Loading...
HomeMy WebLinkAbout30 DAY TEMPORARY POWER RELEASERECEIVED JUN 0 e 7017 Planning Si Development Services Building & Code Regulation Division 2306 Virginia :Ave Fort Pierce, K 34982- 772-462-2I65 Fau 772-462-6443 Request for 30-Day Temporary power Release Date: 6/7/2017 ------------ Permit Number: Project Address: 8465 Cobblestone DR THE UNDERSIGNED HEREBY REQUEST RELEASE OF ELE� - . . PROPERTY, FOR A PERIOD NOT TO EXCEED TFIIRTY (30) DAYS, FOR THE PURPOSE OF CTRICAL. POWER TO THE ABOVE DESCRIBED ?AND EQUIPMENT IN PREPARATION FORA FINAL INSPECTION, IN CONSIDERATION O REQUEST WE HEREBY ACKNOWLEDGE: AND AGREE AS FOLLOWS: TESTING SYSTEMS F APPROVAL OF THE 1. This temporary power release is requested for the above stated purpose only, and there will b occupanry of any type, other than that Z. !n witness by our signatures, we hereby agree to abide by all ermsuand conditions of thls a e no lnciuding Building Division Policy; which is Incorporated herein during this time period. 3. All conditions and requirements 'listed in the attached document entitled "Requirements for agreement, by reference. Power for Testlng^ have been fulfilled and the premise Is ready for Compliance inspection, 4. All requests for an extension beyond 30 days30 Day the reason for the request• power may be removed from the site and/or a stop Wofk Order Issued if must be made to writing to the Building OfFictal staling the Final Inspection has not been approved within 30 days• A fee of $100.00 will be required to lift WE HEREBY RELEASE AND AGREE TO HOLD HARMLESS, ST. LUCIE COUNTY ALL HIS - -177ES AND CLAIMS OF ANY TYPE OF NATURE WHICH MAY ARISE NOW O OF THIS TRANSACTION INCLUDING ANY DAMAGE WHICH MAY INCURRED w THEIR EMPLOYEES FROM DISCONNECTION OF ELECTRICALR IN THE FUTURE OUT POWER IN THE EVENT OF VIOLATION OF E TO THE THIS AGREEMENT. 6/7/2017 DATE CONTRA SIGNATURE 6/7/2017 ` DATE AL CONTRACTOR SIGNATURE 6/7/2017 DATE: RE:CEI�'�D JUN 010 7017 St. Lucie County Building.and Zoning Department Requirements for.30 Day Power for Testing " ! Form entitled Request for 30-Da Y Temporary Power Release" must be fully exe the Building. Department record. files prior to inspectioncuted and posted in ll. Inspection Requirements: 1, Address numbers shall be posted per county Ord. No. 7.05.09. 2. till entrances, exits, windowsand garage doors. must be lockable. 3. All circuits on exterior shall be terminated in a box with weatherproof cover. to a disconnect. If circuits are at or. above 7'6" from The same applies and taped. grade they may be capped with wire nuts 4. All breakers niust be installed. Any blank space must be closed b a bra plates. Y break or approved filler 5. Interior Wiring; Al! receptacles, light fixtures and fans must be trimmed ` 7'6" from the flooi or mezzanine that is notavailable at the time Any fixture below Inviso.Plate installed. Fixtures at or above that height. me of inspection must have an 8 may be capped with wire nu 6. A!1 smoke detectorsts and taped. .must be installed. 9. Kitchen cabinets m hust be installed; any exception for special conditions or circu ave.an approval prior to scheduled inspection, mstances must 8. Sewer and water connections must be complete. Only well Pumps are requirement:..excluded from this 9. Exterior construction must be complete and weather tight, includin stu softit. g cco, siding, roof and 10. Penn it work shall be substantially completed except for backorders and/or 0cor covering, pumps, air conditioners and drivewa. 'Paint on exterior, carpet y