HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFING� T4W
BCIS Home } Log In } User Registration Hot Topics } Submit Surcharge Stats & Facts Publications } FBC Staff BCIS Site Map ' Links } Search }
b
dbalk
-
iS} Product Approval
�'J,. • USER: Public User
dr
Product Approval Menu > Product or Aoollcation Search > Application List > Application Detail
FL # FL17022-R6l1
Application Type Revision
Code Version 2014 R3,1
Application Status Approved AUG r- ;7u al?
PERMtI TTiitiG
Comments St. Lucie Cetlniy, FL
Archived Ci
Product Manufacturer Extreme Metal Fabricators, LLC.
Address/Phone/Email 2160 SW Poma Drive i
Palm City, FL 34 90
(772)872-8034
tara@extrememetalfabrica Irs-col,
L 'a ` i P
�r
Authorized Signature James Buckner
jimmy@cbuckinc.net
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
rchard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category
Roofing
Subcategory
Metal Roofing
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
M- Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
James L. Buckner, P.E. @ CBUCK, Inc.
the Evaluation Report
Florida License
PE-31242
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date
04/22/2024
Validated By
Michael John Riemer, P.E.
2 Validation Checklist - Hardcopy Received
Certificate of Independence FL17022 R6 COI CertOfIndep.pdf
Referenced Standard and Year (of Standard) Standard Year
TAS 125 2003
UL1897 2004
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
10/21/2016
Date Validated
12/29/2016
Date Pending FBC Approval
10/24/2016
Date Approved
01/O1/2017
Summary of Products
FL #
Model, Number or Name
Description
17022.1
1 - "5V Crimp" (116)
26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically
attached to Wood Deck with screws
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R6 II 1 SVCrimp 26oa WoodDeck EVALREPORT R6.pdf
Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. #31242
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions
FL17022 R6 AE 1 SVCrimp 26oa WoodDeck EVALREPORT R6.odf
Created by Independent Third Party: Yes
and limitations of use. Install the assembly in
compliance with the Installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
17022.2
2 - "5V Crimp" (R6)
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel,
mechanically attached to wood deck with exposed screws.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R6 II 2 SVCrimp 032A1um WoodDeck EVALREPORT R6.odf
Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. #31242
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions
FL17022 R6 AE 2 SVCrimp 032A1um WoodDeck EVALREPORT R6.pdf
Created by Independent Third Party: Yes
and limitations of use. Install the assembly in
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
17022.3
3 - "1.5" Mechanical Seam"
1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel
(115)
mechanically attached to wood deck with clips and screws.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R6 II 3 1.5 MechSeam 24ga WoodDeck EVALREPORT.odf
Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. #31242
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions
FL17022 R6 AE 3 1.5 MechSeam 24ga WoodDeck EVALREPORT.pdf
Created by Independent Third Party: Yes
and limitations of use. Install the assembly In
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
17022.4
4 - "1.5" Mechanical Seam"
1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel
(115)
mechanically attached to wood deck with clips and screws.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R6 II 4 1.5
Approved for use outside HVHZ: Yes
MechSeam 032A1um WoodDeck EVALREPORT,odf
Impact Resistant: No
Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. #31242
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions
Evaluation Reports
and limitations of use. Install the assembly in
FL17022 R6 AE 4 1.5
compliance with the installation method listed in
MechSeam 032A1um WoodDeck EVALREPORT.odf
this report and applicable code sections of FBC.
Created by Independent Third Party: Yes
Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
17022.5
5 - "1 in. Nail Strip" (115)
1" rib height, 16" wide, 26 gauge steel, standing seam roof panel
mechanically attached to wood deck with screws.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R6 II 5 INailStrip 26ga WoodDeck EVALREPORT.pdf
Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. #31242
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions
and limitations of use. Install the assembly in
FL17022 R6 AE 5 INailStrip 26ga WoodDeck EVALREPORT adf
Created by Independent Third Party: Yes
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
17022.6
6 - "1 in. Nail Strip" (R5)
1" rib height, 16" wide, 0.032" aluminum, standing seam roof panel
mechanically attached to wood deck with screws.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R6 II 6 1NailStrip 032A1um WoodDeck EVALREPORT.pdf
Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. #31242
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions
FL17022 R6 AE 6 INailStrig 032A1um WoodDeck EVALREPORT.p_df
Created by Independent Third Party: Yes
and limitations of use. Install the assembly in
compliance with the installation method listed in
this report and applicable code sections of FBC.
-Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
17022.7
7 - "1.5 in. Nail Strip" (115)
1.5" rib height, 19" wide, 26 gauge steel, standing seam roof panel
mechanically attached to wood deck with screws.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R6 II 7 1.5NailStrip 26ga WoodDeck EVALREPORT.pdf
Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. #31242
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions
FL17022 R6 AE 7 1.Mai(Strip 26ga WoodDeck EVALREPORT,pddf
Created by Independent Third Party: Yes
and limitations of use. Install the assembly in
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
17022.8
8 - "EMAX Rib" (R5)
29 gauge steel, lapped roof panel mechanically attached to wood deck
with exposed screws.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R6 II 8 EMAX Rib 29ga WoodDeck EVALREPORT.pdf
Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. #31242
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions
FL17022 R6 AE 8 EMAX Rib 29ga WoodDeck EVALREPORT.p_df
Created by Independent Third Party: Yes
and limitations of use. Install the assembly in
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
17022.9
9 - " PBR MAX" (115)
26 gauge steel, lapped roof panel mechanically attached to wood deck
with exposed screws.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R6 II 9 PBR Rib 26ga WoodDeck EVALREPORT.odf
Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. #31242
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Parry: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions
FL17022 R6 AE 9 PBR Rib 26ga WoodDeck EVALREPORT.Ddf
Created by Independent Third Party: Yes
and limitations of use. Install the assembly in
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
Back Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Stateme
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 4S5.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 4S5, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 4SS, F.S., please
click here .
Product Approval Accepts:
�„^'. eCle� M
Credit Card
Safe
CBUCK Engineering
Speclaltly Structural Englneering
Evaluation Report
1" Nail Strip
Metal Roof Assembly
Manufacturer:
CBUCK, Inc. Certificate of Authorization #8064
Extreme Metal Fabricators, LLC.
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
for
Florida Product Approval
# FL 17022.5 R5
Florida Building Code Sth Edition (2014)
Method: 1- D
Category:
Sub - Category:
Product:
Material:
Panel Thickness:
Panel Width:
Panel Seam:
Support:
Prepared by:
James L. Buckner, P.E., SECB
Florida Professional Engineer # 31242
Florida Evaluation ANE ID: 1916
Project Manager: Youry Demosthenes
Report No. 16-123-1NS-S6W-ER
(Revises 15-217-1NS-S6W-ER)
Date: 4 / 18 / 16
Contents:
Evaluation Report Pages 1— 7
Roofing
Metal Roofing
1" Nail Strip Roof Panel
Steel
26 gauge
16"
Snap -Lock
Wood Deck
Digitally signed by James L. Buckner, P.E.
Electronically signed and sealed documents
shall comply with the provisions of FAC Rule
61G15-23.\\1k%IIIIII11!!
* ' No 31242
�� * w=
�0,�'• STATE OF
�i �•••'•.FLORIDP •'•. ���
S ..
5/O N Al-��
�!I/llllll►�`
/
S
2016.04.1911:32:32-04'00'
CBUCK, Inc. - Palm Beach County, Florida
Phone: (561) 491-9927 - Email: cbuck@cbuckinc.net • Website: www.cbuckinc.net
Mail Address: 2637 E. Atlantic Blvd, #34069, Pompano Beach, FL 33062
-- / FL #: FL 17022.5 R5
Date: 4 / 18 / 16
CE3UCK Engineering Page
No.: 26of INS-S6W-ER
Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064
Manufacturer:
Product Name:
Product Category:
Extreme Metal Fabricators, LLC.
1" Nail Strip
Roofing
Product Sub -Category Metal Roofing
Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d)
Product/System 1" Nail Strip Roof Panel, 26 Gauge steel, 16" wide panel mechanically attached to
Description: Wood Deck
Product Assembly as Refer to Page 4 of this report for product assembly components/materials &
Evaluated: standards:
1.
Roof Panel
2.
Fasteners
3.
Adhesive (select system)
4.
Underlayment
5.
Insulation (Optional)
Support: Type:
Wood Deck
(Design of support system is outside the scope of this evaluation.)
Description:
• 15/32" or greater plywood,
• or Wood plank (min. specific gravity of 0.42)
Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2,
applicable code sections and in accordance with manufacturer's
recommendations.
Performance: Wind Uplift Resistance:
• Design Uplift Pressure (ASD): Refer to Table A
(Refer to "Table A" attachment details herein)
l
CBUCK Engineering
FL M FL 17022.5 R5
Date: 4 / 18 / 16
Report No.: 16-123-INS-S6W-ER
Page 3 of 7
Specllalhj Structural Engineering CBUCK, Inc. Certificate of Authorization #8064
Performance Standards: The product described herein has demonstrated compliance with:
• UL580-06 — Test for Uplift Resistance of Roof Assemblies
• UL 1897-04 — Uplift test for roof covering systems
Code Compliance: The product described herein have demonstrated compliance with the performance
standards listed above as referenced in the current Florida Building Code.
Evaluation Report This product evaluation is limited to compliance with the structural requirements
Scope: of the Florida Building Code, as related to the scope section to Florida Product
Approval Rule 61G20-3.001.
Limitations and • This evaluation report for "Optional Statewide Approval' contains technical
Conditions of Use: documentation, specifications and installation method(s) which include
"Limitations and Conditions of Use" throughout the report in accordance with
Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is
the authority to approve products under "Optional Statewide Approval'.
• Option for application outside "Limitations and Conditions of Use"
• Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval
by the local authorities having jurisdiction in accordance with the alternate
methods and materials authorized in the Code". Any modification of the product
as evaluated in this report and approved by the Florida Building Commission is
outside the scope of this evaluation and will be the responsibility of others.
• This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to
comply with Florida product approval rule (FAC) 61G20-3. This evaluation report
is part of the Florida Building Commission approval for the listed code related
criteria. This report by James Buckner, P.E. and CBUCK Engineering is not a
design certification of code compliance construction submittal documentation,
per FBC section 107, for any individual structure, site specific or permit design.
• Deck shall be in compliance with applicable building code.
• Design of support system is outside the scope of this report.
• Fire Classification is outside the scope of Rule 61G20-3, and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade & Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005 (3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA
1824).
CBUCK Engineering
Specialty Structural Engineering
Components/Materials
(by Manufacturer):
Roof Panel:
Material:
Thickness:
Panel Widths:
Rib Height:
Yield Strength:
Corrosion Resistance
Fastener:
Type:
Size:
Corrosion Resistance:
Standard:
Seam Adhesive/Sealant:
Product Name:
Type:
Application Size:
Application Location:
FL #: FL 17022.5 R5
Date: 4 / 18 / 16
Report No.: 16-123-INS-S6W-ER
Page 4 of 7
CBUCK, Inc. Certificate of Authorization #8064
1" Nail Strip
Steel
26 Gauge (min.)
16" (max.) Coverage
1"
50 ksi min.
In compliance with FBC Section 1507.4.3:
• ASTM A792 coated, or
• ASTM A653 G90 galvanized steel
Pancake -Head Wood Screw
#10 x 1" (min.)
Per FBC Section 1506.6 and 1507.4.4
Per ANSI/ASME B18.6.1
(Select Systems)
Bostik 915T11 Chem -Chalk
One component, polyurethane adhesive
3/16" continuous bead
Along base of male rib vertical flange at each panel
seam. (Refer to Table "A" and drawing Pg 6-7)
Components/Materials: Underlayment:
(by Others): Material and application shall be in compliance with FBC Section 1507.4.5.1 and
1507.4.5.2, applicable codes and in accordance with manufacturer's
recommendations.
Insulation (Optional):
Type:
Thickness:
Properties:
Density:
Or Compressive Strength:
Rigid Insulation Board
3" (max.)
2.25 pcf (Ibs/ft3) min.
20 psi min.
Insulation Notes:
• Rigid Insulation shall meet minimum density OR compressive strength.
• Insulation shall comply with FBC Section 1508. When insulation is
incorporated, fastener length shall conform to penetrate thru bottom of
support a minimum of 3/16".
CBUCK Engineering
/ FL #: FL 17022.5 R5
Date: 4 / 18 / 16
Report No.: 16-123-INS-S6W-ER
Page 5 of 7
Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064
Installation: Installation Method:
(Refer to "TABLE A" below and drawings at the end of this evaluation report.)
■ Fastener Spacing: Refer to "TABLE A" Below
(along the length of the panel)
■ Rib Interlock: Snap -Lock
(Panel ribs shall be fully engaged to form an integral snap -lock.)
■ Seam Adhesive: Refer to Table "A" & Drawing Page 6.
(Apply continuously along base of male rib vertical flange at each panel
seam.)
■ Minimum fastener penetration thru bottom of support, 3/16".
■ For panel construction at the end of panels, refer to manufacturer's
instructions and any site specific design.
TABLE "A"
ALLOWABLE LOADS
METHOD 1
METHOD 2
Design Pressure (ASD)*:
- 86 PSF
- 97.25 PSF
Fastener Spacing:
6" o.c.
6" o.c.
Seam Adhesive:
Not required
3/16" continuous bead
(Refer to pg. 6-7)
* Allowable design pressure(s) for allowable stress design (ASD) with a margin of safety of 2 to 1.
Install the 1" Nail Strip roof panel assembly in compliance with the installation
method listed in this report and applicable code sections of FBC 5th Edition (2014).
The installation method described herein is in accordance with the scope of this
evaluation report. Refer to manufacturer's installation instructions as a
supplemental guide for attachment.
Referenced Data: 1. UL 580-06 & UL 1897-04 — Uplift Test
By Architectural Testing, Inc. - West Palm Beach, FL
(FBC Organization #TST ID: 1527)
Report No. D8133.01-450-18, Date: 06/30/15, Specimens #1 & #2
2. Quality Assurance
Keystone Certifications, Inc. (FBC Organization ID# QUA 1824)
Extreme Metal Fabricators, Inc. Licensee #974
3. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
FL #: FL 17022.5 R5
Date: 4 / 18 / 16
CBUCK Engineering Page Report No.: 6 -1 INS-S6W-ER
Speclalfiy Structural Englneprinq CBUCK, Inc. Certificate of Authorization #8064
Installation Method
Extreme Metal Fabricators, LLC.
1" Nail Strip (26 Gauge Steel) Roof Panel attached to Wood Deck
Drawings
16"
Panel Profile
16" o.c.
3/4"
—i
Deck:
-15/32" or greater Plywood, or
- Wood plank
Integral Snap Lock
For METHOD 2:
Apply 3116" Bead Bostik 915Tm Sealant
Continuous Along Male Rib Vertical Flange
Fastener
#10 X 1" Min. per Table "A"
Pancake Head Wood Screw
Typical Assembly Profile View
(Typical Fastening Pattern Across Width)
r'
`fL #: FL 17022.5 R5
Date: 4 / 18 / 16
Report
No.: Hof-INS-S6W-ER
CBUCK Engineering Page
IN
Specialty Structural Englneering CBUCK, Inc. Certificate of Authorization #8064
Installation Method
Extreme Metal Fabricators, LLC.
1" Nail Strip (26 Gauge steel) Roof Panel attached to Wood Deck
Fastener
#10 X 1" Min. per Table "A"
Pancake Head Wood Screw
1" Nail Strip Roof Panel
4/
Optional:
Rigid Insulation
Thickness 3" Maximum
LSeam Adhesive Application:
Deck: For Method 2
-15/32" or greater Plywood, or Apply 3116" Bead Bostik 915Tm Sealant
- Wood plank Continuous Along Male Rib Vertical Flange
(Refer to Table "A")
Typical Roof Assembly
Isometric View
(Optional) Rigid Insulation Board per Page 4 of this report
TABLE "A"
ALLOWABLE LOADS
METHOD 1
METHOD 2
Design Pressure (ASD)*:
- 86 PSF
- 97.25 PSF
Fastener Spacing:
6" o.c.
6" o.c.
Seam Adhesive:
Not required
3/16" Continuous Bead
* Allowable design pressure(s) for allowable stress design (ASD) with a margin of safety of 2 to 1.