Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEe , FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: DAVENPORT RESIDENCE Builder Name: Street: LOT #35 OCEAN RESORT Permit Office: City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Owner: Jurisdiction: • Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Walt Types.(1537.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1537.80 ft2 3. Number of units, if multiple family 1 b. N/A c. NIA R= ft2 R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (956.0 sqft.) Insulation Area a. Under Attic (Vented) R=19.0 956.00 ft2 6. Conditioned floor area above grade (ft2) 956 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(219.5 sqft,) Description Area 11. Ducts R ft2 a. Sup: Exterior, Ret: Exterior, AH: Exterior 6 175 a. U-Factor: Dbl, U=0.29 130.50 ftz SHGC: SHGC=0.21 b. U-Factor:. Dbl, U=0.30 80.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 28,6 SEER:15.50 c. U-Factor: Dbl, U=0.29 9.00 ft2 SHGC: SHGC=0.21 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: !' Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.225 14. Hot water systems 6. Floor Types (955.5 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Raised Floor R=19,0 955.50 ft2 b. Conservation features EF: 0.970 b. NIA R= ft2 ' None c. N/A R= ft2 15. Credits CF, Pstat Blass/Floor Area: 0.230 Total Proposed Modified Loads: 48.82 PASS ' Total Baseline Loads: 49.78 Y I hereby -certify that the plans and specifications covered by Review of the plans and S7,q�� this calculation are in compliance with the Florida Energy specifications covered by this �o1413 �, ,� _ p� Code. calculation indicates compliance �`'''%� with the Florida Energy Code. Fr +n,,,�--: = ':•°;��;,, �o PREPARED BY: Before construction is completed DATE: `` ' this building will be inspected for compliance with Section 553.908 ,' a I.,hereby certify that this buildin as designed, is in liance Florida Statutes. with the Florida Energy ode G'OD WE,% OWNER/AGENT BUILDING OFFICIAL: ''GATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 12/15/201711:17 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Fate COPvy Page 1 of 5 FORM R405-2014 PROJECT Title: DAVENPORT RESIDENCE Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 956 Lot # Owner: Total Stories:, 1 Block/SubDivision_ : # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: LOT #35 OCEAN RES Permit Office: Cross Ventilation.: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: ST. LUCIE COUNTY, Family Type: Single-family FL , New/Existing: New (From Plans) Comment: CLIMATE j IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 07.5 % 2.5 %; Winter Summer Degree Days Moisture Range FL, Fort'Pierce FL_VERO_BEACH, MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 956 11324 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 161 1449 No 0 1 1 Yes Yes Yes 2 KITCHEN 238 3332 Yes 0 1 Yes Yes Yes 3 LIVING 306 4284 No 2 1 Yes Yes Yes 4 BATH' 80 720 No 0 1 Yes Yes Yes 5 BEDROOM 2 171 1539 No 1 1 1 Yes, Yes Yes FLOORS # Floor Type, Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet !• 1 Raised Floor BEDROOM ____ ____ 161 ft2 1.9 1 0 0 2 Raised Floor KITCHEN 237.5 ft2 19 1 0 0 3 Raised Floor LIVING ____ 306 ft2 19 1 0 0 4 Raised Floor. BATH ____ ___ 80 ft2 19 1 0 0 5 Raised Floor BEDROOM 2 ____ 171 ft2 19 1 0 0 S ROOF , _ / Roof Gable Roof Solar SA Emitt .Emitt Deck Pitch "/ V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1008 ft2 160 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 956 ft2 Y N 12/15/2017 1-1:17 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 19 Blown 161 ft2 0.1 Wood 2 Under Attic (Vented) KITCHEN 19 Blown 238 ft2 0.1 Wood 3 Under Attic -(Vented) LIVING 19 Blown 306 ft2 0.1 Wood 4 Under Attic (Vented) BATH 19 Blown 80 ft2 0.1 Wood 5 Under Attic (Vented) BEDROOM 2 19 Blown 171 ft? 0.1 Wood WALLS Adjacent Alall Type Space Cavity Width Height Area raming Sheathing Fne Solar Below _ 1 E Exterior Concrete Block - Ext InsIBEDROOM 4.1 15 0 9 6 135.0 ft2 0 0 0.6' 0 _ 2 S Exterior Concrete Block - Ext InSt8EDR0OM 4.1 12 0 9 0 108.0 ft2 0 0 0.6' 0 3 E Exterior Concrete Block - Ext InsuKITC.HEN 4.1 13 0 14 0 182.0 ft2 0 0 0.6 0 4 N Exterior Concrete Block - Ext Insul LIVING 4.1 18 0 14• 6 252.0 ft- z 0 0 0.6 0 5 E Exterior Concrete Block - Ext Insul LIVING. 4.1 17 0 14 0 238.0 ft2 0 0 0.6 0 6 W Exterior Concrete Block- Ext Insul LIVING 4.1 17 0 14 0 238.0 ft2 0 0 0.6 0 7 N Exterior Concrete Block - Ext Insul ;BATH 4.1 8 0 9 0 72.0 ftz 0 0 0.6 0 _ 8 W Exterior Concrete Block - Ext Insul -BATH 4.1 10 0 9 0 90.0 ftz 0 0 0.6 0 9 S Exterior Concrete Block - Ext InfiEDROOM 2 4.1 5 0 9 0 45.0 ft2 0 0 0.6 0 _ 10 SW Exterior Concrete Block - Ext InfiEDROOM 2 4.1 12 9 9 0 114.8 ft2 0 .0 0.6 0 11 W Exterior Concrete Block - Ext InfiEDROOM 2 4.1 7 0 9 0 63.0 ft2 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft in 1 N Insulated LIVING None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang. V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening y 1 E 1 Vinyl Low-E Double Yes 0.29 0.21 15.0 ft2 2 ft 0 in 1 ft 4 in None None 2 E 1 Vinyl Low-E Double Yes 0.29 0.21 15.0 ft2 2 ft 0 in 1 ft 4 in None None 3 E 3 Vinyl Low-E Double Yes 0.29 0.21 9.0 ft2 2 ft 0 in 1 ft 4 in None None 4 N 4 Vinyl Low-E Double Yes 0.29 0.21 15.0 ft2 2 ft 0 in 1 ft 4 in None None 5 E 5 Vinyl Low-E Double Yes 0.29 0.21 30.0 ft2 2 ft 0 in 1 ft 4 in None None 6 W 6 Vinyl Low-E Double Yes 0.3 0.25 80.0 ft2 2 ft 0 in 1 ft 4 in None None 7 SW 10 Vinyl Low-E Double Yes 0.29 0.21 31.0 ft2 2 ft 0 in 1 ft 4 in None None 8 W 11 Vinyl Low-E Double Yes 0.29 0.21 15.5 ft2 2 ft 0 in 1 ft 4 in None None 9 E 1 Metal Double (Tinted) Yes 0.29 0.21 4.5 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 10 N 7 Metal Double (Tinted) Yes 0.29 0.21 4.5 W 2 ft 0 in 1 ft 4 in Drapes/blinds None J 12/15/2017 11:17 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000527 1321.1 12.53 136.4 .3846 7 HEATING SYSTEM # System Type Subtype. Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Single SEER:15:528.6 kBtu/hr cfm 6.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None- BATH 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS / -- Supply — # Location R-Value Area, -- Return -- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Exterior 6 '175 ft2 Exterior 45 ft2 Default Leakage Exterior (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Cooling Jan . Feb Mar Heating HJan Feb Mar Venting Jan Feb X .Mar Ceiling Fans: A . r Ma X Jun X Jul X Au X Se Apr May Jun l Jul , l ] Aug Sep Jun [ Jul [ Aug Sep Oct Nov Oct Nov Dec Dec 12/15/201711.17 AM EnergyGaugeV USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 Thermostat Schedule: Schedule Type HERS 2006 Reference 1 2 3 4 5 Hours 6 7 8 9 -10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78. 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 I 12/15/2017 11:17 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project. Name: DAVENPORT RESIDENCE Builder Name: Street: LOT #35 OCEAN RESORT Permit Office: City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier'shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and: any gaps in the air barrier shall be sealed. Access openings; drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in .substantial contact and. continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing, shall be.sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall"be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be airtight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 12/15/2017 11:17 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the, EnergyP.erformance Index, the more efficient the home. LOT #35 OCEAN RESORT, ST. LUCIE COUNTY, FL, 1. New construction or existing 2. Single family or,multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst -case? 6. Conditioned floor area (ft2 7. Windows- Description a. U-Factor: Dbl, U=0.29 SHGC: SHGC=0.21 b. U-Factor; Dbl; U=0.30 SHGC: SHGC=0.25 c. U-Factor: Dbl, U=0.29 SHGC: SHGC=0:21 d. U-Factor: NIA SHGC: Area Weighted Average Overhang Depth: Area Weighted Average ;SHGC: 8. Floor Types a. Raised Floor b. NIA c. N/A New (From Plans) 9. WaII.Types Insulation Area Single-family, a. Concrete Block- Ext Insul, Exterior R=4.1 153.7.80 ft2 b. N/A R= ft2 1 c. N/A R= ft. 2 d. N/A R= ft2 No 10..Ceiling Typess Insulation Area a. Under Attic (Vented) R=19.0 056.00 ft2 956 b. N/A R= ft2 Area c. N/A R= ft2 130.50 ft2 11. Ducts R ft2 a. Sup: Exterior, Ret: Exterior, AH: Exterior 6 175 80.00 ft2, 12-. Cooling systems kBtu/hr Efficiency 9.00 ft2 a. Central Unit 28:6 SEER:15.50 ft2 13. Heating systems kBtu/hr Efficiency a. Electric Strip, Heat 17.0 COPA.00 2.000 ft. 0:225 Insulation Area 14. Hot.water systems R=19.0 955.50 ft2 a. Electric Cap: 40 gallons EF: 0.97 R= ft2 R= ft2 b. Conservation features None -15. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy -saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, •a new EPL Display Card will be completed based .on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *Note: This. is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge. Rating. Contact the EnergyGauge Hotline at (321) 838-1492 or see the EnergyGauge web site at ene.rgygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/15/2017 11:17 AM EnergyGauge@) USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 - - wrightsoft- Project Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM •ect intormation. For: DAVENPORT RESIDENCE LOT #35 OCEAN RESORT, ST. LUCIE COUNTY, FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Job: Date: Jun 26, 2017 By: Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 12586 Btuh Ducts 4055 Btuh Central vent (23 cfm) 701 Btuh Outside air Humidification 0. Btuh Piping 0 Btuh Equipment load 17342 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Cooling Area (ft2) 956 956 Volume (ft3) 11387 11387 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 85 -- 44 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 4.9 kW 16596 Btuh '16 OF 953 cfm 0.057 cfm/Btuh 0.50 in H2O 90 OF 75 OF 15 OF L 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 15122 Btuh Ducts 6055 Btuh Central vent (23 cfm) 375 Btuh Outside air.:.. Blower 0 -Btuh Use manufacturer's data n Rate/swing multiplier Equipment load 0.95 20474 Btuh sensible Latent Cooling Equipment Load Sizing Structure 2423 Btuh Ducts 1619 Btuh Central vent (23 cfm) 951 Btuh Outside air Equipment latent load 4994 Btuh Equipment total load 25468 Btuh Req. total capacity at 0.70 SHR 2.4 ton Cooling Equipment Summary Make Goodman Mfgg. Trade GOODMAN; JANITROL; AMANA DISTI... Cond GPG1630***M41A Coil AHRI ref 8082383 Efficiency 12.0 EER, 15.5 SEER Sensible cooling 20020 Btuh Latent cooling 8580 Btuh Total cooling 28600 Btuh Actual air flow 953 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H20. Load sensible heat ratio 0.81 Calculations approved_ by ACCA to meet all requirements of Manual J 8th Ed. Wry Ihltsoft` • 017-Dec-1511:22:30 C g Right -Suite® Universal 2017 17.0.14 RSU08.101 File ��� Page 1 4CC�k ...\Quick Calcs\Documents\DAVEN PORT RESIDENCE.rup Calc = MJ8 Front Door faces: N ?x d- wrightsoW Right -A) Worksheet Job: Entire House Date: Jun 26, 2017 QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 Exposed wall 134.7 ft 25.0 ft 3 Room height 11.9 ft d 9.0 ft heat/cool 4 Room dimensions. 1.0 x 147.0 ft 5 Room area 955.5 ftz 147.0 ft' T Y Construction U-value Or HTM I Area ft� I Load I Area ft' I Load I number (Btuh/ft'-°F (Btuh/ft°) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S j Heat Cool 6 VL13A-4ocs 0.143 n 4.00 2.55 324 288 1153 733 0 0 0 0 2 glazing, clr low-e 0.290 n 8.12 8.75 15 0 122 131 0 0 0 0 11 DO 0.390 n 10.92 11.31 21 21 229 238 0 0 0 0 13A-4ocs 0.143 a 4.00 2.55 551 497 1990 1265 117 102 408 260 1 1 2 glazing, clr low-e 0.290 a 8.12 24.53 9 0 73 221 0 0 0 0 2 glazinq. clr low-e 0,290 a 8,12 24.53 _ 45 0 365 1104 15 0 122 368 13A40cs 0.143 s 4.00 2.55 153 133 533 339 108 88 353 225 2 glazing, clr low-e 0.290 s 8.12 8.75 5 5 39 42 5 5 39 42 2 glazing, clr low-e 0.290 s 8.12 8.75 15 15 122 131 15 15 122 131 13A-4ocs 0.143 sw 4.00 2.55 115 81 323 205 0 0 0 0 2 glazing, clr low-e 0.290 sw 8.12 18.88 5 0 38 88 0 0 0 0 2 glazinq, clr low-e 0.290 sw 8.12 18.88 _ 29 0 237 551 0 0 - 0 0 13A-40cs 0.143 w 4.00 2.55 405 304 1216 773 0 0 0 0 2 glazing, clr low-e 0.290 w 8.12 24.53 5 0 38 114 0 0 0 0 2 glazing, clr low-e 0.290 w 8.12 24.53 15 0 122 368 0 0. 0 0 2 glazing, clr low-e 0.310 w 8.68 22.91 82 0 708 1869 0 0 0 0 C 16B-19md 0.049 1.37 2.57 956 956 1311 2458 147 147 202 378 F 20P-19t 0.050 . - 1.40 0.63 956 956 1338 597 147 147 206 92 6 c) AED excursion 1 1 484 -45 Envelope loss/gain 1 9958 11712 1 1 1452 1451 12 a) Infiltration 2628 720 382 105 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 0 0 Appliances/other 2000 0 Subtotal (lines 6 to 13) 12586 15122 1834 1555 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redl^.tribution 0 0 0 .0 14 Subtotal 12586 15122 1834 1555 15. Duct loads 32% 40% 4055 6055 32% 40% 591 623 roomload 16I 21 239 219Airreqdn) I I I 953 953 I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wriiightsat^ 2017-Dec-1511:22:30 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 Quick Calcs\Documents\DAVEN PORT RESIDENCE.rup Calc = MJ8 Front Door faces: N 1- wrightsoft` Right-M Worksheet Job. Entire House Date: Jun 26, 2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name KITCHEN LIVING 2 Exposed wall 13.0 ft 54.0 ft 3 Room height . 14.0 ft heat/cool 14.0 ft heattcool 4 Room dimensions 1.0 x 237.5 ft 1.0 x 320.0 ft 5 Room area 237.5 ft' 320.0 ftz T Y Construction U-value Or HTM I Area ft' I Load I Area ft' I Load I number (Btuhll!V- F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool j Gross I NIP/S j Heat Cool Gross NIP/S Heat Cool 6 VL13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 252 216 865 550 2 glazing, clr low-e 0.290 n 8.12 8.75 0 0 0 0 15 0 122 131 11D0 0.390 n 10.92 11.31 0 0 0 0 21 21 229 238 13A-40cs 0.143 a 4.00 2.55 182 173 693 440 252 222 889 565 11 2 glazing, clr low-e 0.290 a 8.12 24.53 9 0 73 221 0 0 0 0 LLL���� 2 alazinc, clr low-e 0,290 a 8,12 24,53 0 0 0 0 30 0 244 736 V�+ 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.290 s 8.12 8.75' 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.290 s 8.12 8.75 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.290 sw 8.12 18.88 0 0 0 0 0 0 0 0 2 glazing. clr low-e 0.290 sw 8.12 18.88 _ 0 0 0 0 0 _ 0 0 0 13A4ocs 0.143 w 4.00 2.55 0 0 0 0 252 170 682 434 2 glazing, clr low-e 0.290 w 8.12 24.53 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.290 w 8.12 24.53 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.310 w 8.68 22.91 0 0 0 0 82 0 708 1869 C 16B-19md 0.049 1.37 2.57 238 238 326 611 320 320 439 823 F 20P-19t 0.050 1.40 0.63 238 238 332 148 320 320 448 200 61 c) AED excursion 1 -681 1 1 1 221 Envelope loss/gain 1424 1353 1 1 4626 5766 12 a) Infiltration 309 85 1284 352 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 2000 0 Subtotal (lines 6 to 13) 1733 3437 5910 6578 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1733 3437 5910 6578 15 Duct loads 32% 40% 558 1376 32% 40% 1904 2634 2131I 4217I- 7448I 9415I Airrequomdl(adnj I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ' f1 Wrighttsaft- 2017-Dec-15 11:22:30 Rig ht-Suite® Universal 2017 17.0.14 RSU08101 Page 2 ...1Quick CalcslDocumentslDAVEN PORT RESIDENCE.rup Calc = MJ8 Front Door faces: N + wrightsoW Right-JO Worksheet Entire House QUICK CALCS, INC. . 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Jun 26, 2017 By: 1 Room name BATH BEDROOM 2 2 Exposed wall 18.0 ft 24.7 ft 3 Room height 9.0 ft heat/cool _ 9.0 ft heat/cool 4 Room dimensions 10.0 x.. 8.0 ft • 1.0 x . 171.0 . ft 5 Room area 80.0 ft2 171.0 ft2 T y Construction U-value Or HTM I Area(ft2)Load I I Area ft' I Load I number (Btuh/ft2-°F (Btuh/W) or perietr (ft) (Btuh) or perimeter (ft) (Btuh) . Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 0.143 n 4.00 2.55 72 72 288 183 0 0 0 0 VL13A-4ocs 2 glazing, clr low-e 0.290 n 8.12 8.75 0 0 0 0 0 0 0 0 11DO 0.390 n 10.92 11.31 0 0 0 0 0 0 0 0 �1 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1 1 2 glazing, clr low-e 0.290 a 8.12 24.53 0 0 0 0 0 0 0 0 2 glazinq, clr low-e 0,290 a 8.12 24.53 0 0 0 0 0 0 0 0 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 45 45 180 115 2 glazing, clr low-e 0.290 s 8.12 8.75 0 0 0 0 0 0 0 0 2 glazing, clr low-e _ 0.290 s 8.12 8.75 0 0 0 0 0 0 0. , 0 13A-40cs 0.143 sw 4.00 2.55 0 0 0 0 115 81 323 205 2 glazing, clr low-e 0.290 sw 8.12 18.88 0 0 0 0 5 0 38 88 2 alazinq. clr low-e 0.290 sw 8.12 18.88 0 0 0 0 29 0 237 551 13A-4ocs 0.143 w 4.00 2.55 90 85 342 217 63 48 192 122 2 glazing, clr low-e 0.290 w 8.12 24.53 5 0 38 114 0 0 0 0 2 glazing, clr low-e 0.290 w 8.12 24.53 0 0 0 0 15 0 122 368 2 glazing, clr low-e 0.310 w 8.68 22.91 0 0 0 0 0 0 0 0 C 16B-19md 0.049 1.37 2.57 80 80 110 206 171 171 235 440 F 20P-19t 0.050 1.40 0.63 80 80 112 _ 50 171 171 239 107 6 c) AED excursion 1 1 301 1 1 1 346 Envelope loss/gain I 890 1 800 1 1 1566 2342 12 a) Infiltration 275 75 378 103 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 1165 876 1944 2675 Less external load 0 0 0 0 Less transfer 0 0 0 0 Re(iistribution 0 0 0 0 14 Subtotal 1165 876 1944 2675 15 Duct loads . 32% 40% 375 351 32% 40% 626 1071 Air 1588I 1255I 2147 31 I I requi dload (cfm) . I I I I I I 69 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ~ '�- WrightSOfft- 2017-Deo-1511:22:30 E_Rig ht-Suite® Universal 2017 17.0.14 RSU08101 Page 3 M...\Quick CaIcsXDocuments\DAVEN PORT RESIDENCE.rup Calc = MJ8 Front Door faces: N Duct System Summary Job: 1N�'Ii1tSOfta Date: Jun 26, 2017 Entire House By: QUICK CALCS, INC. 317 ST-LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Project• • For: DAVENPORT RESIDENCE LOT #35 OCEAN RESORT, ST. LUCIE COUNTY, FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O . Lowest friction rate 0.283 in/100ft 0.283 in/100ft Actual air flow 953 cfm 953 cfm Total effective length (TEL) 177 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 1.540 88 55 0.286 4.0 .00 VIFx 40.0 135.0 st2.. BEDROOM 2 c 3747 147 169 0.283 .8.0 Ox 0 VIFx 41.8 135.0 st2 KITCHEN c 4814 . 131 21'7 0:293 8.0 Ox 0 . , VIFz 35:5 135.0 st2 LIVING -A h 3907 . 224 207 0.376. 8.6. Ox 0 VIFx 17.9 115.0 LIVING-B h .3907 224 207 0.368 . 8.0 Ox 0 VIFx '. 20.8 115.0 st1 MASTER BEDROOM h 2425 139 98 0.286 7.0 Ox 0 VIFx 39.6 135.0 . st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) - (in) Material Trunk. st2 Peak AVF 506 539 �-0.283 686 12.0 0 x 0 VinlFlx st1 st1 Peak AVF. 953 953 0.283 892 14.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 953 953 0 0 0 0 Ox 0 VIFx ss 2017-Dec-15 11:22:30 . 'wrightso ' Right -Suite® Universal•2017 17.0.14 RSU08101 - Page 1 M...\Quick CaicsNDocuments\DAVEN PORT RESIDENCE.rup Calc = MJ8 Front Door faces: N