HomeMy WebLinkAboutBLOWER DOOR ANALYSIS REPORTRECEIVED
APR 15 2019
5T. Lucie County, Permitting
BLOWER DOOR ANALYSIS REPORT
FOR
Knowles Residence
3800 Anacostia Place
Ft. Pierce, FL 34949
Permit: 1706-0228
CONTRACTOR Millers Central Air. Inc.
ARCHITECT, Not Applicable ENGINEER - Not Applicable
CERTIFICATION
Air distribution system has been completely balanced as per requirements of
specifications and results of tests herein listed. Test and balance warranty one year.
Certification No. 10506
by Orlando Test and Balance, Inc.
Date April 23, 2019 Approved B.) yu"
D. James Haddick
Orlando Test and Balance, Inc.
Testing, Adjusting and Balancing of Air Conditioning, Ventilating and Heating Systems
P.O. Box 781227
Sebastian, FL 32958
Toll Free 877-675-3582
0 Orlando Test and Balance, Inc.
Orlando Test & Balance, Inc. INSTRUMENT LIST
Testing, Adjusting and Balancing Air Conditioning, Ventilating and Heating Systems PHONE 877-675-3582
TO,
Air Data Meter
Shortridge
ADM 870
50 - 8000 F.P.M.
0.001" - 50:0" H2O
Micromanometer
Alnor
AXD 550
179 - 17910 F.P.M.
0.002" - 20.0" H2O.
Balometer
Alnor
6463
0 - 2000 C.F.M.
Flow Hoods
Alnor
2x2 2x4 lx4
0 - 2000 C.F.M.
Thermal Anemometer
Dwyer
470-1
0 - 6000 F.P.M.
Florite
Bacharach
16-7001
0 - 1000 F.P.M.
Florite
Bacharach
16-7002
0 - 3000 F.P.M.
Ma nehelics
Dwyer
5 gauges
0 - 5.0" H2O
Vel rid
Shortridge
ADM 870
50 - 2500 F.P.M.
Airfoil
Shortridge
ADM 870
50 - 2500 F.P.M.
Pitot Tubes
Shortridge
18" - 36"
0 - 8000 F.P.M.
T>ACHOIVYET)�25
Optical / Digital
Ametek
1726
6 - 99,999 R.P.M.
Digital Infrared
Tif
780
80 - 20,000 R.P.M.
Contact
Stewart -Warner
Dial
50 - 4000 R.P.M.
TEMPERATURESENSING,
Electronic Quad Probe
Control Systems
T-100
-50 to 300' Fahrenheit
Thermometers
Miller
Glass / Mercury
-30 to 120' Fahrenheit
Sling Psychrometer
Bacharach
12-7011
10 -100 RH
LLE,CTR A &�M
Digital Meter
Amprobe
ACD-10 Super
0.1 - 600 Volts
0.1 - 300 Amps
Analog Meter
Amprobe
Ultra
0.1 - 600 Volts
0.1 - 300 Amps
SYSTEMS, GO NR�O,
Notebook Computer
Compaq
Presario 1200-XL
Windows 98
"ROW<� `>n>tk r
S JS �. �n 1�3.�s. ry.i.t� a.i.';
Hydro Data Meter
Shortridge
HDM 300
0 - 300 PSI H2O
Analog Data Meter
Florida Hydronics
R-50IQ
0 - 50" H2O
Q Orlando Test and Balance, Inc.
Orlando Test & Balance, Inc. COVER LETTER
Testing, Adjusting and Balancing Air Conditioning, Ventilating and Heating Systems PHONE 877-675-3582
April 23, 2019
Knowles Residence
3800 Anacostia Place
Ft. Pierce, FL 34949
Building envelope was tested using a Minneapolis Blower Test and TEC DG-100 pressure and
flow gauge.
Sincerely,
Bjuml, dY,
Orlando Test and Balance, Inc.
P.O. Box 781227 • Sebastian, FL 32958
Toll Free 877-675-3582
0 Orlando Test and Balance, Inc.