Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
CERTIFIED SOLAR COLLECTOR
d + - CERTIFIED SOLAR COLLECTOR SUPPLIER: BRAND: AltemateEnergy ~ ' _ ® Alternate Energy Technologies 1345 Energy Cove Court MODEL: AE 40 ' ` Green Cove Springs, FL 32043 USA COLLECTOR TYPE: Glazed Flat Plate www.aetsolar.com CERTIFICATION N: 10001820 In Accordance with: Original Certification: April 16, 2013 -- - O SRCC Standard 100-2010-08 Expiration Date: December 03, 2024 i The solar collector listed below has been evaluated by the Solar Rating & Certification Corporation'"' (SRCC'v), an ISOIIEC 17065 accredited and EPA `-!t•'• recognized Certification Body, in accordance with SRCC OG-100, Operating Guidelines and Minimum Standards for Certifying Solar Collectors, and has been C certified by the SRCC. This award of certification is subject to all terms and conditions of the Program Agreement and the documents incorporated therein by }<' <% reference. This document must be reproduced in its entirety. v COLLECTOR THERMAL PERFORMANCE RATING Idlowatt-hours (thermal) Per Panel Per Day Thousands of Btu Per Panel Per Day Climate-> High Radiation (6.3 kWhlm'.day) Medium Radiation (4.7 kWtUm'.day) Low Radiation (3.1 kWhlm'.dey) Climate -> High Radiation (2000 Btulft'.day) Medium Radiation (1500 Btuift'.day) Law Radiation It000 Btulft'.day) Category (Ti-Ta) Category (Ti-Ta) A (-5 'C) 17.5 13.2 9.0 A (-9 'F) 59.6 45.1 30.8 B (5 -C) 15.3 11.1 6.9 B (9 °F) 52.4 37.9 23.6 C (20 °C) 12.2 8.1 1 4.0 C (36 'F) 41.7 1 27.5 1 13.6 D (50'C) 6.3 2.7 011 D (90 T) 21.6 9.1 0.2 E (80'C) 1.3 0.0 0.0 E (144'F) 4.6 0.0 0.0 A- Pool Heating (Warm Climate) B- Pool Heating (Cool Climate) C- Water Healing (Warm Climate) D- Space & Water Heating (Cool Climate) E- Commercial Hot Water & Cooling COLLECTOR SPECIFICATIONS Gross Area: 3.690 m' 39,72 ft' Dry Weight 69 kg 153 lb Net Aperture Area: 3.475 m' 37.40 ft' Fluid Capacity. 4.6 liter 1.2 gal Absorber Area: 3.385 m' 36.44 ft' Test Pressure: 1103 kPa 100 psi TECHNICAL INFORMATION Tested in accordance with: ISO 9EI06:1994 ISO Efficiency Equation [NOTE: Based on gross area and (P)=Ti-Ta) SI UNITS: r)= 0.755. 5.22470(PIG) - 0.01950(P'IG) Y Intercept: 0.760 Slope: -6.215 Wlm'.'C IP UNITS: n= 0.755- 0.92081(PIG) - 0,00191(P'IG) Y Intercept: 0.760 Slope: -1.095 Btulhr.ft'.'F Incident Angle Modifier Test Fluid: Water 0 10 20 30 40 50 60 70 Test Mass Flow Rate: I 0.0194 kgl(s m') I 14.29 Ibl(hr ft') Kra 1.00 1 1.00 0.99 0.97 0.93 0.79 1 Impact Safety Rating: 11 REMARKS: �Gis•t �Cc�tj!/N.1• Technical Director f. y Ar Z•. hhS St. Lucie Gotlnt,r; FL Print Date: August, 2015 Page 1 of 3 Please verify certification is active on the SRCC website. © Solar Rating & Certification CorporationT" ♦ 400 High Point Drive, Suite 400 ♦ Cocoa, Florida 32926 4 (321) 213-6037 ♦ Fax OG-100 CERTIFIED `{�� ) 821-0910 ;" -"' CERTIFIED. SOLAR COLLECTOR SUPPLIER: BRAND: AlternateEnergy Alternate Energy Technologies MODEL: AE40 1345 Energy Cove Court Green Cove Springs, FL 32043 USA COLLECTOR TYPE: Glazed Flat Plate {„ ; �; ,.,•;. i � w ww,aetsolar.com CERTIFICATION #: 10001820 In Accordance with: Original Certification: April 16, 2013 +:f SRCC Standard 100-2010-08 Expiration Date: December 03, 2024 The solar collector listed below has been evaluated by the Solar Rating & Certification CorporationT" (SRCCT"), an ISOIIEC 17065 accredited and EPA recognized Certification Body, in accordance with SRCC OG-100, Operating Guidelines and Minimum Standards for Certifying Solar y Collectors, and has been certified by the SRCC. This award of certification is subject to all terms and conditions of the Program Agreement and the documents incorporated therein by reference. This document must be reproduced in its entirety. •y T ADDITIONAL INFORMATION (click here to return to the rating page) Test Lab: Atlas Weathering Services Group I Test Date: December 03, 2012 Test Report Number: R2 AT28423 Test Location: outdoors SOLAR COLLECTOR CONSTRUCTION DETAILS Gross Length: 1 3.078 m I Gross Width: 1.199 m Gross Depth: 81.080 mm COLLECTOR MATERIALS Outer Cover. Glass sheet Enclosure back: Aluminum Back Insulation: Foam, None Inner Cover. None Enclosure side: Aluminum Side Insulation: Foam, None Absorber Description: Tubes connected to Fins Flow Pattern: Parallel/Harp Riser Tube: Copper Fin: Copper Absorber Coating: Selective Tube to fin connection Laser Weld GLAZING Outer Cover Inner Cover Material: Glass sheet None Surface Characteristics: Textured Thickness: 3.2 mm NIA Trensmissivity: High (equal to or greater than 90%) Length: 3.027 m Width: 1.148 m Tube Glazing to Header Endosure Seal: EPDM gasket ABSORBER: Absorber Coating: Selective T Header Material: Copper Header OD: 28.6 mm Header Wall: 0.9 mm 4,5 Riser Tube Material: Copper Rlser Tube OD: 10.0 mm Riser Tube Wall 0.6 mm Thickness: Fin Material: Copper Fin Thickness: 0.20 mm ` Al f' 1 • Print Date: August, 2015 Page 2 of 3 oc�too®iEo. Please verify certification is active on the SRCC website.� m Solar Rating & Certification CorporationT" www.solar-rating.org 400 High Point Drive, Suite 400 • Cocoa, Florida 32926 • (321) 213-6037 ♦ Fax (321) 821-0910 . ^.., .,�...,.�,,.,.�➢:�:ix^mil^ > `;a`Yin`Y�; T. ^T���. s i:'Y,'t•',-.vP'Y"i•'7�.:i•- `'?'•'�."'i'�,•�"."+.} Y�, />`Y /�,r-f� ;(y". '•`� .•".,^ _ !'l.�-_ � �t "ems •-,;r:t.'...� ?` :C�.c;:�.s�•c r„�`.t� .:-Z,:;,< r 'ram . �,.•t�i;,.n ���'%x�' �.' `C`�•C.,': .'c�.'�' �.'�..,.'�. .. �-1�" ��!! J�YYJ, :•,. SUPPLIER: _ Alternate Energy Technologies 1345 Energy Cove Court Green Cove Springs, FL 32043 USA www.aetsolar.com In Accordance with: SRCC Standard 100-2010-08 CERTIFIED SOLAR COLLECTOR BRAND: AlternateEnergy MODEL: AE-40 COLLECTOR TYPE: Glazed Flat Plate CERTIFICATION #: 10001820 Original Certification: April 16, 2013 Expiration Date: December 03, 2024 The solar collector listed below has been evaluated by the Solar Rating & Certification CorporationTM (SRCC"), an ISO/IEC 17065 accredited and EPA recognized Certification Body, in accordance with SRCC OG-100, Operating Guidelines and Minimum Standards for Certifying Solar Collectors, and has been certified by the SRCC. This award of certification is subject to all terms and conditions of the Program Agreement and the documents incorporated therein by reference. This document must be reproduced in its entirety. Flow Pattern: Parallel/Harp Number of Riser 10 Tube Spacing: 112.8 mm Number of times 1 Tubes: each riser crosses the absorber. Length of Flow Path: 2.96 m Riser to FIn/Plate Laser Weld Bond: INSULATION: Location Type Thlcimess Location Type Thidmess Back —Top Layer. Foam 35,6 mm Skies — Inner Layer. Foam 15.9 mm Badc — Bottom Layer None Sides — Outer Layer. None Enclosure Fastening Methods: Rivets Power Output per Collector(W) ( TI-Ta, G -1000 W/V J 0 10 30 50 70 2786 2586 2143 1643 10B4. PRESSURE DROP Flow AP Flow AP ml/s Pa gpm in Hz0 20 0 0.32 0.0 50 0 0.79 0.0 80 1 0 1.27 0.0 Print Date: August, 2015 Page 3 of 3 y Please verify certification is active on the SRCC website. © Solar Rating & Certification CorporationTM v www.solar-rating.org ♦ 400 High Point Drive, Suite 400 ♦ Cocoa, Florida 32926 ♦ (321) 213-6037 4 Fax 06-100 CERTIFIED ) 821-0910 •r �'7 ', a � SOLAR COULECTOR SOLAR COLLECTOR r� COMPON nEM NO. 1 AR VENT 2 BALL VALVE 3 BALLVALVI 4 BO1LER DRAI 5 BOILERDRAI 6 WTORRED 7 aRCLIATX)I a FREEZEPRO 9 GATE'SHUT 10 RELIEF VALE 11 RELIEF VA0 12 DIFFEM" HOT WATEF OUTLET q WATER JLET lCk THERMISTOR SENSOR COOLIE CAP SENSOR WIRE CHASE ROOF FLASHING :, Steca Elektronik GmbH 187700 Memmingen l Germany I Fan +49 (0) 8331 8558.0 i Fax +49 (0) 8331 8558.132 1 www.steca.com Steca TR 0301 U 3 inputs, 1 output The Steca TR 0301 U controller was specially developed for the North American market based on the Steca TR 0301 basic controller. With its:special certification (ETL label) from a Na- tionally Recognized Testing Laboratory (NRTU in the U5, the controller meets. the safety standards and minimum require- ments of the North American market, A feature of the Steca TR 0301 series of controllers is the animated graphic display, which offers a complete visualisa- tion of the solar energy system's operating status and solar .circuit. The clearly arranged display ensures easy operation using pic- tograms. The controller -was jointly designed with an inter- nationally renowned -design centre. The controller is used for monitoring and controlling solar thermal systems with -one collector array and one storage tank. In addition, the control- ler performs impoitant.system monitoring and safety func- tions to ensure safe -and long-lasting operation of the entire system. The numerous additional functions of the Steca TR 0301 U also include -a maximum storage tank temperature function, a tube collector function, an•anti-freezefunction, a holiday and storage retool function as well as a, choice of temperature indications in either degrees Celsius,(°C) or Fah- renheit (°F). The!operational safety of the system is supported by a sophisticated fault diagnosis. The multi -coloured LCD backlighting ensures quick and safe location of occurring er- rors and facilitates quick troubleshooting. The Steca TR 0301' U controller is supplied with a:pre-fitted US 'mains connection cable and a preinstalled, pluggable pump output. Product features ■ Compact,, multipart designereasing • Maximum storage tank temperature as, 'High level of operational safety through fault diagnosis ■ Temperature display 'C/'F ■ Collector overtemperature disconnection p Spring clamp terminals allow rapid and easy installation Displays as Graphical LCD display with backlighting ■ Animated representation of the systems and operating states Operation ■ Non-verbal menu navigation ■ Side switch for manual, auto, off Functions Y Holiday (storage tank retooling) ■ Interval / tube collector ■ Anti=freeze ac Display storage tank top arus.al apprrutron)• tlnpuuloutputsP-• Uar[ �ylllrj - 111ITi111110[1allal sift. _�_ - v - -�� - a _ _ •.. system voltage 120 V AC, 60 Hz �....- o0tional2_40VAC,60.Hz �s Ownconsumption _....... _. _ 1 WIs 0.001 HPIY.-�� _ .._..-._.- Inputs 3 3 x temperature (111000) Output 1 1 xswitch output relay (RI), max 400 W 10.5 HP (120 V AQ pr 800 W / 1 HP (240 V AQ Line cord 75 Inch, 3 x 18 AWG at 22.1 'F _ _ Tum•on temperature difference_ _ _ 8 K(46.4'FI Turn�oH lem_peralure_diHetence ..�� ^ _� 4 X139.2'FII Ambient temperatum _0 °C I+32 'FI •.. +45'C I+113'FI ___ Oagroeof protectian� _ IP 20/D;N 40050 Dimemions(XxYxZ) 160'x157x47mm 16.3 x 6.18 x 1.85 inchl _Weight Tamporatwe sensors 2 x Ptl000 Collector, sensor. 1.5 m (59, inchl slicane ublewith bushing (Measurng range up to + I WC 1+356'F01 Storage tank sensor. 0.3 m I11.8 inch► twisted single conductor Rat surface sensors with. compression cable lug (Measuring range up. to +105'C 1222'Fl) rChnkar data ar 25 T177'F Syawem withailastorpgetenk 1, collector array Internal heat exchanger, Into!Iigent pump control DESCRIPTION INSUL-TUBE° pipe insulation is ad environ- mentally -friendly, CFC-free, flexible elastomeric thermal insulation. it is black incolorand is available in unslit tubular formin wall thick> nesses of 3/8",1/2 3/4",111, 1-1/4'1-1/2" or 2" in sizes ranging from 3/8",I.D. to 8"'IPS. (Available In 6' lengths"and calls}. INSULT TUBE® key physical propedies'are approved through supervision by Factory Mutual Research Corporation. INSUL-TUBEm is non -porous; fiber -free and resists mold growth, An EPA -registered antimi- crobial agent is, incorporated intd the' product. providing additional protection Against mold, fungal and bacterial growth. _ INSUL TUBE®•is GREENGUARDIP certified as a low VOC material, meeting the requirements of the "Children &Schools"and "Indoor Air'Qual- ity" classifications: APPLICATIONS INSUL TUBED is used to retard heat gain and prevent condensation or frost formation on refrigerant lines, cold water plumbing, and chilled water systems. it also retards heat flow for hot water plumbing ;,6quid heating, dual temperaturepiping, and many- solar, systents. INSUL-TUBE°t is designed for the HVAC and Refrigeration industry. INSUL-TUBE® is recommended for applica- tions ranging from -2977 to 220OF(-1820C to 104%). The expanded closed-ce"ll-structure makes INSUL-TUBED an efficient insulator and provides effective moisture.vapor resistance. INSUL-TUBED can be used with. -heal tracing/ heat tapes. INSUL-TUBEO has a tough skin that,withstands tearing, rough'ltandling, and severe envi- ronmental conditions, yet is flexible, for easy installation. INSUL TUBED has superior cold weather flexibility. INSTALLATION With a factory -applied coating of talc on the smooth inner surface, I'INSUL-TUBE° slides easily over pipe or tubing for quick installation. When applied to existing lines, tubing is slit lengthwise and fitted into place. (Slitting can be done on the job with a sharp knife or pre -slit INSUL-TUBEe7-is available on request). All seams and butt joints should be seated with an approved contact adhesive, making sure both surfaces lobe joined are coated with adhesive, Fittingsare fabricated from miter -cut tubular sections, and cover,.flanges, etc., from INSUL- SHEETO. K-Fitr''factoryfabricated fittings are also available. ASTM C1710, Installation Guide for flexible Closed Cell foams, should be used as -an installation guide. OUTDOOR APPLICATIONS INSUL-TUSEm is.made from a UV resistant elastomeric blend. For moderate UV exposure (residential applications),.no additional protec- tion is needed. For severe.UV exposure. (rooftop applications) or optimum performance; K-FLEX° 374 Protective Coating, approved jacketing or K-FLEX Clad49 is required. UNDERGROUND For buried lines above the water table, use a clean fill such as. sand (3"-5" layer) to protect INSUL-TUBES before backfilfing. It is recom- mended that materials to be buried are properly sealed.at all seams and butt joints with an ap- proved contact adhesive, For optimum perform- ance, the lines should'be encased in a conduit to protect them from problems associated with ground water intrusion and compaction. RESISTANCE TO MOISTURE VAPOR FLOW The closed -cell structure and unique formulation of INSUL-TUBE" effectively retards the flow of moisture vapor, and is considered a low transmittance vapor retarder. For most indoor.. applications, INSUL-TUSEcl' needs no additional protection. Additional vapor barrier protection may be necessary for INSUL-TUBED when installed on low temperature surfaces that are exposed to continuous high humidity. FLAME AND SMOKE RATING INSUL-TUBEm in wall thicknesses of.2" (50 mm) and below has a flame spread rating of 25 or less and a smoke development rating of 50 or less as tested by ASTM E84, "Surface Burning Characteristics of Building Materials". INSUL-TUBE° is acceptable far-duct/plenum applications, meeting the requirements of.NFPA 9OA/B. Numerical flammability ratings.alone may not define the performance of products underactual fire conditions. They are provided only tar use in the selection of products to meet limits specified when compared to a known standard. K FLEX USA Mode In USA �� °�.Pau�T04 `ems► ".�» = . APPROVED-e.+�'r/'`.. a"��,�8> EN6U 1 Y f t a'iF(,G F::}x Y �•F�,,,x)-yY�Eyr?�Ff'�•,�j•.(-'`t3�a1 •-m- <`:iF-•Y t-.a.•:-..:u .Esd �ii R`i•�f 1`3f' 1 t r �rsn 1 ,£.a•a�. :i �3-.. rw ' I:Y' 4 �tk t4 +�- y�Mla jh' 1 1 •4fr4 t yy�� ,may .S j RYaela r rraa:e..anww.ru;..n•r •rr.n r-.•...,. �t+.; Iy. yr:-'•` ''� `.�z -_'� ,.tf'• m J kYr•t�: 1 _ 7r9'I10mmI. ,I:i'�r •. ac '_C.:. ng."��t2'iil7,j!dnl�°_•••+,:,' :• • 1%2� 1 min '::�1!%`Cfl':.t -(3. 7 Over 2-1r8"IIwTIPS 318"(10mm) 318'(10mmm) 12'S13mm) 314"(19mm) _ t4 acs� .r QW 4" In 12' (13 mm) I/!' (13 mml 3f4' 119 min) 314" (19 mm) -amrafp A na; atrrape�n4v�ap7e�axf• . _ . _ . ,. , .,..-._ - •r., .•...:. - �-_ ..:.:::• .....; ... .. ... 378' 10. th, wir to. - 314" (19 mm) 3/4' (19 mm) 1-12' (33 mm) 1-12- (32 min) Over a- Its I 3/4' (19 mml I 1' (25 mm) I 2' 150 mm) 1 2' (50 mm) INSIR 1119E' In Wckrf ss mled s Rhin the.specilied temperature eanges vnll prevent condensation on Indoor piping underdesign eoodkiens defined befpre Thkkness recommendallons above 2' can be sleeved f8 achievsr thickness deshed.ftarmaL Madmum severly of IndoereoodlUaw ralety weed grf 129'C) and 70% RJt in United States. 161d: Typval moons are most a ir-cond'dianed spars and grid climates- Sevfm. Centrally taund in areas 49M excessive moisture is inheduccd or invwlyvaeUlatadareasxhetalaerempuralmmaybe ieprasedbelow the ambient. Undereruditiamot high humiditj;ad0onallbunasorinsufatidnmaybe repuired NOTEThicknessrecommendations calcviatedusing 02575f-facia (0245 plus S%test anotalkwana). PIPE "R" VALUES PER SOME FOOT NOMINAL INSULATION I.O. 3/8" WALL 112" WALL '; t • N'WALL ' . 1" V1ALL 1-1/4" WALL 1-1/2" 2" 2" WALL Gall`3 K•sS'f{ Ni � 11- .0 .0 - ujy� ®® ®®Mmay® LNIN . 03 -' �a+xal rd, „ ...' °�-- rIw -• .�--s�'3 � � -:. 9 .. FER IR�' y1s�..i44 L' i`_• 3.:.- J 'ti.• N.l'R 1 . - h'^:L'f"5 ..3.i4�{`Cinw��i"�}�SSrA'''•-+. �l -�. �•ht12's®® „`ziy.J{-•'r'�rtiw{.Y�.vY•ONMEM �41�S7iYSWk'63SR'i•Ek. va ��y� ® �® ROOM,, OM,,M— ,�$�'�$T®�j.[q�a� . r� y-.Ylu Rk�Ys 9f1-(Mu Yi®rrcv.�. �i�• M ff - . -• ' ...... �i".y.PRt1�;$rY .-•'vi5 ; ' + l . .. } h;SR•il .l v�MWANN "`•i'? , . N¢t4'R' Ueiars nrte rstcul4led wing a H (attar a! 0265 (at 75•F, 24'C mean i¢mp.) end �cminii wall IAidmeis a each case. taxer cpenGng lemDereh+res xip mseN hl tmomvcd R values: Contact 7ectmicat Swiw rer steulie racammenealmns. _-r �.v� s:t�: r�sf_=E7i'r'.:f�:i �.L s.'•v �•1r: ,-h_. :l - .:✓-, a p�- 7Cr.,`��C���J�'S:Q; � - 4 T;z �:��;z[/�:•;�.;� ^:L: a v•::: .-c� .v y ✓ f si7:_ •,eC it arS1 f'•" ").'-'. � � - - •,�y%iF"t� � � SP �•.si .�o•�.�' S: a_Y•+'fA �b - 1 � 1 `"tY 1, ��+lR:i f.�le I,ri "i� 1J° sl •vi irh't :••..-..: fa4 4;tF �pn �• '47-�� 4• i k !ti tit �F ; a. , •.>< •, -. ,,�#-,!..,::�( 5�"��� DO.NBcU'p11d�`h'(riupg'��+ilfe•.N�175�96 1oljflP8,804 7,�:.;6;4`��,��?�$OU�5• ��'.2�-aYww�(ileXJsa:com":,•"' Y � ;�: si� . ; . ��•���' May 2010 K-TlI1f USA- IkSUL-11JBE° isa registered trademark 0� K-REl( USA Tlic GREENGUA$0' INDOOR AIR OUAl1T1' GERTIFIEO mzrN •INNOVATION IN INSUIJiTION is aregistered certification mark used uM1d¢r license through the GREE(70UARDm Environmental Institute. INOS-O30]-1211 clow-dUd.1GOlh + Cli: (B O). 01-95•113s PLASTIC PiL• (E00) 321-9532 0 Fax: (800) 321=9535 WATER HEATER PANS r 1 MAV.oatey.cor l SUBMITTAL SPECIFICATION Engineering Specification: oatey Plastic. Water Heater Pans can be installed under electric water Job Reference heaters to protect from water damage. Available with 1"'PVC or 1" CPVC drain,fittings to allow for connection to indirect drain. (All dimensions in inches) • Manufactured from 0.0625" plastic polymer ♦ 1" PVC or 1" CPVC drain fitting provided • • Pre-cut side opening accommodates drain fitting • For use with Electric Water Heater Tanks Meets requirements of Southern Building Code • Pan depth is 2.50" ♦ Vicat Softening Temperature is 1800 F ✓' Product No. Description Qty Inside Diameter A Outside 'Diameter B WATER HEATER PANS WITH 1" CPVC FITTING 34160 18" Plastic Water Heater Pan - Bulk 12 18 18.75 34161 20" Plastic Water Heater Pan - Bulk 12 20 21.25 34162 22" Plastic Water Heater Pan — Bulk 12 22 23.25 34163 24" Plastic Water Heater Pan - Bulk 12 24 24.50 34164 26" Plastic Water Heater Pan - Bulk 12 26 26.75 34168 29" Plastic,Water Heater Pan - Bulk 12 28 29.75 34165 30"Plastic Water Heater Pan - Bulk 12 30 31.00 WATER HEATER PANS WITH 1" PVC FITTING 34060 18"'Plastic Water Heater Pan - Hulk 12 18 18.75 34061 2W Plastic Water Heater Pan - Bulk 12 20 21.25 34062 22" Plastic Water Heater Pan - Bulk 12 22 . 23.25 34063 24" Plastic Water Heater Pan - Bulk 12 24 24.50 34058, 24" Plastic Water Heater Pan - Bagged. 6 24 24.50 34064 26" Plastic Water Heater Pan - Bulk 12 26 26.75 34072 28" Plasdc.Water Heater Pan - Bulk 12 28 29.75 34065 30" Plastic Water Heater Pan - Bulk 12 30 31.00 WATER HEATER PAN ADAPTERS 34086 1-1/2" PVC Adapter 12 34088 1" PVC Adapter 12 34089 1 1" CPVC Adapter 12 Data is subject to manufacturing tolerances. H-17 Visit..www.oatey.com for updates 10/2005 arr�er�c�n W A T E R H E A T Z R S Residential Electric Direct Solar Water Heaters 6-Year Limited Tank/6-Year Limited Parts Warranty* American direct solar watet heaters are designed for installation as a part .of a direct (open loop),solar water 'heating system or for use with external.heat exchangers in closed loop systems. Available in 65, 80 and 119-gallon capacities these models provide storage for the hot water produced by the solar collectors and a supplementary electric heating element that maintains consistent water temperature during periods when solar•energyis not available. Multiple Connection Options for Installation Flexibility • Side and top connections for open'loop systems,or closed loop'systems using anexternal heat:exchanger Electrical • 4506 watt heating -'element - long lasting low -watt density design spreads wattage over larger surface area to prolong element life and maximize efficiency • Pre -wired for surface mount temperature sensor (sensor supplied separately) Tank Construction • Glasslined Steel Tank—glasslining protects against corrosion to maximize tank life • 2-1nch thick "Environmentally-F.riehdly"Non-CFCFoam Insulation_(R16Val ue) reduces standby heat.loss Anode Rod • Aluminum anode rod with�stainless steel core protects tank against corrosion CSA Certified' and ASME Rated T&P Relief Valve DurableTamper-Resistant Brass Drain -Valve Compliance • Units are UL and cOL listed to UL 174 Standard for Household Electric Storage Tank Water Heaters and'CAN/CSA-C22.2 No. 110=M90, Complies with California legislation AB T953 and VermontlegislationAct 193 that limits the lead content In plumbing fixtures that come into contact with drinking water to a maximum of 0.25%: Standard 6Year-LimitedTank, and Parts Warranty • Optional 10-year extension on tank warranty when used in a residential application • 3-year tank and 1-year partswarranty.when installed in commercial application • For complete warranty'Information'consult written warranty supplied with 'the product, online at-www.americanwaterheater.'com,. or call American Water H:eatersat 800.45.6.9805 Eligible fora 30%federal tax credit When installed, as part of a complete -'solar water -heating system. For more information visit www,am erkanwaterheater.com. Copyright-! by American, water Heaters 2012, Ail rights reserved. NCESS00708 R January 2012 Ne putolthltwyt nugbt @DradeRda lnmmined leant' farmabyinymtdnt. ebrlrtnlydr mrrhSnlr�C IndadNp phatompylnq and retardlnp, u by ady Wmmatlan storage retdrial sntrm without p[rmbslen tnwittlnpfrom Amn¢anWaterHrolits. Residential Electric Direct Solar Water Heaters W A T E R H e A T e K .s UPPERACCESS HOT COLD LOCATION PANEL 4SOD WATT 'HEATING ELEMENTO q Q O ANODE �CCOStOLARN—~O® SOLAR COLLECTORS COLLECTORS FLOW . SOLARCOLLECfORS C COLD RETURN. LOWER ACCESS PANEL To SOLAR TEMPERATURE SENSOR FLOW COLLECTORS MOUNTING ME) p IDRAIN VALVE aumited warranty on tank and parts5ee written warranty supplied with the water heater for complete details. " All solar loop and domestic water connections are 3/4' NPr. Top solarloop and domesticwater connections are male NPT with factory -installed dielectric pipe nipples. 51de solar loop connections are female NPT and.are plugged from the factory. Specification Furnish and Install, where indicated, In accordance with manufacturer's instructions and In compliance with all rules and regulations of authorities having jurisdiction. Storage tank(s) shall be American, Model as manufactured by American Water Heaters or equivalent. Storage tank(s) shall have a nominal storage.capacity of galloni, recovery of GPH at ' F temperature rise and supplied with auxiliary heating elementsrated at 4.5 KW, volt:Storage tanks) are hydrostailc tested'at 300 PSI having a working pressure of 150 PSI and shag have a fused Ceramic Shield Internally lined tank applied under pressure and fired at 16OW F allowing formaximum protection. Storage lank(i) shall be equipped with an'approved pressure and temperature relief valve.The outer Jacketing shall have a baked enamel finish. The tank shall be foam Insulated with an EPA -approved, non-CFC material 2' In thickness. Storage tank(s) shall have a 6-year limited warranty against corrosion as outlined in the written warranty. Distributed By: Order Entry and Sales Warranty and Service 500 Princeton Road (FEDEX, UPS) 500 Princeton Road (FEDEX, UPS) Johnson City, TN 37601-2030 Johnson City,TN 37601-2030 P.O. Box 4808 (Mailing) P,O. Box 1597 (Mailing) Johnson City, TN 37602-4808 Johnson City,TN 37605-1597 (800) 937-1037 (800) 456-9805 FAX (800) 581-7224 FAX (800) 999-5210 NCESS00708 No pan d Ihh ivorkmay be frprodueed oe Usnsmined In or firm of 6r any means, eleabonie of muludiaLInduding photocopying and nmidin; or by toy inramddon storage ift ierai system, without ptrmktion inwriting from AmreianVfalrf Nealte" Submittal Data Information 101-066 Iffiarmowco Plumb `n' Plug® Domestic Hot Water Circulators EFFECTIVE: February 14, 2014 SUPERSEDES: March 1, 2011 ENGINEER ITEM NO. MODEL NO. General Product Information: Taco Plumb n' Plug® (PNP) Circulators periodically recirculate hot water through the domestic water piping system to decrease the delivery time to outlet fixtures and reduce wasted water. These UL-listed units feature quiet, efficient operation and low power consumption. Self lubricating, with no mechanical seal and Taco's unique replaceable cartridge design, Plumb n' Plug® circulators are field serviceable and maintenance free. An optional Aquastat is available for constant circulation applica- tions to maintain temperature between 95OF and 115°F. Features: • UL Listed • Optional 95°F -115OF Aquastat Available • Standard High Capacity Output • Compact Design • Quiet, Efficient Operation • Direct Drive - Low Power Consumption • Unique Replaceable Cartridge Design - Field Serviceable • Self Lubricating • No Mechanical Seal • Unmatched Reliability - Maintenance Free • Sweat Connections - Bronze • Union & Threaded Connections - Stainless Steel • Flanged - Stainless Steel Model Nomenclature: BC - Bronze, 'h" Sweat B - Bronze, 3/4" Sweat ST - Stainless Steel, 3/4" FNPT SC - Stainless Steel, Union Connection SF - Stainless Steel, Flanged PNP - Plumb n' Plug® Electrical Data: MODEL VOLTS Hz Ph AMPS RPM HP 003-PNP 115 60 1 0.45 3250 1/40 005-PNP 0.54 006-PNP 0.52 006-PNP (IFC) 0.57 Motor Type Permanent Split Capacitor, Impedance Protected CONTRACTOR Performance Data: REP. Flow Range: 0 - 7 GPM (003), 0 - 19.5 GPM (005) 0 - 11.5 GPM (006) Head Range: 0 - 4.5 Feet (003), 0 - 8.5 Feet (005) 0 - 9.5 Feet (006) Minimum Fluid Temperature: 40OF (4°C) Maximum Fluid Temperature: 220°F (1040C) Maximum Working Pressure: 125 PSI Materials of Construction: CIRCULATOR: Casing (Volute): Bronze or Stainless Steel Stator Housing: Steel Cartridge: Stainless Steel Impeller: Non -Metallic Shaft: Ceramic Bearings: Carbon 0-Ring & Gaskets: EPDM INTEGRAL FLOW CHECK (IFC): Body & Plunger: Acetal Spring: Stainless Steel O-Ring: EPDM Mounting Positions: STANDARD OPTIONAL OK IF OVER PSI NSF DS Fe -smart �� Ns Nss�2 LISTED A Taco resource — saving product ANALOG TIMER OPTION: Application: The Plumb n' Plug with analog timer will cycle the circulator dur- ing peak usage periods such as early morning or early evening. An optional aquastat is available for constant circulation applications to maintain temperature between 950F and 115°F. The Taco 003 PNP is ideal for recirculation loops. Its design operating condition of 3 gpm at 3 feet of head helps to reduce erosion, corrosion and noise in system piping. Use the 003 PNP for systems up to 200 total feet (supply and return) of 3/4" pipe. The Taco 005 and 006 PNP is designed for systems using 200-400 feet of 3/a" pipe. Installation of isolation valves, pipe insulation and flow checks are recommended. Pump Dimensions & Weights: Analog Features: • 24 Hour Analog Timer • 15 Minute ON/OFF intervals • Easy -to -Use Clock Timer • Factory installed 6' line cord ANALOG TIMER MODEL CONNECTION A B C D E F SHIP WGT. IN. mm IN. mm IN. mm IN. mm IN. mm IN. mm LBS. KG 003-BC4-PNP '/2" Sweat 7'/a 184 115/,e 49 2'/6 54 3Y,6 77.8 51/4134 36/�6 84 7.0 3.2 003-134-PNP 3/a" Sweat 23/,6 56 003-ST4-PNP %" FNPT 2 51 003-SC4-1 PNP Union 23%2 76 6 152 005-SF2-PNP SS Flanged 81/e 205 3%2 80 3%2 78.6 4% 121 6% 162 006-BC4-PNP '/2" Sweat 7'/a 184 2'/6 54 3'/ie 77.8 51/4134 35/i6 84 006-134-PNP W Sweat 23/,6 56 006-ST4-PNP 3/a" FNPT 2 51 006-SC4-1PNP Union 23A2 76 6 152 ANALOG TIMER with INTEGRAL FLOW CHECK (IFC)® MODEL CONNECTION A B IC D E F SHIP WGT. IN. mm IN. mm IN. mm IN. mm IN. mm IN. mm LBS. KG 003-BC4-3PNP '/2" Sweat 81/e 205 116/16 49 23 /16 56 3'/,s 77.8 55/435/, 134 6 84 7.0 3.2 003-BC4-2PNP %" Sweat 005-SF2-IPNP SS Flanged 3%2 80 3%2 78.6 4% 121 6% 162 006-BC7-1 PNP '/2" Sweat 23/16 56 3'/16 77.8 51/4134 36/ie 84 006-BC7-PNP 3/a" Sweat DIGITAL TIMER OPTION: �J Application: The Plumb n' Plug with Digital Timer allows ON/OFF program settings to fit any homeowner's schedule. Multiple settings allow for different weekday/weekend run times. Run time intervals can be set as short as 1 minute to maximize energy savings. Easy - to -Use clockface and large LCD display make settings a snap. Its onboard capacitor retains settings in memory for up to 2,500 hours during power outages. An optional Aquastat is available for constant circulation applications to maintain temperature between 950F and 115°F. Taco 003 PNP is ideal for recirculation loops. Its design operating condition of 3 gpm at 3 feet of head helps to reduce erosion and noise in system piping. Use the 003 PNP for systems up to 200 total feet (supply and return) of W pipe. Installation of isolation valves pipe insulation and flow checks are recommended. Pump Dimensions & Weights: Digital Features: • Digital Timer - 7 Day Programmable • Large LCD Display • Easy -to -Use Program Buttons • ON/OFF Intervals as short as 1 Minute • 2,500 Hour Capacitor Backup, Saves Settings MODELS 003-PNP and 006-PNP A B D E I - - MF MALE 6ft. CORD THREAD DIGITAL TIMER MODEL CONNECTION A B C D E F SHIP WGT. IN. mm IN. mm IN. mm IN. mm IN. mm IN. mm LBS. KG 003-BC4-8PNP '/2" Sweat 7'/4 184 115/16 49 2'/e 54 3'/16 78 5'/4 134 Vi6 84 7.0 3.2 003-134-2PNP %" Sweat 23/1e 56 003-ST4-2PNP W FNPT 2 51 003-SC4-3PNP Union 23%2 76 6 152 006-BC4-4PNP '/2" Sweat 2'/8 54 5'/4 134 006-84-2PNP W Sweat 23/16 56 006-ST4-2PNP W FNPT 2 51 006-SC4-3PNP Union 231/2 76 r 6 152 DIGITAL TIMER with INTEGRAL FLOW CHECK (IFC)o MODEL CONNECTION A B C D IE F SHIP WGT. IN. mm IN. mm IN. mm IN. mm IN. mm IN. I mm LBS. KG 003-BC4-1 1 PNP '/2" Sweat 8'/e 205 115/�e 49 23/�e 56 3'/e 78 5'/4 134 35/�s 84 7.0 3.2 003-BC4-10PNP W Sweat 006-BC7-5PNP 1/2" Sweat 006-BC7-4PNP 1 3/4" Sweat LINE CORD ONLY OPTION: Application: For recirculation systems setup for constant circulation or with an optional aquastat control, use Plumb n' Plug® with line cord only. Simply plumb it in and plug it in. Taco 003 PNP is ideal for recirculation loops. Its design operating condition of 3 gpm at 3 feet of head helps to reduce erosion and noise in system piping. Use the 003 PNP for systems up to 200 total feet (supply and return) of 3/4" pipe. Installation of isolation valves, pipe insulation and flow checks are recommended. Pump Dimensions & Weights: MODELS 003-PNP and 006-PNP with LINE CORD ONLY LINE CORD ONLY MODEL CONNECTION A B C D E F SHIP WGT. IN. mm IN. mm IN. mm IN. mm IN. mm IN. mm LBS. KG 003-BC4-4PNP 1/2" Sweat 51/s 130 41/s 105 23/,s 56 3Y,s 78 41%2 112 35/�s 84 6.5 2.9 003-64-1 PNP W Sweat 51/s 130 41/s 105 21/8 54 41/4 108 003-ST4-1 PNP W FNPT 5% 143 47/s 124 2 51 4 102 003-SC4-2PNP Union 5%2 1 131 4/32 110 231/32 76 515/,s 151 006-BC4-2PNP 1/2" Sweat 5Ys 130 41/s 105 23/,s 56 41%2 112 006-B4-1 PNP W Sweat 5Ys 130 4Ya 105 21/s 54 41/4 108 006-ST4-IPNP %" FNPT 5% 143 47/s 124 2 51 4 102 006-SC4-2PNP Union 5%2 131 411/32 110 23%2 76 515/16 151 LINE CORD ONLY with INTEGRAL FLOW CHECK (IFC)® MODEL CONNECTION A B C D E F SHIP WGT. IN. mm IN. mm IN. mm IN. mm IN. I mm IN. mm LBS. I KG 003-BC4-7PNP 1/2" Sweat 6 152 4'/6 124 23/�s 56 2's/,s 75 43/e 111 3s/,e 84 6.5 2.9 003-BC4-6PNP 3/4" Sweat 006-BC7-3PNP 1/2" Sweat 006-BC7-2PNP W Sweat PERFORMANCE FIELD INFORMATION (60 Hz) 12 11 10 9 8 W uW 7 = 6 5 O 4 3 2 1 0 DOMESTIC WATER RECIRCULATION MODELS (STD) FLOW-M'/H 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 3.5 3.0 2.5 y 2.0 O�Q W 1.5 O 1.0 0.5 0 2 4 6 8 10 12 14 16 18 200.0 FLOW -GPM 003 005 006E 3 2 1 DOMESTIC WATER RECIRCULATION MODELS (IFC) FLOW-M'/H 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 10 9 8 7 L YW. 6 O = 5 O 4 R 3 2 1 0 003-IFC 005-IFC 006E-IFC 3.0 2.5 3 2 2.0 1 1.5 1.0 n_s 0 2 4 6 8 10 12 14 16 18 20 FLOW -GPM 0 oC W H W O I - Do your best work.® Printed in USA TACO, INC., 1160 Cranston Street, Cranston, RI 02920 Telephone: (401) 942-8000 FAX: (401) 942-2360. Copyright2014 TACO (Canada), Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T OJ8. Telephone: 905/564-9422. FAX: 905/564-9436. TACO, Inc. Visit our web site at: http://www.taco-hvac.com