HomeMy WebLinkAboutBLOWER DOOR TESTPlanning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method Date: 04 / 23 / 19 Permit #: 1706-0228 Contractor: Masterpiece Builders Job Address: 3800 Anacostia Place Construction: (x) New Construction — Complete ( ) Existing — After Addition House Infiltration Test Results CFM (50) = 2755 Volume = 53,290 ACH (50) = CFM (50) x 60 / Volume = 3.10 Passing results must be & ACH (50) or less SLC Climate Zone 2 Test Date: 04 / 23 / 19 Mechanical Ventilation required less than 3 ACH (0) Pass ( ) Fail FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name: Orlando Test and Balance, Inc Address: 11629 High Street, Sebastian, FL 32958 I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate Zone 2. Signature: Printed Name: ___XAMF,5 'f4P,t>1> ( cK License/Certification #: fr-6 & I q 01 1 is awarded to BPI ID# 5061491 1!.%;:;;S�i�,► who has successfully completed a comprehensive evaluation and is a certified 3infiltration ;Duct as of .March 30, 2018 Expires: 3/30/2021 A . .. Larry BPI Zarker Bruce DeMaine Chief Executive Of jtcer Chief Operating Officer SM BUILDING PERFORMANCE INS-TITUTE, INC.