Loading...
HomeMy WebLinkAboutSET-UP MANUAL ADDENDUM 8-29-17SCANNED By SET-UP MANUAL ADDENDUM AU6 2 9 201 public Works S . Lucie County, FL JAICOBSEN HOMES 600 PACKARD COURT SAFETY HARBOR, FLORIDA (727) 726-1138 NOTICE These specifications and drawings are original, proprietary, and confidential materials of Jacobsen Manufacturing, Inc. Such materials are provided to the reci ienter specific purposes and must be kept confidential and secret from others. ��� 0 REV 01 /10 ALL HOMES SET IN FLORIDA MUST COMPLY WITH DMV RULE 15C EFFECTIVE MARCH 29,1999 For information on 15C- contact the Department of Motor Vehicles 850-413-7600 1 ADDENDUM EXTERIOR HEATING/COOLING DUCT DUE TO THE NEW THERMAL REOUIREMENTS INSTITUTED BY HUD, THE INSULATION VALUES OF THE MANUFACTURED HOME HAVE INCREASED. IT IS NOW NECESSARY FOR ALL EXTERIOR DUCTS INSTALLED ON JACOBSEN HOMES HAVE A MINIMUM R-VALUE OF 8. ALL HEATING AND/OR COOLING SUPPLY AND RETURN DUCTS EXPOSED DIRECTLY TO THE OUTSIDE AIR, SUCH AS UNDER CHASSIS CROSSOVER DUCTS OR DUCTS CONNECTING EXTERNAL HEATING, COOLING OR COMBINATION HEATING/COOLING APPLIANCES SHALL BE INSULATED WITH MATERIAL HAVING A MINIMUM THERMAL RESITANCE OF R=8.0, WITH A CONTINUOUS VAPOR BARRIER HAVING A PERM RATING OF NOT MORE THAN I PERM. WHERE EXPOSED UNDERNEATH THE MANUFACTURED HOME, THE DUCT SHALL NOT BE IN CONTACT WITH THE GROUND, DUCT SUPPLY OR RETURN X I Ib i TYP. FLOOR SYSTEM TO HEATING/CGOLING OR CROSSOVER USE MINIMAL AMOUNT OF DUCT. LIMIT DUCT USAGE TO REDUCE THE AMOUT OF BTU/110UR LOSS. DO NOT OVER BEND OR CRIMP FLEX DUCT THIS WILL RESTRICT THE AMOUNT OF AIR FLOW THROUGH THE DUCT. USE STRAPPING OR OTHER MEANS OF SUPPORT TO PREVENT THE DUCT FROM COMING IN CONTACT PATH THE GROUND. PLACE STRAPS AS NEEDED TO SUPPORT DUCT (DO NOT RESTICT AIR FLOW BY OVER TIGHTENING SUPPORT STRAPS). ALSO SEE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR DUCT INSTALLATION AND SUPPORT. A APPROVAL:oN TES• AkDAR PROVED BY JUN 1 5 10 '1 f NC me ri NOTICE DRAYM BY: • DATE: REV. LITTER: JACOBSEN HOMES TKsE SP ancATIDNS AND DRAV"M ARE C.L.Y. 5-30-95 ANAL, PRDPRtETARY, AND rANFiDETITIAL DRAWING TITLE: P.O. BOX 368 ATEFIALS Of JALO(iSEN YANJFACTUR711C EXTERIOR A/C DUCT !IC SUQi YAIERYI$ ARF PROVIDED i0 1HE SAFETY HARBOR, FLORIDA 34695 �Q'ENt rat SPEQi1C PlFKO45 APO MUST BE DRAWING NUMBER. PHONE (813) 726-1138 Id�T DDrtDonuL AIO Yai[T IRpI OtNEiis AD—AC-0001 ..2 ADDENDUM WHOLE HOUSE VENTILATION SYSTEM YOUR HOME HAS BEEN EQUIPPED WITH A 'WHOLE HOUSE' VENTILATION SYSTEM. THIS SYSTEM HAS BEEN DESIGNED TO MEET ALL THE REQUIREMENTS SET FORTH BY THE UNITED.STATES DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT. THE WHOLE HOUSE VENTILATION SYSTEM IS REQUIRED (BY HUD) TO EXCHANGE AIR DIRECTLY WITH THE EXTERIOR OF THE HOME. THE PURPOSE OF THIS SYSTEM IS TO GIVE THE HOME OWNER THE ABILITY TO INTRODUCE FRESH OUTSIDE AIR INTO THE INTERIOR OF THE MANUFACTURED HOME, INSTEAD OF SIMPLY RE— CIRCULATING THE SAME OLD, STALE AIR THROUGHOUT THE HOME, THUS IMPROVING THE INDOOR AIR QUALITY. THE SYSTEM INSTALLED IN YOUR HOME HAS BEEN DESIGNED TO GIVE YOU COMPLETE CONTROL OF WHEN AND HOW THIS SYSTEM IS USED. YOUR HOME IS EQUIPPED WITH A FAN THAT WILL EXHAUST STALE INDOOR AIR (TO THE EXTERIOR OF THE HOME). THIS FAN IS SWITCH CONTROLLED AND MAY BE MANUALLY OPERATED. TO DI4zCONT!"!UE USE OF THIS SYSTEM, SIMPLY 'TURN OFF' THE SWITCH THAT CONTROLS THE FAN. NOTICE TO HOMEOWNER Whole house ventilation switch You will be able to locate the switch that controls this fan by locating the switch that is labeled -WHOLE HOUSE VENTILATION. (See AD-AC-0100) APPROVED BY 1N14Sit INC. 1lI1fWWWC mm" oa o�row "811"a a JACOBSEN HOMES 1185E SK"UTTMS' AND DRAMIMOS ART: `r°^"DI: C.L.Y. V^�G: s-2a-s5 ^C T. iCI I:^: ■ F.O. BOX 368 CMMUM, ►ROPI TMT. AND CONf10E1M& MATERIALS OF JACOOMN WVUFACTUF Mt: DRAWING TIRE- W.H. VENT. SYS. Q „ SAFETY HARBOR. FLORIDA 34695 REST ►at sporiSC pAppMPRWA O MA K DRAWING NUMBER PHONE (813), 726-1138 PVT C&IMIIAL NO SEWT 11101 0114n AD—AC-0100 3 ADDENDUM MULTI -WIDE UNIT FLOOR FASTENING FLOOR JOIST 0.1310 ) NAILS OR 7/ STAPLE! 0.016') - - --- STRAP ® 48' O.C. MAX. SPACING WITH FASTENING INTO JOIST EACH SIDE OF CENTER LINE PER TABLE BELOW: STALLED SEE NG, STAGGERED APPROX. 45' DETAIL BELOW )ORS. 1/4 0 TO 3 4' GAP �-- INSTAL! WOOD SHIM AT ALL LAG FOR GAPS IN FLOOR SYSTEMS —� TO 1/Y, IINN ' SE LAG LENGTH 1' LOCATIONS FOR LAG SCREW TO GO NDS01 THROUGH AND TO KEEP CONNECTION AND FOR GAPS TO 3/4'. INCREASE (ALL ZONES) LAG LENGTH 1 1/2% TIGHT. (SE NOTE 2) (ALL EXPOSURES) wm mw ExA MK 3/d x 3 1/2- LAG MEN 30 GIL 7/18- � OAP FASLEIJED W/ 1• GA. STAPLES V" 201E DMPOSURE WH M !UMBER OF FASTA:iERS RE"M WAN" SPACIMG HAM M SPAON 0.131- X 1 L/I NALS 7/1Mr X 16 GAL SUPLES 'e Ir O.C. 2 1/4' aG 1 3 S 2 2 v 1r O.C. 1 7/r OG b' 4 7 'v 1E' O.C. C r at 'C 4 7 3 3 b' 16* at 1 1/Y O.C. b' 5 e NOTESe I. 1' WK Pt7i1RAT10N LS Rmme ON STAPLES FOR mK a011' 2. w000 SLAG TO BE RPPED FROM SPF 03 UK OR Kim (r X 1. 11 GAP rB1H WK SIZE) OSB OR PLYWOOD WAY BE USED F ViONSS EQUALS GAP X 4. SEE OM DETAILS FOR SEALING FLOORS FOR AIR KLTRATOL EHGL'EER APPROVAL' X 4' WDL Smq John C. Croetlen. P.I-. APPROVED BY Revised May 24,2006 INC. FEDEML MAMUFACfURED MOIAE CONSTPUCTION AMU yA ETY STANDARDS JACOBSEN HOMES N0T7M Mo =ANN= M nrESM: VEOW-AS Es AE ORMM. 1 RWMTMT AID Oa10E "m MAIDU S a MADI M U~AC7URW w" BY. M.T. DATE 05 -22-06 REV. LETTER c DRAW TITLE:P.a M/W FLOOR FASTENING Box 3ca 011-F-171MNC 301 IMIU MJ AM PRvA XD M TM[ DRAr.+c NuueErt AD-FA-0001 rrm S PHa+E(813j 2266-ro113809S 1am+�ml�MMPOW e.um o MW It am ADDENDUM MULTI -WIDE. UNIT WALL FASTENING ENDWALL NDS01 .131' X 3 1/2' MIN. NAILS 8' O.C. MAX. SPACING, STAGGERED FROM SIDE TO SIDE (TOE —NAILED). MARRIAGE LINE NOTE:. D OW M"WAL• MIA AiPwftl• 1. FASTENING REQUIRED ONLY AT MARRIAGE LINE OF APPROVED BY EXTERIOR WALLS.ON Revised S Zj Gb May 24,2006 Uuhn C. Ogaden, P.L INC. K2 Engineering, Ina F101FAL MAI l MMO "°" E ca"Smalm am SAFETY Srr OAVAS JAC O BS EN HOMES mm eoLfIG I Gm= AK MAIM M.T. DA1E 05-22-06 P.O. eox MOVES w doom WMIAe}♦m M/W WALL FASTENING U LRE Me 2 01 VA>DULS AV Ma�cm to >tt SAFETY HARBOR, FLORDA 34695 ®ort 1 lane MIEM AIO nsi K DRAW NMiI M P►IOHE (eta) 726-1138 ICI ar -496 A � ITS olm AD—FA-0010 5 ADDENDUM MULTI,,,, WIDE ROOF FASTENING CENTER LINE OR MATING UNE OF TRIPLE WIDE UNITS 30 'GA. 'GALV. STEEL STRIP I SECURED WITH 7/16• X 16 GA. STARD FULL PENETRATION INTO DECKING (SEE CHART CN AD-FA-0001 MAX SPA G). 30 GA. GALV. SNEL STRIP 8- X LENGTH OF ROOF (SECTIONS MAY BE OVERLAPPED 2- MIN.) W/STAPLES AS SHOWN. INSTALL ROOF CAP PER SET- UP MAN. OVER GAL STRIP. I (30 GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS REMOVED FROM **LAG SCREW SET BACKS ROOF IN ORIGINAL CONDITION, FOR TRIPLE WIRES EXCEPT FOR STAPLE HOLES.) FOR DOUBLE WIOES�\ PAN VIEW 1 4' 2 3 V 3/8' X r LAG SCREWS AdAGSCREW SET BACKS TRIPLE WIDE ROOF LINE (2 I/4' SMOOTH SHANK) FOR DOUBLE WDES - INSTALL LAG SCREWS _ SEE CHART ON AD-FA-0001 FOR TRIPLE WIRES AT A 45' ANGLE I FOR MAXIMUM SPACING STAGGERED 2 1 4' 23 4' 1 4' TO 3 4' GAP -_ ROOF PERIMETER RAIL-1' I I OR RIDGE BEAM (FOR RIDGE BEAMS SEE NOTE 14) CROSS-SECTION OR FGAPS TO 3/4', INCREASE INSTALL WOOD SHIM AT ALL LAG TO 1INCREASE LAG LENGTH iE FOR GAPS IN ROOFSYSTEMSI* LOCATIONS FOR LAG SCREW TO GO AMOR THROUGH AND TO KEEP CONNECTION NDS01 LAG LENGTH 1 1/2'. TIGHT. (SEE NON 2) (ALL ZONES) CROSS-SECTION (W/GAP) C wA si 0 - 91.07 (ALL DPOSURES) NOTES: /LfiM APPROVAL• DAM APPROVAL' L 2 1/a' 111L PEIIEIRATIOt1 NTO RECf]MIC MOM 6 REO1MEM FOR LAC SCRIM 2 ROW SHl119 TO K RM'PED FROM SPF p MIL OR KiIER APPROVED BY r X r X CAP WDTH MIL Smo ON �03 OR FLYMl= MAY BE IWI F WIIC1 OS EQUALS GAP WMA 1 SEE OM MIMS FOR MM UIDIG ROOF MEREC70 L ' X C W 5ft Wn, evised ay P1 'I 4. *IEN INSTALLAG A LAG SC1Etr KM RIDGE �gilll ti.P �. N24,2006 I (� I C A OAK HEST-m HCIE T1itM TIE FIRST WM BEA1L SEM-M A 1/4' HOIE k 3/C L1EARANCE K2. EngirTeern1g, Inc . FEDERAL MANUFACTUREDI MvOME RECEINNO R06E KM FOR 1IE MAW PMIM OF LAG SCE VIOUGI lK D£SE DNS ARE CONSTRUCTION AND SAFETY STANDARDS FOIL 3/V LAC 30tEVIS OILY. S 10e UAMN SnEJUIEL HEIGR. J AC 0 BS E N H 0 ME S NOTICE 1IEg sFt:aTeATFDIs ATo (RATflDS ARE DRAIN 9Y M.T. OAT% 05-22-06 AE1f. LE11Fit Mo �P P.O. sox 3aa aWKk PRIPMAR'W. AM ammmnK ,I- MAXIMS Tug AK � "PTO DRAWS AIlE M/VY ROOF FASTENING 34695 DRAIIRIG NUI®Elt PSAFEHONE (8113) 72A-1D 13a IA �Oo N" me Mla nw dro AD-FA-0020 6 METAL ROOF RIDGE CAP DOUBLE WIDE UNITS ONLY PLAN VIEW 29 GA. MIN. GALV. STEEL RIDGE CAP COVERING IBM OF ROOF (MK Y OVERLAP AT SEAL CENTER OR MATING LINE SECURED WITH p X 7/16' HEAD X f FULLY THREADED SCREW AT EVERY RIB (AND ON BOTH SIDES OF RIB WITHIN END ZONE) I I I I• I I I• 8 X 7/16- HEAD X f LLY THREADED REW RIDGE CAP (NO MORE THAN 2. 0.11)uj I i o i I i 6 m Lo ASPHALT IMPREGNATED 1 1 SEALER STRIP BETWEEN RIBS OR CLOSURE STRIP RUNNING 1 1 ENTIRE LENGTH OF ROOF I 1 , I 1 METAL ROOF PANELS STOP 1 , 1 APP. 3" FROM CENTER LINE , I , , Ref: EX-13-0051 and M GA. GALV STEEL STRIP AD-FA-0020 6SECUM WITH UNGTH X 116 rSEE GsrA) NDS01 FULL PEEN71ON INTO DECIONG (ALL ZONES) (SEE CHART ON AD-FA-00DI MAX SPACING) (AL- EXPOSJRESI NOTES: 90M A"MAU DAM AaPA AL 1. SEE OTHER DETAILS FOR CONNECTIONS BETWEEN SECTIONS APPROVED BY Z. STANDARD 7/1C O.S.B. (24/16 INDEX) ROOF SHEATHING 3. METAL PANELS ARE 29 GA. MIN. STEEL WITH a QC. RIBS V �j 00oON P, if 10,2008 4. SCREWS HAVE A NEOPRENE WASHER FOR WEATHER PROOFING AND Q DW:;VD, F'.� I NC,. FEDERAOW TO HELP AVOID OVER DRIVING. IF SCREW IS OVER DRIVEN CONSTR MONAMANUFAcrSAF SAFETY �� EnG consrnurno„axosutrrsru,ou,os ANOTHER SCREW MUST BE ADDED BESIDE THE INEFFECTIVE SCREW (DO NOT REMOVE OVER DRIVEN SCREWS) JACOBSEN HOMES ► D.M.T. DA7� 08-25-08 am PA Box 363 BIG sm MA1n" ME mwm 1011E METAL ROOF RIDGE CAP — s H (M3)�m1138 wr o mmm muBw� �►rwc AD—FA—D021 7 ADDENDUM MULTI=WIDE ROOF SEALING/CLOSE-UP MIN. 30 GA. GALV. STEEL STRAPPING (SEE AD-FA-0020) 6" STRIP ROOFING CEM RECOMMENDED OVER EDGES NOTES: 1. 30 GA. GALV. STRIPS USED MAY BE WIND DE REMOVED FROM ROOF IN ORIGINAL CONDITION (EXCEPT FOR STAPLE HOLES). 15# FELT UNDERLAYMENT 0 MULTI -WIDE ROOF LINE BEAD OF ROOFING CEMENT RECOMMENDED EACH SIDE BY JM 1 5 1995 INC JACOBSEN HOMES I NOTICE: MAN" C.L.Y. 6-5-95 . THESE SPEQl1CATDNS AND DRAWNGS ARE DRfpNA� PRDPPoETARf. AND H�Nf100iT1AL DRAWING TITLE WETY P.O. BOX 368 uwTEtaus YANUFAGTl1tWG M/W ROOF SEALING RIG 9101 uAlEPoA15 ARE PRDNDED m T¢ PHONE (813) 7281D;�4695 RE, T ��TP P �s� o� DRAWING NUMBER AD—FA-0025 8 ADDENDUM MULTI -WIDE ROOF SEALING/CLOSE-i1P MIN. 30 GA. GALV. STEEL STRAPPING (SEE AD-FA-0020) • 6" STRIP ROOFING CEMENT REQUIRED OVER EDGES - HIGH SIDE 15# FELT UNDERLAYMENT _zz's 6" STRIP ROOFING CEMENT RECOMMENDED OVER EDGES - LOW SIDE . NOTES: 1. 30 GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS REMOVED FROM ROOF IN ORIGINAL CONDITION (EXCEPT FOR STAPLE HOLES). MULTI -WIDE ROOF LINE BEAD OF ROOFING CEMENT (2 BEADS REQ'D HIGH SIDE 1 BEAD RECOMMENDED ON THE LOW SIDE) BY JUN 1 5 W5 INC JACOBSEN HOMES N0T1C IAI(ATM tlT: UAIC: MI. ����^• THEM sPEnTlcwlloes AND DRAWINGS ARE C.L.Y. 6-5-95 OMONA4 PROPMETARY, AND CGN UNTIAL DRAWING 71TIL- MATIRIAIS OF JACODSEN MANSACT"C M/W ROOF SEALING P.O. BOX 368 We 9" MATERIALS ARE PRONGED TO THE SAFETY HARBOR, FLORIDA 34695 KOPEHT FOR W(CM PUIPM No Musa BE DRAWING NUMBER: PHONE (813) 726-1138 IQPT for wnAL NO IMT rtwM OTKn AD—FA-0026 PI HEARTH. INSTAT I.ATICIN- I. REMOVE ANY CARPET AND/CR PA 2. INSPECT THE MEAL FlASHNG IN BEEN INSTALLED (THIS FIASHUNG I AREA BETWEEN THE FIREPLACE AT 1 LOCATE THE HEARTH DMNSON THESE STEPS A CARMY PLACE THE HEA OF THE FIREPLACE ASSEUB B. SECURE THE HEARTH OM C. FILL THE AREA BETWEEN TF WITH A NON-COMBUSTABLE D. OR FOLLOW THE HEARTH M, TILE SURROUND TYP. HEARTH (MAY BE SHIPPED LOOSE) FROM UNDER THE HEARTH EXTENSION AREA LE HEARTH AREA TO INSURE THAT IT HAS iST BE PLACED ON THE FLOOR TO PROTECT THE THE HEARTH). IPPED LOOSE IN THE HOME) AND INSTALL FOLLOWING EXTENSION IN THE PROPER LOCATION IN FRONT )N TO THE FLOOR W/ 4 j8 x 2' WOOD SCRLITS FACE OF THE FIREPLACE AND THE HEARTH EXTENSION AU XING OR MORTAR. JFACTURETRS INSTRUCTIONS FOR INSTALLATION. 1. A TYPICAL TILE FRONT FIREPLACE IS SHOWN, HOWEVER THIS DETAIL APPLIES TO ALL FACTORY INSTALLED FIREPLACES. (STONE, WOOD, GYPSUM, ILE, STUCCO, ETC... MAY BE USED IN LIEU OF THE TYPE OF FIREPLACE SURROUND SHOWN ABOVE.) TYPICAL WALL WOOD TRIM FACTORY INSTALLED FLASHING DAPIA APPROVAL: APPROVED BY JW 2 8 T9% INCON 14 NOTICD DRAWN BY:. DAZE: REV. LETTER: JACOBSEN HOMES T�NESE SPECONJUIONs mm DRAWINM ARE C.L.Y. 6-16-95 ■ �fEONAL, pROFfCCTARY, AND CONIIOENTIAL DRAWING TITLE P.O. BOX 368 uATERIALS OF JACOBSEN uNAlFACVWG SHIP —LOOSE HEARTH „ YK 9JW MA1ER►45 ARE FRONDED TO THE SAFETY HARBOR, FLORIDA 34695 FCR 9'ECx1C PIAPOEIS AND MST K DRAWING NUMBER PHONE (813) 726-1138 lul COI MTK no Nov rKm orrm AD—FP-0001 10 SMOKE ALARM ADDENDUM Enclosed in the home owner's packet is the smoke alarm user's manual, (if it is not there, contact Jacobsen Homes and one will be sent to you. NOTICE TO DEALER AND SET-UP PERSONNEL This home is equipped with a smoke alarm system and must be tested in accordance with the smoke alarm user's manual after the home is completely set-up and all the electrical connections are done. NOTICE TO CUSTOMER Smoke Alarms have been installed in your Jacobsen Homes. You should be familiar with the locations and operation, and learn how the alarms can be silenced once they have sounded and be familiar with its use. This is a very important safety device installed for your protection. Be sure that it is kept in A-1 working condition by testing if frequently in accordance with the manufacturer's instructions. The alarms operate on household current, and have battery backups. Its purpose is to provide early warning in case of a fire. Again we stress the importance of keeping your smoke alarms in proper working order. TESTING SMOKE ALARM Test smoke alarms after home has been set-up completely. To test the smoke alarm, press and hold the test button on the cover of the unit, until the alarm sounds. All smoke alarms should sound alarms. If all units do not alarm, replace units immediately. This test should be given to all smoke alarms individually. APPROVED BY REv. N114W 2 5 20 INC. FEDERAL 61ANUFACTURED HOME CONSTRUCTION AND SAFELY STANDAHUS SET UP MANUAL ADDENDUM AD-FS-0001-A TRUSS SHEATHING APPROVED BY INC. fTDERAL MANU6ACNRED HOME COMSTRUCTlONMD SAFETY STA6DAR06 DEALER (SET-UP)INSTALLED PLYWOOD FOR SHEATHED TRUSSES NOTE: HOLES TO BE CUT IN SHEATHING TO ALLOW HINGED TRUSS OUTLOOKERS TO PASS THROUGH. ,� TYP. OUTLOOKERS FACTORY INSTALLED PLYWOOD FOR SHEATHED TRUSSES L SIDEWALL 3/8' MIN. APA OR TECO RATED SHEATHING APPUEDITO ROOF TRUSSES LOCATED DIRECTLY ABOVE SHEARWALLS (APPLICABLE TO ALL SHEARWALLS) MARRIAGE WALL PENETRATIONS OF THE SHEATHING ON THE TRUSS(ES) FOR I- THE OVERHANG OUTLOOKERS (PURUNS), ATTIC VENTALAMON. 3/8' SHEATHING TO BE INSTALLED ON -SITE OPENINGS IN TRUSS SHEATHING MAY BE LOCATED AT ANY LOCATION ALONG THE LENGTH OF THE. TRUSS. VVINDZONE III (18' X 14 I/2' AIAX111UTA SINGLE OPENING SIZE IN TRUSS SHEATHING) (I10 MPH)ALL EXPOSURES NOTES: ENGINEER APPROVAL: DAPIA APPROVAL• 1. 3/8* YIN. RATED SHEATHING FASTENED TO ROOF TRUSS WITH 7/16- X 1 GLE.(1eEDP AND 3' D.C. Al ALL RANNUR0GUE RaUM APPROVED BY IN MAY 1 a e INC. fEDEMLMANUFi MREOROME OMTRUCTION AND SAFETY STANDARDS o JACOBSEN HOMES INESE NOTICE: SPEanunONs DRAWN BY: R.R. DATE 4-27-98 REV. lEiiER: ■ AND T1RAwacs ARE ORIGINAL PROPRIETARY, AND CONFIOENRAL DRAWING TITLE: „ P.O. Box 368 MATERIALS OF JACOBSEN MANUFACTURING INC. 41CN MATERIALS ARE PRONGED TO 1HE TRUSS SHEATHING SAFETY HARBOR, FLORIDA 26-11 34F95 PHONE (B13) 726-1138 RE-ar RR'FF-C REPOM AND MUST BE KEP1 COIInWN11AL AND -gCJM ROM OIHM. DRAWING NUMBER: AD—HR-0001 12 £i Z000-HH-OV MW MA jWTK ON 7elea=1M Grit -sat (its) 3N0ll 7[31191N 9MM A J911 w mew am NOl ll�# m S69K WRIOM *WMrVH ALL AV CMVR HMA UK We lY 30 "H MONiH �inm � A fwmm :3n it 9WlYMo muoouoo ar MUM -mm , , 90-ZO-90 3Lva d U :xe rwvao �" WWO� VDU=ma SaI� 0H NaSUoovr SGHVGWLS W:lVS UNV NO117NNLSNO:) IMUH YiNNA31:11NVU Imaid 'ON' gooz,90 unr POSTASg ��J I Nx A9 (13A021ddd :lrnoxM VMWC oul 'uLgisquou3 ?, 9'£ZZ - O'EZZ -18-0 'Jd '01NO A3a sm .txa1-twAmiteousxolf 'm dm and Etna ami d m s 'NM 3M QL BU ON UM NY= MR StSDd OHM o3MH SIMMIS 3 M IOM M M! 31L M WE AM UM MYN '1 '1 10SON NOLIISOd do-13S NI J008 039NIH NOLLISOd ONIddIHS NI J008 039NIH -M wxM37wvAMJi A x ma gnu 9NLm3LM iwav IM i{ NM 31a1 ON wilmm Hm 1mlvRiL9A.4 No1L73; Ax am Lin 9 WMW dR-13 M MML60d SMS 'IIV12[Q dOOZI QaDKIH HINGED ROOF DETAIL UNDERLAYIIENT TO BE CLUED Y MIN. \\ ON BOTH SEC11ONS OF HINGE ROOF. FOR WIND ZONES 2 AND 3. RAISE EXTENDED SHINGLE AND UNDERIA11AIENT AND AND A MIN. 4 I1r YMDTH OF ROOFING CEMENT TO TOP OF LAST SHINGLE ROW ON FIXED ROOF SECTION, (THIS IS TO BE DONE BEFORE RAISINGHIN`GED ROOF SECTION.) ATTACH 2 X 6 X 8' BLOCK BEHIND 2 X 6 — OVERHANG FASCIA BOARDS AND SECURE VATH 3-18 X 3' WOOD SCI US EACH SIDE OF GAP. i 11 I` - NOTES: I. BRACE RAISED ROOF SEW N DE RAISED P0910 BEFORE 50 ANG HINGED KING POSTS NIO POSITIOIL APPROVED BY Revised Nov 30,2006 rl INC. FEDERAL W W UFAMNED HOME CONSTRUCTION AND SAFEW STANDARDS VANOZONE 11 (110 MPH) ALL EXPOSURES John C. DoO&A PA. K2 Enoneaft U>Ic. NOTICE: o"Im Br. DATE REV. am— JACOBSEN HOMES ram w6T1GwaAHDWAW=ARE D.T. 10-02-06 CRONAL wRr. AM a�nvi DRANN6 17M . /� PA eox 36B Y/1 mm °F &%coop" un "AMND HINGED ROOF DETAIL f—� Na 9101 Ulm" Ali rID"= TO me SAFETY HARBOR. FLORDA 3093 KOW AN W= IOPNO AND YST K DRAIM KAISER: PHONE '(e13) 726-1135 aTn Dow ww" no s0atl:1 am ums. AD—HR-0003 14 SHINGLE AND UNDERLAYMENT APPLICATION ON HINGED SECTION INSTALL ON SITE 15j FELT WITH A 6' MIN. OVERLAP ONTO MAIN ROOF CEMENTED WITH ROOF TAR AND SECURED PER NOTE #2 CONTINUE 15# FELT TO ROOF PEAK ONE-PIECE SHINGLE UNDERLAYMENT . 1 o' .... .......... .'.'.'..'...'.'..'.. .'.' 2' MIN. OVERLAP (TYP.)................. El.. ...... ................. ' 6' MIN. TAR AS SHOWN .(APPLIED ON SITE) SEE NOTE #3: ....... s ............. . . 3. MR ...'.'. .'. SEE DETAIL 'A' � Z U 4 , I SECURE FlRST ROW OF SHINGLE TO BE INSTALLED ON SITE WITH-6 STAPLES (1' X 3/4' X 16 GA OR ROOFING NAILS) PER SHINGLE MANUFACTURER'S INSTRUCTIONS AND CONTINUE TO PEAK. REMOVE THE ONE PIECE SHINGLE UNDERLAYMENT IN THE GAP (HINGE SECTION IN DOWN POSITION) BEFORE LIFTING THE HINGED SECTION OF THE ROOF TO ITS FINAL POSITION AND BEFORE INSTALLING THE 15j FELT AND SHINGLES. DETAIL A NOTES: 1. CEMENTING OF 15i FELT IS NOT REQUIRED W ANY AREA EXCEPT WHERE 'NOTED. 2. FASTENING OF 15# FELT IS NOT REQUIRED. (FASTENERS APKIED JUST TO HOLD FELT IN PLACE UNTIL SHINGLES ARE INSTALLED.) - . 0 3. EXTEND THE FIRST LAYER OF ON SITE 15E FELT ONTO THE FIXED ROOF A MIN. OF 6' AND UNDER THE LAST COURSE OF FACTORY INSTALLED SHINGLES IF NEEDED TO MAINTAIN THE 6' MIN. OVERLAP ONTO THE FIXED ROOF. 4. INCLUDED IN THE HINGED ROOF ADDENDUM ARE DETAILS AD—HR-0001 (WITH SPECIFIC END PANEL LAYOUT), AD—HR-0002, AD—HR-0003, AND AD—HR-0004. WINDZONE III (110 MPH) ALL EXPOSURES PROVED BY r 1lSF-p I I ►� INC. MANUFACTURED HOME C110N AND SAFETY STN'WARUS N017CL DRAWN BY. DATE Kv. MTIM JACOBSEN HOMES 1� IM MID MArr� � M.T. s-2o-o3 was JADOe�lAM CNFBDM DRAWING TITLE SHINGLE AND UNDERLAYMENT P.O. BOX 368 sac S,ol wIm,us ARE PROVW 1011E APPLICATION ON HINGED SECTION SAFM HARBOR, 26�1a4sgs FOR Nu PHONE ()726-i3ancolm,Ra � raaz AD-HR-0005 15 PEAK INSTALLATION DETAILS SECURE ROOF PEAK ASSEMBLIES TO — HINGED RAFTER WITH #8 X 4' SCREWS, 6.1/2.6 O.C. MAX DECKING ON RIDGE BLOCK ASSEMBLIES FASTENED WITH (6) 7/ 16" X II1 1/2" X 16 GA. STAPLES INTO EACH 15' O.C. RAFTER "AND 3 1 /2" O.C. MAX. INTO 2 X 4 RAIL (TYPICAL BOTH SIDES) NDS01 NOTES: ' I. SEE AD—HR-0007 FOR NSTALLATION OF UNDERIAYMENT AND SHNGLES. SEE AD—HR-0002 FOR ASSEMBLY DETAILS. CALM CRC - 167.01 - 167.02 -a�4�o4� John 0. uoe Teri, P.E -9Z Engi wring, Iric ALL 1MNDZONES ALL EXPOSURES 20 PSF ROOF 10 PSF D.L DADA X"DVAL — APPROVED BY INRevised Oun 09,2006 P71NC. FEDEFLIL M/MIIF1CiUREO MOMS CONSIAULlr �aO LFEIt A1nDl,NO5 JACOBSEN HOMES Nonce: r+csc sDcac�uno": iuo DaAre.es gat ��ar. O.A. 06-06-06 "�• ����^ FFJP Oiao"M, PWCPRZVMlr, AM COFF�F Iv& wmapa or aemsm ~Acnwww DRAWING pill: A Ka eox 3sa PEAK INSTALLATION DETAILS SAFEPHONE (OR; FLORIDA26-� 695 EK Sm Maroons ARE PRDVEM A r[ rcm sFOrDnn� � DRAWING ►xn R lvr C MDM^ SWO AD—HR-0006 16 SHINGLE/UNDERLAYMENT INSTALLATION SITE INSTALLED SHINGLES (USING THE 6 FASTENER METHOD) AND CAP INSTALLED PER MANUFACTURERS INSTALLATION j NsTRucnoNs. INSTALL FIRST LAYER OF 151 FELT TO ROOF NTH A V MIN. WIDTH OF ROOF CEMENT AT EACH END TO ROOF DECK AND/OR E)OSTING FELT AS SHOWN. TOP COURSES) OF SHINGLES TO OVERLAP PEAK AS SHOWN. SHINGLE INSTALLATION SEE OTHER DETAILS FOR 91 INSTALLED ROOF PEAK UNDERLAYMENT INSTALLATION INSTALL TOP LAZIER OF 151 FELT TO ROOF MITN A 6' MIN. MIRTH OF ROOF CEMENT AT EACH END TO ROOF DECK AND/OR EXISTING FELT AS SHOWN. BY . AUG 0 # 20 INC. NOTICE DRAVN BY: OATS: REV. LETIER: JACOBSEN HOMES Twst sE� s NO GRA.wS ARE M.T. 7-28-04 MWAL NiDPWI MT. AIO WF UNUAL DRAWL TIRE:min _ ,. YATF9" OF ULS ARE YOVM TO K SHAIGLE/UPOERLAYMENT INSTALLATION P.O. Box 36e rac a,al rAt�Ats ARE proMD®ro lE SAFETY HARBOR. FLORIDA 34695 R[C AMI ►Qt !font RiPW NO rust K DRAIIYIG NUMBER: PHONE (727) 726-1138 IVT OMMI'ua NO gCIET ttlot ODM AD—HR-0007 ADDENDUM TYP. SHIP -!LOOSE PLUMBING SUPPORT FASTEN TO FLOOR FRAMING MEMBER W/ STAPLE OR HAL NDIHG STRAP %AW. PED' AROUND PIPE AND FASTENED TO FLOOR FRAMING. OF NOT LESS THAN 1/4' PER FOOT MUST BE MANTANED TOWARD THE ITLET WOE INS CRADE CAN NOT BE ACHIEVED, NOT LESS 1HAN 1/8' r MAY BE USED Wig A rM SIZE CLEANOUT IS INSTALLED AT TW UPPER END. OF DRAIN PIPING 1. PIPE CLEANER AND GLUE SHALL ALSO BE BY THE MANUFACTURER FOR PLUMBING Cl 2. 48" O.C. MAX. SUPPORT SPACING. PIA APPROVAL; INC. JACOBSEN HOMES I' uc%5K1y0V MSIW MA"CSAM. M Dun er. R.R. CATS 7-17-97 REV LEr1Flt: [Milo CNIGIAt. PRdx[rAar. A►m cailDtRvl oRABrFc 1111E: mP.O. BOX 368 �Awaws PLUMBING SUPPORT SAFETY HARBOR. FLORIDA 34695 i¢�,� WW PJ NO III( PHONE (813) 726-1138 ' an caroomu wo sarr Ran caws "xHc Hur>3EA AD—PL-0001 18 NOTES: OPEN PORCH RAILING(S). IT IS THE RESPONSIBILITY OF THE SET-UP CONTRACTOR OR GENERAL CONTRACTOR ON SITE TO INSURE THAT THE RAILING(S) INSTALLED OR TO BE INSTALLED MEET ALL CODES IN EFFECT AT TIME OF HOME INSTALLATION. PPROVED BY W* I � INC. JACOBSEN HOMES NOTTcN:A THESE sPEa�cAnoes AND oaAwHcs ARE UT: M.T. unit:�v. 3-30-05 �I��^: WONAL, PROPBETARY, AND Cal MDAL DRAWING TITLE: P.O. BOX 368 MATMALS of JACOBSEN TAWACRWAG tNC SUCH YAT AALS ARE PROVW TO ME OPEN PARCH RAILING S SAFETY HARBOR. FLORIDA 34695 REOPM FOR S°= PI1RPM AND MI BE DRAWING NUMBER; PHONE (727) 726-1138 IIEPT CWmTK Am SEW FROM oms. AD-PO—W01 19 ON SITE PITCHED ROOF DETAILS IMPORTANT NOTICE THE ON SITE; PITCHED ROOF INSTALLATION (INCLUDING SHINGLES AND CAP) MUST BE COMPLETED WITHIN 60 DAYS OF DELIVERY TO THE HOME SITE. FOR ATTACHMENT OF ALL VENTING (INCLUDES 12 EXHAUST & ROOF), SOLAR TUBES AND PLUMBING 4 1 — VENTS SEE AD—PR-7007 & 7009. MAX. ROOF SLOPE FOR ROOF DECKING DETAILS SEE AD—PR-7004. FOR ATTACHMENT OF PITCHED RAFTER TO TRIPLE WIDE SEE / ` \ \ FOR ROOFING DETAILS SEE AD—PR-7002 SEE AD—PR-7008 SHIP THIS SEC. LOOSE (SITE INSTALLED) )-� --- — — — — — — ----�� FOR OVERHANGS SEE AD—PR-7003. FACTORYINSTALLED )FTERS (CENTER ENON REMOVE ALL FACTORY INSTALLED — POLYVINYL BEFORE INSTALLING THE ON SITE PITCHED ROOF RAFTERS — FOR ROOF VENTING BOTH FACTORY J AND ON SITE SEE AD—PR-7005 & 7006 SECTION OF TRIPLE WIDE TYPI -\L TRIPLE WIDE HOME REF. PG. IW-07-0011 WITP [31TE INSTALLED PITCHED FOR FASTENING C AI ER SECTION RAFTERS NOTES: APPROVAL APPROVED BY 000 rRevised Oct 25,2007 NC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS _ JACOBSEN HOMES LHESE�SPECIFICA AND DRA,IM ARE O�� OrO.A. un1E 10-24-07 REVLer>ER. P.O. BOX 368 DRIGIN MAID IL, PROPRIETARY. AND eONRCEN— ALS OF JACOM MANUFACTURING DRAWING TITLE: ON SITE PITCHED ROOF DETAILS $IT AM ®APFUSAFETY HARBOR. FLORIDA M95 PHONE (727) 726-1138 KEPT C�ONFlOEHTI& FOUR �W= FTERIAS W AM WI ST BE AND SECRET IRON OTHERS ORAYANG NUMBER: AD—PR-7001 20 ROOF. TO ROOF ATTACHMENT SECURE SITE INSTALLED ROOF DECKING SITE INSTALLED 7/16- MIN. ROOF WITH 7/16- X 1 1/2- X 16 GA. STAPLES DECKING SECURED WITH 7/16' X 1 1/2' (12) EACH SIDE OF MARRIAGE LINE TO X 16 GA. STAPLES, 2' O.C. WAX. 10 EACH 16' O.C. RAFTER. EACH 16' O.C. RAFTER. SEE DETAIL 'A' SEE 1401E 11 11' MIN. SITE INSTALLED DECKING 04i•BLAP FACTORY INSTALLED ROOF DECKING SITE INSTALLED RAFTER TO f ALIGN WITH FACTORY INSTALLED RAFTER BELOW. iop-- SEE NOTE /2 BE RIDGE BEAMS 18' MIN. EE NOTE 14) lk IDECKING N CROSS-SECTION REF. PG. RC-07-0044 FACTORY INSTALLED RAFTER (CENTER SECTION) YRNOZONV O ALL EXPOSURES (110 MPH) ZO P5F ROOF 10 PSF D.L NDS01 ""' "'"''y C-FS3 - 88.01 NOTES: ENOM APPROVAL DAM AMOVA I. SECURE EACH 16' O.C. RAFTER TO RAIL BELOW KITH 2-/10 X 4 1/2' SCREWS AT EACH RAFTER END. SITE APPROVED BY INSTALLED PITCHED RAFTER TO ALIGN WITH FACTORY INSTALLED RAFTER. (EA. SCREW TO HAVE 1 1/4' PENETRATION WIN.) Z ATTACH MATE LIE RAFTER RAILS (OR RIDGE BEAMS) WITH Jun 09,2006 110 X 4 1/2' SCREWS 9' O.C. MAX. SPACING. h Q,N PlC 3, SEE AD-FA-0020 FOR GAP TREATMENT BEIVUN SECTIONS. John C. iwde3n. f! &:. 1*0t§u Nam, Ac1u iN f • K2 Engkmerillg. Inc. CommuCTIONAND SKEWSTANOANOS NOSIC[: DRAIN BT: OAIF: IQY IETIEIt JACOBSEN HOMES = � ORAIMMM O.A. 06-02-06 P.O. BOX 3" WIENIAl3 OF .MC !XN UAKWACftmo WARM Altf: /� W6 MAN rA10M AM MWED 10 H ROOF TO ROOF ATTACHMENT H SAFETY HARBOR. FLORA 34695 XCPW Ftl SCOM FJOW w1 ow Et DRAW HLUKA PHONE (727) 726-1138 - tm ewlemL so zmf na owt 'AD-PR-7002 21 2 X 6 OUILOOKER 19' O.C. MAX. BETWEEN OUILOOKERS --+/ Qc .. --- 2 X '6 OVERHANG FASCIA THIS TRUSS NSTALO ON SITE BOTTOM CHORD 1600 DOUBLED END ZONE RAFTERS TYP. 16. O.C. F Woo * . 0 A/qr'iz 2 X 4 NAILING BLOCK (INSTALLED ON SITE) MIN. (3) .131 X 3' NAILS FROM NAILING BLOCK INTO RIM PLATE OF ADJACENT SECTION OF UNIT. AND . MIN. (3) .131- X 3' NAILS FASTENING FASCIA INTO END OF NAILING BLOCK 2 X 6 OUTLOOKER 19' O.C. MAX. BETWEEN OUI DOKERS OUTLOOKERS SHOWN ARE 2 x 6 SPF /3 FLAT SEE CHART FOR FASTENING OUTLOOKER TO TOP CHORD -MULTIPLE TRUSSES FASTENED TOGETHER W/MIN..131' X 3! NAILS OR MIN. 7/16' X 2 1/2' X 15 GA. STAPLES 16' O.C. MA)OMUM INTO TOP do BOTTOM CHORDS ONLY. 2 X 6 FASCIA FASTENED TO OUILOOKFR � �'- 2 X 6 OVERHANG FASCIA END ZONE ASSEMBLY NOTE: W/MIN. (5) 7/16- X 2 1/2- X 15 GA. SHIPPED ASSEMBLED FOR SITE INSTALLATION DUROOKERS TO BE MCM TO EAfJ1 STAPLES OR MIN. (3) .131 X- 3- NABS TM OF THE DOUBLE TRUSSES UXA70 (TYPICAL AT ALL CENTER BRACES) IN 11E DMZONE PER FASIOER auRT. SINGLE 1RUSS ONLY REOro OUTSWE OF b FT. AREA ..SS MAY W PLACED ON Elm S4 NDS01 1. ALL TRUSSES LOCATED WITHIN 36' OF THE END OF SECTION TO BE DOUBLED. 2. SEE OTHER DETAILS FOR TYPICAL ROOF FRAMING. 3. EACH TRUSS IN END ZONE AREAS ARE REQUIRED FASTENED PER AD-PR-7002. JACOBSEN HOMES P.O. BOX 368 LWO SAFETY HARBOR. FLORIDA 34695 PHONE (727) 726-1138 THE ROO TV. OUTLOOKER FASTENING: FASTENERS QUAM. FiNEIRATXME .131 PD NAIL 5 1 1/f 15 Gk • STAPLE B 1' SCREW 2 1' (INCL Tip) OUILOOIFR FASTENERS MAY BE IMAM VaNulum TT7 FROM TOP CHORD DON F PEIMAAON ALL EXPOSURES D (110 MPH) 20 PSF ROOF 10 PSF D.L. REF. CUCS. C-RC-197.01-197.02 BE �v 177-1(08 1 John C. DoedA-n, *Rk- {C2 Engina0Tfing; Inc. Nomom DRAWN BY: SPECFIGI'I M AID W VINCS ARE &. PROPRETARY. AND CO:DEM.K DRAWING MM- DF �ANUFACItlralc END ZONE RA CN YATDi" ARE Pwmm m DIE R FOR SPEDFIC NAxm AID w K DRAWING NUMBER x1mu I ARD mo FROM cum APPROVED BY ON 14 Feb 05,2008 INC. FEDERAL MANUFACTURED MOPE C DNSTRIICnON AND SAFETY STANDARDS O.A. DATE 1-29-08• REv. tET1ER FTER OVERHANG ASSEMBLY A AD-PR-7003 ON SITE PITCHED ROOF DECKING INSTALLATION TYP. ROOF FRAMING 16" ON CENTER MIN. — I TRIPLE WIDE CENTER SECTION PEAK \ _ SITE MALUED DECKING CN PITCHED NO BLOCKING REQUIRED TRUSS SECTION do REMAIt�ER OF /� I AT CONTINUOUS PANEL 80TN 00TSDE SECTIONS (2 FULL / ROWS OF SHEATHING) SEAMS BETWEEN TRUSSES SEE OTHER DETAILS TO SECURE SITE INSTALLED PITCHED TRUSSES MIN. WIDTH PER SHEATHING REQUIREMENT APA RATED ROOF DECKING (OR EQUAL) TRIPLE WIDE MARRIAGE LINE MANIIF. INSTALLED DECKING TO HERE r= I m ONNDZONE 91 ALL EXPOSURES (110 MPH) 20 PSF ROOF 10 PSF D.L NOTES: UfjlK x &'MVAU UAYUY AFYNUYAL' 1. 1/8" MAXIMUM GAP AND 1/16- MINIMUM GAP BETWEEN DECKING PERPENDICULAR AND PARALLEL TO TRUSSES. APPROVED BY *IoON P 2. ROOF DECKING MATERIAL TO BE 7/16- APA RATED ROOF (24/0 W Revised SPAN RATED) DECKING (EQUAL OR BETTER). John C. �%0��=�. RM Oct 29,2007 3. OTHER TRIPLE WIDE SECTION (NOT SHOWN) WILL BE THE K2F—T1C9*T4�A(Li;-lRc;- INC. SAME DECKING PATTERN. FEDERAL KMUFACfURED HOME 4. FASTEN DECKING TO ROOF FRAMING WITH 7/16 X 1 1 /2- X 15 CONSTRUCTION AND SAFETY STANDARDS GA. STAPLES AT 3- O/C EDGES AND REM JACOBSEN HOMES mm me w OWN B� O.A. 10-24-07 `�` `�` a mum aR»wm. me aonOE m DRAW llllfic P.O. BOX 368 YATE511A1S DF dAC SM IlWACRIMIC Nt SUCH MAM49S AW � TD � ON SITE PITCHED ROOF DECKING INST. SAFETY HARBOR. FLORIDA 34585 I A 4EIM FCR VIM NNW NO lust IS DRAwNG Mid AO—PR-7004 PHONE (727) 726-1138 WT CINIFE NML AIO sm ira OHM 23 11 TYP, 50 SQ. IN. ROOF VENTS (SEE TAD-PR-7006 FOR QUANTITIES) TYP. 100 SO. IN. CUTOUTS FOR - i VENTILATION OF ROOF SECTION (SEE AD-PR-7006 FOR QUANTITIES) 'LIT CENTER SECTION OF ROOF INSTALLED AT MANUFACTURER TYP. ROOF INSULATION -� / CEILING PANEL:: CENTER SECTION (FLAT TRUSS) MARRIAGE WALLS MARRIAGE WALLS FLAT CENTER SECTION NOTES: SITE INSTALLED CENTER SECTION OF ROOF DAPIA APPROVED BY � Revised Oct 25,2007 IPINC. MANUFACTURED HOME CTION AND SAFETY STANDARDS NOTICE: DRAWN BY. DATE: Icty, �I TUC O.A. 10-24-07 JACO BS EN HOMES THESE SPIEVIPICAMS AND DRAWINGS ARE ORKWAI, PROPRIETARY, AND CONHDFlNTIAL DRAWING TITLE: ! MATERIALS OF JACOBSE N MANUFACTURING _ P.O. BOX 368 Wt SUCH MATERIALS ARE PROVSED TO THE SITE INSTALLED PITCHED ROOF VENTS SAFETY HARBOR. FLORIDA 34695 RE"T FOR SPEOM PUNS AND WIIST BE DRAWING NUMBER: A PHONE (727) 726-1138 CM COfhD01114 AND SECRET AM MIfRS. AD-PR-7005 24 ROOF VENTING 3 W MARRIAGE HALLS I I TV TOO SO. 6L CUTOUTS FOR 161tATIOM OF Roo► SECTION �- (SEE owl TOR REOURFuENTS) 100 SQ. 1N. CUTOUT VENT HOLES N REQUIRED 1N FLAT ROOF SECT10 (1607 x SECTION LEIIGT)t CUTOUT 1101E5: 0 To TS'-r 1 15'-6' 10 V-3' 2 31-r 10 W -Hr 3 46'-IIF TO 6 -6 4 62-6 TO -0 5 I I. MARRIAGE WALLS FLAT CENTER SECTION OF ROOF FACTORY INSTALLED I I MARRIAGE WALLS / LOW VENT LOW VENT 950 S0. IN, VENTS REQUIRED `3 HIGH VENT IN SITE INSTALLED TRUSS SECTION O 1-1 —-----------`- \-CENTER LINE OF CENTER SECTION (w) = scum 1 Dcvt NDR 101k l0 101E 10 m -T ROEt we 31'-r 10 4V-W UK 4w-w 10 6r_r 1 EA SIM it A EEi 3 2 EA SOE -0 I mmm IU URioLgmi KRIS •-r R-r •m4 --- TVP. 50 SO. IN.ROOF VENTS +-,I LOW VENT (SEE CHART FOR REOUREMENTS) LOW VENT r / MARRIAGE WALLS SITE INSTALLED CENTER SECTION OF ROOF. 3 2 W 3 z W I I I ( I 1w PROVED BY JUN 14lip ? INC. AL MANUFACTURED HOME 'MMION AND SAFETY STANDARDS - NOTICE ORAWN BY: DATE: REV. LETTER: JACOBSEN HOMES m3EsKancAmGAwWma mm R.R. 01-22-04 OIE WAL PROPR(IARf, me CQww1ft DRAWNG TITLE: T- P.O. eox 36s 111pOKS Or JACOM YnMR'ACTUA•IG ROOF VENTING 61G SOOT MARRA$ MK PROW= 10 WE SAFETY HARBOR FLORIDA 34695 ROPOR FOR 9'M PIRPOKS RID NO K DRAWK NUMBER: PHONE (727) 726-1138 PVT w nmzk MnmX1not o1ERs AD-PR-7006 tR I I. MARRIAGE WALLS FLAT CENTER SECTION OF ROOF FACTORY INSTALLED I I MARRIAGE WALLS / LOW VENT LOW VENT 950 S0. IN, VENTS REQUIRED `3 HIGH VENT IN SITE INSTALLED TRUSS SECTION O 1-1 —-----------`- \-CENTER LINE OF CENTER SECTION (w) = scum 1 Dcvt NDR 101k l0 101E 10 m -T ROEt we 31'-r 10 4V-W UK 4w-w 10 6r_r 1 EA SIM it A EEi 3 2 EA SOE -0 I mmm IU URioLgmi KRIS •-r R-r •m4 --- TVP. 50 SO. IN.ROOF VENTS +-,I LOW VENT (SEE CHART FOR REOUREMENTS) LOW VENT r / MARRIAGE WALLS SITE INSTALLED CENTER SECTION OF ROOF. 3 2 W 3 z W I I I ( I 1w PROVED BY JUN 14lip ? INC. AL MANUFACTURED HOME 'MMION AND SAFETY STANDARDS - NOTICE ORAWN BY: DATE: REV. LETTER: JACOBSEN HOMES m3EsKancAmGAwWma mm R.R. 01-22-04 OIE WAL PROPR(IARf, me CQww1ft DRAWNG TITLE: T- P.O. eox 36s 111pOKS Or JACOM YnMR'ACTUA•IG ROOF VENTING 61G SOOT MARRA$ MK PROW= 10 WE SAFETY HARBOR FLORIDA 34695 ROPOR FOR 9'M PIRPOKS RID NO K DRAWK NUMBER: PHONE (727) 726-1138 PVT w nmzk MnmX1not o1ERs AD-PR-7006 tR -0 I mmm IU URioLgmi KRIS •-r R-r •m4 --- TVP. 50 SO. IN.ROOF VENTS +-,I LOW VENT (SEE CHART FOR REOUREMENTS) LOW VENT r / MARRIAGE WALLS SITE INSTALLED CENTER SECTION OF ROOF. 3 2 W 3 z W I I I ( I 1w PROVED BY JUN 14lip ? INC. AL MANUFACTURED HOME 'MMION AND SAFETY STANDARDS - NOTICE ORAWN BY: DATE: REV. LETTER: JACOBSEN HOMES m3EsKancAmGAwWma mm R.R. 01-22-04 OIE WAL PROPR(IARf, me CQww1ft DRAWNG TITLE: T- P.O. eox 36s 111pOKS Or JACOM YnMR'ACTUA•IG ROOF VENTING 61G SOOT MARRA$ MK PROW= 10 WE SAFETY HARBOR FLORIDA 34695 ROPOR FOR 9'M PIRPOKS RID NO K DRAWK NUMBER: PHONE (727) 726-1138 PVT w nmzk MnmX1not o1ERs AD-PR-7006 tR PITCHED ROOF EXTENDED VENTS SITE INSTALLED VENT CAP OR SOLAR TUBE VENT CAf (OR SOLAR SITE INSTALLED FLEX DUCT SITE INSTALLED VENT CAP (SEE DETAIL 'A) SITE INSTALLED CENTER \ / , SECTION OF ROOF �- EXTEND FLEX DUCT 3' ABOVE RAFTER SHEATHING FLEX DUCT (FACTORY INSTALLED) FACTORY INSTALLED SHEATHING — FACTORY INSTALLED CENTER EXTEND PIPE 3' ABOVE SHEATHING SECTION OF (ROOF PLUMBING VENT (FACTORY INSTALLED) I LTYP. CONNECTION TO VENT FAN, SOLAR TUBE, OR EXTEND TO RANGE HOOD MARRIAGE WALLS :XHAUST DUCT SPLIT 1ND FASTENED TO RO OF )ECKING OR BACKER MTH MIN. 4— 8D NAIL N LIEU OF FASTENING )UCT TO VENT CAP. SITE INSTALLED FLEX DUCT ` `SHEET METAL SCREW FLEX DUCT (FACTORY INSTALLED) NOTE: EXHAUST DUCT (FLEX DUCT OR RIGID) SECURED WITH 1 SHEET METAL SCREW MINIMUM AND ALUMINUM TAPE TO SEAL AROUND DUCT AFTER SCREW IS IN PLACE. DETAIL 'A' CEILING PANEL MARRIAGE WALLS SITE INSTALLED PLUMBING VENT PIPE (EXTEND 3- ABOVE ROOF) (SEE DETAIL 'B') PLUMBING VENT ROOF FLASHING (SITE INSTALLED) VENT PIPE (SITE INSTALLED) COUPLER m-10�(SITE INSTALLED) VENT PIPE 0-o-(FACTORY INSTALLED) DETAIL ' B' NOTES: +CONSTRIDN OVAL: 1. FOR VENTS NOT SHOWN INSTALL PER MANUFACTURERS SPE ICFICATIONS. 2. SEE OTHER DETAILS FOR ROOF FLASHING INSTALLATION. BYI EXHAUST HOLE GUT U T MAYOF DBE RUNING. THROUGH EITHER A SOUARE OR ROUNDJUN 4. RANGE AND BATH/AIR DUALITY FLEX DUCTS TO BE SPLICED WITH ALUMINUM TAPE AS SHOWN IN THE DETAIL ABOVE. S. SECURE SITE INSTALLED PLUMBING VENT PIPE INTO COUPLER WITH IN . APPROVED GLUE. D HOME ETY STANDARDS JACOBSEN HOMES NO1Ce DRAWN BY: DATE REV. LETTER: ,,,ESE muTloMs AM oRAwws ARE R.R. 01-23-04 �FRWKTART. AM CDf MTIAL DRAWING TITLE N P.O. Box 368 w °lUtaS A " 1AM1fAC10 ImE PITCHED ROOF EXTENDED VENTS NC, sua wuTeAts ARE rRavoEo ro n[ SAFETY HARBOR. FLORIDA 34695 RFMW FOR 9'ECIF R/A M AM WEI RE DRAWING IA11BER: J PHONE (727) 726-1138 _IVT ammuL A MIXT FRa own AD—PR-7007 SITE INSTALLED SHINGLE AND UNDERLAYMENT FIELD INSTALLED 15{ FAT MIN. INSTALLED OVER THE FACTORY INSTALLED UKHRLAriENT W11H A 6' MIN. OVERLAP AND A MIN. 6' WIDTH OF ROOF CEMENT. 151 FELT TO HAVE A 6' MIN. OVERLAP 151 FELT ALSO CEMENTED WITH A 6' WIDTH AROUND AND A MIN. 6' WIDTH OF ROOF CEMENT ALL PENETRATIONS OF THE UNDERLAYMENT AND THIS ALSO APPLIES TO ENDLAP SEAMS. PERIMETER OF ROOF. I C FIELD INSTALLED RM SNEATHING (TYP.) b� � y, { 6' WIDTH OF ROOF CEMENT WHEN 1 ( OPTIONAL 15 j FELT IS INSTALLED. r1 I r I r I r I r I — I IN OPTIONAL LINER OF 15/ FELT y� .J — -I QI r� 1 ONE-PIECE SHINQE UNOERLJ11YF11T ROOF SHFA NG MR) THIS ROW OF SHINGLES TO BE FIELD INSTALLED AFTER THE,UNDERLAYMENT HAS BEEN INSTALLED. THE LAST COURSE OF FACTORY INSTALLED SHINGLES TO LEAVE A MINIMUM OF 6' FROM THE TOP OF THE SHINGLE TO THE EDGE OF THE FACTORY INSTALLED DECKNG FOR UNDERLAYMENT OVER LAP OF 6' MINIMUM. t /z. yr TO TO 3' 3' a FASTENING DETAIL WANDZONE IU (110 MPH) ALL EXPOSURES NOTES: BMW APPROVAL: DAPIA APPROVAL 1. CEMENTING OF OPTIONAL 15/ FELT IS NOT REQUIRED IN ANY AREA APPROVED BY EXCEPT WHERE NOTED. Revised Oct 29,2007 2. FASTENING OF OPTIONAL 15/ FELT IS NOT REQUIRED. (FASTENERS APPLIED � INC. ARE JUST TO HOLD FELTIN PLACE UNTIL SHINGLES ARE INSTALLED.) .I�I'Zg UU:'��f1. 3. SHINGLES INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS 2 Engiric-10"19, (no` 7CTIDN MANUFACTURED noSTANDARDS ONLY WHEN SPECIFIC APPLICATIONS ARE NOT COVERED. JACOBSEN HOMES 1m �► AND I�1N= AN `"m'� �i O.A. """ 10-24-07 "`" ""`� ORION 1L PROPBE NX AN OIfIDEMIUL MAMN&S OF JACOM UNWAMURM DRATANG VM- NT A P.O. BOX 368 pt onYA1F]IIAS AK PRm m 10 >HE SITE INSTALL D SHINGLE AND UNDEitLAYM SAFETY HARBOR. FLORIDA 3*95 NOW I;y15Pf1l1t: PM= NO W EE DRAWING NUMOM PHONE (913) 726-1138 IGP1 triil0D m me SEfAET RIM own AD-PR-7008 TYPICAL ��FLASHING INSTALLATION "7OFING TAR UNDER 11LING FLANGE AT .L FASTENERS ROOFING TAR APPLIED OVER FASTENERS AND UNDER ALL SHINGLES OVERLAPPING THE ROOF FLASHING. OPTIONAL SHINGLES MAY BE APPLIED TO P COVER ANY ROOF VENT FLANGE BY SECURING THE SHINGLE TO THE FLANGE AREA WITH ROOF— ING MASTIC (TAR), p TYPICAL SHINGLE ROOF TYPICAL FIELD INSTALLED RAFTER ADS' X 1' MINIMUM ROOFING NAILS OR .113' X 1- MINIMUM NAILS MAY SE USED IN LIEU OF STAPLES FOR FASTENING FLASHING TO ROOF. OPT. SOLAR TUBE INSTALLATION SOLAR TUBE DOME. WITH NAILER FLANGE. SECURED TO ROOF. ON UNDERLAYMENT. AND TOP OF FLI UNDER SHINGLES, YNTH BOTTOM I FLANGE OVER SHINGLES (BOTTOM MAY BE COVER WITH SHINGLE TA SECURED NTH AN APPROVED CA TUBE SUPPLIED BY SOLAR TUBE MAN. 1. ROOF FLANGE FASTENED TO SHINGLE ROOF WITH MIN. I X 1' X 16 GA. STAPLES 6' O.C. (SHINGLES APPLIED UNDER LOWER END OF FLANGE). XDAPIA APPROVAL• A ROVED BY .jtj% 1 0 i r1l INC. AL MANUFACTURED HOME RUCTION AND SAFETY STANDARDS p NOnCF. DRAWN BY: DATL REV. LETTER JACOBSEN HOMES XSE sK�TOG AW WAS AK M. T. 02-04-04 ElAwlOi WAL rRorl IMT• ADO CII�E111b11 DRAWING TITLE: „ P.O. BOX 368 �A1LmeLs Cr utoeS., ROW01 CTIIIiX TIP. FLASHING INSTALLATION Nc SWI w1IRu115 ARL PROvOD) TO hE SAFETY HARBOR, FLORIDA 34695 IEGMI FOR SPEOTC PUF t %S NO MST 1E DRAB TR1118ER PHONE (813) 726-1138 art CDfM k NO SEMI rM DICK AD—PR-7009 28 ADDENDUM GENERAL 'NO TES , / TIE- DO I NS NOTES: I FRAME TIE -DOWNS SHALL BE INSTALLED TO PROPERLY SECURE THE HONE. 2. VERTICAL TIE -DOWNS ARE REQUIRED IN ADDITION TO THE FRAME TIE -DOWNS 3 VERTICAL TIES MAY BE SECURED TO THE SANE GROUND ANCHOR AS THE FRAME TIE -DOWNS 'AHF11 A DOUBLE HEADED ANCHOR IS USED AND IS CAPABLE OF RESISTING THE COMBINED LOADING. ViEN ANCHORS ARE NOT INSTALLED AT THE ANGLE(S) SPECIFIED IN THE TABLE(S), A STABILIZER PLATE MUST BE:NSTALI_T IN ACCORDANCE WITH THE ANCHOR MANUFACTURER'S INSTRUCTIONS. 4. FRAME TIE -DOWNS AND ANCHORS ARE NOT SUPPLIED BY JACOBSEN HOMES (TO BE SUPPLIED BY OTHERS). 5 VERTICAL ME STRAPS MAY BE SUPPLIED BY JACOBSEN HOMES OR ANCHOR BRACKET MAY BE INSTALLED BY JACOBSEN HONES FOR ATTACHMENT OF VERTICAL LIE STRAPS, IN EITHER CASE ALL ANCHORS AND END TREATMENTS ARE TO BE SUPPLIED BY OTHERS. 6. ALL GROUND ANCHORS AND FRAME TIES SHALL BE INSTALLED PER THE MANUFACTURER'S DISTALLAVON INSTRUCTIONS. GROUND ANCHORS AND FRAME TIES ARE NOT TO EXTEND BEYOND THE EXTERIOR WALL OF THE UNIT. 7. STEEL ANCHORING EQUIPMENT EXPOSED TO THE WEATHER SHALL BE PROTECTED WITH A MIN. OF 0.30 OZ. OF ZINC COATING PER SQUARE FOOT OF STEEL 8. DESIGN BASED ON 95 1/2' I -BEAM SPACING AND A MAXIMUM SIDEWALL HEIGHT OF 8'-0* (82" I -BEAM SPACING IS ACCEPTABLE FOR 10' WIDE SECTIONS OF MULTI -WIDE UNITS W/ W SIDEW'AL.L HEIGHT ONLY). 9. LONGITUDINAL TIES SHALL BE INSTALLED ON THE INSIDE OF EACH.I-BEAM AT THE CROSS -MEMBER LOCATIONS OR PER ALTERNATE DETAILS IN ACCORDANCE WITH THE SPACING TABLES AND NOTES 4, 6, 7 tIND 16. 10. FRAME TIE -DOWNS SHALL BE 'WRAPPED' AROUND THE MAIN I -BEAM (AS SHOWN ON If. CROSS-SECTION DETAILS) AND SHALL COME OFF THE TOP FLANGE OF THE I -BEAM WITH AN APPROVED BUCKLE OR LOOP. 11. ANCHORS SHOULD BE CERTIFIED FOR THESE CONDITIONS BY A PROFESSIONAL ENGINEER ARCHITECT OR A NA10ALLY RECOGNIZED TESTING LABORATORY AS TO THEIR RESISTANCE BASED ON THE INSTALLED ANGLE OF THE DIAGONAL ME AND/OR VERTICAL LOADING AND ANGLE OF ANCHOR INSTALLATION AND TYPE OF SOIL IN WHICH K ANCHOR IS TO BE INSTALLED. 12 GROUND ANCHORS SHOULD BE EMBEDDED BELOW THE FROST LINE AND BE AT LEAST 12' ABOVE THE WATER TABLE. 13. GROUND ANCHORS SHOULD BE INSTALLED TO THEIR FULL DEPTH, AND STABILIZER PLATES SHOULD BE INSTALLED TO PROVIDE ADDED RESISTANCE TO OVERTURNING OR SLIDING FORCES 14. 'ANCHORING EQUIPMENT SHOULD BE BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT TO RESIST THESE SPECIFIED FORCES IN ACCORDANCE WITH TESTING PROCEDURES IN ASTM STANDARD SPECIFICATION D3593-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL AND SEALS 15. ALL (;ROUND ANCHORS TO BE RATED FOR LOAD LISTED IN TABLES, TIMES 1.5 SAFETY FACTOR OR AN ULTIMATE LOAD OF 47251 (31501 DESIGN LOAD), WHICHEVER IS GREATER. VALUES IN THE TABLES ARE DESIGN LOAD VALUES. 16. A MAXIMUM OF TWO LONGITUDINAL TIE -DOWN STRAPS MAY BE INSTALLED AT A SINGLE CROSS -MEMBER LOCATION. IF MORE THAN TWO LONGITUDINAL TIE -DOWNS ARE REWIRED (SEE APPROPRIATE SPACING TABLES) ADDITIONAL CROSS - MEMBERS MUST BE USED FOR ATTACHMENT OF STRAP(S) (OR SEE OTHER DETAILS FOR ALTERNATE STRAP ATTACHMENT). 17. LONGITUDINAL TIE -DOWN STRAP(S) MAY BE INSTALLED AT AN ANGLE NOT PERPENDICULAR TO THE CROSS -MEMBER TO WHICH IT IS ATTACHED (SEE NOTE 16) IF REQUIRED TO MISS PIER LOCATIONS OR OTHER OBSTRUCTION(S). 18. ALL FIGURES (DETAILS) SHOWN IN THIS SECTION ARE TYPICALS ONLY. REFER TO THE APPROPRIATE TABLES FOR THE REMO NUMBER, SPACING AND/OR SPECS OF SPECIFIC TIE -DOWNS AND ANCHORS REQUIRED. 19. SEE OTHER DETAILS IN THE SET-UP MANUAL AND ADDENDUM FOR BLOCK94G REQUIREMENTS. ALL BLOCK:NG DETAILS CONTAINED WITHIN THIS MANUAL ARE APPLICABLE FOR ALL ZONES AND ALL EXPOSURES NOTES: THESE NOTES AND DETAILS ARE APPLICABLE FOR WIND ZONE II AND/OR WIND ZONE III. THEY ARE ALSO APPLICABLE TO BOTH EXPOSURE 'C' AND EXPOSURE V. SEE APPROPRIATE TABLES FOR SPECIFIC INFORMATION ON EACH. �,.....���i��� DAPIA O',%STE ROVED BY Q ENE 8703571 " •UTA'' Mac .W 1 5 IM INC. JACOBSEN HOMES NOTICE TTM;;i@T�''- DATE: REV. LETTER: TNESE SPE011CATIONS AND NNAVMCS AM C.L.Y. 5-19-95 \, ORIGINAL. PROPRIETARY. AND CONTIODRIAL DRAWNG 71ILi n P.O. BOX 368 MATERIALS OF JACOBSEN YANUFACIURINC TD-GENERAL NOTES H SAFETY HARBOR. FLORIDA 34695 OK SUW MATERIALS ARE PROUCED TO THE REGENT FOR SPEC= WOOS NO MUST DE DRAINING NUMSM PHONE (813) 726-1138 KEPT COWDDIft AIO SECRET TRoM orrus. AD-TD-0001 29 ADDENDUM NORMAL TIE —DOWN SPACING TABLES ZONE II&III/EXP. C & D �\, v LONGITUDINAL TIE -DOWN SPACING TABLE MIN. FLOOR WIDTH WIND ZONE 11 WIND ZONE III MR. oTY. EA. END OF EA. SECTION ANCHOR ANGLE YIN. 0 YIN. OTY. EA. END (f EA. SECTION ANCHOR ANGLE U.N. 0 20'-0' 2 36' 2 45' 24'-0' 2 46' 2 60' 25'-4' 2 50' 3 38' 26'-8' 2 54' 3 41' VERTICAL TIE-IIDOWN / FRAME TIE -DOWN SPACING TABLE MIN. FLOOR WIDTH MAX. EAVE OVERHANG WIND ZONE n WIND ZONE III SPACING DBL. DBL. HEAD ANCHOR ANGLE SPACING DBL. HEAD LOAD ANCHOR ANGLE 20'-0' 12' 8'-0' 31501 40'-50' 6'-8' 31501 40'-50' 24'-O' -12' 8'-0' 3150# 40'-50' 6'-8' 3150# 40'-50' 25-4' 12' 8'-0' 31501 40'-50' 6'-8' 31501 40'-50' 26'-8' 12' 8'-0' 31501 40'-50' 6'-8' 31501 40'-50' of �S 1 o U I� p LONGITUDINAL TIE —DOWN SPACING TABLE MIN. FLOOR WDIH WIND ZONE 11 WIND ZONE III EA. ENDD k EA SECTION ANGLER ANGLE YIN. 0 YIN OTY. EA. END EA. SECTION ANCHOR ANGLE MIN. 0 20'-0' 2 50' 2 68' 24'-0' 2 70' 3 50' 25-4' 3 45' 3 60' 26'-8' 3 45' 3 60' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. FLOOR WIDTH MAX. EAVE OVERHANG N WIND ZONE II WIND ZONE NF SPACING DEL HEAD LEAD ANCHOR ANGLE SPACING M HEAD LOAD ANCHOR ANGLE 20'-0' 12' 5-4' 31501 40'-45' 4'-0' 3150g 40'-50' 24'-0' 12' 1 5'4 315011 40'-50' 4'-0 3150# 40'-50' 25-4' 12' -4' 31501 40'-50' 4'-0' 3150# 40'-50' 26'-8' 12' 54 1 315DI 40'-50'..,1a "I'lli A:-0' 1 3150# 1 40'-50' OTES:.. �^w^�t�5Na.. a✓U ,,� �M�� MrRVY/1L 1. SEE AD-TD-0001 FOR ADDITIONAL REQUIREMENTS. �O "lj Q�G`STE NO % PPROVED BYE z SEE AD-m-0011 FOR UAXPAUIA PIER HEIGHTS REQUIRED FOR THE LOADS = r ENEB M BUL TAATED ABOVE. _ 5 •' 9��OF INC - .��,e�'••., . pIA1 . '•�� .� �' A17(ML WN1fK111�N01E as,� no sArm surovloe 66 JACOBSEN HOMES NOTJCV THESE SPEC7F1CAnaNADMMNGS ARE k+� C.L.Y. HATE:' 5-30-95 R' P.O. BOX 368 CRONA4 PROPRIETARY. AND CONFlDENTIAL MATERIALS OE JACOBSEN UMAACMNG INC. SUCH WATERKS ARE PRO40 10 THE DRAWING TITLE NORM. SPACING TABLES O ARBOR. FLORIDA 34695 SAFETYPHONE FOPfNT E�SK IC PJNS<5� OTHEM DRAWING NUMBER: AD-TD-0010 30 ADDENDUM S'6 11 ALTERNATE TIE —DOWN SPACING TABLES v O ZONE II & III/W. C LONGITUDINAL TIE —DOWN SPACING TABLE MK V ND ZONE 0 W ZONE 0 FLOOR WL V. u 00 ff ANm Away lK on om OF mcm 0 EA. SBCiQM �. 9 FA � sLTaall ML e 23'-4' 2 54' 3 40' �O 24W 2 54' 3 40' 254 2 60' 3 44' 26'-8' 3. 38' 3 a 3 4T 4 41' (SEE NOTE 14 FOR ANCHOR MGLES) VERTICAL TIE —DOWN /FRAME TIE —DOWN SPACING TABLE YIN. MAX. WND ZONE II WIND ZONE If sPAaI1s A ANIUR MOLE . SPAM LOAD ANm Alm MDlH OVERRf1�ANG '29 4' 12' 54 31501 W-45' S'-4' 3150 f 33'-a 24'-T 12' 6-4' 31501 40'-45' 64 31501 35'-40' 25-4' 12' 514 31501 40'-45' 5-4' 3150f . 35-40' 26'-8' 12' 54 31501 40=45 6--4' 31M 35'-40' 12' 54 31501 a-45' 5'-4' 3154 35-9 (SEE NOTE 14 FOR ANCHOR ANW) CsoDo Fp o00 ,,......, ��•��,�� E IV .��� •� ' No 45484 % ivy PC �0 •• m` REF. CALC. ®A�F'•• : 1� 1 p p'� `?o�� C-TD - 215.01 - 215.20 �� is `••..... f9 e 'ONAIL NOTES: EiLtiIm APPROVAL: DW APPROVAL: 1. SIX 0-M-OM FOR ADD11113M REQUtRE]OM APPROVED BY 2. SEE AD-M-01.1 FOR YAXUN PER HEIGHTS WAMS FOR THE I = TABW.ATED AM 16,2009 N1A-IN TE-mm DEM ON in PAGEAPPILOI M TO DOUBLE 013 ONLY. C 4. on Moo MQE SHONLt IN THE CHART ABOVE CANNOT BE ACNE% . FEDERAL CONSTKANURUCTION SAFERED HOSE CONSTRUCf10N AND s+tfETr STANDARDS AND DLSTALLED M APPRDVfiD STAIRM PLACE. JACOBSEN HOMES UM 94nWIM M MOM AK M.T. 06-04-09 DRn�rlc �4LTERNATE SPAONG TABLES P.D. Box See tllaWL FFOFIE W W CMFMD ltAL MAXIMS Or.' WWAOMM — SAFETY HARBOR, FLORIDA 34695 PHONE (613) 726-1138 W. alai MAIMMs ARE FF&M TO IM ItfF w Fat arc Ftlli bES AID IdZ K IT CNIENK M MKT FROM OOHS DRABEIG NU11EER99 AD-1T�0010.1 31 ADDENDUM TIE- DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS YAX PER AD-TD-0010 TABLE PER AD-10-0010 TAW PER AD-M-0010 TAKE PER AD-M-0010 TABLE I'm *-TD-0010 TARE YAX FIGURE 1.0 SEE FIGURE 20 FOR ALTERNATE TR 401111 IMOD TYPICAL CROSS SECTION I I III SNOWING TIEDOWNS J "� �00R'77 ' SEE NOTE 5 FOR . YAWL HDHGHT :-- ANW ANGLE ANCHOR ANGLE— 4 IR FIGURE 1.1 SEE FIGURE 5.0 FOR ALTERNATE TIE -DON YE S �.(1���D V NOTES: ENGINEER`. AE• •(jOCO���!' A V C�B i ,.�` p'�`.•'G�STFq ' F2 �. 1. SEE AD-M-0010 FOR SPACING TABLEScoo '• ISEE AD-TD-0010 FOR QUANETY OF LONG1TWAL TIE -DOWN STRAPSIREQURED. Q No. 1 1 20 3. SEE OTHER DETAILS FOR BLOCIONG (PIER) OUANTITY AND 01HM REOUREYENTS. _ ENE8703571 INC,4. SEE AD-TD-0001 FOR ADDITIONAL REQUREYENTS ' 5. ZONE 2/EXPOSIJRE 'C': 6W YAXMUY HEIGHT ' '� •: S If, • ku ZONE 2/EX OWRE V: 44' YAXWUY HEIGHT ZONE 3/EXPOSURE V: 40' YAXMUD Y HEIGHT �•A, •' C7\REF. CALCS: �`. ZONE 3/EXPOMRE V; 36" YAXMUY HEIGHT �ii,�tss+�0• . •• • �� ��� I N017C� OlN�p11 DATE: IV. LETTER: JACOBSEN HOMES THESE LETTER - WE AND DRAWINGS ARE C.L.Y. 3-27-95 CRIGINAL. PROPRIETARY. AND CONFIDENTIAL DRAWING TITLE WITERNILS OF JACOBSEN UANUFACIIRNG FIGURES 1.0 AND 1.1 P.O. BOX 368 W- bTlCN NATEWAIS ARE PRONGED TO THE SAFETY HARBOR, FLORIDA 34695 RECPlW FCR SUM PDA4M AND VM 1E DRAWING NUUBER: PHONE (613) 726-1138 WT CONFWU& AM SECRET FROM OTNOM AD-TD-0011 i ADDENDUM RECOMMENDED TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE —DOWN SPACINGS FIGURE 1.0 TYPICAL CROSS SECTION II MOWING ' 11EDOWNS TTP. RNR TV. men ma (SEE ROLE 0) Mon MME (a ROLE P) ' FIGURE 1.1 (DESIGN BW ON 951/f i—EAM cEx>ERRs AND se' HN SIMS) NOTES: 1. SEE AD-1D-0010.1 FOR SPACMIG TABLES. 2. SEE AD-7O-00.1 FOR QUM" OF I NOE = X-CON STRAPS REWIRED. 3 SEE OTHER DETAILS FOR •MMING (PIER) QUAN 11Y AND OTHER REQUIRENE M 4. SEE AD-10-0001 FOR ADDIRONAL REIXIMEIM 5. ZONE 2AXPONRE 'C': 67' MAWN HDGIR ZONE 3AVORK 'C'.' 56• "MIUM HEIGHT 6. *EH ANCHOR ANGLE SHOW) ON AD-1D-0010.1 CANNOT BE MOM, INSTALL AN APPROVED STARLZER PLATE. JACOBSEN HOMES Nouca 1= WOMMOS AM WA1M ARE MMM.. PFtaPFeUM AM WffM t X DRAM Err DRAWNO 11 MAMAIS OF JAC IM NAF01fAC 010 RHHARBOR, P.O. BOX 368 OC SUCH Mhlff B AK PROYM TO IM DRAWN If SAFETY FLORIDA 34695 R27W FOR SFEOiC KWW AM WST IS PHONE(813) 726-1138 MY C016MW L Alm MU FROM 003131s �01%f NAI 'e:°°°0 o�Al�aaaa�9� SEE ROLE 5 M YA101L9 MIT APPROVED BY ONOOP ,hm 16INC. ,2009 FEDERALA CONSTRImom An &AFTY s ANDAS C-TD- 215.01 - 215.20 M.T. DATE 06-04-09 FIGURES 1.0 AND 1.1 AD—TD-0011.1 33 ADDENDUM gas I� Stz NORTIE-DOWN SPACING TABLES ZONEI & III/EXP. & D LONGITUDINAL TIE —DOWN SPACING TABLE (�1 MIN. WIND ZONE II WIND ZONE III Ug,v FLOOR WIDTH MIN. OTY. [A. END OF EA. SECTION ANCHOR ANGLE MIN. 8 MIN. OTY. EA. END OF EA. SECHCN ANCHOR ANGLE MIN. 0 12'-0' 2 43' 2 55' 13'-4' 2 50' 2 68' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III FLOOR WIDTH SAVE OVERHANG SPACING DEL HEAD LOAD ANCHOR ANGLE SPACING DEL HEAD LOAD ANCHOR ANGLE 12'-0' 6' 8'-0, 31501 40'-50' 6'-8' 31501 40'-50' 13'-4' 6' 5-0' 31501 40'-50' 6'-8' 3150# 40'-50' LONGITUDINAL TIE —DOWN SPACING TABLE 0 MIN. WIND ZONE it WIND ZONE III . ^� v FLOOR N UK OTY. EA. END OF EA SECTION ANCHOR ANGLE MIN. 0 UK OTT. EA. END OF EA SECTION ANCHOR ANGLE MIN. 0 12 '-O' 2 64' 3 47' O� p �j 12'-0* 3 31' 4 33' 13'-4' 3 42' 3 1 55' 13'-4' 4 30' 4 38' VERTICAL TIE—DOV TN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. ' WIND ZONE II WIND ZONE III SPACING DEL HEAD LOAD ANCHOR ANGLE SPACING DBL HEAD LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 12'-0* 6' 5-4' 31501 40'-45' 4'-0' 31509 40'-50' 13'-4' 6' 5'-4' 31501 40'-50' 4'-0* 31501 40'-50' NOTES I I. SEE AD-ID-000l FOR ADDITIONAL REQUIREMENTS ' 2. SEE AD-TD-DO13 FOR WXIUU4 PIER HEIGHTS REQUIRED FOR THE:LOADSL, TABULATED ABOVE.ENE8703571 ENO;EERV O nt� �.�� Q�\ '�' \S T OFQ , �� �: •�,�NCH RFo F2 ,�, DAPIA APPROVAL APPROVED BY �-�.-- JUN ' 5 3. MAX. EAVE OVERHANG REFERS TO OVERHANG AT SIDEWALL NOT FRIONT OR REAR. 4. ABOVE TABLES APPLY TO 160' FLOOR OR 144' FLOOR WIDTHS WITH 95 1/2' I -BEAM SPACING 96' MAJOYUN SIDEWALL HHEICHT AND 6' MAXIM U� SIDE OVERHANG (6- Ori W4C MAX. EACH SIDE OF UNIT). * �: STAT'= F y 4, �i /F`� �/v� 1 QN, •�� �4 F N, I N C �L7FAhrwJK1U®N]E coaipno,NoscmWAONM JACOBSEN HOMES NOTICE: �t/Itl 11 �mEsE SPE011CA1,01S AND DRAWINGS Aw IIfILwe ' c.�.Y. DATE: - 5—_30-95 REV. LETTER: P.O. BOX 368 SAFETY HARBOR34695 PHONE (,,,)FLORIDAa726-1138 PRONAL. PKPFJE7ARY. AND CONFIDENTIAL YAIFRIALS OF IACOBSEN UkffAClMNG W_ SJCH NAXAkS ARE PROVIDED TO THE KOPEK FOR S EOX RPPOSES AND M 51 BE PPT C"MI- L NO Mau FROM omm n /H, DRAWING TITLE: NORM. SPACING TABLES DRAW.NG NUMBER: AD-TD-0012 34 TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS TYPICAL CROSS SECTION SHOWING TIEDOWNS ADDENDUM TIE -DOWN SYSTEM FIGURE 1.2 SEE FEGURE 20 FOR eI.TEREEATE TEE—DOW RMID ANGLE ANGLE FIGURE 1.3 SEE FEGURB 7.0 FOR 1L WITE I E—DDIN 1lMD SEE NDTE 5 FOR MAXII01 HEIGHT NOTES: talfiNEE`R,,(�1[Qbb/l////� DAPIA APPROVAL: C• 1. SEE AD-TD-0012 FOR SPACING TABLES AND NOTES 2. SEE AD-TD-0012 FOR OUANTY OF LONGIIUDIAL TIE -DOWN STRAPS REQUIRED. �•�`�����. •��FO��''% •�G\STEq� APPROVED BY N0. n '•_ 000orp 3. SEE OT HER DETAIS FOR BLOCIONG (PIER) oUANnw AND OTHER REOLARFJAE M 4 4. SEE AD-ID-0001 FOR ADDITIONAL REOUIREMHNTS. - EN 870357 -5. ZONE 2/E)(POSLIRE 'C•: 30• MAXWUM HEIGHTIN - INC, - ZONE 2/EXPOSURE •0: 48• MAXIMUM HEIGHT ZONE 3/EXPOSURE •C : 28' MAXNAUY HEIGHT• OF [�p, _ ( �.t�•'•//`% ZONE 3/EXPOSURE V: W MAXIMUM HEIGHT ty�. ��• • •N••L� JACOBSEN HOMES N017C)'��/ n+EsE sKcmnM AND DRAw�Illm"II If o" C.L.Y. DATE: 5-19-95 REV. LETTER: DRAININGnnE FIGURES 1.2 AND 1.3 P.O. BOX 368 ORIMA A „ SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 W. SLtH MAIEAWS ARE PRDVV D TO THE RECFDIT FOR 9WX P WOKS AND VM lE WT COIFEDI 4l DID SIM FROM OMM DRAWING NUMBER: AD-TD-0013 35 ADDENDUM ALTERNATE TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION WNEIc TIF-DOWN SPACINGS SEE FIGURES 1.1 FIGURE 2.0 1.3 FOR TYP. CROSS -SECTIONS) NOTES F;1 PAOVAL••. //i/ �� DARA APPROVAL BYE 1. SEE AD-TD-OD10 FOR SPACING TABLES REWIRED. = �: F`�' No.F� '• ENE8703571 APPROVED 2. SEE AD-TD-0010 FOR QUA►aTY OF LONGITUNAL TIE-DOW STRAPS REQUIREMENTS. ; 1 3. SEE OTHER DETAILS FOR BLOMNG (PIER) QUANTITY AND OTHER _ �• - 4. SEE AD-M-0001 FOR ADDITIONAL REQUIREMENTS INC. KbE �I PT, /O JACOBSEN HOMES NOTICE: THESE sPEonunoNs AND DRAVANGS ARE GRIGiNW PROPRIETARY, AND CONrMT1AL DRAWN BY: C.L.Y. DATE: 5-19-95 REV. LETTER: / \ DRAWING TITLE: P.O. BOX 368 SAFETY HARBOR. FLORIDA 34695 PHONE (013) 726-1138 MA1T k OF JAC08S H MANUFACTURING IMG SUCH MATEMS APE PRGNDED TO THE RECIPDIT FOR SPECIIC PJMM AND WST BE iVPT COtdWnk kc SEcto EROY oT1ERS. FIGURE 2.0 /H\ DRAWING NUMBER AD-TD-00I4 36 ADDENDUM ALTERNATE TIE -DOWN SYSTEM(S) ALTERNATE LONGITUDINAL TIE -DOWN INSTALLATION METHODS SIDE MEW OF MAIN FRAME TIE-pO1VN STRAP SEE OTHER oETALS FOR TIE-OGWN STRAP SPECIFICATIONS. APPROVED ANCHOR L�c'.DED TO MAIN I -BEAM (SEE OTTER OETAiLS SEE AD-7D-0200 FOR FOR NELOW) 70 BE INSTAl1EC RADIUS CUP DETALS AT W FACTORY. (REOWRED TITS LOCATION). (MIN. 31501 WOWNG (DES13N) LOAD AND 47251 ULTIMATE LOAD.) 00 GROUND ANCHOR SEE OTHER DETAILS FOR SIZE, wAXLE AND OTHER INSTALLATION NOTES FIG URE 2.1 SOLID HEADER (CROSWELBER) FRONT VIEW3• X 3/4' (= 1/2) . MUST BE LOCATED CUT INTO HEADER W1MUS S• OF CAN FOR STRAP ATTAChidENL VATHIN i OF MA (FACTORY CUT) Pam SEE AD-ID-02D0 FQ.3 I SEE F{A�IUS CLIP DETALSR /RADILS CLIP DETAILS I ! (REQUIRED THIS LOCATIONS I (REOUTO THIS LOCATON). 5• MAx TIE-DOTtN STRAP SEE OTHER GETAILS SIDE M FOR TIE -DOWN STRAP SPECIFICATIONS GROUND ANCHOR' 0 SEE OTHER DETAILS FOR SIZE, ° ANGLE AND OTHER UiSTALLATION NG-5. FIG URE 2.2 NOTES: _ Uy &PPFOVAE::\'1• DAPrA A.—WOVAL: 1. SEE AD-TU-0010 FOR SPACING TABLES + • + tic I - - _ -' 2. SEE AD-TD-0010 FOR OUANITY V LONCIIUDIAL TIE-DOvm STRAFS RCOU:RED. J. SEE OTHER DETAILS FOR BLOCKING (PER) QUANRTY AND OTTER REGLGREMENTS. 4. SEE AD-TD-ODOI FOR ADDITIONAL REWREMENTS. ��i •' 0rf .;"• ,,111lilt 1E1 ANOIOR BRACIET AND TIE-DO44 DEVICES ARE CERTIFIED BY OTHERS K077C4 CRAWN BY. DA L. REV. LITER; JACOBSEN HOMES T� SKCMA.O/S AND CRAI< M ME C.L.Y. B-13-55 WGNAL PI1:°WMy. AM3 COMWMAL DRAIMNG A TITLE: P.O. BOX 368 VAT S OF iACOM YAMFACTLI0K3 FIGURES 2.1 & 2.2 !IL SUOI MAF., tas A;[ M VZED 10 IK SAFETY HARBOR. FLORIDA 34695 a1st71T rat rEax napo56 AAD wsT t DRAWING NUMBER PHONE (813) 726-1130 AL''I cnhnxNix ma s otff new Dauer AD—TD-0015 '47 I LONGITUDIN�I'AL STRAP ATTACHMENT CATOR BEAM CLAMP, MANUFACURED BY TIE -DOWN ENGINEERING, PART g 59011 (SEE MANUFACTURERS INSTRUCTIONS FOR COMPLETE INSTALLATION DETAILS) TYPICAL LONG17UDWAL ANCHOR STRAP (FlELD INSTALLED) NOTES:: DAPIA APPROVAL 1. SEE OTHER DETAILS FOR STRAP PROTECTION AT ALL SHARP CORNERS A P ROVED BY 2. ALL -STRAPS TO BE TYPE 1, FINISH B, GRADE I STEEL STRAPPING, 1 1/4" N1DE AND 0.035 INCHES IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL JUN 1 5 • m ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D 3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL, AND SEALS. I N C. JFREDEMANUFACTURED HOME CON RUCTION AND SAFEfYSTANDARDS NOTICE: DRAWN BY. DATE: REV. LETTER: •JACOBSEN BIOMES TNEg SPEOFICATIONS AND DRAWINS ARE M.T. 6-12-01 GRIGIM P�OPRIETART, AND CONFIDENTIAL DRAWING TITLE: MATERIALS OF JACOBSEN MANUFACTURINC P.O. BOX 368' UC SUCH 4ATEIMS ARE PRONDED 10 THE LONGITUDINAL STRAP ATTACHMENT SAFETY HARBOR, FLORIDA 34695 RECIAENT FOR SWIC PURPOSES AND MUST BE DRAWING NUMBER: AQ-TD-0016. PHONE (727) 726-1136 HEFT CUMPIIRO& AM SECrXl TROY OTHERS 38 ADDENDUM gas SOT OFFSET UNIT TIE -DOWN SPACING TABLES ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN. SPACING TABLE (+� MIN. WIND ZONE II WIND ZONE III YIN• oTY. ANCHOR URL OTY. ANCHOR FLOOR WIDTH EA. END OF ANGLE Ell END OF ANGLE O EA, SECTION IR1L B FA SECTION ImL B 10'-0' 2 44' 2 56' 12'-0' 2 57' 3 42' 13'-4' 3 38' 3 50' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPAONG D' HFAD LOAD ANCHOR ANGLE SPACING Del. HEAD Low ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 10'-0' 12* 4'-0' 31501 40'-50' 4'-0. 31501 40'-50' 12'-0" 12" 4'-0' 3DO01 40'-50' 4'-0. 31501 40'-50' 13'-4' 12' 5-3' 31501 40'-50' 4'-0' 30001 40'-50' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III UK OTY. ANCHOR UK OTY. ANCHOR FLOOR WIDTH Ell END GF EA.OF ANGLE •�� EA SECTION 11DH. a m EA. SECTION 1111lL . e 10'-0' 2 64' 3 46' 12'-0' 3 50' 3 68' 13'-4' 3 58' 4 48' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING -TABLE MIN. MAX. WIND ZONE II YANO ZONE III SPAONC DBL HEAD Low ANCHOR ANGLE SPACING DBE. HEAD LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 10'-0' 12' 4'-0' 31501 40'-50' 2'-8' 31501 40'-50' 12'-0* 12' 4'-0' 31001 40'-50' 2'-8' 31501 40'-50' 13'-4" 12" 4'-0' 30651 40'-50' 2'-8' 3000j 40'-50' NOTES: ENa` ►� -�avAI�Q�, A VAMTD BY 1. OFFSET SECTION %ITH THE MARRIAGE LINE WALL EXTENDING BEYOND THE ENDWALL OF Q� • G\S T *F� �� REVISED THE ADJACENT SECTION MUST BE TIED DOTN AT THE MARRIAGE LINE IN ACCORDANCE VA Di THE TABLES ABOVE THE SIDEWALL SIDE AND THE ADJACENT SECTION(S) ARE Toi SEP 0 9 1 BE TIED DOWN IN ACCORDANCE WITH THE NORMAL SPACING TABLES (AD-TD-0010). . '2. ADDITIONAL . :. '�' `• C• NC. SEE AD-M-0001 FOR REQUIREMENTS. �, 3. SEE AD-m-0021 FOR MAXIMUM PIER HEIGHT REWIRED FOR THE LOADS TABULATED �'•!�9�j(g6r:'• .� FED ��i F�+''• RAL MANUFACTURED HOME STAND ABOVE. ..IAh'••C����� COIISTRUCTION AND SAFETY JACOBSEN HOMES TONS AN: +,IRE nrcsE sPEanuTroNs AND DRAN'JICS ATtF I �\r R.R. DATE 8-27-96 REV. EfrTTR P.O. BOX 368 ORCINAL PROPPJCIARY. AND COINIDFNTML MATERIALS OF JACOBSEN MANUFACTURINC M AIRE PROVIDED B DRAWING TITLE: OFFSET SPACING TABLES SAFETY HARBOR. FLORIDA 34695 PHONE (813) 726-1138 AEOOPCNT RR SPEINC. rnc NnvOSESS NO WAl BE ►APT C&#`CEIOAI NO SECRET n= OTHERS DRAWING NUYDER AEI-TD-0020 39 OFFSET V TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SHOWING TIE -DOWN SPACINGS Y •^l DENDUM TIE -DOWN SYSTEM FIGURE 3.0 SEE FIGURE 4.1 FOR ALTERNATE TIK-DOWN WTHOD TYP. CROSS SECTION(S) SHOWING TIEDOWNS L SEE NOTE 5 FOR MAXIMUM HOW mm ME FIGURE 3.1 SO FIGURE 6.0 FOR ALTERNATE TIE -DOWN XMIOD ITABIES ON AD-TO-0020 itlZ d4I AFPLY TD THESE STANOM IAIUI-VIDE SEC➢OtS OF THE UNIT -SEE NOTE 1. AO-TD-0010.] TYP. RIAOR SYSTEM, TYP: CRoss-YE16ER ANDIOR ANGLE ANDIOR FIGURE 3.2 1I.114y ALTERNATB TIE -DORM IVETHOD NOTES: --� �� :r••.. � DAPIA APPROVAL 1. SEE AD--0020 FOR SPACING TABLES (OFFSET SECTION ONLY). �� �O`.'�G\ST�,S, ,t�,)'' Z. SEE AD—TDTD-0020 FOR OUANITY OF LONGITUDIAL TIE —DOWN STRAPS REOUIRED. No. �. •, APPROVED BY (OFFSET SECTION ONLY) __ ENE8703571 3. SEE OTHER DETAILS FOR BLOCIONG (PIER) QUANTITY AND OTHER REQUI TS. _ d` 4. SEE AD—TD—ODOI FOR ADDITIONAL REQU REMENTS ``` 7NrAINC, 5. ZONE 2/EXPOSURE C: 44NAXIMUY HEIGHT f''• /�L •� FEm =NOW ZONE 2/EXPOSURE 'D': 24' MAXIMUM HEIGHT (32" 0 24' WIDE MIN.)ZONE 3 i� �C�'•., . ...•. �\ `��� sw�ARpp ZONE 3/D=RE V: 32" MAXIMUM HEIGHT (44' 0 24' VADE MIN.) QNAI E�;�```� JAC O BS E N HOMES THESE sPEaFTcAnoNs ORIGINAL. PROPRIETARY. I NOMCK S AND AND DRAWINGS ARE AND CONFIDfNW DRAWN BY: C.L.Y. DATE 5-11-95 REV. LETTER DRAWING TITLE: ❑„P.O. box 368 MATERIALS OF INC. SUCH NATERIALS JACOBSEN MANUFAClMHG ARE PROVIDED TO THE FIG. 3.0, 3.1 & 3.2 A DRAWING NUMBER: SAFETY HARBOR, FLORIDA 34695 REO W FOR RM MOSS Am MIST BE PHONE (813) 726-1138 IFPT CKDENTIAL AND SECRET FROM OTHERS AD-TD-0021 40 ADDENDUM ALTERNATE OFFSET UNIT TIE-DOtitiN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SHOWING TIE-GOAy . SPACINGS FIGURE 4.0 SEE FIGURES 3.1 AND 3.2 FOR TYP. CROSS-SECTION ,,,,u,IrIITr►p, NOTES: Ov �i� OAPIA APPROVAL 1. SEE ADm-oo20 FOR SPAG" l; TABLES (OFFSET SECTION ONLY). � ; . �q� . F2•,i APPROVED BY Q� No. o . 2. SEE AD—TD—=O FOR OUANITY OF LON01WAL TIE—DONN STRAPS REOUIRED. (OFFSET SECTION ONLY) _ NE8703571 3. SEE OTHER DETAILS FOR BLOOC-4G (PIER) OUANIITY AND 01HER REOUIREIIENTS _ INC 4. SEE AD—TD-0001 FOR ADDITICCAL REOUIREYENTS T Q IVA_ 01 lk m JACOBSEN HOMES P.O. 90X 368IALS SAFETY HA.Rc_-R. FLORIDA 34695 PHONE (813) 726-1138 xsE SPE011C TW)USS NOnAW DRANNIX ARE OwNAL PROPIEETMY. AND C01110 nAL YAIMW OF ACOM MAN NACRMC �I MR 91CM � NO iT10b' K IVT COrF10 TK NO gain N,DN CUM �N,�, D,: C.L.Y. "" 5-11-95 '�'' "/'� / ` /A--►1 DRAINNO TITLE: FIGTHE. 4. ORAFaWO NUYBEk AD—TD-0022 ,; 411 Rq� I ADDENDUM R �1 C��gS ERR ALTERNATE UNIT TIE -DOWN SPACING TABLES 5 0 ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE �+1 MIN. WND ZONE II 1YIND ZONE III UK �1 FLOOR UIN. QTY. EA END OF ANCHOR ANGLE QTY. EA. END IT ANCHOR ANGLE , Y�DTIi EA. SCION MIN. 9 EA. SECTION WIN. 0 �O 20'-0' 2 36' 2 45' 24'-0' 2 46: 2 60' 25'-4' 2 50 2 67' 26'-8' 2 55' 3 30' VERTICAL TIE -DOWN l / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING 11 DEL HEAD ANCHOR ANCE SPADNG DEL HEAD LOAD ANCHOR ANGLE FLOOR EAVE 1MDTH OVERHANG LOAD 20'-0" 12' 4'-0' 36701 20' 4'-0* 39001 20' 24'-0' 12' 1 4'4 3700# 20' 4'-0* 3950# 20' 25-4' 12' 6'-8' 40001 1 15' 4'-0' 39501 22' 26'-8' 12' 6'-8' 3950 28' 4'-0" 3950# 22' LONGITUDINAL TIE -DOWN SPACING TABLE MIN WIND ZONE II WIND ZONE III FLOOR MIN. OTY. EA END ANCHOR ANGLE uuH OTY. EA. END OF ANCHOR WTH O EA SEcnoN unl a EA SECTION Mw e K O� 20'-0' 2 50' ' N/A N/A �j 24'-0' 2 70' N/A N/A 25'-4 3 42' N/A N/A 26'-8' N/A N/A N/A N/A VERTICAL TIE -DOWN FRAME TIE -DOWN SPACING TABLE MIN MAX WINCH ZONE II WIND ZONE III SPACING DEL HEAD SPACING DEL HEAD LOAD ANCHOR ANGLE FLOOR EAVE WIDTH OVERHANG LOAD 20'-0" 12' 4'-0' 46001 N6' N/A N/A N/A 24'-0' 12' 4'-0' 40001 N/A N/A N/A 25'-4' 12' 4'-0' 40001 N/A N/A N/A 26'-8' 12" 4'-0' 4000 , N/A N/A N/A NOTES: L�J1 Opt` DAPIA APPROVAL• .r • • ". 1. SEE AD-TD-0001 FOR ADDITIONAL REOUIREUENTS no 2 SEE AD-TD-0031 FOR MAXIMUM PER FiE1CHT REQUIRED FOR THE LOADS TABULATED ENE8703571 ': s - —•. ? ABOVE: .. .A. J. 20 N1DES -82' MAXIMUM I -BEAN SPACING ONLY. 4. 4' MAXIMUM INSET TO ANCHOR HEADS (SEE AD-TD-0031). / 67 �y '• /2 ( 7�. �'.-1el F . N�I�,• `� �.��� _.........-_.:.. nAlAl J AC O B S E N HOMES u /NTT No�Ec� THESE SPEaE1UTHXNs AND DRATM a ALE ,9Rf%w►E' : � C.L.Y. DATE 6-13-95 REV. LETTER: DRAWING ITLE: ALT. SPACING TABLES MONAL�PROPRQIART, AND CONIIDOIHAL MATENIALS OF JACOBSEN MAWFACARNG P.O. BOX 36B SAFETY HARBOR FLORIDA 34695 LNG SU04 NAMIALS ARE PRONDM TO THE RmPen rCR 91E= RFPW AND MST K m DRAWING NUMBER A0— TD-0O30 PH 726-1138 MT CWWTK AmD sEcFv FRDu OTIT 42 �.6 ADDENDUM ALTERNATE, TIE -DOWN SYSTEM(S) TYPICAL CROSS SECTION SHOWING TIEDOWNS SEE NOTE 4 FOR UW= HDGHT 4-. L FIGURE 5.0 SEE FIGURE Ll FOR RECOMIDED 710-DON MED IMPORTANT NOTICE: THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS THEN USING TITS TIE -DOWN. CONFIGURATION A SME CREST PRODUCTS MODEL 57SH (TYPE 21 AUGER ANCHOR = A DESIGN LOAD (TORIOAG IDAD) RATING OF 4,000 POUNDS AND AN ULTMATE LOAD RATING OF CODO POUNDS MUST BE USED. AN EQUIVf6ANT ARMOR MEETING THE ABOVE SPDMCATIONS MADE BY ANOTHER MANUFACTURER MAT BE USED IN LIEU OF THE ME COT PRODUCTS ANCHOR. NOTES: THE ALTERNATE BE—DOM METHODS SHOM ABOVE ARE ACCEPTABLE FOR USE N I. SEE AD—TD-0001 FOR ADOL110NA1 REOUIREYENTS ALL WIND ZOI.ES AND INB07H EXPOSURE 'C' AND EXPOSURE V. HOWEVER. BY 'OUTBOARD' INSTALLING 7HE FRAME TIE —DOWN STRAPS AT THE I —SEMI THE MAX 2 SEE OTHER DETAILS FOR BLOCIGNC (PIER) OUA14717Y AND OTHER REOUIRENENTS HEIGHT OFF THE GROUND IS GREATLY REDUCED. SEE OTHER DETAILS FOR THE 3. FOR FIGURE 5.0 SEE ALTERNATE TiE—DOWN SPACING TABLES (AD—TD-0030). RECOMMENDED YETHOOS FOR INSTALLING; FRAME TTE—DOTINS. 4. ZONE 2/0(POSURE 'C': 3X YA7CM:lY HEIGHT ENt�Hfot,AFPROVALLI.. '' DAPIA APPROVAL ZONE 2/EXPOSURE'D': 27- MAXLIPJM HEIGHT %% �N - NU HEIGHT```�O 'D': PLICATION No, 6;. •��i'i�� - ^ ZONE 3ZONE /EXPOSURE THIS IS NOT APPLICABLE. ,�1 ` JACOBSEN HOMES NOTICE `r'rr" THESE SPwnCATXrrs ' BY: C.L.Y. DATE 6-13-95 REV. LETTER: P.O. EOX 368 AND DRAVOM ARE DfiONAL. PROPRIETARY. Mu CONFIDfJInft UATMA S OF JACOMMUFACTO M UROI DRAWNG TITLE., FIG. 5.0 „ SAFETY HARBOR. FLORIDA 34695 or Ala MAXUS ARC PRDHD:D TO THE RLOVIT FOR SPECFX PJWM AM TAW RE DRAWNG NUMBER: PHONE (813) 726-1138 IvT 0WIDINTIAL AM moo n w 0Tfm AD-TD-0031 •43 ;,ADDENDUM CO ALT. OFFSET UNIT TIE -DOWN SPACING TABLES 6 QQ ZONE II & III/EYP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE MIN WIND ZONE II WIND ZONE III WIN.OTY. ANCHOR WIN.OTY. ANCHOR FLOOR IMDTH EA END OF ANGLE EA. END OFANGLE ��Q O EA SECTION YIN. A EA SECTION MIN. B 20'-0' N/A N/A N/A N/A 24'-0' 2 42' 2 53' 254 1 2 45' 2 58. 26'-8' 2 48' 3 370 - ING TABLE VERTICAL TIE-DOWNII / FRAME TIE DOWN SPAC MIN. MAX. WIND ZONE II WIND ZONE III SPACING � NERD V LOAD ANCHOR ANGLE SPACING HEAD LOAD ANCHOR ANGLE FLOOR WIDTH LAVE OVERHANG 20'-0' 12' N/A li N/A N/A N/A N/A N/A 24'-O' 12' 4'-0' �,4000j 20'-30' 4'-0' 4000# 20=-30' 254 12' 4'-0' 4000 j 20'-30' 4'-O' 4000# 20'-30' 26'-8' 12' 4'-0' 40001 20'-30' 1 -4'-0' 40001 25'-30' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III MIN. OTY. ANCHOR WIN. W. ANCHOR N FLOOR WIDTH EA. END ON EA. END ANGLE FA SEC110 WIN. DI. A IO EA SECTION YIN. 6 20'-0• N/A N/A N/A N/A 24'-0' 2 60, 3 45' �1 I 254 2 66' 3 48' I p 26'-8' 3 41' 3 52' VERTICAL TIE -DOWN FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DOIL HEAD LOAD ANCHOR ANGLE SPACING � HEAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 264 12' N/A N/A N/A N/A N/A N/A 24'-0' 12' 1 S-8' 4,000¢ 20'-30' 2'4 4000# 20'-30' 25'-4' 12' 4'-O' 4000J ZS!-30' S-2' 4000$ 1 W-30' 26'-8' 12' 4'-0' 4'000 j 25-30' S-2' 4000# 25'-30' NOTES: ENGINEER IfYVNIIN#fill,l� DAPIAAPPROVAL' IENDWALL C: ��c0''':,., PPROVED BY 1. OFFSET SECTION VAIN THE MARRIAGE LINE WALL EXTENI)m BEYOND THE of THE ADJACENT SECADN MUST BE TIED DOWN AT 7HE MARRIAGE LINE IN ACCORDANCE ,• `• �Q,.\STEM .C�2 :� ;Z�G ON WITH THE TABLES ABOVE THE SIDEWALL SAE AND THE ADJACENT SECTION(S) ARE TO BE TIED DOWN N ACCORDANCE WITH THE ALT. SPACING TABLES (AD-TD-O030). ? No. Eno,/ r .�1 1 'F A INC 2. SEE AO-1D-0001 FOR ADDITIONAL REOUFUENTS r .� = ar ` rt�, , : uFeuiort CW •-: v..•.. S�i1�SINCM1Od' 3. SEE AD-TT}-0033 FOR YAXDJUY PIER HEIGHT REOUIRED FOR THE LOADS TABULATEDABOVE. ,�^�y .AC (. , ��• ��. JACOBSEN HOMES NOTICE: '�i� is + THESE SIONS ANDDRAMNCS'�i�: AV • ���`�` C.L.Y. DATE: 5-30-95 REV. LETTER DRAVNG TIRE- ALT. SPACING TABLES P.O. BOX 368 OPoONAL; PROPRIETARY. AND CO16WRAL MATERIALS OF JACOM MANUFACNRING HARBOR. FLORIDA 34695 PHONE (8131 726-113a WC. IERIALSSAFETY gIPROWMED TO THE I�FOR SPECETC R�NP= APO OW K KEPT CONDDRPL LLD SECRET FROM OTHM DRAWNG NUMBER: AD-TD-0032 44 rOr IS NO SEE ��E + ADDENDUM 105 ►'" BURS gE4� 4°11�E �c�o ALTERNATE TIE -DOWN SYSTEM TYP. CROSS SECTION(S) SHOWING TIEDOWNS AKLE mu FIGURE 6.0 SEE FIGURE &I MR RECOTDIENDED TEE-DOTN METHOD SEE NOTE S FOR I AIO" HEIQ1r (TAMES ON AD-TO-M MINE APPLY TO THESE STANOMr01AILD-11E SECMIS OF THE UKT -SEE NOTE 1. AD- D-M] TYP. FLOOR SISTW 7 TIP. ANON>tE "I M1010R ANdE FIGURE 6.1 SEE FIGURE 32 FOR RDODNDMM TZ-DOTN KE HOD IMPORTANT NOTICE: THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS THEN USING THIS TIE-DOIIN CONFIGURATION A STYLE CREST PRODUCTS YODEL 57SH (TYPE 2)), AUGER ANCHOR UITH A DESIGN 1DAD (TORiDNG IAAD) RAIN OF 4,000 POUNDS AND AN ULML47E IDAD RATING OF 6,000 POUNDS MUST BE USED. AN EQU(YH,ANT ANCHOR WTING THE ABOVE SPECIFICATIONS MADE BY ANOTHER MANUFACTURER MAY BE USED IN LIEU OF THE STYLE CREST PRODUCTS ANCHOR. NOTES: THE ALTERNATE TE-DOWN METHODS SHOWN ABOVE ARE ACCEPTABLE FOR USE N 1. SEE AD-TD-0001 FOR ADDMC NAL REQUIREMENTS. ALL 010 ZONES AND N BOTH EXPOSURE 'C' AND EXPOSURE V. HOWIEYER, BY INSTALIAIG THE MARE RE -DOWN STRAPS AT THE 'OUTBOARD! 1-BEAN THE MAX 2. SEE OTHER DETAILS FOR BLOCIONG (PIER) QUANTITY AND OTHER REOUIREMENTS. HEIGHT OFF THE GROUND IS GREATLY REDUCE°. SEE OTHER DETAILS FOR THE 3. FOR FIGURE 6.0 SEE OFFSET UNIT TIE -DOWN SPACING TABLES (AD-TD-0020). RECOMMENDED MEINOOS FOR INSTALLING FRAME TIE -DOWNS. 4. FOR FIGURE 6.1 SEE NORMAL TIE -DOWN SPACING TABLES (AD-TD-0010). ENGINEER I/, OAPIA APPROVAL: 5. ZONE 2/EXPOSURE ALSO SEE AD-M-oV. 02 32µDLIKWUU HEIGHT .�`````�� • C �'DO��'''''-i ZONE 2/EXPOS1RE '0% 24- MAXIMUM HIOCHT PPROVED BY .� Q �,�S7ER ••.F - ZONE 3/EXPOSURE 'C': 24- MAXIMUM HEIGHT 0. ZONE 3/EXPOSURE '0. 28- MAXIMUM HEIGHT z E870 .11�1 i 5 t�96 -• INC NTP y vCWrnTr+04a JACOBSEN HOMES Dim S1E�TM � MA►= I+ � `"+ C.Q.Y. DATE- 5-30-95 �" `�"�` 11111111+ ORIGINAL. PROPRIETAR1; ANO IAN UAIML DRAWING TITLE: P.O. Box 368 „ MATERIALS OF JACOBSTH MANAPACTUiX GIG. 6.0 qX, MASS ARE PRON�D TO DIE �.) N,G SAFETY HARBOR. FLORIDA 34695 . KOPEK FOR 91CM PIAP(is<S NO MAT E DRAWING NUMBR PHONE (813) 726-1138 IIPT COMOER& AND SECRET IRGII onm AO-TD-0033 45' ADDENDUM �Ug� _ T ALTERNATETIE DOWN ' SPACING TABLES �( D ZONE II & III/EXP. C & LONGITUDINAL TIE -DOWN SPACING TABLE F+1 MIN. W,ND ZONE II WIND ZONE III UK on. ANCHOR uw oTr. ANCHOR V FLOOR EA. END Of ANGLE EA. END OF ANGLE WIDTH EA sEcnaH MIN. a EA SECTION MILL e 12'-0' 2 43' 2 55, 13'-4' 2 50 2 68' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE WN. MAX, HIND ZONE II WIND ZONE III SPACING I �� ANCHOR ANGLE SPACING LOAD DEL. HEAD AN ANGLE FLOOR OVERHANG EAVE 12'-0" 6' 4'-0' 37501 20' 4'-0' 3900j 22' IS-4' 6' 54 3850 j 25' 5'-4' 3960# 30' THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS LONGITUDINAL TIE -DOWN SPACING TABLE i' (� MIN. WIND ZONE II WIND ZONE III IN. oTr. EA. END OF A1mEDR ANGLE ulx. OTT. EA. DID OF u+a+oR ANGLE v FLOOR S� \v\ p WIDTH EA SECTS UK 0 Ell SECTION UK 9 V 12'-0' 2 64' 3 47* 12'-0* 3 37' 4 33' �O I. 13'-4' 3 42' 3 55' 13'-4' 4 30' 4 38' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING�- HEAD ANCHOR ANGLE SPACING DB OAADDAD ANCHOR ANGLE FLOOR EAVE WIDTH OVERHANG LOAD 12'-0" 6' 4'-0' I3950# 25' 2'-8- 3930@ 20' 13'-4' 6' 4'-0" 39601 25' 2'-8' 4000# 30' THIS ALTERNATE APPLICATION REQUIRES, 4,,000 POUND ANCHORS NOTES ENCittE(a FR�L. O� 4i OAPIA APPROVAL 1. SEE AD-TD-000T FOR ADDITIONAL REOUMENTS .�'��O? 'c,�STER • FZ �� �; N0. lc0 APPROVED BY 2. SEE AD-TD-0036 FOR MAXIMUM PIER HEIGHTS REOWIZED FOR THE LOADS TABULATED ABOVE. Qk, = ' ENES703571 _ _7N] [f I 5 3. MAX EAVE OVERHANG REFERS TO OVERHANG AT SIDEWALL NOT FRONT�OR REAR. I C 4. ABOVE TABLES APPLY TO 160• FLOOR OR 144' FLOOR WIDTHS WH 95 1/2' �•� ` ���•'•. / 6 q` •����� �� • No `-. •,(�� rtntwK roves t V 41 taawCtA1os�HTriLrp�Ip I -BEAM SPAC1% 96' MAXIMUM SIDEWALL HEIGHT AND 6' MA7W(UM SID E•,� • ��• ����i S'S/� • OVERHANG (6. OVERHANG MAX EACH SIDE OF UNIT) t..... E` ����` JACOBSEN HOMES NOTICE • f 4/+M THESE ��TIMS AND ORAKM ARE WONAL, PROPRIETARY, AND CI7181DE11TIAL C.L.Y. DALE 5=30-95 REV. LETTER A DRAWING TITLE TABLES MATMALS OF JACOM UP UFACTMNO ALT. SPACING P.O. BOX 368 SAFETY HARBOR, RCIRIDA 34695 PHONE (813) 726-1138 N- Wm YATEiMU ARE PROM W TO THE RECMT rat 9ECric PLL61= APO M57 BE IIEPTIi)DItF1DD TK APO 100 FROM O1N'n DRAWING NUMBER AD-TD-0040 46 ovo's �poo� R,%p ADDENDUM ALTERNATE. TIE —DOWN SYSTEM TYPICAL CROSS SECTION SHOWING TIEDOWNS ANU MOLE FIGURE 7.0 SEE FIGURE L3 FOR RECIMIDED TIE -DOWN METHOD IMPORTANT NOTICE: SEE NOTE 4 FOR WAN HEIGHT THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS M USING THIS TIE-DOW CONFIGURATION A STYIB CREST PRODUCTS YODEL 573H (TYPE 21 AUGER ANCHOR TO A DESIGN LOAD (WOWIG IDAD) RATING OF 4,000 POUNDS AND AN ULTIMATE LOAD RATDX OF 8,OW POUNDS MUST BE USED. AN EQLDYD,ATR ANCHOR IdLW THE ABOVE SPECIT mNS WE BY ANOTHER MANUFACTURER MAY BE USED IN LZU OF THE STYLE CREST PRODUCTS ANCHOR. NOTES; 1. SEE AD-M-OODI FOR ADDITIONAL REQUIREMENTS 2. SEE OTHER DETAILS FOR BLOCIONG (PIER) QUANIITY AND OTHER REOUIREIOTS. 3. FOR FIGURE 7.0 SEE ALTERNATE TIE -DOWN SPACING TABLES (AD-TO-0035). 4. ZONE 2/EXPOSURE 'C': 38' MAMUM HEIGHT ZONE 2/EXPOSURE '0': 28' MAXWUY HEIGHT ZONE 3/EXPOSURE 'C': 28' MA)3WUM HEIGHT ZONE 3/EXPOSURE 'D': 28' MAIOMUM HEIGHT 5. SEE AD-TD-OD35 FOR ADDITIONAL NOTES THE ALTERNATE TIE -DOWN METHODS SHOWN ABOVE ARE ACCEPTABLE FOR USE IN ALL WIND ZONES AND IN BOIN EXPOSURE 'C' AND EXPOSURE V, HDWEVER. BY INSTALLING THE FRAME TIE -DOWN STRAPS AT THE 'OUTBOARD' F-BEAM THE YAX HEIGHT OFF THE GROUND S GREATLY REDUCED. SEE OTHER DETAILS FOR THE RECOMMENDED METHODS FOR INSTALLING FRAME TIE -DOWNS. . O?'•�G�STFA Q No. ,FNEa7Q24*� IN A APPROVED BY oLN`6 G con3—io.4w wcn SiMOMOD JACOBSEN HOMES 1" P.O. BOX 368 NM#m �'�<ls TIiSE SPEH7FiCAT10115 AND DRAIWG$ AaAE aEaMAI, PROPIaTN1Y, AIN CCIfFDDITIK YATFRIALS OF JACOBSEII YA:ACT A rK SUCH MAMUS Ara PRAM TO 7NE ���CPI�°°''. C.L.Y. °A�` 5-30-95 �1 DRAWING 7ITLE FIG. 7.0 SAFETY HARBOR, FLORIDA 34695 AEC w FOR sm pifto NO YIAT i DRAWING NUMBER: PHONE (B13) 726-1138 IDPT CWWTIN. AND SEaET FROM ortm AD-TD-0041 47 ADDENDUM SC. TIE -DOWN PROTECTION OF STRAP IS PROVIDED AT UPPER CORNERS BY FIRST WRAP OF STRAP. SEE DETAIL B ( I \ FRAMCOMEEOFF HE 'TOP'ROF THE AP AI -BEAM SEE DETAIL 'C' DETAIL 'A' IUCKLE WIT} 31501 Y MINIMUM (DESIGN LOAD) DETAIL `B' NOTES: 1. SHOWN ABOVE IS ONLY ONE METHOD OF STRAPI ATTACHMENT AT BEAM -OTHER METHODS THAT ARE CERTIFIE TO MEET THE REQUIRED DESIGN LOAD OF 3150# MAY BE USED. 2. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CUP). PULL DOWN TIGHT TO GROUND ANCHOR INSTALL RADIUS CLIP (SEE AD-TO-0200) OR C SIMILAR DEVICE TO PROTECT STRAP .AT ALL SHARP CORNERS. DETAIL `C' THIS TYPE OF PROTECTION MAY BE USED FOR ,;q,3jQH,,AT LONGITUDINAL TIE CONNECTIONS ALSO. �.. srit�y%,,, O.Tmuu cwncyvTo: � nF •. • %. Q No. o 910334 STATE OF.: IA siri AND J AC O B S E N HOMES T sE SPE.FICAnQTs`ACWo oRAnlNo ARE DRONAL. PRa'KTAR' AND Ca1FDDT1IAL DRAWING P.O. BOX 358 UATMALS OF JACOBSEN YANUFA SUS NG INC SU01 YATMALS ARE PROMM TO TT£ SAFETY HARBOR, FLORIDA 34695 RECMI FOR SPEWC P1IRP0SE5 µD MT BE ORAVANC PHONE (813) 726-1138 KEPT COtiMTIAL AND SEMI TRW OTTERS DAPIA APPROVAL. - APPROVED eY 000or ON 11 FMFRAL MMUFACMED HOME H S NOV 2 4 1998 M.T. DATE: 11-18-98 REV. LETTER: MISC. TIE -DOWN B AD-TD-0050 48 ADDENDUM NORMAL TIE -DOWN SPACING TABLES ZONE II & III/EXP. C & D 1� LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III `1 FLOOR ft CITY. AK43R UK OTY. ANCHOR EA. END OF LE EA. SEOF ANGLE O WIDTH EA. SECTION UK RL B [A. SECTION 1AN. e 3 40 3 25 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III FLOOR EAVE DSL ► EAD DeL WA WIDTH OVERHANG SPACING LOAD LOAD aNCK1R ANGE SPACING ANCHOR ANGLE 30'-8' 6' 6'-9' 31501 41-46 5'-5- 31501 44-49 LONGITUDINAL TIE -DOWN SPACING TABLE t� MIN. VAND ZONE II WIND ZONE III �U FLOOR UK OTT. ANCHOR UK Olti ANCHOR VADTH EA. END OF IN. SEC EA. Of K �.J ESL SECTION MIN. a EA. sEctIDN uua. e 9-87 4 42 4 25 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE Q WIND ZONE 10 FLOOR EAVE SPACING DBIL R'`AD ANCHOR ANGLE SPACING Del. HEAD ANCHOR ANGLE WIDTH OVERHANG LOAD LOAD 30'-8' 6' 4'-6' 31501 46-50 4'—p' 31501 1 49-52 NOTES: I. SEE FULL ADDENDUM FOR ADDITIONAL REWIREWNTS. 2. SEE AD—TD-0071 FOR MAXIMUM PIER HEIGHTS REQUIRED FOR THE LOADS TABULATED ABOVE c 4/4 - 974.G1- 11111111u,.. nt �� (y:.�G�STER� .• � �.� Q No. o'• 910334 STATE OF'-'� c JACOBSEN HOMES 4 THESE SPEpF1G11XIN5 A11D auaracs ARE CRONAL• PROPRIETARY, AN0 OOP UNTIAL P.O. BOX 368 MATERIALS OF JAC089A 1IUWACIMiNe SAFETY HARBOR, FLORIDA 34695 01C 9 N NAIDSALS ARE PROYM 10 0[ RECRENT FOR SKCS PUt M AM VM gE PHONE (727) 726-1138 KFI WOODMAL #4 SECRET mow ono¢ 11ANDZONE III (110 MPH) 20 PSF ROOF 10 PSF D.L. DAPK APPROVA p 0 S In APPROVED BY IN14 "CEIuawrArAnaleowAE INC. man�clauwsArErrstANsuos iq"� DATE M.T. 2-8-99 NORM. SPACING TABLES It AD—TO-0070 "C° . 49 ADDENDUM 11 TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS MAX PER 0-TD-0010 TABLE PER AD-TD-0010 TYPICAL CROSS SECTION SHOWING TIEDOWNS SET MCHOR LEAD OF (TYP1 SEE TIP. FLOOR -DOWN SYSTEM PER AD-TO-0010 TARE PER AD -ID -WO TABLE ' PER AO-ID-0010 TABLE MAX FIGURE 10.0 20 FOR ALTERMAN M-DOIN KETHOD TYR 005-ML]ffRR —01AS9S / ANCHOR ANGLE FIGURE 10.1 SEE FIGURE 50 FOR ACIERIM =-DOWEL METHOD ITff. CALCS. 3 SEE NOTE 5 FOR 4 MAXOIW HEIN N C `"4- 11, e*— 9/. WINEIZONE III (110 MPH) 20 PSF ROOF 10 PSF D.L. NOTES: EN W, 091 E.! DAPIA APPROVAL•. 1. SEE AD-TD-0070 FOR SPACNG TABLES. ' ?� No. APPROVED BY 2 SEE AD-ID-OO70 FOR QUALITY OF LONG11WAL 11E-OONN STRA �S REOURED. z 910334 3. SEE OTHER DETAILS FOR BLOOM (PER) QUANIITY AND OTHER REOUIRE MENTS. r 4. SEE FULL ADDENDUM FOR ADDITIONAL REOURBOTS. ;.-o ; STATE %A ;•W 5.. ZONE 2/EXP0SITRE V. 56' MAXIMUM HEIGHT INC. ZONE 2/E�OSURE V- 40' MAXIMUM HEIGHT �ii� !fir,... ,� FE�MMW�p� ZONE 3/EPOSURE V: 56' MAXIMUM HEIGHT ��i ��" �TMOO Mos�rrsarOM ZONE 3/EX POSURE V.- 40' MAXIMUM HEIGHT s,. ........ . .. JAC 0 BS EN HOMES N0T1 DRA DATE REV. LETTER: TIfSE sPEa1cATlaHs AM 10 oRA NGS ARE M.T. 3-1-99 draOM PROPREURY. AND Car immim DRAWING TITLE: ffHmM,F P.O. BOX 368 MA11_ IEAIALS Of UCOBSEN UQAFAC FLM FIGURES 10.0 AND 10.1 alai MATMALS ARE PWVM TO THE SAFETY HARBOR, FLORIDA 34695 REOW FOR 9E1 M ROM AND WST BE DRAWUIC NUMBER: AD— TD=0071 PHONE (727) 726-1138 WT C%fVU ML AND sEM FROM OWrE ADDENDUM. gas NORMAL TIE -DOWN SPACING TABLES ZONE II & III/EXP. C & D 1 / LONGITUDINAL TIE -DOWN SPACING TABLE v ^ O Y MIN. FLOOR WIDTH WIND ZONE d WIND ZONE 11 YIN. OTY. EA. END OF EA. SECTION ANCHOR ANGLE UK a YOL Olt EA DO Or Ell SECTION ANCHOR A NGLE YW O 15'-4' 3 45 3 35 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX WIND ZONE II WIND ZONE III FLOOR WIDTH EAVE OVERHANG SPACING DL LOAD ANCHOR ANGLE SPACING ° LOAD ARGICt ANGLE 154 6' EACH SIDE C-10' 31501 40-46 5'-6' 31501 42-47 LONGITUDINAL TIE -DOWN SPACING TABLE (� O MIN. FLOOR WIDTH WIND ZONE II WIND ZONE nl OTQTY.ANGLER EA. Jl E END OF EA. SECTION ANGLE YOL 9 ID . . DID OF EA EA SECTION ANGLER ANGLE Y9L 8 15-4' 3 30 4 35 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX WIND ZONE II WIND ZONE III FLOOR WIDTH SAVE OVERHANG SPACING DBI. run LOAD ANCHOR ANGLE SPACING O LOAD ANCm AMU 15-4' 6' EACH SIDE 4'-6' 3150142-50 4'-0' 31501 44-50 VANDZONE IN (110 MPH) 20 PSF ROOF 10 PSF D.L REF. CALCS. c w 4 — j /2. (/I — -72 , l6 TTTrrLrrrt NOTES: I. SEE FULL ADDENDUM FOR ADDIDONAL REOLI MENIS. 2. SEE AD-TD-0073 FOR MkVL4JM PIER HEIGHTS REWIRED FOR THE LOADS TABULATED ABOVE 3.. MAX SAVE OVERHANG REFERS TO OVERHANG AT SIDEWALL NOT FRONT OR REAR.IN / 4. ABOVE TABLES APPLY TO 184' FLOOR VADTHS WITH 95 1 2• I -BEAN SPAGNG, 46' MA)OMUM SIOEWALL HEIGHT AND 6r YA70YUM SIDE OVERHANG.(6- OVERHANG MAX EACH SIDE OF UNIT). ENO``L R OVAS .Tj � `��� co \STEq�.�! •� Q� No. O 910334 �,• STATE OF :��,` . , p P,•� : '� �' \ ��""'��° �' S '' , DAM APPROVAL•MW gPPROVED BY INC. wltsn�cTawor+vrTrtwaRRr JACOBSEN HOMES ® P.O. BOX 368 „ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 Nor, AILr TxESE sPEanwTloxs AND IIRAWNC$ ARE ORCHAL PROMETARY, AND CoftiLNIIAL MATERIALS OF KCOOSEm MMOSACTURING W_ SUdI YATEMALS ARC PROVIDED TO THE RCtma fart SPEarc PIR m$ kc UZI K ►YPT Winxxlm AND SECRET rROV cuts Le BY: M.T. DAIS 2-8-99 REV. LETTER DRAWING TITLE: NORM. SPACING TABLES DRAWING NUMBER: AD-TD-0072 SZ4 ADDENDUM TIE -DOWN SYSTEM — ,.r-1 -. 1 .. rm n,-lu-wil. MAL nx w-lu-wiz 1pm nx w-111-wiz mu PER *_m_ D12 TARE Ila FIGURE 10.2 SEE FIGURE 20 FOR ALTERNATE TIE-DOVN YEI'FWD TYPICAL CROSS SECTION SHOWING JIEDOWNS M. FLOOR SISIEM 11 SEE NOTE 5 FOR YA=IW HEXHT N ANM ANGLEANGLE ANC}IOR OF NX ) � FIGURE 10. 3 ( SEE FIGURE 7.0 FOR ALTERNATE IIE-DOWN i IIOD NOTES: I. SEE AD-7D-0072 FOR SPACING TABLES AND NOTES. 2 SEE AD-TD-0072 FOR OUANITY OF LONGITUDIAL TIE -DOWN STRAPS REQUIRED. 3. SEE OTHER DETAILS FOR BLOCKING (PIER) OUANTITY AND OTHER REOLIWO TENTS 4. SEE FULL ADOETD N FOR ADDITIONAL REQUIREMENTS 5. ZONE 2/1E)POSIM 'C: 56' MAXIMUM HEIGHT ZONE 2/0POSLIRE V. 56' MAXIMUM HEIGHT ZONE 3/EPOSURE V. 56' MAXIMUM HEIGHT ZONE 3/0POS11RE V. 56' MAXIMUM HEIGHT REF. GLa. C q2. ..Nluullu,.._ .G%ST E,q '•��! � No. Fo 910334 -Q STATE CF JAC O BS EN HOMES THESE SPEQFlOA�IMS � oR,+►,(cs ARE ORCINAL. PROPRIETARY, AND omnDEENTIAL „ BOX 368 MATEAULS Of .MOOS), „ANUFACRMING P.O. SAFETY HARBOR , FLORIDA 34695 D_ 9xH MATEM+ua ARE FTtMM TO THE AND um PE PHONE (727) 726-1138 APT CONNRI)OM& WD gUM FILCH UMM WINDZONE III (110 MPH) 20 PSF ROOF 10 PSF D.L D" APIMK APPROVED BY 0 oor N A RLOHYa,iWf�CR/I®NO,E INC. oasTraa,Awwertwalol M.T. I DATE. 3_1-99 REV. LETTER. FlGURES 10.2 AND 10.3 AD-TD-0073 52 ADDENDUM �S Slit1� OFFSET UNIT TIE —DOWN SPACING TABLES 1 ZONE II & III/EXP. C & D LONGITUDINAL TIE —DOWN SPACING TABLE MIN, HAND ZONE II WIND ZONE M Wt Im ANCION NI11 on AWN FLOOR MOTH END OF ANGIf F OF A END A O EA SOON U 1IT1L a FA SEr1;1a1 K � e 12'-0' 3 47' 3 61' v� 2 54' 3 41' 15-4' 2 54' 3 41' VERTICAL TIE —DOWN / FRAME TEE —DOWN SPACING TABLE MIN. MAX. WIND ZONE I WIND ZONE 0 SPAMLOAD ANCHOR ME SPACIIG MIL HEAD MGM ANGLEMOTH FLOMOTTHH OVERHANG EAVE 12'-0' '12' 5-0' 31501 40' 4'-0' 3150# 39, 12' 5-0' 31501 41' 4'-0' 3000 j a 15'-4' 12' S'-0' 31501 43' 4'-0' 30001 4T LONGITUDINAL TIE —DOWN SPACING TABLE MIN. WIND ZONE I WIND ZONE NI A. EA ENDD OF A1aroR AN" WE QTY.N+ai EA END OF OR MILE 1J FLOOR �� O WIDTH FA SEC11011 L!l e FA sEceD11 rL e 12'-0' 4 45' 4 60' 3 45' 3 60' 3 45' 3 60' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE FAIN. MAX. WND ZONE I WIND Zm 8 SPAM Lw ANCHOR AM SPAM DIL WA In ANCHOR ANRE FLOOR WOlH OVERHANG 12' 4'-0' 31501 40' S-0' 30001 39' 12' 4'-0' 30650 41' 3'-0' 30001 3' 15-4' 1Y 4'-0' 3M 43' 3'-0' 30001 41' MOTES: f-6, 05 _ C4 L4.5, c- sL - 1.6 12- ENGINEER A +PjipYAE^ 4 4111 e f ff. CALCs C — U - 17c - p •, 17 , O 1. OFFSET SECTION WIN THE MARRIAGE LIE WAIL EXTENDING BEYOND THE ENDWML OF BE TIED Dorw AT THE MARRIAGE LINE N.AHxIDRDANCE .•i✓�......... �O �� ••� q�:•., y D BY THE ADJACENT SECTION Must •. G WITH THE TABLES ABM THE SIDEWIAIL SIDE AND THE ADJACENT SECTIONS) ARE TO • BE TED DOWN N ACCORDANCE NIH'THE NORMAL SPACING TABLES (SEE AD-TD-0010 • JUN FOR 12'-T & 13'-4' VMDES, AND AD-1D-0070 FOR 15-4' NIBS * ' 2 SEE AD-TD-0001 FOR ADDITION& REWIfEIENTS. STA ; INC. 3. SEE AD-TD-0081 FOR "* M PIER HEIGHT REWIRED FOR THE LOADS TABLILAI D �yE s •. c� J' Q • •:,� O R19p:•• ��+ •: L MANI1fxCTUiI� ItOATE • gums JACOBSEN HOMES N r� >fmsA���► '��•T• DATE- 6-8-04 Kv. tEr� DRAWN 111M OFFSET SPAUNG TABLES P.O. Box 3sa . GIN KY, MV. i 17Q IALS °F A erg" M""UF to A SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 W. sllal MAXIM ARE KOW FCR 9Eli1C I+IhP M Or oOIFIDO & NO I DRAIYNG KNEIEtt AD—TD-0080 ,553 15F ADDENDUM OFFSET UNIT TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) ninwun rr nnuM menu^. TIE -DOWN SYSTEM FIGURE 11.0 Sm Pim 4.0 RR 911=2 72-DOVN 1D WD [TALES ON AD-1D-M DUE AIRY 10 30E SFANAAM iK -ICE SECDdIS OF TIE UNIT -SEE NOTE I, WM-M] TV. CROSS SECTION($) TYP. Rm sTsEm SHOWING TIEDOWNS TDP. FLOW SYSIDI--7 SEE NOTE 5 FOR 71 1 L III MADMI IEIIiIT A AND'IL� � � Algiat ANGLE_ ANGLE . ANGLE FIGURE 11.1 SRI n= EE FOR AM= 19401IN STD TIP. Man ANGLE—I'R � svice i�.oJ' FIGURE 11.2 (r 7.08 04 IN u1mm W-DODN 103180D NOTFS•un+*�yc,YrO� e. DAE'IA APPROVAL I. SEE AD-TD-0080 FOR SPACING tAe1Es (ofFSET sEc110N oNLDO PPROVED BY 2 SEE AD-M-M FOR 0UAN1Y OF LCNfiAM TE-DONM STRAPS REMM. '� ,•' G' F ✓ (OFFSET SECTION ONLY) 0. (?(j4 � e a SEE OTHER DECALS M BLOCKNiG (PIER) QUANTITY AND OTHER REQIARE)1ENTS. ', JUN 11 20 4. SEE AD-TD-0001 FOR AODRIO K REQUIREMENTS. OG�• » S. ZONE' 2/EltP06URE 'C: 48' AIA)0Z11Y HEIGHT � • INC. ZONE 2/E)Q+061IRE V: 40' MA)OMUM HFJCEIT-36' FOR 12'-0' WADE UNITS '�9�. '••• � OP. ��qFE IERAL NUFACTURED HOME ZONE 3/E)O'OSIIRE V. IT!' MAX4IUY FEICHT • �' � �� TRUCNDN AND SAFETY STANDARDS ZONE V: V: 40' MASIN FEItEiT JACOBSEN HOMES 11 mncm r`''" „M VEaFlMMS AID MAWM ARE � M.T. DATE 6-8-04 REV. LETTER BOX • PWNTE Y. AM CONFMM M"10M OFJACOBSEI) MWACRAR�N' OR/1WWG 111 L. FIG. 11.0, 11.1 & 11.2 P.O. 366 SAFETY HARBOR, FLORIDA 34695 mT Fq SA)p MIST If DRAYS O' PHONE (727) 726-1138 WT OWW'DAL AND SIXRET FROM OIDERS AT)-TD-0081 54 ADDENDUM ALTERNATE OFFSET UNIT TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SHOWING TIE -DOWN SPACINGS FIGURE 12.0 SEE FIGURES 11.1 AND 11.2 FOR NOTES: 1. SEE AD-TD—MM FOR SPAONC TABLES (OFFSET SECTION ONLY 2. SEE AD-70-008D FOR OUANITY OF LON07UDIAL BE —DON STRAPS REWIRED. (OFFSET SECTION ONLY) I SEE OTHER DETAILS FOR BLOCKING (PIER) QUANTITY AND OTNER REOUIMMENTS. 4. SEE AD—TD-0001 FOR ADDITIONAL REOUIRENENTS. SEE C41 , P6, (-sd- Ifs•o- /6.m SECTION 910334 00, STATE Of : �w DAPIA APPROVAL Rk. MAN":FACTiIRE0 F .M. STRUCT.IONA1, SAFElYSTA,.0ARJS JACOBSEN HOMES NOTICE — DRAW Or R.R. DATE s-9-ol" LETTER: TIESE sPEaTICAnoRs AND piA1tINCS ARE COCWAL PROPRIETARY. AND OQ WIIAL DRAWING TITLE: FIG.' 12.0 P.O. BOX 368 MATERIALS OF AC0901 YANUFACnIRWG 34695 W' sm MAIMS ARE PRONIKO TO THE SAFETY HARBOR, FLORIDA AECAPIT FOR SKCRC FLNPOKS AND MUST K DRAWING NUMBER: PHONE (727) 726-1138 arT cQY mun AID SECUI RROU DOM AD—TT)-0082 i ADDENDUM 108" HIGH SMEWALL TIE —DOWN SPA ING TABLES 1� 0 ZONEII & III/EXP. C & LONGIT im TIE —DOWN SPACING TABLE r' NI. IMND ZONE N WND ZONE N FLOOR OTY. Mon MIL OTY. AM= lfi EN OF AIMiE Ell E10 ff ANOi O 26'-e grz i 3 WL 9 42' EA SECU 3 WL 9 53' '- 30 8' 3 52' 4 45 VERTICAL TIE —DOWN % FRAME TIE —DOWN. SPACING TABLE UK MAX. WIND (ZONE A WIND ZONE I LA OBiA WIDTTH OVERHANG SPA= MNOIOR AWE SPA= MiM MIf1E 26'-8' 6° 6'-8' 31501 4(r 5(r 1 5'-4' 31501. 40' 50' 6' 6'-8' 31501 40 -W 5'-4' 3154 40'-50' LONGITUbINAL TIE —DOWN SPACING TABLE MIN. j WW ZONE N WIND ZONE 10 FLOOR aman Iff rSECITY MMiE WL OTY. FA END ff AtIm ANCIE WOTH 1101 O 26'-Ir 4 MIL 9 41' EA. SEC110It 4 MIL 9 T 36-89 4 1 51' 4 70' VERTICAL TIE —DOWN a FRAME TIE —DOWN SPACING TABLE �IUL MA% WIND ZONE A WIND ZONE 0 FLOOR W EAVE OVERHANG SPAOI% I Mlaron AMaE SPAONG BEL WA MlUR Al#aE Lm LOW 26'-8" 6' 5'-4' 31501 4O'-5(r 4'-0' 3150# � 45• 30'-8' 6' 5'-4' 31501 4O•-50' 4'-Cr 31501 40 -45' 1NNDZIONE M (110 MPH) ZO PSF ROOF 10 PSF D.L PER CALM c5-41•- I fat — for 21.3 NOTES: ENIL•.:. .... •�,j►Fi� ��' �, �� DAPIA APPROVAL • t. SEE PAL AODE111riM FOR ADDI11Ut1Al REaUIREl1EN1S �� = O� y �;; APPROVED BY r Na 0045484 0- 'Oro 2 SEE AD1D-M FOR MA)Q M PIER HMIS REQUIRED FOR 7W LOADS TART AM AtIObE a NC. FEDERAL MANUFACTURED HOME r��1 rrF�ED E�G� �: CGNSTRUCHONAND SAFEP( STA?10ARUS JACOBSEN HOMES NM �G� � �� � �"� OrM•T• D"'� 07-20-04 REV.L� P.O. BOX 369 QVQ+AL PMPFIEWT. AND *+L DRANNG W ERAS OF MOM UWAC1URNO RUE- 108• HIGH SIDEwAII SPAaNG TABLES SAFETY HARBOR. FLORIDA 34695 PHONE (727) 726-1136 me SM MAMIMS ME PR01oED A 1E Rt MN RN SFBi1C P1N'OSES NO Hest E DRAMNG part COimna wo mu mm olm NUM3M AD-TD-0083 i TYPICAL SIDE ELEMAWN SHOWING TIE -DOWN SPACINGS ADDENDUM TIE -DOWN SYSTEM FIGURE 10.0 TYPrzoss sEcnaN I I III SHOWICALWcG 11EUOWNS TV- am ST510H7 TV. man M E SET mom HEIR FIGURE 10.1 sm Now 6 fm ,� riAIH1IIH HIBOIT 1 r 3 1MIOZONE ■ (110 IIPH) 20 PSF ROOF 10 PSF D.L bid-. DAPIA APPROVAL NOS ;��o:'�►�'F ' • 1. SEE AD-ID-M FOR SPACING TAKES APPROVED -BY : �, • 2 SEE AD-ID-OOR.7 fit QUANITY OF LONGIMAI. TIE-OOW sTRAPS REOUTAED. 3. SEE OTHER DETAINS FOR mLwaNG (PER) OUANnTY NO OM REOUiHE)"'IS d ! 4. SEE FULL AODEIDUM FOR ADDHTH)NAL REOURE11 M ; � S ZONE 2/E3P091RE V. 36' YNI1M1 Hf1CFIT INC ZONE 2/DPOsK V: 2r NAMN HEIGHT �•.•. (4 ��►! INF[l ZONE 3/E7�09NHE V. W YA)URN HEIGHT � .ORIa�. ' o � C/ ;... � ♦ fEDERA!_MANUfACTUf1E0 HOME ZONE 3/E�OSURE V- 3Y YAWN HEIGHT N �• % cONSTRHICTIONANOSAFEiYSIAV)AHUS 8. ALL SPECIf1 ims ARE BASED ON 20 RODE mu mAx- �•,I. � � 1,�,� t 7 20 NOTIM: ''= M.T. oAn: 07-20-04 REV.u:TTE� JACOBSEN HOMES 1H� �Tm APO �� ARC QMAL. q°WWMY. AND CWWB lK DRA" nn''` YATMS CF YANWACUIC 'FIGURES 10.0 MD 10.1 P.O. BOX 368 NG 2 01 MAXIMS ME F�Ii AM 10 WE SAFETY HARBOR. FLORIDA 34693 mww fm swc pIFm AO MW E DRAVK PHONE (727) 726-1133 ITT mimtlm no leM FM am AD-1D-0084 97 ADDENDUM . lOB" HIGH SIDEWALL TIE —DOWN SPACING TABLES ZONE ll & III/EXP.. C do D LONGITUDINAL TIE —DOWN' SPACING TABLE WIND ZONE 1 WIND ZONE 19 V F1oDR • Ya. an mm Yap on nH n ADDENDUM TIE -DOWN SYSTEM i1fPiCAI SIDE DIVAIM . SHOWING ilE--0OWl1 SPAQ0. FIGURE 10.0* �i ■ __ BIT` �f ANoIaR A11LlE oa AFFR04FD STABI@1 TMST m MIN Al m 9UFT 1ETI x I � FIGURE 10.1 . 'sssNS 31 sIs 1, AO-10-M TABI 7% • `F,•�0 SM FOR M'AMIG 2 SEE AD-iD-GOBS FOR aAMTY OF LCNfiNOAL K-DOMN STRAPS REOUAED. �o . C� 3. SEE 010 OETARS FOR K000 6 (PEA) QUANTITY AND OM REOUREYElM 4. SEE ALL AODENOUM FDN ADOOIONAL REDIARDENM i t a.! a Z01K 2jDP0AAE'C: 44• 11A0 N Foam ZDlE �/EIIPOSINE T-. 2r MA)UN 1E W 1 ZdJE 3/E�05URE 'C': 4,C -MAMN i WIT bt W MA W HDPff :•. F� �. ,� + l� ZONE J/E7<►OStIRE 5. ALL MUT06 ARE BASED ON 217 ROOF ANOIE MAX AND Ne MAX L�pi;1 ,.• ++I cj • ... •• SIOEWALL HEP L NcImr, pals 1"RUt JACOBSEN HOMES l"" AK O OUL rROrillu . A14 Ovs1DEJ11Ml UTAIRIB llTl tuwms cr xamm mwF AesA�11e P.C.tloz J6B „ SAFETY HAREM, FLORIDA 31695 w_ &a MllUUIS AK H1w M 10 K MW K DRAWN NU PHONE (727) 726-1135 ivr wnaput �4 �[0[1 nor WMZGK 1/0 (110 mm) - 20 P7 ROOF 10 P5F D.L DAM NgWAU APPROVED BY .: Dec 13,2006 N. INC. r � FEDEA'Al wN11iAC11:�lD HOME 'w ONSnWCnON AND SAFER' STAMMIMS R.R. DAL 11-28-06 rEx FIGURES 10.0 AND 10.1 AD—M-0086 ADDENDUM Ala (1oa �IDEWALIP} NORMAL!, TIE -DOWN SPAdINC -TABLE$ ZONi E 11 & III/EXP. d & D LONGFrUDINAL TIE -DOWN SPACING TABLE (� SIN • I�ND ZOlf u ow IOl ta FLOOR q Ott OTT. ij O� 1P„ 12`-00 tp E►q ar EA SEC1101( 2 s wi a 53' Eel dp OF EA SEC110N 3 >t l g 40' 13 -4` 3 37' 3 46' 15-4` 3 1 45' 4 40' VERTICAL TIE -DOWN FRAME TIE -DOWN RACING TABLE �11N. VAX. JAD ZONE a ZONE 11 $DTTHH OVERHANG I T kip" #of• SPA* mm � A10M AOr* 12'-0' 6f EACH SIDE 5'-4' 72" 35' TO MY 5-4' 3r 45' 13'-4' V EACH SCE 5'-4' p Be 35' TO 40, 54 42` 45 154 a EACH SIDE T-4' 80` 40' 54 of 45 LONdITUDINAL TIE -DOWN 9PAGING TABLE � I 1r�N. ZONE N ZONE tl FLOOR E1 v , EA ft ff + � 12'-0' EA SECT1011 3 1r11(. a 44' EA. SECAON 4 g 40' v 13'-4" 4 45' 15'-4` f::±4 44•1 4 56. VERTICAL TID- DOWN �i/ FRAME TIE- DOWN ¢PACINU TABLE V VAX im ZONE 1 0 ZONE 11 FLOOR MOTH EAVE OVERHANG SPA* VAX PIER �T A►IOIOR At(pE• sPAoNc ��� , �+ 12.-0 6 EACH SUE 4'-0' 7t 1 37' 4'-0' 34" 40' TO 45' 13'-4' 6 EACH SIDE 4'-0' "72" 40, 4'-0' 3r 40' TO 45' 15-4" 1 a EACH SUE i 4'-0" w 40' 4'-0' 42' 49 TO 45' • NOTE: WHEN ANCHOR ANGLE FROW VERTICAL CANNOT 9E ACHIEVED. ADD APPROVED STABILIZER PLATE. � �� (SEE NOTE #5 FOR ROVES SET IN FLORIDA)`��j' '••s, NOT . 1. SEE FM AODftW FOR AD�nONAL REOIARi�iENTS EN • A ,, `6 r� *'?�' �L' ;'-� : `�:.� `f �� 13•..,i DAM APMvA APPROVED BY 2 TAKE BASE° ON ANCHOR *DRIONG LOAD OF .11501 AND Dul!)ONAL nE To D3POSTEBEAf;L ' 1„• r c: •• ii:.v, .:e-t'* 25,2008 N AINC. 3 VAX SAVE a"ANC REFERS TO OVERHANG AT SDE*ALL NOT FRONT OR' NEAR �" :1Z rr FEDENfLL rAMuvAcruDNon 4, TAB1E5 APPLY i0 144" 16O', AND 184' FLOOR fjQ1N5 iH 95 1%1' I SPACK lDe F,iAmU SOC�'Aa HEJ f AND 6. 1�A10 n11 soE . , _ Y; ,ry �. Z:;i! v COMSMCOONAMD SUETYSTANDARDS OVERHANG (6' OVEIMMG VAx CAW SDE OF 1AATi p ®�5� '•.; `�f r, p I ��� S STABLIPER PLATES ARE REOOIP£D ON SDE*ALL AI(C►NXtS ANO Ldtf7TlAtNk ANCHORS SET IN FLORIDA. SEE nWy RUE 15C. EFFECnW yARCH a 1499 un,•�,'•••• • �i :,�y4.�4� R�� E •?��, , JACOWEN HOMED x°N°dp ew °A�` v LETTER aLsc �ta�umgs uro oa��s ARE D.V. T. 12-1 f - O7 At. RtOF1T{rARx�1p ® P.O BOX 368 nk DRA G T1TLE T*= OF �Oae�k MAk�A�i� 510MR 'g'D °� NORV• SPACING TABLES SAFETY HARBOR. FLORIDA 34695 PHONE (727) 726-1138 ler MR fit) R�T13S m G mNr°ey°a"up gotr � °'°ts AD- TD-0087 - —. —. I ov 0 ADDENDUM SHEARWALL TIE-DAWN/PIER REQUIREMENTS vr. SA umm . . I". TWO PU SHEARII Aus (ALL SWAIM14) tc-00" NEWtRn Ur. S/w vDm _, , ". 3/1 ct"maK ftd Ix too ..mot 749 PIER M WWALLS (AL o1YAWQ X-Oft" IWW ampcdoR Mt a{ ROO 1� 5m NOTE 1 ut NOff 1 MOTE 1 SEE NOTE I"' SCE NOTES 2 AND I Q sf MOTH 2 AND I A A r" FEQb US LOCAT04 m FLep THIS L01'I1TON FO WrO IRS LOCATmx m I nb THS Lourai FIGURE 8.0 . FIGURE 8.1 THE DETAIL ABOVE IS SHOWN WITH A TWO PIER SHEARWALL CONFIGURATION, HOWEVER, THIS DETAIL APPLIES TO All SHEARWALL CONFIGURATIONS, ALL. ZONES. -AND ALL vI F VALUES. fRIAALMANUFAM rMPiTR=:1. 1 -CM1 tS WiA ft 9 VM WAX N-WW 71Ww NIT Ht L 7111 IR , PROVED BY VW Of K MAS DIOW AM QM FIZY= AT 10amw Awou iu w MTTD TtlR An UC1R n LIM w [7T7o 1� sel LOAD .�(j(�(j(SEE AO-A-Iaio+ [ro-00<9 ( tro1111 "R RM ar ctaiio AM n: uaU LLILTI � 1F •S,a �C-• F ••-� �'� 4 EB 1O mm.eno•;1L h3WL A M AT Eta DO ff TWL 9tC WL =5 rT1a; II M RTA�LI} 1N�. [AM KgMo AT CACH 00 CO JOISTS RECAtR1 M of iE-09M1 11N+�r k c !( S)'910334 1 �itA. TIfi MMWLL:; Lamw *mc A MIA tvm m IWIT 005-muffA no ! ��� _ * RED HOME K-PMW 3NAM CK pW AHS� RMAIMI (ALL 91 M4gL CMCW 71006 ALL TILES•o �Amx,Lc� Rw, �,.STATI~ CF�,�RMTgNANDWEWSTANDAROS JACOBSEN HOMES Tl�it anultvallo ...••'`'R.R. 02-01-00 ' OXAL �. P.O. tox Jaa 11ATa"S aF 4WM30;1:�M S/W TIE/PIER REQ. !Hc WCII tclWlK! w WETT tiMWK FLORIDA 31E05 REDRAWG 11A4":. PH OM (7z7j 720-113a Her aoabK uo Awl tm ORK • AD-TO-100 61 ADDENDUM DOUBLE SHEARWALL CONFIGURATION SINGLE SECTION TIE -DOWNS_ CIE)LLVO MAY BE FLAT OR SLOPED III END VIEW I { V MO PLF MAXWM 9JEARWALL DEVq.N VALUE (PER TAXI.) 11/4" x .o3s" TIE- ovm STRAP CONTINUCJS ARCJND JOISTS. DE VIEW X .035" TIE —DOWN STRAP UOUS ARLXW JOISTS. •�' :'illrr NOTES: i 7,171,1(p E J( (P�1RWAL: • :? t/L •�� DAPIA APPROVAL - GI t. A40*tS TO BE RAIED FOR AN ULTUATE LOAD OF 4775) (31W f7E8C11 LOAD) (SEE AD-ID-0:01 PD-GENERAL NOTES) FOR NOTES ON GROUND ANSIOR IvTALLAil01L) ' : 1 �_ APPROVED Big L KSTALL A PE.i AT EACH END OF THE 9CWALL JOISTS (PER THE ABOVE DETAILS): �_ OON 3. WICH SfAMrA`,L IS LOCATED ABOVE A SCUD 10DER (iUll WEIGHT CROSS-trD�9FP.) NO TEDOLL' STRAPS. OR PIERS ARE REED (ALL 94WWALL CONFICURAWV ALL 20NCS .� 1 � AND All WORM). 4. TIE-DOI STRAP REOUIRED AT EACH END OF JOISTS, ALL D8 PW CONFID?JRATIONS. �i . ' ' ' \\ �• S. CEILING SMOWN FLAT -OPT CArKORAL OR SLOPED CEAINC MAY BE USFD. t. s. 6. FULL WIDTH C. ��I, r;'L •: ��� i� 1• �' cocta:4MAresa:+-:-wxs�a SHEARWALt:S ARE SHOWN IN THE DETAL•ABOVE, HOWEVER RNYPL ENGTH OR ,% � ' �lrrnrr11111W"1 NFI CONFIGURATION SHEARWALL MAY BE USED. p JAOOBSEN HOMES S NOTICE: nrtst SPEOTICATIT DRAW BY: R.R DATE: 2-6-96 REV. LETTER: AN"oaAW S ARE 0rt"A� PIIOPRQAQY.!COIlUTNDAL DRAYANG nTIE: 5P,1prP.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 DATER ALS OF JACo0541 UANUFACTUR7ic eK ; NATIMALS ARE PROYM To nE WFI-I DBL. S W CONFIG. TIE —DOWN ORAv«\U NUMBO: AD—TO-0110 PHONE (813) 726-1138 T FOR SFUM Pl FMS k0 VJ5i LE K PT CaNN11 ffNRr1 AND mcuT n= OWNERS Liz CEILING WAY BE FLAT OR DOUBLE SHEARWALL CONFIGURATION TRIPLE & MULTI SECTIONS SIDE VIEW SIDE VIEW (MARRIAGE WALL APPLICATION) (SIDEWALL APPLICATION) 350 PLF MAXIMUM SHEARWALL DESIGN VALUE (PER WALL) 1 1/4' X .035" TIE -DOWN STRAP CON71N000S AROUND JOISTS. 350 PLF MAXIMUM SHEARWALL DESIGN VALUE (PER WALL) 1 1/4- X .035- TIE -DOWN STRAP CONTINUOUS AROUND JOISTS. M4 5 A TRIPLE WIDE RAFTER, I APPLICABLE TO STANDARD 9LE WIDE TRUSSES. 1D VIEW X .03Y TIE -DOWN STRAP JOUS AROUND JOISTS. NOTE: ALSO APPLICABLE TO 'SUP SW MARRIAGE WALLS %MEN AT LEAST 2 STANDARD VERTICAL TIES ARE INSTALLED. (1 EACH SIDE ADJACENT TO SHEARWALL LOCATION) NOTES: ENGINEER APPROVAL- DAPIA APPROVAL' I. (ROUND ANCHORS TO BE RATED F(R AN ULTIMATE LOAD OF 47251 (3150 DESIGN LOAD] (SEE AD-TD-DD01 [TD-CFNERAL NOTES] FOR NOTES ON GROUND ANCHOR INSTALLATION.) 2. INSTALL A PER AT EACH END OF THE SHEARWALL JOISTS (PER THE ABOVE DETAILS). APPROVED BY 3. WHEN SFEARWALL IS LOCATED ABOVE A SOUO HEADER (FULL HEDGIHT CROSS -MEMBER) NO TIED ALL STRAPS R PIERS ARE REQUIRED (ALL SHEARWALL CONDOURA7ION5. ALL ZONES f/ 1 4. TIE-DOW'H STRAP REQUIRED AT EACH END Cf- JOISTS, ALL DBL S/W CONFIGURATIONS John C. Doeden, 0TqP.E. 5. CEILING SHOWN CATHEDRAL OR SLOPED, FLAT CEILING LAY BE USED. L5133 C. R. 22 l; �;\ �. 6. FULL WIDTH SICARWALLS ARE SHOWN IN THE DETAIL ABOVE, HOWEVER. ANY LENGTH OR COUnGURATION SHEARWALL MAY BE USED. Goshen, IN 46526 o AT1oH Hwmiw�,ra 7. THIS DETA'L MAY APPLY TO TRIPLE AND/OR DOUBLE WIDE SECTIONS RdMOINAL. JACOBSEN HOMES BOX 368 SAFETY HARBOR. FLORIDA 34695 PHONE (813) 726-1138 NOTICE. THHESE sPECV1CA1fONS AND HNGNNCS ARE PROPRIETARY. AND CONEIDINTIAL MATERIALS OF JACOBSEN MANUFACttMC W_ %K H MATE A S ARE PR0no 10 THE RECMT rot SPEON PIMPM AND NMI K RPT CW WIIAL AND SECRET TROY OTIERS DRAWN BY: R.R. DATE 4—U9-96 REV. LETTER A DRAWINGP.O. � ` $/W CONFIG. TIE —DOWN DRAWING NUMBER: AD—TD-U] ] 1 .63 PORCH ANCHORING DOUBLE HEADED 3,1! NOTES: 1. SEE SET-UP MANUAL AND ADDENDUM FOR APPUCABLE BLOCKING X .035" TIE -DOWN STRAP JOUS AROUND STRAP 'BLOCXS. WINDZONE III EXPOSURE C (110 MPH) 20 PSF ROOF 10 PSF D.L. REF._'jCALCS.- c ;Vq 1049 at - DAPIA APPROVAL PPROVED BY 19INC. EDERAL MANUFACTURED HOME VON AND SAFETY STANDARDS N N SIP STRUC ,U NOTICE: DRAW BY: DATE:- RR LETTER: JACOBSEN HOMES Mg SPECMA706 AM WAVINGS AK M.T. 12-13-03 OMONA4 FRCPRUMY. AND CO*IMTM _3jAVANG TITLE: P.O. BOX 368 MAYMALS OF JACOBSEN MANFAMMC PORCH ANCHORING W_ Sm MATIMALS Aw mm" 10 im SAFETY HARBOR. FLORIDA 34695 KDPDfi rER SPEMIC PWM AND VMT BE DRAVANG NUIRR: m PHONE (727) 726-1138 KGn O0fV0flK AND CF3FT n= OHM AD-TD-01 12 64. ADDENDUM ALTERNATE VERTICAL TIE -DOWN APPLICATION FLOOR DIAGONAL FRAME TIE ANCHORING EOUIPMENT CAPABLE OF RESISTING THE WORKING LOAD REQUIRED ON THE TIE-DOWM SPACING TABLES (SEE OTHER DETAILS FOR TABLES) SEE OTHER DETAILS FOR ANCHOR ANGLE. APPROVED VERTICAL TIE -DOWN ANCHOR BRACKET (FACTORY INSTALLED) CRIMP SEAL (3150j WORKING LOAD) 6 d s x t 3 N J W La VERTICAL TIE -DOWN c TYPE 1, FINISH B. w GRADE 1 STEEL STRAPPING C 1 1/4- WIDE k 0.035- IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION 039S3-91. STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. RADIUS CLIP Im RADIUS CUP MUST BE INSTALLED ON ALL TIE -DOWN ANCHOR BRACKETS (INSTALLER TO FABRICATE RADIUS CUP BY PLACING A STRAWT 3- LENGTH OF 1 1/4- X 0.035- TIE -DOWN STRAP MATERIAL IN ANCHOR SLOT AND BENDING TO FORM THE CONFIGURATION SHOWN.) RADIUS CUP MUST BE INSTALLED TO PROTECT THE TIE -DOWN STRAP FROM THE BRACKET EDGES. INSTALL THE TIE -DOWN STRAP THROUGH THE SLOT IN THE BRACKET 'Qa r.(r THE RADIUS CUP. C. Doe',*,% .� 1PU OVANo. •. 'y DAPIA APPROVAL* NOTES: - :• ENES70357 ROVED BY 1. ALL VERTICAL TIE -DOWN STRAPS, DIAGONAL FRAME TIE -DOWN STRAPS AND ANCHORING EQUIPMENT SUPPL - Fell BY AND INSTALLED BY OTHERS- ON SITE. - T'.^.TF/��; � = .)l1N 1 5 19 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING - 0,�; •.• /, >r✓y!.' ��� SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- '.� !�`J J ..��� `�� ATI ON. '''���s,/ • • ....... `,``� INC rrnrAA<wwsAnlrmloli 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS �AA,,,,;NQL`,%%%`,,` caal,ucr°IN°wmaw� WHERE THE ANCHORING SYSTEM REQUIRES THE USE ANU10R SRTIE- OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CLIP). DEVICES ARE CERTIFIED BY OTHERS NO77CE: DRAWN BY.' C.L.Y. DATE: 5-31-95 REV. LETTER: JACOBSEN HOMES TKSE SK�,MS AW DRA1� ARE n 000mAL PROPwARY, AND OOII MTLAL DRAWING TITU: f-i mop MATERIALS OF 'ACMM MAIA,FACRAINO ALT. TIE -DOWN APPL. P.O. BOX 368 NC sxm umma ARE PRMEI TO THE SAFETY HARBOR, (813)F7261D 138,ti95 Wq CmW� P Ms� sm BEMM DRAWING NUMBER AC-TD-0200 65 ADDENDUM ALTERNATE VERTICAL TIE -DOWN APPLICATION FLOOR IF FACTORY INSTALLED STRAP IS NOT LONG ENOUGH. IT MAY BE LENGTHENED BY USNG A CRIMP SEAL WITH A WORKING LOAD OF 3150 POUNDS to 0 �w f �J e" DIAGONAL FRAME TIE r� --- II ANCHORING EQUIPMENT -III I CAPABLE OF RESISTING -I I V THE WORKING LOAD REQUIRED ON THE=I TIE —DOWN SPACING TABLES (SEE OTHER DETAILS FOR TABLES) I I,I II SEE OTHER DETAILS FOR ANCHOR ANGLE. NOTES: 1. ANY ADDITIONAL VERTICAL TIE —DOWN STRAPS. DIAGONAL ^ FRAME TIE —DOWN STRAPS AND ANCHORING EOUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS— ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REOUIRES THE USE OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CLIP). APPROVED VERTICAL TIE=DOWN ANCHOR STRAP (FACTORY INSTALLED) IF NEEDED. USE VERTICAL TIE —DOWN TYPE 1• FINISH B. GRADE 1 STEEL STRAPPING 1 1/4' HIDE h 0.035' IN THICKNESS. CERTIFIED BY A REGSTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91. STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. 910334 'a •• STATE tc� IAI �� s�-ON At��%/ JACOBSEN HOMES TNEsE sPEancAno s µ o MIRLS ARE ® ORIONAL PROPRIETARY. AND COfMDENTK ❑�� P.O. BOX 368 UATEMALS OF JACOBSEN UARA1TACTlRLNG INC. SUa MATERIU ,ARC NOW= TO THE SAFETY HARBOR. FLORIDA 34695 REONNT TOR SPEDFIC PJ OSES AND WSI BE PHONE (813) 726-1138 IVT CONFMrJA. AIO SEMET rROu oT1ET.S w EIS DAPIA APPROVAL_ APPROVED BY N1REVISED 14INCO nnasmuerinl AND sASFIr anwwnas DATE - REV. LETTER 10-os-9s n ALT. TIE -DOWN APPL. I /\ AD-TD-0210 66 ADDENDUM COLUMN TIE -DOWN APPLICATION COLUMN 'A' COLUMN 'B' SEE TABLE FOR MAxmUM SPAN FOR COLUMNS 'A' OR 13 COLUMN 'C' COLUMN V SEE TABLE FOR MAXIMUM SPAN FOR COLUMNS 'C' OR '0' I SEE TABLE FOR SPAN COL 'r SEE TABLE FOR MAX. SPAN FOR COL 'G' COLUMN 'E' COLUMN 'r COLUL94 'G' SEE TABLE FOR MAXIMUM SPAN•FOR COLUMN 'r MAXIMUM ALLOWABLE SPAN TYPE OF ANCNORK REOb (SEE AD-10-0251, COLUMNS 'A', V, V OR 'E' COLUMNS i3' OR 'G' COLUMN f AD-TD-0252 ANO ZONE 2 ZONE 3 ZONE 2 ZONE 3 ZONE 2 ZONE 3 AD-TD-0253) SEE NOTE 1 EXP. 'C, EXP. b' EXP. 'C' EXP. Tr EXP. 'C' EXP. V EXP. 'C Enp. V EXP. 'C' EV. 'D' EXP. 'C' EXP. 'D' 2 - 31501 ANCHORS 0-0' 29'-6' 33'-v 23'-7' 4S-O' 29'-6' 33'-9' 23'-7' 4S-V 29'-6' 33'-9' 23'-7" 1 - 31501 ANCHOR 21'-6' If- 9' W-10' 11'-10' 21'-6' If- 9' W-10' 11'-10' 21'-6' 14'-V 16'-10* 11'-10' I - +0001 ANCHOR 27-3' 18'-9' 21'-S' 15'-0' 21-3' 15'-9' 21'-S' 15-0' NOTES: ENGHEER APPROVAL• DMA APPROVAL: APPROVED 81(ALI�r 1. SEE AD—TD-0251, AD—TD'-0252 AND AD—TD-0253 FOR SPECIFIC INFO. ON ANCHORS. jm 1 5 2. SEE AD—TD—OD01 FOR ADDITIONAL NOTES ON ANCHOR INSTALLATION. �yr� 'NA INC Johi C. Doeden, 15133 C. R. 22 Goshen, IN 46526 JACOBSEN HOMES NOW& xsE vmrca1Ns Av Dm-m DRAMM BY: c.LY. DATE: 5-31-95 REV. LETTER mmnmom PRavwmy. me COW OMOL ORATING TIM COL TIE APPL. \I P.O. Box 36B MATMALS OF .M USEN MANWACTIAw NC WW MAIEIW ARE PROUOED TO THE —DOWN DRANIIG NUMBER: AD—TD-0250 SAFETY HARBOR.. FLORIDA 3095 RTmW ►OR WE= RffM NO IWT 9E PHONE (813) 726-1138 PVT aWWWL AND SEOV FROM CTMM 67 , ADDENDUM COLUMN TIE -DOWN APPLICATION ANCHORING EQUIPMENT CAPABLE OF RESISTWG THE WORKING LOAD OF 3150 / MIN. O ANGLE SHOWN. MARRIAGE LINE OF MULTI -WIDE FLOOR „ FLOOR la VERTICAL TIE -DOWN TYPE 1, FINISH B. GRADE 1 STEEL STRAPPING 1 1/4' WIDE k 0.035' IN THICKNESS. CERTIFIED BY V A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION 03953-91. STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL, AND SEALS. �TI—=1 T I�TINN �III III_ _I I.II ANCHORS INSTALLED 24' APART COLUMN STRAPS SEPERATE GROUND ATTACHED ANCHORS 3S ANGLE TO TWO (3150# EA. NOTES: F NOYALv(JL�On%�'' ``` C DAPIA APPROVAL• 1. ALL ANCHORING EQUIPMENT SUPPLIED " •.• ` G�STER ,: FO'? �� BY AND INSTALLED BY OTHERS- ON SITE. Q� N0. AFr=;C`vED BY , 2. ANCHORING EOUIPMENT EXPOSED TO WEATHERING _ ENE8703571 SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- ' 5 19 ATION.V 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REOUIRES THE USE '• •�`•'• INC, OF EXTERNAL STRAPS OR CABLES. '��Ff '• aDanucrlauostr •... •• y(j�`�.` JACOBSEN HOMES11 ■ P.O. BOX 368 „ NOTICE 1Nese sKQnCATMS AM MUM AMC.L.Y. 010aNAL PRQVVAR7. AND CCNiIDOITIAI UATOaA3 OF aCOM 114"ACAMC vNANn nr: uAlt 5-31-95 MY. u 11tK A /` DRAWING TITLE: COL. TIE —DOWN APPL. SAFETY HARBOR, FLORIDA 34695 A10P00 MR_ A9W FLOM MO I0157 IIE '/�\ DRAWING NUMBER: PHONE (813) 726-1138 M" COI WPAL NO SECIET MW OMM AD-TD-0251 6$ ADDENDUM COLUMN TIE -DOWN APPLICATION FLOOR ANCHORING EQUIPMENT - CAPABLE OF RESISTING THE WORKING LOAD OF 3150 1 LON. I*] MARRIAGE LINE OF UMn-W.DE FLOOR VERTICAL TIE-DOMM TYPE 1. FINISH B. GRADE 1 STEEL STRAPPING. 1 1/4- MADE & 0.035- IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91. STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. COLUMN STRAPS ATTACHED TO A SINGLE GROUND ANCH,O,R,,.(3150#) NOTES: 1. ALL ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS- ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES. JACOBSEN- HOMES P.O. Box 368 SAFETY HARBOR. FLORIDA 34695 xprdPHONE (813) 726-1138 5� Q�G` No. 9Fp - • !Ir01 c C y %S/ONAL N017CE THESE STEOMIUITOIS AND ORANNGS ARE ORIODIAL PROPRIETARY. AND CONiDD114L MATERIALS OF JACWSDI MNAJFACTUWG NG SI01 MATOWLS ARE PRONGED TO THE REaPOR rOt 5PECr1C PI1iPOSTS AM MW BE WK COWMIIAL AND SECRET 110 OrM& BY. BY A, Jkm 1 5 1�95 INC C.L.Y. I - 5-25-95 COL TIE -DOWN APPL. It AD-TD-0252 69 ADDENDUM COLUMN TIE -DOWN I,I FLOOR i ANCHORING EOUIPMENT p CAPABLE OF RESISTING O THE WORKING LOAD p 0 OF 4000 0 MIN. APPLICATION MARRIAGE LINE OF MULTI -WIDE FLOOR VERTICAL TIE -DOWN TYPE 1. FINISH B. 'GRADE 1 STEEL STRAPPING 1 1/4" WIDE & 0.035" IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL. AND SEALS. COLUMN STRAPS ATTACHED TO A SINGLE GROUND ND ANCHOR (4000#) ,III111I1I NOTES: ENOREEF� DpF ���i DAPIA APPROVAL - 1. ALL ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS- ON SITE. Q� Np• �O't� fAPPROVED BY, 2. ANCHORING EOUIPMENT EXPOSED TO WEATHERING N� - E SHALL HAVE A RESISTANCE TO WEATHER DETERIOR= c 87 5'^ ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS -: r4 A INC WHERE THE ANCHORING SYSTEM REQUIRES THE USE ��0� O�[ OF EXTERNAL STRAPS OR CABLES. ',, �`'•• p► •'�a��claelos+rOtswaua ��•,,, spa • • ' ty �,,� NOMC& DMTHNB . DATE REV. LETTER: JACOBSEN HOMES OICJA111>r15 AM DRAMs ME C.L.Y. 5-25-95 OlMiAL. PROPp>CTARY, Also calrl "Im DRAWING ITLE P.D. Box 368 NATMALSi of JAC085EN UAMNACM UC COL. TIE —DOWN APPL. „ SAFETY HARBOR. FLORIDA 34695 eEr ray PEEcnsc ! AW AK FRDMOTO K DRAWING MNBER PHONE (813) 726-1138 107 Ca:oE IPA AM mm ma mom AD-TO-0253 70 ADDENDUM 184" WIDE COLUMN TIE -DOWN APPLICATION 'A' COLUMN *a' fCal= ISEE TABLE FOR 11AWAI SPAN FOR OOLUMHS'A' 0R r I 'CCOLUMN b\ �cmum J APPROVED BY ISEE TABLE FOR 11AXIIAN SPAN FOR COLUMNS 'C' oR b' SEE TABLE FOR SPAN COI. 'E' SEE TABLE FOR UAK SPAN FOR C0. I I V C. FED LMANUFACTUREDFlOklE RUCTIONAND SAFETY ST0OAP.0S MAR 0 3 1999 /MMMH 'r /cmum *r cawN 'C N SEE TABLE FOR MAW N SPAN FOR COLUMN i ' _ r MAXIMUM ALLOWABLE SPAN TYPE OF ANCHORING REOb (SEE AD-TO-101. COL.UYNS'A'.'C. V OR E' CIA IUIS'B' OR V cmw �• AD-70-M2 AND AD-71)-104 ZONE 2 ZONE 3 ZONE 2 ME 3 ZONE 2 ZONE 3 SEE NOTE 1 W. 'C' EXP. V ETD'. 'C Ems. V EXP. V OP. V DE V DP. V EXP. 'C EXP. V EW. 'L' EXP. V 2 - 3150J ANCHORS 3Y-4' 25-6' 29'-4' 20'-4' 3r-4* 25W 29'-4' 20'-4' 37-4' 25W 29'-4 21Y-4' 1 - 31501 ANCHOR Iff-6' 12f-16' 14-7' 10'-3' 18'-6' 12'-10' 14'-7' 10'-3' 18'-6' 12'-10' 14'-r 10'-3' 1 - 40001 ANCHOR 23-8' 16'-4' 18-7' 13'-0' 23-B' 16'-4' 18'-7' is -or 23'-6' 16'-4' 16'-7- 13'-O' REF. CALM C %✓ 93 o NOTES ENa ....• Fz �� c,�STER�c • e '4 DAM APPROVI�s{Z Io1rN� 1. SEE AD-TD-0251, AD-TD-0252 AND AD-TD-0253 C�Q:•• ;'Q� N0. O ••• APPROVED BY FOR SPECIFIC INFO. ON ANCHORS. - 910334 .� 2. SEE AD-TD-0001 FOR ADDITIONAL NOTES ON ANCHOR INSTALLATION. � * ' - OF �: STATE ` INC JACOBSEN HOMES NOTIC@ V wm sKanuTm mm DRamcs MC ORA Y: M.T. DATE: 2-9-99 REV. LEnm DRawtr+c nu: 1$4" WIDE COL. TIE -DOWN APPL. DRIaNA- PROPRKiABf. AND OOMF�NTUL MATEMALS OF JACU85£N M MlFAC1URNG=No P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 MNc SUCH RATIRALS ARE PROMM TD THE REapmT Put Sian Mir rm no wst tK ORAYANO NUMBER: AD—TO-0254 PHONE (727) 726-1138 KEPT aamDDIM AND SW FROM CUM 79 ADDENDUM TYPICAL SINGLET' WIDE TIE -DOWN PLACEMENT SEE NO1E 2 A B C 24' LARGE OPENING 24' SEE NOTE 1 JIMUARU VMIIU%L IIL-LPtJM MArb U( ANUM BRACKETS (SEE TIE -DOWN SPACING TABLES -NMM AND/OR ALTERNATE- FOR h1A)0 N SPACING ALLOWED). ALSO SEE NOTE 3. STANDARD VERTICAL TIE -DOWN STRAPS OR ANCHOR BRACKETS TO BE INSTALLED A NAI mm OF 2'-0* (241 FROM EACH END OF THE UNIT. NOTES: EN PR O •, y DAPIA APPROVAL I. LARGE OPENING =ANY OPENING WIDER THAN NAX TIE -DOWN SPACING ALLOWED.- EN22:8703571 �. 2 VERTICAL TIE -DOWNS MAY EXCEED THE STANDARD VERTICAL TIE -DOWN SPACI • -•- - ROVED BY SO LONG AS, THE AVERAGE SPACING [ (A+B+C) 13 ) DOES NOT EXCEED THE MAXIMUM TIE -DOWN SPACING REQUIRED ON THE APPROPRIATE VERTICAL/FRAME ,�'•. /� �,. ' �'ii� AW 1 5 MIS TIE -DOWN SPACING TABLES (SEE 07HER DETAILS).. 3. INSTALL FRAME TIES Ff '' • . I , , • •' v\```�� °-�.,s�or1AL1�,EN,,,�� INC, AT ALL VERTICAL TIE -DOWN LOCATIONS. 4. SEE AD-TD-0001 FOR ADDITIONAL REOUREYENTS .:•_���, .:�:`r;cv flySk' " ANCHOR BRACKET AND TIE -DOWN DEVICES ARE CERTIFIED BY OTHERS JACOBSEN HOMES IN077CE 1HEsE sKancom AND DRAwo ARE DRAWN On C.L.Y. DAIS 5-31-95 REV. 1ETU: P.O. BOX J68YATERIAlS MONAl, PRO "ETM . AND COE=TK OF UANNAMUGDRAWwc YATE0 PROMSPJFM ) TO TOE A nTI�SINGLE WIDE T/D SAFELY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 REO EK �M�/ p 4OV FRW pRM ��G Musm AD—TD-0300 72 ADDENDUM TYPICAL MULTI- WIDE TIE -DOWN PLACEMENT SEE NOTE 2. A B C 24' LARGE OPENING 24' SEE NOTE 1 COLUMN SUPPORT DE -DOWN STRAPS REQUIRED AT COLUMN LOCATIONS ON EACH SIDE OF OPENINGS GREATER THAN 43' IN MOTH. MULD-WIDE FLOOR SHOWN SEPERATED FOR CLARITY v 6! L24' L24' STANDARD VERTICAL TIE -DOWN STRAPS OR ANCHOR BRACKETS (SEE TIE -DOWN SPACING TABLES -NORMAL AND/OR ALTERNATE- FOR HAWN SPACING ALLOY O). ALSO SEE NOTE 3. STANDARD VERTICAL TIE -DOWN STRAPS OR ANOIOR BRAD(En TO BE INSTALLED A MAXIMUM OF 2'-O' S24' FROM EACH END OF THE UNIT. FOR TRIPLE WIDE AND LARGER UNIT DESIGNS, INSTALL 00,111111 ALL TIE -DOWN STRAPS AS SHOWN IN THIS DETAIL ,.��`` N C. NOTES: . 4A)-� • FO.'!!j �� DAP1A APPROVAL • fY I. LARGE OPENING = ANY OPENING WIDER THAN MAX TIE -DOWN SPACING ALLOWED. JENE8703571 = OVED BY 2. VERTICAL TIE -DOWNS MAY EXCEED THE STANDARD VERTICAL ME -DOWN SPACI , SO LONG AS, THE AVERAGE SPACING [ (A+B+C) / 3 ] DOES NOT EXCEED THE TA OF MAXIMUM TIE -DOWN SPACING REOLRED ON THE APPROPRIATE VERTICAL/FRAME ���'. ( !� ��.� 1 5 W TIE -DOWN SPACING TABLES (SEE OTHER DETAILS). %'�F ' .ti. • �qN . •''�a ��` I V 3. INSTALL FRAME TIES AT ALL VERTICAL TIE -DOWN LOCATIONS. �'�''i`r��IVAL E�G````�� 10`""ra"O1iroyarriwoww 4. SEE AD-M-0001 FOR ADDITIONAL REQUIREMENTS At+LSi6Ne8!!>IIiT1AT1a 11E-DOWN DEVIO5 ARE CLRYWMU er OTHERS N017C� DRAWN BT: DATE REV. LETTER: JACOBSEN HOMES TASE SVEonu , aeETAer Daa #XD DUUWZ fxE C.L.Y. 6-1-95 omomVaoAM 000WIM DRAWING TITLE m P.O. BOX 368 YATERIAIS °f'""WATUMS AK PR%W TO THE uauFAcluanc TYP. MULTI-1MDE T/D SAFETY HARBOR. FLORIDA 34695 DL�IpQ�;( Fot 9M RInO NO 051 BE DRAWNG NUMBER: PHONE (813) 726-1138 I VT MWMna No SE= "M ODIUM AD-TD-0310 T3 ZONE I TIE -DOWNS SEE DETAIL — 'A' SEE DETAIL — V SINGLE WIDE TIE -DOWN MARRIAGE WALL OPENING TIE —DOWN IEQUIRED AT OPENINGS ONLY. OPTIONAL AT OTHER LOCATIONS.) I FRAME TIE —DOWN DOUBLE WIDE TIE -DOWN NOTE: C SECTION 8 MARRIAGE WALL SIMILAR TO I OPENING TIE —DOWN 1 SINGLE WIDE p (REQUIRED AT OPENINGS FRAME TIE —DOWN � ONLY. OPTIONAL AT OTHER LOCATIONS.) IATR PULL DOWN TIGHT TO --/ GROUND ANCHOR DETAIL 'A' I NOTE: A k B SECTIONS SIMILAR TO DOUBLE WIDE TIE —DOWN TRIPLE WIDE TIE -DOWN BUCKLE WITH 2O251 TY MwimuM SEE DETAIL — 'A' SEE DETAIL — V TIE -DOWN STRAP SINGLE HEADED GROUND. ANCHOR (WHEN MARRIAGE WALL TIES AND FRAME TIES ARE LOCATED AND SECURED TO THE SAME GROUND' ANCHOR, A DOUBLE HEADED GROUND ANCHOR MUST BE USED) ALL GROUND ANCHORS MUST BE LISTED TO CARRY THE LOADING IMPOSED BY THE TIE -DOWN STRAPPING (3150 LBS. MA)aMUM FOR EACH TIE -DOWN STRAP CONNECTED). DETAIL 'B' 0 TYPICAL TIE -DOWN STRAP (1 1/4' X .035' MINIMUM LINK COATED STEEL STRAP, OR EQUAL WITH 31So; CAPACITY MINIMUM) K l.'S- 47zs 40 uLTIr wrvr LOAN.O oqrArITy NOTES: ENQNwAw 1. SEE DETAIL 13' PAGE 4 NOR MARRIAGE WALL ,� >O•�,�T't1�ICg1 OPENINGS GREATER THAN 49 INCHES. & VP To 1"7T-6" I)ei SvTq�y 2, SEE TIE -[TOWN SPACING CHART ON PAGE 2 �R s PAS.:. ND• C�4S45i ANCHOR AND TIE -DOWN PLACEMENT. 3. SEE DETAIL 'A' PAGE RDR TYPICAL I -BEAN PIER CONSIT2UC110N STATE OF i F •'•,! t0FllDQ; DAPIA APPROVAL: APPROVED BY !�.._ DES 2 1N' N II Va �}y�'1141A1O NiNET'T" E6T ." JACOBSEN HOMES THESE SPEaRCADONSS MW ORAVUIM ARE 71- DRAWer. TE RR °A 10-31-95 REV' . OFOUNAL PROPRIETARY. AND CCNFMTUL DRAMNG TITLE - MATERIALS OF JAC08gN MANLWACTMC P.O. BOX 368 INC. M UATERLA s ARE PROVIDED TO THE ZONE I TIE —DOWNS SAFETY HARBOR, FLORIDA 34695 REMENT FOR SIM RIPMS Me Iasi K DRATHNG NUMBER PHONE (813) 726-1138 IVT CONFIDENTIAL MO SEOtLT fF= OHM AD-Z1-0001 74 75 76 ZONE 1 INSTALLATIONS 1. FOR HOMES LOCATED IN ZONE I, FOLLOW THE MANUFACTURER'S ZONE 2 INSTALLATION INSTRUCTIONS FOR THE INSTALLATION OF LONGITUDINAL ANCHORS. 2. FOR HOMES LOCATED IN ZONE I ONLY, FOLLOW THE MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR THE INSTALLATION OF SHINGLES AND/OR LAP SIDING. FOR ALL OTHER WIND ZONES REFER TO DETAILS IN THE SET-UP MANUAL AND/OR THIS ADDENDUM. BY aCd" FEB 0 1 M INC. NOTICm I.—P. ... �. I. —1—OD —.. __.__... JACOBSEN HOMES 1n9` >TOd AND DRABARE n GRCK4L IROPMARW AND CV*W VIAL DRAWING 111LE: t1 P.O. BOx 368 MAWRIALl OP 1►NC. Ca UV MANNACWURMO ZONE 1 INSL wN MaRNAU ARE PPWKC TO 1ME SAFETY HARBOR. FLORIDA 31595 P uwa ram V= rj"o Am SAW R DRAWING NUMBER. PHONE (727) 726-1138 lof couLom AO Km rRar coats - AD-Z1-0100 77 ADDENDUM FOR INTERSECTING UNITS MAIN UNIT /DORMER I \ LONGITUDINAL TIES ONLY REQUIRED 0 EA HALF OUTSIDE BEAM THIS END, EXCEPT FOR ZONE 3 EXP. '0' THEN 2 REOUMD EA HALF (IE ONE EA. BEAM, ETC_.) VERTICAL AND DIAGONAL TIES INSTALLED ALONG THE SDEWALLS SAME AS THE MAR! UNIT. VERTICAL TIES AT CENTER LINE REQUIRED ONLY AT COLUMN SUPPORTS PER DOUBLE MADE COMEC71ON REOUIREMENTS. 24' MAXIMUM SPACING TO FIRST SIDWALL TIE FROM EACH END OF THE UNIT (SAME AS TYP. DOUBLE WIDE TIE —DOWN REQUIREMENTS). 2 LONGITUDINAL TIES REWIRED AT EACH HALF TNS END ONLY. MAXIMUM PIER HEIGHT FOR VARIOUS ZONES (REFER ALSO TO SIDEWALL PE —DOWNS MAXIMUM HEIGHT} ZONE 2 70w EXPOSURE •C' 90, 56. EXPOSURE V 39" 46• CONNECT THE TRIPLE WIDE OR QUAD. WIDE SECTION(S) TO THE DORMER AND MAIN UNIT PER DOUBLE WIDE MARRIAGE IJNE DETAILS AS OUTLINED IN THE SET—UP MANUAL (EXCEPTION: NAILING ONLY IS REQUIRED AT FLOOR CONNECTION, NO STRAPS ARE REQUIRED TO BE INSTALLED ACROSS THE FLOOR CONNECTION AT THIS AREA.) ````���11T11111IUU��'''i NOTES:E RDSAE •, �i RF •' DAPIA APPROVAL 1. FOR QUAD SECTIONS. EACH DOUBLE SECTION' OF THE UNIT SHALL BE DESIGNED >�•••�G • 2 � Q` N0. O % •/ENEA70357 APPROVED BY�„r. INDEPE► DENT OF THE OTHER STRUCTURE (IE SHEARWALLS, TIE —DOWNS, RIDGE— ; '• BEAMS, COLUMN SUPPORTS, ETC... ARE CALCULATED FOR EACH MULTI —SECTION.) _ -- AN 1 5IM Aply F.•��,, INC c�mtic+4�A•Owrnswovao 1s�?�`���`• JACOBSEN HOMES NOTICE. THESE sPEanunoNs AND DRAtlN4S ARE DRAWN BY: C.L.Y. DAIS 5-16-95 REV. LETTER: DRAWING TITLE -TNT. UNITS P.O. BOX 368 neONAL PROPRIETARY. AND CON)IDOMAL MATMMS OF JACOM MURW M"ACIC „ SAFETY HARBOR, FLORIDA 34695 W. M MATERWS ARE PRONOM TO NEADDENDUM RECPFM rot FECFIC Pt✓Rt M kO MUST K DRAWING NUMBER PHONE (813) 726-1138 ei cwm Lq AND sEav rRow am OUADADDI 78 ALT. ROOF ASSEMBLY FOR MULTI- WIDES CENTERLINE CONNECTION FOR OUAD UNITS IS THE SAVE AS FOR THE MAIN UNIT (REFER TO SET—UP DETAISj NOTES: 1. 30 GA. GALV. STRIPS USED MAY BE WAND DEFLECTORS REMOVED FROM ROOF IN ORIGINAL CONDITION (EXCEPT FOR STAPLE HOLES). STEEL STRIP MAY BE CONTINUOUS OR PIECED. 2. SHINGLES IN THE DORMER AREA OF THE MAIN UNIT MAY BE SNIPPED LOOSE AND INSTALLED ON 91E AFTER THE UNITS HAVE BEEN ATTACHED 10 PREVENT ANY TRANSIT DAMAGE AND TO ENSURE THE SINGLES LINE—UP FROM ONE SECTION TO THE NEXT. 30 GA. GALV. STEEL STRIP INSTALLED OVER HATING LINE JOINT (SEE PLAN NEW BELOW) 30 GA. GALV. STEEL STRIP 8' X LENGTH OF ROOF SSECDONS MAY BE OVERLAPPED 2 MDR.) W/STAPLES AS SHOWN. INSTALL ROOF CAP PER SET— UP MAN. OVER GALV. STRIP. (SEE NOTE 1) 30 GA. GALV. STEEL STRIP SECURED WITH 7/16' X 16 GA. STAPLES FULL PENETRATION INTO DECKING 2 " D.C. MAX SPACING (TYP.) ... ustill Or • �\STER•`UF No. $46 ;• ENE8703571 ss.......... . 31 X S' LAG SCREWS IB' O.C. (ZONES 2 & 3) STAGGERED DAPIA c7 BY .�)N 1 5 -M *14 LNG NOTICE: —118 ILfNWvr: ] UAR: n"' L"'n: JACOBSEN HOMES msE vEonumm AND ORAN= ACE C.L.Y. 5-16-95 OfEONAL. PKMTANY. AND CIV nIDITUL DRAWING TITLE: OppP.O. BOX 368 MAITIIALS OF .IACOSSEN MAAIFACTURWG ALT. ROOF ASSEMBLY RUC SIM MAZIMS ARE PROVM TO THE SAFETY HARBOR FLORIDA 34695 RECPENT FOR 9W PIAP= NO MST EE DRAWING NUMBED PHONE (813) 726-1138 KLPT CONMTLAL AO SEm INCH ones QUADADD2 79 JACOBSEN ��HOMES 600 PACKARD COURT 11 SAFETY HARBOR, FLORIDA 34695 (727) 726-113 8