Loading...
HomeMy WebLinkAboutCERTIFICATE OFT TERMITE TREATMENT - 3-7-184 Planning & Development erVICeS , Building & Code Regulation Division w 2300 Virginia Ave • Fort Pierce, FL 34982 772-462-2172 Fax 772-462-6443 CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT / JOB ADDRESS: ........ y� ll �t ESL 3 Y PERMIT # s BUILDER/CONTRACTOR: jc PEST CONTROL CONTRACTOR: EVICT -A -BUG TERMITE & PEST CONTROL INC. PEST CONTROL LICENSE #: jB1 a ion We, the undersigned, hereby certify that we have pretreated the above described ndards of the National Pest Control gssoc`iat onor subterranean termites in accordance with the sta Square feet if area treated: Percentage of solution: •05°1° Date of Treatment: 4/4� Footing _ 41St Treatment Re -Treat Driveway 1st Treatment Re Treat Other 1st Treatment Re -Treat Chemicals used: DOMINION 21. Total gallons used: 2- f0 Time of Treatment: &-: o E Slab St Treatment Re -Treat Pools 1st Treatment Re -Treat Perimeter for Final Inspection 34a'tel Si ure of Exterminator Note: There must be a completed form for each required treatment or re -treatment and this form must be on the job site to be picked up by the Inspector at time of each Inspection or the scheduled Inspection w111 fall and a re -Inspection fee charged. FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resistant jobsite posting board shall be provided to recelve duplicate Treatment Cerdflcates as each required protective treatment /s completed, provlding a copy for the person the permit is issued to and another copy for the building permit tiles The Treatment Certificate shall provide the product used, Identity of the applicator, time and date of the treatment, site location, area treated, chemical used, percent soil chemical barrier method for tencentration and number of rmite prevllons ention Isto aused, final elle record of rior treatment shall protective treatment: I royal. be completed prior to final building app St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing all the treatments and dates of applications. Rcviocd 7/24/2014 J 469 KSM ENGINEEPING PAGE 01/01 03 02 2018 15:57 77/ 8 6 Z%I JAVJL KELLER, SCHLEICHER &. MacWILLIAM ENGINEERING AN17 TESTING, INC. MARTIN (772) 337-7755 PO. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772..) 589-0712 PALM BEACH (561) $45-7445 FAX (56www.ksmengineering,net . MELBOURNE (321) 7G8-8488 C.A.: 56 9$ 845-5$76 FAX E-Mail; KSM@KSMENGINEERINC.NET ST. LUCIE (772) 229-9093 SOIL COMPACTION REPORT FAX (772) 589-6469 ASTM D 1567 and ASTM D 2922 DATE TESTED : March 2, 2018 PERMIT # 170"614 CONTRACTOR Southern Standard Builders JOB LOCATION 7437 Gullotti Place Port St Lucie, Florida ITEM TESTED - ' Compacted Foundation Fill KSM JOB # : 180739-1d/MH/ct MAR , 2 2010 TEST LOCATION DEPTH * PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. N.W. 0" -12" 56 116.4 118.9 97.9 2. N.E. It 55 116.7 IV97.3 3. Center 50 114.0 If 95 g 4. S.W. 68 118.7 of 9 5. S.E_ It 54 116.5 99.8 . Soil Description: Brown Sand with Shell Fragments In Place Moisture: 7.4 Percent Optimum Moisture: 11.6 Percent Max. Dry Density: 118.9 P.C.F. @ Test Locations The Density & Penetrometer Readings Indicate the Degree of Compaction Meets to Natural Grade. ti Le=le(a�pellsouth. net Lucie C t Moisture - % of Dry Weight Sle Copy PARTIAL.. APPROVAL .,rr.. oun y Building Department Ronald G. Kellrr. RE.: 37293 / 81 l ic. No.: 860 / Julie E. Keller, RE.: 68366