HomeMy WebLinkAboutBOUNDARY TOPOGRAPHIC SURVEY & SITE PLAN/O PLAT K 19
NGS cM z-q B00 PAGE 8
94-77—A20 Npp� ----_ N 48°56'2tv;' E
J SS3� AqC 1142.55'
06
z
N
cfl z N
Cn
N
�<> o 0
O N 01
C
z OLD COASTAL CONSTRUCTION
CONTROL LINE z
ca I z NEW COASTAL CONSTRUCTION (PLAT BOOK 19, Page 8) c0 O
J u, CON, ROL LINE �
-P
u1 (PLAT BOOK 26, Page 26 0
TZ; .
RECCRDED 9-15-1988) - 0
z
`D cD
-1 r
C,
Z O
W
Co
J o z
No
V74°36 13'�-- __ - �So
E 1030.36 ) PLAT BOOK 19, PAGE 8 C° U
�— Cp N
'030.57' (M) � —_ '201.51' /M
PLAT BOOK 26, PAGE 26 --- ---- N�3°58'13"E 1201.30' M
NGS CM -----_ _ S69°06'00"W----
41.60'
94-77-A19
\-N(S CM
R•57
a A �
LOT 4
3 STORY CBS
�g
=1 RESIDENCE 13.55'
-+ LACONIC POOL DECK ----
oI
POOL
1= 154.24'
D o ,- 15.58'
< In SEAWARD MOST
o D BUILDING LINE
67.64' - OVERHANG
----------
7 TROUGH
--- - ----- TROUGH
LO
O NEW COASTAL CONSTRUCTION
Ln o CONTROL LINE
y (PLAT BOOK 26, Page 26 OLD COASTAL CONSTRUCTION
11' CONTROL LINE
I N Z I RECORDED 9-15-1988)
> o I o '. (PLAT BOOK 19, Page 8;
O
to BENCHMARK
_ _ a . ..�
-tD OcD 0.Q~-
.
MANHOLE
� EL
EV=5.45� � O O
�\ I D ANACOSTIA z.-�
�- ]vu. z
PLAT BOOK 43, PAGE 1
D SET 5/8 IR&C
�t r — .. D LB 4286 o T 6
CqC '� �� �I N=1118782.8148 (VACANT) Flood Zone
j0' 9S Z M I E=893309.9216
"AE-8"
2pw�� Rl�,yr o _cATv ,
�Sphq !�� YCC D PEDESTAL --------------------------- --i
LEGAL DESCRIPTION
Being all of Lot 7, according to the plat of
ANACOSTIA, as recorded in Plat Book 43, Page 1
of the Public Records of St. Lucie County, Florida.
Contains 0.832 acres more or less.
OWNERS NAME
RUSSELL J. KNOWLES AND LINDA M. KNOWLES
SITE ADDRESS
ANACOSTIA PLACE
LEGEND
C
DENOTES
CENTERLINE
(P)
DENOTES
PLAT DATA
(C)
DENOTES
CALCULATED FROM FIELD MEASUREMENTS
(D)
DENOTES
DEED DATA
FND
DENOTES
FOUND
LB
DENOTES
LICENSED BUSINESS
UE
DENOTES
UTILITY EASEMENT
PLS
DENOTES
PROFESSIONAL LAND SURVEYOR
IP
DENOTES
IRON PIPI-
EL
DENOTES
ELEVATION
CM
DENOTES
CONCREII MONUMENT
CON:='
DENOTES
CONCREII
IR&C
DENOTES
5/8" IRC�II ROD & CAP
ORB
DENOTES
OFFICIAL RECORDS BOOK
f
DENOTES
PLUS OR MINUS
No.
DENOTES
NUMBER
PK&D
DENOTES
P.K. NAIL AND DISK
No ID
DENOTES
NO IDENTIFICATION NUMBER
PRM
DENOTES
PERMANENT REFERENCE MONUMENT
A
DENOTES
WATER VALVE
eso
DENOTES
ELEVATION (TYPICAL)
N.A.V.D.
DENOTES
NORTH AMERICAN VERTICAL DATUM
NGS
DENOTES
NATIONAL GEODETIC SURVE1
-`�
DENOTES
DRAII",!AGE FLOW LINE
N.G. V.D.
DENOTES
NATIONAL_ GEODETIC VERTICAL DATUM
------------------
II
Pq V�NG .59 ' PED STAL N70'45'20"E 509.72'
3
kg 46 S.6> 5.48 i - ��6 01 i 00 1 83.28' i , 62 66 8. SS
+�---�..- CONCCli
SLAB SET 5/8 IR&C i i II
32.67 LB 4286 i
I30
N=1118843.2243 ts
i E=893482.9616 ,
PROPOSED PROPOSED I
o M4 -�SED - �? 3 STORY CBS I
colvc o �--- Flood Z
m� Ln STAIRS — r RESIDENCE COLUMNS o0 one
D r 2.83 GARAGE EL=6.00' o 'n ' f j PROPERTY OWNER'S
Cf) S � � 1. 6 7' 7 r-
m � 06 - '- z 2nd FLOOR EL=18.67' '� EASEMENT NO. 1 _ VE-11'
K D w x 0 6. I PER PLAT
M z S, ks32 0 �_ cD 3rd FLOOR EL=33.00' o 0 LOT 7 �8 1.; 7
z D d �r o 'YS 4 SCATTERED k 4k *1 IQ k8
m i b w PROPOSED ; _ 11 67' k6.11 > a ; 3 SEAGRAPES i 104 g2
PAVER.DRIVE£
I o� 2.83' D VEGETATION LINE
4 (SEA GRAPES) ;
---------------�-------- 6' BEACH I
z _ _ 6 rn --- ---
`' - 5' --- --- ----- -------------------1-------- I ACCESS EASEMENT
10,17' - - DUNE i I I PER PLAT (TYPICAL)
_ DUNE
a 8.67'rnn 52.71' ---- '��TOP DUNE TOE
-----� ;
CONC - N CONC----------------- I i VEGETATION LINE
CURB" 32.67' SLAB 3' WALKING i (SEA OATS)
k ELECTRIC CONC PATH i f
5•67 JUNCTION BOX J SLAB
4
25.00 .4 cn S 93 cn 183.28' — — -+— -- — -,— -- I — — -- —�- — — I
4 6 82 4.>3 22 / N70'45'20"E 505.00' 6
--SET 5/8 IR&C
LB 4286
OLD COASTAL CONSTRUCTION
FIRE HYDRANT CONTROL LINE FND 5 8 IR
^ ..'`WITH VALVE ; I I
CL IN CONC PAD PLAT BOOK 19, Page 8 NO ID /
^ NEW COASTAL CONSTRUCTION ( g )
I I o LBD4CMAG j49 NAIL a- CONTROL LINE ANACOSTIA 0.08 W, 0.26' S
0 o 0. 74' S 10
(PLAT BOOK 26, Page 26 PLAT BOOK 43, PAGE 1 M
N RECORDED 9-15-1988) LOT 8 N
r-� tY) I FND 5/8 IR&C
4"x4" CM (VACANT) rn rn r—EDC LB 8098
N ®SOUTH PLAT LIFE N N s SOUTH PLAT LINE
PLAT LINE
I
THOMAS P. KIERNAN SIGNATURE DATE
PROFESSIONAL SURVEYOR & MAPPER
FLORIDA CERTIFICATE NO. 6199
CULPEPPER & TERPENING, INC
CONSULTING ENGINEERS I LAND SURVEYORS
2980 SOUTH 25th STREET • FORT PIERCE, FLORIDA 34981
PHONE 772-464-3537 • FAX 772-464-9497 • www.ct-eng.com
151 SW FLAGLER AVENUE • STUART, FLORIDA 34994
PHONE 772-220-3376 • FAX 772-464-9497 • www.ct-eng.com
STATE OF FLORIDA CERTIFICATION No. IB 4286
-- REVISIONS•
-
BY
.........
GLM
DATE
.........
8-30-17
............. .....
ADDED CONVERSION FACTOR FROM N.A.V.D. TO N.,• V.D. TO NOTES
GRAPHIC SCALE
20 0 10 20
( IN FEET )
1 inch = 20 ft.
NOTES:
1) Not valid without the signature and the original raised seal of a Florida
Licensed Surveyor and Mapper.
2) Description shown hereon provided by the client and/or their agent.
3) The last date of field work was May 19, 2016.
4) Overall parcel contains 0.832 Acres, more or less.
5) Lands shown hereon were not abstracted by this office for right—of—ways,
Reservations, Agreements, and/or Easements of Record. Such information
should be cbtained and confirmed by others through appropriate title
verification.
6) Elevations shown hereon are in N.A.V.D. 1988 and are referenced
to the NGS benchmark 94-77—A19 having a published elevation of
2.92 feet. -o convert from N.A.V.D. 1988 TO N.G.V.D. 1929 add 1.49
feet.
7) Bearings shown hereon are relative to the centerline of Tract A,
Anacostia Place having a bearing of N19°14'40"W.
8) Underground utilities, utility services, foundations and improvements were
not located as a part of this survey.
9) By graphic plotting only, said described property is located within an area
having a Flood Zone Designation AE EL 8, VE EL 11, and lies within a
Coastal Barrier Resources System (CRBS) Area on Flood Rate Map
No.12111 CO192 J with a date of identification of February 16, 2012, in
St. Lucie County, State of Florida, which is the current Flood Insurance
Rate Map for the community in which said premises is situated.
10) Additions or deletions to survey maps; or reports by other than the
signing party or parties is prohibited without written consent of the
signing party or parties.
11) Horizontal coordinates are referenced to Florida East Zone 901, State
Plane Coorc'inate System of N.A.D. 83/90.
PROPOSED STRUCTURE HEIGHT
ROOF MIDPC:iv- = ___— ABOVE THE MINIMUM
FL)EP ELEVATION OF —_—__ (NAVD)
F"r A2CHITECUAL PLANS
I
4.63
273.89' 6.62
S,96,
2.S8 52.55
k
7 6> !; Q30
I
W
N
PLATTED MEAN HIG';-1
MEAN HIGH WATER LINE
WATER LINE
ELEV= 0.45' N.A.V.D. 1988
r71
LOCATED MAY 19, 2016
Ln
0 ELEVATION LINE
N.A.V.D. 1988
#
r
k6. SO
ks �g
4° >6kk 2.63
—0
k1. >g kS8
I
0
SEASONAL HIGH WATER
LINE
ELEV= 5.22'
N.A.V.D.
1988
N
LOCATED
MAY 19,
2016
r-�;
i� Ln'
�l
I�
ro: I
in
z
I
8.03
270. 92
S 3
9
I
2.4g
\0 >8
k
I4>2
190
r
I
I
i
I
l
BY
DATE
FIELD
..........................................
CALCS.
...............................
DRAWN
GLM
6-27-16
.......
DETAILED
...................................
CHECKED
..........................................
APPROVED
BOUNDARY TOPOGRAPHIC SURVEY
&: SITE PLAN
PREPARED FOR
MASTEMPIERCE BUILDERS
DATE: 06-27-2016
HORIZ. SCALE:1"=20'
VERT. SCALE: N \A
JOB No. 1 6— Q 6 1
SHEET 1 OF 1