-- wrightsoft® 317 ST. LUCIE LN., FT. Project Summary pat Entire House By: QUICK CALCS, INC. FL 34946 Phone: 772-466-6799 Fax 772.466-6796 Email: QUICKCALCSQA0L.00M For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Notes: \� � �\ �C\, Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm)- 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Rate/swingg multiplier 0.95 Infiltration Equipment sensible load 24753 Btuh Method Simplified Latent Cooling Equipment Load, Sizing Construction quality Average Fireplaces 0 Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 1446 1446 Equipment latent load 5521 Btuh Volume (ft3) 12511 12511 Air changeslhour 0.45 0.23 Equipment total load 30274 Btuh Equiv. AVF (cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A" 030 Cond 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling. 24360 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27 . °F Total cooling 34800 Btuh Actual air flow 1160 cfm Actual air flow 1160 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 32 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. " wrightsoft` 2017-Apr-11 09:29:38 Right -Suite® Universal 201717.0.14 RSU08101 Page 1 ACCA ..uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N wrightsofr Right-.J@ Workshe6t Job: Entire House Date: By: QUICK CALCS, INC.* 317 ST. LUCIE LN., FT PIERCE, FL 34946-Phone: 772466-6799 Fax 772-466-6796 Emall:- QUICKCALCS@AOL.COM 1 Room name Entire. House BEDROOM 2 Exposed wall 156.2 ft 49.0 ft a height 8.7 ft d 8.0 ft heaticool 4 5 Room dimensions Room area 1445.5 ft' 1.0 x 297.0 ft 297.0 ft2 Ty Construction Ll-value Or HTM Area (ft2) Load Area (ft2) Load number (BtutVft2-*F) (BtuWft2) or perimeter (ft) (Btu�h) or perimeter (ft) (Btuh) Heat Cool. Gross NIPIS Heat Cool cool :r Gross N/P(S Heat cool 6 t4 -4oci, AM -A� 13AAocs -�,0'14 3 . 0.143 i�'� fi",' e , 4:00 ... .' 51 '16 2.55 128 "�a :�O, 83 1862 .815 333 _.jrj 84 780 212 0 -..'72 0 �`289 0 183 0 11 IIA-clom 11DO 1.270 0.390 e a 35.56 10.92 87.29 11.31 24 21 2 21 848 229 2082 238 0 0 0 0 0 0 0 0 W- Y--G 'A3A4oc6 13AAocs '0143 0.143 se s -4k0 4.00 255 2.55 34' 360 34 353 136 1414 86 899 0- 216 ---0' 216 .6 865 550 IIA-clom '.4Aclorn. 12C-OsW . 6A130m L 'j "d 1.270 -.0.143 1.270': 0.091 0."OM . . a W -W,; w - 35.56 4.'00 .35.56 2.55 : .. 1. 0.. 34.77 '255 -55.211 1.28 'z&7 . - 7 310 -�2 4w 192 144 . -6 7 237 '2 4 192 A446 247 949 1140:,� .660 489 1256 241 '603 .1770 7' 88 246 "32W 0 104 32- 0 0 0 - 72, i `,2 .:-0 0 -20 0 :289 11-40 -'0." 0 2a 0 117w 0 0 6E6 P F- 22,A-tp 1 0.989 27.69 0.00 1446 156 4325 0 297 49 1367 0 W, Z .01 6 c)AED excursion 918 627 Envelope loss/gain 14961 13349 . 4204 4003 12 a), Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 .690 Appliances/other 2000 01 Subtotal (lines 6 to 13) 17848 17520 '6053 :4925 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 1 Duct loads 1 32%1 0% 1 56.94 85361 32% 49% im 2400 Total room load 23503. 26056 l 6653 7325 Air required (cfm) 1160, 1160 — - 328 3261 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigh"pit 20117-Apr-1109:29:38 Right -Suite@ Universal 2017 17.0.14 RSU081011- Page 1 ... -nts\THE GRAND CARLTON-11446.ru ' Calc = MJ8 Front Door faces: N uIck CaleslDocurne p - - wrightsoft' Right-J® WOrksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@10L,COM 1 Room name WIC KITCHEN 2 Exposed wall O ft O ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 6.0 x 9.0 ft 1.0 x 172.0 ft 5 Room area 54.0 ftz 172.0 ftz Ty Construction U-value Or HTM Area(ftz) Load Area (ftz) Load number Btuh/ftz-°F ( ) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A17acs :. 0:143 n 4-00' 2.55 b , 0 0 r G ,4P&2om 0:770 . n" . 21i56 1931: A 0 . °. :. 0 --.0 13A-4ocs 0.143 a 4.00 2.55 0 .0 0 0 0 0 0 0 11 1Ac1om 11D0 .13A-0ocs 13A-4ocs 1Ac1om 13A-0ocs 1Ac1om _4A5 12C-Osw %k-30md` .. 22A-tpl 1.270 0.390 0143 0.143 1.270 0.143 1.270 AM 0.091 '0.032 0.989 a a se, s s w w .w - „ = . - 35.56 10.92 4.00 4.00 35.56 4.00 35:5ti 21.:56 2.55 _0:90 27.69 87.29 11.31 2 55 2.55 34.77 2.55 55.21 19,31 1.28 � -2;32 0.00 0 0 0 0 0 : 0 0 0-- - 0 : 54 54 0 0 0 0 0 0 0 0 0 ; . 54 0 0 0 0 0 0 0 0 0 0 48 0 0 0 .- 0 0 .0 .0 0 . .0 0 '; , 125 0 0 0 0 0 0 0 0 0 64 ..' . 172 172 0 0 0 0 0 01 0 . 0. 64 :. 172 0 0 0 0 0 0 0 0 0 163 :. :. :154 0 0 0 0 0 0 0 0 ; . 0 82 399 0 W. - VI/ -G P C F 6 c)AED excursion-9 -170 Envelope loss/gain 1 481 117 1 3171 311 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal Vines 6 to 13) 48 117 317 2311 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 117 317 2311 15 Duct loads 1 32% 49%1 15 57 32% 49% 100 1126 Total room load 64 174 1 1 418 3437 Air required (cfm) 3 8 21 153 Calculations approved byACCA to meet all requirements of Manual J-8th Ed. A& -11`�- wrightsoft' Right -Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 2 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N f - wrightsoft- Right-M Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6769 Fax 772466-6796 Email: QUICKCALCS@AOL.COM Job: Date: By: 1 Room name BATH BEDROOM 2 2 Bposed wall 5.0 ft 34.2 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 9.0 x .5.0 ft 1.0 x 203.5 ft 5 Room area 45.0 ft' 203.5 ftz Ty Construction U-value Or HTM Area number (Btuh/ft' °F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A4ocs ' 0143 n ` 4,""00 2:55 40 ' . 40 160 : 102 ' 128 : 128 c513 326 t-G. 4A5 2om:::. 0.770 'n' : , " 2158 19:39; ..: .- 0 , 0 `.: ' : 0 0 . ILZ13A-4ocs 0.143 a 4.00 2.55 0 0 0. 0 80 56 225 143 1A-c1om 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082 11 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W .13AAocs 0:143 se 4;00 2:55 0 0 0 _ 0 34 34 136 86 t--C 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 32 32 128 81 1Ac1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A-0ocs 0143 w 4 00 2.55 0' 0 0 .0 0 0. '0 0 1x:biom .. " 1'270 w . 35 5ti. 55.21 .0 0 0 .. . 0 0 . p 0 0 ;9A5 tom , ,0 770 , w 21:56 . 19:31 ' 0 0 0 - . 0 0 , '. "_ "0. , 0 0 P 12C-0sw 0.091. -- 2.55 _ 1.28 . 0 0 6 0 0 0 0 ,. 0 C :1.6A30md ; - 0:032 • _ 0:9D 2 32 45 ; 45 . .40 . - . 104 '" . • 204 204 . :182 472 F 22A tpl 0.989 27.69 0.00 45 5 138 0 204 34 946 0 6 c)AED emursion -16 -85 Envelope loss/gain 339 190 2978 3106 12 a) Infiltration . 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 p Subtotal pines 6 to 13) 425 214 3571 3498 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 . Subtotal 425 214 3571 3498 15 Duct loads 32% 1 49% 135 104 32% 49%1 1131 1704 riTotal room load 560 318 1 4702 5203 Air required (cfm) 281 14 232 232 Calculations approved byACCA to meet all requirements of Manual J.8th Ed. wrightsoft' Right -Suite® Universa1.2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 ACCA ulck Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Page 3 - - wrightsoftRight-J® Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 3 Exposed wall Room height 6.0 ft 8.0 ft heat/cool 47.0 ft 9.8 ft heat1cool 4 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 ft2 1.0 x 526.0 ft 526.0 ft2 Ty Construction U-value Or HTM Area (ft-) Load Area (ftt Load number Btuh/ft2 °F ( ) 2 (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yJ � )3A-4ocs- ; 13A-flocs 0:143 0:776 0.143 n.'- n' a A.00 21<56 4.00 Z65 - 19,31 2.55 .:0 -0 0 0 - 0 0 0 , 0 0 0 0 0 , 255 38 0 ; 217 0 0 869 815 0 552 , 730 0 11 �1-G 1Ac1om 11DO "43A-4ocs 13A-4ocs 1.270 0.390 0.143 0.143 a a se s 35.56 10.92 4:00 4.00 87.29 11.31 2.55 2.55 0 0 0 48 0 0 0 48 0 0 0 192 0 0 0 122 0 0 0 0 0 0 0- 0 0 0 0 0 0 0 0 0 W V�1 L-G 1Aclom -13AA6cs ;1Ac1am 4Ar2om . 12C-Osw .16A-30.md. - 22A-tpl 1.270 0.143 1:276 0;770 0.091. "'0.032 0.989 s w w, ;.. w. " . - 35.56 4.00 35"56. . .21 "56, 2.55 'D:90 27.69 34.77 2.55 55.21 19:31 128, i ': :32 0.00 0 0 •0 0 56 .. 42 42 0 0 0 0 56 _ 42-- 6 0 0 0 0 143 38 166 0 .0 . 0 . - .0 72 = . 97 0 0 206 0 -. .. 41 0.. - 526 526 0 165 :.0 41.:. _ 0 ;` ,- " '526 47 0 .661 `. 0 880 0 ; 47f 1302 0 420 0 .. 788 0 :_ „..1220 0 IAF P .0 . _ F 6 c) AED excursion -22 �8 Envelope loss/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 p Subtotal pines 6 to 13) 643 298 5994 5112 Less extemal load 0 0 0 0 Less .transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal- 643 298 5994 5112 15 Duct loads 32% IM 204 145 32% 49% 1899 2490 Total roamload 846 443 177F 7892 7602 Air required (cfm) 42 201 390 338 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .A= -Fp- wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 ACCA .uick Calcs%Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Page 4 -- wrightsoft' Right-J® Worksheet Job: _ Entire House Date: QUICK CALLS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6769 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name FOYER M. BATH, ed wall 7.0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heattcool 4 Room dimensions 1.0 x 50.0 ft 7.0 x 8.0 ft 5 Room area 50.0 ft2 . 56.0 ft2 Ty Construction U-value Or HTM Area Load number (Btuh/ftk°F) (Btuh/ftz) or perimeter (ft) (Btuh) oorpedmeter. (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross WP/S Heat Cool 6 A 3A4oc6 0143 n.; 400 2;55 8 8 32 y:- 20 0 .. '0 - 0 0 4A5 tom ; : _; 0 7/0 n [ 21i56 19r31... , 0 0 0 0 ' . 0 : -'0 V)/ 13A-4ocs 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0 1A-clom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92. 11.31 21 21 229 238 0 0 0 0 W 1:.13A46cs 0:143 se 4.00 255 0 0 0 0 0 0. 0' . 0 t13AAocs 0.143 s 4.00 2.55 0 0 0 0 64 57 228 145 -G 1A-c1om 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241 1MAocs 0.143 w 4 00; 2 65 0 0 0 0 0 0 .0 0. 1A c1om ' 1270 w 35:56 55 21 '-0 . 0 0" 0 .''.0. 0 ;0 0 0770 0 0 0 : 0 = 0 0 0: P 12C-0sw 0.091. - 2.55 1.26 72 72 183 92 .- 01 0 0 0 C 16A 30mt1.= . • 0 032 .-- 090: %232 .. 50 ,; . 50 ;: , ..< .45 .: .. :118 56 : • . 56 : 50 ... •:130 F 22A-tpl 0.9t39 - 27.69 0.00 50 7 194 0 ,:: 56 8 222 0 1. 61 c)AED excursion _q9 Envelope loss/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 01 0 Subtotal (lines 6 to 13) 913 529 885 . 516 Less extemal load 0 0 0 0 Less transfer 0. 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 15 Duct loads 32% 49% 289 258 32% 49% 280 251 Total room load 1202 787 1166 768 Air required (cfm) 59 351 Sal 34 Calculations approved byACCA to meet all requirements of Manual .J 8th Ed. -Fk wrightsoft• Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr 11 0 Page age 5 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N Duct S stem Summary Job: -�+ wrightsoft0 y - Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:.772-466-6799. Fax 772-466-6796 Emil: QUICKCALCS a(AOL.COM For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL External. static pressure Pressurelosses Available static pressure Supply! return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating. 0.50 in H2O 0 in H2O .0.50 in H2O 0.25 0/0.250 in H2O 0.285 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 iri H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 OxO VIFx 99.4 115.0 st1 BEDROOM h 4702 232 232 0.360 7.0 Ox0 VIFx 23.9 115.0 st9 BEDROOM -A h 3327 164 163 0.300 6.0 Ox 0 VIFx 131.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 OxO VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 Ox0 VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 ox0 VIFx 31.8. 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 OxO VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 OxO VIFx 23.3 115.0 st1 M. BATH -A h 768 58 34 0 0 Ox0 VIFx 0 0 WIG c 174 3 8 0.309 4.0 Ox 0 VIFx 27.0 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 721 672 : 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak'AVF 1043 1091 O285 1020 14.0 0 x 0 VinlFlx {J}} 9 wri htsoft, 9 2017-Apr-11 09:29:38 �CA " f Ri ht-Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...uick CaIcslDocuments\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) . Clg . (cfm) TEL (ft) Design FR Veloc (fpm). Diam (in) . H x W (in) Stud/Joist . Opening (in) Duct Mat Trunk rb1 NO 1160 1160 0 0 0 0 ox 0 VIFx -}r}} htsoft 9 wri ¢ ;38 Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29Page 2 %�+� ...uick CialcskDocuments\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N