Loading...
HomeMy WebLinkAboutBLOWER DOOR ANALYSIS REPORTRECEIVED APR 15 2019 5T. Lucie County, Permitting BLOWER DOOR ANALYSIS REPORT FOR Knowles Residence 3800 Anacostia Place Ft. Pierce, FL 34949 Permit: 1706-0228 CONTRACTOR Millers Central Air. Inc. ARCHITECT, Not Applicable ENGINEER - Not Applicable CERTIFICATION Air distribution system has been completely balanced as per requirements of specifications and results of tests herein listed. Test and balance warranty one year. Certification No. 10506 by Orlando Test and Balance, Inc. Date April 23, 2019 Approved B.) yu" D. James Haddick Orlando Test and Balance, Inc. Testing, Adjusting and Balancing of Air Conditioning, Ventilating and Heating Systems P.O. Box 781227 Sebastian, FL 32958 Toll Free 877-675-3582 0 Orlando Test and Balance, Inc. Orlando Test & Balance, Inc. INSTRUMENT LIST Testing, Adjusting and Balancing Air Conditioning, Ventilating and Heating Systems PHONE 877-675-3582 TO, Air Data Meter Shortridge ADM 870 50 - 8000 F.P.M. 0.001" - 50:0" H2O Micromanometer Alnor AXD 550 179 - 17910 F.P.M. 0.002" - 20.0" H2O. Balometer Alnor 6463 0 - 2000 C.F.M. Flow Hoods Alnor 2x2 2x4 lx4 0 - 2000 C.F.M. Thermal Anemometer Dwyer 470-1 0 - 6000 F.P.M. Florite Bacharach 16-7001 0 - 1000 F.P.M. Florite Bacharach 16-7002 0 - 3000 F.P.M. Ma nehelics Dwyer 5 gauges 0 - 5.0" H2O Vel rid Shortridge ADM 870 50 - 2500 F.P.M. Airfoil Shortridge ADM 870 50 - 2500 F.P.M. Pitot Tubes Shortridge 18" - 36" 0 - 8000 F.P.M. T>ACHOIVYET)�25 Optical / Digital Ametek 1726 6 - 99,999 R.P.M. Digital Infrared Tif 780 80 - 20,000 R.P.M. Contact Stewart -Warner Dial 50 - 4000 R.P.M. TEMPERATURESENSING, Electronic Quad Probe Control Systems T-100 -50 to 300' Fahrenheit Thermometers Miller Glass / Mercury -30 to 120' Fahrenheit Sling Psychrometer Bacharach 12-7011 10 -100 RH LLE,CTR A &�M Digital Meter Amprobe ACD-10 Super 0.1 - 600 Volts 0.1 - 300 Amps Analog Meter Amprobe Ultra 0.1 - 600 Volts 0.1 - 300 Amps SYSTEMS, GO NR�O, Notebook Computer Compaq Presario 1200-XL Windows 98 "ROW<� `>n>tk r S JS �. �n 1�3.�s. ry.i.t� a.i.'; Hydro Data Meter Shortridge HDM 300 0 - 300 PSI H2O Analog Data Meter Florida Hydronics R-50IQ 0 - 50" H2O Q Orlando Test and Balance, Inc. Orlando Test & Balance, Inc. COVER LETTER Testing, Adjusting and Balancing Air Conditioning, Ventilating and Heating Systems PHONE 877-675-3582 April 23, 2019 Knowles Residence 3800 Anacostia Place Ft. Pierce, FL 34949 Building envelope was tested using a Minneapolis Blower Test and TEC DG-100 pressure and flow gauge. Sincerely, Bjuml, dY, Orlando Test and Balance, Inc. P.O. Box 781227 • Sebastian, FL 32958 Toll Free 877-675-3582 0 Orlando Test and Balance, Inc.