HomeMy WebLinkAboutPRODUCT APPROVAL - MODIFIED BITUMEN ROOF SYSTEM8/23/2017 Florida Building Code Online
�. r as ;� 1
iy�u�fi�t�z-s�_r..�`4�.a`+k
BCIS Home Log In User Registration Hot Topics Submit Surcharge E Stats & Facts Publications I FBC Staff BCIS Site Map E Links Search
lodda h
-� ., Product Approval
' o
USER: Public User
n� F Product Approval Menu > Product or Application Search > Application List > Application Detalll RECEIVE®
al
-11.1 tp -4 FL # FL1654-R21 AUG 3 0 2017
ST . � -, .*r, Pe s� i
Application Type Revision
Code Version 2014 PERMITTING
Application Status Approved St. Lucie County, FL
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 150 Lyon Drive
Fernley, NV 89408
(570) 384-1230 Ext242
jakins@polyglass.com
Authorized Signature James Akins
jakins@polyglass.com
Technical Representative Maury Alpert
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(912) 429-8610
MAIpert@polyglass.com
Quality Assurance Representative
Address/Phone/Email
I
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
• Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
1
James Akins
555 Oakridge Road
Humboldt Industrial Pkwy
Hazleton, PA 18201
(800)894-4563
jakins@polyglass.com
Roofing
Modified Bitumen Roof System
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
ED Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
UL LLC
10/06/2018
John W. Knezevich, PE
u Validation Checklist - Hardcopy Received
FL1654 R21 COI 2017 01 COI Nieminen.odf
Standard
Year
ASTM D6162
2000
ASTM D6163
2000
ASTM D6164
2005
ASTM D6222
2008
ASTM D6509
2009
FM 4470
1992
htti)s://www.floridabuildinq.orq/pr/pr app dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUPv2pw6pKxAhWCSggoYjwjS%2fTJu%2blyo5uA%3d%3d 1/2
8/23/2,017
Florida Building Code Online
FM 4474 2004
UL 1897 2008
Equivalence of Product Standards
Certified By
°
Sections from the Code
Product Approval Method
Method 1 Option D
Date Submitted
06/01/2017
Date Validated
06/08/2017
Date Pending FBC Approval
06/14/2017
Date Approved
08/08/2017
Summary of Products
FL #
Model, Number or Name
Description
1654.1
Polyglass SBS and APP Modified
SBS and APP modified bitumen roof systems
Bitumen Roof Systems
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL1654 R21 II 2017 05 FINAL Al ER POLYGLASS MODBIT FL1654-
R21.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
other: 1.) The design pressure in this application
relates to one particular assembly over concrete
Evaluation Reports
FL1654 R21 AE 2017 05 FINAL ER POLYGLASS MODBIT FL1654-
R21.odf
deck. Refer to the ER Appendix for other systems and
deck types. 2.) Refer to ER, Section 5 for other Limits
Created by Independent Third Party: Yes
of Use.
BacK Next
Contact Us :: 2601 Blair Stone Road. Tallahassee Fl. 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 state of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your a -mall address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 45S, F.S.,
please click here .
Product Approval Accepts:
ram,. 911 ® EChEck -7:'v:
hftns://www_floridabuildina.ora/or/or aDD dtl.asDx?Daram=wGEVXQwtDavoau2w%2bnFpUPv2pw6i)KxAhWCSggoYjwjS%2frJu%2b1yo5uA%3d%3d 212
FUNI"jYIERD
EVALUATION REPORT
Polyglass USA, Inc.
150 Lyon Drive
Fernley, NV 89408
(570)384-1230
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization #9503
353 Christian Street
Oxford, CT 06478
(203) 262-9245
Evaluation Report P9290.02.08-1119
FL1654-R21
Date of Issuance: 02/11/2008
Revision 19: 05/30/2017
SCOPE:
This Evaluation Report is issued under. Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 5th Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6, plus a 56-page Appendix.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59156, Florida DCA ANE1983
The facsimile seal appearing was authorized
by Robert Nieminen, P.E. on 05/30/2017
This does not serve as an electronically signed document. Signed,
sealed hardcoples have been transmitted to the Product Approval
Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest
in any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest In any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Modified Bitumen Roof Systems
Compliance Statement: Polyglass SBS and APP Modified Bitumen Roof Systems, as produced by Polyglass USA,
Inc., have demonstrated compliance with the following sections of the 51h Edition (2014) Florida Building Code
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations / Conditions of Use set forth herein.
4
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind
FM 4474
2004
1504.3.1
Wind
UL 1897
2008
1504.7
Impact
FM 4470
1992
1507.11.2
Physical Properties
ASTM D6162
2000
1507.11.2
Physical Properties
ASTM D6163
2000
1507.11.2
Physical Properties
ASTM D6164
2005
1507.11.2
Physical Properties
ASTM D6222
2008
1507.11.2
Physical Properties
ASTM D6509
2009
3: REFERENCES:
gngiy
Examination
Reference
Date
ERD (TST6049)
Physical Properties
P10490.10.08-2,
10/30/2008
ERD (TST6049)
FM 4470/4474
P13760.09.09
09/10/2009
ERD (TST6049)
FM 4470/4474
P13770.09.09
09/10/2009
ERD (TST6049)
FM 4470/4474
P30540.11.09-R1
11/30/2009
ERD (TST6049)
FM 4470/4474
P30550.12.09
12/02/2009
ERD (TST6049)
Physical Properties
P33960.12.10
12/30/2010
ERD (TST6049)
FM 4470/4474
P33970.03.11
03/15/2011
ERD (TST6049)
Physical Properties
P37590.03.13-3A
03/06/2013
ERD (TST6049)
FM 4470/4474
P39680.03.13
03/04/2013
ERD (TST6049)
Physical Properties
P37590.03.13-1-R1
06/26/2013
ERD (TST6049)
Physical Properties
P37590.03.13-2-R1
07/01/2013
ERD (TST6049)
Physibal Properties
P37590.07.13-2
07/01/2013
ERD (TST6049)
Physical Properties
P37590.03.13-5-R1
07/01/2013
ERD (TST6049)
Physical Properties
P37590.07.13-1
07/02/2013
ERD (TST6049)
FM 4470/4474
P41630.08.13
08/06/2013
ERD (TST6049)
Physical Properties
P45940.09.13
09/04/2013
ERD (TST6049)
Physical Properties
P44370.10.13
10/04/2013
ERD (TST6049)
Physical Properties
P39520.09.14-2
09/11/2014
ERD (TST6049)
FM 4470/4474
SC6160.11.14
11/10/2014
ERD (TST6049)
Physical Properties
PLYG-P45440SC.03.15-1
03/31/2015
ERD (TST6049)
Physical Properties
SC5170.05.15
05/08/2015
ERD (TST6049)
FM 4474
SC8085.05.15
05/19/2015
ERD (TST6049)
Physical Properties .
SC5170.12.15
12/29/2015
ERD (TST6049)
FM 4470/4474
SC9455.15
04/01/2016
ERD (TST6049)
FM 4470/4474
PLYG-SC8905.05.16-1
05/17/2016
ERD (TST6049)
FM 4470/4474
PLYG-SC8905.05.16-2
05/17/2016
ERD (TST6049)
FM 4470/4474
PLYG-SC10815.07.16-RI
09/23/2016
ERD (TST6049)
UL1897
PLYG-SC12025.10.16
10/12/2016
ERD (TST6049)
FM 4470/4474
PLYG-SC11475.16
11/17/2016
ERD(TST6049)
FM 4470/4474/UL1897
PLYG-SC13235.01.17
01/17/2017
ERD (TST6049)
FM 4474/UL1897/TAS 114
PLYG-SC13920.05.17
05/30/2017
ERD(TST11294)
FM 4474/UL1897/TAS 114
PLYG-CTL13945.05.17-1
05/30/2017
Exterior Research and Design, I.I.C. Evaluation Report P9290.02.08-1119
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION FL1654-R21
Polyglass USA, Inc. Revision 19: 05/3012017
Page 2 of 6
an
4.
Entity
ERD (TST11294)
ERD(TST6049)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI(TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
Miami -Dade (CER1592)
Miami -Dade (CER1592)
UL LLC (QUA9625)
PRODUCT DESCRIPTION:
Examination
FM 4474/UL1897/TAS 114
FM 4474/UL1897
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
Physical Properties
Physical Properties
Physical Properties
Physical Properties
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
HVHZ Compliance.
Proposal for Review
Quality Control
Reference
PLYG-CTL13945.05.17-3
PLYG-SC13945.05.17
2W7A7.AM
OD3A3.AM
2DOAO.AM
2D5A9.AM
3006646
3001334
3001334
3000857
3004091
3006115
3012321
3014692
3014751
3007170
3019317
3020703
3018332
3023368
3024594
3023458
3030668
3032172
3049631
3057029
PUSA-062-02-01
PUSA-061-02-02
PUSA-064-02-02
PUSA-062-02-02
PUSA-188-02-01
PUSA-188-02-02
PUSA-188-02-03
PUSA-202-02-01
PUSA-202-02-02
Various NOAs
10-0823
Service Confirmation, R14571
TR 7tyIEftf7
Date
05/30/2017
05/30/2017
08/04/1994
04/04/1997
12/23/1998
06/22/1999
01/04/2000
01/25/2000
02/15/2000
01/12/2000
01/12/2000
05/02/2001
07/29/2002
08/05/2003
08/27/2003
01/13/2004
06/30/2004
07/30/2004
01/31/2006
03/20/2006
05/23/2006
07/18/2006
09/12/2007
06/12/2009
04/21/2014
02/02/2017
12/04/2007
01/28/2008
02/27/2008
12/04/2008
02/08/2017
02/08/2017
02/08/2017
05/17/2017
05/17/2017
Various
10/12/2010
Exp.10/06/2018
This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA,
Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass
membranes make up the subject systems.
�1s/ '� } L.4 �fi:f^*`�""�$ Ni .�'� t 'ry+:jy�j-(i�•`6�."wa�'n°•�';'.. „� vA'k tkk' "k�+,`.t.'KY.i$bn�' �. � 'TMS�'n.,.�..iGi``^.#i K"C"'"l 4� s` �.+�y'�'C "^.� 'q�{rc.#tai "�2if'�' �`"�o _i"�r
Y ,kEN yg Iu` T48LEv�1 sR"OLL GOODS+OR�POLYGLASSMODItEDfBI,TU1111ENR001.45YSTEMStr"
Type
Product
Specification
Reference
Grade
Type
Base Sheets
Polyglass G2 Base
ASTM D4601
N/A
II
Polyflex SA Base
ASTM D4601
N/A
II
Polyglass APP Base
ASTM D6509
N/A
N/A
Exterior Research and Design, U.C.
Certificate of Authorization #9503
FBC NON-HVHZ EVALUATION
Polyglass USA, Inc.
Evaluation Report P9290.02.08-R19
FL1654-R21
Revision 19: 05/30/2017
Page 3 of 6
TOR IN- 17Y�fRfl
CnOr�kTINU1,«.D)ROLLjGOODSFOR,s��YGIAS$`MOQIFl?5:��aNaNR�.Oc
Type
Product
Specification
Reference
Grade
Type
SBS Membranes
Polyglass HT Base 650
ASTM D6162
S
III
Elastobase
ASTM D6153
S
I
Elastoflex V
ASTM D6163
S
I
Elastoflex SA V Base
ASTM D6163, Table 2
S
I
Elastoflex SA V FR Base
ASTM D6163, Table 2
S
I
Elastoflex SA V Plus
ASTM D6163
S
I
Elastoflex SA V Plus FR
ASTM D6163
S
I
Elastobase Poly
ASTM D6164
S
I
Elastoflex S6
ASTM D6164
S
I
Elastoflex S6 Type II
ASTM D6164
S
II
Elastoflex VG
ASTM D6163
G
I
Elastoflex VG FR
ASTM D6163
G
I
SBS Membranes
Elastoflex S6 G
ASTM D6164
G
I
Elastoflex S6 G FR
ASTM D6164
G
I
Polyfresko G SBS (sand or poly -film backed)
ASTM D6164
G
I
Polyfresko G SBS FR (sand or poly -film backed)
ASTM D6164
G
I
Elastoshield TS G
ASTM D6164
G
I
Elastoshield TS G FR
ASTM D6164
G
I
Elastoflex SA P
ASTM D6164
G
I
Elastoflex SA P FR
ASTM D6164
G
I
Polyreflect
ASTM D6164
S
1
APP Membranes
Polyflex
ASTM D6222
S
I
Polyflex G
ASTM D6222
G
I
Polyflex G FR
ASTM D6222
G
I
Polyfresko G
ASTM D6222
G
I
Polyfresko G FR
ASTM D6222
G
I
Polybond
ASTM D6222
S
I
Polybond G
ASTM D6222
G
I
Polyflex SA P
ASTM D6222
G
I
Polyflex SA P FR
ASTM D6222
G
I
Polyfresko G SA
ASTM D6222
G
I
Polykool
ASTM D6222
S
I
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in anyway, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for
permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in HVHZ jurisdictions.
5.3 Refer to a current Roofing Materials Directory for fire ratings of this product.
5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance
with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 or 2603.6 apply.
5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural
members shall be in accordance with FBC requirements to the satisfaction of the Authority Having
Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC
Approval documentation.
5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1510.
Exterior Research and Design, LLC.
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION
Polyglass USA, Inc.
Evaluation Report P9290.02.08-1119
FL1654-R21
Revision 19. 05/30/2017
Page 4 of 6
TR1N1T_Y1 RD
5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure
for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to
resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data
Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3
enhancements.
5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected
assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No
rational analysis is permitted for these systems.
5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the
existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison
to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-
1 or Testing Application Standard TAS 105.
5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the
existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If
any surface conditions exist that bring system performance into question, field uplift testing in accordance
with ANSI/SPRI IA-1, ASTIVI E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS
124 shall be conducted on mock-ups of the proposed new roof assembly.
5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system
shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority
Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss
Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC
Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or RAS 111, except the basic wind
speed shall be determined 'from FBC Figure 1609.
5.13 All products in the roof assembly shall have. quality assurance audit in accordance with the FBC and F.A.C.
Rule 61G20-3.
6. INSTALLATION:
6.1 Polyglass Modified Bitumen roof systems shall be installed in accordance with Polyglass USA, Inc. published
installation instructions, subject to the Limitations / Conditions of Use noted herein.
6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects
the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been
applied). Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, U.C. Evaluation Report P9290.02.08-R39
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION F1.1654-1121
Polyglass USA, Inc. Revision 19: 05/30/2017
Page 5 of 0
` QTAiN11Y FkD.
• 6.3 Any of the following FBC Approved coatings may applied to the top roof membrane without adverse effect
' on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated
with coating usage.
➢ PG200 Non-Fibered Roof Coating;
➢ PG300 Fibered Roof Coating;
➢ PG600 Non-Fibered Aluminum Roof Coating;
➢ PG650 Fibered Aluminum Roof Coating;
➢ PG700 High Quality Elastomeric Roof Coating or KM Acryl 25;
➢ PG700QS (Quick -Set) High Quality Elastomeric Roof Coating or KM Acryl 25-QS (over granule -surfaced
APP or SBS only);
➢ PG800 Asphalt Emulsion Roof Coating;
➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating;
➢ Polyplus 65 Premium Fibered Aluminum Roof Coating;
➢ Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15;
➢ Polybrite 70QS (Quick -Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS (over granule -
surfaced APP or SBS only);
➢ Polybrite 90 High Solids Silicone Roof Coating;
➢ Polybrite 95 Silicone Roof Coating.
7. BUILDING PERMIT REQUIREMENTS:
i
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 OA requirements
9. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625; (314) 578-3406, k.chancellor@us.ul.com
i
- THE 56-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 139290.02.08-1119
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION F1.1654-1121
Polyglass USA, Inc. Revision 19: 05/30/2017,
Page 6 of 6