Loading...
HomeMy WebLinkAboutNOA- -SKYLIGHT0 File Copy MIAM1-DiADE DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION MTAMI-DADS COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 NOTICE OF ACCEPTANCE (NOA) T (786) 315-2590 F (786) 315 2599 Sun-TekManuiacturing, Inc. 10303 General Drive. Orlando, FL 32824 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICMG Skylight System APPROVAL DOCUMENT: Drawing No. STI-00000290, titled "ICMG", sheet 1 & 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated August 07, 2007, with last revision "A" dated May 04, 2015, signed and sealed by James D. Wells, Jr., P.E., on May 04, 2015, bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and the expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series and the following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after 'the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA member preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 13-1010.09 and consists of this page 1, evidence submitted pages E-1, E-2, & E-3 as well as approval document mentioned above. The submitted. documentation was reviewed by Helmy A. Makar, P.E., M.S. NOA No. 15-0513.09 MIAMt•DADHCOUNTY Expiration Date: 10/10/2018 18 % Approval Date: 09/03/2015 a3�ZQ15 Pagel Sun-Tek Manufacturing, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 07-0425.05 A. DRAWINGS 1. Drawing No. STI-00000290-SHTIISHT2, titled "ICMG", sheet 1 & 2 of 2, prepared by Sun- Tek Manufacturing, Inc, dated, 06104107, with last revision dated 08107107, signed and sealed by James D. Wells, Jr., P. E. B. - TESTS (submitted under NOA # 02-0729.07) 1. Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per PA 203 and Uniform Static Air Pressure Test per PA 202 of Model ICMG 4949 Insulated 'Glass Skylight with Polycarbonate Inner Liner" prepared by National Certified Testing Laboratories, Report No. 210-2789-1, 2 & 3, dated 03118102, signed and sealed by B. Portnoy, PE. C. CALCULATIONS 1. Anchor Calculations for attachment of skylight to cubing and curbing to decking, dated 08113107, signed and sealed by James D. Wells, Jr., P.E. D. MATERIAL CERTIFICATIONS (submitted under NOA # 02-0729.07) 1. Die drawings No. STI-214 of Deco Ring, prepared by Sun-Tek Manufacturing, Inc. on 6119195. 2. Die drawing No. STI-205 of Curb Frame prepared by Sun-Tek Manufacturing, Inc. on 12126196. E. STATEMENTS (submitted under NOA # 02-0729.07) 1. Code compliance and No -Interest letter issued by Product Technology Corporation on 08127102, signed and sealed by R. J. Quiroga PE. F. OTHER . 1. NO.4 renewal request letter issued by Sun-Tek Manufacturing, Inc., dated 08116107, signed by James Feudner. 2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 11-0601.03 A. DRAWINGS 1. Drawing No. STI-00000290-SHTIISHT2, titled "ICMG", sheet 1 & 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated August 07, 2007, with last revision "A" dated October 14, 2011, signed and sealed by James D. Wells, Jr., P.E. Imy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 15-0513.09 Expiration Date: 10/10/2018 Approval Date: 09/03/2015 E-1 Sun-Tek Manufacturing, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS 1. Test Addendum for Test Report NCTL 210-2760-1, prepared by national Certified Testing Laboratories, dated October 17, 2011, certifying the interlayer thickness, signed by Mark Bennett, Manager of Testing Services (see NOA#11-0601.02). C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami Dade County Department of Permitting, Environment, and Regulatory Affairs (PERA). E. MATERIAL. CERTIFICATIONS 1. None. 3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 12-1011.16 A. DRAWINGS 1. Drawing No. STI-00000290, titled. "ICMG ", sheet 1 & 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated August 07, 2007, with last revision "A" dated May 03, 2012, signed and sealed by Tames D. Wells, Jr., P.E. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. OTHERS 1. A compliance letter, prepared by J & L Wells Consulting LLC, dated April 25, 2012, certifying compliance with FBC 2010 edition, sign and sealed by James D. Wells, Jr., P.E. 2. Verification' testing to be performed per letter from National Certified Testing Laboratories, dated September 18, 2012, signed by Christopher Bennett. elmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 15-0513.09 Expiration 'Date: 10/10/2018 Approval Date: 09/03/2015 E-2 Sun-Tek Manufacturing, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 4. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL 913-1010.09 A. DRAWINGS 1. Drawing No. STI-00000290, titled "ICMG'; sheet I & 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated August 07, 2007, with last revision "A" dated May 03, 2012, signed and sealed by James D. Wells, Jr., P.E. B. TESTS 1. Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per PA 203 and Uniform Static Air Pressure Test per PA 202 of "Model ICMG 4949 Insulated Glass Skylight with Polycarbonate Inner Liner" prepared by National Certified Testing Laboratories, Report No. 210-3915-02, dated 09113113, signed and sealed by Gerard J. Ferrara, P.E., .on 09124113. 2. Revised Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per PA 203 and Uniform Static Air Pressure Test per PA 202 of "Model ICMG 4949 Insulated Glass Skylight with Polycarbonate Inner Liner" prepared by National Certified Testing Laboratories, Report No. 210-3915-02, dated 09113113, revised ' on 02126114, signed and sealed by Gerard J. Ferrara, P.E., on 02128114. C. CALCULATIONS 1. Anchor Calculations for attachment of skylight to cubing and curbing to decking, dated 10103113, signed and sealed by James D. Wells, Jr., P.E., on 10103113. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. 5. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. STI-00000290, titled `ICMG", sheet 1 & 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated August 07, 2007, with last revision "A" dated May 04, 2015, signed and sealed by James D. Wells, Jr., P.E., on May. 04, 2015. B. ' TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. elmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 15-0513.09 Expiration Date: 10/10/2018 Approval Date: 09/03/2015 E-3 DECO CUP 0.075 6083 T-6 ALUMINUM SILICONE TOP AND BOTTOM OFPOLYCARBONATE ( CONTINUOUS) STI-205 ( 0.06(r) MITERED AND WELDED CORNERS 2.45' WIDE x3.93' HIGH 6063 T-6ALUMNIUM 010 X 2-10 DECK SCREW 4" MINIMUM ROOF SURFACE TO LIP ROOFING FELT 17/32' OUTBOARD DSB GLASS BITE TEMPERED SWIGGLE INSULATED io GLASS SPACER (CONTINUOUS) 1 � (NSULATED AIRARGON GAS FIILLEDCE ARGON GAS FILLED NSULATED AIR CE T T INBOARb DSB STI.6 GLASS TEMPERED Zn EPDM GASKET �— CONTINUOUS WOOD LINERSTI401- 1.16" WIDE X 0.935 HIGH .177 POLYCARBONATE SHEET PALRAM PALSUN OR SHEFFIELD MAKROLON GP OR SABIC LEXAN 9034 LIGHT TUNNEL MATERIAL BY OTHERS (APPROVED BY DADE COUNTY) 12 X 1 12 CLOSED CELL PVC FOAM TAPE DESIGN PRESSURE RATING t80 PSF. LARGE MISSILE IMPACT RESISTANCE SHINGLES BUM (SEE NOTE 1) SEALANT (CONTINOUS) b/6" MIN. EMBEDMENT DWG. NO. STI-00000290-SHT1 SILICONE BEDDING (CONTINUOUS) STI.214 DECO RING 0.050 MITRED AND WRAP AROUND 6083 T-8 ALUMNIUM 1.65WDE X 1.18' HIGH #8-32 BOLT VW NUT (7) PER SIDE 0.125 X 2' 6063 T•6 ALUMINUM FLAT BAR CUT WITH WELDED CORNERS i 1/4' MAX. 012 X2" PHILLIPS PAN —HEAD SCREW (5) PER SIDE 1.11" MIN. EMBEDMENT 2X CURB HEIGHT TO BE SUFFICIENT TO MAINTAIN 4' MINIMUM LOWEST POINT OF FRAME TO ROOF SURFACE SUPPLIED BY OTHERS min 30" (APPROVED BY DADE COUNTY) FLASHING BY OTHERS IN ACCORDANCE WITH NRCA Engineer of Record `' NOTE: ' `J `• James D. Wells, Jr.,P.E. 4 min (1) ALL ROOFING DETAILS SHALL COMPLY WITH ROOF DECK Professional Engineer No. 53616 Protrusion CHAPTER 15 OF THE 2014 FLORIDA BUILDING CODE 4" MINIMUM DISTANCE FROM ANGLE LIP TO ROOF PRODUCTREVISED m 0Gn1$y(^B With lho Florid.WIdingCodo 5/6' MINIM(�N�{IINI/ (2) SURFACE IS FOR SHINGLE OR B.U.R. WITHOUT AcaPIMCONol�Na J&L Wells Consulting LLC INSULATION. FOR INSULATION AND TILE ROOF ADD�IO"Da° /8 1453 Arbitus Circle TILE HEIGHT AND INSULATION THICKNESS TO 4". ./�A_ o>� 0. 36' Oviedo, FI. 32765 (3) ANCHORS TO BE MADE FROM NON -CORROSIVE MATERIAL COMPATIBLE WITH ALUMINUM. '0 (407)496-5489 (4) NO ONE-THIRD INCREASE IN THE DESIGN PRESSURE WAS USED. Certificate of Authorization (5) TESTED TO TAS 201, TAS 202 AND TAS 203. g4�rNAL.11 No. 27162 ION: Q w- WAS 12" S REVISION: REVISE SHT. 2 OF 2 BSD DATE: 1B 07107 BY: 'RODUCTNAME: (CMG SUN-TEK MANUFACTURING, INC. DRAWN BY. JWF DATE: 05/03/201 DWG NO. STI-00000290-SHT1 REV. A 10303 GENERAL DRIVE ORLANDO, FL 32824 10 51.375 Max. 10.8437S 10,84376� 4.00 10.84375 10.84375 4•00 r 4.00 51.375 max ICMG 4949 #12 X 2 PHILLIPS P HD SCREW FASTENED SKYLIGHT TO CURB (5) PER SIDE I I #8-32 X 3A BOLT W/ NUT ATTACHES FRAME TO ALUMINUM BAR (7) PER SIDE DAYLIGHT OPENING 45.5" (MAX) X 45.5" (MAX) CURB TO DECK FASTENERS I #10 X 2.5" I 7.23 T.23 7.23 7.23 7.23 7.23 JA 4. 0 5.93 4.00 5.93 NOTE: 4.00 * (1) ALL ROOFING DETAILS SHALL COMPLY WITH CHAPTER 15 OF THE 2014 FLORIDA BUILDING CODE PRODUCC RGVISRD (2) 4" MINIMUM DISTANCE FROM ANGLE LIP TO ROOF as complying wish Ills Finridn SURFACE IS FOR SHINGLE OR B.U.R. WITHOUT Building Code Accepmnco NaV-qYINSULATION.FOR INSULATION AND TILE ROOF ADD Bxpi ion DateTILE HEIGHT AND INSULATION THICKNESS TO 4". (3) ANCHORS TO BE MADE FROM NON-CORROSIVEMATERIAIW toad COMPATIBLE WITH ALUMINUM. (4) NO ONE-THIRD INCREASE IN THE DESIGN PRESSURE WAS USED. DESIGN PRESSURE RATING 380 PSF. LARGE MISSILE IMPACT RESISTANCE i Engineer, of Record James D. Wells, Jr.,P.E. Professional Engineer No. 53616 J&L Wells Consulting LLC 1453 Arbitus Circle Oviedo, Fl. 32765 (407)496'-5489 Certificate of Authorization No. 27162.. L r )-SHT2 I SHEET 2 OF 2 SILICONE BEDDING (CONTINUOS) DECO CLIP 0.075 SILICONE TOP AND BOTTOM OF POLYCARBONATE (CONTINUOS) 98-32 x 9 bon W/ nut m per side 0.125X 2' ALUMNIUM FLNnBAR�6063 T� BUTT WELDED STI'205 (0.060') MITERED AND WELDED CORNERS #12 X2' PHILLIPS PAN HEADSCREW �_ FLASHING BY OTHERS IN ACCORDANCE WITH NRCA� I #1OX2-112'DECKSCREW 4" min (8) PER SIDE roof surface to lip ROOFING FELT— SHINGLES(l) ROOF DECK 5/8' MINIMUM BUTYL SEALANT DWG. NO. STI-00000290-SHT2 — DECO RING 0.050 6083 T-6 ALUMNIUM MITERED AND WRAPAROUND OUTBOARD GLASS DSB TEMPERED (liar) ARGON mAIR SPACE . PRGON GA9 Rllm ST16 GLASS INBOAR. TEMPERED(1/8') WOOD LINER 1, .777 POLYCARBONATESiEEr PALRAM PALSIN OR SHEPflELD MAIROLON OPOR SABOLEXAN9M4 1/2 x 1 112 closed cell PVC lea" topo LIGHT TUNNEL MATERIAL BYOTHERS (APPROVED BY DACE COUNTY) 2X CURB HEIGHT TO BE SUFFICIENT TO MAINTAIN 4' MINIMUM CLEARANCE BETWEEN ROOF SURFACE AND LOWEST LIP OF FRAME CURB SUPPLIED BY OTHERS (APPROVED BY DADE COUNTY) min n fmcinn FASTENER SCHEDULE SKYLIGHT TO CURB #12 X 2" PHILLIPS PAN HEAD SCREWS FASTENER SCHEDULE CURB ATO DECK #10 X 2-1/2" DECK SCREWS FASTENER SCHEDULE SUB -FRAME TO FRAME #8-32 BOLT w/ NUT TIPTO TIP MODEL PER LONG SIDE PER SHORT SIDE PER LONG SIDE PER SHORT SIDE LONG SIDE PER SHORT SIDE 51.375 x 5-1—.3-79 4949 5 5 8 8 7 7 48.375 x 48.375 4646 5 5 8 8 7 7 35.375 x 51.375 3349 5 4 8 B 7 5 J 35.375 x 35.375 3333 4 4 6 6 5 5 48.375 3046 5 4 8 5 7 5 32.375 3030 4 4 5 5 5 5 51.375 2549 5 3 8 5 7 4 35.375 M 2533 4 3 6 5 5 4 7.3752525 3 3 5 5 4 4 48.375 2246 5 3 8 3 7 4 32.375 2230 4 3 5 3 5 4 24.375 x 24.375 2222 3 3 3 3 4 4 19.376 x 61.375 1749 5 3 8 3 7 3 19.375 x 35.375 1733 4 3 6 ' 3 5 3 16.375 x 48.375 1446 5 2 8 3 7 3 16.375 x 32.375 1 1430 4 2 5 1 3 5 3 REVISION: REvlsloN: PRODUCT NAME: ICMG SUN-TEK MANUFACTURING, INC. BY: DATE BY: DATE: DRAWN BY: JWF I DATE: 08/05/20111 DWG NO. STI-00000290-SHT2 REV. A 10303 GENERAL DRIVE ORLANDO, FL 32824