HomeMy WebLinkAboutPRODUCT APPROVAL STRUCTURAL WALLSS
Florida Building Code Online Page 1 of 2
sln,bs8t Pre �. °-� o _
BCIS Home I Log In User Registration Hot Topics Submit Surcharge Stats & Facts I Publications FBC Staff BCIS Site Map Links Search
Florida
trti �, xPD Product Approval
uSER: Public User
8n F�m
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL # FL20727
•'Y
Application Type New
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer Carolina Carports,Inc.
Address/Phone/Email 187 Cardinal Ridge Trail
Dobson, NC 27017
(336)367-6400
FLvalidation@yahoo.com
Authorized Signature robert cope
jason.c@carolinacarports.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Structural Components
Subcategory Structural Wall
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Terrence E. Wolfe
the Evaluation Report
Florida License PE-44923
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/05/2027
Validated By Locke Bowden
R Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
FL20727 RO COI Letter of Certification.pdf
Standard
ASTM E 1592
Method 1 Option D
Year
20b5
F� � I
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvFGl WOugH... 9/19/2017
G
Florida Building Code Online
Page 2 of 2
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
06/16/2016
07/21/2016
07/28/2016
10/13/2016
FL #
Model, Number or Name
126
Description
20727.1
Ga. AG Wall Panel
26 Ga. AG Wall Panel over Open Framing
Limits of Use
Installation Instructions
Approved for use in.HVHZ: No
FL20727 RO II 26 Ga. AG Wall Panel Detail.odf
Approved for use outside HVHZ: Yes
Verified By: Terrence E. Wolfe, P.E. 44923
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +46.9 psf/-59.9psf
Evaluation Reports
Other: See Evaluation Report for additional design
FL20727 RO AE 26 Ga. AG Wall Panel.pdf
pressures. Install per manufacturer's details. Not for use. in .
Created by Independent Third Party: Yes
HVHZ Zones.
.
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee Fl. 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. CoovHaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
MM® _Q M
Uedit Card
Safe
secllrit�r�ru�t>Ics`
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvFGI WOugH... 9/19/2017
PANEL FASTENER 2-1-2=1 :PATTERN
OR MIN. 14. GA. (GRADE 50) STEEL TUBE FRAMING
(SEE TABLE A FOR SPACING)'
#12-14 x 3/4" HWH SD#3 .W/ 5/6" (16mm) DIAMETER SEALING WASHER
�,.° NCB E 'w�I•,y
Soho of Flolfd� •�' 4 ' •' �G E N w.
No.4'4923
STATE OF
0
•. •.< O R'1 `••G��0.
J UN 16 2'016