Loading...
HomeMy WebLinkAboutFINAL AS-BUILT SURVEYNGS CM \ ebb 94-77-A20y':� N=1121821.253 7�S 36.AgC E=891404.676 009 00, 6 O Z � N N cD<> O O � z 00 4cr, NGS CM 94-77-A19 N=1118854.195 E=892208.514 N 74°36 13'`E j 0 03 36 p� PLAT BOOK 26, PAGE( 26 in w D N 0 Z Cn Ci C) -- OX� I rn I n > c� D _I n = D---j 0 I o D < < I (7 S0' ®ST> >> 20, wio Ri�jyT o pCq �sptiq � wq ycE 0 I w� Qz zw CONC CURB I 25.00 04.1 Z cD Cp c� CD J O N PLAT BOOK 19 N48°56' , PAGE g 26 E ^ 1142.55) z N N cD W co U N 00 O OLD COASTAL CONSTRUCTION - CONTROL LINE z NEW COASTAL CONSTRUCTION co 0 CONTROL LINE (PLAT BOOK 19, Page 8) Cn (PLAT BOOK 26, Page 26 o 00 S RECORDED 9-15-1988) 0 Z C �! N CTt C' z � O �So PLAT BOOK 19, PAGE 8 C° cri >�- cD N - - 1201.51' M Q? -------,-- N73*58'13"E 1201.30' P� S69'06'00"W-7 41.60' NGS CM R-57___ N=1119200.821 E=893402.174 LOT 4 I 3 STORY CBS RESIDENCE 13_55' CONIC POOL DECK POOL 154.24' 15.58' SEAWARD MOST BUILDING LINE OVERHANG 99.98'---------------67.64'--------------- - TROUGH ---------------------------99.98------------------------- �. 15.08' LO I � O NEW COASTAL CONSTRUCTION a CONTROL LINE w (PLAT BOOK26, Page 26 OLD COASTAL CONSTRUCTION M RECORDED 9-15-1988) CONTROL LINE (PLAT BOOK 19, Page 8) O o : O fl Q r7 cD r� OO �O z CERTIFICATIONS Russell and Linda Knowles Masterpiece Builders CenterState Bank, N.A. Fidelity National Title Insurance Company LEGAL DESCRIPTION Being all of Lot 7, according to the plat of ANACOSTIA, as recorded in Plat Book 43, Page 1 of the Public Records of St. Lucie County, Florida. Contains 0.832 acres more or less. RUSSELL J. KNOWLES AND LINDA M. KNOWLES SITE ADDRESS 3800 ANACOSTIA PLACE LEGEND - -� DENOTES DRAINAGE FLOW LINE (cy) DENOTES CUBIC YARDS N.A.V.D. DENOTES NORTH AMERICAN VERTICAL DATUM NGS DENOTES NATIONAL GEODETIC SURVEY C DENOTES CENTERLINE (P) DENOTES PLAT DATA (C) DENOTES CALCULATED FROM FIELD MEASUREMENTS (D) DENOTES DEED DATA FND DENOTES FOUND LB DENOTES LICENSED BUSINESS LIE DENOTES UTILITY EASEMENT PLS DENOTES PROFESSIONAL LAND SURVEYOR IP DENOTES IRON PIPE EL DENOTES ELEVATION CM DENOTES CONCRETE MONUMENT CONIC DENOTES CONCRETE IR&C DENOTES 5/8" IRON ROD & CAP ORB DENOTES OFFICIAL RECORDS BOOK t DENOTES PLUS OR MINUS No. DENOTES NUMBER PK&D DENOTES P.K. NAIL AND DISK No ID DENOTES NO IDENTIFICATION NUMBER PRIM DENOTES PERMANENT REFERENCE MONUMENT DENOTES WATER VALVE DENOTES EXISTING ELEVATIONS (TYPICAL) S0 DENOTES PROPOSED ELEVATIONS (TYPICAL) -6 DENOTES PROPOSED CONTOURS BENCHMARK ANACOSTIA STORM PLAT BOOK 43, PAGE 1 MANHOLE ELEV=5.45' LOT 6 Flood Zone - FND 5/8 IR&C (VACANT) "AE-8" FND 5/8 IR&C _LB 4286 LB 4286 N=1118782.8148 N=1118843.2243 E-893309.9216 APPROXIMATE SEAWARD EXTENT OF CONSTRUCTION 116.24' E=893482.9616 CATV ' -PEDESTAL N70'45'20"E 471.40' 183.28' � i AT&T CD , o i � o 50.43' ' PEDESTAL r I � i 5' CONC. WALK __ ------------------�- �i 13.1' --- �'� CONC.M 1.82' 54.9' i I o 1 CONC. `V IDRIVE ' w O i I D 42_-5-----__ 5.34' - 5.0'_�z 3 STORY C.B.S. 0 oLOT 72 ' 0 120 7.32 RESIDENCE`V059. 74' .58y'D _ _ _ _ _ _ I GARAGE EL=7.07'---------- , SCATTERED GROUND FLOOR EL=8.05' g20' SEAGRAPES .31'-n 1ST FLOOR EL=20.27' CO °' VEGETATION LINE ___42_63' N 2ND FLOOR EL=34.62z 5.5.0 z (SEA GRAPES) 33'^� CONIC. N C6 ov C6 DRIVE 10 2' __ m DUNE i DUNE r 44.66' 15.009.20' 52.22' TOP DUNE TOE ________ I i f VEGETATION LINE 5' CONIC. WALK Oi C) 1 3' WALKING %,_ (SEA OATS) O1 0 Oi PATH ELECTRIC �i �i 6 JUNCTION BOX 1 _J T� 183.28'-- N70'45'20"E 468.45' ' FND 5/8 IR&C FIRE HYDRANT 4286 OLD COASTAL CONSTRUCTION WITH VALVE CONTROL LINE FND 5/8 IR IN CONC PAD (PLAT BOOK 19, Page 8) NO ID NEW COASTAL CONSTRUCTION 0.08' w, 0.26' S FND MAG NAIL a CONTROL LINELB ANACOSTIA 0.74'1s9 I (PLAT BOOK 26, Page 26 PLAT BOOK 43, PAGE 1 N RECORDED 9-15-1988) LOT 8 N FND 5/8 IR&c r j 4"x4" CM (VACANT) 0) EDC LB 8098 CIA/-9 SOUTH PLAT LINE N N /-® SOUTH PLAT L_WE THOMAS P. KIERNAN PROFES31ONAL SURVEYOR Jc MAPPER FLORIDA CERTIFICATE NO. 6199 nel- if SIGNATURE DATE PL O� J cD N13'09'11 "W 77.12' N o0 0i.- NGS CM R-58 i Z N=1118164.191 E=893711.133 `b CULPEPPER & TERPENING, INC CONSUL TING ENGINEERS I LAND SURVEYORS 2980 SOUTH 25th STREET • FORT PIERCE, FLORIDA 34981 PHONU 772-464-3537 • FAX 772-464-9497 • www.ct-eng.com 151 S\V FLAGLER AVENUE • STUART, FLORIDA 34994 PHONE; 772-220-3376 • FAX 772-464-9497 • www.ct-eng.com STATE OF FLORIDA CERTIFICATION No. LB 4286 PROPERTY OWNER'S EASEMENT NO. 1 PER PLAT 6' BEACH ACCESS E PER PLAT �I 251.67' PLATTED MEAN HIGH WATER LINE �I Flood Zone "VE-11" -REVISIONS - BY DATE ............................................................................................................. ............................................................................................................. I - I I I I I I I GRAPHIC SCALE 20 0 10 20 ( IN FEET ) 1 inch = 20 ft. NOTES: 1) Not valid without the signature and the original raised seal of a Florida Licensed Surveyor and Mapper. 2) Description shown hereon provided by the client and/or their agent. 3) The last date of field work was April 18, 2019. 4) Overall parcel contains 0.809 Acres, more or less. 5) Lands shown hereon were not abstracted by this office for right-of-ways, Reservations, Agreements, and/or Easements of Record. Such information should be obtained and confirmed by others through appropriate title verification. 6) Elevations shown hereon are in N.A.V.D. 1988 and are referenced to the NGS benchmark 94-77-A19 having a published elevation of 2.92 feet. 7) Bearings shown hereon are relative to the centerline of Tract A, Anacostia Place having a bearing of N19°14'40"W. 8) Underground utilities, utility services, foundations and improvements were not located as a part of this survey. 9) By graphic plotting only, said described property appears to be located within an area having a Flood Zone Designation AE EL 8, VE EL 11, and lies within a Coastal Barrier Resources System (CRBS) Area on Flood Rate Map No.12111CO192 J with a date of identification of February 16, 2012, in St. Lucie County, State of Florida, which is the current Flood Insurance Rate Map for the community in which said premises is situated. No additional search of the public records has been performed. There may be additional map amendments affecting this property. 10) Additions or deletions to survey maps or reports by other than the signing party or parties is prohibited without written consent of the signing party or parties. 11) Horizontal coordinates are referenced to Florida East Zone 901, State Plane Coordinate System of N.A.D. 83/90. MEAN HIGH WATER LINE - ELEV= 0.45' N.A.V.D. 1988 LOCATED DECEMBER 01, 2016 SEASONAL HIGH WATER; LINE ELEV= 5.22' N.A.V.D. 1988 LOCATED DECEMBER 01, 2016 BY DATE FIELD .......................................... PK 4/18/19 CALCS. ............................... DRAWN ........................ JDJ 4/19/19 DETAILED .......................................... CHECKED .................................... APPROVED 36.45 w o d- co M! D n 0 ELEVATION LINE N.A.V.D. 1988 w G O N n to c1q fl- D 37.29' Final As -Built Survey PREPARED FOR MASTERPIERCE BUILDERS iECEIVEQ APR 15 2019 5T. Lwp.lp Cowncy, Permitting Iiq- 06.- DATE: 4/19 /19 HORIZ. VERT. SCALE:1"=20' SCALE: N\A JOB No. 16-061 SHEET 1. OF 1