HomeMy WebLinkAboutREVIEW COMMENTS 8-9-17r ^�
Y
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462-6443
AUG o 9 2017REVIEW COMMENTS
Public Works
St. Lucie County, 1=L
PROPERTY INFORMATION
Address: 5295 Compass Cove PI
City / State / Zip: Fort Pierce, FI 34949
Parcel #: 1410-502-0035-000/7
Zoning: HIRD
Page 1
Owner(s):
John Davenport / Laurie Cortes
Jurisdiction: SAINT LUCIE COUNTY
Lot#:
APPLICATION INFORMATION
Permit Number: 1706-0234 Stories-
Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS)
Block:
Automatic Sprinkler System? No
CONTRACTOR INFORMATION
Contractor Name: �S e l � �d1n A) V e n Fax Number:
Business Name- r
Business Addr:- Email: 1 Qu.ri -
�y��
City/State/Zip:
REVIEWS AND COMMENTS
Review JI pe
DOCUMENTS MISSING
Status Revlewed By Date Started Date Completed Date Released
PENDING Angela Huff W14/2017
(n� 6/14/2017,6omment:
VEGETATION REMOVAL IN DRAWER UNDER (D) NO FEE.
6/21/2017 ���- Comment:
RECORDED NOTICE OF COMMENCEMENT.
ENVIRONMENTAL REVIEW
COMPLETE Lynn Swartzel 6/12/2017 6/13/2017 6n3/2017
Comment:
FRONT COUNTER REVIEW
COMPLETE Audrey Humphrey 6IM017 SWO17 6/9/Y017
Comment:
IEW
PLANS EXAMINER7vCoo-Wment-:,f-':"t'PLEASE
INCOMPLETE Gfa-Englneer 6/2MO17
PROVIDE 2 COPIES (BOTH WITH AN ORIGINAL SIGWSEAL, EMBOSSED OR WET SEAL AS NO
6/29/2017 /
`J 111���"���^^^"��`
DIGITAL OR E STAMPS WILL BE ACCEPTED) OF THE ST LUCIE COUNTY CERTIFICATION FOR DESIGN LOAD
COMPLIANCE FORM. COPY AND PASTE LINK TO DOWNLOAD
HTTPJ/W W W_STLUCIECO.GOV/HOME/SI JOWD000MENT?ID=1288
C,pinment:
PLEASE SUBMIT IN DUPLICATE THE ST LUCIE COUNTY PRODUCT REVIEW AFFIDAVIT COMPLETE WITH
FLORIDA PRODUCT APPROVAL OR N.O.A. NUMBER WITH COVER SHEET, INSTALLATION INSTRUCTIONS,
6/29/2017
SIGNED/SEALED AND DATED BY THE DESIGNER OF RECORD FOR ALL COMPONETS AND CLADING IN
!
ACCORDANCE WITH 553.842 OF THE FLORIDA STATUTES. COPY AND PASTE LINK FOR ST. LUCIE COUNTY
PRODUCT REVIEW AFFIDAVIT HTTP•JANWW.STLUCIECO.GOVIHOME/SHOWDOCUMENT?ID=1262
Comment:
PLEASE PROVIDE ENERGY CALCS FORM R405 IN DUPLICATE THAT INCLUDE AN ORIGINAL SIGNATURE BY
6/29/2017
THE PREPARER IN ACCORDANCE WITH SECTIONS 402 AND 403 OF THE 2014 FLORIDA ENEGRY CODE
FIFTH EDITION.
Comment:
:j PLEASE PROVIDE A MANUAL J IN ADDITION TO A DUCT PLAN SHOWING A BALANCED SYSTEM, DUCT
6/29/2017
SIZE, GRILL SIZE, AND ROOM BY ROOM COOLING CFMS PER 107.2.1 OF THE 2014 FLORIDA BUILDING
CODE.
�1-
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462-6.443
PROPERTY INFORMATION
Address: 5295 Compass Cove PI
City / State / Zip: Fort Pierce, FI 34949
Parcel #: 1410-502-0035-000/7
Zoning: HIRD
APPLICATION INFORMATION
REVIEW COMMENTS
Page 1
Owner(s):
John Davenport / Laurie Cortes
Jurisdiction: SAINT LUCIE COUNTY
Lot#:
Permit Number: 1706-0234 Stories:
Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS)
CONTRACTOR INFORMATION
Contractor Name:
Business Name:
Business Addr:
City / State / Zip:
REVIEWS AND COMMENTS
Block:
Automatic Sprinkler System? No
Fax Number:
Email:
Review Type
Status Reviewed By Date Started Date Completed Date Released
DOCUMENTS MISSING
PENDING Angela Huff 6/14/2017
6/14/2017 Comment:
VEGETATION REMOVAL IN DRAWER UNDER (D) NO FEE.
ENVIRONMENTAL REVIEW
COMPLETE Lynn Swartzel 6/12/2017 6/13/2017 6/1312017
Comment:
FRONT COUNTER REVIEW
COMPLETE Audrey Humphrey 6/9/2017 6/9/2017 61912017
Comment:
PE REVIEW COMMENTS (2)
INCOMPLETE Gfa-Engineer 8/14/2017
Comment:
PLEASE PROVIDE 2 COPIES (BOTH WITH AN ORIGINAL SIGN/SEAL, EMBOSSED OR WET SEAL AS NO
DIGITAL OR E STAMPS WILL.BE ACCEPTED) OF THE ST LUCIE COUNTY CERTIFICATION FOR DESIGN LOAD
COMPLIANCE FORM. COPY AND PASTE LINK TO DOWNLOAD
6/29/2017
HTTP://WWW.STLUCIECO.GOV/HOME/SHOWDOCUMENT?ID=1288
THE CERTIFICATION FOR DESIGN LOAD COMPLIANCE WAS PROVIDED BUT ITEM #6 ZONE 1, 2 AND 3 ARE
NOT LISTED. PLEASE COMPLETE. NOTE THIS INFORMATION WILL CORRESPOND WITH THE ST LUCIE
COUNTY PRODUCT REVIEW AFFIDAVIT AND THE INFORMATION LISTED ON THE PRODUCT APPROVALS
Comment:
PLEASE SUBMIT IN DUPLICATE THE ST LUCIE COUNTY PRODUCT REVIEW AFFIDAVIT COMPLETE WITH
FLORIDA PRODUCT APPROVAL OR N.O.A. NUMBER WITH COVER SHEET, INSTALLATION INSTRUCTIONS,
SIGNED/SEALED AND DATED BY THE DESIGNER OF RECORD FOR ALL COMPONETS AND CLADING IN
6/29/2017
ACCORDANCE WITH 553.842 OF THE FLORIDA STATUTES. COPY AND PASTE LINK FOR ST. LUCIE COUNTY
PRODUCT REVIEW AFFIDAVIT HTTP:/MWW.STLUCIECO.GOV/HOME/SHOWDOCUMENT?ID=1262
THIS HAS NOT BEEN ADDRESSED AND MUST BE COMPLETED BY THE ENGINEER OF RECORD
Planning& Development Services REVIEW COMMENTS
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:(772)462-2172 Fax:(772)462-6443
`Comment:
PLEASE SPECIFY THE BOTTOM CHORD TRUSS BRACING REQUIREMENTS FOR (RAT RUNS) PER FBC
6/29/2017
.�
R802.1.7.3
ment:
PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND
6/29/2017
APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61 G15-30.005 OF THE FLORIDA
ADMINISTRATIVE CODE
Comment:
PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2014 FLORIDA BUILDING
6/29/2017
V
CODE WITH ORIGINAL SIGN/SEAL (EMBOSSED OR WET SEAL) AS NO DIGITAL OR E STAMP/SIGNATURE
WILL BE ACCEPTED
/Comment:
PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE WITH THE NAME, ADDRESS AND LICENSE
6/29/2017
NUMBER OF THE ENGINEER OF RECORD ON THE COVER PAGE PER 61 G15-31.003 OF THE FLORIDA
ADMINISTRATIVE CODE
mc%— nt°
PLEASE FURNISH A INTERIOR WALL DETAIL SHOWING STUD SPACING, STUD SIZE, AND WALL FINISH IN
6/29/2017
ACCORDANCE WITH 602.2 OF THE 2014 FLORIDA BUILDING CODE
6/29/2017
nriment:
PLEASE SHOW THE BEDROOM WINDOWS AS EGRESS PER 107.2.3 OF THE 2014 FLORIDA BUILDING CODE
Commeht:.
PLEASE SHOW HYDRO VENTS WITH IN 12" OF GRADE IN ACCORDANCE WITH 322.2.2 OF THE 2014
6/29/2017
IN N. ,
FLORIDA RESIDENTIAL CODE
Cohiment:
PLEASE SHOW ON THE PLANS THE CLEAR NET AREA OF EACH VENT BEING USED AS HYDRO VENTS
6/29/2017
WITH THE MANUFACTURES SPECIFICATION IN ACCORDANCE WITH 322.2.2 OF THE 2014 FLORIDA
RESIDENTIAL CODE
6/29/2017
Comment:
THE LOFT AREA DOES NOT COMPLY WITH THE MINIMUM CEILING REQUIREMENTS SET FORTH BY
SECTIONS R304 AND R305 OF THE FBC 2014. PLEASE REVISE
6/29/2017
mment-,
PLEASE PROVIDE A PERMANENT STAIRWAY DETAIL FOR THE PROPOSED LOFT IN WITH
"311.7 OF THE FBC 2014
6/29/2017
Xk)
PLEASE PROVIDE A INTERIOR BEARING WALL DETAIL IN COMPLIANCE WITH CHAPTER 6 OF THE FBC 2014
RESIDENTIAL
6/29/2017
Comment: j PLEASE FURNISH LOAD CALULATIONS FOR ELETRICAL
6/29/2017
Commehf1:
PLEASE SHOW CARBON MONOXIDE ALARM WITHIN 10 FOOT OF EACH ROOM USED FOR SLEEPING IN
3
ACCORDANCE WITH 315.1 OF THE 2014 FLORIDA RESIDENTIAL CODE
6/29/2017
omment:
PLEASE SHOW FLAME SPREAD INDEX AND SMOKE DEVELOPED INDEX FOR WALL AND CEILING FINISHES
IN ACCORDANCE WITH SECTION 302.9 OF THE 2014 FLORIDA RESIDENTIAL CODE
6/29/2017T
ment: `'
PLEASE SHOW THE FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR THE INSULATION AS REQUIRED
IN SECTION 302.10 OF THE 2014 FLORIDA RESIDENTIAL CODE
6/29/2017
t-m' ment:
PLEASE FURNISH PLUMBING RISER DIAGRAM BEING IN ACCORDANCE WITH 3004 AND 3005 OF THE 2014
FLORIDA RESIDENTIAL CODE.
6/29/2017
.hJJ
✓ment;
PLEASE COMPLETE THE GAS PIPING SCHEMATIC WORK SHEET
6/29/2017
Comont:
PLEASE PROVIDE ALL CONNECTION DETAILS FOR THE PROPOSED DECKS PER FBC 107.2
6/29/2017
m"Mont
THE TRUSS LAYOUT PAGE FOR THE PROPOSED STRUCTURE DOES NOT MATCH THE ELEVATION PAGES
AS ON IS FOR A HIP ROOF AND THE OTHER IS FOR A GABLE ROOF. FBC 107.2
Comment: 1
PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE
6/29/2017
/
SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED
V
DOCUMENTS
Comment/ PLEASE NOTE: (1) ALL REVIEW COMMENTS WHEN ANSWERED WILL REQUIRE A COVER LETTER
�V/ ADDRESSING WHERE THE CHANGES WERE MADE, (2) ALL CHANGES WILL BE REQUIRED TO BE CLOUDED
6/29/2017
ON THE PLANS AND (3) THE CONTRACTOR WHEN RESUBMITTING WILL BE REQUIRED TO INSERT THE
NEW UPDATED PAGES INTO THE PLANS OR IF THE CONTRACTOR PREFERS, A REVISED COMPLETE SET
OF PLANS CAN BE SUBMITTED
6/29/2017
✓Comment: PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER
ST. LUCIE COUNTY RESOLUTION #13-196
6/29/2017
Comment: COMMENTS SENT 6/29/17
ZONING REVIEW
INCOMPLETE Lydia Galbraith 6/21/2017
Comment: SURVEYS ARE REQUIRED FOR ALL BUILDING PERMITS INVOLVING A PRIMARY STRUCTURE AND FOR ALL
6/21/2017 ACCESSORY STRUCTURES WITH A CONSTRUCTION VALUE EXCEEDING $10,000.00. THE SURVEYS ARE
REQUIRED TO BE SIGNED & SEALED BY A REGISTERED FLORIDA SURVEYOR.
r-.
Planning & Development Services
Building &Code Regulation Division
2306 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462-6443
REVIEW COMMENTS
Page 2
Comment:
PLEASE PROVIDE ENERGY CALCS FORM R405 IN DUPLICATE THAT INCLUDE AN ORIGINAL SIGNATURE BY
THE PREPARER IN ACCORDANCE WITH SECTIONS 402 AND 403 OF THE 2014 FLORIDA ENEGRY CODE
6/29/2017
FIFTH EDITION.
THIS COMMENT HAS BEEN ADDRESSED BUT MANY ITEMS LISTED ON THE WINDOW PORTION PAGE 3 OF 5
ARE INCORRECT INCLUDING NUMBER OF WINDOWS, U-FACTOR AND OVERHANG
Comment:
PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND
APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA
ADMINISTRATIVE CODE
6/29/2017
THIS COMMENT WAS ADDRESSED BUT APPROVED BY THE WRONG INDIVIDUAL. PLEASE HAVE THE
ENGINEER OF RECORD REVIEW AND APPROVE THE TRUSS PLACEMENT DRAWING. ALSO THE PROPOSED
FLOOR TRUSSES MUST BE INCLUDED IN THE DRAWING OR HAVE ITS OWN PLACEMENT DRAWING
Comment:
THE LOFT AREA DOES NOT COMPLY WITH THE MINIMUM CEILING REQUIREMENTS SET FORTH BY
SECTIONS R304 AND R305 OF THE FBC 2014. PLEASE REVISE
6/29/2017
THIS COMMENT WAS NOT ADDRESSED AS PLAN PAGE 2 STILL SHOWS A RAILING WITH PULL DOWN
STAIRS. EITHER THE STORAGE AREA NEEDS TO BE INCLUDED IN THE MANUAL J AND DUCT PLAN OR THE
ROOF -MUST BE WALLED OFF WITH THOSE WALLS INCLUDED IN THE THERMAL ENVELOPE FOR WHICH A
DETAIL OF THE STORAGE WALLS WILL BE REQUIRED AND INCLUDED IN THE ENERGY CALCS
Comment:
THE PROPOSED METAL ROOF PANELS DO NOT MEET THE DESIGN PRESSURE CRITERIA FOR ZONES 1, 2
AND 3 FOR EXPOSURE CATEGORY D AND NEED TO BE LISTED FOR EACH PER FBC 107.2. PLEASE PRINT
6/29/2017
THE PRODUCT APPROVAL AND INSTALLATION INSTRUCTIONS IN DUPLICATE ONCE THE CORRECT
PRODUCT IS FOUND
Comment:
PLEASE PRINT OUT ALL PRODUCT APPROVALS IN DUPLICATE WITH INSTALLATION INSTRUCTIONS PER
6/29/2017
FBC 107.2
Comment:
THE PROPOSED 2X6 FLOOR JOISTS FOR THE STORAGE AREA AT 24" O.C. EXCEED THE MAXIMUM SPAN
8/14/2017
AS SHOWN BY TABLE 2308.8 OF THE FBC 2014. PLEASE DETAIL SPECIFICALLY THE O.C. SPACING AND THE
APPROPRIATE SIZE FLOOR JOISTS
Comment:
PLEASE DETAIL THE 2X8 CONVENTIONAL ROOF FRAMING ON CENTER SPACING IN COMPLIANCE WITH
8/14/2017
TABLE 2308.8 OF THE FBC 2014
Comment:
PLEASE INCLUDE THE ENGINEERING SIGNED AND SEALED FOR THE TJI PRO FLOOR JOISTS PER FBC
8/14/2017
107.2
Comment:
PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE SUBMITTED
DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS
PLEASE NOTE: (1) ALL REVIEW COMMENTS WHEN ANSWERED WILL REQUIRE A COVER LETTER
ADDRESSING WHERE THE CHANGES WERE MADE, (2) ALL CHANGES WILL BE REQUIRED TO BE CLOUDED
ON THE PLANS AND (3) THE CONTRACTOR WHEN RESUBMITTING WILL BE REQUIRED TO INSERT THE
8/14/2017
NEW UPDATED PAGES INTO THE PLANS OR IF THE CONTRACTOR PREFERS, A REVISED COMPLETE SET
OF PLANS CAN BE SUBMITTED
PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST.
LUCIE COUNTY RESOLUTION #13-196
8/14/2017 Comment: COMMENTS SENT 6/29/17 AND 8/14/17 FOR 2ND REVIEW
PLANS EXAMINER REVIEW COMPLETE Gfa-Engineer 6129/2017 8/14/2017 8/14/2017
Comment:
ZONING REVIEW INCOMPLETE Lydia Galbraith 6/21/2017
Comment: SURVEYS ARE REQUIRED FOR ALL BUILDING .PERMITS INVOLVING A PRIMARY STRUCTURE AND FOR ALL
6/21/2017 ACCESSORY STRUCTURES WITH A CONSTRUCTION VALUE EXCEEDING $ 10,000.00. THE SURVEYS ARE
REQUIRED TO BE SIGNED & SEALED BY A REGISTERED FLORIDA SURVEYOR. .
Planning & Development Services.
Building & Code Regulation Division.
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462-6443
REVIEW COMMENTS
e3
Comment:
PLEASE INDICATE ON THE SURVEY THE FOLLOWING INFORMATION:
- PROPOSED STRUCTURE, DECKS AND STEPS/LANDING
- SETBACK TO LOT LINE AND SETBACK TO NEIGHBOR STRUCTURES. THE SETBACKS ARE FRONT 10', LEFT
SIDE 8', RIGHT SIDE 0' AND REAR 5'. SINCE THE PROPERTY HAS LOT LINES AND NOT RECORDED
PROPERTY LINES THE SIDE SETBACK BETWEEN STRUCTURES WILL NEED TO BE AT LEAST 8' STRUCTURE
6/21/2017
TO STRUCTURE
- INDICATE THE DISTANCE FROM PROPOSED STRUCTURE TO NEXT DOOR STRUCTURES (BOTH SIDES).
- PROPOSED FINISHED FLOOR ELEVATION, MIN. IS 18" ABOVE CENTERLINE OF THE ADJACENT ROAD.
- ELEVATION OF CENTERLINE ROAD.
-,ELEVATION OF GRADE AT LOCATION OF PROPOSED STRUCTURE.
- (2) PARKING SPACES OF 8'X18' EACH.
6/21/2017 Comment:
THE APPROVAL STAMP OF OCEAN RESORTS SEEMS TO BE FROM 1992 AND IS NOT MATCHING THE
PROPOSED PLANS. PLEASE PROVIDE A STAMP ON THE UPDATED SURVEY.
6/21/2017 Comment:
PLEASE PROVIDE (2) UPDATED SURVEYS SIGNED AND SEALED BY SURVEYOR
6/21/2017 Comment:
PLEASE INDICATE ALL NAMES OF ROOMS ON THE BUILDING PLANS.
6/21/2017 Comment:
THE REAR STEPS MAY ENCROACH INTO THE 5' REAR SETBACKS. HOWEVER, IF BOTH STEPS AND
LANDING ARE ENCROACHING THE DECK MAY NOT BE LARGER THAN 4'X4'.
6/21/2017 Comment:
STEPS ON THE SIDE ARE NOT ALLOWED THE ENCROACH INTO THE 8' SIDE SETBACK.
6/21/2017 Comment:
FLOOR PLAN REQUIRED TO INDICATE THE TOTAL SF.
Comment:
PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS
6/21/2017
EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.
r
�Glfilfi UL't y
Planning & Develooment.Servicea
Bullding 8 Code:Regulation Division .
2300 VirginiaAvenue
Fort Pierce, FL. 34982 ,
Phone:(772)462-2172 . ax:(772j4fi2-6443
REVIEW COMMENTS
Comment: PLEASE INDICATE ON THE SURVEY THE FOLLOWING INFORMATION:
- PROPOSED STRUCTURE, DECKS AND STEPS/LANDING
- SETBACK TO LOT LINE AND SETBACK TO NEIGHBOR STRUCTURES. THE SETBACKS ARE FRONT 10',
LEFT SIDE 8', RIGHT SIDE 0' AND REAR 51. SINCE THE PROPERTY HAS LOT LINES AND NOT RECORDED
PROPERTY LINES THE SIDE SETBACK BETWEEN STRUCTURES WILL NEED TO BE AT LEAST 8'
6/21/2017 STRUCTURE TO STRUCTURE
INDICATE THE DISTANCE FROM PROPOSED STRUCTURE TO NEXT DOOR STRUCTURES (BOTH SIDES).
- PROPOSED FINISHED FLOOR ELEVATION, MIN. IS 18" ABOVE CENTERLINE OF THE ADJACENT ROAD.
- ELEVATION OF CENTERLINE ROAD.
- ELEVATION OF GRADE AT LOCATION OF PROPOSED STRUCTURE.
- (2) PARKING SPACES OF 8%18' EACH.
6/21/2017 rComme THE APPROVAL STAMP OF OCEAN RESORTS SEEMS TO BE FROM 1992 AND IS NOT MATCHING THE
PROPOSED PLANS. PLEASE PROVIDE A STAMP ON THE UPDATED SURVEY. --
6/21/2017
Comment:
PLEASE PROVIDE (2) UPDATED SURVEYS SIGNED AND SEALED BY SURVEYOR
6121/2017
o ment:
�;o1 F.
PLEASE INDICATE ALL NAMES OF ROOMS ON THE BUILDING PLANS.
6/21/2017
Comment:
THE REAR STEPS MAY ENCROACH INTO THE 5' REAR SETBACKS. HOWEVER, IF BOTH STEPS AND
.
LANDING ARE ENCROACHING THE DECK MAY NOT BE LARGER THAN 41A4'.
6/21/2017
Comment:
STEPS ON THE SIDE ARE NOT ALLOWED THE ENCROACH INTO THE 8' SIDE SETBACK.
6/21/2017
C6m�:
FLOOR PLAN REQUIRED TO INDICATE THE TOTAL SF.
6/21/2017
Comment;
PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS
`//