HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM. R405=20.14 ®py
FLORIDA. ENERGY EFFICIENCY CODE. FOR BUILDING .C. ONSTRUCTION.
Florida_ Department of BUsiness•8nd-Professional.Regulation - Residential-P.erfor'ManCe:Method-
Project•Name: THE GRAND CARLTON
Builder Name: WYNNE DEVELOPMENT,
Street: WYNNE DEVELOPMENT
Permit Office; ST.:LUCIE COUNTY
City, State. -Zip: FT.:PIERCE : FL
' Owner.. �� �1.�. �Q `� 5 .
P0mit'Number.
_ Jurisdiction: .
Design•Locatiom • FL, ST LUCIE=CO_INTL.
County:: ST: LUCIE COUNTY (Florida Climate Zone 2 )-
1:: New construction or•existing - .: New (From.Plans)
9. Wall Types(1437.3•_sgft.)
Insulation Area
2. Single family or multiple family Single,family
a: Concrete Block - E)t Insul, Exterior
R=4,1 1250.00 ftz
3:. Number of -units, if multiple family 1
b. Frame - Wood,-Extedor
c. NIA
R=11.0- 187.33 it= -
R= t.
4. Number of•Bedrooms : - 2:
R= : ft=
5: Is this a worst case?- yes :
j0..Ceilirig-Types•.(1446.0 sgft.) .=
Insulation Area
a; Under Attic (Vented) :
R=30:0 . 1446.00 fe
6. Conditioned floor area above grade (ft2) 1446
b. N/A-'.
R=
Conditioned floor area below grade (ft� 0
c. N/A
Ft= ft=
.
1
7c. Windows(139:2 sgft) Description Area
a Sup Attic, Ret: Attic, AH:. Attic-
6 320.
a. U-Factor Dbl, U4:54 . 99.23 fie
SHGC: SHGC=O-25
b. U-Faetor ml, U=0.55 40.00 fe
12: Cooling systems
kBtuihr Efficiency
SHGC: - SHGC=0.25
a. Central'Unft
34.8 SEER:15.b0
. .
c. U-Factor.. NIA. .:. ft?
SHGC;
11 Heating systems
kBtAr )Efficiency.'
d. U-Factor: NIA. ft2 , ' •
a. Electric Heat Pump .
34.8 HSRF:8,50
SHGC:
Area Weighted Average Overhang Depth:: 3.586 ft
.:Area WeightedAyerage _SHGC: _... 0.250
.1:4: Hotwatersystems. . .
8. Floor Types (1446.0 SCA) 'Insulation Area
a.Electrio
Cap: 40 gallons .
a: Sla"n-Grade Edge Insulation. R=0.0 .1446.0010,
-.
b. Conservation features
ER 0.970
b. N/A . R= itx
None . .
c. NIA : R= ftZ
15: Credits-.. .. ....
Pstat
-. Total Proposed Modified .Loads: 46.91 -
. Glass/Floor Area: 0.096
PASS
Total Baseline Loads: 48.19
I hereby certify that. the plans and specifications -covered by-
Review of the plans and -
Z01E ST,t
this calculation are in compliance with the' Florida Energy
speciflcatioiis.covered by this
Code.
calculation indicates: compliance
wifti the Florida Energy -Code..:
PREP
"Beore onstoiscompeted:
C .
DATE: �-^•-
this building will be inspected for
compliance with Section 553.908
Thereby certify:that this. building, as designed, is in compliance - .
Florida Statutes,
with•the Florida Energy Code: ..
OWNE iT:
BUILDING. OFFICIAL:
`yF•,�'"
DATE:
DATE:
-Compliance requires -certification by the air handler, unit manufacturer that the air. handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
Compliance requires an Air Barrier and.'Insulation 1rispection Checklist in accordance with R402.4.1.1 and. an•envelop0 leakage
test report, irli.accordance with R402.4.1.2.
6/16/201711:49 AM EnergyGauge® USA = FlaRes2014 Section R405.4.1 Compliant Software Pagel of 5
FORM'R405-2014
PROJECT
Title: THE GRAND CARLTON Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1446
Lot #
Owner:
Total Stories: 1
Block/SubDivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 135
Street:
WYNNE DEVELOPME
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
ST. LUCIE COUNTY
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
IECC Design Temp
Int Design Temp
Heating
Design Daily Temp
v Design Location
TMY Site Zone 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 2 39
90
70
75
299
58
Medium
BLOCKS
Number Name
Area Volume
1 Entire House
1446 11568
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 BEDROOM
234 1872 No
2
1
1
Yes
Yes
Yes
2 WIC
54 432 No
0
1
No
Yes
Yes
3 MASTER BATH
63 504 No
0
1
Yes
Yes
Yes
4 M.BATH
56 448 No
0
1
Yes
Yes
Yes
5 KITCHEN
172 1376 Yes
0
1
No
Yes
Yes
6 BATH
45 360 No
0
1
Yes
Yes
Yes
7 BEDROOM 2
204 1632 No
1
1
1
Yes
Yes
Yes
8 LAUNDRY
42 336 No
0
1
Yes
Yes
Yes
9 GREAT/DINING
526 4208 No
0
1
Yes
Yes
Yes
10 FOYER
50 400 No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 40 ft 0
234 ftZ
____
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
54 ft2
_—_
0 1
0
3 Slab -On -Grade Edge Insulatio
MASTER BATH 9 ft 0
63 ftZ
0 1
0
4 Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ftz
____
0 1
0
5 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft 0
172 ftZ
__-_
0 1
0
6 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
45 ftz
_—_
0 1
0
7 Slab -On -Grade Edge Insulatio
BEDROOM 2 34.2 ft 0
204 ftz
0 1
0
6/16/2017 11:49 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FOR KA R405-?014
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 47 ft
0
526 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio FOYER 7 ft
0
50 ft2
----
0
1
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
#
Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1
Gable or shed Metal 1524 ft2
240 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1446 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) BEDROOM
30
Blown
234 ft2
0.1
Wood
2
Under Attic (Vented) WIC
30
Blown
54 ft2
0.1
Wood
3
Under Attic (Vented) MASTER BATH
30
Blown
63 ft2
0.1
Wood
4
Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
5
Under Attic (Vented) KITCHEN
30
Blown
172 ft2
0.1
Wood
6
Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
7
Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
8
Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9
Under Attic (Vented) GREAT/DINING
30
Blown
526 ft2
0.1
Wood
10
Under Attic (Vented) FOYER
30
Blown
50 ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width
In Wall Type Et In
Height
Et In
Area
Sheathing Framing
R-Vahle Fraction
Solar
Ahsor
BeloOrnt w
Grarie%
1
N=>SE
Exterior Concrete Block - Ext lnsdBEDROOM
4.1 9
0 8
0
72.0 ft2
0
0
0.5
0
2
S=>NW
Exterior Concrete Block - Ext InsdBEDROOM
4.1 18
0 8
0
144.0 ft2
0
0
0.5
0
3
W=>NE
Exterior Concrete Block - Ext Insd3EDROOM
4.1 13
0 8
0
104.0 ft2
0
0
0.5
0
_ 4
S=>NW
Exterior Concrete Block - Ext InsMASTER BA
4.1 9
0 8
0
72.0 ft2
0
0
0.5
0
5
S=>NW
Exterior Concrete Block - Ext Insuh/l. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.5
0
6
N=>SE
Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.5
0
7
N=>SE
Exterior Concrete Block - Ext InfiffDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.5
0
8
E=>SW
Exterior Concrete Block - Ext InEEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.5
0
9
SE=>W
Exterior Concrete Block - Ext IndeEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.5
0
10
S=>NW
Exterior Concrete Block - Ext InBEDROOM 2
4.1 4
0 8
0
32.0 ft2
0
0
0.5
0
11
S=>NW
Exterior Concrete Block - Ext InSil1AUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.5
0
12
N=>SE
Exterior Concrete Block - Ext InsGREAT/DINT
4.1 26
0 8
0
208.0 ft2
0
0
0.5
0
6/1/2017 8:43 AM EnergyGauge(D USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM'R405-2014
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
13 W=>NE Exterior Concrete Block - Ext InsGREAT/DINT 4.1 21 0 8
14 N=>SE Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8
15 E=>SW Exterior Concrete Block - Ext Insul FOYER 4.1 6 0 8
16 N=>SE Exterior Frame - Wood GREAT/DINI 11 23 5 8
0 168.0 ft2
0 8.0 ft2
0 48.0 ft2
187.3 ft2
0 0 0.5
0 0 0.5
0 0 0.5
0.23 0.5
0
0
0
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Ft
Width Height
In Ft In
Area
1 E=>SW Insulated FOYER
None
.28 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
V # Ornt ID Frame Panes NFRC
U-Factor SHGC
Overhang
Area Depth Separation Int Shade
Screening
1 W=>NE 3 Metal Low-E Double Yes
2 S=>NW 5 Metal Low-E Double Yes
3 E=>SW 8 Metal Low-E Double Yes
4 N=>SE 12 Metal Low-E Double Yes
5 W=>NE 13 Metal Low-E Double Yes
0.54 0.25
0.54 0.25
0.54 0.25
0.54 0.25
0.55 0.25
32.4 ft2 1 ft 0 in
6.9 ft2 1 ft 0 in
23.2 ft2 1 ft 0 in
36.8 ft2 1 ft 0 in
40.0 ft2 10 ft 0 in
1 ft 4 in Drapes/blinds
1 ft 4 in None
1 ft 4 in None
1 ft 4 in None
1 ft4 in None
Exterior 5
None
None
None
None
1
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 315ft2 315ft2
24ft
8ft
11
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356
1349.6 74.09 139.34 .2455
7
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type Subtype
Efficiency
Capacity Air Flow SHR Block
Ducts
1 Central Unit Split
SEER: 15 34.8 kBtu/hr
cfm 0.85 1
sys#1
6/1/2017 8:43 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM 'R4 J5-2014
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector
Model
# Area
Volume
FEF
None
None
ftZ
DUCTS
---- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 320 ftz
Attic
80 ft2 Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
Feb
]Mar
A r
Ma X Jun X Jul
Au
Se
Oct
Nov
Dec
HeatinX Jan
X Feb
X] Mar
f
AprJMayJun
4 Jul
Au
rj
Sep
rl
Oct
X� Nov
Dec
Ventin [ Jan
[ Feb
X Mar
X A r [
Ma [ Jun [ Jul
Aug
Se
[X]
Oct
[X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
6/1/2017 8:43 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: THE GRAND CARLTON Builder Name: WYNNE, DEVELOPMENT
Street: WYNNE DEVELOPMENT Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, ST LUCIE_CO_INTL
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
s aces.
Garage separation.
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
6/16/201711:54 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
e
FORM IR405-2014
ENERGY PERFORMANCE LEVEL
(EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
WYNNE DEVELOPMENT, FT. PIERCE, FL,
1. New construction or existing
New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Ext Insul, Exterior R=4:1
1250.00 ftz
b. Frame - Wood, Exterior
R=11.0
187.33 ftz
3. Number of units, if multiple family
1 c. N/A
R=
ftz
4. Number of Bedrooms
2 d. N/A
R=
ftz
5. Is this a worst case?
Yes 10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
1446.00 ft z
6. Conditioned floor area (ftz)
1446 b. N/A
R=
ftz
7. Windows- Description
Area c. N/A
R=
ft z
a. U-Factor: Dbl, U=0.54
99.23 ftz 11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ftz
6 320
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.55
40.00 ftz
SHGC: SHGC=0.25
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ftz a. Central Unit
34.8 SEER:15.00
SHGC:
d. U-Factor: N/A
ftz
SHGC:
13. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
34.8
HSPF:8.50
Area Weighted Average Overhang Depth:
3.586 ft.
Area Weighted Average SHGC:
0.250
8. Floor Types
Insulation Area 14. Hot water systems
Cap:
40 gallons
a. Slab -On -Grade Edge Insulation
R=0.0 1446.00 ftz a. Electric
EF: 0.97
b. N/A
R= ftz
C. N/A
R= ftz b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:j
Address of New Home: �� j�� �Q�` G City/FL Zip�C+C{,
c
COD tiVE ��
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/1/2017 8:43 AM EnergyGauge@ USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
�o�