Field Density Tests of Compacted Soils Method D-6938
Project: Proposed Residence Lot. 82, Creekside
Date:
July 26, 2017
Address: 8465 Cobblestone, Drive, Fort Pierce, FL 34945
Order #:
17-DR-768
Area Tested: Building Pad
Permit #:
D(k - 62-3 3
Material Type: Pale Brown Sand
Tech:.
BK
Client: D.R. Horton, Inc.
Address: 1430 Culver Drive NE Compaction Req.: 95%
Palm Bay, FL 32907 Proctor Method: ASTM D-1557
Test
#
TEST LOCATION
Probe
Depth
Elev.
Moist
%
Dry
Density
PCF
Proctor
Value
PCF
Optimum
Moisture
/o
Compaction
Pass
1
Center of Pad
12"
FL
8.2
104.0
105.3
14.0
98.8%
Yes
2
SE Corner of Pad
12"
FL
8.0
1012,
105.3
14.0
98.0%
Yes
3
NW Corner of Pad
12"
FL
9.5
104.8
105.3
14.0
99.5%
Yes
4
5
6
7
8
9
10
11
12
13
14
Remarks: See Reverse Side (Page 2 of 2) for Additional Information for Disclaimer
This is a Compaction Test only on the top 12" of the pad and is not a verification of Soil BAarino'Capacity.
Legend for Elevation:
PR = Proofroll 1,2,3 = 1st, 2nd, 3rd Lift Submitted by:
SL = Springline FL =Final Lift KeitO.'eBlzinb�;-P,E, 7,r� (,
SG = Subgrade BG = Below Grade FILE
Federal Erlgirieering & Testing, Inc.
BC = Basecourse BOF = Bottom of Footing Florida Reg"Igo. 59394 -
CoPY
_
TOP -Top of Pipe FG - Finished Grade Certificate of Authorization #5471
As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and,authorization for publication of statements,
conclusions or extracts from or regarding our. reports is reserved pending our written approval. A density test determines th6;de6rse of compaction of the, tested layer of
material only. A density does not replace a soil bearing capacity determination. These density tests do not certify the underlying`soil`mate�iais below the proposed structure.
The results do not preclude or guarantee that future settlement and cracking will not occur. A soil boring test is required to certify'that#f :e gdermng soils will support the
proposed structure without settlement. If no soil borings have been performed to verify the underlying soils, we recommend that soil borings be performed to evaluate the
suitability of the underlying soil to support the proposed structure. After laying dormant for a period of 90 days or after heavy rain/storms, retesting must be performed on this
work.
W PAGE 1 of 2
Compacted;Soils
Pursuant to your request, Federal Engineerirg`&'Te;
project on the reverse side. The purpos' of our tes
11
material only. In no way shall a compaction test °replcl
performed by the client prior to dbnstruction to'Verify s
12" of added fill material,., FET, was not,contracted tc
the added fill material does .not..include-an.'analysis
supporting the proposed structure without settlement.
materials or conditions below the tested top 12 inches
the proposed structure, we recommend performing
verify the underlying soil conditions.
Method D-6938 Disclaimer
ing, Inc. (FET) has performed a compaction test at the referenced
was to determine the degree of compaction of the tested layer of
;e a soil bearing capacity determination. A soil boring test must be
bsoil conditions. Our scope of services only included testing the top
perform supervision of the building pad preparation. This testing of
if the underlying soil materials to determine if they are capable of
This density compaction test does not warranty any underlying soil
)f material. If no soil borings have been performed in the location of
iil borings below all foundation areas of the proposed structure to
Environmental analysis of the soil materials is not partM the scope of services. If environmental analysis of the soils is
required, we can provide a proposal for performing an environmental analysis of the soil materials. The scope of services is
for determination of the degree of compaction of the tested layer of material only. No other analysis is implied or warranted.
Job project specifications were not available at the time t l� e work was performed. Determination of the pass/fail compaction
results are based on current common industry requirements of 95% of the ASTM D-1557 standard for building foundations
and 98% of the AASHTO T-180 standard for paved areas such as roadways and parking lots. If different specifications are
required, Federal Engineering & Testing, Inc. shall be notified.
Our findings are relative to the date and areas of our site work and should not be relied upon to represent conditions on
other areas or dates. Any subsequent site disturbances due to water erosion, rain waters, construction activities,
excavations, overgrown, vegetation, traffic and other disturbances will void this test and the site must be re -compacted and
re -tested prior to construction. I
As a mutual protection to clients, the public and ourselves,lall reports are submitted are the confidential property of clients
and authorization for use, publication of statements, conclusions or extracts from or regarding our reports is reserved
pending written approval. I
It has been a pleasure working with you and we look forward�to doing so in the near future.