HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
r Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: THE GRAND CARLTON
Builder Name: WYNNE DEVELOPMENT
Street: WYNNE DEVELOPMENT
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL ,
Owner: 55 �'. `k S � `(,\
Permit Number:
Jurisdiction:
Design Location: FL, ST_LUCIE_CO_INTL
County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1437.3 sqft.)
insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ftz
b. Frame - Wood, Exterior
R=11.0 187.33 ftZ
3. Number of units, if multiple family 1
c. N/A
R= ftZ
4. Number of Bedrooms 2
d. N/A
R= ftZ
10. Ceiling Types (1446.0 sqft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1446.00 ftz
6. Conditioned floor area above grade (ft2) 1446
b. N/A
R= ftz
Conditioned floor area below grade (ftz) 0
c.
R= ftz
11. Ducts
R ftz
7. Windows(139.2 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 320
a. U-Factor: Dbl, U=0.54 99.23 ftz
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.55 40.00 ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ftz
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftz
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.586 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1446.0 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1446.00 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
15. Credits
Pstat
Glass/Floor Area: 0.096 Total Proposed Modified Loads: 46.91
PASS
Total Baseline Loads:- 48.19
I hereby certify that the plans and specifications covered by
Review of the plans and
4'YKE ST
this calculation are in compliance with the Florida Energy
specifications covered by this
O��
Code.
calculation indicates compliance
vj iiq ' = - ,"0
",�
with the Florida Energy Code.
nu�''% `, r ''�•:�
O'�
PREPARED -BY'
Before construction is completed
r
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
COD WE't'��
OWNER/AGAIN'
BUILDING OFFICIAL:
DATE: �j
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
File COPY
7/6/2017 8:51 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
rORM R405-2014
7!q
PROJECT
Title: THE GRAND CARLTON
Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1446
Lot #
Owner:
Total Stories: 1
Block/SubDivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT
Rotate Angle: 135
Street:
WYNNE DEVELOPME
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
ST. LUCIE COUNTY
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
FFL,
IECC Design Temp
Int Design Temp Heating Design Daily Temp
V Design Location
TMY Site Zone 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 2 39 90
70 75 299
58 Medium
BLOCKS
Number Name
Area
Volume
1 Entire House
1446
11568
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1 BEDROOM
234
1872 No 2
1 1 Yes
Yes Yes
2 WIC
3
54
432 No 0
1 No
Yes Yes
MASTER BATH
63
504
4
No 0
1 Yes
Yes Yes
M. BATH
5 KITCHEN
56
448 No 0
1 Yes
Yes Yes
6
BATH
172
1376 Yes 0
1 No
Yes Yes
7
BEDROOM 2
45
360 No 0
1 Yes
Yes Yes
8
LAUNDRY
204
�
1632 No
1
1
9
42
336
1 Yes
Yes Yes
GREAT/DINING
No
0
10 FOYER
526
4208
No
i Yes
YeS YBB
50
400 0
No
i Yes
Yes Yes
0
# Floor Type
FLOORS
Yes
Yes %s
1 Slab -On -Grade Ed_
Edge Insular��
Space.
1 Peri metr Pp,;m..._ _
2 Slab -On -Grade Edge Insulatio
I p0ft,
/
— 3 Slab -On -Grade Edge Insulatio
WIC �,
MASTER BATH
4 Slab -On -Grade Edge Insulatio
M. BATH
5 Slab -On -Grade Edge Insulatio
KITCHEN
6 Slab -On -Grade Edge Insulatio
BATH
7Slab-On-Grade Edge Insulatio
BEDROOM 2
`x-Value
Area
234 fv
0
54 #z
0
63 ft.-
0
56112
0
172 ft2
0
45 {t2
n
Tile Woo
0 0
1 0
0
0
0
O
Page 2 of 5
FORM R405-2014
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 47 ft 0
526 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio FOYER 7 ft
0
50 ft2
----
0
1
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
#
Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1
Gable or shed Metal 1524 ft2
240 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1446 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) BEDROOM
30
Blown
234 ft2
0.1
Wood
2
Under Attic (Vented) WIC
30
Blown
54 ft2
0.1
Wood
3
Under Attic (Vented) MASTER BATH
30
Blown
63 ft2
0.1
Wood
4
Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
5
Under Attic (Vented) KITCHEN
30
Blown
172 ft2
0.1
Wood
6
Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
7
Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
8
Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9
Under Attic (Vented) GREAT/DINING
30
Blown
526 ft2
0.1
Wood
10
Under Attic (Vented) FOYER
30
Blown
50 ft2
0.1
Wood
WALLS
Adjacent S10 IAIqll Typepace Cavity Width
Height
Sheathing Framing
Solar
Below
1
N=>SE
Exterior Concrete Block - Ext InsIREDROOM
4.1 9
0 8
0
72.0 ft2
0
0
0.5
0
2
S=>NW
Exterior Concrete Block - Ext InsfilEDROOM
4.1 18
0 8
0
144.0 ft2
0
0
0.5
0
3
W=>NE
Exterior Concrete Block - Ext InsiHEDROOM
4.1 13
0 8
0
104.0 ft2
0
0
0.5
0
4
S=>NW
Exterior Concrete Block - Ext Ins ASTER BA
4.1 9
0 8
0
72.0 ft2
0
0
0.5
0
5
S=>NW
Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.5
0
6
N=>SE
Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.5
0
7
N=>SE
Exterior Concrete Block - Ext InREDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.5
0
_ 8
E=>SW
Exterior Concrete Block - Ext InOEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.5
0
9
SE=>W
Exterior Concrete Block - Ext InfiEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.5
0
10
S=>NW
Exterior Concrete Block - Ext InQEDROOM 2
4.1 4
0 8
0
32.0 ft2
0
0
0.5
0
11
S=>NW
Exterior Concrete Block - Ext InsUTAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.5
0
12
N=>SE
Exterior Concrete Block - Ext InsGiREAT/DINI
4.1 26
0 8
0
208.0 ft2
0
0
0.5
0
7/6/2017 8:51 AM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
WALLS
Adjacent Space Cavity Width
Typ
Height
Sheathing Framing Solar
Below
13 W=>NE Exterior Concrete Block - Ext InsGREAT/DINI 4.1 21 0 8
14 N=>SE Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8
15 E=>SW Exterior Concrete Block - Ext Insul FOYER 4.1 6 0 8
16 N=>SE Exterior Frame - Wood GREAT/DIN[ 11 23 5 8
0 168.0 ft2
0 8.0 ft2
0 48.0 ft2
187.3 ft2
0 0 0.5
0 0 0.5
0 0 0.5
0.23 0.5
0
0
0
0
DOORS
# Ornt Door Type Space
Storms
U-Value Width Height
Ft In Ft In
Area
1 E=>SW Insulated FOYER
None
.28 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
V # Ornt ID Frame Panes NFRC
U-Factor SHGC
Overhang
Area Depth Separation Int Shade
Screening
1 W=>NE 3 Metal Low-E Double Yes
2 S=>NW 5 Metal Low-E Double Yes
3 E=>SW 8 Metal Low-E Double Yes
4 N=>SE 12 Metal Low-E Double Yes
5 W=>NE 13 Metal Low-E Double Yes
0.54 0.25
0.54 0.25
0.54 0.25
0.54 0.25
0.55 0.25
32.4 ft2 1 ft 0 in
6.9 ft2 1 ft 0 in
23.2 ft2 1 ft 0 in
36.8 ft2 1 ft 0 in
40.0 ft2 10 ft 0 in
1 ft 4 in Drapes/blinds
1 ft 4 in None
1 ft 4 in None
1 ft 4 in None
1 ft 4 in None
Exterior 5
None
None
None
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 315ft2 315ft2
24ft
8ft
11
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356
1349.6 74.09 139.34 .2669
7
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type Subtype
Efficiency
Capacity Air Flow SHR Block
Ducts
1 Central Unit Split
SEER: 15 34.8 kBtu/hr
cfm 0.85 1
sys#1
7/6/2017 8:51 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
a
1 Electric
None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
ft2
DUCTS
V
— Supply —
--- Return ---
Air
CFM 25
CFM25
HVAC #
#
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 320 ftz
Attic
80 ftz Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolin ]Jan
Heating X] Jan
]Feb
X] Feb
]Mar
X] Mar
E
A r
Apr
JMa rj JunX Jul
MayJun r l Jul
X Au
4 Au�Xj
Se
Sep
Oct
Oct
Nov
Nov
H
H Dec
Dec
Ventin [ ]Jan
[ ]Feb
X Mar
[X
A r [
Ma Jun Jul
[ Aug
Se
[xl
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
7/6/2017 8:51 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 5
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT
Street: WYNNE DEVELOPMENT Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, ST_LUCIE_CO_INTL
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and. the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/doorjambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
airtight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
7/6/2017 8:51 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
7
{ FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz
7. Windows-
Description
a. U-Factor:
Dbl, U=0.54
SHGC:
SHGC=0.25
b. U-Factor:
Dbl, U=0.55
SHGC:
SHGC=0.25
c. U-Factor:
N/A
SHGC:
d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
WYNNE DEVELOPMENT, FT. PIERCE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1250.00 ftz
b. Frame - Wood, Exterior
R=11.0
187.33 ft
1
c. N/A
R=
ftZ
2
d. N/A
R=
ftz
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1446.00 ftz
1446
b. N/A
R=
ft2
Area
c. N/A
R=
ftz
11. Ducts
R ftz
99.23 ftz
a. Sup: Attic, Ret: Attic, AH: Attic
6 320
40.00 ftz
12. Cooling systems
kBtu/hr
Efficiency
ftz
a. Central Unit
34.8 SEER:15.00
8. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
b. N/A R=
c. N/A R=
ftz
13. Heating systems
kBtu/hr Efficiency
a. Electric Heat Pump
34.8 HSPF:8.50
3.586 ft.
0.250
Area
14. Hot water systems
1446.00 ftz
a. Electric
Cap: 40 gallons
EF: 0.97
ftz
b. Conservation features
ftz
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: _� Date: q V-I
Address of New Home:S S ���`�QS � City/FL Zip:: et�p
TFIE STq��o�+
wIE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/6/2017 8:51 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
File Copy.