HomeMy WebLinkAboutENERGY EFFIENCY CODEFORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE MAJESTIC
Builder Name:
Street: THE MAJESTIC 3��(\`�
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: WYNNE DEV.
Jurisdiction:
Design Location: FL, Fort Pierce
County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1512.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1128.00 ft2
b. Frame - Wood, Exterior
R=11.0 384.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (1608.0 sqft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1608.00 ft2
6. Conditioned floor area above grade (ft2) 1608
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(141.9 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
a. U-Factor: Sgl, U=0.54 101.94 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.254 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1608.0 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1608.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.088 Total Proposed Modified Loads: 48.71
PASS.
Total Baseline Loads: 50.21
I hereby certify that the plans and specifications covered by
Review of the plans and
�'ff4E S7AT
this calculation are in compliance with the Florida Energy
specifications covered by this
�y0-
Code.
calculation indicates compliance
with the Florida Energy Code.
rnu''�. •y;`:-;•;.•.�, Oi~
PREPARED BY:
DATE: ZA 1244a
Before construction is completed
this building will be inspected for
compliance with Section 553.908
r
0 a y
R
I
I hereby certify that this building, as designed, is in compliance
Florida Statutes.,
6�
C0D
with the Florida Energy Code.
WE'D
OWNER/ F
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2. Flle �' ®p�i1
- Compliance requires a roof absorptance test in accordance with R405.7.2
4/3/2017 5:32 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
Title: WYNNE THE MAJESTIC
Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1608
Lot #
Owner: WYNNE DEV.
Total Stories: 1
Block/SubDivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name:
Rotate Angle: 225
Street:
THE MAJESTIC
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
ST. LUCIE COUNTY
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location TMY Site
Zone 97.5 %
2.5 %,
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2 39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
1 Entire House 1608
12864
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 MASTER BEDROO 238
1904 No
0
1
1
Yes
Yes
Yes
2 WIC 63
504 No
0
1
No
Yes
Yes
3 MASTER BATH 56
448 No
0
1
Yes
Yes
Yes
4 M.BATH 61
488 No
0
1
Yes
Yes
Yes
5 LAUDRY 36
288 No
0
1
No
Yes
Yes
6 BEDROOM 2 180
1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREAT R 589
4712 No
0
1
Yes
Yes
Yes
8 KITCHEN 228
1824 Yes
0
1
Yes
Yes
Yes
9 BATH 2 50
400 No
0
1
Yes
Yes
Yes
10 HALL 25
200 No
0
1
No
Yes
Yes
11 FOYER 82
656 No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio MASTER BEDRO 38 ft 0
238 ft2
----
0 1
0
2 Slab -On -Grade Edge Insulatio WIC
1 ft 0
63 ft2
---_
0 1
0
3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0
56 ft2
____
0 1
0
4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0
61 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0
36 ft2
___-
0 1
0
6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0
180 ft2
____
0 1
0
4/3/2017 5:32 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft
0
589 ft2
----
0
1
0
r
8 Slab -On -Grade Edge Insulatio KITCHEN 12 ft
0
228 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio BATH 2 5 ft
0
50 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio HALL 1 ft
0
25 ft2
----
0
1
0
11Slab-On-Grade Edge Insulatio FOYER 9 ft
0
82 ft2
----
0
1
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
#
Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1
Hip Metal 1695 ft2
0 ft2
Light
0.6
Yes 0.9
No
0
18.4
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1608 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) MASTER BEDRO
30
Blown
238 ft2
0.1
Wood
2
Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3
Under Attic (Vented) MASTER BATH
30
Blown
56 ft2
0.1
Wood
4
Under Attic (Vented) M. BATH
30
Blown
61 ft2
0.1
Wood
5
Under Attic (Vented) LAUDRY
30
Blown
36 ft2
0.1
Wood
6
Under Attic (Vented) BEDROOM 2
30
Blown
180 ft2
0.1
Wood
7
Under Attic (Vented) DINING/GREAT
30
Blown
589 ft2
0.1
Wood
8
Under Attic (Vented) KITCHEN
30
Blown
228 ft2
0.1
Wood
9
Under Attic (Vented) BATH 2
30
Blown
50 ft2
0.1
Wood
10
Under Attic (Vented) HALL
30
Blown
25 ft2
0.1
Wood
11
Under Attic (Vented) FOYER
30
Blown'
82 ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing
Solar
Belo w
1
NE=>W
Exterior Concrete Block - Ext InEMWSTER BE
_Va
4.1 17
0 8
0
136.0 ft2
0
0
0.6
0
2
SW=>E
Exterior Concrete Block - Ext InsMASTER BE
4.1 7
0 8
0
56.0 ft2
0
0
0.6
0
3
NW=>S
Exterior Concrete Block - Ext InEMASTER BE
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
_ 4
NE=>W
Exterior Concrete Block - Ext InddASTER BA
4.1 8
0 8
0
64.0 ft2
0
0
0.6
0
5
NE=>W
Exterior Concrete Block - Ext InsuM. BATH
4.1 7
0 8
0
56.0 ft2
0
0
0.6
0
6
NE=>W
Exterior Concrete Block - Ext InfiffDROOM 2
4.1 12
0 8
0
96.0 ft2
0
0
0.6
0
7
SW=>E
Exterior Concrete Block - Ext InEEMNING/GRE
4.1 30
0 8
0
240.0 ft2
0
0
0.6
0
8
NW=>S
Exterior Concrete Block - Ext InQINING/GRE
4.1 20
0 8
0
160.0 ft2
0
0
0.6
0
4/3/2017 5:32 PM EnergyGauge@) USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
WALLS
Adjacent Cavity Width Height
Sheathing Framing Solar
Belo
Space
w
9
SW=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 12 0 8
0 96.0 ft2
0
0 0.6
0
10
NE=>W Exterior Concrete Block - Ext Insul BATH 2 4.1 5 0 8
0 40.0 ft2
0
0 0.6
0
11
SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8
0 64.0 ft2
0
0 0.6
0
12
SW=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8
0 8.0 ft2
0
0 0.6
0
_ 13
N=>SW Exterior Frame - Wood MASTER BE 11 26 8
208.0 ft2
0:23 0.6
0
14
E=>NW Exterior Frame - Wood MASTER BE 11 11 8
88.0 ft2
0.23 0.6
0
15
W=>SE Exterior Frame - Wood MASTER BE 11 11 8
88.0 ft2
0.23 0.6
0
DOORS
# Ornt Door Type Space Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>N Insulated FOYER None
.39 3
3
6 8 21.7 ft2
WINDOWS
Orientation shown is the entered orientation => chan ed to Worst Case.
V
Wall
Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC
Area Depth
Separation
Int Shade
Screening
1 NW=>S 3 Metal Low-E Single Yes 0.54 0.25
32.9 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2 NE=>W 5 Metal Low-E Single Yes 0.54 0.25
6.9 ft2 1 ft 0 in
1 ft 4 in
None
None
3 NE=>W 6 Metal Low-E Single Yes 0.54 0.25
16.4 ft2 1 ft 0 in
1 ft 4 in
None
None
4 SW=>E 7 Metal Low-E Single Yes 0.54 0.25
20.6 ft2 1 ft 0 in
1 ft 4 in
None
None
5 SW=>E 7 Metal Low-E Single Yes 0.54 0.25
25.1 ft2 1 ft 0 in
1 ft 4 in
None
None
6 NW=>S 8 Metal Low-E Single Yes 0.55 0.25
40.0 ft2 9 ft 0 in
1 ft 4 in
None
None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 1040 ft2 1040 ft2 48 ft
8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356 1500.8 82.39 154.95 .2598
7
HEATING SYSTEM
# System Type Subtype Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump Split HSPF:8.5
34.8 kBtu/hr
1
sys#1
4/3/2017 5:32 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 /
FORM R405-2014
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit
Split
SEER: 15 34.8 kBtu/hr cfm
0.8
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1
Electric
None
Garage
0.97 40 gal .60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert
# Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
/
-- Supply —
-- Return —
Air
CFM 25 CFM25
HVAC #
v #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool,
1
Attic
6 325 ft2
Attic
95 ft2 Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Heating
Jan Feb
[X] Mar
[ ]
[ ]Ape
[ ]
i rl Jun rl Jul
[ ]
rl Aug
Sep - �j
�Xj
0
Occt
t
H Nov
Nov
H Dec
Dec
Venting
Jan Feb
X Mar
[X] [
L
May [ Jun [ ] Jul
[ j Aug
Sep
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling (WD)
AM
78
78 78
78 78 78
78
78 80
80
80
80
PM
80
80 78
78 78 78
78
78 78
78
78
78
Cooling (WEH)
AM
78
78 78
78 78 78
78
78 78
78
78
78
PM
78
78 78
78 78 78
78
78 78
78
78
78
Heating (WD)
AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
Heating (WEH)
AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
4/3/2017 5:32 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 /
'FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE MAJESTIC Builder Name:
Street: THE MAJESTIC Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: WYNNE DEV. Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
-The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
4/3/2017 5:32 PM EnergyGauge@) USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows"
Description
a. U-Factor:
Sgl, U=0.54
SHGC:
SHGC=0.25
b. U-Factor:
Sgl, U=0.55
SHGC:
SHGC=0.25
c. U-Factor:
N/A
SHGC:
d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth
Area Weighted Average SHGC:
THE MAJESTIC, FT. PIERCE; FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1128.00 ft2
b. Frame - Wood, Exterior
R=11.0
384.00 ft2
1
c. N/A
R=
ft2
2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1608.00 ft2
1608
b. N/A
R=
ft2
c. N/A
R=
ft2
Area
11. Ducts
R ft2
101.94 ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
40.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
34.8 SEER:15.00
ft2
3.254 ft.
0.250
8. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1608.00 ft2
b. N/A R= ft2
c. N/A R ft2
13. Heating systems
a. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code.compliant features.
Builder Signature: Date:
Address of New Home: �) �� �� City/FL Zip
2W -
kBtu/hr Efficiency
34.8 HSPF:8.50
Cap: 40 gallons
EF: 0.97
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/3/2017 5:32 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
o�
a