HomeMy WebLinkAboutBUILDING PLAN5/8" thick light textured
stucco on typical concrete
block construction
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12
26 ga. 5v crimp metal roofing attached t0 plywood deck using #9 x 1.v
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
5/8" thick x 8"w cut
coral finished stucco bands
RIGH7 ELEVATION
SCALE: 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #x11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
stucco on typical concrete
block construction
LEFT ELEVATON
SCALE: 1/4" = 1'-0"
r
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhead Doors, Sliding Doors, windows & Skylights
Opening
Type
NOA/FL
NUMBER
Product
Model
#
Manufacturer
Glass
Attachment method
TEST ation
Date
Design Pressure
of Approved Tests
1.2.3
4
FLU 1i499 2
Single Hung
Series 185
Mi Windows
and doors
3/ L" diq. corner
3 Tapcons w/ mi7 I I/ " P�^,tT LSuck imto solid
from each corner and G o.c. the rea ter throug
filled CI7!J wall maintaining min 2.5" edge distance in strict adherence
to the product approval.
+ 60 psf
-
A
16-0330.02
Overhead
Garage Door
Model 824/811
9'-4' max. width
I4'-0" max height
DABeing
nsta M Buckto concrete 5capt cc wrt
1) 95 bar dart. using 3/8' x L' Hilti HLC Sleeve anchors at 8" a.c.
Loth 1.25' ilia. uu►she s with min. 4' edge distance. Install track to buck
(I) S,. x 15/8' full thread lag screws in each bracket maintaining
min. of IS edge distance - GC to strictig adhere to product approval
rovide IiIL' ushnut washer on roller shorts
10-9-21
+ 50.0/-60.0 psf
B
FLU 16614.1
Fiberglass
Desi h P o/
Smo3
Jeld-Wen
Elco 1/4" dia. tapcon with min 1.25" embedment at 3" max
from corners and 11.5" o.c. max. thereafter in head and Jambs.
+ 50,0 PSF
C
FLU 15332.2
Sliding Glass
Door
Series 420
MI tJllndOWS
and doors
L ia, x 3 peons w mir�. penetration at 4 max.
from each corner and I' o.c. all double row thereafter through
PT Buck into solid filled CMU wall maintaining min 2.5" edge distance
in strict adherence to the product approval.
+ 48.2 PSF
Product
NOA/FL
NUMBER
Model #
Manufacturer
Attachment Method
Expiration
Date
Design Pressure
of Approved Tests
Mullions
FLU 15353.8
CM-18531
vertical mullion
Mi Windows
and doors
For CMU use (2) 1/4" x 2 3/4" tapcons with min 1 1✓4" embedment
penetration into each Mull Clip. Attach mull to clip using (4) #10 x 1.25"
self tapping screws per clip as shown in product approval.
+ 118.9 PSF
_
Roof
FLU 11451.12
5V Crimp
Metal Roofin g
Gulf Coast Supply
and manufacturing
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4 side laps and L" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
s aced L o.c. at all laps and two stagggered rows 12" o.c. in field. Attach
deck to trusses using attachment detml on roof plan
- 108.5 PSF
Siding
Stucco on Block
Soffit
FLU 12198.3
Model T4 12" vented
Vinyl Soffit
Kaycan
Install using 2" x 2" battens at 6" o.c. screwed to soffit framing using
# 10.x dia.wood5screws rain es ankruss.nailInstall soffi3/8"dtiato baadttens using
+55.0/-35.0 PSF
Hurricane
Panels
FI# 15014.2
24 Gauge
Storm Panels
Global Protection
Products LLC
Install using 1/2" dia. solid set lead anchors with 1/4" dia.-20 x 1.5"
long SS screw head combo. with Neoprene washer at 12 1/2" o.c.
along the bottom and 13" o.c. at the top
+ 46.0 PSF
-
LI�have reviewed the above and
approved it
by my seal below. ( Architect or Engineer of Record
12
SLOPE -4
COVERED
PORCH
nterlor Non-Bedrin
11111101
12„
• O.H.
Finish Columns with
thick cut coral
finished stucco bands
11
wz11111 • • - .
e1 L.�Ir �' ^
%\ BEARING
:k x 8% cut
Shed stucco bands
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 4" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6 o.c. at all laps and two staggered rows 12 o.c. in field. Attach
deck to trusses using attachment detail on this sheet
12
4 1 SLOPE
12„
GRESS
H
COVERED
PORCH
.
L�L
2
door
5/8" thick light textured \ I
stucco on typical concrete 5/8" thick x 8"w cut
block construction coral finished stucco bands
REAR ELEVA710N
12
4 [SLOPE
SCALE: 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max Spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and C end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6 o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
Ll
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using 8d nails. Substrate
to be 19/32" COX Plywood nailed at 6" o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
I
�I �I
'�
■ ■NONNI�I
I�
Mwo
im
ICI
�I �IJI
I�
I I
I I
ICI
CGi�I,
FRON7 ELF-Vi4TION
ii - & S -r a (a2 7
ST. LUC.E COi,�-Ty EL II ^.LAIC DI3LCION
R-VIEWED FOR C N
REV1LNIl,T,D BY ,� r
DATE
PLAN AND PER T ST BE KEPI ON JOB
ORN0 LNSPECTION eVILL BE MADE.
truss bottom cord t I .
ALL MANUFACTURES LABLES SHOWING
U FACTORS AND SHGC COMPLIANCE
WITH FBC ENERGY CODE MUST
REMAIN ON ALL DOORS AND WINDOWS
I INml. iNSPFCTH,Ns ARE APPROVED
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
0• C. REQUIRED BY FIELD INSPECTCRS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
.e
ermesh OR
6"x6" #10/10 WWM on 6 mil V!squeen over
clean compacted termite treated fill
Partition
4QNCEAtED FASTENERS RESrONS181UTY OF THE NTS
ARE TOE
CONTRACTOR OF RECORD
TERMITE TREATMENT REQUiRED
Braden lt Braden
- ' •
Avenue
B E-mail: bradenaia8comcast.net
''
283
Stuart. FL 349% UAAC000032
nits
Wcgnne Building Corp.
THE MAJESTIC
Spanish Lakes
St. Lucie County Florida
SCALE: 1/4" = 1'-0"
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSiNG
OCCURS BETWEEN THE BUYER AND WY1\NE BUILDING CORP
AND WILL COi\1TINUE FOR ONE YEAR FROM THAT DATE
FERM1771NG INFORMATiON
(FORM 100)
Florida Building Code Residential: 5th Edition and
ASCE 1-10 for Wind Loading
Building Design is.. Enclosed Risk Category: iI Wind Velocity: 165 mph ultimate
Mean Roof Height: II'-C" Roof Pitch: 4.12
internal Pressure Co�i-cient: ±0.I8
Subjectability to damage from: Weathering: Negligible
Termites: Veru Heav4
Width of Roof End Zone: 3'-4" Wind Speed: 145
mph ultimate
Wind Exposure Classification: C
Adjustment factor for Exposure Height: 1.21 x 0.6
= 0.�26 ASD desiggn
Load Combination: ASCE 1-10 Section 2.4 DL+LL;
DL+0.6WL; 0.6DL+0.2L
Components t Cladding Wind Pressure (NET) Roof
Zone: I. +20.6/-32.6 psf
Roof
Zone: 2. +20.6/-510 psf
Roof
Zone: 3. +20.6/-84.0 psf
Components I Cladding Wall End Zone Width. 3'-4"
Components t Cladding Wind Pressure (NET) Wall Zone: 4. +35.8/-38.-1 psf
Wall Zone: S. +35.8/-4�.8 psf
Components t Cladding Wind Pressure (NET) on Garage Door:+32.0/-40.3psf
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided? Yes
Are Components an Cladding Details Provided? Yes
Minimum Soil Bearing Pressure:2,500 psi, Presumptive: X Bg Test: psi
This Building Shall Have the Following:
APPROVED SHUTTERS: X IMPACT GLASS: BOTH: NEITHER:
ROOF LIVE LOAD: 3_ psf ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: 45 psf FLOOR DEAD LOAD: 10 psf
JOB ADDRESS: 23 Montere
TO .12oPITCH
® = Roof Zone I
Walls Zone 4
® = Roof Zone 2
Walls Zone 5
END ZONE
® = Corner Zones
Roof Zone 3
Model: Date Drawn : Revisions Sheet Comm #
i-2�-11
,� D raise n by:
PORCH 1 • 11 l ��
RIGHT Checked by:
D.R.B. OF 5
fF:LCCR
PLAN
4" Recess top plate b"w x 3/8"d
<� C lP A C I i f= O 7 n= T A I I for steel support angle
Counter top - verify type
with contractor
TYPICAL NOTES: SCALE 1/4" = 1'-C"
See detai► on this s eet
N.T.S.
I.
Contractor to verify ALL notes and dimensions prior to
36" high bg
4" diameter
proceeding with work.
steels crash
Flange With
post. Floor
4 - 3/8"
Steel countertop support angle
Install 0 from eachInd and
Base cabinet
2.
Contractor to STRICTLY enforce ALL OSHA Requirements.
expansion bolts Into
one in center of counter.
see angle detail"t
3.
ALL Lumber to be used as Beam, Rafters, etc... to have
slab (3/8
50 ksi steel plate)
2" x 8" wood studs
a minimum 1,400 P.S.I. fiber stress.
0
1/2" drywall
at 1`" o.c.
4.
No dissimilar metals to touch.
2rs" 2!6"
r' x 8" PT wood plate
S.
ALL Concrete used for slabs shall be min. 2,500 PSI concrete.
r;'
ALL Concrete used for vertical filled cells, cont. tie beams etc.. to
°
shall be 3,000 P.S.I. concrete and/or 4,000 P.S_I. rout mix
g s/8
O �
2/'
KITCHEN ISLAND
FRAMING DETAIL
Drywall at ceilings shall be leveled and attached to bottom chord
4„
z
of trusses with screws per FBC R102.3.5.
2 j2"
Attach buck to block wall with
1/4" dia. Elco conc screws with min.
-1.
ALL wood in contact with concrete shall be pressure treated.
10
° A
1 1/4" penetration at 12" o.c. max
8
ALL wall dimensions are nominal and not finished wall or stud dimensions.
'2" E t �. P.
and 4" max from each corner thru
2" x 4" PT nuck
9. ALL plumbing fixtures to be low flow.
10. Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
11. Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements. ��„ r�"
12. Lowest finished floor to be set by Governing Building Department 6"
surveyor to set in field.
13. Separation between residence and garage shall be per FBC R302.6
14. Door between garage and residence shall be 1-3/4"t 20 min. rated door
w.H. = Water Heater
15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 pper FBC R302.9.1
16_ Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per FBC iR302.9.2
11. All exposed attic insulation materials installed on attic floors shall have a critical radlant
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
materials exposed on the underside of the roof deck or on the attic walls shall comply
with F.B.C. R316 - see permit info box of code edition
18. G psum board material shall conform to ASTM C36, C79, C-415, C51,4, C630, C931
C460, C1002, CIC,41,C11171, C1118, C1218, C1395, or C1396 and shall be installed
according to the following: (FBC R�102.3.0) Masonry Beam
Dr wall
y
Thickness
Location
Orientation
Framing
Member
Max. spacing
p g
of fasteners
Nail sizing options for
g p
installation of drywall into
Spacing
Maximum
wood framin members
Nails
Screws
2 x min. t ickness
Ceiling
Perpendicular
24"
1„
12"
13ga 1 3/80Rng with 19/44" head
0.098" diameter x 1 1/4" long
annular -ringed or 5d cooler nail
�2
OR
Walls
Either
16"
811
16"
0.080" dia. xx 1 5/8" long with
Direction
15/64" head
OR
Gypsum board nail 0.086" dia.
x 1 5/8" with 9/32" head.
Ceiling
Perpendicular
24"
1„
12"
13ga 1 5/8" bong with 19/64" head
OR
0.098" diameter x 1 3/8" long
annular -ringed or 12 cooler nail
8,
OR
0.092" dia. xx 1 7/8" long with
Walls
Either
16"
81,
16"
Direction
1/4 head
OR
Gypsum board nail 0.0915" dia.
x 1 1/8" with 19/64" head.
19. ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A131.1
20. Cement, fiber cement or glass mat g�psum backers in accordance with ASTM
C1288, C1325, OR C11718 and installeI.A.W. manufacturers recommendations shall
be used as backer for the wall the in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accomparirg smoke
developed index not to exceed 450 when tested in accordance with �ASTM E 8-4.
Insulation shall comply with F.B.C. R316-
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL .1111651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM 1)(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) 10d x 1 1/2" nails
( 24" o.c.) supporting Max.
1810lbs. uplift
12
4 F_
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
(shop drawings bg manufacturer)
Aluminum Drip --_y " \R-30 blown fiberglass
Edge t Fascia in bottom chord of trusses
1/2" drywall with smooth finish
2" x 6" Sub -Fascia Two rows of beam block filled with concrete
and (1) 95 bar cont. in each row. Substitute
Kaycan full o vent vingI soffit installed precast lintel filled with concrete and (1) 45
using 1/8" dia shank x 15" long gaiv. bar cont. for bottom row over openings
roofing nails with 3/8" dia. head per
product approval - see chart sheet #I 1/2" dr wall over I" x furringg
strips at 1(." o.c. with R4.1 PI -foil
insulation on typical 8" Block walls
5/8" thick light textured All drywall to be installed per FBC R102.3.1
stucco on typical concrete i and shall meet all pertaining ASTM codes.
block construction T11 Mortar to be Type "M" only proportioned per FBC R601.1
and Mortar Jonts shall comply with FBC R601.2.1.
Provide Our-O-Rock at all wet areas (ex. showers, tubs etc...)
#5 bar vert. w/
30" overlap Fill cell with concrete and
at each filled cell (I) #5 bar vert. (typical).
Max. spacing shall not exceed
Wood 48" unless otherwise noted
Base see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
6"x6" #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
Grade
= i 1111
-1�1I I1111
-IIII 1 IIII I i'- 14" x 14" Concrete footing
with (2) 45 bars Cont. and 45
T` _ F I C�4 L S E ` 710
10 N transverse bars at 48" o.c.
Scale : 1/2" = I'-C"
-.1
of wall
varies -
#8 Wood screws thru jamb into buck
at each hinge and 15" o.c. max and
D e t a l l at D OOr prior to door attachment
NTS
INSTALL VULKEM BLOCK SEALANT
ON ALL JAMB, HEADER, AND
SILL BLOCK PRIOR TO BUCK
INSTALLATION
Install windows thru buck into
block with 3/14" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at jambe and 20" o.c. max.
Exterior face at head and sill per product approval
of wall Buck to I" x 4" PT
Varies
P.T. Buck nailed to
block with case hardened nails
Detail a t Windows prior to window attachment
NTS
Install SGD thru buck into
block with 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product approval
I" x 6" P.T. Buck nailed to
block with case hardened nails
Head
prior to door attachment
fixed door
sliding door
Masonry Wall
Ni
. .....
Bottomy Track
Tgpical Flooring
Sill
Install SGD thru buck into
block with 3/16" tap -con with
S
l l d 1 n g
[Door
OOr
D t, a l l
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c.
max
thereafter at Jambs per product
approval
Jamb
,At Masonry Wall
NTS
window Schedule
Mark
Size
Rou h open.
Window Description
PRESSURE ZONE
I.
4'-53/8" x 4'-6 %8"
54 %,' x 54 ye'
Single Hung
ZONE 4
2.
6'-2V'x 5'-3 %8"
15" x 63 %4"
Single Hung
ZONE 4
3,
2'-2" x 3'-2%"
21i"'x 38%"
Single Hung
ZONE 4
4.
3'-I" x 5'-3%8"
38 x 43'/4"
Single Hung
ZONE 4
ALL Windows to be aluminum windows w/ tint
nd mullions per elevations.
ALL windows to withstand pressures In permit info box on sheet
,ALL windows in bathrooms to be tempered
All rough opening dimensions to be verified bg contractor
wi h manufacturer s specs prior to construction
Door Schedule
M
rk
Size
Rough Opening
Door Description
PRESSURE ZONE
9'-0" X 1'-O"
108" x 84"
Overhead Garage Door
ZONE 4
3'-O" X 6'-8"
41"I/4" x 83%"
Fiberglass Panel - Inswing
ZONE 4
6'-O" X 6'-8"
14" x 81 %s" or eam bottom
Sliding Glass Door
ZONE 4
2'-0" X 6'-8"
Solid Core - Wood - 6-Panel -Bi-Fold Finished 24" x 81
2'-6" X 6'-8"
Solid Core - Wood - 6-Panel
5'-0" X 6'-8"
Solid Core - Wood - 6-Panel - Bi-Fold
2'-8" x 6'-8" x 1 %4"
Solid Core Wood, Steel, or Masonite Door
2'-8" X C-8"
Solid Core - Wood - 6-Panel
2'-6" X 6'-8"
Solid Core - Wood - 6-Panel - Bi-Fold
ALL
box
GARAGE
WITHSTAND
All
wi
Exterior doors to withstand pressures stated in permit info
on sheet 4I
DOOR SPECIFIED iN PRODUCT APPROVAL FORM AND SHALL
THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #1
rough opening dimensions to be verified bg contractor
h manufacturers specs prior to construction
11
0
W
W
W
W
r_
W
9
A/C
I
N Meter and panel
on either side of
house field verify
service location
Verify attachment
hole location with GC
prior to fabrication
3/8" thick 6„
steel bracket
COUNTER TOP BRACKET DETAIL
°
35'-O"
8'-10%2" 12" 8'-10%2" 12"
T-i r2„
D
F) Ell C]OIL-
°
cam!
EGRESS
13'-II°
Filled der
girder
der above
POfi�C�-I
� �
o WIRE LATH t STUCCO
-
CEILING
O
3' 9"
MASTER
BEDROOM
El
VC
00
OO O
MT
O OO
rik 8'-0" A.F.F.
Flat Ceiling
I
�
I
C
Vanity to be
34 %2 „ high
Rod Shelf
_ 8'-O" to 9'-8" A.F.F.
_
i Vaulted Ceiling
Mirror a) 1 L
r- O 1
GREAT'ji
' O O M
CLOSET10
1
0
----
�
}--I Rod t Shelf
0
in
a -7
32" DRYER ASHER
LAUNDRY
---
y y
O
8'-0" to 9'-8"
Vaulted Ceiling
A.F.F.
O
0
4 oJ"�`�J
DINING
Vanity to be
Oi 34 �2 „ high
ROOM
18" -1 42„ 11
1 I
1
T counter tops to 3/8" thick steel
v overhang wall 1.5"
1
5'-3"
counter top supp
90
its
eq eq- coun
er toto
o
6 over
ang wall
0
- ]
°
PANTR D
s
-
n,_4„
- - i ---
.o I
CAB
m
U
o
IE
+41" high wall o I DW
�
SECONE-D
�
BEDROOM r 1
KITCHEN a
1 0
_ I
,_ „ ,- „
8 0 to 9 8 A.F.F._ I
8'-0" A.F.F.
Vaulted Ceiling ``� O
1
Flat Ceiling r 1
Upper cabinets to I -
�
F
extend over Ref.
1
1
1
MICRO1. JAVE=
REF. NON-Y NT
2' -8" �{„„
'I
cv 38" CLEAR
OPENING L
Oi4=i
I
�y
-
Provide auto R-11 Batts Insulation
R-ll Batts Insulation closer
_8„
G
4" 5'-O" 4"0 Steel Ballard
see detail on this
sheet
0
�� W j
-x-s4 -m
1 J
I � 22 �, „
> � O 1 Z Attic Access
= I light
>
I q with
1 d L__--_J
150 Amp 8'-O" A.F.F.
Panel Flat Ceiling
GARAGE
Block wall in
garage to be
struck block
13' O" \�
r
8'-0" AFF
Flat Ceiling C
G!4R14G 3 n OD
rn�
Block wall in i
EMT Q garage to be p
struck block CA
6' 4" 13'-0„
EMER ENCY
EGRESS F - - - - - - - - - - - - - ---�
I I I I
I I I I
I I I 1
I I I I
I I I I
I I I I
lE1E1 Ell IE ^E V HO TC DT D 100
2,-8„ 9,_0„ 2,_8„
35'-O"
Square Footage Breakdown
Total A/C Space = 1,608 sq. ft.
Covered Porch Total = 264 sq, ft.
Garage = 518 sq. ft.
Total Cubic Ft = 12,864 Under Roof Total = 2,sq. ft.
STRUCTURAL MOTES:
I.
ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
9.
SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2.
ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSi AT 28 DAYS
10•
DESIGN LOADS ARE AS FOLLOWS:
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
ROOF (DL+LL) = 471 PSF
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET 41
BE 3000 PSI OR 4,000 PSi GROUT MiX AT 28 DAYS
EXPOSURE ="C"
3.
POISON SOiL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
iI_
ALL REINFORCING STEEL SHALL BE GRADE LO, MEETING ASTM A-16, t
4
GROUND FLOOR SLAB TO BE A MiNiMUM 4" THICK W/ 6X6 10/10
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL,
WELDED WiRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
12
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FiLL
.
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
5.
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL iS BROUGHT iN. FILL TO BE SPREAD iN 12" LAYERS AND
MACHINE COMPACTED TO A MINIMUM OF 2500 PSI IN AREA OF
13.
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
BUILDING CONSTRUCTION
FOOTING: 3"
BEAMS: i-1/2"
6
TEST FOR FILL COMPACTION MINIMUMS PRIOR TO FORMING SLAB.
14.
LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
71-
GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
15.
USE STRUCTURAL GRADE WOOD WiTH A MINIMUM Fb OF 1600 PSI
ATTENTION OF THE ARCHITECT.
IL
ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
8-
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
FOUNDATION PLAN
17. ALL LUMBER IN CONTACT WiTH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
1. Any changes to plans must be Submitted to the architect
for approval before proceeding With construction.
2. Contractor Shall be responsible for verification of all
notation and dimensions before starting construction.
3. SOi1 conditions assumed to be 250Ci psf. Should any other conditions be
encountered, the architect Shall be notified in writing for revision
4. Verify all recess thickness at showers, tile, etc....
5. Contractor to provide filled cell with concrete and i #5 bar Vert. at 48"
o.c. max. provide (1) filled cell on each Side Of openings up to 5'-I1" wide.
provide (2) filled cells On each Side of o enin s from �'-O" to mil'-I1"
and provide (3) filled cells on each side of Openings from 10'-0" and Up
Contractor to see plans for any other condition used. Foundation Walls
Shall have filled cells at 2,4 o.c. unless otherwise noted ( see section)
�. Contractor to provide for Form Board Survey - Form Board Survey
to be provided to Truss Company prior to truss construction
1. Contractor to provide for soil test prior to construction and provide
a copy of soil test to architect for review prior to construction
8. ALL Reinforcing steel Shall be grade �0, meeting ASTM A-1� and
A-35 specifications. ALL Anchors to be A-301 steel.
9. Provide a minimum of 3 concrete protection at footings and
1-1/2 concrete protection at beams for ALL reinforcing bars.
G
U5 bar vert. w/
30" overlap —
at each filled cell
10��� �IiJ
=E TYPICAL
ECTIONS
4" concrete slab with fibermesh OR
6 x6 #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
.1.
....Ili
1*�14% x 14"d concrete monolithic
footing with (2) #5 bars cont.
I�
TYPICAL FOOTING DETAIL
J SCALE 1/2" = 1'-0"
4" concrete slab with fibermesh OR
6 x� 410/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
45 bar cont.
Step per
foundation plan
9'
10" (2) 45 bars cont. bottom steel
12"
2 DETAIL AT GARAGE STEPDOWN
12" x 12" concrete column
block filled with concrete
and (2) #i bars Vert. tied
into lintels above
Top of Tooter
14" below finished floor
pia 7
SCALE 1/2" = 1'-0"
Verify house slab
L��height in field
1III II IIIF
1-
30 x30 xl6 concrete
,III ' — column footling with (4)
lfl EFEFE, L111 45 bars each way
30"
COLUMN FOOTING DETAIL
SCALE 1/2" = 1'-0"
SCALE: 1/4" = 1'-0"
FOOTiNG
SCHEDULE
Mark
Size
Description
FI
14"W
x 14"D
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS
F
12"W
X 12"D
MONOLITHIC FOOTING
WITH (2) 45 BARS CONTINUOUS
8301,
x 30" x
COLUMN FOOTING WITH (4) #5 BARS EACH WAY
F4
8"W
x 8"D
THICKEN SLAB EDGE
WITH I #5 BAR CONTINUOUS
14"W
x 14"D
F5
With
Curb at Garage
MONOLITHIC FOOTING
WITH 2 45 BARS CONTINUOUS - CURB e' 0'-0"
Thicken edge to 8"x8"
with concrete and 4" concrete slab with fibermesh OR
one #5 bar continuous ("x6" 410/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
GRADE
ao CN I I I I I_
8°
PORCH SLAB EDGE DETAIL
SCALE 1/2" = 1'-0"
1*5 bar Vert. w/
30" overlap
at each filled cell
SEE TYPICAL
SECTIONS
Ad just curb heightrel,
based on gar. floor 4" concrete slab with fibermesh OR
slope. 6"xC #10/10 WWM on 10 mil Visqueen over
1*5 bar in curb clean compacted termite treated fill
0'-0 1=.F. OL
Grade
s.
_ 11DSEIIc
— i t III l i i 14% x 14"d concrete monolithic
footing with (2) #5 bars Cont.
14"
�j GARAGE CURB DETAIL
SCALE 1/2" = 1'-0"
2" x L" PT wood secured with \
3/8"dia. x L" anchor bolt at 18" o.c.
overhead door track secured to woad
jamb per manufacturer's product approval
Garage Door Jamb Detail
GARAGE DOOR TO WITHSTAND PRESSURES STATED N T S
iN PERMIT INFO BOX ON SHEET #I. SEE PRODUCT
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backf illing and compactlon Is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or f rdM d.
Treatment must be In accordance with the rules and laws
established by the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termlcide In annular space between sleeve and pipe.
Filled Cell Masonry Column With One
#5 From Footing To Tie Beam
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Single Filled Cell Column
NTS
Filled Cell Masonry Column With One
45 From Footing To Beam Each.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Double Filled Cell Column
NTS
Braden It Braden AIA, FA
Architects - Planners
411 S.E. Coconut Avenue
Tel : (112) 281-8258
Fax : (112) 281-8283
E-mail: bradenaias'comcast.net
Stuart, FL 349% UAAC000032
0
0
15'-3"
!A°J UA_Oil 1_1_1_1__J 1 _a_1_1_. IL°Jll°JII I
r---- FI —
I
I Fi
I
] 24„
FI I
8'-10 %2 12" 8'-10 %2" 12"
12" x 12" concrete column bl ck filled
with concrete and (2) 41 bars vert. tied
Into lintels above
0 � T
FfA�IddceL�lluroaider I
° gig�de�alaba�ge =_
Rear Porch Slab to p IL
be poured separately
f LiSI b
_J rom ouse a .
Thicken footing to
° 24"w x 14"d x 24"L
uo m
~N
under filled cell E a
O E) C
I under girder bearing. I ° N�p
I FI \ Rear Patio/Slab to FI 1
be flush with bottom of
sliding door recess. E.
Slope I"
I'
I
I
o II
C
I
of
H.B.
AiC
40)
4" cnncret_e- slah niit_h C)R
6"x6" 410/10 WWM on 6 mil Visqueen over
clean compacted termite t
II
I
—� DRYER ASHER
117 10 (7)
1
TERMITE TREATMENT REQUIRED
DI
�I
on
I
�II
I I
4" concrete slab with fibermesh OR
6 x6 3*10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
°I
L----- — — — — ——
r-- -----
bo 3.25" Step
4.75 Step
OOi DW
I
n
MICROWAVE i
REF. NON —VENT
38" CLEAR
OPENING F
o O H.B.
r ----� ----�
i— — — ; — — — —
co
W.H.
0
3.25" Step I
� _ I �# w
I I I� I
(L
� O
F5 O
Recess for
Garage Door
I
I
i 8
L——— — — — — ——
O O Recess for
arage oor
2'-8" q'-O"
I
1-1-1
It
�
o
IN
2'-8" I 61-411
I
F5
L— — — — — — — — — J
O O Recess for
Garage Door
2'-8" 9'-0" 2'-8,
Cl
0
0
0
0
ROOF SH- = ETiNG
ATTACH- IP NT" DPTAi
I. Minimum Nall Size = 8d ring shank (min. 2.8" long)
2. Minimum Screw Size = 48 x 2"
3. Minimum Sheathing Thickness 19/32" CDX PI wood
4. Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Ke
Area
Edge
Field
Fastener
Pressure
Zone I
6"
6"
8d ring shank
'48 psf
Zone 2
-4"
6"
8d ring shank
psf
Zone 3
�"
�{"
8d ring shank
84 psf
** Zone 3a
6"
6"
48 wood screw
112.5 psf
** Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Concrete
/ Lintel
Verify with Plan
Rebar 48 Bar Dia.
Min. Overlap
Provide #5 bars with min. 48 bar
diameters overlap into beam. Tie
filled cell steel into continuous
beam block steel
Provide 45 bar set in pre -cast
RCCF- FL 4 N
Scale : 1/2" = 1'-0"
lintel into beam where length of
the opening calls for it. - ® h 1 ' - O I � i h d h
Provide Cast -Crete
8U8-OB/OT precast
lintel set in mortar:
Min. 8" Bearing - - - - - - - - - - - -
12"x 12"
Column Block
Rebar
Column to Lirt&l /4ttachm&nt
NTS
SEAM SCHEDULE
Mark Size and Description
Two rows of beam block filled with concrete and 11*S bar
BI continuous in each row. Hook vert. bar over top bar with
48 90' bend bar with a 10" min. lap at top bar.
ver angs at un ass
— roof pitch at 4:12 unless
of erwlse note on this s eat
otherwise noted on this sheet
— Truss shop drawings to be
provided by manufacturer
— Any changes to this plan
shall be submitted to the
architect for approval in writing prior to starting constructiol
- ALL TRUSS TO TRUSS
CONNECTIONS BY
TRUSS MANUFACTURER
— Architect to review Truss
Shop Drawings fi rlor
_ to construction for layout
and Uplift verification
Poured Filled Cell - Contractor to provide for
Form Board Survey and to provic
Form Board Survey to Truss
Company prior to truss constru
Provide 45 bars with min. 48 bar
diameters overlap in filled cell. Tie
filled cell steel into continuous
I A:;, I I I C.f;464-- Z footer steel.
CBS WALL
' 4'1'
Poured Cor
concrete b
Scale: 1/2" = 1'-0"
SINGLE PLY REAR GIRDER TRUSS
Nail 2" x 4" blocking to Vert. leg of
truss with IOd x 1.5' nails at 4" o.c.
Install Simpson MGT into wall using
5/8" dia. threaded rod set min. 12"
into wet beam and (22) lod nails into truss
Poured Concrete
concrete block u
Concrete t
Manufacture
Anchors Per
rers Specs
'4" Max.
3� O C K 1 N C� DETAIL
Mush Mounted shutter Detail
)ER STRAPPING
TER BEARING POiNT
1/8" thick light textured stucco installed per
ASTM C 926 over ASTM D type 2 paper backed
wire lath nailed to substrate through one layer of
ASTM D Type 2 felt paper using 8d nails. Substrate
to be 19/32' CDX Plywood nailed at 6" o.c. in field
and edges with IOd ring shank nails into studs.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4' side laps and L" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6 o.c. at all laps and two staggered and
12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet \
Additional Precast Lintel " „ 7EI"S
#5 bars Lintel Bar Clear ,4 CLEAi2Length Length Span Bars
:..
2'-10" 2'-8" 1'-6" 2. 3
tt none
2'-2" 2,43 none
8F8-OB/IT 8F8-IB/IT 8F8-1B/2T
Additional 3'-10" 2'-8" 2,93 none
#5 bars = • ..
CLEAR;--" ::' 4'-6" 4'--4 3'-2" 2,#3 none
One Row of ' H" •�- :•;'
'. •" Block Above �: '
5'-4" 5'-2" 4'-0" 2,43 none
-10" 5'-8" 4' none
r : ,•; .( Precast Lintel r ,;;.!>�. .�
6'-4" 5'-4" 2,#4 none
Additional i
i.---- ,i #5 bars ' 7'-6" 1'-O" 6'-2" 2,#5 none
BFIL-IBAT 8FI4-1B/2T
NOTES:
8'-4" 1'-10" 1'-O" 2,45 none
I. min. coverage of steel=1.5"
2, min. bearing required m ea. end=8" ALL reinforcing steel is grade 60.
3- standard for reinf. steel=ASTM A415
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
LINTEL. SCHEDULE
Mark
Window
or Door
Unit
Width
Lintel
Size
Cast -Crete
Specification
Rows of
"H" Block
Above
ff
Bottom
tt m
Size
Steel
Size
Max.
Gravitg
Load
Max.
Uplift
Load
Max.
Lateral
Load
L22
2'-2"
3'-6"
8F8-OB/IT
I
as
3069
1549
1024
L31
2'-4.
X-8"
4'-0"
8F8-OB/IT
1
#5
2541
13L3
1L3
L45
4'-5"
5'-10"
8F8-OB/IT
1
#5
1105
909
339
L50
5'-0"
L'-V
8F8-OBAT
I
#5
1238
835
121
L60
L'-8"
�'-V
8F8-OBAT
I
45
1011
i2�
534
L80
8'-0"
9'-4"
8F8-IB/2T
1
#5
2
95
152
591
512
L90
9'-0"
10'-6"
8F8-IB/2T
1
45
2
#5
643
530
401
L90B
9'-0"
10'-4"
8FIL-IB/2T
ONE
1
#5
2
#5
1533
1183
401
LI00
10'-0"
iI'-4"
8F8-IB/2T
1
#5
2
#5
582
494
452
LIOOB
10'-0"
II'-4"
8FIL-IB/2T
ONE
1
#5
2
#5
1344
1028
452
L120
12'-0"
13'-4"
8F8-IB/2T
1
#5
2
##5
411
428
324
L120B
12'-0"
13'-4"
BFIL-IB/2T
ONE
1
#5
2
#5
10,15
1,10
324
LI40
14'-0"
15'-4"
8FI6-IB/2T
ONE
1
#5
2
us
1250
409
259
L160
14 -0"
il'-4"
8F8-IB/2T
I
#5
2
45
300
192
194
LILOB IL'-O" IT-4" 8FI6-IB/2T ONE I #5 2 nS 950 Boo 194
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSi CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED.
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) IOd x 1 1/2" nails
( 24" o.c.) supporting Max.
18101bs. uplift
Aluminum Drip �—
Edge t Fascia
12"
2" x 6" Sub -Fascia
Kagcan full o vent vingl soffit installed
using 1/8" dia shank x 15" long gals.
roofing nails with 3/8" dia. head per
product approval — see chart sheet #1
One row of beam block filled
with concrete and (1) 45 bar
coat. over 8" precast lintel —
filled with concrete and (1) 45
bar cont.
Aluminum Drip
Edge E Fascia
Flash and Counter
flash
Nail ledger to —
gable end truss
with (2) 10d nails
at each web
12
4�
9, _4„
1/2" thick stucco on 3/8" hi —rib lath
attached to horizontal and vertical wood
framing with nails or staples to provide
no less than 1-3/4" penetration into
horizontal wood framing and 3/4" penetr
into vertical wood framing members
5/8" thick light textured
stucco on typical concrete _
block construction �_
#5 bar vert. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be flush with bottom of
sliding door recess. Wood
Base
�� Step per foundation plan
Slope per foundation plan
;IIII; IIII; IIII; IIII;,,111111�111111��111111�1111111��11111���111111���11111��11111����1111���111111��� ���1—��1�1 ill 1111=
Aluminum Panel
Sizes per manufacturer
— See Typical Stud Detail
1/8" x 3/32" Wing Nut w/
appropriate washer and spacing
per manufacturer's Details
`m
.OG3"
N
v
.094,
q
E
m
m �m
I
Stud Detail
Stud w/ Die Cast Zinc "Ts
Nickel Plated Wing Nut
1/4'
nts
Brace Gable end
with 2" x 4" SYP #2
8ft back nailed to bottom
of top chords using (2) IOd
nails at each truss
PRE-ENGINEERED WOOD TRUSSES
» 24"o.c. TYPICAL
( shop drawings bg manufacturer )
R-30 blown fiberglass
in bottom chord of trusses
-1/2" drywall with smooth finish
Two rows of beam block filled with concrete
and (1) 45 bar Cont. in each row. Substitute
precast lintel filled with concrete and (1) 45
bar cont. for bottom row over openings
1/2" drywall over i" x furring
strips at IL" o.c. with R4.1 i-foil
insulation on typical 8" Block walls
All drywall to be installed per FBC R-102.3.1
and shall meet all pertaining ASTM codes.
Mortar to be Type "M" only proportioned per FBC R6071.1
and Mortar joints shall comply with FBC R601.2.1.
Provide Our-O-Rock at all wet areas (ex. showers, tubs etc
Fill cell with concrete and
(1) #5 bar vert. (typical).
Max. spacing shall not exceed
48" unless otherwise noted
see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
"x6" ##10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
s
14"
Topical Section at Front Forch
Scale 1/2" = I'-O"
Simpson HETA 20
Strap truss to wall
using Simpson MGT with
hurricane anchor at each
truss
5/8' dia. threaded
rod with min 12" embedment
( 2,4" o.c.) supporting
1810 lbs. uplift
A
Ma
HETA 20
into beam either wet set or in epoxy with
(22) 10d nails into truss. Add blocking to
truss lea Der detail on this sheet
L6
BI
LIO
B
L90B
.
B I
CL
o
Q
O
I
Qoo
J
M
0)
L90B
S
_
�e
_
..ti0
..,:•:w::
BI
W
Bi
L60
12„
DEW o
I
ink° �c4
ZZ //E�l
H
x4� en-6
�C- L ��
-Lta1m�{.-
d)
00
m 0 !o
-
B 1
L
*� = vcu'vZ
- --
Q u
�0)Or�- ,,
�,
I
cy
mix a�v
12
3 ° h
BI
SLO
W o
� ao � a,o�
19, �„
U
�
av�'��
E�
O �
w
�'' v
-I"
IS'-6"
E
X
to�rwa�
>ia��,�+,c
I
LLI
gI
k i
(�
e"
�m3E°1vE
L .
°� a
/Z
L22 BI
,
�`N�°�W
Q
E � w"'O
V ULT AREA L-
Q
a Q
�C,=
a ,�futo
Q�
tV
N
uj
O Q
a .._.
_
0o W
6
1%
E
in
12
pL
4 SLOPE
— I
VZ
W
D.H
j I B l
F-
W
= �I 22" x 54"
_
/
Attic Access
I I
with light
0D
8'-O" MAXI I 48
BI N I \
L31 V- 1 \ 1 12
/
I
1
I I SLOPE 'F
ODD SPACE
L22 BI
BI L22
w_
B I
(x
...)
BI
Q
o
U
BI
BI
81
L90B
L60
L90
CV
x
Simpson HETA 20 Provide for gutter
Provide downspout
hurricane anchor at each truss
( 24" o.c.) supporting Max.
1810 lbs. 'uplift
Y
w
Y
Y
J
y,
Provide downspout
PANEL
„A„
Poles
BR
Load
Wire
Description
circ#
circ#
Description
Wire
Load
BR
Poles
2
40
1.0 kw
#8
A/C comp
1
2
AHU
#10
3.5 kw
30
2
3
4
2
30
4.5 kw
#10
40 gal. water HTR
5
6
Range
#G
12.0 kw
50
2
1
g
1
20
1.8 kw
#12
Pump
9
10
Dryer
#10
5.0 kw
30
2
II
12
1
20
1.5 kw
#12
13
14
Dishwasher
#12
1.2 kw
20
1
1
20
1.5 kw
#12
Microwave
15
1L
Refrigerator
#12
1.2 kw
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
11
Ig
Recepts
#12
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
19
20
Recepts
#12
20
1
1
20
1.2 kw
#12
Clothes Washer
21
22
Recepts
#12
20
1
I
20
0.81 kw
#12
Garage Door Opener
23
24
1 Recepts
#12
20
I
1
20
1.4 kw
#12
25
26
Recepts
#12
1
20
1
1
20
1.92 kw
#12
21
28
Recepts
#12
20
1
1
15
#14
General Lighting
29
30
Recepta
#12
20
1
I
15
#14
General Lighting
31
32
Recepts
#12
20
1
1
15
#14
General Lighting
33
34
Exterior GPCI
#12
20
1
1
15
#14
General Lighting
35
36
Bathroom GPI
#12
20
1
1
20
#12
Smoke Detectors
31
38
General Lighting
#14
15
I
1
20
#12
Bathroom GPI
39
40
General Lighting
#14
15
I
spare
41
42
S are
PANEL "A" LOAD CALCULATION SHEET
Load Description
Qt .
Watts
Total(Watts)
General Lighting (3_ .watts sq. ft.)
Small. _,4.ppliance..C.ircult(s)
. Range.........................................................
Refrigerator ................... I ..............................
Microwave
.................................................................
Dish Washer
.................................................................
Clothes Washer
.................................................................
.Clothes..Drger................................................
Water Heater
.................................................................
Water Pump ...................................................
Garage. Poor.. Op�qne.r ......... ..............................
1135
3
5,205
2
1,500
3,000
I
12,000
1,200
1,500
12,000
1
1,200
1
1,500
1
1,200
1,200
I
11200
1,200
1
5.000
5,000
I
4,500
4,500
1
1,800
1,800
1
8i0
810
Total Watts
31,415
First 10000 Watts 9100%
1
10,000
10,000
Remainder 21,415 940%
1
O
10,966
Electric Heat or A/C 10,000 a65%
1
10,000
10,000
Calculated Load
Watts
30,%4
Voltage
240
Calculated Wattage Divided bg Voltage = Total Amps 129.03
Panel Size Required = 150 Amps
Electrical SUMbol Leg&_nd
S
Single Pole Switch
®
Recessed Can Light
53
Double Pole Switch
®
Egeball Recessed
PB
Push Button Switch
SS
Exhaust Fan
Duplex Outlet
Ceiling Mounted Light
Special Receptacle
0-
Wall Mounted Light
Light with Pull Chain (attic)
W i
Waterproof, ground fault interrupts
n
®
Floor Duplex Outlet
@
Computer Connection Jack
cM I
Carbon Monoxide Detector
1:J
Flood Light
UT
Thermostat
m
Electrical Panel
©
Central Vac
g
Electrical Meter
QS
Smoke Detector
Ceiling fan
®
Television Jack
®
Telephone Jack
AC c
A/C Disconnect
I x 4 Florescent Light
®
2 x 4 Florescent Light
sPicR
Speaker Hook -Up
I❑
Intercom
= JUNCTION BOX TO SUPPORT A FAN
O = THERMOSTAT LOCATION
B/A = Balanced Air
Electric Notes:
I. Use copper wire only, no aluminum.
2. Provide and wire all required smoke detectors.
3. Contractor to verify location of electrical
service and provider.
4. ALL paddle fans shall be on a rheostat.
5. ALL bath and kitchen receptacles to be GFi protected.
L. ALL exterior outlets to be WP/GFI protected.
1. Recessed cans to be installed per NFPA requirements.
8. AFCI receptacles are required in all rooms except
Kitchen, Bathrooms, and Garage.
9. A/C Return Air Balance Must comply w/ FBC RMW2
10. A/C Refriggerant lines that are run thru slabs must be
sleeved in FVC
11. ALL A/C Equipment shall comply with energy calculation
12. All work shall be performed bg a licensed electrical
contractor, the completed system shall be fullu operative.
13. Contractor shall pay for all fees, permits, tes-ting, and
inspections including blower testing where required.
14. All work shall be coordinated with other trades to avoid
interference with the progress of construction.
15. All required insurance shall be provided for protection
against the public liability and property damage for the
duration of the work.
16. Contractor shall guarantee all materials and workmanship
free of defects for a period of not less than two years from
the date of acceptance or certificate of occupancy, or one
year from closing sale of house.
Correction of defects shall be completed without additional
charge and shall include replacements or repair of any
other phase of installation that may have been damaged.
11. It is not the intent of these plans to show every minor detail
of construction. The contractor shall furnish and install
all items for a complete electrical system and provide all
the requirements necessary for the equipment to be placed in
proper working order.
18. All work shall be done in accordance with the N.E.C. and
shall comply with all local codes and ordinances, and shall
meet all standard requirements of the local electric utility
and telephone company.
42/0 Aluminum feed
I ''/2" Conduit
2" PVC ( FPL
2" rigid service FPL
SEE MAi
"J" and E
Calculatior
for Unit ii
A/C disc.
150
AMP
MCB
PANEL
A
Bare #L copper wire
to #5 cont. rebar in slab
=L_=CTi�iCAL_ MIS=fi
- Contractor shall use AL-CU Landing lugs. NTS
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
19. The electrical system shall be completely and effectively
grounded as required by the latest edition of the N.E.C.
20. All material shall be new and shall bear underwriters'
labels where applicable.
21. All equipment and panel sizes shall be verified before
ordering. The contractor shall provide circuit routings to
suit the job conditions.
22. Furnish and install all fixtures as called for on the plans
or as selected bg others.
23. All raceways and pipes placed in or through any concrete
slab shall be spaced a minimum of three diameters of the
largest conduit or pipe from any other service.
24. All exposed wire below 9'-1" shall be installed in metal EMT
conduit.
25. Dryer Vents to be installed per FBC RM1502
MECHANICAL LAYOUT
Q= THERMOSTAT LOCATION SCALE: 1 / , " = I' - O "
t
Braden AIIAI
j7Braden
Tel
:
_
. ,. - ..'5 COMCdSt.
Stuart, FL
314994 #AAC0000
N
Install oulet
under disc.
not shown for
clarity
ELECTRIC/4L
PLAN
' I
.I. Nolo,:.
Post Light with
Photo cell
Center Post Light
between drivewaus
"Z;
Cto
03 o
a�
x
oW
vZn
V�
vw
E>
0
LL
E
R
Wire For
Front Post
Light
WP GFCI