i� -�wrightsoft 317 ST. LUCIE LN., FT. PIERCE, FL Project Summary Date Entire House By: QUICK CALCS, INC. 4946 Phone: 772d66-6799 Fax 772-46"796. Emall: QUICKCALC5@AOL.COM: For: THE GRAND-CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design .Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside.db - 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (0 cfm): 0 Btuh Central vent (0 cfm) 0 Btuh e) Hum(none). idification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 24753 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh Heatingg Cooling Vat (none). Area (ft2) Equipment'latent load 5521 Btuh Volume (W) 12511 12511 Air changeslhour 0.45 0.23 Equipment total load .30274 Btuh Equiv. AVF (cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 Cond' 25HBC536A*030- AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling. 24360 Btuh Heating output 34600 . Btuh @ 47*F Latent cooling 10440 Btuh Temperature rise 27 . OF Total cooling 34800 Btuh Actual'airflow. 1160 cfm Actual -airflow 1160. cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.5.0 in H2O Static pressure 0.50, in H2O Space thermostat . Load sensible heat ratio 0.83 Capacity balance point = 32 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - - wrightsoA, 2017-Apr-11 09:29:38 Right -Suite® Universal 201717.0.14 R$U08101 Page 1 ..uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N - wrightsoft° Right4@ Worksheet Job: Entire House Dace: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS ,AOL.COM 1 Room name Entire. House BEDROOM 2 Exposed wall 156.2 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cool 4 5 Room dimensions Room area 1445.5 ft2 1.0 x 297.0 ft 297.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) number (Btuh/f?;- F) (Btuh/ftl) or perimeter (ft) (Btuh). or perimeter (ft) (Btuh) . Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A flocs; ' 0143 [ ri -4:00 22 69 503 465 : _ 1862 >' . 1184 • , 72 72 '286 183 44&2om"- ' .. 13A4ocs 0 770 0.143 , n a 21:56 4.00 .19.31 2.55 ;_ 38 128 0 83 , 815 333 730 212 .: 0 0 0 0 .:, .', 0 0 .0 0 11 1A-c1om 11D0 1.270 0.390 a a 35.56 10.92 87..29 11.31 24 21 2 21 848 229 2082 238 0 0 0 0 0 0 0 0 W : ' W Y-C '13A4ocs 13A4ocs 0:143 0.143 se s 4.00 4.00 2.55 2.55 34 360 34 353 136 1414 86 899 0 216 0 216 -0 865 0 550 IA-c1om 13A flocs 1A,c1om .', 4A5 tom 12C-0sw 16A-30md - - 1.270 0.143 -1.270 0.770 0.091 0.032 s w , ,w w - - - 35.56 4:00 36:56 21.56 2.55 0 90 34.77 255 0.21 19;31 _ 1.28 .. 2.32 7 310 32'" 41 192 1446 7 237 2 . 41 192 : 1446 247 949 - 1140 880 489 1298 241 603 4776 ... 788 246 `:. '3354 0 104 32 ::: 0 _ 0 297 0 72 •. 2 - 0 0 `., 297 0 288 1140 , • 0 0. ;....: 266 0 183' 1770. .: .0 0 :• 689 P G . . ;; F 22A tpl 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c)AED excursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 2000 0 Subtotal (lines 6 to 13) 17848 17520 5053 4925 Less extemal load 0 0 0 0 Less :transfer 0 0 0 0 Redistribution 0 0 0 0 14 • Subtotal 17848 17520 5053 4925 15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400 Total room load 23503, 26056 6653 7325 Air required (cfm) 1 1 1160 1160 328 326 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. P.. wrightsoft' 2017-Apr-11 09:29:38 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N - wrighisoft- Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC KITCHEN 0 ft Oft 3 Rm height ei9 t 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 6.0 x 9.0 ft 1.0 x 172.0 ft 5 Room area 54.0 f12 172.0 ftz Ty Construction U-value Or HTM Area (ft t) Load Area (ft Load number (Btuh/ft2-°F). (Stuh/ft2 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross MRS Heat Cool Gross WP/S Heat Cool 6 13A46cs" : 0143 ri.:. 4;0 2.55 0 0 p .: :.0 , 0, " 0 0 0 '4A5-2din : ' 0 770 n' 21:56 19;31 0 0 0 0 0 ' 0 . .0 0 Vl/ 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 L-_Gp 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W .13A-4ocs 0.143 se. 4.00 2.'55 0 0 0 0 0 0 0 0 VN 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 1A-c1om 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 -G W 13A46cs. _ 0.143 •: w 4.'00 2.55 0. 0 0 .0 0 01 :0 0 1A-c1orn 1270 w 35.56 •. 55.21 : 0 0 0 0 0 0 0: -0 �-G ' G 4A5.2om ". 0.770 .w 21.56 19:31 0, 0 0 .0 0 0.1 0 0 P 12C-0sw 0.091 - 2.55. 1.28 0 0 0 0 64 64 163 82 C : ,: ,16A-30md' • A032 ,"= - 0.90 ':-" 2;32 `• . 54 54 48. '125 ; . .172 172 .:. •". " 154 ,399 F 22A-tpl 0.989 - 27.69 0.00 54 0 0 0 172 0 0 0 6 c)AED excursion -9 -170 Envelope loss/gain 48 117 317 311 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal (lines 6 to 13) 48 117 317 2311 Less extemal load 0' 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 117 317 2311 15 Duct loads 32% 49% 15 57 32% 49% 100 1126 Total room load 64 174 T 418 3437 Air required (cfm) 3 8 ' 21 153 Calculations approved byACCA to meet all requirements of Manual J.8th Ed. -Fk wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29: 2 ...uick Calcs%Documents\THE GRAND CARLTON-1446.rup Cale = MJB Front Door faces: N Page As- Job: wrightsoft° Right-M Worksheet at d Entire House Date: QUICK CALCS, INC. By 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL:COM - 1 Room name BATH BEDROOM 2 2 Exposed wall 5.0 ft 34.2 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 9.0 x 5.0 ft 1.0 x 203.5 ft 5 Room area 45.0 ft2 203.5 ft2 Ty Construction U-value Or HTM Area (ft Load Area Lo number (Btuhfft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 y! 13A floc§ , 0143 n;' 4:00 2 SS .40 40 160 : 102 ' 128 '> >:128 513 326 tom. : ' .0 770 - 'ri 2156 19.31 0 0 . 0 0 0 0 13A4ocs 0.143 a 4.00 2.55 0 b 0 0 80 56 225 143 1Aclom 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 : se 4.00 155 0 0 0 0 34 34 136 86 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 32 32 128 81 1A-c1om 1.270. s 35.56 34.77 0 0 0 0 0 0 0 0 13A4ocs 0143 w 4.00 2.55 0` 0 0 .0 0 0. .0 0 1A clom 1 270 w 35:56 55:21 .0 0 D 0 0: 0. 0: 0 4A5 tom •, .0 770 :w 21:56 19.31 - 0 0 0 0 0 "- 0 . 0 ;. 0 P - 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 0 . 0 0 0 G 16A=30md- : - 0.032 - - °0.90 2;32 .. .. 45 45 - 40 : 104 '_ . 204, 204 :: :.182 = 472 F 22A tpl 0.989 - 27.69 0.06 45 5 138 0 204 34 946 0 6 c)AED erxursion -16 -85 Envelope loss/gain 339 190 2978 3106 12 a) Infiltration . 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 425 214 3571 3498 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 15 Duct loads 32% 49% 135 104 32% 49%1 1131 Total room load 560 318 4702 Q Air required (cfm) 28 14 232 rACCA to meet all requirements of. Manual J.8th Ed. �A ' wrightsoft' Right -Suite® Universal 2017 17.0.14 RSUD8101 ...ulck CalesIDocuments\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: 2017-Apr-11 09:29:38 Page 3 -- wrightsoft° RightJO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 E)posed wall 6.0 ft 47.0 ft 3 Room height 8.0 ft heat/cool 9.8 ft heaticool 4 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 ft2 1.0 x 526.0 ft 526.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 y/ I--G 13k4=, "; `4AS2om . - 13A-tots :.0143 0 770 0.143 -n' . ri - a _ 4 00 24:56 4.00 :65 .. 19:31 2.55 . 0 0 0 0 0 0 0 .: 0 0 .. '. 0 0 0 ;. 255 38 0 :: 217 0 ."869 0 . _ 552 730 0 1 1A-c1om 11130 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W W T-C '13A4ocs 13A-4ocs 0.143 0.143 se s 4.00 4.00 255 2.55 0 48 0 48 0 192 0 122 0 0 0 0 0 0 0 0 1Ac1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 i2i13A4ocs• 0 143 - w 4.'00 255 0 0 0 0 206 ' ' 165 . 661 420 1A�c1om; . 4A5;2om 12C-0sw 1 270 0.776 0.091 ; w., w ' - 35:56 . 21.56 2.55 55.21 ` 19:31 1.28 0 0 56 0 0.: 56 0. .0 143 0 . 0 72 0 -. - 41 0 0 41 0 0 880 0 0 ,.. '788' 0 P G ., .: s16A30md.. -'0.032 - 0.90 232 : • '42 .. 42 , 36 ? 97 -526 ,' `526 ; 471 ..: :;,1220 F -22A tpl 0.989 - 27.69 0.00 42 6 166 0 526 47 1302 0 6 c)AED excursion -22 668 Envelope loss/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 643 298 5994 5112 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 643 298 5994 5112 15 Duct loads 32% 49%1 204 145 32% 49% 1899 2490 Total room load 846 443 7892 7602 Air required (cfm) 42 20 390 338 � A -�- wrightsoft' Rlght-Suite® Universal 2017 17.0.14 RSU08101 uick Calcs\Documents\THE GRAND CARLTON 1446.rup Calc = MJ8 Front Door faces: 2017-Apr-11 09:29:38 Page 4 - wrightsoft' Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-166-6796 Email: QUICKCALCS ,AOL.COM 1 Room name FOYER M. BATH 2 Egmed wall 7.0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 50.0 ft 7.0 x 8.0 ft 5 Room area 50.0 ft2 56.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2L°F) (Btu ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 AM40cs: •: 0143 -;n. :,too 2i55 8 - 8 32 _.- 20 ; 0 -.0 0 4A5 2,orir.,.. .0.770 : n . . 21:56 19:31 -''0 . • ..0 Q .. '0 0 : ,0 •' . 0 : 0: 13AAocs 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0 1A-c1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11130 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W 13A4ocs 0:143 se 4.00 2.55 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 64 57 228 145 L-G 1Aclom 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241 13AAocs 0143 w 4.00 2:55 ' 0 0 0 .0 0 0 0 0 1Ao1om 1.270 . w 35.56 5521 : 0 : 0 0 • 0 - 0 0 . •;0 0 4A5-2om. "0.770 :.w .. � 21:56 19 31 ; 0 '. 0 : 0 ' : • = 0 : 0- ' . 0 0 ; = 0. P 12C-0sw 6.091. - 2.55 1.28 72 72 183 92 0 0 0 . 0 C .. ; :16A=30Md - 0.032 ..' - . 90 2,32 . 50 50 45 ' '116 -56 < - 56 : . 50 _ . ,:130 F . 22A-tpl 0.989 - 27.69 0.00 50 7 194 0 56 8 _ , 222 0 6 c)AED excursion -39 -38 Envelope loss/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 913 529 885 . 516 Less extemal load 0 0 0 0 Less transfer 0 . 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 895 516 15 Duct loads 32% 49% 289 258 32% 49% 280 251 Total roam load 1202 787 1166 1 768 Air required (cfm) 59 35 W :4 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Fa - wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 5 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N - - wrightsofte Duct System Summary pat Entire House By: QUICK CALCS,INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:.772-466-6799: Fax 772-466-6796 Email:_ QUICKCALCS@}10L.COM ?roject Intormation For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 Ox 0 VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 Ox0 VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 Ox0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox 0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 Ox0 VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 Ox 0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 Ox 0 VIFx 23.3 115.0 st1 M. BATH -A h 768 58 34 0 0 Ox0 VIFx 0 0 wic c 174 3 8 0.309 4.0 Ox 0 VIFx 27.0 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx .� wiri htsoft° 2017-Apr-1109:29:38 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ..uick Calcs\Documents\THE GRAND CARLTONA446.rup Calc = MJB Front Door faces: N s Return Branch Detail Table • Name Grille Size (in) Htg (cfm) ' Clg (cfm) TEL (ft) Design FR Veloc (fpm). Diam (in) . H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 0x0 1160 1160 0 0 0 0 ox 0 VIFx t htSOft' 2017-Apr-1109:29:38 WCI 9 Right -Suite® Universal 2017 17.0.14 RSU08101 . Page 2 ACM ..uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N