Loading...
HomeMy WebLinkAboutREVISIONOFFICE USE ONLY: DATE FILED: —I-f REVISION FEE: 2. 9 4. 5. LOCATION/SITE ADDRESS: PERMIT # ©lX RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 FAX (772) 462-1578 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT n 7tSC>,e- BUILDING DIVISION FOR CO REVIEWED BY (li DATE CONTRACTOR INFORMATION: PLANS AND PE Mli MUa7' Sig KO� STATE of FL REG./CERT. #: Nile' j BUSINESS NAME: - QUALIFIERS NAME: r ADDRESS: r� ] r' CITY: Gave STATE:/,i' ZIP:'. OWNER//BBUILDER IN ION: NAME: R1 ",f 0!�-��� ADDRESS: O 7 CITY: i I zo= STATE: PHONE: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: PHONE (DAYTIME):• Revised 07/22/2014 FAX: ZIP: --jr 7,j / ply ZIP: FAX: REVISION Florida Building Code Online_ Page 1 of 4 S s '�..����-�,,.�,� BCIS Homey Log In i User Registration Hot Topics ' Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map I Links search i b a RECEIVED �'' _ p N., r01OUSER, Product Approval (l!!'''af�`� Public User GO 6� �"',� rrr.•4uc; 'vn;rr,�dai Nirn�� > Froduft or nnoiication Search > AonHcation Lis t > Application Detail 140V 2 0 28V • � FL # FL10181 R7 PERMITTING Application Type Revision St. Lucie County, FL Code Version = 2014 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments set to reapply per R. Lomas' s req.zb.03/09/16 Archived 0 Product Manufacturer Nan Ya Plastics Corporation USA Address/Phone/Email 8989 North Loop East Houston, TX 77029 (713) 674-7822 Ext 105 ajen96@yahoo.com.tw Authorized Signature RUSKIN WU ajen96@yahoo.com.tw Technical Representative Ruskin Wu Address/Phone/Email 8989 North Loop East Houston, TX 77029-1217 (713) 674-7822 Ext 105 ajen96@yahoo.com.tw Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sliding Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2008 ANSI/AAMA/NWWDA 101/I.S.2 1997 ASTM E1886 2002 ASTM E1996 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards � �1� ' P 1 Certified By — L LI https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMbmu... 11 /15/2017 Florida Building Code Online_ Page 2 of 4 Product Approval Method Method 1 Option A Date Submitted 01/11/2016 Date Validated 03/28/2016 Date Pending FBC Approval Date Approved 03/28/2016 Date Revised 07/26/2017 Summary of Products FL # Model, Number or Name Description 10181..1 GLIDING FRENCH DOOR NEUMA NON -IMPACT GLIDING 12'0" x 8'0" - OXXO, OX, XO, .6'0" x 8'0" GLAZED DP50 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL10181 R7 C CAC NI006116-R4.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/31/2021 Design Pressure: +50/-50 Installation Instructions Other: FL10181 R7 11 08-015.15B.vdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL10181 R7 AE 51211.)iC.ndf Created by Independent Third Party: Yes 10181.2 GLIDING PATIO DOOR FIBERGLASS GLIDING PATIO DOOR W/ REINFORCED SIDELITES - IMPACT Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL10181 R7 C CAC NI009467-R4.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 02/28/2021 Design Pressure: +50/-50 Installation Instructions Other: FL10181 R7 H 08-01664A .Ddf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL10181 R7 AE 51.23431; .Ddf Created by Independent Third Party: Yes :10181.3 Gliding Two Panel Patio Door Gliding, Two Panel Patio Door - Non -Impact Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL10181 R7 C CAC N1010809-R2.ndf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 07/31/2021 Design Pressure: +50/-50 Installation Instructions Other: FL10181 R7 11 08-01099C.odt Verified By: Luis R. Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL10181 R7 AE 51.1659B .odf Created by Independent Third Party: Yes 10181.4 MasterPiece Series Gliding Patio Door MasterPiece Series Gliding Patio Door, Nan Ya 6068 DP45 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL10181 R7 C CAC NI01.1609.od1 Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 04/30/2017 Design Pressure: +45/-45 Installation Instructions Other: FL10181 R7 II 08-02239A .odf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL10181 R7 AE 512959A .Ddf Created by Independent Third Party: Yes 10181.5 DOORS "NAN YA SLIDING GLASS I SERIES "NAN YA SLIDING GLASS DOOR" - 6'06'11 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: Certification Agency Certificate FL10181 R7 C CAC_N100__6928-R4.0CEr Quality Assurance Contract Expiration Date 02/28/2021 Installation Instructions FL10181 P7 II 08-01867Aydf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports https:Hfloridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDquracBeV CbdMbmu... 11 / 15/2017 Florida Building Code Online__, Page 3 of 4 IFL10181 R7 AE 512556B.odf Created by Independent Third Party: Yes 10181:6 SERIES "SRS GLIDING PATIO SERIES "SRS GLIDING PATIO DOOR WITH FIELD MULLION" DOOR WITH FIELD MULLION" FIBERGLASS SLIDING DOOR WITH SIDELITE - NON -IMPACT Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL10181 R7 _CCAC NI 110-3; -R -j?SIf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 03/31/2020 Design Pressure: +50/-50 Installation Instructions Other: F1_10181 R7 II 08-01533B.0f Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL10131 R7 AE 512174C odf Created by Independent Third Party: Yes 10181.7 SERIES "SRS GLIDING PATIO DOOR WITH FIELD MULLION" SERIES "SRS GLIDING PATIO DOOR WITH FIELD MULLION" FIBERGLASS SLIDING DOOR WITH SIDELITE Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL10181 R7 C CAC NI 11034-R2__1,Sf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes • 03/31/2020 Design Pressure: +50/-50 Installation Instructions Other: FL10181 R7 II 08-01534B.I)d Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports F1,10181 R7 AE 51.21.75C.oclf Created by Independent Third Party: Yes 10181.8 Series Gliding 3 Panel Patio Door Series Gliding 3 Panel Patio Door Sliding Door w/ Field Sliding Door Mullion - Non -Impact Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL10181 R7 C CAC NI011932-Ri.Pff Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 03/31/2018 Design Pressure: +50/-50 Installation Instructions Other: FL10181 R7 11 08-02362A.Ddf Verified By: Luis R. Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL10181 R7 AE 513129A.Ddf' Created by Independent Third Party: Yes 10181.9 SERIES SPLS GLIDING PATIO SERIES SPLS GLIDING PATIO DOOR - 120611 - NON - DOOR IMPACT Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL10181 R7 C CAC N1011356-R2.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 06/30/2020 Design Pressure: +50/-50 Installation Instructions Other: FL10181 R7 II 08-01897A.udf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL10181 R7 AE 5125896.0f Created by Independent Third Party: Yes 10181.10 SERIES SPLS GLIDING PATIO DOOR SERIES SPLS GLIDING PATIO DOOR - 120611 - IMPACT Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL10181 R7 C CAC NIU1135'.02-R1..t..idf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/30/2020 Design Pressure: +50/-50 Installation Instructions Other: FL10181 R7 II 08-01898A.D<If Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL10181 R7 AE 512590B.ndf Created by Independent Third Party: Yes 10181.11 SERIES SRS GLIDING PATIO DOOR I SERIES SRS GLIDING PATIO DOOR WITH FIELD MULLION - WITH FIELD MULLION 120611 - NON -IMPACT Limits of Use Approved for use in HVHZ: No . Approved for use outside HVHZ: Yes Impact Resistant: No Certification Agency Certificate FL10181 R7 C CAC Ni011355-R2.Ddf Quality Assurance Contract Expiration Date 06/30/2020 https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMbmu... 11 / 15/2017 Florida Building Code Online \ Page 4 of 4 ' l Design Pressure: +50/-50 Installation Instructions Other: FL10181 R7 II 08-01899A.ndf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL10131 R7 AE 512591B.odf Created by Independent Third Party: Yes 10181.12 SERIES SRS GLIDING PATIO DOOR WITH FIELD MULLION SERIES SRS GLIDING PATIO DOOR WITH FIELD MULLION - 120611 - IMPACT Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL10181 R7 C CAC NI011355.02-Rl.ndf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/30/2020 Design Pressure: +50/-50 Installation Instructions Other: FL10181 R7 Ii 03-01900A.udf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL10181 R7 AE 5125926.0f Created by Independent Third Party: Yes 10181.13 SIDE GTE ING PATIO DOOR W/ I NEUMA NON -IMPACT GLIDING 12'0 X 8-0 GLAZED, 4 PANEL Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FI 10181 R7 C CAC NI0110 37-Rl.ndf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 03/31/2020 Design Pressure: +50/-50 Installation Instructions Other: FL10181 R7 II 08-01552A.ndf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FI_10181 R7 AE 5121988.ndf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road Tallahassee K 32399 Phone: 850.487-1824 The State of Florida is an AA/EE0 employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. •Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Card Safe https:Hfloridabuilding.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDquracBeV CbdMbmu... 11 / 15/2017 NOTI( OF PRODUCT CERTL _ CATION CERTIFICATION NO: DATE: CERTIFICATION PROGRAM: COMPANY: CODE: REVISION DATE: NI010809-R2 08/11/2011 Structural Nan Ya 661-1 03/05/2015 To verify that the "Notice of Product Certification" is valid, please visit www.NAMICertification.com to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Nan Ya Plastics Corporation USA Series "Gliding Two panel Patio Door" 8989 North Loop East, Suite 800 Vinyl Sliding Glass Door Houston, TX 77029 Configuration: OX Glazing: Insulated Glass (Tempered) Frame: W-1813mm(71.38") H-2019min(79.5") Panel: W-908nun(35.75") H-1946mm(76.63") SPECIFICATION PRODUCT RATING AAMA/WDMA/CSA 101/I.S.2/A440-08 Class R-PG501813 x 2019 (71 x 80)-SGD Product Tested By: Florida Testing Laboratory, Inc. Report No: FTL 6550 Expiration Date: July 31, 2021 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 B TEIS; PIRC-DuCi SH01111,1 rlREIN if; DESIGNED Atii,-, MAMjF.A,,'J0RED* REOUI.','EIMENTS' (.,- TII;- i-LOPI-DA BillILDINC, ',"D,(:. OPENING , IQ AND X-L LOADS �TRUC-IURE. T-RAI.AlmG, AND 1SA.S-NRY !S TI-C ON-1-0'.11Y ()-- I'lif AFF.-CHIfEl"r Fp ,-F 3. 'A-.ERF 0? 81AX -lH:*f,K.NF6.-,*i I? 1..EiiS 1HAN 1 112" MNOC,. UNii MIDST HE AN,"HORM 'HIRCAUGH *THE. FRAME IN Al"MROANIF 111TH MANUFAC-ORER"z PUBLIHE[) IN,zIALk.A-FION' FWSP "JC"IONS. ANI.,HORS SHAi 1 BE AS!CNED iNIO MA-vCNIR.Y. ,0Nr;:ETE OR OTHER SUKTRATEE MATERIAL. 4. M.-CRE BUC1 THICKNESS 15 1 --- 1/2" )R GREATER, BUCK{ALL BE SECUREU..' FASTIF..N�10, TO MASONRY, f ONCRIETIE OR OTHER --TR:J,.T`-ER;l,'. SMBSTRATE. 1;IND0,14 UNITS DE 111N.-HOkED TIPROUCH 17F,'MlE '10 --EIURrHj *0,01) BJr'i, 'N A(-'CCRDAN(X 'Willl kJANUrA!l'rljN'E;,,.'.13 PUBLISHLU TISNALLAMON INSIRUCIM'S. 5. EUCKS 511-11ALL EX-lEN() BE-01.0 10,11ND0,01 :tJI-RI-OR �.',"E 1,0 71-41`2 ; FRAME SUPPORT S ..T 1 E. FOR FIN IN'STALL,",110N AS NEEDED. FOR FkAMIE INSFAL.U01*10M SHIM AS REQUIRED Al f-ACH ANICHOR LOCATION Will-.' LOAD 8;.--.ARI.NC SHIN4. SHIM 'WI-IFRE SPACE OF 11/16" �P GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK 'TO BE 11/4". 1. SH-jf.; ;HALL HREv LOCATEDAPPLiFD AND MADE FROM MATER'ALS AND THICKNESS CAPABLE (117 SUSIAIN111,10 APPLICA131.1 LOADS. F. 1AM) ;_DAD EDURADON FACTOR Cd=11.6 -NAS US. M FOR MOOD ANCHOR 0AJ-GU1.AT:--.;NS. 9. UNITS G.J...A.ZED PER "'S-DA E1300-04, S�— SHEET 71 FOR C;L,-.SS DETAILS. 10. APPR(MO I.M.PACC! PROTECTIVE -.;Y!;TFiA IS PEQUIRE'l TOR IHIS PRODUCT ill vNIND BORNE DEBRIS REC110INIS. 2 INTO Or 2X BUCK U c; E %10011 SCREY.is IN: . SU`.*F!e-'IEIJ*T LENGTH To ACHIEVE A. 1 3".'r MiN3.4UM EM.LEDIME11,11 INTC.- ANCH-ORS AS SHOIN11 IN ELE"If,'MONS AN,"; INSTALA-10M DET I -S. ......... ...... ..... ...... . . . .......... . . . . ........... . ............... . . ........ 12. T'.') 6E -Sw(.*-N AN;.'r;-3R::; SHA WiTI-1 LE'S'S NIAI-4 ;-.4;N3,11 , M c; 9, 4 2 F R A M t— JA M B A&i 13 F I EAD MAT �R; 'I',* E I) P`V C. FOAM Ti'" PVf—' Fl?,A?l I 1/:2­ TL;Z:' I, 15. DOOR PANCL MATERIAL: F17-A'm VviTii Ak EXTRUDED SKIN -('31" MICK. 17. -APPROVED C0N-i,;ij-rATI6NS: X0, OX. TA"LL OF N)INTEIM, . ...... . . . ... ........................ . .... ..... ........ . .......... . . ........... . . . ...... . ..... ................. ... 1 NOTES .. . . . .... ........ 2 A:.Ir--;.0RII%lG ci.YCjT IN.SfALLANON OF"Ail.5, 4 :X.fAll. AM") NAN YA PLASTICS CORP. 8989 NORTH LOOP EAST HOUSTON. TX 77029 GLIDING TWO PANEL PATIO DOOR 71 3/8" x 79 1/2" ELEVATION. ANCHORING LAYOUT SIGNED: 0211912015 USA o.11111'kI1111, to TATt OF fJH 08-0 1 099 "' " NTS PI :1. 08/19/10 I S:"' 1 OF 4 — --------- -- 7- 3118 Fr-AME '1;![:Ti . ...... ­ ......... . .. ....... . . . . ...... ... . ... :i/4" ',IAX. �4 9 .. ........ . . ... ... ... ....... .. ........ .. . T_ PANEL Hic-IGH Y —7 MAY. VAX. RAM:` HE GHT iElGI �T 38 7/8" / 0% . ...... ... ..... . ...... GLIDING TWO PANEL PATIO DOOR EXTERIOR VIEW DESIGN PRESSURE RATING IMPACT RATING ±50PSF NONE ...... ........... . .. . .. ­­­ .... . . . . .. . .... . ........ .............. ..... .... . ... . .......... .... . .......... r7,i,3Efl :_n HEW Flc�_t.:J..-,rt,­�: f: PLAS11, r *1 S! NAN YA PLASTICS CORP. USA 8989 NORTH LOOP EAST HOUSTON, TX 77029 GLIDING TWO PANEL PATIO DOOR 71 3/8" x 79 1/2" ELEVATION. ANCHORING LAYOUT DPAN, 7wic., TJH 08-01099 NTS 08/19/10 2 OF 4 SIGNED: 0211912015 Lx N\ X I I I 11. 1111 /Z NSF` tp •. =-A • TATE OF OUNCE 'p F I L- ... . ............. . .... .. . AND 'N 1 F R.10H Fiji!:;" BY PIW! S L GE DISTANCE EXTERIOR ........ ...... ... 12 A INTERIOR " 2X iIU-,K 'WOOD FRAMING Dr OTHERS, 2X �'�WCK M BE PROPERLY SEVAR,r'.1" EXTEMIOR FINISH . ............... . .............. BY SILL f0 BE SCT IN SEALANT -zu VERTICAL CROSS SECTION 2XBUCKIWOODFRAMING . ........ . . . .. P7;15M, NITIN FllMk.;P7%-.rN--;. - - --------- -, -- 11/4" M."Y.. Sl 4!11! INTERIOR ........... ... . . . ..... . ... .............. ... ------ -- - -- -- ......... ...... ............ . . t T .711,1 H [j - --------- EXTERIOR HORIZONTAL CROSS SECTION ..... . ...... ---.. . .................. . . 2X BUCKIWOOD FRAMING NAN YA PLASTICS CORP. USA 8989 NORTH LOOP EAST HOUSTON, TX 77029 GLIDING TWO PANEL PATIO DOOR 71 3/8" x 79 1/2" INSTALLATION DETAILS TJH 08-01099 ,77 C'NTS." 08/19/10 15�-�`"3 OF 4 SIGNED: 0211912015 a Lol 41 0 5 TIAT04 0 • -�Z 0 RVOt.- Piyo— \N ..�6 i ! 5 314" FRAME HEAD AND JAMB CO -EXTRUDED PVC FOAM .75• THICK i S ....._._._.-..._.. _._r-'.._....:.._._..._........__��.............._:.. ..._..............1... } 4 314" GLIDING SILL CO -EXTRUDED PVC FOAM 1.032' THICK 4 514.. IfI. 4 314" STILE AND TOP RAIL PVC COMPOSITE FOAM WITH .031 • THICK EXTRUDED PVC SKIN 6 518" BOTTOM RAIL PVC COMPOSITE FOAM WITH .031" THICK EXTRUDED PVC SKIN 4 THRESHOLD EXTRUDED ALUMINUM 6063-T6.059" THICK _, ..., 1 17 .3'r IL 19 _ a S_C_R_EEN_RAIL EXTRUDED ALUMINUM 6063-T6.059' THICK FRAME FIN EXTRUDED RIGID PVC.051"THICK 1 " GLAZING BEAD EXTRUDED RIGID PVC.039"THICK } PANEL BOTTOM_ RAIL OCIAfCP10fl0AA=AM PANEL STILE REINFORCEMENT PINE JAMB REINFORCEMENT PINE MEETING STILE INTERLOCK CO -EXTRUDED PVC FOAM .75" THICK HARDWARESCHEDULE :.................................................................._.._.._........._...—-.._.._:............_....._........................_.._.........._.............._....._. A. A;J:;STAF..L.E RO!..I..ER r: PER A.—rlvi'. 1=ANEL __.._....._..._.._____._._...____.__.__.._ _^--- ----- .... ----_--- _.._...._-- i3 I`;;• DOLT :4ii KEE^_k ;I', +OF CC ACTIVE `.AtlEL itrf LCGKIPIG - `". '?rt';H ie. t- F.? ('), PER \Cfl%.-E i ;i. �;i.li?(!t'• F; A�:JL.[. •.._I ;� PIP IV, WE pi;'J'cL .::. r INTERIOR EXTERIOR (� J 004E CORNING, !,99 i C!I_I�. NE: GLAZING DETAIL SIGNED: 0211912015 NAN Y PLASTICSCORP. USA \\51111111111// " 8989 N HOUSTON, TX 77029 i *• 0,,6�61 •• GLIDING TWO PANEL PATIO DOOR 71 3/8" x 79 1 /2" b • (�(r •a= �j I COMPONENTS,GLAZ NG DETAIL AND HARDWARE STAT 70 . E OF ��/�SS/ TJH 08-01099 C �i�IIQNA r iT=! , �'== NTH "` 08/19/10 4 OF 4 i L. Roberto Lomas P.E. 233 W. Main St Danville, VA24541 434-688-0609 rllomas ilirlomaspe.com Manufacturer: Nan Va Plastics Corp. USA 8989 North Loop East Houston, TX 77029 Product Line: Gliding Two Panel Patio Door - Non -Impact Engineering Evaluation Report Report No.: 511659E Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a). The product listed herein complies with requirements of the Florida Building Code. Supporting Technical Documentation: 1. Approval document: drawing number 08-0109% Revision C, prepared, signed and sealed by Luis Roberto Lomas P.E. 2. Test report No. FTL 6550 signed by Manny Sanchez. Fenestration Testing Laboratory Inc. Medley, FL AAMANVDMA/CSA 101/I.S.Z/A440-08 Design pressure: ±50.Opsf Water penetration resistance 7.5psf 3. Anchor calculations, report number 511659-1, prepared, signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use. • Maximum design pressure: ±50.Opsf • Maximum unit size: 71 3/8" x 79 1/2" • Approved configurations: XO and OX • Units must be glazed per ASTM E1300-04, see installation instructions for glass details. • This product is not rated to be used in the HVHZ. • This product is not impact resistant and requires impact protection in wind bome debris regions. Installation: Units must be installed in accordance with approval document, 08-01099, Revision C. Certification of Independence: Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other entity involved in the approval process of the listed product(s). ����tittitrilt� AN 0 0 51 TAT OF ,• cc�, Ali stONAL 1 of 1 Luis R. Lomas, P.E. FL No.: 62514 03/30/2015