Loading...
HomeMy WebLinkAboutREVISIONFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: DAVENPORT RESIDENCE Builder Name: i Street: LOT #35 OCEAN RESORT Permit Office: City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number. Owner. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1537.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1537.80 ft2 I 3. Number of units, if multiple family 1 b. NIA c. N/A R= ft2 R= ft2 4. Number of Bedrooms 2 d. N/A . R= ft2 5. Is this a worst case? No 10. Ceiling Types (956.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 956.00 ft2 6. Conditioned floor area above grade (ft2). 956 b. WA R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(219.5 sqft.) Description Area 11. Ducts R ft2 a. U-Factor. Dbl, U=0.29 130.50 ft2 SHGC: SHGC=0.21 b. U-Factor: Dbl, U=0.30 80.06 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 35.2 SEER:18.00 c. U-Factor. Dbl, U=0.29 9.00 ft2 SHGC: SHGC=0.21 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a. Electric Heat Pump 21.4 HSPF:9.40 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.225 14. Hot water systems 8. Floor Types (955.5 sqft.) Insulation Area a. Electric Cap:'40gal lons a. Raised Floor R=20.0 955.50 ft2 b. Conservation features EF: 0.970 .970 b. WA R= ft2 None c. N/A R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.230 Total Proposed Modified Loads: 39.00 PASS Total Baseline Loads:. 50.02 I hereby certify that the plans and specifications covered by Review of the plans and ST,g1� this calculation are in compliance with the Florida Energy specifications covered by this D�-fNE �+ Code. calculation indicates compliance With the Florida Energy Code. ��.,,, h aurr''� .`.;:=_�',•°.�,� PREP ED Before construction is completed .. DATE: .. this building will be .inspected for compliance with Section 553.908 * �, I herebycertify that this building as desi ned, is in c flr 9. 9 pliance Florida Statutes. G'OD with the Florida Energy de. WE OWNER/ GENT. BUILDING OFFICIAL: DATE: �� - �'ti DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordanc this proiect requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402. ,iiiiiria ii1i,.® . I NUv I b 2018 10/23/2018 8:46 AM EnergyGauge® USA Section R405.4.1 Compliant ermitting Departrnvi St. Lucie Coun+-!y, 'vL "FORM R405-2017 SI IMMORY C'_I-IPCI(I I-QT Q5=0nQ•.- PROJECT Title: DAVENPORT RESIDENCE Bedrooms: 2 Address Type: Street (Address Building Type: User Conditioned Area: 956 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: LOT #35 OCEAN RES Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: ST. LUCIE COUNTY, Family Type: Single-family FL, NeWedsting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture i Range FL, Fort Pierce FL VERC BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 956 11324 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished ICooled Heated 1 BEDROOM 161 1449 No 0 1 1 Yes Yes Yes 2 KITCHEN 238 W32 Yes 0 1 Yes Yes Yes 3 LIVING 306 4284 No 2 1 Yes iYes Yes 4 BATH 80 720 No 0 1 Yes Yes Yes 5 BEDROOM 2 171 1539 No 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor BEDROOM ___- 161 ft2 20 1 0 0 2 Raised Floor KITCHEN — ____ 237.5 ft2 20 1 0 0 3 Raised Floor LIVING _ ,__ 306 ft2 20 1 0 0 4 Raised Floor BATH ____ 80 f12 20 1 0 0 5 Raised Floor BEDROOM 2 ____ ___ 171 ft2 20 1 0 I 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck . Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1008 ft2 160 ft2 Light 0.6 No 0.9 No 20 18.4 ATTIC / v # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 956 ft2 N N 10/23/2018 8:46 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 iWA , r RI IMMeRY [_I-IF['_b[I ICT R=DAI?T CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BEDROOM 20 Blown 161 ft2 0.1 Wood 2 Under Attic (Unvented) KITCHEN 20 Blown 238 11:2 0.1 Wood 3 Under Attic (Unvented) LIVING 20 Blown 306 ft2 0.1 Wood 4 Under Attic (Unvented) BATH 20 Blown 80 ft2 0.1 Wood 5 Under Attic (Unvented) BEDROOM 2 20 Blown 171 ftZ 0.1 Wood WALLS Adjacent Space 10 Wall Tuno Cavity ' Width Height 0-Vable Et In Sheathing Framing Solar Below a _ 1 E Exterior Concrete Block - Ext InsiBEDROOM 4.1 15 0 9 0 135.0 11:2 0 0 0.6 0 _ 2 S Exterior Concrete Block - Ext InsIBEDROOM 4.1 12 0 9 0 108.0 ft2 0 0 0.6 0 _.3 E Exterior Concrete Block --Ext InsuKITCHEN 4.1 13 0 14 0 182.0 ft2 0 0 0.6 0 _ 4 N Exterior Concrete Block - Ext Insul LIVING 4.1 18 0 14 0 252.0 ft2 0 0 0.6 0 _ 5 E Exterior Concrete Block - Ext Insul LIVING 4.1 17 0 14 0 238.0 ft2 0 0 0.6 0 _ 6 W Exterior Concrete Block - Ext Insul LIVING 4.1 17 0 14 0 238.0 ft2 0 0 0.6 0 7 N Exterior Concrete Block - Ext Insul BATH 4.1 8 0 9 0 72.0 ft2 0 0 0.6 0 _ 8 W Exterior_ Concrete Block - Ext Insul BATH 4.1 10 0 9 0 90.0 ft2 0 0 0.6 0 9 S Exterior Concrete Block - Ext InfiffDROOM 2 4.1 5 0 9 0 45.0 ft2 0 0 0.6 0 10 SW Exterior Concrete Block - Ext InREDROOM 2 4.1 12 9 9 0 114.8 ft2 0 0 0.6 0. -11 W Exterior Concrete Block - Ext InfiffDROOM 2 4.1 7 0 9 0 63.0 ft2 0 0 0.6 0 DOORS V. # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated LIVING None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. ` / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.29 0.21 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 2 E - 1 Vinyl Low-E Double Yes 0.29 0.21 N . 15.0 ft2 2 It 0 in 1 ft 4 in None None 3 •E 3 Vinyl Low-E Double Yes 0.29 0.21 N 9.0 ft2 2 ft 0 in 1 ft 4 in None None 4 N 4 Vinyl Low-E Double Yes 0.29 0.21 N 15.0 ft2 2 It 0 in 1 ft 4 in None None 5 E 5 Vinyl . Low-E Double Yes 0.29 0.21 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 6 W 6 Vinyl Low-E Double Yes 0.3 0.25 N 80.0 ft2 2 ft 0 in 1 ft4 in None None 7 SW 10 Vinyl Low-E Double Yes 0.29 0.21 N 31.0 ft2 2 ft 0 in 1 ft 4 in None None 8 W 11 Vinyl . Low-E Double Yes 0.29 0.21 N 15.5 ft2 2 It 0 in 1 ft 4 in None None 9 E 1 Metal Double (Tinted) Yes 0.29 0.21 N 4.5 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 10 N 7 Metal Double (Tinted) Yes 0.29 0.21 N 4.5 ft2 2 It 0 in 1 ft 4 in Drapes/blinds None 10/23/2018 8:46 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY rI4F:r C1 ICT RIFpnQT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000527 1321.1 72.53 136.4 . .4294 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:9.4 21.4 kBtu/hr 1 Ductless COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Single SEER: 18 35.2 kBtu/hr 1056 cfm 0.8 1 Ductless HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None BATH 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [ ]Jan [ ] Feb [[ jj Mar Heating [X] Jan [X] Feb [X] Mar ( A r [ Apr [ Ma jxj Jun ri Jul rl Au rl Se [ May Jun Jul AuSep W Oct Nov Oct H Nov [ ]Dec [X] Dec Venting [ ]Jan [ j Feb [[XX]] Mar [X A r [ Ma Jun JulAug Se Oct Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 7B 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating'(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66. MASS Mass Type Area Thickness Fumiture Fraction Space . Default(8 Ibs/sq.ft. 0 ftz 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ftz ft 0.3 KITCHEN Default(8 lbs/sq.ft. ftz ft 0.3 LIVING Default(8 lbs/sq.ft. ftz ft 0.3 BATH Default(8 Ibs/s .ft. ftz ft 0.3 BEDROOM 2 Name: Test Rater Signature: Rating Compant: Test Rater Date: _10—CA� 10/23/2018 8:46 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4 i 2017 - AIR BARRIER AND IN; d�ATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: . DAVENPORT RESIDENCE Builder Name: Street: LOT #35 OCEAN RESORT Permit Office: City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Y Owner. Jurisdiction: w Design Location: FL, Fort Pierce � COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. - Ceiling/attic The air barrier in any dropped ceiling/soffit. shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with'the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be out to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa. s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the Building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring J Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and. tubs shall. on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between a in addition ins ectian fire 4%pri6kier and wallq or cpflinris- of to it h 11 b ' p towa s s a e in accordance with the provisions of ICC-400. 10/23/2018 8:46 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD( - ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 78 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 2. Single-family or multiple -family 2. Single-family b) Return ducts R c) AHU location 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 35.2 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER 18.0 c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 956 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor.(weighted average) 7a. 0.294 b) Solar Heat Gain Coefficient (SHGC) 7b. 6.225 14. Heating system: Capacity 21.4 c) Area 7c. 210.5 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor(weighted'.average) 8a. -NA d) Gas furnace, natural gas AFUE b) Solar Heat ,Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9.40 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. b) Wood, raised. (R-value) 9b. 20.0 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior. d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank . EF 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery, unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11 a. 20.0 b) Cross ventilation No. b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e).Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed Fode compliant features. Builder Signature:, Address of New Home: Date: \ \ t% - 1 City/FL Zip: ST. LUCIE COUNTY, FL 10/23/2018 8:46:52 AM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 OFFICE USE ONLY: .�- �� DATE FILED: 4PERMIT # REVISION FEE: RECEIPT # C'Y' 1'2 0 PLANNING & DEVELOPMENT SERVIC S BUILDING & CODE REGULATION DIVISION - 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 610N (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION / LOCATION/SITE ��- e r r A YY) ADDRES S 12 kg - FEQ15YIdC ` DETAILED DESCRIPTION OF PROJECT S` &-%^iREVISIONS: Ve Y- kz Cl�i1M' I _- J l r CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: STATE: PHONE (DAYTIME): OWNER/BUILDER INFORMATION: NAME: ADDRESS: L\Ck A" a CITY: k (N-S , STATE: �D PHONE (DAYTIME: ARCHITECT/ENGINEER INFORMATION: NAME: M RV ADDRE S: 1 CITY: C V- 0 STATE: 4 PHONE (DAYTIME): q:l U � SLCCC: 9123109 Revised 06130117 File Copy P J-e-kg ST. LUCIE CO CERT. #: FAX: I FAX: ZIP: ZIP: RECEIVED' APR 2 0 2018 Permitting Department St. Lucie County, FL - - wrightsoft `Projei'�__Jummary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772466-6796 Email: \toe. d�3y Job: Date: Jun 26, 2017 By: For: DAVENPORT RESIDENCE LOT #35 OCEAN RESORT, ST. LUCIE COUNTY,ELRECEIVED�vo s: �' j 12'" •i i �unty, Permittin Weather:. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 12586 Btuh Structure 15122 Btuh Ducts 4087 Btuh Ducts 6118 Btuh Central vent (23 cfm) 701 Btuh Central vent (23 cfm) 375 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 17373 Btuh Use manufacturer's data n Rate/swin multiplier 0.95 Infiltration Equipment sensible load 20534 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2423 Btuh Ducts 1636 Btuh Central vent (23 cfm) 951 Btuh Heating Cooling Outside air Area (ft2) 956 956 Equipment latent load 5011 Btuh Volume (fP) 11387 11387 Air changes/hour 0.45 0.23 Equipment total load 25544 Btuh Equiv. AVF.(cfm) 85 44 Req. total capacity at 0.70 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make FUJITSU/HALCYON Make FUJITSU/HALCYON Trade Trade Model AOU36RLXFZ1 AHRI ref Cond AOU36RLXFZ1 Coil ASU18RFF+(2) ASU9RLF Efficiency 9.4 HSPF AHRI ref Efficiency 10.0 EER, 18 SEER Heating input Heating output 28600 Btuh @ 470F Sensible cooling Latent cooling 24640 10560 Btuh Btuh Temperature rise 27 OF Actual air flow 980 cfm Total cooling Actual air flow 35200 980 Btuh cfm Air flow factor 0.059 cfm/Btuh Static pressure 0.50 in H2O Air flow factor Static pressure 0.046 0.50 cfm/Btuh in H2O Space thermostat Capacitybalance point= 307 Load sensible heat ratio 0.81 Backup: Input = 5 kW, Output = .17342 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. w wrightsoft- Right -Suite® Universal2017 17.0.14 RSU08101 2018-Mar-2715:30:57// ...umentslDAVENPORT RESIDENCE-MNI SPIT SYSTEMS.rup Calc = MJ8 Front Door faces: N Paged wrightsoft l Righ- ,) Worksheet Job: Entire House Date: Jun 26, 2017 QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 Exposed wall 134.7 ft, 25.0 ft 3 Room height 11.9 ft d 9.0 ft heat/cool 4 Room dimensions 1.0 x 147.0 ft 5 Room area 955.5 ft' 147.0 ft' T y Construction U-value Or HTM Area ft' I Load I Area ft' I Load I number (Btuh/fN-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat c--,::] 6 try {L-pG_ .-.. - -- 13A-flocs _ - - - 0.143 - _, n -__.�- 4.00 2.55 ------- 324 _---- 288 _- ---- - - 1153 - - -- 733 - 0 -- -- 0 - - 0 - ._ .. 0 2 glazing, clr low-e 0.290 n 8.12 8.75 15 0 122 131 0 0 0 0 11D0 --- 0.390 - n_ .- IA92 .__-11.31 21 _-..-21 - _229 13A flocs 6.143 a 4.00 2.55 551 497 1990 1265 117 102 408 260 1 1 2 glazing, clr low-e 0.290 a 8.12 24.53 9 0 73 221 0 0 0 0 2 glazinq, clr low-e _.__-__0.290 --e-_ __ 8.12 ___24.53 45 _____0 _ 122 Vll 13A-4ocs 0.143 s 4.00 2.55 153 133 ____-365 5M ___1104 339 _____15 108 _____0 88 353 __368 225 2 glazing, clr low-e 0.290 s 8.12 8.75 5 5 39 42 5 5 39 42 lE��;` 2 glazing, clr low-e __. _ __ 0.290 -s_ --8.12 ____8.75 .�.- n 15 _____ 15 ______122 _____ 131 _____15 _ _ 15 - ______,122 _ __ __ 131. 0 13A-4ocs 0.143 sw 4.00 2.55 115 81 323 205 0 0 0 TW- 2 glazing, clr low-e 0.290 sw 8.12 18.88 5 0 38 88 0 0 0 0 VV�� 2 glazinq, clrlow-e 13A-4ocs _- _0.290 0.143 _sw. w __8.12 4.00 __,__18.88 2.55 _ • _-29 405 - 0 304 __-237 1216 551 773 _0 0 __0 0 __•___0 0 _. 0 0 2 glazing, clr low-e 0.290 w 8.12 24.53 5 0 38 114 0 0 6 0 2 glazing, clr low-e 0:290 w 8.12 24.53 15 0 122 368 0 0 0 0 2 glazing, clr low-e ___ _ _. _ _ 0.310' . -w__ . _ _ 8.68 ___ _22.91 __ _ _ _.82 _ _ _. __ -0 _ __ __ 708 __ _- _1869 ______0 ____ _.0 _ - 0 _______0 C - - 16B-19md -_ - _ _ . -_.--0.049 __- _._ 1.37 _____2.57 -__ _ 956 _ _._ -.956 ___1311 ___2458 ____ t4.7 _ 147 _ ___202 _ _ __ 378 F - ._ 20P-19t _ __. ._____.0.050 -_-_ _1.40. .__.0.63 _ ._.__ 956 _ _-_956 __. _1338 .____597 ___.__147 -__-_.147 _ -_206 -__ ---- 42 61 c) AED excursion 484 1 1 1 45 Envelope loss/gain 1 9958 11712 1 1 1452 1451 12 j a) Infiltration 2628 720 382 105 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 0 0 Appliances/other 2000 0 Subtotal (lines 6 to 13) 12586 15122 1834 1555 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 12586 15122 1834 1555 15 Duct loads 32% 40% 4087 6118 32% 40% 595 629 Total room load 16672 21239 2429 2184 Air required (cfm) I I I 980I 980I I I 143I 101 Calculations anDroved by ACCA to meet all requirements of Manual J 8th Ed „` vyrjghi�pitt- 2018-Mar-2715:30:57 Right -Suite® Universal2017 17.0.14 RSU08101 Page 1 uments\DAVENPORT RESIDENCE-MNI SPIT SYSTEMS.rup Calc = MJ8 Front Door faces: N wrightsoft� Right_. ) Worksheet Job: Entire House Date: Jun 26, 2017 QUICK CALLS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-8799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name KITCHEN LIVING 2 Exposed wall 13.0 ft 54.0 ft 3 Room height 14.0 ft heat/cool 14.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 237.5 ft 237.5 ft' 1.0 x 320.0 ft 320.0 ft2 Ty Construction U-value Or HTM I Area (ft2) I Load Area (ft2) Load number (Btuh/Wt - F (Btuh/ft') or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vll 134-40cs 0.143 n 4.00 2.55 0 0 0 0 252 216 865 55 0 2 glazing, clr low-e 0.290 n 8.12 8.75 0 0 0 0 15 0 122 131 I�_pG 11130,_--.__ __- .0.390 _n __-1192 11.31 .. _ --- 0 0 21 13A-4ocs 0.143 a 4.00 2.55 _ -0 182 - - 173 - - - -0 693 440 _.-._.. 252 .. __.21 222 - - --229 889 _238 565 11 2 glazing, clr low-e 0.290 a 8.12 24.53 9 0 73 221 0 0 0 0 2 glazinq. clr-low-e-_ ____.__0.290 _e_- --8.12 __ 24.53 0 .............4 .- __ _- w-� - _ 0 0 0 ^ 0 0 0 2 glazing, clr low-e 0.290 s 8.12 8.75 0 0 0 0 0 0 0 0 2glazing, clr,low,e ___._0.290 ,_s -__8.12 __8.75 -_-_-0 0 __.-__.0 -e__..__0 -. ---_0 0 0 13A-40cs 0.143 sw 4.00 2.55 0 0 0 0 0 0 _ 0 .___ _._0 0 T-_G 2 glazing, clr low-e 0.290 sw 8.12 18.88 0 0 0 0 0 0 0 0 2 glazinq, clr low-e -__ _- _0.290 sw. --8.12 _ 18.88 0 0 0 VL�13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 252 __ 170 682 434 2 glazing, clr low-e 0.290 w 8.12 24.53 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.290 w 8.12 24.53 . 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.310 _w 8.68 _ .22.91. _ 0 ._ 0 _. __ -.708 _ - _ 1869 C -_,- 168-19md...- -_ -.--0.049 _-_1.37 _ __2.57 238 ____•238 326 617 ..___._ 320 -320 ___---439 F - _ , 20P-19t - _ . _. _ _ _..._ 0.050 _ 1.40 _0.63 - ._- 238 _. _ 238 332 . _ _. 148 _ - _ 320 320 -_. _ _ 448 -`-,_823 . _ _ - 200 61 c) AED excursion 1 -681 1 1 1 221 Envelope loss/gain 1424 1353 1 1 4626 5766 12 a) Infiltration 309 85 1284 352 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 2000 0 Subtotal (lines 6 to 13) 1733 3437 5910 6578 Less external load 0 0 0 0 Less transfer Redistribution 0 0 0 0 0 0 0 0 14 Subtotal 1733 3437 5910 6578 15 Duct loads 32% 40% 563 1391 32% 40% 1919 2661 room load Air 22161351 42238281 74608291 923 requi dal (cfm) I I I I I 426I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t wrigF>ttsoft� 2018-Mar-2715:30:57 Rig ht-Suite@ Universal 2017 17.0.14 RSU08101 Page 2 uments\DAVENPORT RESIDENCE-MNI SPIT SYSTEMS.rup Calc = MJ8 Front Door faces: N +wrightsoft Righ& Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax: 772466-6796 Email: QUICKCALCS@AOL.COM Job: - Date: Jun 26, 2017 By: 1 Room name BATH BEDROOM 2 2 Exposed wall 18.0 ft 24.7 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 10.0 x 8.0 ft 1.0 x 171.0 ft 5 Room area 80.0 fN 171.0 ft2 T y Construction U-value Or HTM Area fe' Load Area ft' I Load I number (Btuh/ft'-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 (-G 13A1{ocs 0.143 n 4.00 2:55 72 72 288 183 0 6 2 glazing, clr low-e 0.290 n 8.12 8.75 0 0 0 0 0 0 0 0 11130 _ _._ ... .__. 0.390 _n. 10.92 -_ 11.31, - -, a , _ 0 0 ___ 0 V 13A-4acs 0.143 a 4.00 2.55 0 6 0 0 0 0 0 0 1 1 �G 2 glazing, clr low-e 0.290 a 8.12 24.53 0 0 0 0 0 0 0 0 _._ 2 olazinq. clr low-e. -- ------- 0.290 ..-e - ____8.12 __._24.53 _v. _ .__.0 ___0 _____0 . ____.____0 ._._ .. -0 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 _0 45 45 180 115 2 glazing, clr low-e 0.290 s 8.12 8.75 0 0 0 0 0 0 0 0 _.. -. 2glazing, cirlow-e _ ._ 0.290 s _ ___ 8.12 .._-:8.75 _r>._0 _._. ,._...0 ___-,_ _0 ._ _-__,_0 -0 ._-___-_0 .._0 13A-40cs 0.143 sw 4.00 2.55 0 0 0 0 115 81 323 205 2 glazing, clr low-e 0.290 sw 8.12 18.88 0 0 0 0 5 0 38 88 ___._... 2glazinq..clrlow-e-___.,- _- _0.290 sw _._8.12 ___ 18.88 __,__,__0 ___-_,0 __0 ___ _-0 _ _ _ 29 _ __ 0 _ ___ _ 237 _ 551 vb13A4ocs 0.143 w 4.00 2.55 90 85 342 217 _ 63 - 48 192 122 2 glazing, clr low-e 0.290 w 8.12 24.53 5 0 38 114 _ 0 0 0 0 2 glazing, clr low-e 0.290 w 8.12 24.53 0 0 0 0 15 0 122 368 2 glazing, clr low-e .__ __0.310 w_ 8.68 _ _.22.91 ..._ __. , _0 _­__0 _ _ __0 __ __._.0 __ __- _0 C_-__ 16B-19md ___ ______0.049 ___ -1.37 .___.2.57 80 .__..__.80 _____110 ...___206 __-__-_171 171 __. 235 _ __ 440 F _.:._ _ 20P-lgt-__ ._r0.050 _u ___1.40 , ,._0.63 ... .._.-_:80 -._�.80 _ __w112 ___._-_50 - _..- 171 __. 17i ._____239 107 6 c) AED excursion 301 1 1 346 Envelope loss/gain 1 890 800 1 1 1566 2342 12 a) Infiltration I 275 75 378 103 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 1165 876 1944 2675 Less external load 0 0 0 0 Less transfer 0 0 0 0 14 Redistribution Subtotal 0 1165 0 876 0 1944 0 2675 15 Duct loads 32% 40% 378 354 32 % 40% 631 1082 Total room load I 1543 1230 2575 3758 Air required (cfm) I I 91 I 57I I I 151 I 173I Calculations awroved by ACCA to meet all requirements of Manual J 8th Ed A. wt'Igi7#9oft' 2018-Mar-2715:30:57 Right -Suite® Universal 2017 17.0.14 RSU08101 Page ... umentslDAVENPORT RESIDENCE-MNI SPIT SYSTEMS.rup Calc = MJ8 Front Door faces: N