HomeMy WebLinkAboutBUILDING PLANGulf Coast Supply and MFG 5v Crimp Metal roofing FL 411661.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min_ 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6° o.c. at all laps and two staggered rows 12" o.c. in field. Attach
12"
12'
.H.
.H.
5/8" thick light textured
stucco on typical concrete
block construction
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
01
Finish Columns with 5/8" thick x 8"W cut
5/8" thick cut coral coral finished stucco bands
finished stucco bands (� ELF-\//4TION SCALE: 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and C end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet \
12
SLOPE
12"
3
5/8" thick light textured
stucco on typical concrete
block construction
'-0" = Finished Floor - -------- - - - - - - - - - - - - - - - - - - - - - - - - - - -
LEFT ELEVATION
ELEVATION NOTES:
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps Fastened with corrosion resistant tin caps and with 1.25" ring shank nails
Spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
Z.)/ U 6111u>t u.uu u.vl 01 5LUCCO On Lypical conCreLe
finished stucco bands block construction
REAR ELEVATION
- Overhangs at 1'-O" unless otherwise noted on Roof law
- Roof pitch at 4:12 unless otherwise noted
- Any changes to this plan shall be submitted to the architect
for approval in writing prior to starting construction.
- Return ALL Stucco Bands into Window or Door.
5/8" thick x 8% cut-,
coral finished stucco bands
Product Approval Subraittal Affidavit
Opening Schedule Swing Doors, Overhead Doors, Sliding Doors, Windows & Skylights
Opening
Type
NOA/FL
NUMBER
Product
Model #
Manufacturer
Glass
Attachment method
Expiration
Date
Design Pressure
of Approved Tests
1,2,3
414
FL# I�i499.2
Single Hung
Series 185
MI Windows
and doors
6 x tlpcons w mi prig ation at max.
rom each corner and L o.c. thereafter through Pf Buck Into solid
?filed CMU wall maintaining min 2.5" edge distance in strict adherence
to the product approval.
+ 60 psf
-
16-0330.02
Overhead
Garage Door
Model 824/811
9'-4' max. width
1G -O" max height
DAB
uta x I.' 5TF1 5=k to concrete block with i filled ce mt
0 $5 bar vert. using 3/8' x L' Hiltr HLC Sleeve anchors at e' o.c.
th 1.25" dia. washers with min. 4' edge distance. Install track to buck
g
ng iD 5/IL" x 15/8' full thread lag screws m each bracket maintaining
min. or 1.5' edge distance - GC to stmctlg adhere to product approval
rovide 1/1L' ushnut washer on railer &harts.
10-9-21
+ 50.0/-60.0 sf
p
B
FLU 166-14.1
Fiberglass
Desi nPro/
Smooth Pro
Jeld-Wen
_lco I/4" dia. tapcon with min 1.25" embedment at 3" max
'rom corners and 11.5" o.c. max thereafter in head and jambs.
+ 50.0 PSF
C
FLU 15332.2
Sliding Glass
Door
Series 420
Mi WindOWS
and doors
L Ia. x �cona w min. Penetration at g max.
rom each corner and I� o.c. all double row thereafter throu h
PT Buck into solid filled CMU wall maintaining min 2.5' edge distance
n strict adherence to the product approval.
± 48.2 PSF
Product
NOA/FL
NUMBER
Model #
Manufacturer
Attachment Method
Ex ppiration
Date
Design Pressure
of Approved Tests
Mullions
FLU 15353.8
CM-18531
vertical mullion
MI Windows
and doors
For CMU use (2) 1/4" x 2 3/4" tapcon& with min 1 1/4" embedment
penetration into each Mull Clip. Attach with
to clip using (4) #10 x 1.25"
self tapping screws per clip as shown in product approval.
+ 118.9 PSF
_
Roof
FLU 11651.12
5V Crimp
Metal RoofingGulf
Coast Supply
and manufacturing
24 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lbfelt underlayment Installed with min. 4' side laps and 4" end
laps fastened uith corrosion resistant tin caps and with 1.25" ring shank nails
%paced L" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detall on roof plan
- 108.5 PSF
Siding
Stucco on Block
Soffit
F L # 121981.3
Model T4 12" vented
Vinyl Soffit
Kaycan
Install using 2" x 2" battens at 6" o.c. screwed to soffit framing using
48 x 3" wood screws at each truss. Install soffit to battens using
0.12"dia. x 1.5" Iona rina sank nails with /8" dia. head.
+55.0/-35.0 PSF
Hurricane
Panels
FI# 150%.2
24 Gauge
Storm Panels
Global Protection
Products LLC
Install using 1/2" dia. solid set lead anchors with 1/4" dia.-20 x 1.5"
long SS screw head combo. with Neoprene washer at 12 1/2" o.c.
along the bottom and 13" o.c. at the top
+ 45.0 PSF
-
I have reviewed the above and approved it
by my seal below. ( Architect or Engineer of Record
SCALE: 1/4" = 1'-0"
Interior Non-Bearin
2"
OEM
5/8" thick x 8"w cut
coral finished stucco bands
Garage Finished
-0'-4" A.F.F.
truss bottom cord
e
_. _srmesh OR
Cx6" 410/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
Fartitlon
nts
SCALE: 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tm caps and with 1.25" ring shank nails
spaced C o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detall on this sheet
SCANNI
BY
ST LUCF- Imo'
12
-4 1 SLOPE
Iiiiiiiii-ess-
1
n7I-ml
ro I
71mill
5/8" thick light textured
stucco on typical concrete
block construction
FRONT ELEVATION
/70r 01cy3
T, L1�tCrF' MtTN-rY FTTff nivC T11irTcTnv
"I","10 FOR C IA 'CE
KVIEU'LD s '
.AN ��'D tR-N T NTU5T RE PT ON JOB
IN() �r�l' C 10S� VILL BE MADE.
/8" thick x 8"w cut
)ral finished stucco bands
Aid. MANUPAMHtN LMU8 W40MNG
U FACTORS AND SW COM
WFSC ENERGY CUOE M E
ITH
REMAIN ON ALL DOORS AND
W
UNTIL INSPECTIONS ARE R
ApPp�
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REaU1RE0 BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
0"P6Y With AL* AppfrlCARLE CODES.
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OF RECORD
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using 8d nails. Substrate
to be 19/32" COX Plywood nailed at 6" o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
SCALE: 1/4" = 1'-0"
5/8" thick x 8% cut
coral finished stucco bands
Finish Columns with
5/8" thick cut coral
finished stucco bands
ALL CON7f2AC70R WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: Sth Edition and ASCE I-10 for Wind Loading
Building Design is: Enclosed Risk Categoryy: II Wind Velocity: 165 mph ultimate
Mean Roof Height- Il'-0" Roof Pitch: 4:12
Internal Pressure Coefficient: ± O.I8
Subjectabilitg to damage from: Weathering: Negligible Termites: Ver--4 Heav--4
Width of Roof End Zone: 3'-4" Wind Speed: 165 mph ultimate
Wind Exposure Classification: C
Adjustment factor for Exposure Height: 1.21 x 0.6 = 0.126 ASO design
Load Combination: ASCE 7-10 Section 2.4 OL+LL; DL+0.6WL; 0.6DL+0.6lOL
Components t Cladding Wind Pressure (NET) Roof Zone: I. +20.6/-32.6 psf
Roof Zone: 2. +20.6/-51.0 psf
Roof Zone: 3. +20.6/-84.0 psf
Components t Cladding Wall End Zone Width:-3'-4"
Components t Cladding Wind Pressure (NET) Wall Zone: 4. +35.8/-38.1 psf
Wall Zone: 5. +35.8/-41.8 psf
Components t Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3 psf
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided? -es
Are Components an Cladding Details Provided? Yes
Minimum Soil Bearing Pressure: 2,500 psi, Presumptive: X Bg Test: psi
This Building Shall Have the Following:
APPROVED SHUTTERS: X IMPACT GLASS: BOTH: NEITHER:
ROOF LIVE LOAD: 31 psf ROOF DEAD LOAD: 10 psf
FLOOR LiVE LOAD: --I-S psf FLOOR DEAD LOAD: 1O psf
JOB ADDRESS: 'j�j \� 1A Q L---,`-'K1zr�
= 2.12
rrru
= Roof Zone I
Walls Zone 4
Roof Zone 2
Walls Zone 5
END ZONE
Corner Zones
Roof Zone 3
FLOOR FL,4N
CRASH POST DETAIL
TYPICAL NOTES: SCALE 1/4" = 1'-0"
I. Contractor to verify ALL notes and dimensions prior to
36" high by 4" diameter
steel crash post. Floor
proceeding With work.
Flange with 4 - 3/8"
2. Contractor to STRICTLY enforce ALL OSHA Requirements.
expansion bolts into
slab (3/8"t 50 ksi steel plate)
3. ALL Lumber to be used as Beam, Rafters, etc... to have
a minimum 1,,400 P.S.I. fiber stress.
`"
4. No dissimilar metals to touch.
2!,2" 2'r"
S. ALL Concrete used for slabs shall be min. 2,500 PSI concrete.
ALL Concrete used for vertical filled cells, coat. tie beams etc.. to
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix
m
°
2i2'-
�. Drywall at ceilings shall be leveled and attached to bottom chord
of trusses with screws per FBC R702.3.5.
o 0
2�2
1. ALL wood in contact with concrete shall be pressure treated.
8. ALL wall dimensions are nominal and not finished wall or stud dimensions.
9- ALL plumbing fixtures to be low flow.
10. Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
11. Contractor to Provide a 2'-8" wide door at one bathroom for
2%"
2�,"
handicap accessibility requirements.
i2'
i2'
12. Lowest finished floor to be set by Governing Building Department
6„
surveyor to set in field.
13. Separation between residence and garage shall be per FBC R302.�
14. Door between garage and residence shall be 1-3/4"t 20 min. rated door
W.H. = Water Heater
15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 pper
FBC R302.9.1
lb. Wall and ceiling finishes shall have a smoke -developed index of not greater than '450
per FBC R302.9.2
11. All exposed attic insulation materials installed on attic floors shall have a critical radiant Masonry Beam
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
I" x C P.T. Buck nailed to
block with case hardened nails
materials exposed on the underside of the roof deck or on the attic walls shall comply
prior to door attachment
with F.B.C. R31� - see permit info box of code edition
:..... :.
18. Gypsum board material shall conform to ASTM C3�, C19, C47S, C514, C(30, C931
p 1
C 395 CI 39� be
C��O, C1002, C104�i,C11II, C1178, C1218, or and shall installed
according to the following: (FBC R702.3.5)
Drywall
Thickness
Location
Orientation
Framing
Member
Max.
of fasteners
spacing
Nail sizing options for
installation of drywall into
Spacing
Maximum
wood framing members
Nails
Screws
2" x min. thickness
13ga 1 3/8" long with 19/64" head
Ceiling
Perpendicular
24"
-1„
12"
OR
0.098" diameter x 1 1/4" long
annular -ringed or 5d cooler nail
�2
OR
0,080" dia. x 1 5/8" long witl,
Walls
Either
16"
8"
I6"
Direction
15/64" head
OR
Gypsum board nail 0.086" dia.
x 15/8" with 9/32" head.
13ga 1 5/8" bong with 19/64" head
Ceiling
Perpendicular
24"
-1"
12"
OR
0.098" diameter x 1 3/8" long
annular -ringed or bd cooler nail
6
OR
0.092" dia. x 1 1/8" long with
Walls
Either
16"
8"
16°
Direction
1/4" head
OR
- ypsum board nail 0.0915" dia.
x 1 -1/8" with 19/64" head.
Install SGD thru buck into
block with 3/16" tap -con with _s
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product abproval i i
1a..__.
19. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.(,
A108.1, A118.1, A118.3, A13�.1 and A131.1
20, Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
all
C1288, C1325, OR C1118 and insted i.A.W_ manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompaneyin smoke
developed index not to exceed 450 when tested in accordance wit> ASTM E 8�.
Insulation shall comply with F.B.C. R31�.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 wood-
5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced C o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet \
Simpson HETA 20 or equal
hurricane anchor at each truss 12
with (10) IOd x I 1/2" nails
( 24" o.c.) supporting Max. 4
18101bs. uplift i
Aluminum Drip -
Edge t Fascia
2" x 6" Sub -Fascia
Kaycan full o vent vingl soffit installed
using 1/8" dia shank x 1.5" long gals.
roofing nails with 3/8" dia. head per
product approval — see chart sheet #1
5/8" thick light textured
stucco on typical concrete
block construction
45 bar vert. w/
30" overlap —
at each filled cell
G,.a.
TYFICAL
Wood
Base
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
(shop drawings by manufacturer)
" \R-30 blown fiberglass
in bottom chord of trusses
I/2" drywall with smooth finish
Two rows of beam block filled with concrete
and (1) #5 bar cont. in each row. Substitute
precast lintel filled with concrete and (1) 45
bar Cont. For bottom row over openings
1/2" dr wall over i" x furring
strips at 16" o.c. with R4.1 fi-foil
insulation on typical 8" Block walls
All drywall to be installed per FBC R102.3.1
i and shall meet all pertaining ASTM codes.
ao Mortar to be Type "M" oney proportioned per FBC R607.1
and Mortar fonts shall comply with FBC R601.2.1.
Provide Our-O-Rock at all wet areas (ex. showers, tubs etc...)
Fill cell with concrete and
(I) 45 bar vert. (typical).
Max. spacing shall not exceed
48" unless otherwise noted
see foundation plan notes For
spacing at openings
4" concrete slab with fibermesh OR
6"x6" #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
_ T1—fT
� W � Ml
SECTION
14" MIM1111-
x 14" Concrete footing
with (2) #5 bars cont. and #5
transverse bars at 48" o.c.
Scale : 1/2" = 1'-0"
Ell
N_T.S.
Head
f ixed door
sliding door
AREA CALCULATIONS
Living A/C =
144L
sq.
ft.
Front Porch =
1-41
sq.
ft.
Rear Porch =
200
sq.
f t.
Garage =
321
sq.
ft.
Total Under roof=
2108
sq.
ft.
Total Cubic Ft =
II,5L8
2' VTR
JAL
I
I
I
21' VTR
Master
Bath I I 1
1 . I
La2v. I
2• 1
Lev. I
41 1 2" VTR
3C I JIL
i 1
2. 3.
shiur.
Kit. Sink 1
I
Kitchen 2 I
I
I
Lay.
3-
W.C.
Bath #2 shwr.
3" 2-
C.O. XTo Septic
PLUMBING RiSER
I" x 6" P.T. Buck nailed to
block with case hardened nails
prior to door attachment e
n Track Typical Flooring
Sill Install SGD thru buck into
block with 3/16" tap -con with
S l l d i n g D o o r D& t a l l I penetration at ." max.
fromom each corner and 20." o.c. max
At Masonry Wall
thereafter at jambs per product approval) a m b
NTS
el—
UU indoui
Schedule
1„iark
Size
Rough Open.
Window Description
PRESSURE ZONE
1,
4'-5%a"x 5'-3 %"
54%8"x 63%,"
Single Hung
ZONE 4
2.
C-2%"x 5'-3 %"
15" x 63 %4"
Single Hung
ZONE 4
3.
2'-2" x 3'-2 1/2"
21 Y2" x 38 %8"
Single Hung
ZONE 4
4.
4'-5%8"x 4'-2 %"
54%"x 541'l6"
Single Hung
ZONE 4
ALL
Windows to be aluminum
Windows w/ tint
and mullions per
elevations.
ALL
windows to withstand
pressures in permit info box on
sheet
ALL
windows in bathrooms to
be tempered
All
rough opening
dimensions
to be verified by contractor
with
manufacturer s specs prior to construction
[Door Schedule
Mark
Size
Rou h Opening
Door Description DDtion
PRESSURE ZONE
A
9'-Ol' X if-011
108" x 84"
Overhead Garage Door
ZONE 4
B
3'-0" X 6'-8"
41 %"x 83%"
Fiberglass Panel - Inswing
ZONE 4
C
6'-O" X 6'-8"
�4" x 81 %2" ;r° CCe bottom
Sliding Glass Door
ZONE 4
D
2'-O" X 6'-8"
Solid Core - Wood
- 6-Panel -Bi-Fold
Finished 24" x 81 %2"
E
2'-6" X 6'-8"
solid Core - Wood
- 6-Panel
F
5'-O" X 6'-8"
Solid Core - Wood
- 6-Panel - BI-Fold
G
2'-8" x 6'-8" x 1 %,"
Solid Core Wood, Steel, or Masonite Door
H
2'-8" X 6'-8"
solid Core - Wood
- 6-Panel
J
2'-6" X C-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
K
2'-8" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
ALL Exterior doors to withstand pressures Stated in permit info
box on sheet al
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED iN PERMIT INFO BOX ON SHEET 41
All rough opening dimensions to be verified by contractor
with manufacturer s specs prior to construction
14'-O"
12" 8'-6" ,12"
00
00
-
° °
EGRESS
12" x 12" concrete column block filled
with concrete and (2) #1 bars vert. tied
_
Into lintels above
0
Covered Porch
°
o
12'-8"
O
N
00 O O ° D D EE
°° © o
MASTER I
-
°'�
BEDROOM °
A.F.F.OD
i
v
~tA
8'-O" A.F.F. Vaulte Ceiling
Flat Ceiling
o
o
GREIAT
ROM
0
"
Rod 8 helf
> > < >°
° 1
I I �-
H
Vanity to be I 1 t I -v
N
34 %2'hI9 I N N
-Ln
o
CL O 1
0 2" x 6" knee -wall 8`-O" to 9'-8" A.F.F.
O below top VVI
rr r counter Vaulted Ceiling
1
Ji DiNiNG
cABINE Rod Shelf $„ �7S F\ I O
w
��' \'��
��
ATH `� I
-
O
W
°
° Vanity to be
34 %2 „ high
-
High Wall °
m KITC3'-81, I o
Vent,
Dryer
- w
through
wall
O L — _ I-I/2" -
I
8'-0" A.F.F. Uver-fian'g
— —kn\/
- Flat Ceiling ° °
d "
(j
o 101-51,
T_(_ �31
Upper cabinets to
extend over Ref. 3'-O"4" e'-1"
c"y
2" filler -,I
iv
I
i ef. R n ® BATH
�
anrng—
�et�
_ Rod t Shelf _O O
R—II Batts nsulatron W H " <~ ) N
O
O
/ C
in 1
# I
4"(P Steel Ballard
See detail on thi�sl�et ,
I �„ _ W
1 22" X S4" � I y I ``� O
_m
in
Provide auto I Attic Access O I
N
closer with light I O
---- d
q 22" _ _ 8'-O" A.F.F.
150 ,4m Flat Ceiling
P 4„
v,�
n�
-1
Meter
6'-0„ 11,_6„
Panel m
n
,
m
SECOND
,is
GARAGE E ERGEN BEDROOM BEDROOM -�
EGRESS
O S'-4" A.F.F. 0011 MT E)
O Flat Ceiling
0 0,
O
a
O
r-----------------1 EGRESS
Block wall in 0
`n
I garage to be I - E) (EC0�0
1 struck block i
O
I I O O
I I _ COVERED
12" x 12" concrete column block filled
PORCH with concrete and (2) Z bars vert. tie
o
O
into lintels above
Ln
i
I ® I
I I
O
O
00 DD 00 ° °
—
00
2,-81
4,_2„
Install windows thru buck into
block with 3/1C tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at jambs and 20" o.c. max.
Exterior face at head and sill per product approval
of wall —, / \ Buck to ke 1" x 4" PT
Detall at Windows
Braden t
Braden AiA, PA
Architects
— Planners
411
S.E. Coconut Avenue
Tel :
(112) 281-8258
Fax
: (112) 281-8283
E—mail:
bradenaia5comcast.net
Stuart, FL
34996 UAAC000032
I"x4" P.T. Buck nailed to
'block with case hardened nails
prior to window attachment
NTS
Attach buck to block wall with
1/4" dia. Elco cone screws with min.
1 1/4" penetration at 12" o.c. max
and 4" max from each corner thru
Exterior Face 2" x 6" PT Buck
of wall
Varies
iNSTALL VULKEM BLOCK SEALANT #8 Wood screws thru jamb into buck
ON ALL JAMB, HEADER, AND at each hinge and 15" o.c. max and
SILL BLOCK PRIOR TO BUCK D e t a i l at D oor prior to door attachment
INSTALLATION
NTS
W nne Building Corp.
GRAGE
The Grdnd Carlton LEFT
Spanish Lakes
St. Lucie County Florida
Date Drawn : Revisions Sheet Comm 4
5-9-1-1
Drawn by:
C.C.U. 2 12-2�
Checked by:
D-R-B- OF 5 We �_
STRUCTURAL MOTES:
I.
ALL FOOTING ARE DESIGNED FOR A MiNiMUM OF 2,500 PSF SOIL
q.
BEARING CAPACITY. iF ANY SUB -SOIL, MUCK OR NON -UNIFORM
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2-
ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS
10
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
BE 3000 PSI OR 4,000 PSi GROUT MIX AT 28 DAYS
3•
POISON SOiL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOiL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
II.
4
GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10
WELDED WiRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
12
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WERE MESH.
5•
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FiLL iS BROUGHT IN. FiLL TO BE SPREAD IN 12" LAYERS AND
MACHINE COMPACTED TO A MINIMUM OF 2500 PSi IN AREA OF
13.
BUILDING CONSTRUCTION
6
TEST FOR FILL COMPACTION MINIMUMS PRIOR TO FORMING SLAB.
14.
GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
15.
ATTENTION OF THE ARCHITECT.
16.
8-
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
I�.
FOUNDATION PLAN
SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
FROM HOUSE TO DRAINS (iF PROVIDED) PER PLANS
DESIGN LOADS ARE AS FOLLOWS:
ROOF (DL+LL) = 41 PSF
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET #1
EXPOSURE ="C"
ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A-16, t
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL.
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTING: 3"
BEAMS: 1-1/2"
LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1600 PSI
ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
1. Any changes to plans must be submitted to the architect SCALE: 114" = 1'-0"
for approval before proceeding wlth construction.
2. Contractor shall be responsible for Verification Of all Termite Protection for �GW
notation and dimensions before starting construction. Construction.
3. Soil conditions assumed to be 250C psf. Should any other conditions be
the architect shall be notified led In Writing for revision Soil treatment used For subterranean termite prevention
encountered, inside the foundation perimeter shall be done after all
,4. Verify all recess thickness at showers, tile, etc..., excavation, backfilling and compaction is complete.
S. Contractor to provide filled Cell with concrete and I US bar Vert. at -48" If soil area is disturbed after initial chemical soil treatment
O.C. max. Provide (1) filled cell on each side of openings up to S'-I1" Wide. area shall be re -treated With a chemical soil treatment
Provide (2) filled Cells On each Side Of openings from so'-6" to 9'-11" including spaces boxed or framed.
and Provide (3) filled cells on each side of openings from 10'-0" and up Treatment must be 1n accordance With the rules and laws
Contractor to See plans for any other condition used. Foundation walls established by the Florida Department of Agriculture and
Shall have filled Cells at 24 11o.c_ unless otherwise noted (See section) consumer services.
�. Contractor to provide for Form Board Survey - Form Board Survey Protective sleeves around metallic pipin penetrating
to be provided to Truss Company prior to truss construction concrete slab on grade floors shall not L of cellulose
I Contractor to provide for soil test prior to construction and provide containing materials and shall receive appllcatlon of
a Copy of soil test t0 architect for review prior to construction termieide in annular space between sleeve and pipe.
8_ ALL Reinforcing steel shall be grade �0, meeting ASTM A-16 and
A-3S specifications. ALL Anchors to be A-301 steel.
9. Provide a minimum of 3 concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
#5 bar vert. w/ 30" overlap SEE TYPICAL
at each filled cellSECTIONS
4" concrete slab with fibermesh OR
611x6" #10/10 WWM on 10 mil Visqueen over
clean compacted termite i reated fill
Grade
III IIII IIII: ::�',:� IIII IIIII�IIIII
� E _
ttl _
14"w x 14"d concrete monolithic
footing with (2) 45 bars cont.
3
14"
TYPICAL FOOTING DETAIL
J SCALE 1/2" = 1'-0"
4" concrete slab with f ibermesh OR
6"x6" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
#S bar cont
Stepper
o . foundation plan
•'d
1O„ (2) #5 bars cont. bottom steel
12"
DETAIL AT GARAGE STEPDOWN
SCALE 1/2" = 1'-0"
12" x 12" concrete column
block filled with concrete
and (2) #1 bars vert. tied
into lintels above Verifg house slab
height in field
Top of f ooter
16" below finished floor
"91
SCALE 1/2" = 1'-0"
Thicken edge to 8"x8"
with concrete and 4" concrete slab with fibermesh OR
one 45 bar continuous 6"x6" 910/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
GRADE
1
li li m
ll ;
f PORCH SLAB EDGE DETAIL
SCALE 1/2" = 1'-0"
#5 bar vert. w/
30" overlap
at each filled cell SEE TYPICAL
�SECTiONS
Adjust curb height
based on gar. floor 4" concrete slab with (ibermesh OR
SIDpe. 6 x6 1*10/10 WWM on 10 mil Visqueen over
bar in curb clean compacted termite treated fill
Grade
0a — —
IIII I I , 14"w x 14"d concrete monolithic
3 I Il
footing with (2) #S bars cont.
14"
�j GARAGE CURB DETAIL
SCALE 1/2" = 1'-0"
2" x 6"
PT wood secured
with \
3/8"dia.
x 6" anchor bolt
at 18" o.c.
overhead door track secured to
wood
jamb per manufacturer's product
approval
Garage
Door Jamb
Detail
GARAGE
DOOR TO WITHSTAND PRESSURES STATED
N T S
IN PERMIT
INFO BOX ON
SHEET #I. SEE PRODUCT
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
Filled Cell Masonry Column With One
45 From Footing To Tie Beam
Conc. Fill To Be 3000 PSi
See Floor Plan For Location
Single Pilled Cell Column
NTS
Filled Cell Masonry Column With One
45 From Footing To Beam Each.
Conc. Fill To Be 3000 PSi
See Floor Plan For Location
Double Filled Cell Column
NTS
Braden it Braden AiA, PA
Architects - Planners
411 S.E. Coconut Avenue
Tel : (112) 281-8258
Fax : (112) 281-8283
F : E-mail: bradenaia8comcast.net
Stuart, FL 34996 UAAC000032
I
u
141-01,
2 1 IIJIUI _i_i_'_i_ILi_�_�_� Il°JIUI I !�
-----6� ----�
I 24
fry_'
I
N
I Thicken footing to
24"w x A"d x 24"L
FI 1 under filled cell
1 under girder bearing.
34'-O"
r• •
e �
�J)-------L__� --F --- °
I J
Filled cell under
girder above
Rear Patio/Slab r
to be poured separate F4
from the house slab.
m
k
L--- —--———— — — — — —-
FI 1
Rear Patio/Slab to
be flush with bottom of °
sliding door recess. I _
Slope 1/2" 1
F-
F-
I
IF-
F-
I'-
I I�
1 FI
I�
32'-8"
H.B. 1
4" concrete slab with fiber esh OR
O o 6"x6" 910/10 WWM on 6 mil V squeen over
1 clean compacted termite tr ated fill
�I
i
01
Fi I0 0
°
O
a 0 0
A/C -
$$ I I 4"0 Steel Ballard
L filled w/ Concrete 0 �— W
FS
of �O� I I 1=01
O� Id
L_-�
E,nq
Q)}�
E
I
�
u
.33 �
v
I
0CA
\
\ FI I
oo"rr F51
_ �-------Jo
T- T-
O O I I ! I I O 00
X O
— Recess for — — V —
nn Garage Door -7
3is" 1 91-01l
3'-51,
o
F4 — F4
F F
2 6 _'I ll'-6" 6'
12" x 12" concrete column block filled
with concrete and (2) #i bars vert. ti
into lintels above
FOOTiNG
SCHEDULE
Mark
Size
Description
FI
14"W
x 14"D
MONOLITHIC FOOTING
WITH 2 #S BARS CONTINUOUS
F
12"W
X 12"D
MONOLITHIC FOOTING
WITH (2) 45 BARS CONTINUOUS
30"
x 30" x 16"p
COLUMN FOOTING WITH (4) #5 BARS EACH WAY
8"W
x 8"D
THICKEN SLAB EDGE
WiTH I #S BAR CONTINUOUS
FS
14"W
With
x 14"D
Curb at Garage
MONOLITHIC FOOTING
WITH 2 #S BARS CONTINUOUS - CURB 8 0'-0"
ROOF SHEETING
ATTACHMENT DETAIL
I. Minimum Nail Size = 8d ring shank (min. 2.5" long)
2. Minimum Screw Size = U8 x 2"
3. Minimum Sheathing Thickness I9/32" CDX PI wood
4. Use nails or screws based on pressure for root' stated
in permit info box on these plans for zone 3
Ke
Area
Edge
Field
Fastener
Pressure
Zone I
C
6"
8d ring shank
45 psf
Zone 2
.4"
C
8d ring shank
% psf
Zone 3
.4"
.4"
8d ring shank
84 psf
** Zone 3a
�"
I 6"
148 wood screw
112.5 psf
** Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Verify with Plan
Concrete
/Lintel
Column
V+ 1
Rebar
to Lintel
12"x 12"
Column Block
--,41
Rebar
Provide #5 bars with min. 48 bar Provide 45 bar set in pre -cast
diameters overlap Into beam. Tie lintel Into beam where length of
filled cell steel into continuous g
beam block steel. the opening calls for it.
Provide Cast -Crete
BUB-OB/OT precast
lintel set in mortar r '
Min. 8" Bearing - - - -
•-.�.�j• -;fit. ''�,,
4..:41
1,
CBS WALL
Provide PT Buck ':1 Poured Filled Cell
attached per ,iamb I:j, a
details into filled cell
4" Pre -cast
Provide 45 bars with min. 48 bar
1 diameters overlap in filled cell. Tie
filled cell steel Into continuous
footer steel.
Scale: 1/2" = 1'-0"
SINGLE PLY REAR GIRDER TRUSS
Nail 2" x 4" blocking to vent. leg of
truss with IOd x 1.5" nails at 4" o.c.
Install Simpson MGT into wall using
5/8" dia. threaded rod set min. 12"
into wet beam and (22) IOd nails into truss
48 Bar Did.
Min. Overlap TRUSS BLOCKING DETAIL
AT GIRDER STRAPPING
4tta m n t AT CENTER
BEARING POiNT
NTS
1/8" thick light textured stucco installed per
T
B EA �1
SCHEDULE
ASTM C 926 over AS 1 M D type 2 paper backed
wire lath nailed to substrate through one layer of
ASTM D Type 2 felt paper using 8d nails. Substrate
to be 19/32' CDX Plywood nailed at L" o.c. in field
and edges with IOd ring shank nails into studs.
Mark
Size and
Description
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #1101.12
2L dqa. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
woo screws wtth self sealing washer at 12 o.c. max spacing over ASTM D
F „
(type 2) 30 Ib felt underlayment installed with min. 4 side laps and 6 end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6 o.c. at all laps and two staggered rows 12" o.c. In field. Attach
deck to trusses using attachment detail on this sheet
BI
Two rows of beam block filled with concrete and 1 45 bar
continuous in each row. Hook vert. bar over top bar with
#5 90° bend bar with a 10" min. la at to bar.
P P
Additional Precast Lintel
#5 bars
' CLEAR
Lintel
Length
Bar
Length
Clear
Span
n "
AB
Bars
11ii
Bars
2,=3
;•;'.
i ► t t r `: r
2'-10"
2'-8"
i'-L"
none
3'-C
31_411
2'-2"
2,93
none
eFe-OBAT 8F8-IB/IT 8F8-IB/2T
Additional
4'-0"
3'-10"
2'-8"
2,43
none
- #5 bars
CLEA ".'.!r`
4'-L"
'�'-4"
3'-2"
2,1t3
none
- One Row of "H"
5'-2"
4'-0
2,43
none
=t Block Above
`
2,U4
none
r .l Precast Lintel
6'-4"
5'-4"
2,U4
none
? t Additional i
#5 bars ----�'
7'-L"
-1'-0"
6'-2"
2,#5
none
BFIL-IBAT BFIL-IB/2T
8'-4"
T-10"
T-O"
2,U5
none
NOTES:
ALL reinforcing steel is grade LO.
I. min. coverage of steel=1.5"
2. min. bearing required a ea. end=8"
3. standard for remf, steel=ASTM ALiS
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
r01
LINTEL SCHEDULE
Mark
Window
or 0oo
Unit
Width
Lintel
Size
Cast -Crete
Specification
Rows of
"H" Block
Above
��
Bottom
Steel
size
Top
Steel
Size
Max
Gravity
Load
(PLF)
Max.
Uplift
Load
(PLF)
Max.
Lateral
Load
(PLF)
L22
2'-2"
3'-L"
eFe-OBAT
I
#5
3001
1569
1024
1_31
2'-4"
2'-8"
V-1"
4'-0"
8F8-OB/IT
I
#5
2561
1363
163
L45
4'-5"
5'-10"
BPS-OBAT
I
#5
1105
909
339
L50
5'-O"
L'-L"
8F8-OBAT
I
#5
1238
835
121
LLO
4'-8.
T-L"
8F8-OBAT
I
#5
1011
-121
534
LBO
8'-0'
9'-4"
BPS-IB/2T
1
#5
2
#5
152
591
512
L90
9'-0"
10'-L"
8F8-1B/2T
1
#5
2
#5
L43
530
401
L90B
9'-O"
10'-6"
8FiL-8/2T
ONE
1
#5
2
#5
1533
1183
401
1_I00
10'-0"
II'-4"
8F8-1B/2T
1
#5
2
#5
582
494
452
LIOOB
10'-0"
II'-4"
BFIL-6/2T
ONE
1
#5
2
#5
1364
1028
452
L120
12'-0"
13'-4'
8F8-iB/2T
1
#5
2
#5
411
428
324
L120B
12'-0"
13'-4"
BFIL-6/2T
ONE
1
#5
2
#5
1015
110
324
L140
14'-O"
15'-4"
BFiL-iB/2T
ONE
1
#5
2
#5
1250
409
259
LILO
IL'-O"
11'-4"
8F8-IB/2T
I 1
#5
2 1
#5
300
192 1
194
LILOB
IL'-O" 1
IT-4"
SFiL-8/2T
ONE
I I
#5 1
2
#5
950
500 I
I94
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED.
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) IOd x 1 1/2" nails -
( 24" o.c.) supporting Max.
18101bs, uplift
12
4
Aluminum Drip
Edge is Fascia
2.4,1"
Co Crete Anchors Per
Poured Concrete or Ma ufacturers Specs
concrete block wall \ ,l/4"Max.
2
Poured Concrete
concrete block wall
\121
\l�
Concrete Anchors Per n
Man upacturers Specs 2
Flash and Counter "
flash
Nail ledger to
gable end truss
with (2) IOd ils
at each web
I
I
1
I
I
I
t
i
I
I
I
I
Aluminum Panel
Sizes per manufacturer
- See Typical Stud Detail
7/8" x 3/32" wing Nut w/
'2
appropriate washer and spacing
per manuFactOurLer's Details
a
3"
c c
v A
Flush Mounted Shutter Detail
Stud Detall
Stud w/ Die Cast Zinc NTs
Nickel Plated Wing Nut
nts
Brace Gable end
with 2" x 4" SYP 42
8ft back nailed to bottom
of top chords using (2) IOd
nails at each truss
PRE-ENGINEERf-D WOOD TRUSSES
> 5 24"o.c. TYPICAL
( shop drawings by manufacturer )
to
to
Brace Gable end
with 2" x 4" SY1
aft back nailed t
of top chords usit
nails at each true
Aluminum Drip �"
Edge t Fascia
12"
2" x L" Sub-Fasel
Kaycan full o vent vinyl soffit installed
using I/e" dia shank x 15" long ga1v.
roofing nails with 3/8" dia. head per
product approval - see chart sheet #1
12" x 12" concrete column
block filled with concrete
and (2) #1 bars vert. tied
into lintels above
thicken edge to 8"xB"
with concrete and
one #5 bar continuous
i/2" thick stucco on 3/8' hi -rib lath
attached to horizontal and vertical wood
framing with nails or staples to provide
no less than 1-3/4" penetration into
horizontal wood framing and 3/4" penetration
into vertices wood framing members..::::�__
5/8" thick light textured
stucco on typical concrete block construction
V1���
Varies - see p
\R-30 blown fiberglass
in bottom chord of trusses
1/2" drywall with smooth Finish a
Two rows of beam block filled with concrete
and (1) 45 bar cost. in each row- Substitute
precast lintel filled with concrete and (1) U5
bar Cont. for bottom row over openings
1/2" dr wall over I" x furring
strips a IL" o.c. with R4.1 fi-foil
insulation on typical 8" Block walls
All drywall to be installed per FBC R102.3.1
and shall meet all pertaining ASTM codes.
Mortar to be Type "M" only proportioned per FBC RL01.I
and Mortar joints shall comply with FBC R60�.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
=
M
#5 bar vert. w/
30" overlap
p
at each filled cell
Strap truss to wall
using Simpson MGT with
Simpson
HETA 20
5/8' dia,
threaded
rod with min 12" embedment
hurricane anchor
at each truss
into beam
(22) IOd
truss leg
either wet
nails into
per detail
set or In epoxy with
truss. Add blocking to
on this sheet %
( 24" o.c.)
ti-}�T,q 2O 1810
supporting Max.
pp g
lbs. Uplift
L90
LLO
L90
BI
BI
BI
T
O
i
00
B I L90
�
LLO: �
<
LU
12 :3
~
\X//
B I L45
:
I
I U ca
12'
cn
u-o 2 X11
1 6 LOP
<
�C I
I
U
LLI
Q
+,
Q
oLU
E=E
CL
`>
L31 B I
toLU
U
B L45
O'+*��
-
O—
l.l��
0D
— —
v
O
111��
— —
--- ��-9r-- —---
Q
I Gulf Coast Supplu
and MFG 5v CrimD Metal roofing FL #II1.51.12
LU
woo screws with s
QL -� (type 2) 30 lb fel
-rov -atO
If sealing washer at 12" o.c. max spacing over ASTM D
underlayment installed with min. 4' side laps and L" end
laps fastened with
orrosion resistant tin caps and with 1.25" ring shank nail
to trusses usilig
attachment cletall on this sheet
A
IW/
B1
V,
X 3 . . .
.
1 Attic Acce"
4 FS L O P E with fight J
I I
D b ttom
I
8'—O" MAX.
T
p
) P o INT I I g1
ig (2) IOd
—�
O
(2) RU SE I I
--
-Br--�� I
12„
L31 BI I I
FLFL
I
I
I
I
I I
1 I I BI
O
L45 BI
1174
a
BI
,n <7/r
BI
m f-
W
ul
IL
lm s
P
HET
L50.
a S
Bi
Arricaile
an
hor
t o truss ..
LO
( 2
o.c
sup
ortl X.
BI
Bi
1810
lbs.
uplift
LO
L90B
A.
HETA 20
O
W
w
U)
X
OUrn
N �
O R
a
LLI
� � U
w
a OD
E_ z —
tn U (4
7
BEYOND
Rear Patio/Slab to
Fill cell with concrete and
#5 bar vert_ (typical).FL/4N
ROOF
be flush with bottom of
sliding door recess_ Wood
Max. spacing shall not exceed
48" unless otherwise noted
Top of footer Base
see foundation plan notes for
at
i II
OVERHANGS AT 1 -O UNLESS OTHERWISE NOTED ON THiS SHEET
IL below finished floor
Step per foundation plan
I
spacing openings
4" concrete slab with fibermesh OR
— ROOF PITCH AT 4:12 UNLESS OTHERWISE NOTED ON THiS SHEET
t
`s Slope per foundation plan
L"xL" Flo/lo WWM on L mil Visqueen over
clean compacted termite treated fill
- TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER
-
- ANY CHANGES TO THiS PLAN SHALL BE SUBMITTED TO THE
_
ARCHITECT FOR APPROVAL IN WRITiNG PRIOR TO STARTING CONSTRUCTION.
ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
I I INI�ii-
— '.:,;• `; 14"
8TO
- ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRiOR
,.
CONSTRUCTION FOR LAYOUT AND UPLiFT VERIFICATION
1111—
T (cal Section
at Front Porch
- CONTRACTOR TO PROYiDE FOR CORM BOARD SURVEY AND TO PROVIDEd
Scale " = '- "
FORM BOARD SURVEY TO TRUSS COMPANY PRiOR TO TRUSS CONSTRUCTION
.
Braden t Braden AiA, PA
Wgnne Building Corp. Date Drawn Revisions Sheet Comm #
Architects — Planners
_ 5-9-11
411 S.E. Coconut Avenue
Tel (112) 281-8258
The � rand Carlton GA��GEDrawn by:
-4 —
122�
C.C.U.
Fax : (172) 281-8283
E-mail: bradenalas'comcast.net
Spanish Lakes Checked b�:
Stuart. FL 34994 #AAC000032
St. Lucie Count( Florida D-R_B_ OF 5
COSil
PANEL
"A"
circ# Description Wire Load BR Poles
Poles
BR
Load
Wire
Description
circ#
2
40
1.0 kw
#8
A/C comp
1
2
AHU
#10
3.5 kw
30
2
3
4
2
#6
12.0 kw
50
2
30
4.5 kw
#10
40 gal. water HTR
5
6
Range
8
1
20
1.8 kw
#12
Pump
9
10
Dr er
#10
5.0 kw
30
2
II
12
1
20
1.5 kw
412
13
14
Dishwasher
#12
1.2 kw
20
1
1
20
1.5 kw
#12
Microwave
15
16
Refrigerator
412
1.2 kw
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
1-1
18
Recepts
#12
20
1
1
20
1.5 kw
412
Kitchen S.A.C.
19
20
Recepts
#12
20
1
1
20
1.2 kw
#12
Clothes Washer
21
22
Recepts
#12
20
1
I
20
0.81 kw
412
Garage Door Opener
23
24
Recepts
tt12
20
1
1
20
1.4 kw
412
25
26
Recepts
#12
20
1
1
20
1.92 kw
#12
2i
28
Recepts
#12
20
1
1
20
#12
General Lighting
29
30
Recepts
#12
20
1
1
20
#12
General Lighting
31
32
Recepts
412
20
1
I
20
412
General Lighting
33
34
Exterior GFCI
#12
20
1
1
20
#12
General Lighting
35
36
Bathroom GFI
#12
20
1
1
20
#12
Smoke Detectors
3l
38
General Lighting
#12
20
1
1
20
#12
Bathroom GFI
39
40
General Lighting
#12
20
1
S are
41
42
S are
PANEL "A" LOAD CALCULATION SHEET
Load Description
Qt
Watts
Total(Watts)
General Lighting (3 watts sq. ft.)
Small. ,,4,pplian,ce, ,C,ircuit(s).......... . . .... . . . .................
. Range.........................................................
Refrigerator
Microwave.....................................................
Dish Washer
.Clothes. W.psher.... . .... . .. ..................................
,Clothes, .Dryer ................................................
Water Heater
Water Pump
.Garage Door Opener ......... . . ..... ........ ........ .
1135
3
5,205
2
1,500
3,000
I
12,000
12,000
1
1200
1,200
1
1,500
1,500
I
1200
1,200
1
1,200
1,200
1
5,000
5,000
1
4,500
4,500
1
1800
810
1,800
I
810
Total
lUatts
31,415
First 10000 Watts e100% 1 1('),000 10,000
Remainder 21,415 940% 1 10,966
Electric Heat or A/C 10,000 965% 1 1(i.000 10,000
Calculated Load Watts 30,966
Voltage 240
Calculated Wattage Divided bg Voltage = Total Amps 129.03
Panel Size Required = 150 Amps'
Electrical SlUmbol Lie
S
Single Pole Switch
®
Recessed Can I ight
53
Double Pole Switch
®
Eyeball Recessed
Pe
Push Button Switch
-0-
Exhaust Fan
Duplex Outlet
Ceiling Mounted Light
Special Receptacle
O-
Wall Mounted Light
=E)clinterru
Waterproof ground fault circuit
PC
with Pull Chain (attic)
I Computer Conner tion Jack
Flood Light
Electrical Panel
Electrical Meter
Ceiling fan
®
Floor Duplex Outlet
©
crr
Carbon Monoxide Detector
�2
TQ
Thermostat
m
©
Central Vac
rc:::�
O
Smoke Detector
Television Jack
Telephone Jack
AC cxs c
A/C Disconnect
®
1 x 4 Florescent Light
®
2 x 4 Florescent Light
sP1cR
Speaker Hook -Up
Intercom
= JUNCTION BOX TO SUPPORT A FAN
O = THERMOSTAT LOCATION
B/A = BALANCED AiR
Electric Notes:
I. Use copper wire ono aluminum.
2. Provide and wire Alall required smoke detectors.
3. Contractor to verify location of electrical
service and provider.
4. ALL paddle fans shall be on a rheostat.
S. ALL bath and kitchen receptacles to be GFI protected.
6. ALL exterior outlets to be WP/GFI protected.
1. Recessed cans to be installed per NFPA requirements.
8. AFCI receptacles are required in all rooms except
Kitchen, Bathrooms, and Garage.
q. A/C Return Air Balance Must comply w/ FBC RMIL02
10. A/C Refrigerant lines that are run thru slabs must be
sleeved in PVC
11. ALL A/C Equipment shall comply with energy calculation
12. All work shall be performed by a licensed electrical
contractor, the completed system shall be fully operative.
13. Contractor shall pay for all fees, permits, testing, and
inspections including blower testing where required.
14. All work shall be coordinated with other trades to avoid
interference with the progress of construction.
15. All required insurance shall be provided for protection
against the public liability and property damage for the
duration of the work.
IL Contractor shall guarantee all materials and workmanship
free of defects for a period of not less than two years from
the date of acceptance or certificate of occupancy, or one
year from closing sale of house.
Correction of defects shall be completed without additional
charge and shall include replacements or repair of any
other phase of installation that may have been damaged-
163 CFM
IOxIox6
MASTER
BEDROOM
163 CFM
loxlox6
12xl2x9
B/A
Pr-, R--i
go 12xl2x9
B/A
PATIO/SLAB
GAR lAT
RO M
169 CFM Center Registers
IOxlOxl Ion ceiling \ n 149 CFM
IOxIOx71
H.B. CLOSE I `
CFM
° 8 x4 x4 Sox
I
I
8x4x4 J 12" 1
3 CFM -`1
Vent- ---- - ' � i I �
1 DINING
Soffit ATH �� ~ 1 ROOM
io°
20 C'
8x4x4
A/C
#I
Meter ISO Amp
Panel
153 CFM
12 xl2 x'l
.............
W.H. r
22" x 5 � I
Attic Ac ess
with light
L_____J
GARAGE
r----------------- I
I I
I I
I I
I i
I I
I I
I I
I I
I I
I I
I I
I I
M F. C J /4 N I C /4 L "4VOUT
SCALE: 1/,4" = I'-0"
11. It is not the intent of these plans to show every minor detail
of construction. The contractor Shall furnish and install
all items ford complete electrical system and provide all
the requirements necessary for the equipment to be placed in
proper working order.
18. All work shall be done in accordance with the N.E.C. and
shall comply with all local codes and ordinances, and shall
meet all standard requirements of the Iocal electric utility
and telephone company.
19. The electrical system shall be completely and effectively
grounded as required by the latest edition of the N.E.C.
20. All material shall be new and shall bear underwriters'
labels where applicable.
21. All equipment and panel sizes shall be verified before
ordering. The contractor shall provide circuit routings to
suit the job conditions.
22. Furnish and install all fixtures aS called for on the plans
or as selected bg others.
23, All raceways and pipes placed in or through any concrete
slab shall be spaced a minimum of three diameters of the
largest conduit or pipe from any other service.
24. All exposed wire below q -I shall be installed in metal EMT
conduit.
25. Dryer Vents to be installed per FBC RM1502
R7A1
20x2O
T I
j I
J 1
I
I
F Lu
:3 O I
I Q� II I
iL--� �' i
Lc__I!
232 CFM
12x6xi
e4xSECOND
�xCP \� BEDROOM
i
j 12xl2x8
B/A
COVERED
PORCH
A/C disc.
150
#2/0 Aluminum feed MCP
I %," Conduit PANEL
7MT:E�
2AH
2" PVC ( FPL)-�
2" rigid service Ff'L Bare #6 copper wire
to 45 cont. rebar in slab
ELECTRICAL RiSER
- Contractor shall use AL-CU Landing lugs. NTS
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
H.B.
Vent thru
Soffit
• B • Architects Planners
411 S.E. Coconut Avenue
B E-mail: bradenaia15 comcast. met
-
Fax (112) :::
Stuart. FL 34996 UAAC000032
Exhaust Duct
Thru Soffit
4" Exhaust
Duct Thru
Wall
WP GFCI
Install oulet
under disc.
not shown I
clarity _
0
ELECTL PLAN
PATiO/SLAB
SCALE: 1/4" = 1'-0"
Attic ventincq Calculations FBC 2309.1
Total Attic Space = 212-1 sq. ft.
Venting Ratio 1/150 = sq, ft. required
Rrovidle A Continuous Vented Soffit
Wynne Building Corp.
The Grand Carlton
Spanish Lakes
St. Lucie County Florida
Post Light with
Photo cell I
Date Drawn ; Revisions
5-9-1-1
GARAGE Drawn by:
LEFT C.C.u_
Checked by:
D.R.B.
Sheet
Exhaust Duct
Thru Soffit
Wire For
Front Post
Light
Comm It
12 2� �.
`, �