Loading...
HomeMy WebLinkAboutBLOWER DOOR TEST FORMz Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method RECEIVED AUG 0 3 2018 ST. Lucie County, Permitti Date: ����/�' Permit #: / 7 0,P 0 (� 2 —7 Contractor: Job Address: %✓o �� e i� �� G ,>c e Construction: ( New Construction — Complete ( ) Existing — After Addition House Infiltration Test Results SLC Climate Zone 2 CFM (50) / 00f_ Test Date: Volume = / ? ACH (50) = CFM (50) x 60 / Volume =_ Mec anical Ventilation required less than 5 ACH Passing results must be & ACH (50) or less (ass ( ) Fail FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 2 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or i or an g approved third party. A written report of the results of the test shall be signed b the aconducting(test and ) provided to the code official. Testing shall be performed at any time after creati n of all penetrations of the building thermal envelope. FBC, Residential Where the air infiltration rate of a dwelling unit is less than 5 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name: Pro Duct Services Address: 1915 Rio Vista dr., Fort Pierce, fl. I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate Zone 2. Signature: Printed Name: Michael Faurot License/Certification #: 5059122