Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL MODIFIED BITUMEN ROOF SYSTEMBC1S Home •f Log In [ User Registration b 1Product Approval USER: Public User d ��4 '. r. Hut Topics I Submit Surcharge : Slats & Facts i Publications FBC Staff ( BCIS Site Map 1 Links ' Search product AAorQ-1 monu > Prnontt or �nohcation Search > A"yc tim Llst > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL1654-R19 Revision 2014 Approved POLYGLASS USA 150 Lyon Drive Fernley, NV 89408 (570)384-1230 Ext242 jakins@polyglass.com James Akins jakins@polyglass.com RECEIVED OCT 0 4 2017 PERMITTING St. Lucie County, FL a5o5 Steve Wadding 150 Lyon Drive Fernley, 3- 98408 (602)363-7134 stevew@polyglass.com PY James Akins 555 Oakridge Road Humboldt Industrial Pkwy Hazleton, PA 18201 (800)894-4563 jak'ins@polyglass.com Roofing Modified Bitumen Roof System Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/06/2018 Validated By John W. Knezevich, PE 'Z= Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) FL1654 R19- COI 22 16 01 CQI Nieminen.pdf Standard Year ASTM D6162 2000 ASTM D6163 2000 ASTM D6164 2005 ASTM D6222 2008 ASTM D6509 2009 FM 4470 1992 FM 4474 2004 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/1812016 Date Validated 04/19/2016 Date Pending FBC Approval 04/20/2016 Date Approved 06/08/2016 Summary of products FL # Model, Number or Name Description 1654.1 Polyglass SBS and APP SBS and APP modified bitumen roof systems Modified Bitumen Roof Systems Limits of Use Installation Instructions. Approved for use in HVHZ: No FL1654 R19 11 2016 04 FINAL At ER POLYGLASS MODBIT FL1654- I R19.6df Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this Evaluation Reports application relates to one particular assembly FL1654 R19 AE 2016 04 FINAL ER POLYGLASS MODBIT FL1654- R 19.Ddf over concrete deck. Refer to the ER Appendix for other systems and deck types. 2.) Refer to ER, Created by Independent Third Party: Yes Section 5 for other Limits of Use. Back Ne:t 1 Contact Us :: 7601 Blair Stage Road, Tallahassee FL 32399 Phone: 850-407-1624 The State of Florida is an AAIEEO employer. Coovrioht 2007-2013State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida taw, email addresses are public records. If you do not want your a -mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 050.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 20I2, licensees licensed under Chapter 455, F.S. must provide the Department with an email address It they have one. The emaRs provided may be used for official communication with the licensee. However email addresses are public record, 11 you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To determine if you are a Ikensee under Chapter 455, F.S., please click here . Pim�drrcc Approval Accepts: Credit Card Safe EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 TRINITY, j� ® '�/ ` C 353 Christian Street = ; ! RINI 1 1 C�® Oxford, Cr 06478 ' PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Polyglass USA, Inc. Evaluation Report P9290.02.08-1117 150 Lyon Drive FL1654-1119 Fernley, NV 89408 Date of Issuance: 02/11/2008 Revision 17: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED CompuANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5, plus a 45-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DC4 ANE1983 s p Cj�_.b The faaimile seal appearing was authorized by Robert Nieminen, P.E.on 04/18/2016 This does notseneasaneleUron'ragysreddvcumert.Signed, ;innz�sssss sealed.Fiardcopies have been transmitted to the Product Approral Administrator and to the named dient CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product 5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. l TRINITY ; ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: Polyglass SBS and APP Modified Bitumen Roof Systems, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2004 1504.7 Impact FM 4470 1992 1507.11.2 PhysicalProperties ASTM D6162 2000 1507.11.2 Physical Properties ASTM D6163 2000 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2008 1507.11.2 Physical Properties ASTM D6509 2009 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Physical Properties P10490.10.08-2 10/30/2008 ERD (TST6049) FM 4470/4474 P13760.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P13770.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P30540.11.09-R1 11/30/2009 ERD (TST6049) 'FM 4470/4474 P30550.12.09 12/02/2009 ERD (TST6049) Physical Properties P33960.12.10 12/30/2010 ERD (TST6049) FM 4470/4474 P33970.03.11 03/15/2011 ERD (TST6049) Physical Properties P37590.03.13-3A 03/06/2013 ERD (TST6049) FM 4470/4474 P39680.03.13 03/04/2013 ERD (TST6049) Physical Properties P37590.03.13-1-R1 06/26/2013 ERD (TST6049) Physical Properties P37S90.03.13-2-R1 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-2 07/01/2013 ERD (TST6049) Physical Properties P37590.03.13-5-R1 07/01/2013 ERD (TST6049) Physical Properties P3759OX.13-1 07/02/2013 ERD (TST6049) FM 4470/4474 P41630.08.13 08/06/2013 ERD (TST6049) Physical Properties 1)45940.09.13 09/04/2013 ERD (TST6049) Physical Properties P44370.10.13 10/04/2013 ERD (TST6049) FM 4470/4474 SC6160.iL14 11/10/2014 ERD (TST6049) Physical Properties PLYG-P45440SC.03.15-1 03/31/2015 ERD (TST6049) Physical Properties SC5170.05.15 05/08/2015 ERD (TST6049) FM 4474 SC8085.05-15 05/19/2015 ERD (TST6049) FM 4470/4474 SC8905.15 01/18/2016 ERD (TST6049) Physical Properties SC5170.12.15 12/29/2015 ERD (TST6049) FM 4470/4474 SC9455.15 04/01/2016 FM Approvals (TST1867) FM 4470 2w7A7.AM 08/04/1994 FM Approvals (TS71­1867) FM 4470 OD3A3.AM 04/04/1997 FM Approvals (TST1867) FM 4470 2DOAO.AM 12/23/1998 FM Approvals (TST1867) FM 4470 2D5A9.AM 06/22/1999 FM Approvals (TST1867) FM 4470 3006646 01/04/2000 FM Approvals(TST1867) FM 4470 3001334 01/25/2000 FM Approvals (TST1867) FM 4470 3001334 02/15/2000 FM Approvals (TST1867) FM 4470 3000857 01/12/2000 FM Approvals (TST1867) FM 4470 3004091 01/12/2000 Exterior Research and Design, LLG Evaluation Report P9290.02.08-R37 Certificate of Ruthorkation f>9503 FL1654-R34 Revision 17: 04/18/2016 Page 2 of TRINITY ERD Entity Examination Reference Date FM Approvals (TST1867) FM 4470 3006115 05/02/2001 FM Approvals (TST1867) FM 4470 3012321 07/29/2002 FM Approvals (TST1867) FM 4470 3014692 08/05/2003 FM Approvals (TST1867) FM 4470 3014751 08/27/2003 FM Approvals (TST1867) FM 4470 3007170 01/13/2004 FM Approvals (TST1867) FM 4470 3019317 06/30/2004 FM Approvals (TST1867) FM 4470 3020703 07/30/2004 FM Approvals (TST1867) FM 4470/4474 3018332 01/31/2006 FM Approvals (TST1867) FM 4470/4474 3023368 03/20/2006 FM Approvals (TST1867) FM 4470/4474 3024594 05/23/2006 FM Approvals (TST1867) FM 4470/4474 3023458 07/18/2006 FM Approvals (TST1867) FM 4470/4474 3030668 09/12/2007 FM Approvals (TST1867) FM 4470/4474 3032172 06/12/2009 FM Approvals (TST1867) FM 4470/4474 3049631 04/21/2014 PRI (TSTS878) Physical Properties PUSA-062-02-01 12/04/2007 PRI (TST5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST5878) Physical Properties PUSA-064-02-02 02/27/2008 PRI (TST5878). Physical Properties PUSA-062-02-02 12/04/2009 Miami -Dade (CER1592) HVHZ Compliance Various NOAs Various Miami -Dade (CER1592) Proposal for Review 10-0823 10/12/2010 UL LLC (QUA9625) Quality Control Service Confirmation, R14571 Exp. 10/06/2018 4. PRODUCT DESCRIPTION: This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc_ published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass membranes make up the subject systems. TABLE 1: ROLL GOODS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS Type Product Specification Reference Grade Type Base Sheets Polyglass G2 Base ASTM D4601 N/A 1[ Polyflex SA Base ASTM D4601 N/A II Polyglass APP Base ASTM D6509 N/A N/A SBS Membranes Polyglass HT Base 650 ASTM D6162 S II[ Elastobase ASTM D6163 S I Elastoflex V ASTM D6163 S I Elastoflex SA V Base ASTM D6163, Table 2 S I Elastoflex SA V FR Base ASTM D6163, Table 2 S 1 Elastoflex SA V Plus ASTM D6163 S I Elastoflex SA V Plus FR ASTM D6163 S I Elastobase Poly ASTM D6164 S I Elastoflex S6 ASTM D6164 S I Elastoflex VG ASTM D6163 G 1 Elastoflex VG FR ASTM D6163 G l Elastoflex S6 G ASTM D6164 G I Elastoflex S6 G FR ASTM D6164 G 1 Polyfresko G SBS (sand or poly -film backed) ASTM D6164 G I Polyfresko G SBS FR (sand or poly -film backed) ASTM D6164 G I Elastoshield TS G ASTM D6164 G I Elastoshield TS G FR ASTM D6164 G I Elastoflex SA P ASTM D6164 G I Elastoflex SA P FR ASTM D6164 G I Polyreflect ASTM D6164 S I Exterior Research and Design, LLC. Evaluation Report P9290.02A8-R17 CerWate of Authorization N9503 FL1654-R19 Revision 17. 04/18/2016 Page 3 of 5 .J TRINITY 1 �R. TABm.1: ROLL -GOODS FOR POLYGLAss MODIFIED BffuMEN ROOF SYSTEMS Type Product Specification Reference Grade Type APP Membranes Polyflex ASTM D6222 S I Polyflex G ASTM D6222 G I Polyflex G FR ASTM D6222 G 1 Polyfresko G ASTM D6222 G I Polyfresko G FR ASTM D6222 G I Polybond ASTM D6222 S l Polybond G ASTM D6222 G I Polyflex SA P ASTM D6222 G I Polyflex SA P FR ASTM D6222 G I Polyfresko G SA ASTM D6222 G I Polykool ASTM D6222 5 I 5. LIMITATIONS: 5.1 This is a building code evaluation. NeitherTrinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in HVHZ. 5.3 Refer to a current Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1510. 5.7 For mechanically attached insulation or membrane .or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 5.8 For fully -adhered insulation, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. Exterior Research and Design, LLC- Evaluation Report P9290.02-08-1117 Cw0ficam of Authorizotion#9503 FL165"19 Revision 17: 04119/M16 Page 4 of 5 M1Y TRINITY ERD 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52 or TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or RAS 111, except the basic wind speed shall be determined from FBC Figure 1609. 5.13 All products in the roof assembly shall have quality assurance audit in accordance with the FBC and F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Polyglass Modified Bitumen roof systems shall be installed in accordance with Polyglass USA, Inc. published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 6.3 Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. ➢ PG200 Non-Fibered Roof Coating; ➢ PG300 Fibered Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating; PG650 Fibered Aluminum Roof Coating; ➢ PG700 High Quality Elastomeric Roof Coating or KM Acryl 25; • PG700QS (Quick -Set) High Quality Elastomeric Roof Coating or KM Acryl 25-QS (over granule -surfaced APP or SBS only); ➢ PG800 Asphalt Emulsion Roof Coating; ➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating; ➢ Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15; ➢ Polybrite 70QS (Quick -Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS (over granule - surfaced APP or SBS only); ➢ Polybrite 90 High Solids Silicone Roof Coating; ➢ Polybrite 95 Silicone Roof Coating. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements 9. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625; (314) 578-3406, k.chancellor@us.ul.com - THE45-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, LLC_ Evaluation Report P9290.02211-R17 [erWcote of Authorization #9503 FL165" 9 Revision 17. 04/18/2016 Page 5 of S TRINITY ERD RPPENmx LATTAO MEW REO.UIREMENLS FOR WMD Unn RMSTANCE Table Deck Application Type Description Page 1A Wood New-Reroof (Tear•Off) A-1 Bonded)nsulation, Bonded Roof Cover 5 18-1 Wood Newor Renwf(TeanOff) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded. Roof Cover 5-9 18-2 Wood New, Reroof (Tear -OM or Recover A-2 Mech. Attached Anchor Sheet, Bonded insulation, Bonded Roof Cover 10-11 IC Wood New, Remof (Tear -Oft) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 12 10 Wood New, Rated (Tear -Off) or Recover C Mach, Attached insulation, Bonded Roof Cover 13.14 1E Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached insulation, Mech. Attached Base Sheet, Bonded Roof Cover 15-16 1F4 Wood NeworRemof (Tear-M u..., Re.....Fff.—fn—R..r E L Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover Merh. Attarhed,BasesheetEscrows&oWeil. :Bonded .Roof Cover-- 17-19 20-22 2B Steelor Cone. New, Remof(Tear-OM or Recover C Mech. Attached Insulation, Bonded Roof Cover 24-25 2C Steel or Conc. New,Remof (Tear -OR) or Recmrer D Prelim. Attached Insulation, Mech. Attached Base Sheet. Bonded Roof Cover 26-27 3A Concrete New or Reroef (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 28-32 38 Concrete Newor Reroof (Tear -Off) F Non -insulated, Bonded Roof Cover 32 4A LWIC Neworfteroof(rear-OM A-1 Bonded Insulation, Bonded Roof Cover 33-34 4B LWIC New orRemof(Tear-= A-2 Mech. Attached AndrorSheet Bonded Insulation, Bonded Roof Cover 34 4C LwiC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 35-37 SA CWF Mew or Reroof (T—Off) A-1 Bonded Insulation, Bonded Roof Cover 38 56 CWF New, Reroof (Tear -OM or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 39 SC CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top insulation, Bonded Roof Cover 40 SD CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 40 SE CWF New, Reroof (Tear -Off) or Recover E Non -insulated, Mech. Attached Base Street, Bonded Roof Cover 40 GA Gypsum Reroof (Tear -Of) A-1 Bonded Insulatlon, Bonded Roof Giver 41.42 68 Gypsum Reaoof (Tear -Off) or Recover A-2 Mech. Attached AnchorSheet, Bonded Insulation, Bonded Roof Cover 42 6C Gypsum Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 42 6D Gypsum Remof(Te—Off)or Recover E Non-Insulated,Merh. Attached Base Sheet, Bonded Roof Cover 42 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 43-45 7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 45 The follmi ne notes apply to the systems outlined hernia: L The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through propercodified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of suffclent length fortho following deck engagement: Ywood.- Minimum 0.75-inch pemtration. i-Steel: Minimum O.75-inch penetration and engage the sup flute of the steel deck. ➢Concrete: Minimum 14nchembedmentfnto pilothole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyranurate, polystyrene, wood fiberboard, perlite, gypsum-basod roof hoard or mEneral-wool mof board that meets the CIA requirements of FAG Rule 61GM-3 and is documented as meeting FBC 35051 and, for foam plastic, FBC Chapter 26, when installed with the roof ewer. Exterior Research and Design, LLG d%b/a Tdnity)FRD Evaluation Report P9M.GZ084U7 for F1.16544119 Certificate of Authoriration#9503 Revision 17:04/18/2015 Prepared by: Robert Nfeminen, PE•59166 Appendix 1, Page 1 of 45 ��' TRINITY ! ERD 4. Minimum 2DO psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are Installed through the L1MC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings- Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHl. Load resistance ofthe roof deck shag be documented through proper codified and/or FBC Approval documentation. S. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width Is at the time of application; the ribbow1beads shall expand as noted in the manufacturers published instructions. Y Hotasphalt(fIA): Full coverage at 25-30 Ibs/square. > Dow Insta-Stik Rkwfm& Adhesive (DdS): Continuous 0.75 to 1-Inch wide ribbons, 124nch ozc > Millennium One Step Foamable AdhesW(M-OSFA): Continuous 0.25 to 05-int}r wide ribbans„ 124mh oz. > OMG OWond 500 (065Do): Continuous 03S to 1-Inch wide ribbons, 12-inch c.c. (PamCart or SpotShot). Note. OlyBond Green may be used where Olygond 50O is referenced Y OlyBond Classic (OB Classic): Full coverage at 1 gallsquare. > ICP Adhesive & Sealants CR-20: Continuous 25-354nch wide ribbons, 12-Inch oz. Y Note: When multiple (oyers(s) 4fnsulo0on and/or coverboard are hastofled in ribbon -applied adhesive, boerd%aintsshall bestaggered. > Note: The maximum edge distancefrom the adhesive ribbon to the edge o/the insulation board shag be not less than one-hafff the spedfeed ribbons spacing. 6. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. in no case shag these values he used to'increase' the MDP listings In the tables; rather if MDP listing below meets or exceeds that fisted for a particular system In the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: Y Millennium One Step Foamable Adhesive(M-OSFA): MDP -2575 psi (Min. 05-inch thick) Y OMG O)yBpnd 500(OB500):. MDP -45.0 psi (Min.05inch thick Muhi-Max FA-3) Y OMG OhGond 500 (011500): MDP -I875 psf (Min.OS-inch thick ISO 95t GL) Y OMG OWnd 500 (OBSW): MDP -315.0 psf (Min 0.5-inch thick ENRGY 3) Y OMG OlyBand 500 (OBSOO): MDP -4975 psf (Min. D-5-Inch thick ACFoam II) >ICP Adhesives & Sealants CR-20: MDP -1175 psi (Min. LOtinch thick) 7. Bonded pofyisocyanurateinsulation boards shall bemaximum 4x4ft. a. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shag meet or exceed the Zone 1 design pressure determined In accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM IPDS 1-29. Assemblies marked with an asters** carrythe limitations set forth In Section 2.2.15.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 9. Forfullyboaded assemblies, the maximum design pressureforthe selected assembly shall meet or exceed criticaldesign pressure determined In accordance with FBCChapber 16,and no radonalanalysis is permitted. 10. For mechanically attached components over existing decks, fastenners shag he tested in the existing deck for withdrawal resistance. A qualified design professional shag review the data for comparison to the minimum requirementsfor the system. Testirg and analysis shall be in aceordancevn-thTAS 365 or ANSI/SPRI FX-1. 1L For existing substrates In a bonded recover installation, the existing roof system shall beexamined for compatibility and bond performance with the selected adhesive, and the existing roofsystem shag be capable of resisting project design pressures on its own merit to the satisfaction of the AW, as documented through field uplift testing in accordance with ASTM E907, FM LPOS MZ ANSI/SPRI IA-1 orTA5124. 12. For Recover Applications using System Type D, the insulation is optional;however, the existing roofsystem shall be suitable for a recover application. 13. LWIC shall be cast In accordance with FBC Section2927 to the satisfaction of the Authority Having Jurisdiction. Forsysuems where spatofic,LWIC Is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. For systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi, in all case; the minimum top -coat thickness is 2-inches. For LWIC ever structural concrete, reference is made to FBC Section 1917A.1, Point L Exterior Research and Design, LIC. d/b/a Trbdty(ERD Evaluation Report P9290A2.D84U7 for F 16544t19 Certificate of Authodration#.9503 Revision 17:04/18/2016 Prepaneiby: Robert Nieminen, PE-59166 Append-ou1,Page2o14S TRINITY! ERD TABLE IF2: WOOD DECKS— NEWCONSTRUCIFION, REROOF(TWt-OFF)ORREMVER SYSTEMTYPEE: NON -INSULATED, MECHANICALLY ATTACHEDBASESHEET (SCREws&PLATEs),BONDED ROOF COVER Dedc(See Base Sheet RooECover(SceTsMe1) MOP System No. Note2.) Type Fasten Attach Base Ply cap (P� Mire 19/32- Efast base, Etastobase P (poly -film Deldast Hex with Deldast 414 or Trufaa 3" Metal 12-inch ox- In 44nch lap and 12=mch o.G in two ��� SBS-50. APP-SA. 525• W-334 Inch plywood top) Insulation Plate withTrufast HD (2), equally spared, staggered center rows 50S-TA, APP TA Min. 19/32- Elasiohase, Elastnhase P(poly-fdm DeKast Hex with Deklast014 orTrufax 3P Metal 12-Inch—in4-Inch lap and 124mh or -in two Pe1�sA� APPTA -52.5• W-135 Inch ptywood top) Insulation Plate witIrTtufast HD (2),equally spaced, staggered center r"s Mht.19/32- Eta base, Elastobase P (poly -film OMG Flat Bottom Plates (square) with Raofgrfp 12-inch oc m 44nch lap and 12-inch o.c. in two 585-SA. SBS-SA, APPSl1, SBS-TA, APP TA -60.0' W-136 inch plywood *00) 012 (2). equally spaced, staggered center ran Min. 19/32- Elaslobase, Elastobase P(poly-(ilm OMG FIatJ 2lates(squa 12-inch o. in 4-Inch lap and 12-inch o.c. to two ase APPTA -W.0• W-137 Inch pywood top) R32 -_. (2J, equa TABLEIG: WOOD DECKS —NEW CONSTRUCTION OR REROOF(TWu OFF) SYSTEM TYPE FNON-INSULATED, BONDED ROOF COVER " System D (See _ Roof Cmmr(SeeToble 1) MOP ( t>� Joint Treatment Base Ply Ply cap No. ctel) Primer (Optional)SBS-SA, SBS- SBS-SA,APP-SA•SB5- -510.0 W_138 M .35/32- (Optional) PG100 None SBS-SA T0. APPTA TA.APP-TA i hpywoad W-139 in. 15/32- (Oplanal)PG100 None PolyFlexSA Base (Optional)APP-TA APPTA -90.0 imJh plywmd Min. 15/32- Plywoodloints are covered with 4-Inch wide strips of Elastollm SA V Plus, urged into Elastoflex SA V (OpttoP-TA-514585- - -97.5 W-144/ r inch plywood Optional) PG300 place to to continuous band. FR Baseeer Elasmflex SA V FR Base TA, APP TA TA, APPAPP-TA T0. APP TA w188Mm. 5(opUomq - . ffia APP TA �p�. / 35/32- inch pyvmod c Evaluation Report P9290.0208-837 for FU.654-R19 Exterior Research and Des180. I.I.C.m't C. d/b/a Try)ERD Reg(son 17:04/1912016 Certificate ofAuthm®tion R9SW Appendix 1, Page 22 of 45. Prepared bT. Robert Nieminelq PE-59166