Optional) BP-
AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -30.0*
W-26
Min. 15/32-inch
plywood, 24-inch
span
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch FlintBoard ISO
FlintFast #14 with FlintFast 3 in.
Insulation Plate or Trufast #14
HD with Trufast 3” Metal
Insulation Plate
1 per
1.6 ft2 None SBS-SA-
H
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -52.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 10 of 75
TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP
(psf) Type Fasteners Attach Base Ply Ply Cap Ply
W-27
Min. 15/32-inch
plywood, 24-inch
span
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3 or
Multi-Max FA3
Note 2 1 per
1.3 ft2 None SBS-SA-
H
(Optional) BP-
AA or SBS-AA SBS-AA -52.5
W-28
Min. 19/32-inch
plywood, 24-inch
span
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
Note 2 1 per
1.45 ft2 None SBS-SA-
H
(Optional) BP-
AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -60.0
W-29
Min. 15/32-inch
plywood, 24-inch
span
(Optional) Min. 1.5-inch, One
or more layers, any
combination, loose laid
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast #12 or #14 with
FlintFast 3 in. Insulation Plate or
Trufast #12 DP or #14 HD with
Trufast 3” Metal Insulation Plate
1 per
1.3 ft2 None SBS-SA-
H
(Optional) SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -75.0
W-30
Min. 19/32-inch
plywood, 24-inch
span
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3 or
Multi-Max FA3
Note 2 1 per
1.3 ft2 None SBS-SA-
H
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -82.5
CONVENTIONAL SYSTEMS:
W-31
Min. 23/32-inch
plywood, 24-inch
span
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation, min. 0.75-inch
FescoBoard (homogeneous)
Note 2 1 per
2.0 ft2 None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -45.0*
W-32
Min. 15/32-inch
plywood, 24-inch
span
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch DensDeck,
DensDeck Prime or
SECUROCK Gypsum-Fiber
Roof Board
FlintFast #12 or #14 with
FlintFast 3 in. Insulation Plate or
Trufast #12 DP or #14 HD with
Trufast 3” Metal Insulation Plate
1 per
2.0 ft2 None
BP-AA,
SBS-AA,
SBS-TA
or APP-
TA
(Optional) BP-
AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -45.0*
W-33
Min. 15/32-inch
plywood, 24-inch
span
(Optional for Recover) Min.
1.5-inch, One or more layers,
any combination, loose laid
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast #12 or #14 with
FlintFast 3 in. Insulation Plate or
Trufast #12 DP or #14 HD with
Trufast 3” Metal Insulation Plate
1 per
1.45 ft2 None APP-TA (Optional) APP-
TA APP-TA -60.0
W-34
Min. 19/32-inch
plywood, 24-inch
span
(Optional for Concrete or
Recover) Min. 2-inch ACFoam
II, FlintBoard, H-Shield or
ENRGY 3, loose laid.
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast #12 or #14 with
FlintFast 3 in. Insulation Plate or
Trufast #12 DP or #14 HD with
Trufast 3” Metal Insulation Plate
1 per
1.8 ft2 None
BP-AA,
SBS-AA,
SBS-TA
or APP-
TA
(Optional) BP-
AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -60.0
W-35
Min. 15/32-inch
plywood, 24-inch
span
(Optional for Recover) Min.
1.5-inch, One or more layers,
any combination, loose laid
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast #12 or #14 with
FlintFast 3 in. Insulation Plate or
Trufast #12 DP or #14 HD with
Trufast 3” Metal Insulation Plate
1 per
1.3 ft2 None APP-TA (Optional) APP-
TA APP-TA -67.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 11 of 75
TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Insulation Layer(s) (Note 13) Base Sheet Primer Roof Cover (Note 15) MDP
(psf) Type Attach Type Fasteners Attach Base Ply Cap Ply
SELF-ADHERING SYSTEMS:
W-36
Min. 19/32-inch
plywood, 24-inch
span
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach Flintlastic SA NailBase Note 2
8-inch o.c. at min. 3-inch lap
and 8-inch o.c. in two (2),
equally spaced, staggered
center rows
Prime stress
plates with
Karnak #108
(Optional)
SBS-SA SBS-SA -82.5*
W-37
Min. 15/32-inch
plywood, 24-inch
span
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach Flintlastic SA NailBase
FlintFast #12 or #14 with
FlintFast 3 in. Insulation Plate,
OMG #14 HD with OMG 3 in.
Round Metal Plate or Trufast
#12 DP or #14 HD with Trufast
3” Metal Insulation Plate
6-inch o.c. at min. 2-inch lap
and 6-inch o.c. in three (3),
equally spaced, staggered
center rows
Prime stress
plates with
Karnak #108
(Optional)
SBS-SA SBS-SA -97.5*
W-38
Min. 15/32-inch
plywood, 24-inch
span
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach Flintlastic SA NailBase
FlintFast #12 or #14 with
FlintFast 3 in. Insulation Plate,
OMG #14 HD with OMG 3 in.
Round Metal Plate or Trufast
#12 DP or #14 HD with Trufast
3” Metal Insulation Plate
6-inch o.c. at min. 2-inch lap
and 6-inch o.c. in four (4),
equally spaced, staggered
center rows
Prime stress
plates with
Karnak #108
(Optional)
SBS-SA SBS-SA -127.5*
HYBRID SYSTEMS:
W-39
Min. 15/32-inch
plywood, 24-inch
span
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase Base Sheet,
Flintlastic Base 20,
Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra
Poly SMS Base Sheet
FlintFast #12 or #14 with
FlintFast 3 in. Insulation Plate,
OMG #14 HD with OMG 3 in.
Round Metal Plate or Trufast
#12 DP or #14 HD with Trufast
3” Metal Insulation Plate
6-inch o.c. at 4-inch lap and 6-
inch o.c. in three (3), equally
spaced, staggered center rows
Prime stress
plates with
Karnak #108
SBS-SA-H
SBS-AA,
SBS-TA or
APP-TA
-97.5
W-40
Min. 19/32-inch
plywood, 24-inch
span
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase Base Sheet,
Flintlastic Base 20,
Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra
Poly SMS Base Sheet
Note 2
7-inch o.c. at 3-inch lap and 7-
inch o.c. in three (3), equally
spaced, staggered center rows
None SBS-SA-H
SBS-AA,
SBS-TA or
APP-TA
-105.0
W-41
Min. 15/32-inch
plywood, 24-inch
span
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase Base Sheet,
Flintlastic Base 20,
Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra
Poly SMS Base Sheet
FlintFast #12 or #14 with
FlintFast 3 in. Insulation Plate,
OMG #14 HD with OMG 3 in.
Round Metal Plate or Trufast
#12 DP or #14 HD with Trufast
3” Metal Insulation Plate
6-inch o.c. at 4-inch lap and 6-
inch o.c. in four (4), equally
spaced, staggered center rows
Prime stress
plates with
Karnak #108
SBS-SA-H
SBS-AA,
SBS-TA or
APP-TA
-127.5
CONVENTIONAL SYSTEMS:
W-42
Min. 23/32-inch
plywood, 24-inch
span
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase Base Sheet, All
Weather/Empire Base
Sheet, Flintlastic Base 20
Note 2
12-inch o.c. at 4-inch lap and
36-inch o.c. in two (2), equally
spaced, staggered center rows
None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-30.0*
W-43
Min. 23/32-inch
plywood, 24-inch
span
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase Base Sheet, All
Weather/Empire Base
Sheet, Flintlastic Base 20
Note 2
12-inch o.c. at 4-inch lap and
24-inch o.c. in two (2), equally
spaced, staggered center rows
None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 12 of 75
TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Insulation Layer(s) (Note 13) Base Sheet Primer Roof Cover (Note 15) MDP
(psf) Type Attach Type Fasteners Attach Base Ply Cap Ply
W-44
Min. 23/32-inch
plywood, 24-inch
span
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra
Poly SMS Base Sheet
Note 2
12-inch o.c. at 4-inch lap and
36-inch o.c. in two (2), equally
spaced, staggered center rows
None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
W-45
Min. 15/32-inch
plywood, 24-inch
span
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet, Flintlastic Poly
SMS Base Sheet,
Flintlastic Ultra Poly SMS
Base Sheet
FlintFast #12 or #14 with
FlintFast 3 in. Insulation Plate,
OMG #14 HD with OMG 3 in.
Round Metal Plate or Trufast
#12 DP or #14 HD with Trufast
3” Metal Insulation Plate
6-inch o.c. at 4-inch lap and 6-
inch o.c. in three (3), equally
spaced, staggered center rows.
None
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-97.5
W-46
Min. 15/32-inch
plywood, 24-inch
span
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach Flintlastic APP Base T OMG #14 HD with OMG 3 in.
Round Metal Plates
6-inch o.c. at 4-inch lap and 6-
inch o.c. in three (3), equally
spaced, staggered center rows.
None APP-TA APP-TA -97.5
W-47
Min. 15/32-inch
plywood, 24-inch
span
One or more
layers, any
thickness or
combination
Prelim.
Attach
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet, Flintlastic Poly
SMS Base Sheet,
Flintlastic Ultra Poly SMS
Base Sheet
FlintFast #14 with FlintFast 3 in.
Insulation Plate or Trufast #14
HD with Trufast 3” Metal
Insulation Plate
8-inch o.c. at 4-inch lap and 8-
inch o.c. at three (3) equally
spaced, staggered center rows
None
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP_TA
-97.5
W-48
Min. 19/32-inch
plywood, 24-inch
span
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase Base Sheet,
Flintlastic Base 20,
Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra
Poly SMS Base Sheet
Note 2
7-inch o.c. at 3-inch lap and 7-
inch o.c. in three (3), equally
spaced, staggered center rows
None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-105.0
W-49
Min. 19/32-inch
plywood, 24-inch
span
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach Flintlastic APP Base T
Dekfast DF-#14-PH3 with PLT-H-
2-7/8 or OMG #14 HD with
OMG 3 in. Round Metal Plate
7-inch o.c. at 3-inch lap and 7-
inch o.c. in three (3), equally
spaced, staggered center rows
None APP-TA APP-TA -105.0
W-50
Min. 15/32-inch
plywood, 24-inch
span
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach
Glasbase Base Sheet,
Flintlastic Base 20,
Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra
Poly SMS Base Sheet
FlintFast #12 or #14 with
FlintFast 3 in. Insulation Plate,
OMG #14 HD with OMG 3 in.
Round Metal Plate or Trufast
#12 DP or #14 HD with Trufast
3” Metal Insulation Plate
6-inch o.c. at 4-inch lap and 6-
inch o.c. in four (4), equally
spaced, staggered center rows.
None
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-127.5
W-51
Min. 15/32-inch
plywood, 24-inch
span
Min. 1.5-inch, One
or more layers,
any combination
Prelim.
Attach Flintlastic APP Base T OMG #14 HD with OMG 3 in.
Round Metal Plates
6-inch o.c. at 4-inch lap and 6-
inch o.c. in four (4), equally
spaced, staggered center rows.
None APP-TA APP-TA -127.5
COLD-APPLIED SYSTEMS:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 13 of 75
TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Insulation Layer(s) (Note 13) Base Sheet Primer Roof Cover (Note 15) MDP
(psf) Type Attach Type Fasteners Attach Base Ply Cap Ply
W-52
Min. 15/32-inch
plywood, 24-inch
span
Min. 1-inch, One
or more layers,
any combination
Loose-
laid
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet, Flintlastic Poly
SMS Base Sheet,
Flintlastic Ultra Poly SMS
Base Sheet
FlintFast #12 or #14 with
FlintFast 3 in. Insulation Plate or
Trufast #12 DP or #14 HD with
Trufast 3” Metal Insulation Plate
8-inch o.c. at 4-inch lap and 8-
inch o.c. in three (3), equally
spaced, staggered center rows
None (Optional)
SBS-CA1 SBS-CA1 -52.5
TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Primer Roof Cover (Note 15) MDP
(psf) Base Fasteners Attach Base Ply Cap Ply
SELF-ADHERING SYSTEMS:
W-53 Min. 15/32-inch
plywood, 24-inch span Flintlastic SA NailBase Simplex MAXX Cap
9-inch o.c. at min. 3-inch lap and 12-inch
o.c. in two (2), equally spaced, staggered
center rows
ASTM D41
primer at
plates
(Optional)
SBS-SA SBS-SA -45.0*
W-54 Min. 15/32-inch
plywood, 24-inch span Flintlastic SA NailBase Min. 1-inch long, 12 ga. Simplex Metal
Cap Nails
6-inch o.c. at min. 2-inch lap and 6-inch
o.c. in four (4), equally spaced,
staggered center rows
None (Optional)
SBS-SA SBS-SA -52.5
W-55
Min. 19/32-inch
plywood, 24-inch
span
Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11
ga. annular ring shank nails
8-inch o.c. at min. 2-inch lap and 8-inch
o.c. in three (3), equally spaced,
staggered center rows
None (Optional)
SBS-SA SBS-SA -52.5
W-56
APA rated, min. 7/16
CAT, 0.418 in.,
Exposure 1, OSB, 24-
inch span
Flintlastic SA NailBase Simplex MAXX Cap
8-inch o.c. at min. 3-inch lap and 8-inch
o.c. in three (3), equally spaced,
staggered center rows
ASTM D41
primer at
plates
(Optional)
Flintlastic SA
Mid Ply, self-
adhering
SBS-SA -52.5
W-57 Min. 19/32-inch
plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11
ga. annular ring shank nails
8-inch o.c. at min. 2-inch lap and 8-inch
o.c. in three (3), equally spaced,
staggered center rows
None (Optional)
SBS-SA SBS-SA -60.0
W-58 Min. 15/32-inch
plywood, 24-inch span Flintlastic SA NailBase Simplex MAXX Cap
8-inch o.c. at min. 3-inch lap and 8-inch
o.c. in three (3), equally spaced,
staggered center rows
ASTM D41
primer at
plates
(Optional)
SBS-SA SBS-SA -67.5
W-59 Min. 19/32-inch
plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11
ga. annular ring shank nails
6-inch o.c. at min. 2-inch lap and 6-inch
o.c. in four (4), equally spaced,
staggered center rows
None (Optional)
SBS-SA SBS-SA -75.0
W-60 Min. 15/32-inch
plywood, 24-inch span Flintlastic SA NailBase
Cap nails: 1-inch diameter, 0.032-inch
thick metal cap with 0.120" shank
diameter, annular ring shank nails
7-inch o.c. at min. 4-inch laps and 7-inch
o.c. in five (5), equally spaced, staggered
center rows
None (Optional)
SBS-SA SBS-SA -75.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 14 of 75
TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Primer Roof Cover (Note 15) MDP
(psf) Base Fasteners Attach Base Ply Cap Ply
W-61 Min. 19/32-inch
plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11
ga. annular ring shank nails
4-inch o.c. at min. 2-inch lap and 4-inch
o.c. in four (4), equally spaced,
staggered center rows
None (Optional)
SBS-SA SBS-SA -105.0
HYBRID SYSTEMS:
W-62 Min. 19/32-inch
plywood, 24-inch span
Glasbase Base Sheet, Flintlastic Base
20, All Weather/Empire Base Sheet,
Flintlastic Poly SMS Base Sheet,
Flintlastic Ultra Poly SMS Base Sheet
32 ga., 1-5/8-inch dia. tin caps with 11
ga. annular ring shank nails
9-inch o.c. at 4-inch lap and 12-inch o.c.
in two (2), equally spaced, staggered
center rows
None SBS-SA-H SBS-AA, SBS-
TA or APP-TA -45.0*
W-63 Min. 15/32-inch
plywood, 24-inch span
Glasbase Base Sheet, Flintlastic Base
20, All Weather/Empire Base Sheet,
Flintlastic Poly SMS Base Sheet,
Flintlastic Ultra Poly SMS Base Sheet
Min. 1-inch long, 12 ga. Simplex Metal
Cap Nails
6-inch o.c. at 3-inch lap and 6-inch o.c. in
four (4), equally spaced, staggered
center rows
None SBS-SA-H SBS-AA, SBS-
TA or APP-TA -52.5
W-64 Min. 19/32-inch
plywood, 24-inch span
Glasbase Base Sheet, Flintlastic Base
20, Flintlastic Poly SMS Base Sheet,
Flintlastic Ultra Poly SMS Base Sheet
32 ga., 1-5/8-inch dia. tin caps with 11
ga. annular ring shank nails
8-inch o.c. at 4-inch lap and 8-inch o.c. in
three (3), equally spaced, staggered
center rows
None SBS-SA-H SBS-AA, SBS-
TA or APP-TA -52.5
W-65 Min. 19/32-inch
plywood, 24-inch span
Glasbase Base Sheet, Flintlastic Base
20, Flintlastic Poly SMS Base Sheet,
Flintlastic Ultra Poly SMS Base Sheet
32 ga., 1-5/8-inch dia. tin caps with 11
ga. annular ring shank nails
8-inch o.c. at 4-inch lap and 8-inch o.c. in
three (3), equally spaced, staggered
center rows
None SBS-SA-H SBS-AA, SBS-
TA or APP-TA -60.0
W-66 Min. 19/32-inch
plywood, 24-inch span
Glasbase Base Sheet, Flintlastic Base
20, Flintlastic Poly SMS Base Sheet,
Flintlastic Ultra Poly SMS Base Sheet
32 ga., 1-5/8-inch dia. tin caps with 11
ga. annular ring shank nails
6-inch o.c. at 4-inch lap and 6-inch o.c. in
four (4), equally spaced, staggered
center rows
None SBS-SA-H SBS-AA, SBS-
TA or APP-TA -82.5
W-67 Min. 19/32-inch
plywood, 24-inch span
Glasbase Base Sheet, Flintlastic Base
20, Flintlastic Poly SMS Base Sheet,
Flintlastic Ultra Poly SMS Base Sheet
32 ga., 1-5/8-inch dia. tin caps with 11
ga. annular ring shank nails
4-inch o.c. at 3-inch lap and 4-inch o.c. in
four (4), equally spaced, staggered
center rows
None SBS-SA-H SBS-AA, SBS-
TA or APP-TA -105.0
CONVENTIONAL SYSTEMS:
W-68 Min. 19/32-inch
plywood, 24-inch span
Glasbase Base Sheet, Flintlastic Base
20, All Weather/Empire Base Sheet,
Flintlastic Poly SMS Base Sheet,
Flintlastic Ultra Poly SMS Base Sheet
32 ga., 1-5/8-inch dia. tin caps with 11
ga. annular ring shank nails
9-inch o.c. at 4-inch lap and 12-inch o.c.
in two (2), equally spaced, staggered
center rows
None
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
W-69 Min. 15/32-inch
plywood, 24-inch span
Glasbase Base Sheet, Flintlastic Base
20, All Weather/Empire Base Sheet,
Flintlastic Poly SMS Base Sheet
Simplex MAXX Cap
9-inch o.c. at 2-inch lap and 18-inch o.c.
in two (2), equally spaced, staggered
center rows
None
(Optional) BP-
AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
W-70 Min. 15/32-inch
plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap
9-inch o.c. at 2-inch lap and 18-inch o.c.
in two (2), equally spaced, staggered
center rows
None (Optional)
APP-TA APP-TA -45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 15 of 75
TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Primer Roof Cover (Note 15) MDP
(psf) Base Fasteners Attach Base Ply Cap Ply
W-71 Min. 15/32-inch
plywood, 24-inch span
Glasbase Base Sheet, Flintlastic Base
20, All Weather/Empire Base Sheet,
Flintlastic Poly SMS Base Sheet,
Flintlastic Ultra Poly SMS Base Sheet
Min. 1-inch long, 12 ga. Simplex Metal
Cap Nails
6-inch o.c. at 3-inch lap and 6-inch o.c. in
four (4), equally spaced, staggered
center rows
None
(Optional) BP-
AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -52.5
W-72 Min. 19/32-inch
plywood, 24-inch span
Glasbase Base Sheet, Flintlastic Base
20, All Weather/Empire Base Sheet,
Flintlastic Poly SMS Base Sheet,
Flintlastic Ultra Poly SMS Base Sheet
32 ga., 1-5/8-inch dia. tin caps with 11
ga. annular ring shank nails
8-inch o.c. at 4-inch lap and 8-inch o.c. in
three (3), equally spaced, staggered
center rows
None
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -52.5
W-73 Min. 15/32-inch
plywood, 24-inch span
Glasbase Base Sheet, Flintlastic Base
20, All Weather/Empire Base Sheet,
Flintlastic Poly SMS Base Sheet
Simplex MAXX Cap
9-inch o.c. at 2-inch lap and 12-inch o.c.
in two (2), equally spaced, staggered
center rows
None
(Optional) BP-
AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -52.5
W-74 Min. 15/32-inch
plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap
9-inch o.c. at 2-inch lap and 12-inch o.c.
in two (2), equally spaced, staggered
center rows
None (Optional)
APP-TA APP-TA -52.5
W-75 Min. 19/32-inch
plywood, 24-inch span
Glasbase Base Sheet, Flintlastic Base
20, All Weather/Empire Base Sheet,
Flintlastic Poly SMS Base Sheet,
Flintlastic Ultra Poly SMS Base Sheet
32 ga., 1-5/8-inch dia. tin caps with 11
ga. annular ring shank nails
8-inch o.c. at 4-inch lap and 8-inch o.c. in
three (3), equally spaced, staggered
center rows
None
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -60.0
W-76 Min. 15/32-inch
plywood, 24-inch span
Glasbase Base Sheet, Flintlastic Base
20, All Weather/Empire Base Sheet,
Flintlastic Poly SMS Base Sheet,
Flintlastic Ultra Poly SMS Base Sheet
Cap nails: 1-inch diameter, 0.032-inch
thick metal cap with 0.120-inch shank
diameter, annular ring shank nails.
6-inch o.c. at 4-inch lap and 6-inch o.c.
at five (5) equally spaced, staggered
center rows
None
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -67.5
W-77 Min. 19/32-inch
plywood, 24-inch span
Glasbase Base Sheet, Flintlastic Base
20, All Weather/Empire Base Sheet,
Flintlastic Poly SMS Base Sheet,
Flintlastic Ultra Poly SMS Base Sheet
32 ga., 1-5/8-inch dia. tin caps with 11
ga. annular ring shank nails
6-inch o.c. at 4-inch lap and 6-inch o.c. in
four (4), equally spaced, staggered
center rows
None
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -82.5
W-78 Min. 15/32-inch
plywood, 24-inch span
Glasbase Base Sheet, Flintlastic Base
20, All Weather/Empire Base Sheet,
Flintlastic Poly SMS Base Sheet
Simplex MAXX Cap
6-inch o.c. at 2-inch lap and 6-inch o.c. in
two (2), equally spaced, staggered
center rows
None
(Optional) BP-
AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -90.0
W-79 Min. 15/32-inch
plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap
6-inch o.c. at 2-inch lap and 6-inch o.c. in
two (2), equally spaced, staggered
center rows
None (Optional)
APP-TA APP-TA -90.0
W-80 Min. 19/32-inch
plywood, 24-inch span
Glasbase Base Sheet, Flintlastic Base
20, All Weather/Empire Base Sheet,
Flintlastic Poly SMS Base Sheet,
Flintlastic Ultra Poly SMS Base Sheet
32 ga., 1-5/8-inch dia. tin caps with 11
ga. annular ring shank nails
4-inch o.c. at 3-inch lap and 4-inch o.c. in
four (4), equally spaced, staggered
center rows
None
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -105.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 16 of 75
TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Primer Roof Cover (Note 15) MDP
(psf) Base Fasteners Attach Base Ply Cap Ply
W-81 Min. 15/32-inch
plywood, 24-inch span
Glasbase Base Sheet, Flintlastic Base
20, All Weather/Empire Base Sheet,
Flintlastic Poly SMS Base Sheet
Simplex MAXX Cap
6-inch o.c. at 2-inch lap and 6-inch o.c. in
three (3), equally spaced, staggered
center rows
None
(Optional) BP-
AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -105.0
W-82 Min. 15/32-inch
plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap
6-inch o.c. at 2-inch lap and 6-inch o.c. in
three (3), equally spaced, staggered
center rows
None (Optional)
APP-TA APP-TA -105.0
TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Primer Roof Cover (Note 15) MDP
(psf) Base Fasteners Attach Base Ply Cap Ply
SELF-ADHERING SYSTEMS:
W-83
APA rated, min.
7/16 CAT, 0.418 in.,
Exposure 1, OSB,
24-inch span
Flintlastic SA NailBase Trufast Versa Fasteners & Plates, two (2)
screws per plate at 180° from each other*
9-inch o.c. at min. 3-inch lap and
12-inch o.c. in two (2), equally
spaced, staggered center rows
ASTM D41
primer at
plates
(Optional)
Flintlastic SA
Mid Ply, self-
adhering
SBS-SA -60.0*
Note: *For re-roof (tear-off) or recover applications, field withdrawal resistance testing (Note 11) shall yield minimum 109 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may
be utilized to produce minimum withdrawal resistance. For recover installations, screws shall be of sufficient length for minimum 1” penetration through OSB sheathing.
W-84
Min. 19/32-inch
plywood, 24-inch
span
Flintlastic SA NailBase Note 2
8-inch o.c. at min. 3-inch lap and
8-inch o.c. in two (2), equally
spaced, staggered center rows
Prime stress
plates with
Karnak #108
(Optional)
SBS-SA SBS-SA -82.5*
W-85
Min. 15/32-inch
plywood, 24-inch
span
Flintlastic SA NailBase
FlintFast #12 or #14 with FlintFast 3 in.
Insulation Plate, OMG #14 HD with OMG 3 in.
Round Metal Plate or Trufast #12 DP or #14
HD with Trufast 3” Metal Insulation Plate
6-inch o.c. at min. 2-inch lap and
6-inch o.c. in three (3), equally
spaced, staggered center rows
Prime stress
plates with
Karnak #108
(Optional)
SBS-SA SBS-SA -97.5*
W-86
Min. 15/32-inch
plywood, 24-inch
span
Flintlastic SA NailBase
FlintFast #12 or #14 with FlintFast 3 in.
Insulation Plate, OMG #14 HD with OMG 3 in.
Round Metal Plate or Trufast #12 DP or #14
HD with Trufast 3” Metal Insulation Plate
6-inch o.c. at min. 2-inch lap and
6-inch o.c. in four (4), equally
spaced, staggered center rows
Prime stress
plates with
Karnak #108
(Optional)
SBS-SA SBS-SA -127.5*
HYBRID SYSTEMS:
W-87
Min. 15/32-inch
plywood, 24-inch
span
Glasbase Base Sheet, Flintlastic
Base 20, Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra Poly SMS
Base Sheet
FlintFast #12 or #14 with FlintFast 3 in.
Insulation Plate, OMG #14 HD with OMG 3 in.
Round Metal Plate or Trufast #12 DP or #14
HD with Trufast 3” Metal Insulation Plate
6-inch o.c. at 4-inch lap and 6-
inch o.c. in three (3), equally
spaced, staggered center rows
Prime stress
plates with
Karnak #108
SBS-SA-H SBS-AA, SBS-
TA or APP-TA -97.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 17 of 75
TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Primer Roof Cover (Note 15) MDP
(psf) Base Fasteners Attach Base Ply Cap Ply
W-88
Min. 19/32-inch
plywood, 24-inch
span
Glasbase Base Sheet, Flintlastic
Base 20, Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra Poly SMS
Base Sheet
Note 2
7-inch o.c. at 3-inch lap and 7-
inch o.c. in three (3), equally
spaced, staggered center rows
None SBS-SA-H SBS-AA, SBS-
TA or APP-TA -105.0
W-89
Min. 15/32-inch
plywood, 24-inch
span
Glasbase Base Sheet, Flintlastic
Base 20, Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra Poly SMS
Base Sheet
FlintFast #12 or #14 with FlintFast 3 in.
Insulation Plate, OMG #14 HD with OMG 3 in.
Round Metal Plate or Trufast #12 DP or #14
HD with Trufast 3” Metal Insulation Plate
6-inch o.c. at 4-inch lap and 6-
inch o.c. in four (4), equally
spaced, staggered center rows
Prime stress
plates with
Karnak #108
SBS-SA-H SBS-AA, SBS-
TA or APP-TA -127.5
CONVENTIONAL SYSTEMS:
W-90
Min. 23/32-inch
plywood, 24-inch
span
Glasbase Base Sheet, All
Weather/Empire Base Sheet,
Flintlastic Base 20
Note 2
12-inch o.c. at 4-inch lap and 36-
inch o.c. in two (2), equally
spaced, staggered center rows
None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA, SBS-
TA or APP-TA -30.0*
W-91
Min. 23/32-inch
plywood, 24-inch
span
Glasbase Base Sheet, All
Weather/Empire Base Sheet,
Flintlastic Base 20
Note 2
12-inch o.c. at 4-inch lap and 24-
inch o.c. in two (2), equally
spaced, staggered center rows
None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
W-92
Min. 23/32-inch
plywood, 24-inch
span
Flintlastic Poly SMS Base Sheet,
Flintlastic Ultra Poly SMS Base
Sheet
Note 2
12-inch o.c. at 4-inch lap and 36-
inch o.c. in two (2), equally
spaced, staggered center rows
None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
W-93
Min. 15/32-inch
plywood, 24-inch
span
Glasbase Base Sheet, Flintlastic
Base 20, Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra Poly SMS
Base Sheet
FlintFast #12 or #14 with FlintFast 3 in.
Insulation Plate, OMG #14 HD with OMG 3 in.
Round Metal Plate or Trufast #12 DP or #14
HD with Trufast 3” Metal Insulation Plate
6-inch o.c. at 4-inch lap and 6-
inch o.c. in three (3), equally
spaced, staggered center rows
None
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA, SBS-
TA or APP-TA -97.5
W-94
Min. 15/32-inch
plywood, 24-inch
span
Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal
Plates
6-inch o.c. at 4-inch lap and 6-
inch o.c. in three (3), equally
spaced, staggered center rows.
None APP-TA APP-TA -97.5
W-95
Min. 15/32-inch
plywood, 24-inch
span
Glasbase Base Sheet, Flintlastic
Base 20, All Weather/Empire Base
Sheet, Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra Poly SMS
Base Sheet
FlintFast #14 with FlintFast 3 in. Insulation
Plate or Trufast #14 HD with Trufast 3” Metal
Insulation Plate
8-inch o.c. at 4-inch lap and 8-
inch o.c. at three (3) equally
spaced, staggered center rows
None
(Optional)
BP-AA, SBS-
AA or SBS-TA
SBS-AA or
SBS-TA -97.5
W-96
Min. 19/32-inch
plywood, 24-inch
span
Glasbase Base Sheet, Flintlastic
Base 20, Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra Poly SMS
Base Sheet
Note 2
7-inch o.c. at 3-inch lap and 7-
inch o.c. in three (3), equally
spaced, staggered center rows
None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA, SBS-
TA or APP-TA -105.0
W-97
Min. 19/32-inch
plywood, 24-inch
span
Flintlastic APP Base T Dekfast DF-#14-PH3 with PLT-H-2-7/8 or OMG
#14 HD with OMG 3 in. Round Metal Plate
7-inch o.c. at 3-inch lap and 7-
inch o.c. in three (3), equally
spaced, staggered center rows
None APP-TA APP-TA -105.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 18 of 75
TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Primer Roof Cover (Note 15) MDP
(psf) Base Fasteners Attach Base Ply Cap Ply
W-98
Min. 15/32-inch
plywood, 24-inch
span
Glasbase Base Sheet, Flintlastic
Base 20, Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra Poly SMS
Base Sheet
FlintFast #12 or #14 with FlintFast 3 in.
Insulation Plate, OMG #14 HD with OMG 3 in.
Round Metal Plate or Trufast #12 DP or #14
HD with Trufast 3” Metal Insulation Plate
6-inch o.c. at 4-inch lap and 6-
inch o.c. in four (4), equally
spaced, staggered center rows
None
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA, SBS-
TA or APP-TA -127.5
W-99
Min. 15/32-inch
plywood, 24-inch
span
Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal
Plates
6-inch o.c. at 4-inch lap and 6-
inch o.c. in four (4), equally
spaced, staggered center rows.
None APP-TA APP-TA -127.5
COLD-APPLIED SYSTEMS:
W-100
Min. 15/32-inch
plywood, 24-inch
span
Glasbase Base Sheet, Flintlastic
Base 20, All Weather/Empire Base
Sheet, Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra Poly SMS
Base Sheet
FlintFast #12 or #14 with FlintFast 3 in.
Insulation Plate or Trufast #12 DP or #14 HD
with Trufast 3” Metal Insulation Plate
8-inch o.c. at 4-inch lap and 8-
inch o.c. in three (3), equally
spaced, staggered center rows
None (Optional)
SBS-CA1 SBS-CA1 -52.5
TABLE 1H: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System
No.
Deck
(Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply
W-101 APA rated, min. 7/16 CAT, 0.418 in., Exposure 1, OSB
sheathing, 24-inch span
FlintPrime QD, Karnak #108
or ASTM D41 primer
Flintlastic SA Mid Ply,
self-adhering (Optional) SBS-SA SBS-SA -90.0
W-102 Min. 15/32-inch plywood, 24-inch span FlintPrime QD, Karnak #108
or ASTM D41 primer SBS-SA-H (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -112.5
W-103 Min. 15/32-inch plywood, 24-inch span FlintPrime QD, Karnak #108
or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -127.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 19 of 75
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasteners Attach Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
SELF-ADHERING SYSTEMS:
S-1
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard ISO, ENRGY
3, H-Shield, FlintBoard
ISOH
Note 2 1 per 4.0
ft2
Optional min. 1.5-inch
additional layer(s) base
insulation, followed by
min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
hot asphalt,
FlintFast QS,
Insta Stik QS,
OB500, Polyset
Board-Max,
Polyset CR-20
SBS-SA (Optional) SBS-SA SBS-SA -37.5*
S-2
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY 3, H-Shield,
FlintBoard ISOH
Note 2 1 per 2.0
ft2
Optional min. 1.5-inch
additional layer(s) base
insulation, followed by
min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
hot asphalt,
FlintFast QS,
Insta Stik QS,
OB500, Polyset
Board-Max,
Polyset CR-20
SBS-SA (Optional) SBS-SA SBS-SA -45.0*
HYBRID SYSTEMS:
S-3
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY 3, H-Shield,
FlintBoard ISOH
Note 2 1 per
1.45 ft2
Additional layer(s) base
insulation
hot asphalt,
FlintFast QS,
Insta Stik QS,
OB500, Polyset
Board-Max,
Polyset CR-20
Flintlastic
Ultra Glass
SA
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-37.5
S-4
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY 3, H-Shield,
FlintBoard ISOH
Note 2 1 per
1.45 ft2
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
hot asphalt,
FlintFast QS,
Insta Stik QS,
OB500, Polyset
Board-Max,
Polyset CR-20
Flintlastic
Ultra Glass
SA
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
S-5
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
ISOH.
FlintFast #12 or #14 with
FlintFast 3” Insulation Plates
1 per
1.45 ft2
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield
or FlintBoard ISOH.
hot asphalt,
FlintFast QS,
FlintFast LV,
Insta Stik QS,
OB500
SBS-SA-H (Optional) APP-
TA APP-TA -67.5
S-6
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
ISOH
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation
Plate or Trufast #12 DP (steel
only) or #14 HD with Trufast 3”
Metal Insulation Plate
1 per 1.6
ft2
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
FlintFast QS,
FlintFast LV,
Insta Stik QS,
OB500
SBS-SA-H (Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -75.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 20 of 75
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasteners Attach Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
S-7
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ENRGY 3
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation
Plate or Trufast #12 DP (steel
only) or #14 HD with Trufast 3”
Metal Insulation Plate
1 per 1.0
ft2
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof
Board
OB500, 4-inch
o.c. SBS-SA-H (Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -90.0*
CONVENTIONAL SYSTEMS:
S-8
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard ISO, ENRGY
3, H-Shield, FlintBoard
ISOH
Note 2 1 per 4.0
ft2
Optional min. 1.5-inch
additional layer(s) base
insulation, followed by
min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
hot asphalt,
FlintFast QS,
Insta Stik QS,
OB500, Polyset
Board-Max,
Polyset CR-20
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-37.5*
S-9
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY 3, H-Shield,
FlintBoard ISOH
Note 2 1 per 2.0
ft2
Optional min. 1.5-inch
additional layer(s) base
insulation, followed by
min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation, min.
0.75-inch FescoBoard
(homogeneous).
hot asphalt BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-10
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY 3, H-Shield,
FlintBoard ISOH
Note 2 1 per 2.0
ft2
Optional min. 1.5-inch
additional layer(s) base
insulation, followed by
min. 0.25-inch DensDeck
or DensDeck Prime
hot asphalt
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-11
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY 3, H-Shield,
FlintBoard ISOH
Note 2 1 per 2.0
ft2
Optional min. 1.5-inch
additional layer(s) base
insulation, followed by
min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
hot asphalt,
FlintFast QS,
Insta Stik QS,
OB500, Polyset
Board-Max,
Polyset CR-20
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-12
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard ISO, ENRGY
3, H-Shield, FlintBoard
ISOH
Note 2 1 per 3.2
ft2
Optional min. 1.5-inch
additional layer(s) base
insulation, followed by
min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation, min.
0.75-inch FescoBoard
(homogeneous).
hot asphalt BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 21 of 75
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasteners Attach Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
S-13
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard ISO, ENRGY
3, H-Shield, FlintBoard
ISOH
Note 2 1 per 3.2
ft2
Optional min. 1.5-inch
additional layer(s) base
insulation, followed by
min. 0.25-inch DensDeck
or DensDeck Prime
hot asphalt
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-14
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY 3, Multi-Max
FA3
Note 2 1 per 1.3
ft2
Min. 0.75-inch
FescoBoard
(homogeneous)
hot asphalt BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-52.5
S-15
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard ISO, ENRGY
3, H-Shield, FlintBoard
ISOH
Note 2 1 per 1.6
ft2
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
hot asphalt,
FlintFast QS,
Insta Stik QS,
OB500, Polyset
Board-Max,
Polyset CR-20
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
S-16
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY 3, Multi-Max
FA3
Note 2 1 per 1.3
ft2
Min. 0.5-inch Structodek
High Density Fiberboard hot asphalt BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-67.5
S-17
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
ISOH
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation
Plate or Trufast #12 DP (steel
only) or #14 HD with Trufast 3”
Metal Insulation Plate
1 per 1.6
ft2
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
FlintFast QS,
FlintFast LV,
Insta Stik QS,
OB500
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-75.0
S-18
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ENRGY 3
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation
Plate or Trufast #12 DP (steel
only) or #14 HD with Trufast 3”
Metal Insulation Plate
1 per 1.0
ft2
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof
Board
OB500, 4-inch
o.c.
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-90.0*
COLD-APPLIED SYSTEMS:
S-19
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard ISO, H-
Shield or FlintBoard
ISOH
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation
Plate or Trufast #12 DP (steel
only) or #14 HD with Trufast 3”
Metal Insulation Plate
1 per 2.0
ft2
Min. 1.5-inch ACFoam III,
FlintBoard Iso Cold, H-
Shield CG or FlintBoard
Iso ColdH
OB500 or
Polyset CR-20 SBS-CA1 None SBS-CA1 -45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 22 of 75
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasteners Attach Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
S-20
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard ISO, H-
Shield or FlintBoard
ISOH
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation
Plate or Trufast #12 DP (steel
only) or #14 HD with Trufast 3”
Metal Insulation Plate
1 per 2.0
ft2
Optional min. 1.5-inch
additional layer(s) base
insulation, followed by
min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
Insta Stik QS,
FlintFast QS,
FlintFast LV,
OB500, Polyset
Board-Max or
Polyset CR-20
SBS-CA1 None SBS-CA1 -45.0*
S-21
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 2-inch ACFoam II,
FlintBoard ISO, H-
Shield or FlintBoard
ISOH
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation
Plate or Trufast #12 DP (steel
only) or #14 HD with Trufast 3”
Metal Insulation Plate
1 per 2.0
ft2
Optional min. 1.5-inch
additional layer(s) base
insulation, followed by
min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
Insta Stik QS,
FlintFast QS,
FlintFast LV,
OB500, Polyset
Board-Max or
Polyset CR-20
SBS-CA4 None SBS-CA4 -45.0*
S-22
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
ISOH
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation
Plate or Trufast #12 DP (steel
only) or #14 HD with Trufast 3”
Metal Insulation Plate
1 per 1.6
ft2
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
FlintFast QS,
FlintFast LV,
Insta Stik QS,
OB500
SBS-CA1 None SBS-CA1 -75.0
S-23
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch ENRGY 3
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation
Plate or Trufast #12 DP (steel
only) or #14 HD with Trufast 3”
Metal Insulation Plate
1 per 1.0
ft2
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof
Board
OB500, 4-inch
o.c. SBS-CA1 None SBS-CA1 -90.0*
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer(s) Top Insulation Layer Primer Roof Cover (Note 15) MDP
(psf) Type Fasteners Attach Base Ply Ply Cap Ply
SELF-ADHERING SYSTEMS:
S-24
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
Note 2 1 per
3.2 ft2 None SBS-SA (Optional) SBS-
SA SBS-SA -30.0*
S-25
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation Plate
or Trufast #12 DP (steel only) or
#14 HD with Trufast 3” Metal
Insulation Plate
1 per
2.7 ft2 None SBS-SA (Optional) SBS-
SA SBS-SA -37.5*
S-26
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 3/8-inch
SECUROCK Gypsum-
Fiber Roof Board
Note 2 1 per
2.7 ft2 None SBS-SA (Optional) SBS-
SA SBS-SA -45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 23 of 75
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer(s) Top Insulation Layer Primer Roof Cover (Note 15) MDP
(psf) Type Fasteners Attach Base Ply Ply Cap Ply
S-27
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch
DensDeck Note 2 1 per
1.3 ft2
FlintPrime QD,
Karnak #108 or
ASTM D41
primer
SBS-SA (Optional) SBS-
SA SBS-SA -45.0
S-28
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch
FlintBoard ISO
FlintFast #14 with FlintFast 3 in.
Insulation Plate or Trufast #14 HD
with Trufast 3” Metal Insulation
Plate
1 per
1.8 ft2
ASTM D41 or
Karnak #108
Asphalt Primer
SBS-SA (Optional) SBS-
SA SBS-SA -67.5
S-29
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #14 with FlintFast 3 in.
Insulation Plate or Trufast #14 HD
with Trufast 3” Metal Insulation
Plate
1 per
1.6 ft2
ASTM D41 or
Karnak #108
Asphalt Primer
SBS-SA (Optional) SBS-
SA SBS-SA -82.5
S-30
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch
FlintBoard ISO,
FlintBoard H ISO,
ACFoam II or H-Shield
FlintFast #15 (steel only) or
FlintFast #14 (concrete only) with
FlintFast 3 in. Insulation Plate or
Trufast #15 EHD (steel only) or
Trufast #14 HD (concrete only) with
Trufast 3” Metal Insulation Plate
1 per
1.0 ft2
ASTM D41 or
Karnak #108
Asphalt Primer
SBS-SA (Optional) SBS-
SA SBS-SA -97.5
HYBRID SYSTEMS:
S-31
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch
DensDeck, DensDeck
Prime
Note 2 1 per
2.0 ft2 None SBS-SA-
H
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-30.0*
S-32
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation Plate
or Trufast #12 DP (steel only) or
#14 HD with Trufast 3” Metal
Insulation Plate
1 per
2.7 ft2 None SBS-SA-
H
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-37.5*
S-33
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 3/8-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation Plate
or Trufast #12 DP (steel only) or
#14 HD with Trufast 3” Metal
Insulation Plate
1 per
2.7 ft2 None SBS-SA-
H
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-34
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch
FlintBoard ISO
FlintFast #14 with FlintFast 3 in.
Insulation Plate or Trufast #14 HD
with Trufast 3” Metal Insulation
Plate
1 per
1.8 ft2 None SBS-SA-
H
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -67.5
S-35
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
ISOH.
FlintFast #12 (steel only) or
FlintFast #14 with FlintFast 3 in.
Insulation Plate or Trufast #12 DP
(steel only) or Trufast #14 HD with
Trufast 3” Metal Insulation Plate
1 per
1.45 ft2 None SBS-SA-
H
(Optional) SBS-
AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-75.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 24 of 75
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer(s) Top Insulation Layer Primer Roof Cover (Note 15) MDP
(psf) Type Fasteners Attach Base Ply Ply Cap Ply
S-36
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #14 with FlintFast 3 in.
Insulation Plate or Trufast #14 HD
with Trufast 3” Metal Insulation
Plate
1 per
1.6 ft2 None SBS-SA-
H
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -82.5
S-37
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation Plate
or Trufast #12 DP (steel only) or
#14 HD with Trufast 3” Metal
Insulation Plate
1 per
1.45 ft2 None SBS-SA-
H
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -82.5
S-38
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam
II, FlintBoard ISO,
ENRGY 3 or Multi-Max
FA3
Note 2 1 per
1.3 ft2 None SBS-SA-
H
(Optional) SBS-
AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-82.5
S-39
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch
FlintBoard ISO,
FlintBoard H ISO,
ACFoam II or H-Shield
FlintFast #15 (steel only) or
FlintFast #14 (concrete only) with
FlintFast 3 in. Insulation Plate or
Trufast #15 EHD (steel only) or
Trufast #14 HD (concrete only) with
Trufast 3” Metal Insulation Plate
1 per
1.0 ft2 None SBS-SA-
H
(Optional) SBS-
AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-97.5
S-40
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation Plate
or Trufast #12 DP (steel only) or
#14 HD with Trufast 3” Metal
Insulation Plate
1 per
1.0 ft2 None SBS-SA-
H
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -135.0
CONVENTIONAL SYSTEMS:
S-41
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.75-inch
FescoBoard
(homogeneous)
Note 2 1 per
2.7 ft2 None BP-AA,
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-30.0*
S-42
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation
Note 2 1 per
4.0 ft2 None BP-AA,
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-37.5*
S-43
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
Note 2 1 per
4.0 ft2 None BP-AA,
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-37.5*
S-44
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
Note 2 1 per
4.0 ft2 None
BP-AA,
SBS-AA,
SBS-TA
or APP-
TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 25 of 75
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer(s) Top Insulation Layer Primer Roof Cover (Note 15) MDP
(psf) Type Fasteners Attach Base Ply Ply Cap Ply
S-45
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation, min.
0.75-inch FescoBoard
(homogeneous)
Note 2 1 per
2.0 ft2 None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-46
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch
DensDeck or
DensDeck Prime
Note 2 1 per
2.0 ft2 None
BP-AA,
SBS-AA,
SBS-TA
or APP-
TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
S-47
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional for Concrete or
Recover) Min. 1.5-inch,
One or more layers, any
combination, loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or
FlintFast #14 with FlintFast 3 in.
Insulation Plate or Trufast #12 DP
(steel only) or Trufast #14 HD with
Trufast 3” Metal Insulation Plate
1 per
1.45 ft2 None APP-TA (Optional) APP-
TA APP-TA -60.0
S-48
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional for Concrete or
Recover) Min. 2-inch
ACFoam II, FlintBoard, H-
Shield or ENRGY 3, loose
laid.
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
Note 2 1 per
1.8 ft2 None
BP-AA,
SBS-AA,
SBS-TA
or APP-
TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
S-49
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation Plate
or Trufast #12 DP (steel only) or
#14 HD with Trufast 3” Metal
Insulation Plate
1 per
1.45 ft2 None
BP-AA,
SBS-AA,
SBS-TA
or APP-
TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-82.5
S-50
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional for Concrete or
Recover) Min. 1.5-inch
ACFoam II, FlintBoard, H-
Shield
Min. 0.5-inch
DensDeck Prime
FlintFast #14 with FlintFast 3 in.
Insulation Plate or Trufast #14 HD
with Trufast 3” Metal Insulation
Plate
1 per
1.3 ft2 None BP-AA,
SBS-AA
(Optional) BP-
AA, SBS-AA SBS-AA -112.5
S-51
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation Plate
or Trufast #12 DP (steel only) or
#14 HD with Trufast 3” Metal
Insulation Plate
1 per
1.0 ft2 None
BP-AA,
SBS-AA,
SBS-TA
or APP-
TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-135.0
S-52
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional for Concrete or
Recover) Min. 1.5-inch
ACFoam II, FlintBoard, H-
Shield
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #14 with FlintFast 3 in.
Insulation Plate or Trufast #14 HD
with Trufast 3” Metal Insulation
Plate
1 per
1.3 ft2 None BP-AA,
SBS-AA
(Optional) BP-
AA, SBS-AA SBS-AA -157.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 26 of 75
TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer(s) Top Insulation Layer Primer Roof Cover (Note 15) MDP
(psf) Type Fasteners Attach Base Ply Ply Cap Ply
S-53
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional for Concrete or
Recover) Min. 1.5-inch
ACFoam II, FlintBoard, H-
Shield
Min. 0.5-inch
DensDeck Prime
FlintFast #14 with FlintFast 3 in.
Insulation Plate or Trufast #14 HD
with Trufast 3” Metal Insulation
Plate
1 per
1.0 ft2 None BP-AA,
SBS-AA
(Optional) BP-
AA, SBS-AA SBS-AA -157.5
S-54
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional for Concrete or
Recover) Min. 1.5-inch
ACFoam II, FlintBoard, H-
Shield
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #14 with FlintFast 3 in.
Insulation Plate or Trufast #14 HD
with Trufast 3” Metal Insulation
Plate
1 per
1.0 ft2 None BP-AA,
SBS-AA
(Optional) BP-
AA, SBS-AA SBS-AA -172.5
COLD-APPLIED SYSTEMS:
S-55
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation Plate
or Trufast #12 DP (steel only) or
#14 HD with Trufast 3” Metal
Insulation Plate
1 per
2.7 ft2 None SBS-CA1 None SBS-CA1 -37.5*
S-56
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation Plate
or Trufast #12 DP (steel only) or
#14 HD with Trufast 3” Metal
Insulation Plate
1 per
2.7 ft2 None SBS-CA4 None SBS-CA4 -37.5*
S-57
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch ACFoam
III, FlintBoard Iso Cold,
H-Shield CG or
FlintBoard Iso ColdH
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation Plate
or Trufast #12 DP (steel only) or
#14 HD with Trufast 3” Metal
Insulation Plate
1 per
2.0 ft2 None SBS-CA1 None SBS-CA1 -45.0*
S-58
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 3/8-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation Plate
or Trufast #12 DP (steel only) or
#14 HD with Trufast 3” Metal
Insulation Plate
1 per
2.7 ft2 None SBS-CA1 None SBS-CA1 -45.0*
S-59
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 3/8-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation Plate
or Trufast #12 DP (steel only) or
#14 HD with Trufast 3” Metal
Insulation Plate
1 per
2.7 ft2 None SBS-CA4 None SBS-CA4 -45.0*
S-60
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast #12 (steel only) or #14
with FlintFast 3 in. Insulation Plate
or Trufast #12 DP (steel only) or
#14 HD with Trufast 3” Metal
Insulation Plate
1 per
1.45 ft2 None SBS-CA1 None SBS-CA1 -82.5*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 27 of 75
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Attach Type Fasteners Attach Base Ply Cap Ply
SELF-ADHERING SYSTEMS:
S-61
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached Flintlastic SA NailBase Note 2
9-inch o.c. at min. 2-inch lap and
18-inch o.c. in two (2), equally
spaced, staggered center rows
(Optional) SBS-
SA SBS-SA -45.0*
S-62
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached Flintlastic SA NailBase Note 2
12-inch o.c. at min. 2-inch lap and
12-inch o.c. in two (2), equally
spaced, staggered center rows
(Optional) SBS-
SA SBS-SA -52.5*
S-63
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached Flintlastic SA NailBase Note 2
12-inch o.c. at min. 4-inch lap and
12-inch o.c. in two (2), equally
spaced, staggered center rows
(Optional) SBS-
SA SBS-SA -60.0*
S-64
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Flintlastic SA NailBase (laid
parallel to deck flutes) Note 2
8-inch o.c. at min. 4-inch lap and 8-
inch o.c. in two (2), equally spaced,
staggered center rows, ASTM D41
primer at plates
(Optional) SBS-
SA SBS-SA -82.5*
CONVENTIONAL SYSTEMS:
S-65
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Glasbase Base Sheet, All
Weather/Empire Base
Sheet, Flintlastic Base 20
Note 2
12-inch o.c. at 4-inch lap and 36-
inch o.c. in two (2), equally spaced,
staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -30.0*
S-66
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Glasbase Base Sheet, All
Weather/Empire Base
Sheet, Flintlastic Base 20
Note 2
12-inch o.c. at 4-inch lap and 24-
inch o.c. in two (2), equally spaced,
staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -45.0*
S-67
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra Poly
SMS Base Sheet
Note 2
12-inch o.c. at 4-inch lap and 36-
inch o.c. in two (2), equally spaced,
staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -45.0*
S-68
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra Poly
SMS Base Sheet
Note 2
18-inch o.c. at 4-inch lap and 18-
inch o.c. in one (1) staggered
center row
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -45.0*
S-69
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra Poly
SMS Base Sheet
Dekfast DF-#14-PH3
with PLT-R-2-4B
12-inch o.c. within the min. 4-inch
wide, heat-welded side lap
SBS-AA, SBS-TA
or APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
S-70
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet, Flintlastic Poly SMS
Base Sheet
Note 2
12-inch o.c. at 3-inch lap and 12-
inch o.c. in two (2), equally spaced,
staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -52.5
S-71
Min. 22 ga., type B, 40 ksi
steel or min. 2,500 psi
structrual concrete
Min. 2-inch, One or
more layers, any
combination
Prelim.
Attached
Flintlastic Ultra Poly SMS
Base Sheet
Trufast #15 EHD (steel only)
or Trufast #14 HD (concrete
only) with Trufast 2” Barbed
Metal Seam Plate
12-inch o.c. within the min. 4-inch
wide, heat-welded side lap
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -52.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 28 of 75
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Attach Type Fasteners Attach Base Ply Cap Ply
S-72
Min. 22 ga., type B, Grade
80 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Flintlastic Ultra Poly SMS
Base Sheet
Trufast #15 EHD (steel only)
or Trufast #14 HD (concrete
only) with Trufast 2.4”
Barbed Metal Seam Plate
12-inch o.c. within the min. 4-inch
wide, heat-welded side lap
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -60.0
S-73
Min. 22 ga., type B, 40 ksi
steel or min. 2,500 psi
structrual concrete
Min. 2-inch, One or
more layers, any
combination
Prelim.
Attached
Flintlastic Ultra Poly SMS
Base Sheet
Trufast #15 EHD (steel only)
or Trufast #14 HD (concrete
only) with Trufast 2.4”
Scoop Seam Plate
12-inch o.c. within the min. 4-inch
wide, heat-welded side lap
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -67.5
S-74
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached Glasbase Base Sheet
OMG #14 HD with OMG
Flat Bottom Plates
(AccuTrac)
6-inch o.c. at 4-inch lap and 6-inch
o.c. in two (2), equally spaced,
staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -67.5
S-75
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached Flintlastic Base 20 Note 2
6-inch o.c. at 4-inch lap and 6-inch
o.c. in two (2), equally spaced,
staggered center rows
BP-AA, SBS-AA,
SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -67.5
S-76
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attach
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet, Flintlastic Poly SMS
Base Sheet, Flintlastic Ultra
Poly SMS Base Sheet
FlintFast #14 with FlintFast
3 in. Insulation Plate or
Trufast #14 HD with Trufast
3” Metal Insulation Plate
6-inch o.c. at 4-inch lap and 6-inch
o.c. at three (3) equally spaced,
staggered center rows
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -97.5
S-77
Min. 22 ga., type B, 40 ksi
steel or min. 2,500 psi
structrual concrete
Min. 2-inch, One or
more layers, any
combination
Prelim.
Attached
Flintlastic Ultra Poly SMS
Base Sheet
Trufast #15 EHD (steel only)
or Trufast #14 HD (concrete
only) with Trufast 2.4”
Scoop Seam Plate
6-inch o.c. within the min. 4-inch
wide, heat-welded side lap
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -112.5
S-78
Min. 22 ga., type B, Grade
80 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra Poly
SMS Base Sheet
Note 2
12-inch o.c. at 4-inch lap and 12-
inch o.c. in two (2), equally spaced,
staggered center rows
SBS-TA or APP-
TA
SBS-TA or
APP-TA -112.5
S-79
Min. 22 ga., type B, Grade
80 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Flintlastic Poly SMS Base
Sheet, Flintlastic Ultra Poly
SMS Base Sheet
Note 2
12-inch o.c. at 4-inch lap and 12-
inch o.c. in two (2), equally spaced,
staggered center rows
SBS-AA SBS-AA or
SBS-TA -120.0
S-80
Min. 22 ga., type B, 40 ksi
steel or min. 2,500 psi
structrual concrete
Min. 2-inch, One or
more layers, any
combination
Prelim.
Attached
Flintlastic Ultra Poly SMS
Base Sheet
Trufast #15 EHD (steel only)
or Trufast #14 HD (concrete
only) with Trufast 2.4”
Scoop Seam Plate
6-inch o.c. within the min. 4-inch
wide, heat-welded side laps and 6-
inch o.c. in one (1) center row,
stripped-in with 6-inch side strips
of torch-applied Flintlastic Poly
SMS Base Sheet or Flintlastic Ultra
Poly SMS Base Sheet.
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -165.0
COLD-APPLIED SYSTEMS:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 29 of 75
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Attach Type Fasteners Attach Base Ply Cap Ply
S-81
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Min. 1.5-inch, One
or more layers, any
combination
Prelim.
Attached
Glasbase Base Sheet, All
Weather/Empire Base
Sheet, Flintlastic Base 20
Note 2
6-inch o.c. at 4-inch lap and 12-
inch o.c. in two (2), equally spaced,
staggered center rows
SBS-CA1 SBS-CA1 -45.0*
S-82
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structrual concrete
Min. 1-inch, One or
more layers, any
combination
Loose-laid
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet, Flintlastic Poly SMS
Base Sheet, Flintlastic Ultra
Poly SMS Base Sheet
FlintFast #14 with FlintFast
3 in. Insulation Plate or
Trufast #14 HD with Trufast
3” Metal Insulation Plate
6-inch o.c. at 4-inch lap and 12-
inch o.c. in three (3), equally
spaced, staggered center rows
(Optional) SBS-
CA1 SBS-CA1 -75.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 30 of 75
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
Sys.
No.
Deck
(Note 1) Primer
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
SELF-ADHERING SYSTEMS:
C-1. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
hot asphalt Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board hot asphalt None SBS-SA (Optional) SBS-
SA SBS-SA -172.5
C-2. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3, Multi-
Max FA3
hot asphalt Min. 0.25-inch DensDeck hot asphalt
FlintPrime QD,
Karnak #108
or ASTM D41
primer
SBS-SA (Optional) SBS-
SA SBS-SA -192.5
C-3. Structural
concrete None
(Optional) Min. 1.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.5-inch ACFoam-HD
CoverBoard or H-Shield HD
FlintFast QS or
FlintFast LV
FlintPrime QD,
Karnak #108
or ASTM D41
primer
SBS-SA (Optional) SBS-
SA SBS-SA -97.5
C-4. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV None SBS-SA (Optional) SBS-
SA SBS-SA -172.5
C-5. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3, Multi-
Max FA3
FlintFast QS or
FlintFast LV Min. 0.25-inch DensDeck FlintFast QS or
FlintFast LV
FlintPrime QD,
Karnak #108
or ASTM D41
primer
SBS-SA (Optional) SBS-
SA SBS-SA -192.5
C-6. Structural
concrete None
(Optional) Min. 1.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV, 6-
inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV, 6-
inch o.c.
ASTM D41 or
Karnak #108
Asphalt
Primer
SBS-SA (Optional) SBS-
SA SBS-SA -315.0
C-7. Structural
concrete None
(Optional) Min. 1.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV, 6-
inch o.c.
Min. 0.5-inch ACFoam-HD
CoverBoard or H-Shield HD
FlintFast QS or
FlintFast LV, 6-
inch o.c.
FlintPrime QD,
Karnak #108
or ASTM D41
primer
SBS-SA (Optional) SBS-
SA SBS-SA -315.0
C-8. Structural
concrete
(Optional)
ASTM D41 or
Karnak #108
Asphalt
Primer
Min. 1.5-inch Multi-Max FA Insta Stik QS Min. 0.25-inch DensDeck Insta Stik QS
FlintPrime QD,
Karnak #108
or ASTM D41
primer
SBS-SA (Optional) SBS-
SA SBS-SA -67.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 31 of 75
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
Sys.
No.
Deck
(Note 1) Primer
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-9. Structural
concrete
(Optional)
ASTM D41 or
Karnak #108
Asphalt
Primer
Min. 1.5-inch ENRGY 3 Insta Stik QS Min. 0.25-inch DensDeck Insta Stik QS
FlintPrime QD,
Karnak #108
or ASTM D41
primer
SBS-SA (Optional) SBS-
SA SBS-SA -112.5
C-10. Structural
concrete
(Optional)
ASTM D41 or
Karnak #108
Asphalt
Primer
Min. 1.5-inch ACFoam II or
FlintBoard Insta Stik QS Min. 0.25-inch DensDeck Insta Stik QS
FlintPrime QD,
Karnak #108
or ASTM D41
primer
SBS-SA (Optional) SBS-
SA SBS-SA -120.0
C-11. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
Insta Stik QS Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Insta Stik QS None SBS-SA (Optional) SBS-
SA SBS-SA -172.5
C-12. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500
FlintPrime QD,
Karnak #108
or ASTM D41
primer
SBS-SA (Optional) SBS-
SA SBS-SA -120.0
C-13. Structural
concrete None Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500
FlintPrime QD,
Karnak #108
or ASTM D41
primer
SBS-SA (Optional) SBS-
SA SBS-SA -150.0
C-14. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS-
SA SBS-SA -172.5
C-15. Structural
concrete None
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H or min.
1.5-inch Multi-Max FA3, Ultra-
Max
Polyset Board-
Max or
Polyset CR-20
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Polyset Board-
Max or
Polyset CR-20
None SBS-SA (Optional) SBS-
SA SBS-SA -172.5
C-16. Structural
concrete None
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H or min.
1.5-inch Multi-Max FA3, Ultra-
Max
Polyset Board-
Max or
Polyset CR-20
Min. 0.25-inch DensDeck
Polyset Board-
Max or
Polyset CR-20
FlintPrime QD,
Karnak #108
or ASTM D41
primer
SBS-SA (Optional) SBS-
SA SBS-SA -192.5
HYBRID SYSTEMS:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 32 of 75
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
Sys.
No.
Deck
(Note 1) Primer
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-17. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
hot asphalt (Optional) Additional
layer(s) base insulation hot asphalt None
Flintlastic
Ultra Glass
SA
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-322.5
C-18. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
hot asphalt (Optional) Additional
layer(s) base insulation hot asphalt None
Black
Diamond
Base Sheet
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-375.0
C-19. Structural
concrete None
(Optional) Min. 1.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.5-inch ACFoam-HD
CoverBoard or H-Shield HD
FlintFast QS or
FlintFast LV None SBS-SA-H
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-97.5
C-20. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS (Optional) Additional
layer(s) base insulation FlintFast QS None SBS-SA-H
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-232.5
C-21. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board FlintFast QS None SBS-SA-H
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-217.5
C-22. Structural
concrete None Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board FlintFast QS None N/A None SBS-SA-H
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-195.0
C-23. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast LV (Optional) Additional
layer(s) base insulation FlintFast LV None SBS-SA-H
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-270.0
C-24. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast LV Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board FlintFast LV None SBS-SA-H
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-217.5
C-25. Structural
concrete None Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board FlintFast LV None N/A None SBS-SA-H
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-195.0
C-26. Structural
concrete None
(Optional) Min. 1.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV, 6-
inch o.c.
Min. 0.25-inch DensDeck
Prime or SECUROCK
Gypsum-Fiber Roof Board
or min. 0.5-inch ACFoam-
HD CoverBoard or H-Shield
HD
FlintFast QS or
FlintFast LV, 6-
inch o.c.
None SBS-SA-H
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-315.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 33 of 75
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
Sys.
No.
Deck
(Note 1) Primer
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-27. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
Insta Stik QS (Optional) Additional
layer(s) base insulation Insta Stik QS None SBS-SA-H
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-135.0
C-28. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
Insta Stik QS Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Insta Stik QS None SBS-SA-H
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-217.5
C-29. Structural
concrete None Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Insta Stik QS None N/A None SBS-SA-H
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-195.0
C-30. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
OB500 (Optional) Additional
layer(s) base insulation OB500 None SBS-SA-H
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-135.0
C-31. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 None SBS-SA-H
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-217.5
C-32. Structural
concrete None Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 None N/A None SBS-SA-H
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-195.0
C-33. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset Board-
Max or
Polyset CR-20
(Optional) Additional
layer(s) base insulation
Polyset Board-
Max or
Polyset CR-20
None SBS-SA-H
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-270.0
C-34. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset Board-
Max or
Polyset CR-20
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Polyset Board-
Max or
Polyset CR-20
None SBS-SA-H
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-217.5
C-35. Structural
concrete None Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Polyset Board-
Max or
Polyset CR-20
None N/A None SBS-SA-H
(Optional) SBS-
AA, SBS-TA, APP-
TA
SBS-AA,
SBS-TA,
APP-TA
-195.0
CONVENTIONAL SYSTEMS:
C-36. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
Min. 1.5-inch ACFoam II or
FlintBoard ISO. hot asphalt Min. 0.25-inch DensDeck,
DensDeck Prime hot asphalt None SBS-TA (Optional) SBS-
TA SBS-TA -180.0
C-37. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
(Optional) Min. 1.5-inch
ACFoam II or FlintBoard ISO. hot asphalt Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board hot asphalt None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-180.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 34 of 75
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
Sys.
No.
Deck
(Note 1) Primer
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-38. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
(Optional) Min. 2-inch ACFoam
II, FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
hot asphalt Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board hot asphalt None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-225.0
C-39. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
(Optional) Min. 1.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
hot asphalt Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board hot asphalt None APP-TA (Optional) APP-
TA APP-TA -252.5
C-40. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
hot asphalt Min. 0.5-inch Structodek
High Density Fiberboard hot asphalt None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-227.0
C-41. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
(Optional) Min. 2-inch ACFoam
II, FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
hot asphalt Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board hot asphalt None SBS-TA or
APP-TA
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -232.5
C-42. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
hot asphalt Min. 0.25-inch DensDeck hot asphalt None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-240.0
C-43. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
Min. 1.5-inch ACFoam II or
FlintBoard ISO hot asphalt Min. 0.75-inch FescoBoard
(homogeneous) hot asphalt None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-412.0
C-44. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
Min. 1.5-inch ACFoam II or
FlintBoard ISO hot asphalt Min. 0.5-inch DuraBoard
(homogeneous) hot asphalt None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-430.0
C-45. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
0.5-inch Structodek High
Density Fiberboard or min. 0.75-
inch Fesco Board
(homogeneous)
hot asphalt None N/A None BP-AA (Optional) BP-AA
or SBS-AA SBS-AA -437.5
C-46. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
0.25-inch DensDeck, DensDeck
Prime or SECUROCK Gypsum-
Fiber Roof Board
hot asphalt None N/A None SBS-TA (Optional) SBS-
AA or SBS-TA
SBS-AA or
SBS-TA -302.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 35 of 75
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
Sys.
No.
Deck
(Note 1) Primer
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-47. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board hot asphalt None N/A None
Flintlastic
Ultra Poly
SMS Base
Sheet,
torched
(Optional)
Flintlastic Ultra
Poly SMS Base
Sheet, torched
SBS-TA -487.5
C-48. Structural
concrete
ASTM D41 or
Karnak #108
Asphalt
Primer
0.25-inch DensDeck, DensDeck
Prime or SECUROCK Gypsum-
Fiber Roof Board
hot asphalt None N/A None BP-AA (Optional) BP-AA
or SBS-AA SBS-AA -537.5
C-49. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
FlintFast QS Min. 0.5-inch Structodek
High Density Fiberboard FlintFast QS None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-127.5
C-50. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
FlintFast LV Min. 0.5-inch Structodek
High Density Fiberboard FlintFast LV None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-180.0
C-51. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
FlintFast QS Min. 0.25-inch DensDeck FlintFast QS None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-232.5
C-52. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
FlintFast LV Min. 0.25-inch DensDeck FlintFast LV None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-240.0
C-53. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast LV Min. 0.25-inch DensDeck
Prime FlintFast LV None BP-AA, SBS-
AA
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -297.5
C-54. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast LV Min. 0.25-inch DensDeck
Prime FlintFast LV None SBS-TA (Optional) SBS-
TA SBS-TA -302.5
C-55. Structural
concrete None
Min. 2-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-225.0
C-56. Structural
concrete None
Min. 2-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV None SBS-TA or
APP-TA
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -232.5
C-57. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV None APP-TA (Optional) APP-
TA APP-TA -252.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 36 of 75
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
Sys.
No.
Deck
(Note 1) Primer
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-58. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV None
BP-AA, SBS-
AA or SBS-
TA
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -297.5
C-59. Structural
concrete None 0.5-inch Structodek High
Density Fiberboard FlintFast LV None N/A None BP-AA, SBS-
AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-195.0
C-60. Structural
concrete None
Min. 0.25-inch DensDeck Prime
or SECUROCK Gypsum-Fiber
Roof Board
FlintFast LV None N/A None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-195.0
C-61. Structural
concrete None
(Optional) Min. 1.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV, 6-
inch o.c.
Min. 0.25-inch DensDeck
Prime or SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV, 6-
inch o.c.
None SBS-AA or
SBS-TA
(Optional) SBS-
AA or SBS-TA
SBS-AA or
SBS-TA -315.0
C-62. Structural
concrete None
(Optional) Min. 1.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV, 6-
inch o.c.
Min. 0.25-inch DensDeck
Prime or SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV, 6-
inch o.c.
None
Flintlastic
STA or
Flintlastic
STA Plus
(Optional) APP-
TA APP-TA -315.0
C-63. Structural
concrete None Min. 1.5-inch ACFoam II or
FlintBoard ISO. Insta Stik QS Min. 0.25-inch DensDeck Insta Stik QS None SBS-TA (Optional) SBS-
TA SBS-TA -112.5
C-64. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
Insta Stik QS Min. 0.25-inch DensDeck
Prime Insta Stik QS None BP-AA, SBS-
AA
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -297.5
C-65. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
Insta Stik QS Min. 0.25-inch DensDeck
Prime Insta Stik QS None SBS-TA (Optional) SBS-
TA SBS-TA -302.5
C-66. Structural
concrete None
Min. 2-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
Insta Stik QS Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Insta Stik QS None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-225.0
C-67. Structural
concrete None
Min. 2-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
Insta Stik QS Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Insta Stik QS None SBS-TA or
APP-TA
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -232.5
C-68. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
Insta Stik QS Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Insta Stik QS None APP-TA (Optional) APP-
TA APP-TA -252.5
C-69. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
Insta Stik QS Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Insta Stik QS None
BP-AA, SBS-
AA or SBS-
TA
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -297.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 37 of 75
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
Sys.
No.
Deck
(Note 1) Primer
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-70. Structural
concrete None 0.5-inch Structodek High
Density Fiberboard Insta Stik QS None N/A None BP-AA, SBS-
AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-195.0
C-71. Structural
concrete None Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Insta Stik QS None N/A None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-195.0
C-72. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
OB500 Min. 0.5-inch Structodek
High Density Fiberboard OB500 None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-120.0
C-73. Structural
concrete None Min. 1.5-inch ACFoam II or
FlintBoard ISO. OB500 Min. 0.25-inch DensDeck
or DensDeck Prime OB500 None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-150.0
C-74. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
OB500 Min. 0.25-inch DensDeck
Prime OB500 None
BP-AA, SBS-
AA or SBS-
TA
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -297.5
C-75. Structural
concrete None
Min. 2-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-225.0
C-76. Structural
concrete None
Min. 2-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 None SBS-TA or
APP-TA
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -232.5
C-77. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 None APP-TA (Optional) APP-
TA APP-TA -252.5
C-78. Structural
concrete None
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 None
BP-AA, SBS-
AA or SBS-
TA
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -297.5
C-79. Structural
concrete None 0.5-inch Structodek High
Density Fiberboard OB500 None N/A None BP-AA, SBS-
AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-195.0
C-80. Structural
concrete None Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 None N/A None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-195.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 38 of 75
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
Sys.
No.
Deck
(Note 1) Primer
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-81. Structural
concrete None
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H or min.
1.5-inch Multi-Max FA3, Ultra-
Max
Polyset Board-
Max or
Polyset CR-20
Min. 0.5-inch Structodek
High Density Fiberboard Polyset CR-20 None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-180.0
C-82. Structural
concrete None
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H, min. 1.3-
inch ACFoam III, FlintBoard ISO
Cold or min. 1.5-inch Multi-Max
FA3, Ultra-Max
Polyset Board-
Max or
Polyset CR-20
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Polyset Board-
Max or
Polyset CR-20
None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-225.0
C-83. Structural
concrete None
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H or min.
1.5-inch Multi-Max FA3, Ultra-
Max
Polyset Board-
Max or
Polyset CR-20
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Polyset Board-
Max or
Polyset CR-20
None SBS-TA or
APP-TA
(Optional) SBS-
TA or APP-TA
SBS-TA or
APP-TA -232.5
C-84. Structural
concrete None
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H or min.
1.5-inch Multi-Max FA3, Ultra-
Max
Polyset Board-
Max or
Polyset CR-20
Min. 0.25-inch DensDeck
Polyset Board-
Max or
Polyset CR-20
None BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-240.0
C-85. Structural
concrete None 0.5-inch Structodek High
Density Fiberboard
Polyset Board-
Max or
Polyset CR-20
None N/A None BP-AA, SBS-
AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-195.0
C-86. Structural
concrete None Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Polyset Board-
Max or
Polyset CR-20
None N/A None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-195.0
COLD-APPLIED SYSTEMS:
C-87. Structural
concrete None
(Optional) Min. 1.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.25-inch DEXcell FA
Glass Mat Roof Board
FlintFast QS or
FlintFast LV None
Flintlastic
Poly SMS
Base Sheet
in Karnak
#81
(Optional)
Flintlastic Poly
SMS Base Sheet
in Karnak #81
SBS-CA1 -90.0
C-88. Structural
concrete None
(Optional) Min. 1.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.5-inch ACFoam-HD
CoverBoard or H-Shield HD
FlintFast QS or
FlintFast LV None SBS-CA1 None SBS-CA1 -97.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 39 of 75
TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
Sys.
No.
Deck
(Note 1) Primer
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-89. Structural
concrete None
(Optional) Min. 1.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.5-inch ACFoam-HD
CoverBoard or H-Shield HD
FlintFast QS or
FlintFast LV None SBS-CA4 None SBS-CA4 -97.5
C-90. Structural
concrete None
Min. 0.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV None SBS-CA1 None SBS-CA1 -105.0
C-91. Structural
concrete None
Min. 0.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV None SBS-CA4 None SBS-CA4 -105.0
C-92. Structural
concrete None
(Optional) Min. 1.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV, 6-
inch o.c.
Min. 0.25-inch DEXcell FA
Glass Mat Roof Board
FlintFast QS or
FlintFast LV, 6-
inch o.c.
None
Flintlastic
Poly SMS
Base Sheet
in Karnak
#81
(Optional)
Flintlastic Poly
SMS Base Sheet
in Karnak #81
SBS-CA1 -112.5
C-93. Structural
concrete None
(Optional) Min. 0.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
OB500
Min. 1.5-inch ACFoam III,
FlintBoard Iso Cold, H-
Shield CG or FlintBoard Iso
ColdH
OB500 None SBS-CA1 None SBS-CA1 -82.5
C-94. Structural
concrete None
Min. 0.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 None SBS-CA1 None SBS-CA1 -105.0
C-95. Structural
concrete None
Min. 0.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 None SBS-CA4 None SBS-CA4 -105.0
C-96. Structural
concrete None
(Optional) Min. 0.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
Polyset Board-
Max or
Polyset CR-20
Min. 1.5-inch ACFoam III,
FlintBoard Iso Cold, H-
Shield CG or FlintBoard Iso
ColdH
Polyset Board-
Max or
Polyset CR-20
None SBS-CA1 None SBS-CA1 -82.5
C-97. Structural
concrete None
Min. 0.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset Board-
Max or
Polyset CR-20
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Polyset Board-
Max or
Polyset CR-20
None SBS-CA1 None SBS-CA1 -105.0
C-98. Structural
concrete None
Min. 0.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset Board-
Max or
Polyset CR-20
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Polyset Board-
Max or
Polyset CR-20
None SBS-CA4 None SBS-CA4 -105.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 40 of 75
TABLE 3B: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-3: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Primer Temp Roof
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15)
MDP (psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
COLD-APPLIED SYSTEMS:
C-99. Structural
concrete
FlintPrime QD,
Karnak #108
or ASTM D41
Flintlastic SA
PlyBase, self-
adhered
(Optional) Min. 0.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
OB500
Min. 1.5-inch ACFoam III,
FlintBoard Iso Cold, H-Shield CG
or FlintBoard Iso ColdH
OB500 SBS-CA1 None SBS-CA1 -82.5
C-100. Structural
concrete
FlintPrime QD,
Karnak #108
or ASTM D41
Flintlastic SA
PlyBase, self-
adhered
Min. 0.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -82.5
C-101. Structural
concrete
FlintPrime QD,
Karnak #108
or ASTM D41
Flintlastic SA
PlyBase, self-
adhered
Min. 0.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-CA4 None SBS-CA4 -82.5
TABLE 3C: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System
No.
Deck
(Note 1) Primer Roof Cover (Note 15) MDP
(psf) Base Ply Ply Cap Ply
SELF-ADHERING SYSTEMS:
C-102. Structural concrete FlintPrime QD, Karnak #108 or ASTM D41 SBS-SA (Optional) SBS-SA SBS-SA -630.0
HYBRID SYSTEMS:
C-103. Structural concrete Karnak #108 Asphalt Primer Flintlastic Ultra Glass SA (Optional) SBS-AA SBS-AA -135.0
C-104. Structural concrete FlintPrime QD, Karnak #108 or ASTM D41 SBS-SA-H (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -150.0
C-105. Structural concrete Karnak #108 Asphalt Primer Flintlastic Ultra Glass SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5
C-106. Structural concrete FlintPrime QD, Karnak #108 or ASTM D41 SBS-SA-H (Optional) BP-AA, SBS-AA SBS-AA -240.0
C-107. Structural concrete FlintPrime QD, Karnak #108 or ASTM D41 BP-AA, SBS-AA SBS-SA-H SBS-AA, SBS-TA, APP-TA -635.0
CONVENTIONAL SYSTEMS:
C-108. Structural concrete Karnak #108 Asphalt Primer APP-TA (Optional) APP-TA APP-TA -420.0
C-109. Structural concrete FlintPrime QD, Karnak #108 or ASTM D41 SBS-TA (Optional) SBS-TA SBS-TA -542.5
C-110. Structural concrete FlintPrime QD, Karnak #108 or ASTM D41 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -635.0
COLD-APPLIED SYSTEMS:
C-111. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer SBS-CA1 (Optional) SBS-CA1 SBS-CA1 -262.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 41 of 75
TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
LWIC
(Note 14)
Base Insulation Layer Coverboard Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
CELCORE (FL2037):
SELF-ADHERING SYSTEMS:
LWC-1
Min. 22 ga.,
Type BV, Grade
33 steel, 6 ft
span
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
FlintFast QS
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast QS SBS-SA (Optional) SBS-
SA SBS-SA -52.5
LWC-2
Min. 22 ga.,
Type BV, Grade
33 steel, 6 ft
span
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
FlintFast LV
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast LV SBS-SA (Optional) SBS-
SA SBS-SA -52.5
LWC-3
Min. 22 ga.,
Type BV, Grade
33 steel, 6 ft
span
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
OB500
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
OB500 SBS-SA (Optional) SBS-
SA SBS-SA -52.5
LWC-4
Min. 22 ga.,
Type BV, Grade
33 steel, 6 ft
span
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
Polyset Board-
Max
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
Polyset Board-
Max SBS-SA (Optional) SBS-
SA SBS-SA -52.5
LWC-5
Min. 22 ga.,
Type BV, Grade
33 steel, 6 ft
span
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
Polyset CR-20
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
Polyset CR-20 SBS-SA (Optional) SBS-
SA SBS-SA -52.5
HYBRID SYSTEMS:
LWC-6
Min. 22 ga.,
Type BV, Grade
33 steel, 6 ft
span
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
FlintFast QS,
FlintFast LV,
OB500, Polyset
Board-Max,
Polyset CR-20
(Optional) Min. 0.25-
inch SECUROCK
Gypsum-Fiber Roof
Board
FlintFast QS,
FlintFast LV,
OB500, Polyset
Board-Max,
Polyset CR-20
SBS-SA-H
(Optional) SBS-
AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-52.5
CONVENTIONAL SYSTEMS:
LWC-7
Min. 22 ga.,
Type BV, Grade
33 steel, 6 ft
span
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
FlintFast QS
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast QS
BP-AA or
SBS-AA, SBS-
TA or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-52.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 42 of 75
TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
LWIC
(Note 14)
Base Insulation Layer Coverboard Roof Cover (Note 15) MDP
(psf) Type Attach Type Attach Base Ply Ply Cap Ply
LWC-8
Min. 22 ga.,
Type BV, Grade
33 steel, 6 ft
span
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
FlintFast LV
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
FlintFast LV
BP-AA or
SBS-AA, SBS-
TA or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-52.5
LWC-9
Min. 22 ga.,
Type BV, Grade
33 steel, 6 ft
span
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
OB500
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
OB500
BP-AA or
SBS-AA, SBS-
TA or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-52.5
LWC-10
Min. 22 ga.,
Type BV, Grade
33 steel, 6 ft
span
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
Polyset Board-
Max
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
Polyset Board-
Max
BP-AA or
SBS-AA, SBS-
TA or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-52.5
LWC-11
Min. 22 ga.,
Type BV, Grade
33 steel, 6 ft
span
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
Polyset CR-20
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
Polyset CR-20
BP-AA or
SBS-AA, SBS-
TA or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-52.5
ELASTIZELL (FL4994):
COLD APPLIED SYSTEMS:
LWC-12
Min. 22 ga.,
Type BV, Grade
33 steel, 5 ft
span
Min. 350 psi, min 2-inch
Range II Elastizell with
Zell-Crete Fibers.
Min. 1.5-inch H-Shield CG,
FlintBoard ISO Cold H
OB500, 6-inch
o.c.
(Optional) Additional
layers of base
insulation
OB500, 6-inch
o.c.
BP-CA3 or
SBS-CA3
(Optional) BP-
CA3 or SBS-CA3 SBS-CA3 -60.0
LWC-13
Min. 22 ga.,
Type BV, Grade
33 steel, 5 ft
span
Min. 350 psi, min 2-inch
Range II Elastizell with Zell-
Crete Fibers. When
walkable, attach LWC with
FlintFast #14 and FlintFast
3” Round Plates at 1 per 8
ft2 through to the structural
deck.
Min. 1.5-inch H-Shield CG,
FlintBoard ISO Cold H
OB500, 6-inch
o.c.
(Optional) Additional
layers of base
insulation
OB500, 6-inch
o.c.
BP-CA3 or
SBS-CA3
(Optional) BP-
CA3 or SBS-CA3 SBS-CA3 -67.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 43 of 75
TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
LWIC
(Note 14)
Base Insulation Layer Coverboard Roof Cover (Note 15)
MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Primer Base Ply Ply Cap Ply
CELCORE (FL2037):
SELF-ADHERING SYSTEMS:
LWC-14 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, ACFoam
III, FlintBoard ISO Cold, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO ColdH
FlintFast QS Min. 0.25-inch DensDeck FlintFast QS
FlintPrime
QD,
Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -90.0
LWC-15 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, ACFoam
III, FlintBoard ISO Cold, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO ColdH
FlintFast QS
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
FlintFast QS None SBS-SA (Optional)
SBS-SA SBS-SA -90.0
LWC-16 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound and surfaced
with Celcore Sanded
Bonding Surface (SBS)
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, ACFoam
III, FlintBoard ISO Cold, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO ColdH
FlintFast QS
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
FlintFast QS None SBS-SA (Optional)
SBS-SA SBS-SA -172.5
LWC-17 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound and surfaced
with Celcore Sanded
Bonding Surface (SBS)
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, ACFoam
III, FlintBoard ISO Cold, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO ColdH
FlintFast QS Min. 0.25-inch DensDeck FlintFast QS
FlintPrime
QD,
Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -192.5
LWC-18 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound and surfaced
with Celcore Sanded
Bonding Surface (SBS)
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, ACFoam
III, FlintBoard ISO Cold, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO ColdH
FlintFast QS
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
FlintFast QS
ASTM D41
or Karnak
#108
Asphalt
Primer
SBS-SA (Optional)
SBS-SA SBS-SA -217.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 44 of 75
TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
LWIC
(Note 14)
Base Insulation Layer Coverboard Roof Cover (Note 15)
MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Primer Base Ply Ply Cap Ply
LWC-19 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, ACFoam
III, FlintBoard ISO Cold, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO ColdH
FlintFast LV
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
FlintFast LV None SBS-SA (Optional)
SBS-SA SBS-SA -172.5
LWC-20 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound and surfaced
with Celcore Sanded
Bonding Surface (SBS)
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, ACFoam
III, FlintBoard ISO Cold, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO ColdH
FlintFast LV
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
FlintFast LV None SBS-SA (Optional)
SBS-SA SBS-SA -172.5
LWC-21 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, ACFoam
III, FlintBoard ISO Cold, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO ColdH
FlintFast LV Min. 0.25-inch DensDeck FlintFast LV
FlintPrime
QD,
Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -192.5
LWC-22 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound and surfaced
with Celcore Sanded
Bonding Surface (SBS)
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, ACFoam
III, FlintBoard ISO Cold, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO ColdH
FlintFast LV Min. 0.25-inch DensDeck FlintFast LV
FlintPrime
QD,
Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -192.5
LWC-23 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, ACFoam
III, FlintBoard ISO Cold, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO ColdH
FlintFast LV
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
FlintFast LV
ASTM D41
or Karnak
#108
Asphalt
Primer
SBS-SA (Optional)
SBS-SA SBS-SA -240.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 45 of 75
TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
LWIC
(Note 14)
Base Insulation Layer Coverboard Roof Cover (Note 15)
MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Primer Base Ply Ply Cap Ply
LWC-24 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound and surfaced
with Celcore Sanded
Bonding Surface (SBS)
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, ACFoam
III, FlintBoard ISO Cold, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO ColdH
FlintFast LV
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
FlintFast LV
ASTM D41
or Karnak
#108
Asphalt
Primer
SBS-SA (Optional)
SBS-SA SBS-SA -232.5
LWC-25 Structural
concrete
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
OB500
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
OB500 None SBS-SA (Optional)
SBS-SA SBS-SA -172.5
LWC-26 Structural
concrete
Min. 200 psi, min. 2-inch
Celcore Cellular Concrete
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H or min. 1.5-
inch Multi-Max FA3, Ultra-Max
Polyset CR-20
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
Polyset CR-20 None SBS-SA (Optional)
SBS-SA SBS-SA -172.5
LWC-27 Structural
concrete
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
Polyset CR-20
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
Polyset CR-20 None SBS-SA (Optional)
SBS-SA SBS-SA -172.5
LWC-28 Structural
concrete
Min. 200 psi, min. 2-inch
Celcore Cellular Concrete
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H or min. 1.5-
inch Multi-Max FA3, Ultra-Max
Polyset CR-20 Min. 0.25-inch DensDeck Polyset CR-20
FlintPrime
QD,
Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -180.0
HYBRID SYSTEMS:
LWC-29 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
FlintFast QS
(Optional) Min. 0.25-inch
DensDeck Prime or
SECUROCK Gypsum-Fiber
Roof Board
FlintFast QS None SBS-SA-H
(Optional)
SBS-AA, SBS-
TA, APP-TA
SBS-AA,
SBS-TA,
APP-TA
-90.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 46 of 75
TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
LWIC
(Note 14)
Base Insulation Layer Coverboard Roof Cover (Note 15)
MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Primer Base Ply Ply Cap Ply
LWC-30 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound and surfaced
with Celcore Sanded
Bonding Surface (SBS)
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
FlintFast QS
(Optional) Min. 0.25-inch
DensDeck Prime or
SECUROCK Gypsum-Fiber
Roof Board
FlintFast QS None SBS-SA-H
(Optional)
SBS-AA, SBS-
TA, APP-TA
SBS-AA,
SBS-TA,
APP-TA
-217.5
LWC-31 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound and surfaced
with Celcore Sanded
Bonding Surface (SBS)
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
FlintFast LV
(Optional) Min. 0.25-inch
DensDeck Prime or
SECUROCK Gypsum-Fiber
Roof Board
FlintFast LV None SBS-SA-H
(Optional)
SBS-AA, SBS-
TA, APP-TA
SBS-AA,
SBS-TA,
APP-TA
-232.5
LWC-32 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, H-
Shield, FlintBoard ISOH
FlintFast LV
(Optional) Min. 0.25-inch
DensDeck Prime or
SECUROCK Gypsum-Fiber
Roof Board
FlintFast LV None SBS-SA-H
(Optional)
SBS-AA, SBS-
TA, APP-TA
SBS-AA,
SBS-TA,
APP-TA
-240.0
LWC-33 Structural
concrete
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
OB500
(Optional) Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
OB500 None SBS-SA-H
(Optional)
SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-215.0
LWC-34 Structural
concrete
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
Polyset
Board-Max or
Polyset CR-20
(Optional) Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
Polyset Board-
Max or
Polyset CR-20
None SBS-SA-H
(Optional)
SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-215.0
CONVENTIONAL SYSTEMS:
LWC-35 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, ACFoam
III, FlintBoard ISO Cold, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO ColdH
FlintFast QS
Min. 0.25-inch DensDeck
Prime or SECUROCK
Gypsum-Fiber Roof
Board
FlintFast QS None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-90.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 47 of 75
TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
LWIC
(Note 14)
Base Insulation Layer Coverboard Roof Cover (Note 15)
MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Primer Base Ply Ply Cap Ply
LWC-36 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound and surfaced
with Celcore Sanded
Bonding Surface (SBS)
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, ACFoam
III, FlintBoard ISO Cold, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO ColdH
FlintFast QS
Min. 0.25-inch DensDeck
Prime or SECUROCK
Gypsum-Fiber Roof
Board
FlintFast QS None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-217.5
LWC-37 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, ACFoam
III, FlintBoard ISO Cold, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO ColdH
FlintFast LV
Min. 0.25-inch DensDeck
Prime or SECUROCK
Gypsum-Fiber Roof
Board
FlintFast LV None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-240.0
LWC-38 Structural
concrete
Min. 300 psi, min. 2-inch
thick Celcore MF Cellular
Concrete with Celcore HS
Rheology Modifying
Admixture; treated with
Celcore PVA Curing
Compound and surfaced
with Celcore Sanded
Bonding Surface (SBS)
One or more layer(s), min. 1.5-inch
ACFoam II, FlintBoard ISO, ACFoam
III, FlintBoard ISO Cold, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO ColdH
FlintFast LV
Min. 0.25-inch DensDeck
Prime or SECUROCK
Gypsum-Fiber Roof
Board
FlintFast LV None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-232.5
LWC-39 Structural
concrete
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
OB500
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
OB500 None
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-215.0
LWC-40 Structural
concrete
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
Polyset
Board-Max
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
Polyset Board-
Max None
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-215.0
LWC-41 Structural
concrete
Min. 200 psi, min. 2-inch
Celcore Cellular Concrete
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H or min. 1.5-
inch Multi-Max FA3, Ultra-Max
Polyset CR-20 Min. 0.5-inch Structodek
High Density Fiberboard Polyset CR-20 None BP-AA or
SBS-AA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-180.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 48 of 75
TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
LWIC
(Note 14)
Base Insulation Layer Coverboard Roof Cover (Note 15)
MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Primer Base Ply Ply Cap Ply
LWC-42 Structural
concrete
Min. 200 psi, min. 2-inch
Celcore Cellular Concrete
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H or min. 1.5-
inch Multi-Max FA3, Ultra-Max
Polyset CR-20
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board or DensDeck
or DensDeck Prime
Polyset CR-20 None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-180.0
LWC-43 Structural
concrete
Min. 300 psi Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
One or more layer(s), min. 1.5-inch
thick ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, H-
Shield, FlintBoard ISOH, H-Shield
CG, FlintBoard ISO Cold H
Polyset CR-20
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
Polyset CR-20 None
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-215.0
ELASTIZELL (FL4994):
SELF-ADHERING SYSTEMS:
LWC-44 Structural
concrete
Min. 200 psi, min. 2-
inch Elastizell
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500
FlintPrime
QD,
Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -150.0
LWC-45 Structural
concrete
Min. 200 psi, min. 2-
inch Elastizell
Min. 1.5-inch ACFoam II, FlintBoard
ISO, ENRGY 3, H-Shield, FlintBoard
ISOH
OB500
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
OB500 None SBS-SA (Optional)
SBS-SA SBS-SA -172.5
LWC-46 Structural
concrete
Min. 200 psi, min. 2-
inch Elastizell
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H or min. 1.5-
inch Multi-Max FA3, Ultra-Max
Polyset CR-20
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
Polyset CR-20 None SBS-SA (Optional)
SBS-SA SBS-SA -172.5
LWC-47 Structural
concrete
Min. 200 psi, min. 2-
inch Elastizell
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H or min. 1.5-
inch Multi-Max FA3, Ultra-Max
Polyset CR-20 Min. 0.25-inch DensDeck Polyset CR-20
FlintPrime
QD,
Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -180.0
CONVENTIONAL SYSTEMS:
LWC-48 Structural
concrete
Min. 200 psi, min. 2-
inch Elastizell
Min. 1.5-inch ACFoam II or
FlintBoard ISO. OB500 Min. 0.25-inch DensDeck
or DensDeck Prime OB500 None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-150.0
LWC-49 Structural
concrete
Min. 200 psi, min. 2-
inch Elastizell
Min. 1.5-inch ACFoam II or
FlintBoard ISO. OB500
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
OB500 None SBS-TA (Optional)
SBS-TA SBS-TA -180.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 49 of 75
TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
LWIC
(Note 14)
Base Insulation Layer Coverboard Roof Cover (Note 15)
MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Primer Base Ply Ply Cap Ply
LWC-50 Structural
concrete
Min. 200 psi, min. 2-
inch Elastizell
Min. 2-inch ACFoam II, FlintBoard
ISO, ENRGY 3, H-Shield, FlintBoard
ISOH
OB500
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
OB500 None
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-225.0
LWC-51 Structural
concrete
Min. 200 psi, min. 2-
inch Elastizell
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H or min. 1.5-
inch Multi-Max FA3, Ultra-Max
Polyset CR-20 Min. 0.5-inch Structodek
High Density Fiberboard Polyset CR-20 None BP-AA or
SBS-AA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-180.0
LWC-52 Structural
concrete
Min. 200 psi, min. 2-
inch Elastizell
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H or min. 1.5-
inch Multi-Max FA3, Ultra-Max
Polyset CR-20
Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board or DensDeck
or DensDeck Prime
Polyset CR-20 None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-180.0
COLD APPLIED SYSTEMS:
LWC-53 Structural
concrete
Min. 350 psi, min 2-
inch Elastizell with
Zell-Crete Fibers.
Min. 1.5-inch H-Shield CG OB500, 6-inch
o.c.
(Optional) Additional
layers of base insulation
OB500, 6-inch
o.c. None BP-CA3 or
SBS-CA3
(Optional)
BP-CA3 or
SBS-CA3
SBS-CA3 -60.0
LWC-54 Structural
concrete
Min. 350 psi, min 2-inch
Range II Elastizell with
Zell-Crete Fibers. When
walkable, attach LWC
with FlintFast #14 and
FlintFast 3” Round Plates
at 1 per 8 ft2 through to
the structural deck.
Min. 1.5-inch H-Shield CG OB500, 6-inch
o.c.
(Optional) Additional
layers of base insulation
OB500, 6-inch
o.c. None BP-CA3 or
SBS-CA3
(Optional)
BP-CA3 or
SBS-CA3
SBS-CA3 -67.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 50 of 75
TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: LWC TO DECK, BONDED VAPOR BARRIER, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
LWIC
(Note 14) Vapor Barrier
Base Insulation Layer Coverboard
Primer
Roof Cover (Note 15)
MDP
(psf) Type
Attach
(Notes
6&7)
Type
Attach
(Notes
6&7)
Base Ply Ply Cap Ply
PRE-EXISTENT CELLULAR LWC:
SELF-ADHERING SYSTEMS:
LWC-55
Min. 22
ga., Type
BV, Grade
40 steel
Min. 400 psi, Min. 2-
inch thick, existing (>
28 days old) cellular
lightweight concrete,
Repair LWC spalls with
Celcore SBS (Sanded
Bonding Surface)
Flintlastic Ultra Poly SMS Base Sheet
applied in HB Fuller “Millennium
Hurricane Force Membrane Adhesive
HS”, ribbons max. 6-inch o.c. 3-inch
wide side laps and 6-inch wide end laps
are hot-air-welded, torch-welded or
sealed with HB Fuller “Millennium
Hurricane Force Lap and Flashing
Adhesive”
One or more layers,
min. 2-in. ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
H ISO
FlintFast
QS or
FlintFast
LV
(Optional) 0.5-
in. DensDeck
Prime or
SECUROCK
Gypsum-Fiber
Roof Board
FlintFast
QS or
FlintFast
LV
FlintPrime
QD,
Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -67.5
HYBRID SYSTEMS:
LWC-56
Min. 22
ga., Type
BV, Grade
40 steel
Min. 400 psi, Min. 2-
inch thick, existing (>
28 days old) cellular
lightweight concrete,
Repair LWC spalls with
Celcore SBS (Sanded
Bonding Surface)
Flintlastic Ultra Poly SMS Base Sheet
applied in HB Fuller “Millennium
Hurricane Force Membrane Adhesive
HS”, ribbons max. 6-inch o.c. 3-inch
wide side laps and 6-inch wide end laps
are hot-air-welded, torch-welded or
sealed with HB Fuller “Millennium
Hurricane Force Lap and Flashing
Adhesive”
One or more layers,
min. 2-in. ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
H ISO
FlintFast
QS or
FlintFast
LV
0.5-in.
DensDeck
Prime or
SECUROCK
Gypsum-Fiber
Roof Board
FlintFast
QS or
FlintFast
LV
(Optional)
ASTM D41
or Karnak
#108
Asphalt
Primer
SBS-SA-H
(Optional)
SBS-TA or
APP-TA
SBS-TA
or APP-
TA
-67.5
CONVENTIONAL SYSTEMS:
LWC-57
Min. 22
ga., Type
BV, Grade
40 steel
Min. 400 psi, Min. 2-
inch thick, existing (>
28 days old) cellular
lightweight concrete,
Repair LWC spalls with
Celcore SBS (Sanded
Bonding Surface)
Flintlastic Ultra Poly SMS Base Sheet
applied in HB Fuller “Millennium
Hurricane Force Membrane Adhesive
HS”, ribbons max. 6-inch o.c. 3-inch
wide side laps and 6-inch wide end laps
are hot-air-welded, torch-welded or
sealed with HB Fuller “Millennium
Hurricane Force Lap and Flashing
Adhesive”
One or more layers,
min. 2-in. ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
H ISO
FlintFast
QS or
FlintFast
LV
0.5-in.
DensDeck
Prime or
SECUROCK
Gypsum-Fiber
Roof Board
FlintFast
QS or
FlintFast
LV
(Optional)
ASTM D41
or Karnak
#108
Asphalt
Primer
SBS-TA or
APP-TA
(Optional)
SBS-TA or
APP-TA
SBS-TA
or APP-
TA
-67.5
ELASTIZELL (FL4994):
SELF-ADHERING SYSTEMS:
LWC-58 Structural
Concrete
Min. 420 psi, min.
2-inch Elastizell
All Weather/Empire Base Sheet applied
in HB Fuller “Millennium Hurricane
Force Membrane Adhesive HS”, ribbons
max. 6-inch o.c., 3-inch wide side laps
and 6-inch wide end laps are sealed
with HB Fuller “Millennium Hurricane
Force Lap and Flashing Adhesive”
One or more layers,
min. 2-in. ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
H ISO
FlintFast
QS or
FlintFast
LV
(Optional) 0.5-
in. DensDeck
Prime or
SECUROCK
Gypsum-Fiber
Roof Board
FlintFast
QS or
FlintFast
LV
FlintPrime
QD,
Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -67.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 51 of 75
TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: LWC TO DECK, BONDED VAPOR BARRIER, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
LWIC
(Note 14) Vapor Barrier
Base Insulation Layer Coverboard
Primer
Roof Cover (Note 15)
MDP
(psf) Type
Attach
(Notes
6&7)
Type
Attach
(Notes
6&7)
Base Ply Ply Cap Ply
LWC-59 Structural
Concrete
Min. 420 psi, min.
2-inch Elastizell
Flintlastic Ultra Poly SMS Base Sheet
applied in HB Fuller “Millennium
Hurricane Force Membrane Adhesive
HS”, ribbons max. 6-inch o.c., 3-inch
wide side laps and 6-inch wide end laps
are hot-air-welded, torch-welded or
sealed with HB Fuller “Millennium
Hurricane Force Lap and Flashing
Adhesive”
One or more layers,
min. 2-in. ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
H ISO
FlintFast
QS or
FlintFast
LV
(Optional) 0.5-
in. DensDeck
Prime or
SECUROCK
Gypsum-Fiber
Roof Board
FlintFast
QS or
FlintFast
LV
FlintPrime
QD,
Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -67.5
HYBRID SYSTEMS:
LWC-60 Structural
Concrete
Min. 420 psi, min.
2-inch Elastizell
All Weather/Empire Base Sheet applied
in HB Fuller “Millennium Hurricane
Force Membrane Adhesive HS”, ribbons
max. 6-inch o.c., 3-inch wide side laps
and 6-inch wide end laps are sealed
with HB Fuller “Millennium Hurricane
Force Lap and Flashing Adhesive”
One or more layers,
min. 2-in. ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
H ISO
FlintFast
QS or
FlintFast
LV
0.5-in.
DensDeck
Prime or
SECUROCK
Gypsum-Fiber
Roof Board
FlintFast
QS or
FlintFast
LV
(Optional)
ASTM D41
or Karnak
#108
Asphalt
Primer
SBS-SA-H
(Optional)
SBS-TA or
APP-TA
SBS-TA
or APP-
TA
-67.5
LWC-61 Structural
Concrete
Min. 420 psi, min.
2-inch Elastizell
Flintlastic Ultra Poly SMS Base Sheet
applied in HB Fuller “Millennium
Hurricane Force Membrane Adhesive
HS”, ribbons max. 6-inch o.c., 3-inch
wide side laps and 6-inch wide end laps
are hot-air-welded, torch-welded or
sealed with HB Fuller “Millennium
Hurricane Force Lap and Flashing
Adhesive”
One or more layers,
min. 2-in. ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
H ISO
FlintFast
QS or
FlintFast
LV
0.5-in.
DensDeck
Prime or
SECUROCK
Gypsum-Fiber
Roof Board
FlintFast
QS or
FlintFast
LV
(Optional)
ASTM D41
or Karnak
#108
Asphalt
Primer
SBS-SA-H
(Optional)
SBS-TA or
APP-TA
SBS-TA
or APP-
TA
-67.5
CONVENTIONAL SYSTEMS:
LWC-62 Structural
Concrete
Min. 420 psi, min.
2-inch Elastizell
All Weather/Empire Base Sheet applied
in HB Fuller “Millennium Hurricane
Force Membrane Adhesive HS”, ribbons
max. 6-inch o.c., 3-inch wide side laps
and 6-inch wide end laps are sealed
with HB Fuller “Millennium Hurricane
Force Lap and Flashing Adhesive”
One or more layers,
min. 2-in. ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
H ISO
FlintFast
QS or
FlintFast
LV
0.5-in.
DensDeck
Prime or
SECUROCK
Gypsum-Fiber
Roof Board
FlintFast
QS or
FlintFast
LV
(Optional)
ASTM D41
or Karnak
#108
Asphalt
Primer
SBS-TA or
APP-TA
(Optional)
SBS-TA or
APP-TA
SBS-TA
or APP-
TA
-67.5
LWC-63 Structural
Concrete
Min. 420 psi, min.
2-inch Elastizell
Flintlastic Ultra Poly SMS Base Sheet
applied in HB Fuller “Millennium
Hurricane Force Membrane Adhesive
HS”, ribbons max. 6-inch o.c., 3-inch
wide side laps and 6-inch wide end laps
are hot-air-welded, torch-welded or
sealed with HB Fuller “Millennium
Hurricane Force Lap and Flashing
Adhesive”
One or more layers,
min. 2-in. ACFoam
II, FlintBoard ISO, H-
Shield or FlintBoard
H ISO
FlintFast
QS or
FlintFast
LV
0.5-in.
DensDeck
Prime or
SECUROCK
Gypsum-Fiber
Roof Board
FlintFast
QS or
FlintFast
LV
(Optional)
ASTM D41
or Karnak
#108
Asphalt
Primer
SBS-TA or
APP-TA
(Optional)
SBS-TA or
APP-TA
SBS-TA
or APP-
TA
-67.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 52 of 75
TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15) MDP
(psf) Deck
Treatment Type Surface
Treatment Type Fasteners Attach Base Top Attach Base Ply Ply Cap Ply
PRE-EXISTENT CELLULAR LWC:
CONVENTIONAL SYSTEMS:
CELCORE (FL2037):
SELF-ADHERING SYSTEMS:
LWC-64
Min. 22 ga.,
type BV,
Grade 40
steel, 6 ft
span
Celcore S-1
Deck
Preparation
Min. 470 psi,
min. 2-inch
Celcore MF
Cellular
Concrete with
Celcore HS
Rheology
Modifying
Admixture
Celcore PVA
Curing
Compound
All
Weather/Empire
Base Sheet,
Glasbase Base
Sheet or Flintlastic
Base 20
Trufast FM-
90 Base
Sheet
Fasteners
7-inch o.c. at the
min. 4-inch side
laps and 7-inch
o.c. at two,
equally spaced,
staggered center
rows
Min. 1.5"
FlintBoard
ISO or
FlintBoard
ISO-T
(Optional) Min. 0.25-
inch DensDeck Prime
or SECUROCK
Gypsum-Fiber Roof
Board. Top surface
shall be primed with
FlintPrime QD,
Karnak #108 or
ASTM D41 primer.
hot
asphalt SBA-SA (Optional)
SBS-SA SBS-SA -60.0
HYBRID SYSTEMS:
LWC-65
Min. 22 ga.,
type BV,
Grade 40
steel, 6 ft
span
Celcore S-1
Deck
Preparation
Min. 470 psi,
min. 2-inch
Celcore MF
Cellular
Concrete with
Celcore HS
Rheology
Modifying
Admixture
Celcore PVA
Curing
Compound
All
Weather/Empire
Base Sheet,
Glasbase Base
Sheet or Flintlastic
Base 20
Trufast FM-
90 Base
Sheet
Fasteners
7-inch o.c. at the
min. 4-inch side
laps and 7-inch
o.c. at two,
equally spaced,
staggered center
rows
Min. 1.5"
FlintBoard
ISO or
FlintBoard
ISO-T
(Optional) Min.
0.125-inch STURDY-
DEK Asphaltic Cover
Board or min. 0.25-
inch DensDeck Prime
or SECUROCK
Gypsum-Fiber Roof
Board. Top surface
may be optionally
primed with ASTM
D41 or Karnak #108
Asphalt Primer.
hot
asphalt SBS-SA-H
(Optional)
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-60.0
CONVENTIONAL SYSTEMS:
LWC-66
Min. 22 ga.,
type BV,
Grade 40
steel, 6 ft
span
Celcore S-1
Deck
Preparation
Min. 470 psi,
min. 2-inch
Celcore MF
Cellular
Concrete with
Celcore HS
Rheology
Modifying
Admixture
Celcore PVA
Curing
Compound
All
Weather/Empire
Base Sheet,
Glasbase Base
Sheet or Flintlastic
Base 20
Trufast FM-
90 Base
Sheet
Fasteners
7-inch o.c. at the
min. 4-inch side
laps and 7-inch
o.c. at two,
equally spaced,
staggered center
rows
Min. 1.5"
FlintBoard
ISO or
FlintBoard
ISO-T
Min. 0.125-inch
STURDY-DEK
Asphaltic Cover
Board, min. 0.25-inch
DensDeck Prime or
SECUROCK Gypsum-
Fiber Roof Board,
min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
min. 0.75-inch Fesco
Board
(homogeneous)
hot
asphalt
BP-AA or
SBS-AA
(Optional)
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 53 of 75
TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15) MDP
(psf) Deck
Treatment Type Surface
Treatment Type Fasteners Attach Base Top Attach Base Ply Ply Cap Ply
LWC-67
Min. 22 ga.,
type BV,
Grade 40
steel, 6 ft
span
Celcore S-1
Deck
Preparation
Min. 470 psi,
min. 2-inch
Celcore MF
Cellular
Concrete with
Celcore HS
Rheology
Modifying
Admixture
Celcore PVA
Curing
Compound
All
Weather/Empire
Base Sheet,
Glasbase Base
Sheet or Flintlastic
Base 20
Trufast FM-
90 Base
Sheet
Fasteners
7-inch o.c. at the
min. 4-inch side
laps and 7-inch
o.c. at two,
equally spaced,
staggered center
rows
Min. 1.5"
FlintBoard
ISO or
FlintBoard
ISO-T
Min. 0.125-inch
STURDY-DEK
Asphaltic Cover
Board or min. 0.25-
inch DensDeck Prime
or SECUROCK
Gypsum-Fiber Roof
Board. Top surface
may be optionally
primed with ASTM
D41 or Karnak #108
Asphalt Primer.
hot
asphalt
SBS-TA or
APP-TA
(Optional)
SBS-TA or
APP-TA
SBS-TA
or APP-
TA
-60.0
ELASTIZELL (FL4994):
SELF-ADHERING SYSTEMS:
LWC-68
Min. 22 ga.,
type BV,
Grade 40
steel, 6 ft
span
None
Min. 490 psi,
min. 2-inch
Elastizell with
Zell-Crete
Fibers
None
All
Weather/Empire
Base Sheet,
Glasbase Base
Sheet or Flintlastic
Base 20
Trufast FM-
90 Base
Sheet
Fasteners
7-inch o.c. at the
min. 4-inch side
laps and 7-inch
o.c. at two,
equally spaced,
staggered center
rows
Min. 1.5"
FlintBoard
ISO or
FlintBoard
ISO-T
(Optional) Min. 0.25-
inch DensDeck Prime
or SECUROCK
Gypsum-Fiber Roof
Board. Top surface
shall be primed with
FlintPrime QD,
Karnak #108 or
ASTM D41 primer.
hot
asphalt SBA-SA (Optional)
SBS-SA SBS-SA -67.5
HYBRID SYSTEMS:
LWC-69
Min. 22 ga.,
type BV,
Grade 40
steel, 6 ft
span
None
Min. 490 psi,
min. 2-inch
Elastizell with
Zell-Crete
Fibers
None
All
Weather/Empire
Base Sheet,
Glasbase Base
Sheet or Flintlastic
Base 20
Trufast FM-
90 Base
Sheet
Fasteners
7-inch o.c. at the
min. 4-inch side
laps and 7-inch
o.c. at two,
equally spaced,
staggered center
rows
Min. 1.5"
FlintBoard
ISO or
FlintBoard
ISO-T
(Optional) Min.
0.125-inch STURDY-
DEK Asphaltic Cover
Board or min. 0.25-
inch DensDeck Prime
or SECUROCK
Gypsum-Fiber Roof
Board. Top surface
may be optionally
primed with ASTM
D41 or Karnak #108
Asphalt Primer.
hot
asphalt SBS-SA-H
(Optional)
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-67.5
CONVENTIONAL SYSTEMS:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 54 of 75
TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15) MDP
(psf) Deck
Treatment Type Surface
Treatment Type Fasteners Attach Base Top Attach Base Ply Ply Cap Ply
LWC-70
Min. 22 ga.,
type BV,
Grade 40
steel, 6 ft
span
None
Min. 490 psi,
min. 2-inch
Elastizell with
Zell-Crete
Fibers
None
All
Weather/Empire
Base Sheet,
Glasbase Base
Sheet or Flintlastic
Base 20
Trufast FM-
90 Base
Sheet
Fasteners
7-inch o.c. at the
min. 4-inch side
laps and 7-inch
o.c. at two,
equally spaced,
staggered center
rows
Min. 1.5"
FlintBoard
ISO or
FlintBoard
ISO-T
Min. 0.125-inch
STURDY-DEK
Asphaltic Cover
Board, min. 0.25-inch
DensDeck Prime or
SECUROCK Gypsum-
Fiber Roof Board,
min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
min. 0.75-inch Fesco
Board
(homogeneous)
hot
asphalt
BP-AA or
SBS-AA
(Optional)
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-67.5
LWC-71
Min. 22 ga.,
type BV,
Grade 40
steel, 6 ft
span
None
Min. 490 psi,
min. 2-inch
Elastizell with
Zell-Crete
Fibers
None
All
Weather/Empire
Base Sheet,
Glasbase Base
Sheet or Flintlastic
Base 20
Trufast FM-
90 Base
Sheet
Fasteners
7-inch o.c. at the
min. 4-inch side
laps and 7-inch
o.c. at two,
equally spaced,
staggered center
rows
Min. 1.5"
FlintBoard
ISO or
FlintBoard
ISO-T
Min. 0.125-inch
STURDY-DEK
Asphaltic Cover
Board or min. 0.25-
inch DensDeck Prime
or SECUROCK
Gypsum-Fiber Roof
Board. Top surface
may be optionally
primed with ASTM
D41 or Karnak #108
Asphalt Primer.
hot
asphalt
SBS-TA or
APP-TA
(Optional)
SBS-TA or
APP-TA
SBS-TA
or APP-
TA
-67.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 55 of 75
TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP
(psf) Deck
Treatment LWC Surface
Treatment Type Fasteners Attach Base Ply Cap Ply
PRE-EXISTENT CELLULAR LWIC:
SELF-ADHERING SYSTEMS:
LWC-72
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
None
Min. 300 psi, min. 2-
inch pre-existent
cellular lightweight
insulating concrete.
None Flintlastic SA NailBase
Trufast Twin Loc-
Nail Assembled
Fastener (min.
1.8”)
7-inch o.c. at the min. 2-inch lap and 7-
inch o.c. in two (2), equally spaced,
staggered center rows, Prime stress
plates with ASTM D41 primer
SBS-SA SBS-SA -60.0
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 73 lbf when tested per ANSI/SPRI FX-1 or TAS 105
LWC-73
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
None
Min. 300 psi, min. 2-
inch pre-existent
cellular lightweight
insulating concrete.
None Flintlastic SA NailBase
Trufast Twin Loc-
Nail Assembled
Fastener (min.
1.8”)
9-inch o.c. at the min. 2-inch lap and 9-
inch o.c. in two (2), equally spaced,
staggered center rows, Prime stress
plates with ASTM D41 primer
SBS-SA SBS-SA -60.0
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 93 lbf when tested per ANSI/SPRI FX-1 or TAS 105
HYBRID SYSTEMS:
LWC-74
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
None
Min. 300 psi, min. 2-
inch pre-existent
cellular lightweight
insulating concrete.
None
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet
Trufast Twin Loc-
Nail Assembled
Fastener (min.
1.8”)
9-inch o.c. at the 4-inch lap and 9-inch
o.c. in two (2), equally spaced,
staggered center rows
SBS-SA-H
SBS-AA, SBS-
TA or APP-
TA
-60.0
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 88 lbf when tested per ANSI/SPRI FX-1 or TAS 105
LWC-75
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
None
Min. 350 psi, min. 3-
inch pre-existent
cellular lightweight
insulating concrete.
None
Flintlastic Base 20 or
Flintlastic Poly SMS
Base Sheet
Trufast FM-90
Base Sheet
Fasteners
7-inch o.c. at the 4-inch lap and 10-inch
o.c. in two (2), equally spaced,
staggered center rows
SBS-SA-H
SBS-AA, SBS-
TA or APP-
TA
-67.5
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 97 lbf when tested per ANSI/SPRI FX-1 or TAS 105
LWC-76
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
None
Min. 300 psi, min. 2-
inch pre-existent
cellular lightweight
insulating concrete.
None
Flintlastic Poly SMS
Base Sheet, Flintlastic
Ultra Poly SMS Base
Sheet
Trufast Twin Loc-
Nail Assembled
Fastener (min.
1.8”)
9-inch o.c. at the 4-inch lap and 9-inch
o.c. in two (2), equally spaced,
staggered center rows
SBS-SA-H
SBS-AA, SBS-
TA or APP-
TA
-75.0
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 110 lbf when tested per ANSI/SPRI FX-1 or TAS 105
CONVENTIONAL SYSTEMS:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 56 of 75
TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP
(psf) Deck
Treatment LWC Surface
Treatment Type Fasteners Attach Base Ply Cap Ply
LWC-77
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
None
Min. 300 psi, min. 2-
inch pre-existent
cellular lightweight
insulating concrete.
None
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet
Trufast Twin Loc-
Nail Assembled
Fastener (min.
1.8”)
9-inch o.c. at the 4-inch lap and 9-inch
o.c. in two (2), equally spaced,
staggered center rows
(Optional)
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-
TA
-60.0
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 88 lbf when tested per ANSI/SPRI FX-1 or TAS 105
LWC-78
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
None
Min. 300 psi, min. 2-
inch pre-existent
cellular lightweight
insulating concrete.
None
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet
Trufast Twin Loc-
Nail Assembled
Fastener (min.
1.8”)
7-inch o.c. at the 4-inch lap and 7-inch
o.c. in two (2), equally spaced,
staggered center rows
BP-AA or
SBS-AA
SBS-AA, SBS-
TA or APP-
TA
-67.5
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 77 lbf when tested per ANSI/SPRI FX-1 or TAS 105
LWC-79
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
None
Min. 350 psi, min. 3-
inch pre-existent
cellular lightweight
insulating concrete.
None
Flintlastic Base 20,
Flintlastic Poly SMS
Base Sheet
Trufast FM-90
Base Sheet
Fasteners
7-inch o.c. at the 4-inch lap and 10-inch
o.c. in two (2), equally spaced,
staggered center rows
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-
TA
-67.5
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 97 lbf when tested per ANSI/SPRI FX-1 or TAS 105
LWC-80
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
None
Min. 300 psi, min. 2-
inch pre-existent
cellular lightweight
insulating concrete.
None
Flintlastic Poly SMS
Base Sheet, Flintlastic
Ultra Poly SMS Base
Sheet
Trufast Twin Loc-
Nail Assembled
Fastener (min.
1.8”)
9-inch o.c. at the 4-inch lap and 9-inch
o.c. in two (2), equally spaced,
staggered center rows
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-
TA
-75.0
Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 110 lbf when tested per ANSI/SPRI FX-1 or TAS 105
CELCORE (FL2037):
SELF-ADHERING SYSTEMS:
LWC-81
Min. 22 ga., type
BV, Grade 40
steel, 6 ft span
Celcore S-1
Deck
Preparation
Min. 470 psi, min. 2-
inch Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
Celcore
PVA Curing
Compound
Flintlastic SA NailBase
Trufast FM-90
Base Sheet
Fasteners
7-inch o.c. at the min. 4-inch side laps
and 7-inch o.c. at two, equally spaced,
staggered center rows
SBS-SA SBS-SA -45.0
HYBRID SYSTEMS:
LWC-82
Min. 22 ga., type
BV, Grade 40
steel, 6 ft span
Celcore S-1
Deck
Preparation
Min. 470 psi, min. 2-
inch Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
Celcore
PVA Curing
Compound
All Weather/Empire
Base Sheet, Glasbase
Base Sheet or Flintlastic
Base 20
Trufast FM-90
Base Sheet
Fasteners
7-inch o.c. at the min. 4-inch side laps
and 7-inch o.c. at two, equally spaced,
staggered center rows
SBS-SA-H
SBS-AA, SBS-
TA or APP-
TA
-45.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 57 of 75
TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP
(psf) Deck
Treatment LWC Surface
Treatment Type Fasteners Attach Base Ply Cap Ply
CONVENTIONAL SYSTEMS:
LWC-83
Min. 22 ga., type
BV, Grade 40
steel, 6 ft span
Celcore S-1
Deck
Preparation
Min. 470 psi, min. 2-
inch Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture
Celcore
PVA Curing
Compound
All Weather/Empire
Base Sheet, Glasbase
Base Sheet or Flintlastic
Base 20
Trufast FM-90
Base Sheet
Fasteners
7-inch o.c. at the min. 4-inch side laps
and 7-inch o.c. at two, equally spaced,
staggered center rows
(Optional)
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-
TA
-45.0
LWC-84
Min. 22 ga., type
B steel at max. 5
ft spans
structural
concrete
None
Min. 300 psi, min 2-
inch Celcore MF
Cellular Concrete with
Celcore HS Rheology
Modifying Admixture.
Celcore
PVA Curing
Compound
All Weather/Empire
Base Sheet, Flintlastic
Base 20, Flintlastic Poly
SMS Base Sheet
Trufast FM-90
Base Sheet
Fasteners
9-inch o.c. at 4-inch laps and 12-inch
o.c. in two (2), equally spaced,
staggered center rows
(Optional)
BP-AA,
SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -60.0
LWC-85
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
None
Min. 300 psi, min 2-
inch Celcore Cellular
Concrete.
Celcore
PVA Curing
Compound
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet, Flintlastic Poly
SMS Base Sheet
Trufast FM-90
Base Sheet
Fasteners
7-inch o.c. at the 3-inch lap and 7-inch
o.c. in two (2), equally spaced,
staggered center rows
BP-AA or
SBS-AA
SBS-AA, SBS-
TA or APP-
TA
-75.0
CONCRECEL (FL5584 & FL10500):
CONVENTIONAL SYSTEMS:
LWC-86
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
Concrecel
Bonding
Agent
Min. 300 psi, min 2¼-
inch Concrecel
Concrete.
Concrecel
Curing
Compound
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet, Flintlastic Poly
SMS Base Sheet
OMG CR Base Ply
Fasteners (1.7)
7-inch o.c. at the 3-inch lap and 7-inch
o.c. in two (2), equally spaced,
staggered center rows
(Optional)
BP-AA or
SBS-AA
SBS-AA, SBS-
TA or APP-
TA
-52.5
ELASTIZELL (FL4994):
SELF-ADHERING SYSTEMS:
LWC-87
Min. 22 ga., type
BV, Grade 40
steel, 6 ft span
None
Min. 490 psi, min. 2-
inch Elastizell with
Zell-Crete Fibers
None Flintlastic SA NailBase
Trufast FM-90
Base Sheet
Fasteners
7-inch o.c. at the min. 4-inch side laps
and 7-inch o.c. at two, equally spaced,
staggered center rows
SBS-SA SBS-SA -45.0
HYBRID SYSTEMS:
LWC-88
Min. 26 ga. steel
at max 5 ft spans
or structural
concrete
None Min. 200 psi, min 2-
inch Elastizell. None
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet or Flintlastic Poly
SMS Base Sheet
Trufast FM-90 Base
Sheet Fasteners or
Trufast Twin Loc-Nail
Assembled Fasteners
(1.8 inch)
7½-inch o.c. at the 4-inch lap and 7½-
inch o.c. in two (2), equally spaced,
staggered center rows
SBS-SA-H
SBS-AA, SBS-
TA or APP-
TA
-30.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 58 of 75
TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP
(psf) Deck
Treatment LWC Surface
Treatment Type Fasteners Attach Base Ply Cap Ply
LWC-89
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
None Min. 200 psi, min 2-
inch Elastizell. None
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet or Flintlastic Poly
SMS Base Sheet
Trufast FM-90 Base
Sheet Fasteners or
Trufast Twin Loc-Nail
Assembled Fasteners
(1.8 inch)
7-inch o.c. at the 4-inch lap and 7-inch
o.c. in two (2), equally spaced,
staggered center rows
SBS-SA-H
SBS-AA, SBS-
TA or APP-
TA
-45.0
LWC-90
Min. 22 ga., type
BV, Grade 40
steel, 6 ft span
None
Min. 490 psi, min. 2-
inch Elastizell with
Zell-Crete Fibers
None
All Weather/Empire
Base Sheet, Glasbase
Base Sheet or Flintlastic
Base 20
Trufast FM-90
Base Sheet
Fasteners
7-inch o.c. at the min. 4-inch side laps
and 7-inch o.c. at two, equally spaced,
staggered center rows
SBS-SA-H
SBS-AA, SBS-
TA or APP-
TA
-45.0
CONVENTIONAL SYSTEMS:
LWC-91
Min. 26 ga. steel
at max 5 ft spans
or structural
concrete
None Min. 200 psi, min 2-
inch Elastizell. None
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet, Flintlastic Poly
SMS Base Sheet
Trufast FM-90 Base
Sheet Fasteners or
Trufast Twin Loc-Nail
Assembled Fasteners
(1.8 inch)
7½-inch o.c. at the 4-inch lap and 7½-
inch o.c. in two (2), equally spaced,
staggered center rows
(Optional)
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-
TA
-30.0
LWC-92
Min. 26 ga. steel
at max 5 ft spans
or structural
concrete
None Min. 200 psi, min 2-
inch Elastizell. None Flintlastic APP Base T
Trufast FM-90
Base Sheet
Fasteners
7½-inch o.c. at the 4-inch lap and 7½-
inch o.c. in two (2), equally spaced,
staggered center rows
(Optional)
APP-TA APP-TA -30.0
LWC-93
Min. 22 ga., type
BV, Grade 40
steel, 6 ft span
None
Min. 490 psi, min. 2-
inch Elastizell with
Zell-Crete Fibers
None
All Weather/Empire
Base Sheet, Glasbase
Base Sheet or Flintlastic
Base 20
Trufast FM-90
Base Sheet
Fasteners
7-inch o.c. at the min. 4-inch side laps
and 7-inch o.c. at two, equally spaced,
staggered center rows
(Optional)
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-
TA
-45.0
LWC-94
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
None Min. 200 psi, min 2-
inch Elastizell. None
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet, Flintlastic Poly
SMS Base Sheet
Trufast FM-90 Base
Sheet Fasteners or
Trufast Twin Loc-Nail
Assembled Fasteners
(1.8 inch)
7-inch o.c. at the 4-inch lap and 7-inch
o.c. in two (2), equally spaced,
staggered center rows
(Optional)
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-
TA
-45.0
LWC-95
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
None Min. 200 psi, min 2-
inch Elastizell. None Flintlastic APP Base T
Trufast FM-90
Base Sheet
Fasteners
7-inch o.c. at the 4-inch lap and 7-inch
o.c. in two (2), equally spaced,
staggered center rows
(Optional)
APP-TA APP-TA -45.0
COLD APPLIED SYSTEMS:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 59 of 75
TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP
(psf) Deck
Treatment LWC Surface
Treatment Type Fasteners Attach Base Ply Cap Ply
LWC-96
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
None
Min. 350 psi, min 2-
inch Range II Elastizell
with Zell-Crete Fibers.
None
Flintlastic Base 20,
Flintlastic Poly SMS
Base Sheet
Trufast FM-90
Base Sheet
Fasteners
7-inch o.c. at the 4-inch lap and 7-inch
o.c. in two (2), equally spaced,
staggered center rows
(Optional)
BP-CA2 or
SBS-CA2
SBS-CA2 -45.0
LWC-97
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span
None
Min. 350 psi, min 2-
inch Range II Elastizell
with Zell-Crete Fibers.
None
Glasbase Base Sheet,
Flintlastic Poly SMS
Base Sheet
Trufast FM-90
Base Sheet
Fasteners
7-inch o.c. at the 4-inch lap and 7-inch
o.c. in two (2), equally spaced,
staggered center rows
(Optional)
BP-CA3 or
SBS-CA3
SBS-CA3 -52.5
LWC-98 Structural
concrete None
Min. 350 psi, min 2-
inch Range II Elastizell
with Zell-Crete Fibers.
None
Glasbase Base Sheet,
Flintlastic Poly SMS
Base Sheet
Trufast FM-90
Base Sheet
Fasteners
7-inch o.c. at the 4-inch lap and 7-inch
o.c. in two (2), equally spaced,
staggered center rows
(Optional)
BP-CA3 or
SBS-CA3
SBS-CA3 -60.0
MEARLCRETE (FL13492):
CONVENTIONAL SYSTEMS:
LWC-99
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
None Min. 250 psi, min 2-
inch Mearlcrete. None
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet, Flintlastic Poly
SMS Base Sheet
OMG CR Base Ply
Fasteners (1.7)
7-inch o.c. at the 4-inch lap and 7-inch
o.c. in two (2), equally spaced,
staggered center rows
(Optional)
BP-AA or
SBS-AA
SBS-AA, SBS-
TA or APP-
TA
-45.0
LWC-100
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
None Min. 250 psi, min 2-
inch Mearlcrete. None Flintlastic Poly SMS
Base Sheet
OMG CR Base Ply
Fasteners (1.7)
7-inch o.c. at the 4-inch lap and 7-inch
o.c. in two (2), equally spaced,
staggered center rows
(Optional)
BP-AA or
SBS-AA
SBS-AA, SBS-
TA or APP-
TA
-52.5
LWC-101
Min. 22 ga., Type
BV, Grade 33
steel, 5 ft span or
structural
concrete
None Min. 300 psi, min 2-
inch Mearlcrete. None
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet, Flintlastic Poly
SMS Base Sheet
OMG CR Base Ply
Fasteners (1.7)
7-inch o.c. at the 4-inch lap and 7-inch
o.c. in two (2), equally spaced,
staggered center rows
(Optional)
BP-AA or
SBS-AA
SBS-AA, SBS-
TA or APP-
TA
-52.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 60 of 75
TABLE 4F: LIGHTWEIGHT CONCRETE DECKS – REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Surfacing Base Fasteners Spacing Base Ply Cap Ply
PRE-EXISTENT CELLULAR LWC:
LWC-102
Min. 22 ga.,
Type BV,
Grade 40 steel
Min. 470 psi, Min. 2-inch
thick, existing (> 28 days
old) cellular lightweight
concrete
For reroof (tear-off), repair
LWC spalls with Celcore SBS
(Sanded Bonding Surface)
Flintlastic
Ultra Poly
SMS Base
Sheet
Trufast Versa Fasteners
(min. 2.25”) & Plates, two
(2) screws per plate at
180° from each other*
9-inch o.c. within the
min. 5-inch wide,
heat-welded side
laps
(Optional) SBS-TA or
APP-TA SBS-TA or APP-TA -75.0
Note: *Field withdrawal resistance testing (Note 11) shall yield minimum 322 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal
resistance. For recover installations, screws shall be of sufficient length for minimum 2.25” embedment into the existing LWC assembly.
TABLE 4G: LIGHTWEIGHT CONCRETE DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System
No. Deck (Note 1) Lightweight Concrete (Note 14) Roof Cover (Note 15) MDP
(psf) Type Surfacing Base Ply Cap Ply
PRE-EXISTENT CELLULAR LWC:
LWC-103
Min. 22 ga.,
Type BV,
Grade 40 steel
Min. 400 psi, Min. 2-
inch thick, existing (>
28 days old) cellular
lightweight concrete
Repair LWC spalls
with Celcore SBS
(Sanded Bonding
Surface)
Flintlastic Ultra Poly SMS Base Sheet applied in HB
Fuller “Millennium Hurricane Force Membrane
Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide
side laps and 6-inch wide end laps are hot-air-welded,
torch-welded or sealed with HB Fuller “Millennium
Hurricane Force Lap and Flashing Adhesive”
SBS-CA1 or SBS-CA4 -75.0
LWC-104
Min. 22 ga.,
Type BV,
Grade 40 steel
Min. 400 psi, Min. 2-
inch thick, existing (>
28 days old) cellular
lightweight concrete
Repair LWC spalls
with Celcore SBS
(Sanded Bonding
Surface)
Flintlastic Ultra Poly SMS Base Sheet applied in HB
Fuller “Millennium Hurricane Force Membrane
Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide
side laps and 6-inch wide end laps are hot-air-welded,
torch-welded or sealed with HB Fuller “Millennium
Hurricane Force Lap and Flashing Adhesive”
Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic
FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar,
Flintlastic GMS or Flintlastic GMS CoolStar, applied in HB Fuller “Millennium
Hurricane Force Membrane Adhesive HS”, continuous ribbons maximum 6-
inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded,
torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and
Flashing Adhesive”
-97.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 61 of 75
TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Notes 1&12)
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
SELF-ADHERING SYSTEMS:
CWF-1. Tectum
Min. 1.5-inch FlintBoard ISO,
ACFoam II, FlintBoard H ISO, H-
Shield
FlintFast QS
(Optional) Additional layer(s) of base
insulation and/or min. 0.25-inch
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board.
FlintFast QS
FlintPrime
QD, Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional) SBS-SA SBS-SA -60.0
CWF-2. Tectum
Min. 1.5-inch FlintBoard ISO,
ACFoam II, FlintBoard H ISO, H-
Shield
FlintFast QS,
6-inch o.c.
(Optional) Additional layer(s) of base
insulation and/or min. 0.25-inch
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board.
FlintFast QS,
6-inch o.c.
FlintPrime
QD, Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional) SBS-SA SBS-SA -90.0
CWF-3.
Existing
Tectum (re-
roof only)
Min. 1.5-inch FlintBoard ISO,
ACFoam II, ENRGY 3 or Multi-
Max FA3
OB500 Min. 0.25-inch DensDeck OB500
FlintPrime
QD, Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional) SBS-SA SBS-SA -45.0*
CWF-4.
Existing
Tectum (re-
roof only)
Min. 1.5-inch FlintBoard ISO,
ACFoam II, ENRGY 3 or Multi-
Max FA3
OB500 Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board OB500 None SBS-SA (Optional) SBS-SA SBS-SA -45.0*
CWF-5. Tectum
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H or min.
1.5-inch Multi-Max FA3, Ultra-
Max
Polyset Board-
Max or
Polyset CR-20
Min. 0.25-inch DensDeck
Polyset
Board-Max
or Polyset
CR-20
FlintPrime
QD, Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional) SBS-SA SBS-SA -52.5
CWF-6. Tectum
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H or min.
1.5-inch Multi-Max FA3, Ultra-
Max
Polyset Board-
Max or
Polyset CR-20
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
Polyset
Board-Max
or Polyset
CR-20
None SBS-SA (Optional) SBS-SA SBS-SA -52.5
HYBRID SYSTEMS:
CWF-7. Tectum
Min. 1.5-inch FlintBoard ISO,
ACFoam II, FlintBoard H ISO, H-
Shield
FlintFast QS
(Optional) Additional layer(s) of base
insulation and/or min. 0.25-inch
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board.
FlintFast QS None SBS-SA-H
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -60.0
CWF-8. Tectum
Min. 1.5-inch FlintBoard ISO,
ACFoam II, FlintBoard H ISO, H-
Shield
FlintFast QS,
6-inch o.c.
(Optional) Additional layer(s) of base
insulation and/or min. 0.25-inch
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board.
FlintFast QS,
6-inch o.c. None SBS-SA-H
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -90.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 62 of 75
TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Notes 1&12)
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
CONVENTIONAL SYSTEMS:
CWF-9. Tectum
Min. 1.5-inch FlintBoard ISO,
ACFoam II, FlintBoard H ISO, H-
Shield
FlintFast QS
Optional additional layers of base
insulation, followed by min. 0.25-inch
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -60.0
CWF-10. Tectum
Min. 1.5-inch FlintBoard ISO,
ACFoam II, FlintBoard H ISO, H-
Shield
FlintFast QS,
6-inch o.c.
Optional additional layers of base
insulation, followed by min. 0.25-inch
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board.
FlintFast QS,
6-inch o.c. None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -90.0
CWF-11.
Existing
Tectum (re-
roof only)
Min. 1.5-inch FlintBoard ISO,
ACFoam II, ENRGY 3 or Multi-
Max FA3
OB500 Min. 0.5-inch Structodek High Density
Fiberboard OB500 None BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
CWF-12.
Existing
Tectum (re-
roof only)
Min. 1.5-inch FlintBoard ISO,
ACFoam II, ENRGY 3 or Multi-
Max FA3
OB500
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board or DensDeck or
DensDeck Prime
OB500 None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
CWF-13. Tectum
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H, min. 1.3-
inch ACFoam III, FlintBoard ISO
Cold or min. 1.5-inch Multi-Max
FA3, Ultra-Max
Polyset Board-
Max or
Polyset CR-20
Min. 0.5-inch Structodek High Density
Fiberboard
Polyset CR-
20 None BP-AA or
SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -52.5
CWF-14. Tectum
Min. 1-inch ENRGY 3, H-Shield,
FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H or min.
1.5-inch Multi-Max FA3, Ultra-
Max
Polyset Board-
Max or
Polyset CR-20
Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board or DensDeck or
DensDeck Prime
Polyset
Board-Max
or Polyset
CR-20
None
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -52.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 63 of 75
TABLE 5B: CEMENTITIOUS WOOF FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
MDP
(psf) Type Fasteners
(Note 11) Attach Type
Attach
(Notes
6,7,8)
Type
Attach
(Notes
6,7,8)
Base Ply Ply Cap Ply
HYBRID SYSTEMS:
CWF-15. Tectum
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet
Trufast Twin
Loc-Nail
Assembled
Fastener (Field
W/D > 80 lbf)
6-inch o.c. at the 4-
inch lap and 10-inch
o.c. in two (2), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
hot
asphalt
(Optional) Min. 0.25-
inch SECUROCK
Gypsum-Fiber Roof
Board
hot
asphalt SBS-SA-H
(Optional)
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
CWF-16. Tectum
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet
Trufast Twin
Loc-Nail
Assembled
Fastener (Field
W/D > 69 lbf)
7-inch o.c. at the 4-
inch lap and 7-inch
o.c. in two (2), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
hot
asphalt
(Optional) Min. 0.25-
inch SECUROCK
Gypsum-Fiber Roof
Board
hot
asphalt SBS-SA-H
(Optional)
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
CONVENTIONAL SYSTEMS:
CWF-17. Existing
Tectum
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet
Trufast Twin
Loc-Nail
Assembled
Fastener (Field
W/D > 80 lbf)
6-inch o.c. at the 4-
inch lap and 10-inch
o.c. in two (2), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
hot
asphalt
Min. 0.75-inch
FescoBoard
(homogeneous) or min.
0.5-inch Structodek
High Density Fiberboard
hot
asphalt
BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-60.0
CWF-18. Existing
Tectum
Glasbase Base Sheet,
Flintlastic Base 20, All
Weather/Empire Base
Sheet
Trufast Twin
Loc-Nail
Assembled
Fastener (Field
W/D > 69 lbf)
7-inch o.c. at the 4-
inch lap and 7-inch
o.c. in two (2), equally
spaced, staggered
center rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
hot
asphalt
Min. 0.75-inch
FescoBoard
(homogeneous) or min.
0.5-inch Structodek
High Density Fiberboard
hot
asphalt
BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 64 of 75
TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply
CWF-19. Existing
Tectum
(Optional) One or more layers,
any combination, loose laid
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
OMG Polymer GypTec
with 3” GypTec Plate
(Field W/D > 180 lbf)
1 per 2.0
ft2 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA,
SBS-TA or APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
CWF-20. Existing
Tectum
(Optional) One or more layers,
any combination, loose laid
Min. 0.25-inch DensDeck or
DensDeck Prime
OMG Polymer GypTec
with 3” GypTec Plate
(Field W/D > 160 lbf)
1 per 1.8
ft2
BP-AA, SBS-AA, SBS-
TA or APP-TA
(Optional) BP-AA, SBS-AA,
SBS-TA or APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
CWF-21. Existing
Tectum
(Optional) One or more layers,
any combination, loose laid
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
Trufast Twin Loc-Nail
Assembled Fasteners
(Field W/D > 180 lbf)
1 per 2.0
ft2 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA,
SBS-TA or APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
CWF-22. Existing
Tectum
(Optional) One or more layers,
any combination, loose laid
Min. 0.25-inch DensDeck or
DensDeck Prime or
SECUROCK Gypsum-Fiber
Roof Board
Trufast Twin Loc-Nail
Assembled Fasteners
(Field W/D > 180 lbf)
1 per 2.0
ft2
BP-AA, SBS-AA, SBS-
TA or APP-TA
(Optional) BP-AA, SBS-AA,
SBS-TA or APP-TA
SBS-AA, SBS-
TA or APP-TA -45.0*
TABLE 5D: CEMENTITOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR REROOF
SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 15) MDP
(psf) Base Fasteners (Note 11) Attach Base Ply Cap Ply
SELF-ADHERING SYSTEMS:
CWF-23. Tectum Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled
Fastener (Field W/D > 80 lbf)
6-inch o.c. at the 4-inch lap and 10-inch o.c. in two
(2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0
CWF-24. Tectum Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled
Fastener (Field W/D > 69 lbf)
7-inch o.c. at the 4-inch lap and 7-inch o.c. in two
(2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0
CONVENTIONAL SYSTEMS:
CWF-25.
Existing
Tectum
(reroof only)
All Weather/Empire Base Sheet
Trufast Insuldeck Loc-Nail Base
Sheet Fastener (Field W/D > 53
lbf)
9-inch o.c. at the 4-inch lap and 12-inch o.c. in two
(2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -30.0*
CWF-26.
Existing
Tectum
(reroof only)
All Weather/Empire Base Sheet
Trufast Insuldeck Loc-Nail Base
Sheet Fastener (Field W/D > 55
lbf)
7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in
two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -45.0*
CWF-27. Tectum Glasbase Base Sheet, Flintlastic Base 20, All
Weather/Empire Base Sheet
Trufast Twin Loc-Nail Assembled
Fastener (Field W/D > 80 lbf)
6-inch o.c. at the 4-inch lap and 10-inch o.c. in two
(2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA, SBS-TA
or APP-TA -60.0
CWF-28. Tectum Glasbase Base Sheet, Flintlastic Base 20 or
All Weather/Empire Base Sheet
Trufast Twin Loc-Nail Assembled
Fastener (Field W/D > 77 lbf)
7-inch o.c. at the 4-inch lap and 7-inch o.c. in two
(2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA, SBS-TA
or APP-TA -67.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 65 of 75
TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
SELF-ADHERING SYSTEMS:
G-1.
Existing sound
gypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard ISO,
ACFoam III, FlintBoard ISO Cold, ENRGY 3, H-
Shield, FlintBoard ISOH, H-Shield CG,
FlintBoard ISO Cold H
FlintFast QS Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board FlintFast QS SBS-SA (Optional) SBS-SA SBS-SA -172.5
G-2.
Existing sound
gypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard ISO,
ENRGY 3, Multi-Max FA3 FlintFast QS
Min. 0.25-inch DensDeck
primed with FlintPrime QD,
Karnak #108 or ASTM D41
primer
FlintFast QS SBS-SA (Optional) SBS-SA SBS-SA -192.5
G-3.
Existing sound
gypsum or
gypsum plank
One or more layer(s), min. 1.5-inch thick
ACFoam II, FlintBoard ISO, ACFoam III,
FlintBoard ISO Cold, H-Shield, FlintBoard
ISOH, H-Shield CG, FlintBoard ISO Cold H
FlintFast LV Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board FlintFast LV SBS-SA (Optional) SBS-SA SBS-SA -172.5
G-4.
Existing sound
gypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard ISO,
ENRGY 3 OB500
Min. 0.25-inch DensDeck
primed with FlintPrime QD,
Karnak #108 or ASTM D41
primer
OB500 SBS-SA (Optional) SBS-SA SBS-SA -135.0
G-5.
Existing sound
gypsum or
gypsum plank
One or more layer(s), min. 1.5-inch thick
ACFoam II, FlintBoard ISO, ACFoam III,
FlintBoard ISO Cold, H-Shield, FlintBoard
ISOH, H-Shield CG, FlintBoard ISO Cold H
OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA SBS-SA -172.5
G-6.
Existing sound
gypsum or
gypsum plank
One or more layer(s), min. 1.5-inch thick
ACFoam II, FlintBoard ISO, ACFoam III,
FlintBoard ISO Cold, H-Shield, FlintBoard
ISOH, H-Shield CG, FlintBoard ISO Cold H
Polyset Board-
Max
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Polyset Board-
Max SBS-SA (Optional) SBS-SA SBS-SA -172.5
G-7.
Existing sound
gypsum or
gypsum plank
One or more layer(s), min. 1-inch H-Shield,
FlintBoard ISOH, ENRGY 3, ISO 95+GL, min.
1.3-inch ACFoam III, FlintBoard ISO Cold or
min. 1.5-inch ACFoam II, FlintBoard ISO,
Multi-Max FA3, Ultra-Max
Polyset CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Polyset CR-20 SBS-SA (Optional) SBS-SA SBS-SA -172.5
G-8.
Existing sound
gypsum or
gypsum plank
min. 1-inch H-Shield, FlintBoard ISOH, ENRGY
3, ISO 95+GL, min. 1.3-inch ACFoam III,
FlintBoard ISO Cold or min. 1.5-inch ACFoam
II, FlintBoard ISO, Multi-Max FA3, Ultra-Max
Polyset CR-20
Min. 0.25-inch DensDeck
primed with FlintPrime QD,
Karnak #108 or ASTM D41
primer
Polyset CR-20 SBS-SA (Optional) SBS-SA SBS-SA -192.5
HYBRID SYSTEMS:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 66 of 75
TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
G-9.
Existing sound
gypsum or
gypsum plank
One or more layer(s), min. 1.5-inch thick
ACFoam II, FlintBoard ISO, ACFoam III,
FlintBoard ISO Cold, H-Shield, FlintBoard
ISOH, H-Shield CG, FlintBoard ISO Cold H
FlintFast QS,
FlintFast LV,
OB500, Polyset
Board-Max,
Polyset CR-20
(Optional) Min. 0.25-inch
SECUROCK Gypsum-Fiber
Roof Board
FlintFast QS,
FlintFast LV,
OB500, Polyset
Board-Max,
Polyset CR-20
SBS-SA-H (Optional) SBS-AA,
SBS-TA or APP-TA
SBS-AA, SBS-
TA or APP-TA -187.5
CONVENTIONAL SYSTEMS:
G-10.
Existing sound
gypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard ISO,
ENRGY 3, H-Shield, FlintBoard ISOH FlintFast QS Min. 0.5-inch Structodek
High Density Fiberboard FlintFast QS BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -127.5
G-11.
Existing sound
gypsum or
gypsum plank
One or more layer(s), min. 1.5-inch thick
ACFoam II, FlintBoard ISO, ACFoam III,
FlintBoard ISO Cold, H-Shield, FlintBoard
ISOH, H-Shield CG, FlintBoard ISO Cold H
FlintFast QS Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board FlintFast QS
BP-AA or SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -187.5
G-12.
Existing sound
gypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard ISO,
ENRGY 3, H-Shield, FlintBoard ISOH FlintFast QS Min. 0.25-inch DensDeck FlintFast QS BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -232.5
G-13.
Existing sound
gypsum or
gypsum plank
Min. 2-inch ACFoam II, FlintBoard ISO,
ENRGY 3, H-Shield, FlintBoard ISOH FlintFast QS Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board FlintFast QS
BP-AA or SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -202.5
G-14.
Existing sound
gypsum or
gypsum plank
One or more layer(s), min. 1.5-inch thick
ACFoam II, FlintBoard ISO, ACFoam III,
FlintBoard ISO Cold, H-Shield, FlintBoard
ISOH, H-Shield CG, FlintBoard ISO Cold H
FlintFast LV Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board FlintFast LV
BP-AA or SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -187.5
G-15.
Existing sound
gypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard ISO,
ENRGY 3, H-Shield, FlintBoard ISOH OB500 Min. 0.5-inch Structodek
High Density Fiberboard OB500 BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -120.0
G-16.
Existing sound
gypsum or
gypsum plank
Min. 1.5-inch ACFoam II, FlintBoard ISO,
ENRGY 3, H-Shield, FlintBoard ISOH OB500
Min. 0.25-inch DensDeck,
DensDeck Prime or
SECUROCK Gypsum-Fiber
Roof Board
OB500
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -135.0
G-17.
Existing sound
gypsum or
gypsum plank
One or more layer(s), min. 1.5-inch thick
ACFoam II, FlintBoard ISO, ACFoam III,
FlintBoard ISO Cold, H-Shield, FlintBoard
ISOH, H-Shield CG, FlintBoard ISO Cold H
OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -187.5
G-18.
Existing sound
gypsum or
gypsum plank
One or more layer(s), min. 1.5-inch thick
ACFoam II, FlintBoard ISO, ACFoam III,
FlintBoard ISO Cold, H-Shield, FlintBoard
ISOH, H-Shield CG, FlintBoard ISO Cold H
Polyset Board-
Max
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Polyset Board-
Max
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -187.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 67 of 75
TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
G-19.
Existing sound
gypsum or
gypsum plank
Min. 1-inch ENRGY 3, H-Shield, FlintBoard
ISOH, H-Shield CG, FlintBoard ISO Cold H or
min. 1.5-inch Multi-Max FA3, Ultra-Max
Polyset CR-20 Min. 0.25-inch DensDeck or
DensDeck Prime Polyset CR-20 SBS-TA (Optional) SBS-TA SBS-TA -180.0
G-20.
Existing sound
gypsum or
gypsum plank
Min. 1-inch ENRGY 3, H-Shield, FlintBoard
ISOH, H-Shield CG, FlintBoard ISO Cold H or
min. 1.5-inch Multi-Max FA3, Ultra-Max
Polyset CR-20 Min. 0.5-inch Structodek
High Density Fiberboard Polyset CR-20 BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
G-21.
Existing sound
gypsum or
gypsum plank
One or more layer(s), min. 1.5-inch thick
ACFoam II, FlintBoard ISO, ACFoam III,
FlintBoard ISO Cold, H-Shield, FlintBoard
ISOH, H-Shield CG, FlintBoard ISO Cold H
Polyset CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Polyset CR-20
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -187.5
G-22.
Existing sound
gypsum or
gypsum plank
Min. 1-inch ENRGY 3, H-Shield, FlintBoard
ISOH, H-Shield CG, FlintBoard ISO Cold H or
min. 1.5-inch Multi-Max FA3, Ultra-Max
Polyset CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Polyset CR-20 BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -225.0
G-23.
Existing sound
gypsum or
gypsum plank
Min. 1-inch ENRGY 3, H-Shield, FlintBoard
ISOH, H-Shield CG, FlintBoard ISO Cold H or
min. 1.5-inch Multi-Max FA3, Ultra-Max
Polyset CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Polyset CR-20 SBS-TA or
APP-TA
(Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -232.5
G-24.
Existing sound
gypsum or
gypsum plank
Min. 1-inch ENRGY 3, H-Shield, FlintBoard
ISOH, H-Shield CG, FlintBoard ISO Cold H or
min. 1.5-inch Multi-Max FA3, Ultra-Max
Polyset CR-20 Min. 0.25-inch DensDeck Polyset CR-20 BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -240.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 68 of 75
TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
MDP
(psf) Type Fasteners
(Note 11) Attach Type Attach Type Attach Base Ply Ply Cap Ply
HYBRID SYSTEMS:
G-25.
Existing sound
gypsum or
gypsum plank
Glasbase Base
Sheet, Flintlastic
Base 20, All
Weather/Empire
Base Sheet
Trufast Twin Loc-
Nail Assembled
Fastener (Field
W/D > 80 lbf)
6-inch o.c. at the 4-
inch lap and 10-inch
o.c. in two (2),
equally spaced,
staggered center
rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
hot
asphalt None N/A SBS-SA-
H
(Optional)
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
G-26.
Existing sound
gypsum or
gypsum plank
Glasbase Base
Sheet, Flintlastic
Base 20, All
Weather/Empire
Base Sheet
Trufast Twin Loc-
Nail Assembled
Fastener (Field
W/D > 69 lbf)
7-inch o.c. at the 4-
inch lap and 7-inch
o.c. in two (2),
equally spaced,
staggered center
rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
hot
asphalt None N/A SBS-SA-
H
(Optional)
SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
CONVENTIONAL SYSTEMS:
G-27.
Existing sound
gypsum or
gypsum plank
All Weather/Empire
Base Sheet
Trufast FM-75 or
FM-90 Base
Sheet Fastener
or Twin Loc-Nail
Assembled
Fastener (Field
W/D > 100 lbf)
9-inch o.c. at the 4-
inch lap and 18-inch
o.c. in two (2),
equally spaced,
staggered center
rows
(Optional) Min. 1.5-
inch ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
hot
asphalt
Min. 0.75-inch
FescoBoard
(homogeneous) or min.
0.5-inch Structodek
High Density Fiberboard
hot
asphalt
BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
G-28.
Existing sound
gypsum or
gypsum plank
Glasbase Base
Sheet, Flintlastic
Base 20, All
Weather/Empire
Base Sheet
Trufast Twin Loc-
Nail Assembled
Fastener (Field
W/D > 80 lbf)
6-inch o.c. at the 4-
inch lap and 10-inch
o.c. in two (2),
equally spaced,
staggered center
rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
hot
asphalt
Min. 0.75-inch
FescoBoard
(homogeneous) or min.
0.5-inch Structodek
High Density Fiberboard
hot
asphalt
BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-60.0
G-29.
Existing sound
gypsum or
gypsum plank
Glasbase Base
Sheet, Flintlastic
Base 20, All
Weather/Empire
Base Sheet
Trufast Twin Loc-
Nail Assembled
Fastener (Field
W/D > 69 lbf)
7-inch o.c. at the 4-
inch lap and 7-inch
o.c. in two (2),
equally spaced,
staggered center
rows
Min. 1.5-inch
ACFoam II,
FlintBoard ISO,
ENRGY 3 or Multi-
Max FA3
hot
asphalt
Min. 0.75-inch
FescoBoard
(homogeneous) or min.
0.5-inch Structodek
High Density Fiberboard
hot
asphalt
BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 69 of 75
TABLE 6C: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply
G-30.
Existing sound
gypsum or
gypsum plank
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation
OMG Polymer GypTec with 3”
GypTec Plate (Field W/D > 180
lbf)
1 per 2.0 ft2 BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
G-31.
Existing sound
gypsum or
gypsum plank
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch DensDeck or
DensDeck Prime
OMG Polymer GypTec with 3”
GypTec Plate (Field W/D > 160
lbf)
1 per 1.8 ft2
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
G-32.
Existing sound
gypsum or
gypsum plank
(Optional) One or more
layers, any combination,
loose laid
Min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation
Trufast Twin Loc-Nail Assembled
Fasteners (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA or SBS-
AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
G-33.
Existing sound
gypsum or
gypsum plank
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch DensDeck or
DensDeck Prime or
SECUROCK Gypsum-Fiber
Roof Board
Trufast Twin Loc-Nail Assembled
Fasteners (Field W/D > 180 lbf) 1 per 2.0 ft2
BP-AA, SBS-
AA, SBS-TA or
APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
TABLE 6D: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 15) MDP
(psf) Base Fasteners (Note 11) Attach Base Ply Cap Ply
SELF-ADHERING SYSTEMS:
G-34. Existing sound gypsum
or gypsum plank Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled
Fastener (Field W/D > 80 lbf)
6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2),
equally spaced, staggered center rows SBS-SA SBS-SA -60.0
G-35. Existing sound gypsum
or gypsum plank Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled
Fastener (Field W/D > 88 lbf)
9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2),
equally spaced, staggered center rows SBS-SA SBS-SA -60.0
CONVENTIONAL SYSTEMS:
G-36. Existing sound gypsum
or gypsum plank All Weather/Empire Base Sheet
Trufast FM-75 or FM-90 Base
Sheet Fastener or Twin Loc-Nail
Assembled Fastener (Field W/D >
100 lbf)
9-inch o.c. at the 4-inch lap and 18-inch o.c. in two (2),
equally spaced, staggered center rows
BP-AA or SBS-
AA SBS-AA -45.0*
G-37. Existing sound gypsum
or gypsum plank
Glasbase Base Sheet, Flintlastic
Base 20, All Weather/Empire Base
Sheet
Trufast Twin Loc-Nail Assembled
Fastener (Field W/D > 80 lbf)
6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2),
equally spaced, staggered center rows
BP-AA or SBS-
AA
SBS-AA, SBS-
TA or APP-TA -60.0
G-38. Existing sound gypsum
or gypsum plank
Glasbase Base Sheet, Flintlastic
Base 20, All Weather/Empire Base
Sheet
Trufast Twin Loc-Nail Assembled
Fastener (Field W/D > 100 lbf)
9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2),
equally spaced, staggered center rows
BP-AA or SBS-
AA
SBS-AA, SBS-
TA or APP-TA -67.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 70 of 75
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Substrate (Notes 1 & 12)
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
SELF-ADHERING SYSTEMS:
R-1 Existing fully bonded BUR or
modified bitumen roof cover
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH or Multi-
Max FA3
hot asphalt Min. 0.25-inch DensDeck hot asphalt
FlintPrime
QD, Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -105.0
R-2 Existing fully bonded BUR or
modified bitumen roof cover
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH or Multi-
Max FA3
hot asphalt Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board hot asphalt None SBS-SA (Optional)
SBS-SA SBS-SA -105.0
R-3
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.5-inch ACFoam-HD
Coverboard or H-Shield HD
FlintFast QS or
FlintFast LV
FlintPrime
QD, Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -97.5
R-4
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV None SBS-SA (Optional)
SBS-SA SBS-SA -172.5
R-5
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, ENRGY 3, Multi-
Max FA3
FlintFast QS or
FlintFast LV Min. 0.25-inch DensDeck FlintFast QS or
FlintFast LV
FlintPrime
QD, Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -192.5
R-6
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV, 6-
inch o.c.
Min. 0.5-inch ACFoam-HD
Coverboard or H-Shield HD
FlintFast QS or
FlintFast LV, 6-
inch o.c.
FlintPrime
QD, Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -315.0
R-7
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV, 6-
inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV, 6-
inch o.c.
ASTM D41
or Karnak
#108
Asphalt
Primer
SBS-SA (Optional)
SBS-SA SBS-SA -315.0
R-8 Existing fully bonded BUR or
modified bitumen roof cover
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500
FlintPrime
QD, Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -120.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 71 of 75
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Substrate (Notes 1 & 12)
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-9 Existing fully bonded BUR or
modified bitumen roof cover
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, ENRGY 3 OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional)
SBS-SA SBS-SA -120.0
R-10
Existing fully-bonded smooth- or
granule-surface asphalt BUR or
granule-surface modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset Board-
Max
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Polyset Board-
Max None SBS-SA (Optional)
SBS-SA SBS-SA -172.5
R-11
Existing fully-bonded smooth- or
granule-surface asphalt BUR or
granule-surface modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset Board-
Max Min. 0.25-inch DensDeck Polyset Board-
Max
FlintPrime
QD, Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -192.5
R-12
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Polyset CR-20 None SBS-SA (Optional)
SBS-SA SBS-SA -172.5
R-13
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset CR-20 Min. 0.25-inch DensDeck Polyset CR-20
FlintPrime
QD, Karnak
#108 or
ASTM D41
primer
SBS-SA (Optional)
SBS-SA SBS-SA -192.5
HYBRID SYSTEMS:
R-14 Existing fully bonded BUR or
modified bitumen roof cover
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH or Multi-
Max FA3
hot asphalt Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board hot asphalt None SBS-SA-H
(Optional)
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-105.0
R-15
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.5-inch ACFoam-HD
CoverBoard or H-Shield HD
FlintFast QS or
FlintFast LV None SBS-SA-H
(Optional)
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-97.5
R-16
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV
(Optional) Additional
layer(s) base insulation
FlintFast QS or
FlintFast LV None SBS-SA-H
(Optional)
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-210.0
R-17
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV None SBS-SA-H
(Optional)
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-210.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 72 of 75
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Substrate (Notes 1 & 12)
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-18
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV, 6-
inch o.c.
Min. 0.25-inch DensDeck
Prime or SECUROCK
Gypsum-Fiber Roof Board or
min. 0.5-inch ACFoam-HD
CoverBoard or H-Shield HD
FlintFast QS or
FlintFast LV, 6-
inch o.c.
None SBS-SA-H
(Optional)
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-315.0
R-19
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, ENRGY 3 OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 None SBS-SA-H
(Optional)
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-120.0
R-20
Existing fully-bonded smooth- or
granule-surface asphalt BUR or
granule-surface modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset Board-
Max
(Optional) Additional
layer(s) base insulation
Polyset Board-
Max None SBS-SA-H
(Optional)
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-195.0
R-21
Existing fully-bonded smooth- or
granule-surface asphalt BUR or
granule-surface modified bitumen
(Optional0 Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset Board-
Max
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Polyset Board-
Max None SBS-SA-H
(Optional)
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-195.0
R-22
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset CR-20 (Optional) Additional
layer(s) base insulation Polyset CR-20 None SBS-SA-H
(Optional)
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-222.5
R-23
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Polyset CR-20 None SBS-SA-H
(Optional)
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-217.5
CONVENTIONAL SYSTEMS:
R-24 Existing fully bonded BUR or
modified bitumen roof cover
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH or Multi-
Max FA3
hot asphalt
Min. 0.5-inch Structodek
High Density Fiberboard,
Min. 0.75-inch FescoBoard
(homogeneous) or Min. 0.5-
inch DuraBoard
(homogeneous)
hot asphalt None BP-AA or
SBS-AA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-105.0
R-25 Existing fully bonded BUR or
modified bitumen roof cover
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH or Multi-
Max FA3
hot asphalt
0.25-inch DensDeck,
DensDeck Prime or
SECUROCK Gypsum-Fiber
Roof Board
hot asphalt None
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-105.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 73 of 75
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Substrate (Notes 1 & 12)
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-26
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.5-inch Structodek
High Density Fiberboard
FlintFast QS or
FlintFast LV None BP-AA or
SBS-AA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-165.0
R-27
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV Min. 0.25-inch DensDeck FlintFast QS or
FlintFast LV None BP-AA or
SBS-AA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-210.0
R-28
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.25-inch DensDeck
Prime
FlintFast QS or
FlintFast LV None
BP-AA,
SBS-AA,
SBS-TA
(Optional)
BP-AA, SBS-
AA or SBS-
TA
SBS-AA or
SBS-TA -210.0
R-29
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 2-inch ACFoam II,
FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV None
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-210.0
R-30
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV, 6-
inch o.c.
Min. 0.25-inch DensDeck
Prime or SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV, 6-
inch o.c.
None SBS-AA or
SBS-TA
(Optional)
SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -315.0
R-31
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV, 6-
inch o.c.
Min. 0.25-inch DensDeck
Prime or SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV, 6-
inch o.c.
None
Flintlastic
STA or
Flintlastic
STA Plus
(Optional)
APP-TA APP-TA -315.0
R-32 Existing fully bonded BUR or
modified bitumen roof cover
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
OB500 Min. 0.5-inch Structodek
High Density Fiberboard OB500 None BP-AA or
SBS-AA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-120.0
R-33 Existing fully bonded BUR or
modified bitumen roof cover
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, ENRGY 3, H-
Shield, FlintBoard ISOH
OB500
Min. 0.25-inch DensDeck,
DensDeck Prime or
SECUROCK Gypsum-Fiber
Roof Board
OB500 None
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-120.0
R-34
Existing fully-bonded smooth- or
granule-surface asphalt BUR or
granule-surface modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset Board-
Max Min. 0.25-inch DensDeck Polyset Board-
Max None BP-AA or
SBS-AA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-195.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 74 of 75
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Substrate (Notes 1 & 12)
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-35
Existing fully-bonded smooth- or
granule-surface asphalt BUR or
granule-surface modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset Board-
Max
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Polyset Board-
Max None
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-195.0
R-36
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
Min. 1.5-inch ACFoam II,
FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset CR-20 Min. 0.5-inch Structodek
High Density Fiberboard Polyset CR-20 None BP-AA or
SBS-AA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-180.0
R-37
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset CR-20 Min. 0.25-inch DensDeck Polyset CR-20 None BP-AA or
SBS-AA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-222.5
R-38
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Polyset CR-20 None
BP-AA,
SBS-AA,
SBS-TA or
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA or
APP-TA
-222.5
COLD-APPLIED SYSTEMS:
R-39
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.5-inch ACFoam-HD
CoverBoard or H-Shield HD
FlintFast QS or
FlintFast LV None SBS-CA1 None SBS-CA1 -97.5
R-40
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 1.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.5-inch ACFoam-HD
CoverBoard or H-Shield HD
FlintFast QS or
FlintFast LV None SBS-CA4 None SBS-CA4 -97.5
R-41
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 0.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV None SBS-CA1 None SBS-CA1 -105.0
R-42
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 0.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
FlintFast QS or
FlintFast LV
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
FlintFast QS or
FlintFast LV None SBS-CA4 None SBS-CA4 -105.0
R-43 Existing fully bonded BUR or
modified bitumen roof cover
(Optional) Min. 0.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
OB500
Min. 1.5-inch ACFoam III,
FlintBoard Iso Cold, H-Shield
CG or FlintBoard Iso ColdH
OB500 None SBS-CA1 None SBS-CA1 -82.5
R-44
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
(Optional) Min. 0.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 None SBS-CA1 None SBS-CA1 -105.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021
©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 75 of 75
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No. Substrate (Notes 1 & 12)
Base Insulation Layer Top Insulation Layer
Primer
Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-45
Existing fully bonded, smooth- or
granule-surface BUR or modified
bitumen
(Optional) Min. 0.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 None SBS-CA4 None SBS-CA4 -105.0
R-46
Existing fully-bonded smooth- or
granule-surface asphalt BUR or
granule-surface modified bitumen
(Optional) Min. 0.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset Board-
Max
Min. 1.5-inch ACFoam III,
FlintBoard Iso Cold
Polyset Board-
Max None SBS-CA1 None SBS-CA1 -82.5
R-47
Existing fully-bonded smooth- or
granule-surface asphalt BUR or
granule-surface modified bitumen
(Optional) Min. 0.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset Board-
Max
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Polyset Board-
Max None SBS-CA1 None SBS-CA1 -105.0
R-48
Existing fully-bonded smooth- or
granule-surface asphalt BUR or
granule-surface modified bitumen
(Optional) Min. 0.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset Board-
Max
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
Polyset Board-
Max None SBS-CA4 None SBS-CA4 -105.0
R-49
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 0.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset CR-20
Min. 1.5-inch ACFoam III,
FlintBoard Iso Cold, H-Shield
CG or FlintBoard Iso ColdH
Polyset CR-20 None SBS-CA1 None SBS-CA1 -82.5
R-50
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 0.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Polyset CR-20 None SBS-CA1 None SBS-CA1 -105.0
R-51
Existing fully-bonded smooth- or
granule-surface asphalt BUR or SBS
modified bitumen or granule-surface
APP modified bitumen
(Optional) Min. 0.5-inch ACFoam
II, FlintBoard ISO, H-Shield,
FlintBoard ISOH
Polyset CR-20 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Polyset CR-20 None SBS-CA4 None SBS-CA4 -105.0
TABLE 7B: RECOVER APPLICATIONS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System
No.
Substrate
(Notes 1 & 12) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply
R-52 Existing fully bonded asphalt built-up roof (BUR) over
structural concrete deck
(Optional) ASTM D41 or Karnak #108 Asphalt