Loading...
HomeMy WebLinkAboutNOTICE OF PRODUCT CERTIFICATIONNOTICI W PRODUCT CERTIFI MON CERTIFICATION' NO: DATE: CERTIFICATION PROGRAM: COMPANY: CODE: REVISION DATE: NI009467-R4 05/19/2007 Structural Nan Ya 661-1 03/05/2015 To verify that the "Notice of Product Certification"is valid, please visit www.NAMICertif cation.com to assure that the product is active and currently listed: This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document COMPANY NAME AND .ADDRESS PRODUCT DESCRIPTION Nan Ya Plastics Corporation USA "Fiberglass Gliding French Patio Doors" 8989 North Loop East, Suite 800 w/Reinforced Sidelites Houston, TX 77029 Fiberglass Sliding Glass Door Configuration: OXXO Glazing: IG-1/8" Tempered Glass/ Laminate-1/8" Annealed Glass/0:090" PVBby Solutia/ 1/8" Annealed Glass Frame: W-3585mm(141.13") H-2426mm(95.5") Panel: W-908mm(35.75") H-2346mm(92.38") SPECIFICATION PRODUCT RATING ANSI/AAMA/NWWDA 101/I.S.2-97 SGD-R50 TAS 201/202/203-94 Design Pressure: ±2400 Pa (50 psf) ASTM E1886-02/E1.996-02 Large Missile Impact Rated ASTM E1304-02 Wind Zone 4-Missile Level D FER-Passed Product Tested By: Certified Testing Laboratories Report No: CTLA-1602W/CTLA-1602W-1/CTLA-1.602W-2 A. Expiration Date: February 28, 2021 =' -lip Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 95 r FE HE 141 Ilb MAX VKAML WIUIH 25" 35 3/4" MAX D.L.O. PANEL WIDTH 79" D.L.O. 92 3/8" MAX PANEL HEIGHT 1/2" UFIXED IAX AME FIXED ACTIVE ACTIVE IGHT SERIES SPLS GLIDING PATIO DOUBLE DOOR W/ SIDELITES EXTERIOR VIEW DESIGN PRESSURE RATING IMPACT RATING ±50PSF LARGE AND SMALL MISSILE IMPACT MISSILE LEVEL D,'WIND ZONE 4 AND HVHZ REVISIONS DESCRIPTION DATE I APPROVED REVISED DIMENSIONS 02/18/15 1 R.L. NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 4. UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEET 2 FOR GLASS DETAILS. 5. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS.. 6. FRAME JAMB AND HEAD MATERIAL: CO=EXTRUDED PVC FOAM 1 1/2" THICK. 7. FRAME SILL MATERIAL: CO —EXTRUDED PVC FOAM 2" THICK WITH ALUMINUM CLADDING .063" THICK. 8. DOOR PANEL AND SIDELITE MATERIAL: PVC FOAM TOP AND BOTTOM RAILS, AND PVC FOAM VERTICAL STILES WITH PINE REINFORCEMENTS AND POLYURETHANE FOAM CORE. 9. APPROVED CONFIGURATIONS: OX, XO, AND OXXO. SEE SHEET 2. 7 ,1 TyTABLE OF CONTENTS SHEET NO. DESCRIPTION 1 OXXO ELEVATION AND NOTES 2 ADDITIONAL CONFIGURATIONS ANCHOR LAYOUTS & HARDWARE zzmtb,! 3 — 5 INSTALLATION DETAILS NAN YA PLASTICS CORP. USA 8989 NORTH LOOP EAST HOUSTON, TX 77029 FIBERGLASS GLIDING PATIO DOOR W/ REINFORCED SIDELITES OXXO ELEVATION AND NOTES DRAWN: DWG N0. REV A.P. 08-01664 A SCALE NTS IDATE 07/03/12 1 SHEET OF 5 SIGNED: 0211912015 LL/0 �1///�i E * 051 -. T((AATT*E OF 0�. ZOR\Okip '�'�F•'cP • \�a`�. ///�jpjS•��NA 11E�C?��\ D c 71 7/8' 1- 71 7/8" 6 FIXED 4CTIVE SINGLE W/SIDELITE EXTERIOR VIEW FIXED 4CTIVE SINGLE W/SIDELITE EXTERIOR VIEW MULTI POINT LOCK SET LOCK KEEPER ASTRAGAL STRIP ASTRAGAL DETAIL EXTERIOR INTERIOR REVISIONS REV DESCRIPTION GATE APPROVED A REVISED DIMENSIONS 02/18/15 R.L. EXTERIOR INTERLOCK STRIP WEATHER STRIP WEATHER STRIP INTERLOCK STRIP COVER e INTERIOR MEETING RAIL DETAIL 5 3/4" El DOOR SILL A. MULTI POINT LOCKING SYSTEM B. (1) DIE CAST HANDLE SET PER ACTIVE PANEL C. (2) STAINLESS STEEL TANDEM ROLLERS PER PANEL D. PVC ASTRAGAL BY NAN YA PLASTICS 1" 1/8" ANN 090" PVB BY SOLUTIA --{I 1/8" ANN 1/8" TEMP r ALUMINUM 5/8" BITE SPACER SYSTEM } INTERIOR EXTERIOR SILICONE GLAZING DETAIL BEDDING SIGNED: 0211912015 NAN YA PLASTICS CORP. USA \\\\S lR I !Lf07j/�i� 8989 NORTH LOOPEAST HOUSTON, TX77 29 FIBERGLASS GLIDING PATIO DOOR*�•/� 0y,.�6}�51//��'' W/ REINFORCED SIDELITES a (iEK„l6st[;z�' ADDITIONAL CONFIGURATIONS AND HARDWARE �- STATEE ( 4� ORA'NN: DWG N0. 08 REv A %O��s'�CORID. G /�/7S,r7NA11E?\\\\ SOE664 SCALE DATE NTS 07/03/12 2 OF 5 95 7" 16" MAX MAX 'I MAX 4" MAX 12 MAX L 16" MAX O.C. } 1/2" i 4" MAX ANCHORING LAYOUT FOR DOUBLE W/SIDELITES EXTERIOR VIEW ANCHORING NOTES: 1. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 2. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 3. FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 5'/8" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD - MINIMUM. SPECIFIC GRAVITY OF G=0.42 B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). - 7 MAX DESCRIPTION REVISED DIMENSIONS REVISIONS DATE I APPROVED 02/18/15 1 R.L. .� 16" 7" _ 1 4" MAX 12 MAX O.C. ` 16" 1 ANCHORING LAYOUT FOR SINGLE W/SIDELITE EXTERIOR VIEW NAN YA PLASTICS CORP. USA 8989 NORTH LOOP EAST HOUSTON, TX 77029 FIBERGLASS GLIDING PATIO DOOR W/ REINFORCED SIDELITES ADDITIONAL CONFIGURATION AND HADWARE A.P. I 08-01664 SCALE NTS — 07/03/12 1 SHEET OF 5 1 4" MAX SIGNED: 0211912015 WOOD FRAMING BY OTHERS FLANGE TO BE SET IN A BED OF APPROVED SEALANT WON EXTERIOR `j F-1 I r II •: II I '�'�'a SILL TO BE SET IN BED OF APPROVED SEALANT WOOD FRAMING BY OTHERS EDGE DISTANCE 1 3/8" MIN EMBEDMENT 1 /4" MAX. SHIM #10 WOOD SCREW REVISIONS REV DESCRIPTION DATE APPROVED A I REVISED DIMENSIONS 1 02/18/15 1 R.L. 1 3/8" MIN �� _J 1 /4" MAX EMBEDMENT I I SHIM SPACE 1/2" MIN. EDGE DISTANCE \ INTERIOR WOOD FRAMING BY OTHERS GUVC UIJ IMIVVC VERTICAL CROSS SECTION DOOR SHOWN, SIDELITE SIMILAR 2X BUCK/WOOD FRAMING INSTALLATION FLANGE TO BE SET IN A BED OF APPROVED SEALANT — # 10 WOOD SCREW INTERIOR EXTERIOR BACKER ROD AND APPROVED SEALANT BY OTHERS HORIZONTAL CROSS SECTION 2X BUCWWOOD FRAMING INSTALLATION MIN NAN YA PLASTICS CORP. USA BENT 8989 NORTH LOOP EAST HOUSTON, TX 77029 FIBERGLASS GLIDING PATIO DOOR W/ REINFORCED SIDELITES INSTALLATION DETAILS DRAWN: DWG NO. A.P. 08-01664 SCALE NTS I DATE 07/03/12 ;EET4 OF 5 SIGNED: 0211912015 ,R I IL/D,//// =*• 5 st�COyC�••*= STATE OF NA `I�?G`�� FLANGE TO BE SET IN BED OF APPROVED SEALANT 1X BUCK BY OTHERS, 1X BUCK TO BE PROPERLY SECURED 2 5/8" MIN. EDGE DIST. a A if a MASONRY/CONCRETE BY OTHERS MIN. EMBEDMENT 1 /4" MAX. SHIM 3/16" TAPCON EXTERIOR I `I rl l r INTERIOR SILL TO BE SET IN BED OF APPROVED SEALANT MASONRY/CONCRETE BY OTHERS 2 5/8" MIN. EDGE DIST. -" VERTICAL CROSS SECTION MASONRY/CONCRETE INSTALLATION DOOR SHOWN SIDELITE SIMILAR 1 3/8" MIN EMBEDMENT 1X BUCK BY OTHERS, 1X BUCK TO BE PROPERLY SECURED WOOD FRAMING BY OTHERS 2 5/8" �. MIN EDGE DISTANCE a FLANGED TO SET J IN A BED OF APPROVED SEALANT. 16" TAPCON REVISIONS REV DESCRIPTION DATE I APPROVED A I REVISED DIMENSIONS 02/18/15 1 R.L. 1/4" MAX SHIM SPACE -- 3/16" TAPCON INTERIOR BACKER ROD AND APPROVED SEALANT BY OTHERS HORIZONTAL CROSS SECTION MASONRY/CONCRETE INSTALLATION EXTERIOR SIGNED: 0211912015 NAN Y PLASTICSCORP. USA 5 iR -I LIp AE NT 8989 NORTHLOOP HOUSTON, TX 77029 ` v,•v�O+ENS�••J' FIBERGLASS GLIDING PATIO DOOR *• o�.S1251 W/ REINFORCED SIDELITES E`` INSTALLATION DETAILS �O TAT OF DRAWN: DWG NO. REV %'cFS'�[pR10P G A ////S/pNAl-i \�'� OS soEE6540� SCALE DATE NTS 07/03/12 5