HomeMy WebLinkAboutENERTGY EFFICIENCY CODEP�e r i�08 -0�1�
/v t✓ r-1- CO3t4,G'lC::0'vV
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: GROENWOLDT RESIDENCE
Builder Name: HELMET HOUSE CONSTRUCTION
Street: 7437 GULLOTTI. PLACE
Permit Office: ' ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE , FL, 34952
Permit Number: 1708-0614
Owner. EDWARD.AND SHAWNA GROENWOLDT
Jurisdiction:
Design Location: FL, Fort Pierce
County:: Indian River (Florida Climate Zone 2 )
1. New cons on or existing New (From Plans)
9. Wall Types, (2022A sgft.)
nsulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 2022.90 ft2
3. Number of units, if multiple family 1
b. N/A
c. N/A
R= ft2
R= ft2
4. Number of Bedrooms 3
d. N/A
_ ft2
5. Is this a worst case? No
Insulation rea
R=20.0 2010.00 ft2
6. Conditioned floor area above grade (ft2) 2010
I!f=R
Q.
R= ft2
Conditioned floor area below grade (ft2) 0
z
R= ft2
Win ows (284.0 s Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
R ft2
6 175
a. U-Factor: Dbl, U=0.32 142.00 ft2
SHGC: SHGC=0.22
b. U-Factor: Dbl, U=0.35 80.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.20
a. Central Unit
36.0 8EER:16.00
c. U-Factor. Dbl, U=0.35 48.00 ft2
SHGC: SHGC=0.12
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. other (see details) 14.00 fe
a. Electric Strip Heat
27.0 COP:1.00
SHGC: other (see details)
Area Weighted Average overhang Depth: 1.500 ft.
Area Wei SHGC:
14. Hot water systems
8. Floor Types (2010.0 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge.insulation R=0.0 2010.00 ft2
b. Conservation features
EF: 0.980
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.141 Total Proposed Modified Loads: 62.75
PASS
Total Baseline Loads: 71.86
I hereby certify that the plans and. specifications covered by
Review of the plans and
Srgp�
this calculation are in compliance with the Florida Energy
specifications covered by this
O�EIE
v
Code. K
calculation indicates compliance
.„''�' VIN
UJM
with the Florida Energy Code.
iv nn'��'
,�
PREPAR D
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
. t,
I hereby certify that this buildi des red, is in compliance
Florida Statutes.
With the Florida Energy C
Cab WF
OWNER/AGE T
BUILDING OFFICIAL:
DATE: I
DATE:
- Compliance requires; certification .by the alr handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.11.
- Compliancerequires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017
this project requires an envelope leakage test report with envelope leakage no greater than 7.6 ACH50 (R402.4.1.2).
s rile Copy'
10/9/20171:07 PM EnergyGauge® USA - v5.1 -Section R405.4.1 Compliant Software Page 1 of 6
.FORM R405-2014
PROJECT
Title: GROENWOLDT RESIDENCE
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 2010
Lot #
Owner. EDWARD AND.SHAWNA GR
Total Stories: 1
Block/SubDivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name: HELMET HOUSE CONSTRU
Rotate Angle: 0
Street:
7437 GULLOTTI PLAC
Permit Office: ST LUCIE COUNTY
Cross Ventilation: No
County:
Indian River
Jurisdiction:
Whole House Fan: No
City, State, Zip:
PORT ST LUCIE
,
FarimiIy Type: Single-family
FL, 34952
New/EAsting: New (From Plans)
Comment:
CLIMATE
/
IECC Design Temp
Int Design Temp
Heating
Design
Daily Temp
V Design. Location TMY Site
Zone 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO BEACH_MUNI 2 39
90
70
75
299
62
Low
BLOCKS
Number Name r ^ Area
Volume
1 Entire,House 2010
20569.6
SPACES
Number Name -Area
Volume kitchen Occupants.
Bedrooms
Infil ID
Finished Cooled
Heated
1 KITCHEN 247
2321.8 Yes
0
1
Yes
Yes
Yes
2 BATH 2 63
592.2 No
0
1
No
Yes
Yes
3 UTILITY 136
1278.4 No
0
1
Yes
Yes
Yes
4 CLST 12
112.8 No
0
1
Yes
Yes
Yes
5 BEDROOM 3 173
1626.2 No
D
1
1
Yes
Yes
Yes
6 FOYER 91
855.4 No
0.
1
Yes
Yes
Yes
7 GREAT ROOM 555
6604.5 No
0
1
Yes
Yes
Yes
8 BEDROOM.2 177
1663.8 No
0
1
1
Yes
Yes
Yes
9 CLST.2 12
112.8 No
0
1
Yes
Yes
Yes
10 M W IC 2 42
394.8 No
0
1
No
Yes
Yes
11 M BATH 144
1353.6 No
0
1
Yes
Yes
Yes
12 M TOILET 28
263.2 No
0
1
No
Yes
Yes
13 M WIC 42
394.8 No
0
1
No
Yes
Yes
14 MASTER SUITE 288
2995.2 No
0
1
1
Yes
Yes
Yes
FLOORS
_. # Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation KITCHEN 261 0
247 ft2
1 0
0
2 Slab -On -Grade Edge Insulation BATH 2 1 ft 0
63 ftz
1 0
0
3 Slab -On -Grade Edge insulation UTILITY 30 ft 0
136 ft2
0
0
4 Slab -On -Grade Edge Insulation CLST E ft 0
12 ft2
.__
1 0
0
10/9120171:07 PM EnergyGauge® USA - vs. I - Section R405.4.1 Compliant Software Page 2 of 6
FORM .R405-2014
FLOORS
# Floor Type -
Space Perimeter Perimeter R-Value
Area
Joist. R-Value _ -_
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulation
BEDROOM 3 24 ft
0
173 ft2
_w
1
0
0
6 Slab -On -Grade Edge Insulation
FOYER 13 ft
0
91 ft2
0
0
7 Slab -On -Grade Edge Insulation
GREAT ROOM 17 ft
0
555 ft2
1
0
0
8 Slab -On -Grade Edge Insulation
BEDROOM 2 26 ft
0
177 ft2
1
0
0
9 Slab -On -Grade Edge Insulation
CLST 2 6 ft
0
12 1`12
__e
1
0
0
10SIab-On-Grade Edge Insulation
M WIC 2 1 ft
0
42 ft2
1
0
0
11SIab-On-Grade Edge Insulation
M BATH 21 ft
0
144 ft2
1
0
0
12SIab-On-Grade Edge Insulation
M TOILET 1 ft
0
28 f?
1
0
0
13SIab-On-Grade Edge Insulation
M WIC 1 ft
0
42 ft2
____
1
0
0
14SIab-On-Grade Edge Insulation
MASTER SUITE 43 ft
0
28812
1
0
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
# Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Hip
Metal 2248 ft2
0 ft2
Light
0.6
No
0.9
No
20
26.6
ATTIC
# Type
Ventilation
Vent Ratio (1
in)
Area
RBS
IRCC
1 Full attic
Unvented
0
2010 ft2
N
N
CEILING
Att
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Unvented)
'KITCHEN
20
Blown
247 ft2
0.1
Wood
2 Under Attic (Unvented)
BATH 2
20
Blown
63 ft2
0.1
Wood
3 Under Attic (Unvented)
UTILITY
20
Blown
136 ft2
0.1
Wood
4 Under Attic (Unvented)
CLST
20
Blown
12 ft2
0.1
Wood
5 Under Attic (Unvented)
BEDROOM 3
20
Blown
173 ft2
0.1
Wood
6 Under Attic (Unvented)
FOYER
20
Blown
91 ft2
0.1
Wood
7 Under Attic (Unvented)
BEDROOM 2
20
Blown
177'ft2
0.1
Wood
8 Under Attic (Unvented)
CLST 2
20
Blown
12 ft2
0.1
Wood
9 Under Attic (Unvented)
M WIC 2
20
Blown
42 ft2
0.1
Wood
10 Under Attic.(Unvented)
MBATH
20.
Blown
144ft2
0.1
Wood
11 Under Attic (Unvented)
MTOILET
20
Blown
28ft2
0.1
Wood
12 Under Attic (Unvented)
MWIC
20
Blown
42 ft2
0.1
Wood
13 Under Attic (Unvented)
MASTER SUITE
20
Blown
288 ft2
0.1
Wood
14 Under Attic (Unvented)
GREAT ROOM
20
Blown
555 ft2
0.11
Wood
6M
1019/20171:07 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2014
WALLS
Adjacent
Spacee
Cavity
Width
EtFt
Height
Sheathing Framing
Solar
Below
o
_ 1
E
Exterior
Concrete Block - Ext Insul KITCHEN
4.1
14.
0
9
4
130.7 f12
0
0
0.6
0
_ 2
S
Exterior
Concrete Block - Ext Insul KITCHEN
4.1
3
0
9
4
28.0 ft2
0
0
0.6
0
_ 3
N
Exterior
Concrete Block - Ext Insul KITCHEN
4.1
9
0
9
4
84.0 ft2
0
0
0.6
0
_ 4
E
Exterior
Concrete Block - Ext Insul UTILITY
4.1
6
0
9
4
56.0 ft2
0
0
0.6
0
_ 5
W
Exterior
Concrete Block - Ext Insul UTILITY
4.1
5
0
9
4
46.7 ft2
0
0
0.6
0
6
N
Exterior
Concrete Block - Ext Insul UTILITY
4.1
19
0
9
4
177.3 ft2
0
0
0.6
0
- 7
N
Exterior
Concrete Block - Ext Insui CLST
4.1
6
0
9
4
56.0 ft2
0
0
0.6
0
8
S
Exterior
Concrete Block - Ext InsditEDROOM 3
4.1
2
0
9
4
18.7 ft2
0
0
0.6
0
_ 9
W
Exterior
Concrete Block - Ext InsMEDROOM 3
4.1
15
0
9
4
140.0'ft2
0
0
0.6
0
_ 10
N
Exterior
Concrete Block - Ext InstBEDROOM 3
4.1
7
0
9
4
65.3 ft2
0
0
0.6
0
_ 11
W
Exterior
Concrete Block - Ext Insul FOYER
4.1
13
0
9
4
121.3 ft2
0
0
0.6
0
_ 12
E
Exterior
Concrete Block - Ext InsiBREAT ROO
4.1
13
5
11
11
159.9 ft2
0
0
0.6
0
_ 13
S
Exterior
Concrete Block - Ext Ins2EDR00M 2
4.1
8
0
9
4
74.7 ft2
0
0
0.6
0
14
W
Exterior
Concrete Block - Ext InsL9EDR00M 2
4.1
15
_0
9
4
140.0 ft2
0
0
0.6
0
_ 15
N
Exterior
Concrete Block - Ext Insd3EDROOM 2
4.1
3
0
9
4
28.0 ft2
0
0
0.6
0
=16
S
Exterior
Concrete Block - Ext Insul CLST 2
4.1
6
0
9
4
56.0 ft2
0
0
0.6
0
_ 17
S
Exterior
Concrete Block - Ext Insul M BATH
4.1
16
0
9
4
149.3 ft2
0
0
0.6
0
_ 18
W
Exterior
Concrete Block - Ext Insul M BATH
4.1
5.
0
9
4
46.7 ft2
0
0
0.6
0
_ 19
E
Exterior
Concrete Block - Ext InsWASTER SUI
4.1
16
0
10
4
165.3 ft2
0
0
0.6
0
20
S
Exterior
Concrete Block - Ext lnshAASTER SUI
4.1
18
0
10
4
186.0 1`12
0
0
0.6
0
21
N
Exterior
Concrete Block - Ext InsBLASTER SUI
4.1
9
0
10
4
95.0 ft2
0
0
0.6
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width,
Height
Area
Ft
in
Ft In
1
E
Insulated UTILITY
None
.39
3
6 8
20 ft2
WINDOWS
F4V
Orientation shown is the entered, Proposed
orientation.
Wall
Overhang
gOmt
ID
Frame Panes NFRC U-Factor SHGC
Area
Depth
Separation
int Shade
Screening
1
E 1
Vinyl Low.-E Double Yes
0.32
022
27.0 ft2
1 ft 6 in,
1 ft 4 in
None
None
2
W 5
Vinyl Low-E Double Yes
0.28
0.23
4.0 f12
1 ft 6 in
1 ft 4 in
None
None
3
N 6
Vinyl Low-E Double Yes
0.32
0.22
9.0 ft2
1 ft 6 in
1 ft 4 in
None
None
4
W 9
Vinyl Low-E Double Yes
0.32
0.22
30.0 ft2
1 ft 6 in
1 ft4 in
None
None
5
W 11
Vinyl Low-E Double Yes
0.35
0.12
48.0 1`12
1 ft 6 in
1 ft4 in
None .
None
6
E 12
Vinyl Low-E Double Yes
0.35
0.2
40.0ft2
1 ft6in
1 ft4,in
None
None
7
E 12
Vinyl Low-E Double Yes
0.35
0.2
46.0 ft2
1 ft 6 in
1 ft 4 in
None
None
8
W 14
Vinyl Low-E Double Yes
0.32
0.22
30.0 ft2
1 ft 6 in
1 ft 4 in
None
None
9
S 17
Vinyl Low-E Double Yes
0.28
0.23
6.0 ft2
1 ft 6 in
1 ft4 in
None
None
10
W 18
Vinyl Low-E Double Yes
0.28
0.23
4.0 1`12
1 ft 6 in
1 ft 4 in
None
None
11
E 19
Vinyl Low-E Double Yes
0.32
0.22
30.0 ft;
1 A 6 in
1 ft 4 in
None
None
12
S 20
Vinyl Low-E Double Yes
0.32
0.22
16.0 ft2
1 ft 6 in
1 ft 4 in
None
None
PON
10/9/20171:07 PM EnergyGauge® USA - v5.1- Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2014
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000455
2399.8 131.74 247.76 .3323 7
HEATING -SYSTEM.
# System Type
Subtype
Efficiency Capacity_ - _ _ _ Block
Ducts
1 Electric Ship Heat
None
COPA 27k13tu/hr 1
sys#1
COOLING' SYSTEM'
# System Type
Subtype
Efficiency Capacity - Alr-Flow 'SHR' Block
Ducts
1 Central Unit
Split
_
SEER: 16 36 kBtu/hr 1680, cfm 0.8 1
sys#1
HOT WATER SYSTEM
# System Type SubType
_ Location
EF Cap. Use . - SetPnt _Conservation
- 1 Electric None
UTILITY
0:98 40 gal 60.9 gal 120.deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft=
_
DUCTS
/ = Supply'—
V # Location R-Value . Area
— Return -- Air CFM 25' CFM25
Location Area. Leakage Type Handler TOT OUT ON RLF
HVAC #
Heat Cool
1 Attic „ _ 8 175 ftz
Attic
18 ft2 Default Leakage Attic (Default) c(Default) c_
1 1
TEMPERATURES
Programable Thermostat: N
Cooling Jan [[ ]] Feb. [[]� Mar
Heating (Xt Jan (X] Feb iXl Mar
[[ ]]Jan [[ ]] Feb [[xX]} Mar
Ceiling Fans:
Apr [ ].May (X� Jun (X� Jul [X� AugX� Se Oct M Nov
[ ] APr [ ]May [ ]Jun [ I:JuI [ j Aug' [ 1 S Oct Nov
[X) A r[;)Ma [) Jun [ j Jul [ ] Au , [) S Oct Nov
r 1 Dec
[XI DecVenting
[ ] Dec
1019/20171:07 PM EnergyGauge® USA -,v5.1 - Section R405A.1 Compliant -Software Page 5 of 6
FURM R405-2014
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)
AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (W D)
AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
"PM
65
68
65
68
65
68
65
.68
65
68
65
.68
65
68
68
68 ..
68
68
68
68
68
_ .68 _
68
68
U
10/9/20171:07 PM EnergyGaugeO USA - v5.1 - Section R405.4.1 Compliant Software Page 6 of 6
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: GROENWOLDT RESIDENCE Builder Name: HELMET HOUSE CONSTRUCTION
Street: 7437 GULLOTTI PLACE Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE , FL, 34952 Permit Number: 1708-0614
.Owner: EDWARD AND SHAWNA GROENWOLDT Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT_.
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints In the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
_
The air barrier in any dropped ceiling/soffit shall -be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall -doors .to unconditioned
attic spaces, shall be sealed.
Corners and headers shall be. insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal-envelope'insulation for framed Walls shall be installed in
substantial contact and continuous alignment with the air barrier..
Knee walls shall be -sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall beinstalled to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow Cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
_
s aces. _
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures Installed in the building thermal envelope shalt be
airtight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be -cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to
available space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
_..
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall 6e installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
1019/20171:08 PM EnergyGauge® USA - v5.1 - Section 11405.4:1 Compliant Software Page 1 of 1
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 87
The lower the EnergyPerformance Index, the more efficient the home.
7437 GULLOTTI PLACE, PORT ST LUCIE, FL, 34952
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area.(ftz)
7. Windows•' Description
a. U-Factor: Dbl, U=0.32
SHGC: SHGC=0.22
b. U-Factor: Dbl, U=0.35
SHGC: SHGC=0.20
c. U-Factor. Dbl, U=0.35
SHGC: SHGC=0.12
d. U-Factor: other (see details)
SHGC: other (see details)
Area Weighted Average Overhang Depth:
,Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. NIA
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
2022.90 ft2
b. N/A
R=
ft2
1
c. N/A
R=
ft=
3
d. WA
R=
ft2
No
10. Ceiling Types
nsulation
Ar
a. Roof Deck (Unvented)
R=20.0
2010.00 ft-
2010
b. N/A
R=
ft2
Area.
c. NIA
R=
ft2
:
142.00 ft2
11. ucts
R ft=
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
80.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
48.00 ftz
a. Central Unit
36.0 SEER:16.00
14.00 ft2
13. Heating systems
kBtu/hr
Efficiency
1.500 ft.
a. Electric Strip Heat
27.0
COP:1.00
0.198
Insulation Area
R=0.0 2010.00 ft2
R= ft2
R= ft2
14. Hot water systems
a. Electric Cap: 40 gallons
EF: 0.98
b. Conservation features
None
15. Credits None
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving f tures.which will be installed (or exceeded)
in this home before final- inspection. Otherwis , new EPL Display Card will be completed
based on installed Code co ' lit f res.
Builder Signature: Date:
Address of New Home: W?J 7 6"Np*'� PL City/FL Zip: PO4 S 4, L^ctc�
�L 6-[ -1
*Nate: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
10/9/20171:07 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page i of 1
Customer Detailed Quote # 632210
Quote Date: 01/24/2017
Ship To Customer
Ship To# A03663
ABC SUPPLY CO, INC #499
3680 SE DIXIE HIGHWAY 011917-499
STUART, FL 34997-5247
Phone# Fax# (772) 283-3928
Stuart #499 Cash Customer
Fax#
Line #
Item Description
Quantity
Line Pricing
0001
MULTI -PART MULTI -PART UNITS
Ordered:
List Price Sell Price
Ext Price
(1.00)
73.25X62.X.,5500,TW,FCTRY ML,W,.625FLANGE,EQUAL
1.00
$0.00 $1,055.21
$1,055.21
BEGIN MODEL SET 001::::::::::::::::::::::::::::::
Series: 5500.0000
{
Combination Configuration: TW
Unit 2. SH5500.FM
Unit 1 Bottom Left Unit): SH5500.FM
ff Frame Type:.625FLANGE
Width Equal Width: EQUAL
f.
Assembly Options: FCTRML
i or
Mull Part Selection: MULUCVR/CLPS
I Size Slection: ACTUAL
Width: 73.2500
Height. 62.0000
-- ^ -- — ---
Vertical Mull: 1.25X3.25X.62FM
Frame Color: White
Glass Color: CL
Boxing Options: N
Location:
0001 SH5500 VINYL SINGLE HUNG 5500 T Ordered: ^TList Price _ Sell Price 6 Ea Price
(2.00) MULL EXTANT COVERS & CLIP SET,.,36.X62.X.,STD,5/8" 1.00 $795.90 $0.00 $0.00
FL,W,EQUAL,7/8 LIG,CL,SB 70XL,NO
GRID,SWEEP,1816K,CMFRT LFT HNDL,.x.
Certification Type: MIAMI
NOA Selection: 16-0714.03
Frame Type:.625FLANGE
Vent Configuration: EQUAL
Window Style: STD
Size Selection: CUSTOM
Size Ref: ACTUAL
Actual Size: 36 X 62
i
Rough Masonry: 37 3/4 X 63
Wood Frame: 361/4 X 621/4
Egress: 31 3/4 X 26 3/8 (5.808 SQFT)
Frame Color: White
Does unit need to meet Turtle Code: NO
Glass Family: ating
Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN
Interlayer Type: PVB090
Argon Gas: NONE
Glass Color: CLEAR
Low E: ENERGY SHIELD MAX
Privacy Glass: NONE
Glass Spacer Type: TB
Grid Type: NO Grid
i Screen Type:1816 Charcoal
Screen Frame Type: ROLLFORM
Anchor Group: D.SH5500
Boxing Options: None
Vent Latch: N
Comfort Lift: Y
Lift Rail: N
WOCD: N
Lock Type: Sweep Latch
Reinf. Upgrade. None
Acc Glass Breakage: N
Vent Ht: 30.6430
CAR#:16-0714.03
PositiveDesignPressure: 50.0000
NegativeDesignPressure: 50.0000
PANumber: FL-239
EnergyStar:1.0000
CondensationResistance: 65.0000
UF: 0.3200
SolarHeatGainCoeff: 0.2200
VT: 0.4800
VTCOG: 0.6300
Location:
0001 , SH5500 VINYL SINGLE HUNG 5500 Ordered: List Price' Sell Price E)t Price
(3.00) MULL EXT/INT COVERS & CLIP SET,.,36.X62.X.,STD,5/8" 1.00 $795.90 $0.00 $0.00
FL,W,EQUAL,7/8 LIG,CL,SB 70XL,NO
GRID,SWEEP,1816K,CMFRT LFT HNDL,.x.
Quote # 632210
Print Date
1 /24/2017
Page 1 of 7
Certification Type: MIAMI
NOA Selection: 16-0714.03 I
Frame Type:.625FLANGE
Vent Configuration: EQUAL
Window Style: STD
Size Selection: CUSTOM
Size Ref: ACTUAL
Actual Size: 36 X 62
Rough Masonry: 37 314 X 63
Wood Frame: 36 1/4 X 621 /4
Egress: 31 314 X 26 3/8 (5.808 SQFT)
Frame Color: White
Does unit need to meet Turtle Code: NO
Glass Family: ating
Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN
Interlayer Type: PVB090
Argon Gas: NONE
Glass Color: CLEAR
Low E: ENERGY SHIELD MAX
Privacy Glass: NONE
Glass Spacer Type: TB
Grid Type: NO Grid
Screen Type:1816 Charcoal
Screen Frame Type: ROLLFORM
Anchor Group: D.SH5500
Boxing Options: None
Vent Latch: N
Comfort Lift: Y
Lift Rail: N
WOCD: N
Lock Type: Sweep Latch
Reinf. Upgrade: None
Acc Glass Breakage: N
Vent Ht: 30.6430
CAR#:16-0714.03
PositiveDesignPressure: 50.0000
NegativeDesignPressure: 50.0000
PANumber: FL-239
EnergyStar: 1.0000
Condensation Resistance: 55.0000
UF: 0.3200
SolarHeatGainCoeff: 0.2200
VT: 0.4800
VTCOG: 0.6300
Location:
0001
MULL MULL BARS
Ordered:
List Price
Sell Price
Ext Price
(4,00)
,62.,WHITE,.625FLANGE,SERIES
1.00
$269.96
$0.00
$0.00
L,
5500,FCTRML,MULUCVR/CLPS
Product Family Series: 5500.0000
Certification Type: MIAMI
NOA Selection: 16-0218.03
Part Selection: MULL/CVR/CLPS
Frame Type:.625FLANGE
Mull Bar Type: 1.25X3.25X.625
Mull Clip Type: T-CLIPIT-CLIP
Size Selection: CUSTOM
Frame Color: W
Assembly Options: FCTRML
Packaging Options: N
END MODEL SET 001:
Location:
0002
SH5500 VINYL SINGLE HUNG 5500
Ordered:
List Price
Sell Price
Ext Price
(5.00)
...25.5X49.625X.,H34,STD,5/8" FL,W,EQUAL,7/8
2.00
$514.90
$285.06
$570.12
LIG,CL,SB 70XL,NO GRID,SWEEP,1816K,CMFRT LFT
HNDL,.x.
yy i
{
Certification Type: MIAMI
Frame Type:.625FLANGE
NOA Selection: 16-0714.03
Vent Configuration: EQUAL
fi
!1
Window Style: STD
Size Selection: COMMODITY
! i
Size Code: H34
Actual Size: 25 1/2 X 49 5/8
Size Ref: ACTUAL
Rough Masonry: 271/4 X 50 5/8
{ j
Wood Frame: 25 314 X 49 7/8
Egress: 21 1/4 X 20 1/8 (2.974 SQFT)
Frame Color: White
Does unit need to meet Turtle Code: NO
Glass Family: Laminated Insulating
Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5116 AN/AN
intedayer Type: PVB090
Argon Gas: NONE
Glass Color: CLEAR
Low E: ENERGY SHIELD MAX
Privacy Glass: NONE
Glass Spacer Type: TB
Grid Type: NO Grid
Screen Type: 1816 Charcoal
Screen Frame Type: ROLLFORM
Anchor Group: D.SH5500
Boxing Options: None
Vent Latch: N
Comfort Lift: Y
Lift Rail: N
WOCD: N
Lock Type: Sweep Latch
Reinf. Upgrade: None
Acc Glass Breakage: N
Vent Ht: 24.4550
CAR#: 16-0714.03
PositiveDesignPressure: 50.0000
NegativeDesignPressure: 50.0000
PANumber: FL-239
EnergyStar: 1.0000
CondensationResistance: 55.0000
UF: 0.3200
SolarHeatGainCoeff: 0.2200
VT: 0.4800
VTCOG: 0.6300
Location:
Quote # 632210
Print Date 1/24/2017
Page 2 of 7
0003
SH5500 VINYL SINGLE HUNG 5500
Ordered:
List Price Sell Price
Ext Price
(6.00)
36.X37.375X.,23,STD,518" FL,W,EQUAL,7/8 LIG,CL,SB
1.00
$543.90 $301.11
$301.11
70XL,NO GRID,SWEEP,1816K,CMFRT LFT HNDL,.x.
l
•
Certification Type: MIAMI
NOA Selection:16-0714.03
Frame Type:.625FLANGE
Vent Configuration: EQUAL
Window Style: STD
Size Selection: COMMODITY
u
'
Size Code: 23.0000
Actual Size: 36 X 37 3/8
Size Ref: ACTUAL
Rough Masonry: 37 3/4 X 38 3/8
L J
Wood Frame: 36 1/4 X 37 5/8
Egress: 31 3/4 X 14 0/1 (3.094 SQFT)
Frame Color: White
Does unit need to meet Turtle Code: NO
Glass Family: Laminated Insulating
Glass: 7/8" L1G (1/8 AN - 7/16 AIR -5/16 AN/AN
Interlayer Type: PVB090
Argon Gas: NONE
Glass Color: CLEAR
Low E: ENERGY SHIELD MAX
Privacy Glass: NONE
Glass Spacer Type: TB
Grid Type: NO Grid
Screen Type: 1816 Charcoal
Screen Frame Type: ROLLFORM
Anchor Group: D.SH5500
Boxing Options: None
Vent Latch: N
Comfort Lift: Y
lift Rail: N
WOCD: N
Lock Type: Sweep Latch
Reinf. Upgrade: None
Acc Glass Breakage: N
Vent Ht: 18.3300
CAR#: 16-0714.03
PoshiveDesignPressure: 50.0000
NegativeDesignPressure: 50.0000
PANumber. FL-239
EnergyStar: 1.0000
CondensationResistance: 55.0000
UF: 0.3200
SolarHeatGainCoeff: 0.2200
VT: 0.4800
VTCOG: 0.6300
Location:
- i
0004 MULTI -PART MULTI -PART UNITS Ordered: V List Price Sell Price r JExt Price
(7.00) 110.5X37.375X.,5500,TR,MTCH 1.00 $0.00 i $1,027.59 $1,027.59
I
COL,W,.625FLANGE,EQUAL
i
BEGIN MODEL SET 007::
Series: 5500.0000
Combination Configuration: TR
Unit 1 (Bottom Left Unit): SH5500
Unit 2: SH5500
Continuous Shape Multi -Part: N
Unit 3: SH5500
Frame Type:.625FLANGE
Assembly Options: MTCHCOL
Width Equal or Width: EQUAL
Send Mull(s): Y
Mull Part Selection: MULUCVR/CLPS
Size Slection: ACTUAL
Width: 110.5000
Height: 37.3750
Vertical Mull: 1.25X3.25X.625
Vertical Mull (2): 1.25X3.25X.625
Frame Color: White
Glass Color: CL
Boxing Options: N
Location:
0004 SH5500 VINYL SINGLE HUNG 5500 Ordered: j Lfst Price I Sell Price Ext Price
(6.00) MULL EXTANT COVERS & CLIP 1.00 $543.90 1 $0.00 $0.00
SET,.,36.X37.375X.,STD,5/8" FL,W,EQUAL,7/8 LIG,CL,SB
70XL,NO GRID,SWEEP,1816K,CMFRT LFT HNDL,.x.
Quote # 632210
Print Date 1/24/2017
Page 3 of 7
Certification Type: MIAMI
NOA Selection: 16-0714.03
Frame Type:.625FLANGE
Vent Configuration: EQUAL
Window Style: STD
Size Selection: CUSTOM
Size Ref: ACTUAL
Actual Size: 36 X 37 3/8
Rough Masonry: 37 314 X 38 3/8
Wood Frame: 361/4 X 37 5/8
Egress: 31 3/4 X 14 0/1 (3.094 SOFT)
Frame Color: White
Does unit need to meet Turtle Code: NO
Glass Family: ating
Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN
Interlayer Type: PVB090
Argon Gas: NONE
Glass Color: CLEAR
Low E: ENERGY SHIELD MAX
Privacy Glass: NONE
Glass Spacer Type: TB
Grid Type: NO Grid
Screen Type:1816 Charcoal
Screen Frame Type: ROLLFORM
Anchor Group: D.SH5500
Boxing Options: None
Vent Latch: N
Comfort Lift: Y
Lift Rail: N
WOCD: N
Lock Type: Sweep Latch
Reinf. Upgrade: None
Ace Glass Breakage: N
Vent Ht:18.3300
CAR#:16-0714.03
PositiveDesignPressure: 50.0000
NegativeDesignPressure: 50.0000
PANumber: FL-239
EnergyStar:1,0000
Condensation Resistance: 55.0000
UF: 0.3200
SolarHeatGainCoeff: 0.2200
VT: 0.4800
VTCOG: 0.6300
Location:
0004
SH5500 VINYL SINGLE HUNG 5500
Ordered:
List Price
Sell Price
Fact Price
(9.00)
MULL EXTANT COVERS & CLIP
1.00
$543.90
$0.00
$0.00
SET,.,36.X37.375X.,STD,5/8" FL,W,EQUAL,7/8 LIG,CL,SB
70XL,NO GRID,SWEEP,1816K,CMFRT LFT HNDL,.x.
Certification Type: MIAMI
NOA Selection: 16-0714.03
Frame Type:.625FLANGE
Vent Configuration: EQUAL
•
Window Style: STD
Size Selection: CUSTOM
Size Ref: ACTUAL
Actual Size: 36 X 37 318
Rough Masonry: 37 3/4 X 38 3/8
Wood Frame: 361/4 X 37 518
Egress: 31 3/4 X 14 0/1 (3.094 SOFT)
Frame Color: White
Does unit need to meet Turtle Code: NO
Glass Family: ating I
Glass: 718" LIG (1/8 AN - 7/16 AIR -5/16 AWAN
Interlayer Type: PVB090
Argon Gas: NONE
Glass Color: CLEAR
Low E: ENERGY SHIELD MAX
Privacy Glass: NONE
Glass Spacer Type: TB
Grid Type: NO Grid
Screen Type: 1816 Charcoal
Screen Frame Type: ROLLFORM
Anchor Group: D.SH5500
j Boxing Options: None
Vent Latch: N
Comfort Lift: Y
Lift Rail: N
WOCD: N
Lock Type: Sweep Latch
Reinf. Upgrade: None
Ace Glass Breakage: N
Vent Ht: 18.3300
CAR#:16-0714.03
PositiveDesignPressure: 50.0000
NegativeDesignPressure: 50.0000
PANumber: FL-239
EnergyStar:1.0000
CondensationResistance: 55.0000
UF: 0.3200
SolarHeatGainCoefi: 0.2200
VT: 0.4800
VTCOG: 0.6300
Location:
0004 SH5500 VINYL SINGLE HUNG 5500 ~ Ordered: List Price Sell Price E)d Price
(10.00) MULL EXT/INT COVERS & CLIP 1.00 $543.90 $0.00 $0.00
SET,.,36.X37.375X.,STD,5/8" FL,W,EQUAL,7/8 LIG,CL,SB
70Xt NO GRID,SWEEP,1816K,CMFRT LFT HNDL,.x.
Quote # 632210
Print Date 1/24/2017
Page 4 of 7
Certification Type: MIAMI
NOA Selection: 16-0714.03
Frame Type:.625FLANGE
Vent Configuration: EQUAL
Window Style: STD
Size Selection: CUSTOM
•
Size Ref: ACTUAL
Actual Size: 36 X 37 3/8
Rough Masonry: 37 3/4 X 38 3/8
Wood Frame: 36 1/4 X 37 518
Egress: 31 3/4 X 14 0/1 (3.094 SQFT)
Frame Color: White
Does unit need to meet Turtle Code: NO
Glass Family: ating
•
Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN
Interlayer Type: PVB090
Argon Gas: NONE
Glass Color: CLEAR
Low E: ENERGY SHIELD MAX
Privacy Glass: NONE
Glass Spacer Type: TB
Grid Type: NO Grid
Screen Type: 1816 Charcoal
Screen Frame Type: ROLLFORM
Anchor Group: D.SH5500
Boxing Options: None
Vent Latch: N
Comfort Lift: Y
Lift Rail: N
WOCD: N
Lock Type: Sweep Latch
Reinf. Upgrade: None
Acc Glass Breakage: N
Vent Ht: 18.3300
CAR#:16-0714.03
PositiveDesignPressure: 50.0000
NegativeDesignPressure: 50.0000
PANumber: FL-239
EnergyStar:1.0000
Condensation Resistance: 55.0000
UF: 0.3200
SolarHeatGainCoeff: 0.2200
VT: 0.4800
VTCOG: 0.6300
Location:
0004
MULL MULL BARS
Ordered:
List Price
Sell Price
Ext Price
(11.00)
1 ,37.375,WHITE,.625FLANGE,SERIES
1.00
$96.42
$0.00
$0.00
5500,MTCHCOL,MULUCVR/CLPS
Product Family Series: 5500.0000
Certification Type: MIAMI
NOA Selection: 16-0218.03
Part Selection: MULUCVR/CLPS
Frame Type:.625FLANGE
Mull Bar Type: 1.25X3.25X.625
•
Mull Clip Type: T-CLIP/T-CLIP
Size Selection: CUSTOM
Frame Color: W
Assembly Options: MTCHCOL
Packaging Options: N
Location:
0004
Ordered:
List Price
Sell Price
Ext Price
(12.00)
IMULLMULLBARS
,37.375,WHITE,.625FLANGE,SERIES
�1.00
$96.42
$0.00
$0.00
5500, MTCHCOL, M ULUCVR/CLPS
Product Family Series: 5500.0000
Certification Type: MIAMI
NOA Selection: 16-0218.03
Part Selection: MULUCVR/CLPS
Frame Type:.625FLANGE
Mull Bar Type: 1.25X3.25X.625
Mull Clip Type: T-CLIP/T-CLIP
Size Selection: CUSTOM
Frame Color: W
Assembly Options: MTCHCOL
Packaging Options: N
END MODEL SET 007:
I Location:
0005 PW5520 VINYL PICTURE WINDOW Ordered: List Price Sell Price Ext Price
IPW5520
60.X14.,5/8" FL,W,7/8 LIG,CL,SB 70XL,OUTSIDE 1.00 $668.00 $361.21 $361.21
`(13.00)
GLZ,NO GRID,.x.
Quote # 632210
Print Date 1/24/2017
Page 5 of 7
Certification Type: MIAMI
NOA Selection: 16-0629.12
Frame Type:.625FLANGE
Size Selection: CUSTOM
Size Ref: ACTUAL
Height: 14.0000
Rough Masonry Opening: 61 314 X 15
Width: 60.0000
Actual Size: 60 X 14
Wood Frame Opening: 60 1/4 X 14 1/4
-
Frame Color: White
Does unit need to meet Turtle Code: NO
Glass Family: Laminated Insulating
Interlayer Type: PVB090
Argon Gas: NONE
Glass: 7/8" LIG (1/8 AN - 7116 AIR -5/16 AN/AN
Glass Color: CLEAR
Low E: ENERGY SHIELD MAX
Privacy Glass: NONE
Glass Spacer Type: SS
I
Grid Type: NO Grid
Boxing Options: None
Acc Glass Breakage: N
CAR#: 16-0629.12
PositiveDesignPressure: 50.0000
NegativeDesignPressure: 50.0000
PANumber: FL 243
I EnergyStar: 123.0000
CondensationResistance: 58.0000
UF: 0.2800
SolarHeatGainCoeff: 0.2300
VT: 0.5300
VTCOG: 0.6300
Location:
0006 AR5520 VINYL ARCHITECTURAL 5520 Ordered: List Price SeJI Price Fact Price
(14.00) ,74.125X16.X6.X.,51&' FL,W,EB,7/8 LIG,CI SB 1.00 $1,416.00 $756.50 $756.50
170XI,OUTSIDE
GLZ,NO GRID,SUPERSPACER,.,.x.
Certification Type: MIAMI
NOA Selection:16-0629.12
-
Shape: EB
Drop: 10.0000
Frame Type:.625FLANGE
Size Selection: CUSTOM
Size Ref: ACTUAL
Width: 74.1250
Height: 16.0000
Leg Height: 6.0000
Actual Size: 741/8 X 16 X 6
Rough Masonry Opening: 75 7/8 X 17 X 7
Wood Frame Opening: 74 3/8 X 161/4 X 61/4
Frame Color: White
Does unit need to meet Turtle Code: NO
Glass Family: Laminated Insulating
Glass Type: 10 - 5/16"
Interlayer Type: PVB090
Argon Gas: NONE
Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5116 AN/AN
Glass Color: CLEAR
Low E: ENERGY SHIELD MAX
Glass Spacer Type: SS
Grid Type: NO Grid
Colonial Color: W
Boxing Options: None
Acc Glass Breakage: N
Privacy Glass: NONE
CAR#: 16-0629.12
PositiveDesignPressure: 50.0000
NegativeDesignPressure: 50.0000
PANumber: FL 243
EnergyStar: 123.0000
CondensationResistance: 58.0000
UF: 0.2800
SolarHeatGainCoeff: 0.2300
VT: 0.5300
VTCOG: 0.6300 l
Location:
0007 AR5520 VINYL ARCHITECTURAL 5520 Ordered: List Price Sell Price Ext Price
(15.00) 24.X24.X.X.,5/&' FL,W,OC,7/8 LIG,CL,SB 70XL,OUTSIDE 2.00 $826.00 $441.29 $882.58
GLZ,NO GRID,EQUAL,SUPERSPACER,.,.x.
Certification Type: MIAMI
NOA Selection: 16-0629.12
Shape: OC
Shape Orientation: EQUAL
Frame Type:.625FLANGE
Size Selection: CUSTOM
Size Ref: ACTUAL
Width: 24.0000
Actual Size: 24 X 24
Rough Masonry Opening: 25 314 X 25
Wood Frame Opening: 24 1/4 X 24 114
Frame Color: White
Does unit need to meet Turtle Code: NO
Glass Family: Laminated Insulating
Glass Type: 10 - 5/16"
Interlayer Type: PVB090
Argon Gas: NONE
Glass: 7/8" LIG (1 /8 AN - 7/16 AIR -5/16 AN/AN
Glass Color: CLEAR
Low E: ENERGY SHIELD MAX
Glass Spacer Type: SS
Grid Type: NO Grid
Colonial Color: W
Boxing Options: None
Acc Glass Breakage: N
Privacy Glass: NONE
CAR#:16-0629.12
PositiveDesignPressure: 50.0000 f
NegativeDesignPressure: 50.0000
PANumber: FL 243
EnergyStar: 123,0000
Condensation Resistance: 58.0000
UF: 0.2800
SolarHeatGainCoeff: 0.2300
i
VT: 0.5300
VTCOG: 0.6300
Location: 1
Quote # 632210
Print Date 1/24/2017
Page 6of7
•
0008 SGD5570 VINYL SGD SERIES 5570 Ordered: List Price Sell Price Ext Price_
(16.00) ,.,143.X80.,12068,BYPASS,4P2T,OXXO,STD,2.5,W,11/16 1,00 $6,025.00 $3,575.84 $3.576.84
TLIG,CLEAR,SB 70XL,NO GRID,BS,1816K,ALL,.x.
Send Unit: COMPLETE
Certification Type: MIAMI
NOA Selection: 15-1210.01
Door Configuration: BYPASS
PnVTrk: 4 Panel / 2 Track
Panel Configuration: OXXO
Panel Stack: STD
Size Selection: NOMINAL
Size Code:12068.0000
Actual Size:143 X 80
Calc Track Length: 143.0000
Frame Color: White
Sill Riser Height: 2.5000
Does unit need to meet Turtle Code: NO
Glass Family: Laminated Insulating
Interlayer Type: PVB090
Argon Gas: NONE
Glass: 1-1/16" LIG (3/16 TMP-7/16AIR-7/16 AN/HS
Glass Color: CLEAR
Low E: ENERGY SHIELD MAX
Privacy Glass: NONE
Glass Spacer Type: TB
Grid Type: NO Grid
Screen Panel Type: BOX
Screen Rail Qty:1-BOX
Screen Mesh Type:1816 Charcoal
Panel Opr Rlr: Steel Tandem
Panel Fxd Rlr: Steel Tandem
Screen Rlr: Steel
Acc Glass Breakage: N
Handle Type: RAISED/RAISED
Handle Color: W
Lock/Handle Location: STD
Secondary Lock Type: NONE
Key Lock: N
Keyed Alike: N
Anchor Group: D.SGD5570
Boxing Options: None
Add Panel Reinf.: N
Send frm w/snap on Nail Fin: N
CAR#:15-1210.01
PositiveDesignPressure: 38.7000
NegativeDesignPressure: 60.0000
PANumber: FL-251
EnergyStar: NONE
Condensation Resistance: 56.0000
UF: 0.3500
SolarHeatGainCoeff: 0.2000
VT: 0.4200
VTCOG: 0.6200
Location:
TOTAL AMT:
$8,530.16
I
TOTAL TAX:
$511.81
NET AMOUNT:
$9,041.97