HomeMy WebLinkAboutWIND SPEED & EXPOSUREKING CARTER
Applicable Codes, Regulations, and Standards
1. The 5th Edition (2014) Florida Building Code, specifically Chapter 16 Structural
Design, Chapter 20 Aluminum, and Chapter 23 Wood.
2. AA ASM 35 and Specifications for Aluminum Structures, Part I -A of the.
Aluminum Design Manual prepared by The Aluminum Association, Inc.
Washington, D.C., 2005 Edition
3. ASCE 7-10.
Wind Loads
1. Building Occupancy Category, Paragraph 1604.5 and Table 1604.5:
Risk Category 1.
2. Basic Wind Speed, Figure 1609C, State of Florida Debris Region & Basic Wind
Speed, Paragraph 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed:
VULT =150 MPH, VAST) =116 MPH
3. Exposure Category, Paragraph 1609.4.3: Exposure B
4. Building Category for Aluminum Structures, Paragraph 2002.6: Building
Category 1- Carport- Non -Habitable, Unconditioned
Roof Type
1. Roof Type: • MONOSLOPE
2. Roof Material: 3" x 48" x 0.032" composite panel Elite 2000,1.0 density
foam, Florida Product Approval Number FL 7561-R3. 952-R1
Foundation Design
Existing concrete. No additional concrete footing or slab is required to resist the
loads imposed upon the existing slab by the proposed construction if the existing
slab is a minimum of 4" thick and in sound condition, free from structural
cracking, spalling, or other deterioration.
Specifications
The following specifications are applicabl6 to this project:
1. All work shall be in accordance with the Sth Edition (2014) Florida Building Code,
and.any other applicable local codes and regulations.
2. Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, no
manufacturer substitution is acceptable without the specific written, signed and
sealed authorization of Suncoast Aluminum Engineering, LLC.
3. Screen Material: Design based on 18/14 or 20/20 Better View. Any other material
must be approved.
4. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better
zinc plated to ASTM B633, or coated stainless steel series "300", or uncoated
stainless steel series "400".
5. All Self Mating Beam Sections are to be stitched with either # 14 screws 6" from
ends and 24" center to center or #12 screws 6" from ends and 12" center to center.
6. Where concrete specifications are required, whether in the screen enclosure scope
or not, by one or more regulatory agency, the following specifications are
applicable:
a. Concrete shall conform to ASTM C94 for the following components:
i. Portland Cement Type I,- ASTM C 150
ii. Aggregates - Large Aggregate 3/4" max - ASTM C 33
iii. Air entraining +/- 1% - ASTM C 260
iv.Water reducing agent - ASTM C 494
v. Clean Potable water
vi. Other admixtures not permitted
b. Metal accessories shall conform to:
is Reinforcing Bars - ASTM A615, grade 60
ii. Welded wire fabric- ASTM A185
c. Concrete slump at discharge chute not less than 3" or more than 5". Water
added after batching is not permitted
d. Prepare and place concrete per American Concrete Institute Manual of
Standard Practice, Parts 1, 2, and 3 including hot weather recommendations.
e. Moist cure or polyethylene curing permitted.
f. Prior to placing concrete, treat the entire subsurface area for termites in
compliance with the FBC.
g. Concrete shall be placed over a polyethylene vapor barrier.
h. All aluminum components embedded within concrete shall be coated with a
bituminous paint or epoxy.
7. All flashing and weatherproofing shall be provided by the contractor.
8. Door location shall be determined by contractor in the field.
9. Use of these plans acknowledges and accepts a limit of liability not to exceed
design and engineering fee.
WIND SPEED AN: ' "POSURE HAVE
BEEN DETERMI ,, _ JSING THE ADVANCED
TECHNOLOGY COUNCIL'S WEBSITE
AND GOOGLE EARTH.
.o
i
3X3XO.093
POST
3X3X0.093
POST
c
�
L
I
THESE PLANS Al' dD ALL PROI"OSED ky.0RK
l ARE SUBJECT TO ANY CORRECTIONS
RErrQppUIRED BY GELD INSPECTORS
�THAT
q0tKY Uffl H
File Copy
% .. .•• /'I �i
• 4 cr
.0 o E-�.y
a: co w o- J
cc k
J \
A 1 _fU'1F_ 063 1 '1�&A- * TF-1
S 7. LUC7, C0L7, �T17Y R UEDE� r TtqSY 1N
DATE 3
PLAINS AT NW �Pt_R_1'a'H-sc��`EUST BE `- :PT ON JOB
ILL BE P,
CONCEALED PAS i PNPNS OR ATTACHMENT 6
ARE THE RESPONSIBILITY OF THE
CONTRAOTOR OF RECORD
13'-6'
P 13'-7-
=3
4TH WALL
BEAM
m
2X5SMB
EDGE BEAM
2X3
A-2 ENDi�BEA
ZXSSMB o d,
rINT BEAM [mod
A-2 o$
2X5SMB •Nod 2X5SMB
rRIDGE BEAM cLLd EDGE BEAM
A—Z n c
L 1'-0-
I12'-0' . 13'-6' �I. 13'-7' +r
3=0.093
POST c
I
0 33X0.093
PST
J I I
❑ 0
W
O ui d
W d
a � m
LL ( iiiZLLL $
'..
CC en enm am
W �N 4.=
W Z t/1 Z
Z Lu �
U' W> Oz7
W tt; H �
Z CV
J �
� N
/I
F— Z " s cc
N CC tmo8
O W
Z EE��
Z tt 5 Z
N W M ud12
N]
CA
W Z
o g
Q u1
00 U
J
UJ��U)Ln
23m
cn�t`.�
a W NarJL
TP
DATE DRAWN
08/18/17
REVISION
SHEET NO:
I
m
ii
Z
U
A-1
ALUM&UM MEMBERS DIMENSIOP"
HOLLOW SECTIONS
2 x 2: 2" x 2" x 0.046"
2 x 3: 2" x 3" x 0.050"
2x4: 2"x4"x0.050"
2 x 5: 2" x 5" x 0.050"
OPEN BACK SECTIONS
_ 1 x 2: 1" x'2" x 0.040"
1 x3: 1"x3"x0.045"
SNAP SECTIONS
2 x 2 Snap: 2" x 2" x 0.045"
2 x 3 Snap: 2" x 3" x 0.050"
2 x 4 Snap: 2" x 4" x 0.045"
SELF MATING (SMB)
2 x 4 SMB: 2" x 4" x 0.044" x 0.100"
2 x 5 SMB: 2" x 5" x 0.050" x 0.100"
2 x 6 SMB: '2" x 6" x 0.050" x 0.120"
2x7SMB: 2"xT'x0.057"x0.120"
2 x 8 SMB: 2" x 8" x 0.072" x 0.124"
2 x 9 SMB: 2" x 9" x 0.072" x 0.124"
2 x 10 SMB: 2" x 10" x 0.092" x 0.398"
MINIMUM FASTENER EDGE DISTANCE: 1/2"
MINDAUM FASTENER SPACING: 3/4"
CONCRETE SCREW ANCHOR:
SHVIPSON TITEN HD OR EQUIVALENT
SHEET METAL SCREWS (SMS):
ITW / BUILDEX OR EQUIVALENT
#14 x 4 7/8" SMS W/
1 1/2" DIA. NEOPRENE
FACED WASHER @ 8" O.C.
3/8" DIA
THRU BOLT I
2'x5'SMB E
I !
Wx3"x0.093'
POST
COMPOSITE PANEL
1 112"x2118"x 1 1/2" x 0.062" x WLONG
ALUM RECEIVING CHANNEL W/ (3)
#14 x 3/4" SMS EACH SIDE OF
BEAM & (2) 3/8" DIA. THRU BOLTS
INTO POST
S-1 OMPOSITE ROOF TO POST INTERIOR CONNECTION
A-2 SCALE: NTS
x 3" x 0.093"
(2) 3/8" DIA. CONCRETE I I
SCREWANCHORS
(3" CONC. EMBED) t INTERNAL/EXTERNAL
I 3" x 3" x 1/8" EXTRUDED
j /-POST BASE W/ (2) 3/8"
f / DIA. THRU BOLTS
4
a \3" x 3" POST TO CONCRETE CONNECTION DETAIL
/� -n
SCALE: NTS
#14 x 4 7/8" SMS W/
1 1/2" DVLNEOPRENE FACED
WASHER @ 6" O.C.
FLASHING
3" COMPOSITE
ROOFPANEL
END • '
I • END
BEAM •
; • BEAM
1 1/2" x 21 /8" x 1 1 /2" x 0.062" x 3" LONG
ALUM RECEIVING CHANNEL W/ (3)
318" DIA #14 x 3/4" SMS EACH SIDE OF
THRU BOLT j BEAM & (2) 318" DIA. THRU BOLTS
INTO POST
2"x5'SMB
3" x 3" x 0.093"
I I POST
S-2 COMPOSITE ROOF TO RIDGE BEAM CONNECTION
A-2 - SCALE: NTS
#14 x 4 7/8"SMS W/
1 1/2" DIA. NEOPRENE -
FACED WASHER @ 8" O.C: -
3" z 0.062" ALUM
RECEIVING CHANNEL
W/ #10 x 3/4" TOP AND
BOTTOM AS END CAP
3/8" DIA
THRU BOLT
2"xYSMB
3" x 3" x 0.093"
a� copy
COMPOSITE
)OF PANEL.
LL i
-c
o o= J-
PROF
llllltll
SSIONAL SEAL
1 1 /2" x 21/8" x 1 1/2" x 0.062" x T LONG
ALUM RECEIVING CHANNEL W/ (3)
#14 x 3/4" SMS EACH SIDE OF
BEAM & (2) 3/8" DIA. THRU BOLTS
INTO POST
S COMPOSITE ROOF TO POST CORNER CONNECTION
A-2 SCALE: NTS
W COMP ROOF
2" x 3" x 0.050"
KNEE BRACE
•
•
11121 x 21/8" x 1 1/2" x
0.062" x 3" LONG ALUM
RECEIVING CHANNEL W/ (3)
#12 x 3l4" SMS EA. FACE &
(3) #12 x 39' INTO POST
BEAM
S-3 KNEE BRACE CONNECTION DETAIL
A-3 SCALE: NTS
❑ 1!1
C
cl
w
Ld
C
Ld d
W
a
O1 yi j
i
u
11.
(D8 Z0 cc
0m
a
cc
am
LLI
W
0-2
(A :3
Z
-m aaC'm
5
W Z G Z
W u O u
Z
W
tt;
C
c
a
0
c
Z
5
U
fi
0
Q Z og
u
= k
_
zroeo
N cc IvmBS
$
;� g
Q W W , G1 cp
W� mm
zU 1
O�y
Z f i
f
U � Q N N
= f
Z U' 'n3^^
p 1
m Z
VI W .miu lW-u
u
N
N W
c g
� W
a 2�
co J
WtE I co L
Lu
OO�
n. It N O- LL
TP
DATE DRAWN
08/18/17
SHEET NO:
A-2'