HomeMy WebLinkAboutREVISIONA k C H I T E C T S
=�t
0"
3 11
----------
I
fo"Xro" P.T. POST I
(2 TYP.)
LANAI I
I I
I10'=211
r0068 S.G.D.—�
DINING I =
ROOM
I
I
I
3�1=gll
(2) 3052-SH
LIVING
ROOM
8' -8' CLG. o�
2-1'-011
3'-511 T _1011
4x4 `r
POS�
cl ( REFI _b36
3 - SHC-
ARCC: -4 V-
all
8 II
4'-011
I
II =
B
FLEX
I a
FOYER
S'-8" CLG.
_ L"
8'-8" CLG.
B
j
10m TRANS.
W/C"I V'
3068
10 TRANS.
(2) 3052 - 5H
=
MT.
51-411
COND.
3052 - 5H
EGRESS
21=gll
BEDROOM #2r
CLG. -'
31
_411 eI_011
IR-15H �"
I Ir
I� C
I I BATH #9-
I ' - 8" CLG. in
G. Y. =3 �N
co
LAV.
1 �j 1I
`7 a)
1 • ,!i o r--`---,
L.P.w.
WALL W/ GAP WH.
STOR.
SLOPED CLG.
STAIR DATA
Wo RISERS tv 1.54"
15 TREADS 0 10"
+1" NOSING
BOLLARD
21'-4" AS REQ.
PER BLDG.
CODE
GARAGE
CLG.
1G'-0" 2'-10
11_0II
121-1011
BLK. COL. TO PORCH
8 8 CLCs.
(3 TYP.)
■
21'-811
16'-0"xrt'-0°o.HD.
0 10 • -------
--------------
i'-4° 10'-011 I -4
20'=411
39' - 811
EXTERIOR MASONRY
WALL BRG. HEIGHTS
r
8'-8" BRCx.
LOAD BRG. WALL
UN-O. ON PLAN5
SQ.FT.
CALC.'S
IST FLR LIVING
1104
50. FT.
2ND 1=LR LIVING
1501
5Q. PT.
TOTAL LIVING
26,05
SQ. FT.
GARAGE
43-T
SQ. FT.
PORCP
III
SQ. PT.
COVERED LANAI
80
5Q. Ft.
TOTAL
3233
50, FT,
VOLUME
216"31.2 CU FT
SEfSMIC
SUBJECT TO DAMAGE FROM
WINTER
ICE BARRIER
UNDERTLAYMI=NT
FLOOD
HAZARDS
AIR
1=REEZINCx
MEAN
ANUA
GROUND
WIND DESIGN
SNOW
SPEED
TOPOGRAPHIC
pE51CsN
WEATHERING°
FRO5T LINE
TERMITEG
DESIGN
TEMP'
REQUIRED"
INDEX
i
TEMP.
LOAD
(MPH)
EFFECTSk
CATAGORY`
DEPTHb
kin
NJ�rtl IrtARI
Nd
VERY HEAVY
42
NA
SEE SURVEY
NA
NA
FLAME SPREAD AND SMOKE INDEX FOR WALL AND CEILING FINISHES SHALL BE IN
ACCORDANCE WITH SECTION 1=BC R302.S.1 THROUGH EBC R302,S.4
FLAME SPREAD AND SMOKE -DEVELOPED INDEX FOR INSULATION SHALL BE IN
ACCORDANCE WITH SECTION 1=5C R302.10.1 THROUC%H 1=5C R302.10.5
COMPONENT AND CLADDING WIN] LOADS
BASIC WIN] EX*OSURE FOR 3 SECOND GUSTS
OPENNGS
SQUARE
ZONE
160 WH WIND (M)
REAL CS
AND TYPE
FOOTAGE
MIN. WINDOW
10
5
34/_45
CRITERIA
EXTERIOR SWING
1s
5
33/-43
DR. MIN. CRITERIA
S.G.D. MIN.
41
5
31/-39
CRITERIA
lro0l0 O.H.D_
112
5
29/-35
BASIC WIND SPEED MPH = 160 (Volt) INTERNAL
PRESSURE COEFFICENT = f 0.18 BLDG. CAT.=II,
EXP.=C, MEAN ROOF HT. = 23'-0"
PRESSURES HAVE BEEN MODIFIED PER SECTION 612.2 OF
THE FBCR 5th EDITION (2014) TO MEET TESTED ALLOWABLE
OR NOMINAL WIND LOAD VALUES FROM THE PRODUCT
MANUFACTURER. CONTROL DATE 07/08/15
co
FIRST FLOOR PLAN
NOTE:
-2-8 LOUV. DOOR W/ AIR HANDLER ON METAL STAND OR 2-8 SOLID
DOOR W/ RETURN PLENUM AND RETURN AIR GRILLE.
- VERIF r CONDENSER PAD LOCATION WITH SITE PLAN.
- FRONT DOOR A55EM5L1` TO BE THERMA-TRU F15ERGLA55 DOOR W/
TRANSOM (SINGLE A55EM5LY)
-20 MIN. FIRE RATED DOOR TO BE EQUIPPI=D W/ SELF -CLOSING DEVICE
PER SECTION R302.5.1 01= THE FBCR 5TH EDITION (2014)
6
11 4 11
DEB
TOP
PLATE
A BAR DETAIL
SCALE: 1/2" =1' -0"
ARCH
a
:F'S MA77ACk
OFRECORD
MENTS
rHE
RECORD
ARCH
C
ARE S0 PLANS A
RE Ug�ECr 4 ALL P
�AQ13SNF RYFECD�NYSpoRRECrj.jVS h
-OMPt"W/ HAL4RYpN 0� ,q 7Q rhAr
E
1 JFI
JrT. t_i.iCf� county Permitting
esi n
{..;r ou Inc.
1441 N. RONALD REAGAN BLVD.
LONGWOOD, FL 32750
PH: 407-774-6078
FAX: 407-774-4078
www.abdesigngroup.com
AA #: 0003325
.4
w
o
c�
cA
w
o
O
O
g
h
r
�
A
0
r
�
n
5tT39DM Sa Loyr.
CREEKSIDE
LOT #82
PROJIECT#
04321.000
MODIEU
4EHB
"2605—HAYDEN"
GARAGE S'wING:
RIGHT
PAGIL
FIRST
FLOOR
PLAN
160 MPH EXP. C
w MELBOURNE
ARCHITECT:
7' r A T� OF FLORIDA
k'
Cot ol
JAMES C LL
1 079
DAT� 04/03/17
SCAB: 1/4
I ;low
LLv