HomeMy WebLinkAboutNOTICE OF PRODUCT CERTIFICATIONNOTICI W PRODUCT CERTIFI MON
CERTIFICATION' NO:
DATE:
CERTIFICATION PROGRAM:
COMPANY:
CODE:
REVISION DATE:
NI009467-R4
05/19/2007
Structural
Nan Ya
661-1
03/05/2015
To verify that the "Notice of Product Certification"is valid, please visit www.NAMICertif cation.com to assure that
the product is active and currently listed: This certification represents product conformity to the applicable
specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied
to the product to claim certification status. Please review and advise NAMI if any corrections are required to this
document
COMPANY NAME AND .ADDRESS
PRODUCT DESCRIPTION
Nan Ya Plastics Corporation USA
"Fiberglass Gliding French Patio Doors"
8989 North Loop East, Suite 800
w/Reinforced Sidelites
Houston, TX 77029
Fiberglass Sliding Glass Door
Configuration: OXXO
Glazing: IG-1/8" Tempered Glass/
Laminate-1/8" Annealed Glass/0:090" PVBby Solutia/
1/8" Annealed Glass
Frame: W-3585mm(141.13") H-2426mm(95.5")
Panel: W-908mm(35.75") H-2346mm(92.38")
SPECIFICATION
PRODUCT RATING
ANSI/AAMA/NWWDA 101/I.S.2-97
SGD-R50
TAS 201/202/203-94
Design Pressure: ±2400 Pa (50 psf)
ASTM E1886-02/E1.996-02
Large Missile Impact Rated
ASTM E1304-02
Wind Zone 4-Missile Level D
FER-Passed
Product Tested By: Certified Testing Laboratories
Report No: CTLA-1602W/CTLA-1602W-1/CTLA-1.602W-2 A.
Expiration Date: February 28, 2021 =' -lip
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes, VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122
95
r
FE
HE
141 Ilb MAX VKAML WIUIH
25" 35 3/4" MAX
D.L.O. PANEL WIDTH
79"
D.L.O.
92 3/8"
MAX
PANEL
HEIGHT
1/2"
UFIXED
IAX
AME
FIXED
ACTIVE
ACTIVE
IGHT
SERIES SPLS GLIDING PATIO DOUBLE DOOR W/ SIDELITES
EXTERIOR VIEW
DESIGN PRESSURE RATING
IMPACT RATING
±50PSF
LARGE AND SMALL
MISSILE IMPACT
MISSILE LEVEL D,'WIND ZONE 4 AND HVHZ
REVISIONS
DESCRIPTION DATE I APPROVED
REVISED DIMENSIONS 02/18/15 1 R.L.
NOTES:
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH
REQUIREMENTS OF THE FLORIDA BUILDING CODE.
2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD.
3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. WHERE 1X BUCK IS NOT USED
DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE.
SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR
ENGINEER OF RECORD.
4. UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEET 2 FOR GLASS DETAILS.
5. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND
BORNE DEBRIS REGIONS..
6. FRAME JAMB AND HEAD MATERIAL: CO=EXTRUDED PVC FOAM 1 1/2" THICK.
7. FRAME SILL MATERIAL: CO —EXTRUDED PVC FOAM 2" THICK WITH ALUMINUM CLADDING .063"
THICK.
8. DOOR PANEL AND SIDELITE MATERIAL: PVC FOAM TOP AND BOTTOM RAILS, AND PVC FOAM
VERTICAL STILES WITH PINE REINFORCEMENTS AND POLYURETHANE FOAM CORE.
9. APPROVED CONFIGURATIONS: OX, XO, AND OXXO. SEE SHEET 2.
7
,1
TyTABLE
OF CONTENTS
SHEET NO. DESCRIPTION
1 OXXO ELEVATION AND NOTES
2 ADDITIONAL CONFIGURATIONS ANCHOR LAYOUTS & HARDWARE
zzmtb,!
3 — 5 INSTALLATION DETAILS
NAN YA PLASTICS CORP. USA
8989 NORTH LOOP EAST
HOUSTON, TX 77029
FIBERGLASS GLIDING PATIO DOOR
W/ REINFORCED SIDELITES
OXXO ELEVATION AND NOTES
DRAWN: DWG N0. REV
A.P. 08-01664 A
SCALE NTS IDATE 07/03/12 1 SHEET OF 5
SIGNED: 0211912015
LL/0
�1///�i
E
* 051 -.
T((AATT*E OF
0�.
ZOR\Okip
'�'�F•'cP • \�a`�.
///�jpjS•��NA 11E�C?��\
D
c
71 7/8' 1-
71 7/8"
6
FIXED
4CTIVE
SINGLE W/SIDELITE
EXTERIOR VIEW
FIXED 4CTIVE
SINGLE W/SIDELITE
EXTERIOR VIEW
MULTI POINT
LOCK SET
LOCK
KEEPER
ASTRAGAL
STRIP
ASTRAGAL DETAIL
EXTERIOR
INTERIOR
REVISIONS
REV DESCRIPTION GATE APPROVED
A REVISED DIMENSIONS 02/18/15 R.L.
EXTERIOR
INTERLOCK STRIP
WEATHER STRIP
WEATHER STRIP
INTERLOCK STRIP
COVER
e
INTERIOR
MEETING RAIL DETAIL
5 3/4"
El
DOOR SILL
A. MULTI POINT LOCKING SYSTEM
B. (1) DIE CAST HANDLE SET PER ACTIVE PANEL
C. (2) STAINLESS STEEL TANDEM ROLLERS PER PANEL
D. PVC ASTRAGAL BY NAN YA PLASTICS
1"
1/8" ANN
090" PVB BY SOLUTIA
--{I 1/8" ANN
1/8" TEMP r
ALUMINUM
5/8" BITE SPACER
SYSTEM
} INTERIOR
EXTERIOR SILICONE
GLAZING DETAIL BEDDING
SIGNED: 0211912015
NAN YA PLASTICS CORP. USA
\\\\S lR I !Lf07j/�i�
8989 NORTH LOOPEAST
HOUSTON, TX77 29
FIBERGLASS GLIDING PATIO DOOR*�•/�
0y,.�6}�51//��''
W/ REINFORCED SIDELITES
a (iEK„l6st[;z�'
ADDITIONAL CONFIGURATIONS AND HARDWARE
�- STATEE ( 4�
ORA'NN:
DWG N0.
08
REv
A
%O��s'�CORID. G
/�/7S,r7NA11E?\\\\
SOE664
SCALE DATE
NTS 07/03/12 2 OF 5
95
7" 16"
MAX MAX 'I MAX
4" MAX
12
MAX
L
16"
MAX
O.C.
}
1/2"
i
4" MAX
ANCHORING LAYOUT FOR DOUBLE W/SIDELITES
EXTERIOR VIEW
ANCHORING NOTES:
1. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. SHIM WHERE
SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4".
2. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE
ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
3. FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH
TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 5'/8" MINIMUM EDGE
DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
4. ALL FASTENERS TO BE CORROSION RESISTANT.
5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD - MINIMUM. SPECIFIC GRAVITY OF G=0.42
B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI.
C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER).
- 7 MAX
DESCRIPTION
REVISED DIMENSIONS
REVISIONS
DATE I APPROVED
02/18/15 1 R.L.
.� 16" 7" _
1
4" MAX
12 MAX O.C.
`
16"
1
ANCHORING LAYOUT FOR SINGLE W/SIDELITE
EXTERIOR VIEW
NAN YA PLASTICS CORP. USA
8989 NORTH LOOP EAST
HOUSTON, TX 77029
FIBERGLASS GLIDING PATIO DOOR
W/ REINFORCED SIDELITES
ADDITIONAL CONFIGURATION AND HADWARE
A.P. I 08-01664
SCALE NTS — 07/03/12 1 SHEET OF 5
1
4" MAX
SIGNED: 0211912015
WOOD FRAMING
BY OTHERS
FLANGE TO BE SET IN A
BED OF APPROVED SEALANT
WON
EXTERIOR `j F-1 I r
II •: II I '�'�'a
SILL TO BE SET
IN BED OF
APPROVED
SEALANT
WOOD FRAMING
BY OTHERS
EDGE DISTANCE
1 3/8" MIN
EMBEDMENT
1 /4" MAX.
SHIM
#10 WOOD
SCREW
REVISIONS
REV DESCRIPTION DATE APPROVED
A I REVISED DIMENSIONS 1 02/18/15 1 R.L.
1 3/8" MIN �� _J 1 /4" MAX
EMBEDMENT I I SHIM SPACE
1/2" MIN.
EDGE DISTANCE \
INTERIOR WOOD FRAMING
BY OTHERS
GUVC UIJ IMIVVC
VERTICAL CROSS SECTION
DOOR SHOWN, SIDELITE SIMILAR
2X BUCK/WOOD FRAMING INSTALLATION
FLANGE TO BE
SET IN A BED
OF APPROVED SEALANT
— # 10 WOOD
SCREW
INTERIOR
EXTERIOR
BACKER ROD
AND APPROVED SEALANT
BY OTHERS
HORIZONTAL CROSS SECTION
2X BUCWWOOD FRAMING INSTALLATION
MIN NAN YA PLASTICS CORP. USA
BENT 8989 NORTH LOOP EAST
HOUSTON, TX 77029
FIBERGLASS GLIDING PATIO DOOR
W/ REINFORCED SIDELITES
INSTALLATION DETAILS
DRAWN: DWG NO.
A.P. 08-01664
SCALE NTS I DATE 07/03/12 ;EET4 OF 5
SIGNED: 0211912015
,R I IL/D,////
=*• 5
st�COyC�••*=
STATE OF
NA `I�?G`��
FLANGE TO BE SET IN
BED OF APPROVED SEALANT
1X BUCK BY OTHERS,
1X BUCK TO BE
PROPERLY SECURED
2 5/8" MIN.
EDGE DIST.
a A if a
MASONRY/CONCRETE
BY OTHERS
MIN.
EMBEDMENT
1 /4" MAX.
SHIM
3/16" TAPCON
EXTERIOR I `I rl l r INTERIOR
SILL TO BE SET
IN BED OF
APPROVED
SEALANT
MASONRY/CONCRETE
BY OTHERS
2 5/8" MIN. EDGE DIST. -"
VERTICAL CROSS SECTION
MASONRY/CONCRETE INSTALLATION
DOOR SHOWN SIDELITE SIMILAR
1 3/8" MIN
EMBEDMENT
1X BUCK BY OTHERS,
1X BUCK TO BE
PROPERLY SECURED
WOOD FRAMING
BY OTHERS
2 5/8" �.
MIN
EDGE
DISTANCE
a
FLANGED TO SET J
IN A BED OF
APPROVED SEALANT.
16" TAPCON
REVISIONS
REV DESCRIPTION DATE I APPROVED
A I REVISED DIMENSIONS 02/18/15 1 R.L.
1/4" MAX
SHIM SPACE
-- 3/16" TAPCON
INTERIOR
BACKER ROD
AND APPROVED SEALANT
BY OTHERS
HORIZONTAL CROSS SECTION
MASONRY/CONCRETE INSTALLATION
EXTERIOR
SIGNED: 0211912015
NAN Y PLASTICSCORP. USA 5 iR -I LIp
AE NT 8989 NORTHLOOP
HOUSTON, TX 77029 ` v,•v�O+ENS�••J'
FIBERGLASS GLIDING PATIO DOOR *• o�.S1251
W/ REINFORCED SIDELITES
E``
INSTALLATION DETAILS �O TAT OF
DRAWN: DWG NO. REV %'cFS'�[pR10P G
A ////S/pNAl-i \�'�
OS soEE6540�
SCALE DATE