HomeMy WebLinkAboutFBC ENERGY CONSERVATIONCODE 4-18-18j
Planning & Development Services; Building & Code Regulation Division
2300 Virginia Ave, Rm 201; Fort Pierce, FL 34982
772-462-2165 Fax 772-462-6443
FBC ENERGY CONSERVATION CODE R402.4.1.V RECEIVED
House Infiltration Test (Blower Door) Certificai
Prescriptive and Performance Method
Date: 172-0c o Permit #: 17c)(o o ZL
Contractor:
Job Address: 4���ro ��BL``ST��� �(zi I
Construction:
APR 18 2018
Lucie County, Permitting
Construction — Complete ( ) Existing —After Addition
House Infiltration Tes a Its SLC Climate Zone 2
CFM (50) = Test Date: O Li ( 17 ��I
Z717Volume =
ACH (50) = CFM (50)x 60 / Volume = Mec ical Ventilation required less than 3 ACH
Passing results must be &ACH (50) or less ( Pass ( )Fail
FBC, Energy
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting
shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105
(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party
conducting the test and provided to the code official. Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
FBC, Residential
R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when
tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida
Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in
accordance with Section M1507.3.
pe Company SComan Name: Address:yO
I hereby certi at the above House -Infiltration results demonstrate compliance with FBC Energy Conservation
requirem is iWcZ9r4aryce with S ion R402.4.1.2 Climate Zone 2.
Signatu
Printed Name:
License/Certification #: