HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTS-, File COPS',
RE(-- A!VED AUG 2 J'7.017 -
i
BC15 Home k tog In User Registration. Hot Topics Submit,Surcharge ', Stats & Facts ; Publications ` FBC Staff ( BCIS Site Map Links 1
Fitxi a CONUALED FASTENERS OR ATTACHMEN'i
Prodr " .'. a
USER:PubliAUser pproval ARE THE RESPONSIBILITY OF K
.._. LC�i4r ACTT? t 9F -
Product Approval Menu > Product or Application Search > Application Us t > Application Detail.
FL # FL9777'-'R9
Application Type evision
Code Version 2014 THESE PLANS AivO ALL PROPOSED WORK
Application Status Approved ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
Comments ;ems Ce7AY EC ItECER0AM, hI'a OROETO
Archived 0I'>iiKY UVI H r% m � b,I�A.:. �: C-MES.
Product Manufacturer Owens-Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404=7829'
greg. keeler@owenscoming: com
Authorized Signature. Greg keeler
greg. keel er@owenscorning. corn
Technical Representative S 1.cR( l,�n,E� T0 1—M-FLESIGIN
Address/Phone/Email l?F''vMVI`v3 FOR CfjlI'LL4.NCE
Quality Assurance Representative }) T ✓ 49
Address/Phone/Email T''� :"LDS " PE_ ---P NIT EE 'UPT i�i>.`'; JOS
Category Roofing
Subcategory Under ayments
Compliance -Method Evaluation Report from a Florida Registered Architect or a Licensed F
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name• who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date, 12/31/2020
Validated By Locke Bowden
✓. Validation Checklist - Hard'copy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL9777 R9 COI OCR14092 6a FBC 2014 Evaluation Report Weathei
Non-HVHZ FINAL.odf
Year
ASTM D 1970
2009
ASTM D 226
2006
ASTM G 155
2005
TAS 1.03
1995
UL'1897
2004
Equivalence of Product Standards
0
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
04/12/2017
Date` Validated
04/12/2017
Date Pending FBC Approval
0.4/13/2017
Date.Approved
O6/13/2017
_Cnmmaw of Dendleefe
FL #
Model, Number or Name
Description
9777.1
Weatherlock G
Weatherproofing: Underlayment
Limits of Use
Installation Instructions
Approved'for,use'ln HVHZ:, No
Approved for use outside HVHZ: Yes
Impact'Resistant: N/A
FL9777 R9 1I OCR14002 6a FBC 2014 Evaluation Reoor
Weatherlock Non-HVHZ FINAL:odf
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Other: See evaluation report for limits of use.
'
Created by Independent Third Party: Yes
Evaluation ,Reports
{f FL9777 R9- AE 0C1114002.6a FBC 2014 Evaluation Ren
f Weatherlock Nob-HVHZ. FINAL
.Created by Independent Third Party: Yes
3777:2
WeatherLock G (High. Tear)
Weatherproofing Underlayment
!' Limits of. Use
Approved for use in HVHZ: No
Approved for use outside ,HVHZ:, Yes
Impact Resistant- N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL9777 R9 II OCR14002.6a FBC 2014 Evaluation Repoor
'Weatherlock Non-HVHZ FINAL.ndf
Verified, By: Zachary' R: Priest PE-74021
Created by Independent Third Party: Yes
.Evaluation Reports
FL9777 R9 AE OCR14002 6a FBC 2014. Evaluation Repc
r.Weatherlock Non-HVHZ EFINAL,odf
i
i
Created by Independent Third Party: Yes
--i-Weatherlock'
i 9777.3
MAT
Waterproofing, Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes;
,Approved for use outside-HVHZ: No.
FL9777 R9 II OCR-14002'6b FBC: 2014 Evaluation Reoor
Weatherlock HVHZ.pdf
Impact Resistant: N/A
'Verified By:- Zachary, R., Priest 74021
Design'Pressure: N/A
} Other: See evaluation report for limits of use.
'Created by Independent Third Party: Yes
Evaluation Reports
i
`
FL97'7 R9 AE' OCRI4002 6b FBC 2014 Evaluation geoc
Weatherlock
HVHZ pdf
Created by Independent'Third Parry: Yes:
9777.4
Weatheriock MAT,,
i Waterproofing Underlayment
Limits of Use
Approved for, use in HVHZ: No
Approved for use.outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
O'ther:.See evaluation report: for limits of use:
i Installation Instructions
F 77 R9 II 0 ' '4D02 6a FBC 2014 Evaluation Reoor
Weatherlock Non-HVHZ FINAL.odf
Verified By: Zachary R. Priest 74021
'Created by Independent Third Party: Yes
Evaluation Reports
'L97b 'R9-AE OCR14002 6a FBC 2014 Evaluation Repo
Weatheriock Non-HVHZ FINAL.odf
Created by Independent Third Party: Yes
-9777:5-
WeatherLock.Metal
Weatherproofing Underlayment
Limits of Use
Approved for use in HVHZ: No I
Approved for use outside. HVHZ: Yes
Impact Resistant: N/A
Design Pressure. N%A
Other: See evaluation report for limits of use.
;installation Instructions
FL9777- R9 II (t . R14002.6a FBC 2014 Evaluation Reoor
Wea herlock Non-HVHZ FINAL pdf
Verified By: Zachary R. Priest PE-74021
Created .by Independent Third Party: Yes
Evaluation Reports
FL907 R9 AE OCR14002 6a FBC 2014 Evaluation R 6
Ed
We'atherlack Non-HVHZ FINAL.pdf
Created by Independent Third Party:' Yes
9777.6
Weatherl-ock Metal
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL9777 R9 11 OCR14002 6b-FBC 2014 Evaluation Repor
Approved for use outside HVHZ: No
Wotherlock HVHZ.pdf
Impact Resistant: N/A
Verified By:. Zachary R: Priest PE-74021
Design.Pressure: N/A.
Other: See. evaluation report for limits of use.
Created by IndependentThird.Party: Yes
Evaluation Reports
FL9777R9 AE OCR14002 6b FBC 2014 Evaluation Regc
Weathercock HVHZ.pdf
-�
Created by IndependentThird.Party: Yes
19777.7
Weatherl-ock Specialty Tile & Metal
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777 R9 :11 OCR14002.6a FBC 2014 Evaluation Repor
Weathercock No FINAL�f
i Verified, B' Zachary R:"Priest 74021
i Created by Independent Third Party: Yes.
it Reports
Approved for use outside HVHZ: Yes
Impact Resistant:'N%A
Design Pressure: +0/-105
Other; See evaluation report for limits of use.
FL9777 R9 AE: OCR14002 6a FBC 2014 Evaluation Repo
Weathercock Non-HVH2 FINAL.pdf
_
Created by Independent'Third Party, Yes:
Contact Us.:: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850.487-1,824
The state of Florida is an AA/EEO employer. Copyright 2007-2013'State of'Florlda.::"privacy°Statement :: Accesslbifity Statement'.:; Refund Statement
,
Under Florida law,.email addresses are public records. if you:do not want your-e-mall address released:in response to a public -records request, do,notsend eie
mail to this entity. Instead, contact the office by phone or by traditional'malL If you hale any questions; please contact 850.487.1395:'*Pursuant to Sdalt
4 55.275(1),, Florida Statutes, effective October 1,"2012; licensees bcensed:under Ghapter.455; F.S. must provide the Department with an email address if the,
one.. The emalls provided -may be used for official communication .with the licensee. However'email addresses are public,retord. If you do not Wish to supply a p
address, please provide the Department.with.an.email. address which can be made aVailable to the public. To determi' -if you.are a licensee,under .Chapter45,
please click here
.
Product ApprovalAecepts:
'go ' R9 M
CreditSate Card
- ..
N j 1
CREEK
TECHNICAL SERVICES. LLC
EVALUATION REPORT
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL,33647
(813)480-3421
FLORIDA BUILDING -CODE 5T" EDITION
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued.A'prif 12, 2017
1 °Owens Coming Parkway
Toledo, OH 43657
(800)-438-7465
www.owenscorning.com
Manufacturing Location: Brentwood, NH
Houston, TX
Quality'Assurance: ULLLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1504.3.1,1507:2.4, 1507.2.8, '1507.2.9.2, 150,7.3 3; 1507...4 5, 1.507.4.5.2, 1507.5.3;
1:507.5.3.2,1507.7.3; 15,07.7.3:2'
Properties: Physical properties
REFERENCES
Enti
Report. No.
Standard'
Year
PRI Construction Materials Technologies (TST6049)
NEI-039,-02-01
ASTM D 1970
2009
PRI Construction;Materiais Technologies (TST6049);
NEI-042-02-01 REV2
ASTM D 1970
2009
PRI Construction Materials -Technologies, (TST6049)
NEI-045-02-01
TAS 103
1995
PRI Constructiop Materials Technologies (TST6049)
NEI-045=02=01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST6049)
NEI .53-02-01
TAS 103.
1995
PRI Construction Materials Technologies (TST6049)
NEI-053-02-01
ASTM G'155
.2005a
PRI Construction Materials Technologies
NEI-093-02-62
ASTM D 1970
2009
(TST6049).
PRI Construction Materials Technologies,(T8T6049) '
OCF-213 .2-Ot
ASTM D 1.623
2009
PRI Construction Materials Technologies'(TST6049).
OCF=237-02-0.1
UL 1897
2004
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 4798
2001
PRI Construction Materials:Technologies (T.ST6049). '
0CF=252-02-01;
ASTM D 1970
2009
PRI Construction Materials Technologies (TST5878)
0CF=253-02-02
ASTM D 1970
2009
PRI Constructidh. Materials>•Technologies (TST6049)
OCF=272=02.-01
TAS 103
1995
PRI Construction Materials Technologies (TST6049)
OCF-296=02=02
ICC=ESAC 188'
2012
ICC-ES.AC 48
2012
PRI Construction Materials Technologies (TST6049)
0CF-297-02-01.1
ASTM D 1970
2009
'Determined to be equivalent to ASTM'D 226-06; Type l and.11
s
OCR14002.6a FL9777-R9 Page 1 of 4
This evaluation report is provided for State of Florida product appYov'I under Rule 61 G20-3'. , The manufacturer shall notify CREEK
Technical Services, I LC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This, evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes_that are not
specifically addressed herein.
f
CREEK. OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLocW Self -Sealing Ice & Water'Barriers
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
WeatherLock@ G
WeatherLock® G is an. ASTM D 1970 self-adhesive underlayment constructed: from SBS
(Brentwood;. NH)
modified asphalt, a 'fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq. rolls with, nominal dimensions of 3=ft x 66,74
WeatherLock@ 'G is permitted to be used with mechanically -fastened asphalt shingles,
wood shakes or shingles;, and slate roofing as prescribed in the FBC. Exposure on the
roof :deck shall be limited to a maximum 30 days.
WeatherLock® Mat
WeatherLock@ Mat is art ASTM D 1970 self-adhesiveunderlayment constructed from
(Brentwood, NH or
SBS, modified asphalt with a :fiberglass mat reinforcement. The product is supplied in, 1-
Houston, 7X)
sq. rolls:with nominal dimensions -of 3-ft x 33:3=ftand 2 sq. rolls with nominal dimensions
of3.4 x, 66.7-ft.
WeatherLock@Mat is permitted: to be used with mechanically fastened asphalt shingles,
wood shakes or shingles,, and sate. roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to.:a maximum 30 days:
WeatherLock@, Metal
WeatherLock®' Metal is an ASTM D 1.970 self-adhesive underlayment constructed from
(Brentwood; NH)
SBS modified asphalt with a fiberglass mat reinforcement :and plastic film surface. The
product is supplied in'2.0 sq. rolls with nominal :dimensions of3=ft x:6ti.7=ff
WeatherLock@ Metal is permitted to -be:Used, 'with' mechanically fastened asphalt
shingles, metal roof ,panels or shingles,, wood shakes or shingles, and slate roofing as
prescribed' in the FBC_ Exposure on the roof deck shall be limited to a maximum 90
days.
Weatherl-ock8i
WeatherLock@ Specialty Tle & Metal is an-ASTM D 1970 self-adhesive underlayment
Specialty Tile &: Metaal
constructed from SBS• mod'+fied asphalt and,surfaced with; anon -woven .polyester fabric.
(Brentwood,,NH)
The product is supplied in 2.14 sq::rolls,with nominal dimensions of 3-ftx 71:3-ft.
ii I i
WeatherLock® Specialty Tile &' Metal is permitted to, be used with mechanically fastened'
asphalt shingles, clay. or _concrete the metal, roof panels or shingles, wood shaken or
shingles,; and slate roofing- as prescribed in ,the • FBC.. WeatherLock@ Specialty Tile &
Metal is permitted lobe used,wilh:adhpred clay.or concrete tile roofing using either 3MTM
2-Component Foam Roof Tile Adhesive AH'A66 (3M Company) or TILE BONDTM Roof
TileAdhesive.(The Dow Ch.gmtcal.,'Companyi Exposure on the roof. deck shall be limited'
to a: maximum 90 days:
The. maximum roof slope shall be-6:.12 when used. with clay or concrete the installations
Without battens. Tile shall be stored on battens for roof slopes ;greater than 6:12. Tiles'
shall :not be stacked greater 1'0 tiles per, stack, ,. ,
WeatherLock@ G (High
•WeatherLock@ G (High. Tear) is -a, self-gdhered,, underlayment used as an alternative-toTear)
ASTM D 226, Type I or Type II roofing felt :and ASTM D 1970self-adhering polymer
'(Houston; TX) ,
modified bitumen underlayment. The underlayment'is composed of SBS •modified,
asphalt with:s;fiberglass mat, interpal reinforcement.and is:surfaced with;granules;:The
product is' supplied with a' nominal thickness of 50 mils.,in 1;95sq rolls with nominal
dimensions of 3=ftx 65-ft.
WeatherLockO G (High Tear), is •piermitted,to be used` with mechanically fastened asphalt
shingles;. metal roofing„ slate: shingles, wood shingles and wood.. shakes as prescribed in
the,FBC, Exposure on the roof deck shall be limited to a' maximum 30 days.
OCR14002.6a
F077iR9 Page,2 of 4
This evaluation report Is provided for State of'Florida'product approval, under Rule•!61G20'3. The. manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quaiity assurange changes throughout ihe:duration for.which this'report is valid.
This: evaluation report does not express nor imply warrantyr installation, recommended use, or other product attributes that are not
specifically addressed herein.
E
t
CREED
TECHNICAL SFERVICCS, L.L.0
PRODUCT APPLICATION
01
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing, Ice & Water Bartlers
Min. Roof Slope;
2:12 or in accordance in with the FBC
Application:
All underlayments shall be installed in accordance with. the FBC.
Deck substrates shall be clean, dry, and free from any .irregularities and debris. All
fasteners in the deck shall be checked for protrusion and correctedprior• to undedayment
application. Prior to beginning installation, the un'derlayment shall be, unrolled' and
allowed to relax -fora minimum of 3-5 minutes:
The underlayment shall be installed with the release. backer removed' and pressed firmly
into place to ensure, complete. contact with the deck. The undedayment shall be installed
with the roll length parallel to the eave, starting at the eaves and, with minimum 3" side
laps and minimum 6" end laps staggered 'min. 6-ff.from preceding course. Additionally, if
applying, Weathercock® Specialty Tile &. Metal, end laps shall be primed with ASTM D
41 primer or sealed with asphalt roof cement. a minimum .of 34 inches across'the width
of the lap,.
It -is permissible to back nail the undedayment 12-inches on -center as needed. (nails. shall
be installed perpendicular to deck: with the nail heads flush to the, top surface of the
unded yment): Additionally, Weathercock® Specialty Tile &.Metal shall be back nailed
When installed'on roof, slopes greater than 3:.12.
Min. Application
40°F; Contact the manufacturer when installing at temperatures below the. minimum
Temperature:
application temperature.
WIND RESISTANCE
The Maximum 'Design Pressure`' shown below were. calculated using a 2*1 'margin of safety. per FBC Section,1504.0
Underlavment System No.1 •— WeatherLock-Specialty Tile BMetal Orily
Roof Deck: M.in. 15/32-inch CDX.plywood, 6ttached•to woodsupports spaced a maximum 24" o.c.
Undedayment: Weatheitocli® Specialty Tile & 'Metal: shall be applied in accordance with
manufacturers installation instructionsao the fastened deck and backnailed along the
selvage With -minimum 12ga., 1-1144ch ga►vanized . ring shank roofing nails through,
optionally primed, 32ga. x 1,;5/6-inch 0 'tin caps spaced 12" ,mc., The applied:
underlayment shall, be rolled with a minimum i516'"steep roller immediately following
application. ;
Maximum Design -105 psf
Pressure:
OCR14002.6a FL9777-139 Page 3 of 4
This evaluation report is provided for$tate of Florida product approval, under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or•quality assurance changes:throughout the duration for which this report is valid.
This evaluation report does not express norimply warranty, installation, recommended use, or other product attributes that are not
spec(ficalIVaddressed herein:
OWENS CORNING ROOFING AND ASPHALT LLC
CREEK WeatherLack-1 Self -Sealing Ice, B Water Barriers
TECHNICAL SERVICES, LLC
GENERAL LIMITATIONS
1) This•evaluation report is not use in the HVHZ.
2) Fire Classification is:mot within the scope of this evaluation.
3) Installation of the. evaluated product shall comply with this (eport, the FBC, and the: manufacturer's published
application .`instructlons. Where discrepancies exist: between these sources, the more restrictive. and FBC
compliant, installation detail shall prevail..
4) The roof deck shall be, consiructed.of.closelytitted. plywood sheathing..or new or existing construction.
5) The space under ther deck area shall be properly ventilated in accordance with the FBC requirements..
6) All side,lap seams shall be installed to shed water from the,deck.
7) The underlayment maybe used'as describedin: other current-FBC product approval documents,
8) Design, wind .load pressures shall be determined, for components and cladding in accordance with FBC
1609.
9)' The roof deck shall be designed by others in .accordance with FBC' requirements to resist the design wind.
load pressures for components sand cladding.
10) Maximum Design 'Pressures fora given. underlayment shall meet or exceed the design wind loads
determined' for the roof assembly.
11) All products,listed' in this report shall be. manufactured under -a quality assurance program in compliance with.
Rule 61 G20-3.
COMPLIANCE.STATE] ENT
�h y Zachary compliance with the Florida Building
The products: evaluated herein b Zacha R. Priest, P:E. have demonstrated
Code-5 Edition (21 14) as evidenced in the referenced documents submitted: by the named manufacturer.
�R��p���,4
{ s�G,•1,�G B NSA ��5 err
20 17.04.12
,,,,�, .
* , No 74`021 . *
4
--15.:15:46
STATE OF •<c1
—04100''
Zachary. R. Priest, P.E.:
21.
Organization No ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical'Seryices,'LLC does not have, nor will it;acquire, a financial interest in any company. manufacturing, ordistributinq
products under.this evaluation. ,
CREEKT.echnicai Services, LLC is not owned, operated; or controlled by,anycompany,manufacturing.ordistributing products under
this evaluation.
Zachary R. Priest,; P.E. does not'h'ave, nor will acquire; a financial interest In any company manufacturing, or distributing products
unden'this evaluation.
Zachary R, Priest, P.E. does nothave;.. nor will acquire, a financial interest.in any other,entity involved in the approval process of the,
product.
This evaluation report is provided for State -of Florida
Technical'Services, LLC of any product'changesor.q
This evaluation report does not express nor imply m
specifically addressed herein.
END,w REPORT
4of4
changes throughout the duration: for which this report:is,Valid.
n; recommended use; or otherproduct attributes that are not