Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION
to FItRZ � V IED L,ffl Load Short Form PA `Cal AHU-1 GrndFl 'Wc.. the.1.1.g piece' Job: Russell & Linda Knowles Date: Mar 10, 2017 By: Tom Platania ProCalcs, LLC PER!1M17TliiG St. Lucie County, FL P.O. Box882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project Information For: Russell & Linda Knowles Lot #7, Anacostia Place; Ft. Pierce, FL 34982 Design • Htg Clg Infiltration Outside db (°F) 39 92 ! Method Simplified Inside db (°F) 70 75 ! Construction quality Average Design TD (°F) 31 17 Fireplaces 1 (Average) Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/lb) 27 58 HEATING EQUIPMENT Make Mitsubishi Trade Mr. Slim Model PUMY-P48NHMUR4 AHRI ref 3017691 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 0 eF 8.7 HSPF 13500 Btuh @ 470F 39 °F 318 cfm 0.028 cfm/Btuh 0.60 in H2O COOLING EQUIPMENT Make Mitsubishi Trade Mr. Slim Cond PUMP P48NHMUR4 Coil PEFY P12NMAU-E3 AHRI ref 3017691 Efficiency 8.4 EER, 14.5 SEER Sensible cooling 9600 Btuh Latent cooling 2400 Btuh Total cooling 12000 Btuh Actual air flow 318 cfm Air flow factor 0.034 cfm/Btuh Static pressure 0.60 in H2O Load sensible heat ratio 0.88 ' ROOM NAME Area (ft2) ;Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) AHU1 CL 24 I 0 0 0 0 Art Studio 334 4313 3195 121 109 Cabana Bath 99 1173 626 33 21 Laundry 150 1217 998 34 34 Recreation 132 1087 1892 30 65 Storage 151 2804 1957 79 67 V t ')AA 753 630 21 22 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. e -i 0 1( 1W-10 15:49:36 �- wrightSOft® Right -Suite® Universal 2017 17.0.19 RSU17939 J Page 1 ACCA ...ed Finals\Knowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W s AHLI-1 GrndFl 1129 11346 9299 318 318 Other equip loads 0 0 Equip. @ 1.00 RSM 9299 Latent cooling 1228 TIITAI C 1170 112AL.` 1 r1G77 210 24 Q Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft° Right -Suite® Universal 2017 17.0.19 RSU17939 ACC-N ...ad Finals\Knowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W 2017-Mar-10 15:49:36 Page 2 r Load Short Form Job: Russell & Linda Knowles Date: Mar 10 2017 ,r wcarclhcmisaingpfttc AHU-2 SecFlr By: Tom Platania ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www. ProC ales. Net License: CAC1815254 RTIN #0105474 Project• • For: Russell & Linda Knowles Lot V, Anacostia Place, Ft. Pierce, FL 34982 Design Information Htg Clg Infiltration Outside db (OF) 39 92 Method Simplified Inside db (OF) 70 75 Construction quality Average Design TD (OF) 31 17 Fireplaces 1 (Average) Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/lb) 27 58 HEATING EQUIPMENT Make Mitsubishi Trade Mr. Slim Model PUMP P48NHMUR4 AHRI ref 3017691 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 0 OF 8.4 HSPF 34000 Btuh @ 47°F 42 OF 742 cfm 0.035 cfm/Btuh 0.60 in H2O COOLING EQUIPMENT Make Mitsubishi Trade Mr. Slim Cond PUMP P48NHMUR4 Coil PEFY 30NMAU-E3 AHRI ref 3017691 Efficiency 8.4 EER, 14.5 SEER Sensible cooling 24000 Btuh Latent cooling 6000 Btuh Total cooling 30000 Btuh Actual air flow 742 cfm Air flow factor 0.030 cfm/Btuh Static pressure 0.60 in H2O Load sensible heat ratio 0.87 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) CIg AVF (cfm) 2nd Flr Stairs 176 2788 1769 97 53 Bath 1 65 621 576 22 17 Bath 2 75 594 561 21 17 Bedroom 1 228 3087 2637 107 78 Bedroom 2 171 2401 2232 83 66 Gallery 244 1089 2238 38 66 Grt Rm Ktchn Dnng 948 10393 14544 360 432 Pantry 46 0 0 0 0 WIC 1 45 61 323 2 10 \Alrrr' 7 A4 lag OA 12 12 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Mar-10 15:49:36 „1 wrightsoft° Right Universal 2017 17.0.19 RSU17939 Page 3 A.CK ...ad Finals\Knowles Residence Revised Final 3.rup Cale = MJ8 Front Door faces: W Ip AHU-2 SecFlr 2039 21399 24975 742 742 Other equip loads 0 0 Equip. @ 1.00 RSM 24975 Latent cooling 3635 Tl1TA1 C 7/14In 744a0 7QQ4A 7A7 7A7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightSOW Right -Suite® Universal 2017 17.0.19 RSU17939 ACACK ...ad Finals\Knowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W 2017-Mar-10 15:49:36 Page 4 v Am Load Short Form Job: Russell & Linda Knowles r rA—lic•7 Date: Mar 10, 2017 w�a�athcm4ringpkcc'iAHU-3 Master 3rd By: Tom Platania ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project• • For: Russell & Linda Knowles Lot #7, Anacostia Place, IFt. Pierce, FL 34982 Design Information Htg Clg Infiltration Outside db (OF) 39 92 Method Simplified Inside db (OF) 70 75 Construction quality Average Design TD (OF) 31 17 Fireplaces 1 (Average) Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/lb) 27 58 HEATING EQUIPMENT Make TRANE Trade TRANE Model BAYHTR1408BRKA AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 8.0 kW 27297 Btuh 94 OF 263 cfm 0.012 cfm/BtuN 0.60 in H2O COOLING EQUIPMENT Make Trane Trade TRANE Cond 4TTR4037L1 Coil TEM6AOC42H41++TDR AHRI ref 7567547 Efficiency 13.0 EER, 16 SEER Sensible cooling 27840 Btuh Latent cooling 6960 Btuh Total cooling 34800 Btuh Actual air flow 1160 cfm Air flow factor 0.040 cfm/Btuh Static pressure 0.60 in H2O Load sensible heat ratio 0.86 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) 3rd Fir Stairs 152 1700 1656 20 66 Her Closet 182 2717 3865 32 155 Her Master Bath 245 3216 2713 38 109 Her WC 24 42 208 0 8 His Closet 98 663 431 8 17 His Master Bath 182 2894 4023 34 161 His WC 24 42 244 0 10 Master Bedroom 295 6017 7605 70 304 Master Laundry 94 164 1323 2 53 Master Vest 230 1765 1977 21 79 cua;..,. I)cc 12071) AQrQ as lost Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Mar-10 15:49:36 wrightsoft° Right -Suite® Universal 2017 17.0.19 RSU17939 Page 5 ACCK ...ed FinalslKnowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W w I. AHU-3 Master 3rd 1780 22491 29005 263 1160 Other equip loads 0 0 Equip. @ 1.00 RSM 29005 Latent cooling. 4650 T!'1TA1 C 470r% 77A01 122a9 r. Oa Ilan Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ,� + wrightsoft® Right -Suite® Universal 2017 17.0.19 RSU17939 ACCP.... ed Finals\Knowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W 2017-Mar-10 15:49:36 Page 6 Buildi n Anal SIS Job: Russell & Linda Knowles `g wWe Qcalsing " AHU-1 GmdFly Byte. TTomMar'P1 tan a ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 For: Russell & Linda Knowles Lot #7, Anacostia Place, Ft. Pierce, FL 34982 Design Conditions Location: Indoor: Heating Cooling Vero Beach Muni, FL, US Indoor temperature (OF) 70 75 Elevation: 30 ft Design TD (OF) 31 17 Latitude: 28ON Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 27.1 57.7 Dry bulb (OF) 39 92 ' Infiltration: Daily range (OF) - 15 (L ) Method Simplified Wet bulb (OF) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Component Btuh/ft2 Btuh % of load Walls 3.4 4224 137.2 Glazing 14.1 1727 15.2 Doors 12.2 586 5.2 Ceilings 0 0 0 Floors 2.3 2585 22.8 Infiltration 2.4 2224 19.6 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 11346 ,100.0 Component Btuh/ft2 Btuh % of load Walls 1.4 1780 19.1 Glazing 19.7 2410 25.9 Doors 11.8 567 6.1 Ceilings 0 0 0 Floors 0 0 0 Infiltration 0.6 568 6.1 Ducts 0 0 Ventilation 0 0 Internal gains 3975 42.7 Blower 0 0 Adjustments 0 Total 9299 100.0 Latent Cooling Load = 1228 Btuh Overall U-value = 0.114 Btuh/ft2-OF Data entries checked. Infiltration Walls -e Floors Glazing Doors Glazinc Doors Intlltratlon nternal Gains Wrl htsoft° 2017-Mar-10 15:age 1 g Right -Suite® Universal 2017 17.0.19 RSU17939 Page 1 ACCN ...ad FinalsWnowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W Building Analysis Job: Russell & Linda Knowles g Y Date: Mar 10, 2017 AHU-2 SecFlr y ti 'Wearou,emlaingpiccc' B Tom Platania ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmaii.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 For: Russell & Linda Knowles Lot #7, Anacostia Place, Ft. Pierce, FL 34982 Design Conditions Location: Indoor: Heating Cooling Vero Beach Muni, FL, US Indoor temperature (OF) 70 75 Elevation: 30 ft Design TD (OF) 31 17 Latitude: 280N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 27.1 57.7 Dry bulb (OF) 39 92 Infiltration: Daily range (OF) - 15 (L ) Method Simplified Wet bulb (OF) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Component Btuh/ft2 Btuh % of load Walls 3.0 5460 25.5 Glazing 14.1 6259 29.2 Doors 0 0 0 Ceilings 9.0 2336 10.9 Floors 2.4 2209 10.3 Infiltration 2.4 5136 24.0 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 21399 - 100.0 Component Btuh/ft2 Btuh % of load Walls 1.2 2273 9.1 Glazing 27.9 12385 49.6 Doors 0 0 0 Ceilings 18.6 4835 19.4 Floors 0 0 0 Infiltration 0.6 1311 5.2 Ducts 0 0 Ventilation 0 0 Internal gains 4170 16.7 Blower 0 0 Adjustments 0 Total 1 24975 100.0 Latent Cooling Load = 3635 Btuh Overall U-value = 0.159 Btuh/ft2-OF Walls Infiltration Floors Glazing Ceilings Glazing WARNING: suspicious slab -on -grade floor perimeter in 2nd Fir Stairs. WI'1 I1tSQft° 2017-Mar-1015:49:36 �- 9 Right -Suite® Universal 2017 17.0.19 RSU17939 Page 2 ACCN ...ed Finals\Knowles Residence Revised Final 3.rup Cale = MJ8 Front Door faces: W BuildingAnalysis Job: Russell & Linda Knowles Y Date: Mar 10, 2017 U�Q`CaICS AHU-3 Master 3rd By: Tom Platania i We arc the WSIMg ptem* ProCalcs, LLC P.O. Box882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project• • For: Russell & Linda Knowles Lot #7, Anacostia Place, Ft. Pierce, FL 34982 Design Conditions Location: Indoor: Heating Cooling Vero Beach Muni, FL, US Indoor temperature (OF) 70 75 Elevation: 30 ft Design TD (OF) 31 17 Latitude: 280N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 27.1 57.7 Dry bulb (OF) 39 92 Infiltration: Daily range (OF) - 15 (L ) Method Simplified Wet bulb (OF) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Heatin Component, Btuh/ft2 Btuh % of load Walls 3.0 4590 20.4 Glazing 14.1 6028 26.8 Doors 0 0 0 Ceilings 1.4 2451 10.9 Floors 3.7 6 0.0 Infiltration 2.4 4716 21.0 Ducts 4700 20.9 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 22491 100.0 Component Btuh/ft2 Btuh % of 'load Walls 1.2 1925 6.6 Glazing 29.5 12634 43.6 Doors 0 0 0 Ceilings 2.4 4214 14.5 Floors 2.0 3 0.0 Infiltration 0.6 1204 4.2 Ducts 6555 22.6 Ventilation 0 0 Internal gains 2470 8.5 Blower 0 0 Adjustments 0 Total 29005 100.0 Latent Cooling Load = 4650 Btuh Overall U-value = 0.111 Btuh/ft2-OF Data entries checked. Glazi Glazing Ceilings "�.. wri htsoft' 2017-Mar-1015:49:36 �+ g Right -Suite® Universal 2017 17.0.19 RSU17939 Page 3 ACiC% ...ad Finals\Knowies Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W i i 7� Project Summary Job: Russell & Linda Knowles d: �9p ; �Q3 Caks Y Date: Mar 10, 2017 `tom, U LJir® `r AHV-1 GmdF1 By: Tom Platania �_ 'We are the mLting ptecc' ProCalcs, LLC P.O. Box882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 For: Russell & Linda Knowles Lot #7, Anacostia Place, Ft. Pierce, FL 34982 Notes: N2 Architecture & Design 2081 SE Ocean Blvd. Stuart, Florida 34997 Design Information Weather: Vero Beach Muni, FL, US Winter Design Conditions Outside db 39 OF Inside db 70 OF Design TD 31 OF Heating Summary Structure 11346 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 11346 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 1 (Average) Heating Cooling Area (ft2) 1129 1129 Volume (ft3) 11293 11293 Air changes/hour 0.34 0.17 Equiv. AVF (cfm) 65 31 Heating Equipment Summary Make Mitsubishi Trade Mr. Slim Model PUMY-P48NHMUR4 AHRI ref 3017691 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 0 OF 8.7 HSPF 13500 Btuh @ 470F 39 OF 318 cfm 0.028 cfm/Btuh 0.60 in H2O Summer Design Conditions Outside db 92 OF Inside db 75 OF Design TD 17 OF Daily range L Relative humidity 50 % Moisture difference 58 gr/lb Sensible Cooling Equipment Load Sizing Structure 9299 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Equipment sensible load 9299 Btuh Latent Cooling Equipment Load Sizing Structure 1228 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 1228 Btuh Equipment total load 10527 Btuh Req. total capacity at 0.80 SHR 1.0 ton Cooling Equipment Summary Make Mitsubishi Trade Mr. Slim Cond PUMY-P48NHMUR4 Coil PEFY P12NMAU-E3 AHRI ref 3017691 Efficiency 8.4 EER, 14.5 SEER Sensible cooling 9600 Btuh Latent cooling 2400 Btuh Total cooling 12000 Btuh Actual air flow 318 cfm Air flow factor 0.034 cfm/Btuh Static pressure 0.60 in H2O Load sensible heat ratio 0.88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri Ih't:Sdit° 2017-Mar-1015:49:36 g Right -Suite® Universal 2017 17.0.19 RSU17939 Page 1 ACCP.... ed Finals\Knowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W v ,/01- Project Summary 1Yt� AHU-2 SecFlr V We arc the misting piece ProCaics, LLC Job: Russell & Linda Knowles Date: Mar 10, 2017 By: Tom Platania P.O. Box 882032. Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project• • For: Russell & Linda Knowles Lot #7, Anacostia Place, Ft. Pierce, FL 34982 Notes: N2 Architecture & Design 2081 SE Ocean Blvd. Stuart, Florida 34997 Weather: Vero Beach Muni, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 70 °F Inside db 75 °F Design TD 31 °F Design TD 17 °F Daily range L Relative humidity 50 % Moisture difference 58 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21399 Btuh Structure 24975 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21399 Btuh Use manufacturer's data y Rate/swing multiplier Equipment load 1.00 24975 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 3635 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating coolingg (none) Area (ft2) 2039 2039 Equipment latent load 3635 Btuh Volume (ft3) 23642 23642 Air changes/hour 0.38 0.18 Equipment total load 28610 Btuh Equiv. AVF (cfm) 149 72 Req. total capacity at 0.80 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make Mitsubishi Make Mitsubishi Trade Mr. Slim Trade Mr. Slim Model PUMY-P48NHMUR4 Cond PUMP P48NHMUR4 AHRI ref 3017691 Coil PEFY 30NMAU-E3 AHRI ref 3017691 Efficiency 8.4 HSPF Efficiency 8.4 EER, 14.5 SEER Heating input Sensible cooling 24000 Btuh Heating output 34000 Btuh @ 47°F Latent cooling 6000 Btuh Temperature rise 42 °F Total cooling 30000 Btuh Actual air flow 742 cfm Actual air flow 742 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.030 cfm/Btuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.87 Capacity balance point = 0 °F Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. r Wrl htSOft° 2017-Mar-1015:49:36 9 Right -Suite® Universal 2017 17.0.19 RSU17939 Page 2 ACCN ...ad Finals\Knowles Residence Revised Final 3.rup Calc = 10J8 Front Door faces: W Pro ect Summary Job: Russell & Linda Knowles *�� n: %��y'/e Date: Mar 10, 2017 ` we are the rhiaina piece'S AHU-3 Master 3rd By: Tom Platania ProCalcs, LLC P.O. Box882032, PortSaint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www. ProCalcs. Net License: CAC1815254 RTIN #0105474 Project Information For: Russell & Linda Knowles Lot #7, Anacostia Place, Ft. Pierce, FL 34982 Notes: N2 Architecture & Design 2081 SE Ocean Blvd'. Stuart, Florida 34997 Design Information Weather: Vero Beach Muni, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 92 OF Inside db 70 OF Inside db 75 OF Design TD 31 OF Design TD 17 OF Daily range L Relative humidity 50 % Moisture difference 58 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17792 Btuh Structure 22449 Btuh Ducts 4700 Btuh Ducts 6555 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 22491 Btuh Use manufacturer's data y Rate/swing multiplier Equipment load 1.00 Btuh Infiltration sensible 29005 Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2603 Btuh Ducts 2047 Btuh Central vent (0 cfm) 0 Btuh Heating Coolingg (none) Area (ftZ) 1780 1780 Equipment latent load 4650 Btuh Volume (ft3) 18760 18760 Air changes/hour 0.44 0.21 Equipment total load 33655 Btuh Equiv. AVF (cfm) 137 66 Req. total capacity at 0.80 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make TRANE Make Trane Trade TRANE Trade TRANE Model BAYHTR1408BRKA Cond 4TTR40371_1 AHRI ref Coil TEM6AOC42H41++TDR AHRI ref 7567547 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 8.0 kW Sensible cooling 27840 Btuh Heating output 27297 Btuh Latent cooling 6960 Btuh Temperature rise 94 OF Total cooling 34800 Btuh Actual air flow 263 cfm Actual air flow 1160 cfm Air flow factor 0.012 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrl f7tSOf * 2017-Mar-1015:49:36 9 Right -Suite® Universal 2017 17.0.19 RSU17939 Page 3 ACC4+.... ad FinalslKnowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W Z%f"C�+' pp,,.�, RI ht-JO Worksheet Job: Russell &Linda Knowles al� Date: Mar 10, 2017 AHU-1 GmdF1 By: Tom Platania ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name AHU-1 GmdFI AHU1 CL 2 Exposed wall 70.0 ft 0 ft 3 Room height 10.0 ft 10.0 ft heat/cool 4 Room dimensions 8.0 x 3.0 ft 5 Room area 1129.3 ftz 24.0 ftz Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft� Area (ft� or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 4A5-2ob 4B5-2fb 0.095 0.450 0.450 n n n 2.97 0.00 14.08 1.25 0.00 13.71 190 0 30 160 0 0 476 0 423 200 0 411 0 0 0 0 0 0 0 0 0 0 0 0 11 4B5-2fb 4B5-2fb 0.450 0.450 n .n 0.00 0.00 0.00 .. _0.00 0 :_ -0 0 _ _ 0 0 _ 0. 0 _ . 0 0 0 0 _0 0 0 0 _ _ 0 _ 13A-7.5ocs 10D-b 0.095 0.450 a a 2.97 0.00 1.25 0.00 410 0 356 0 1059 0 444 0 0 0 0 0 0 0 0 0 1OD-b 0.450 a 14.08 19.60 24 48 338 470 0 0 0 0 4A5-2ob 4A5-2ob 0.450 0.450 a a 14.08 0.00 23.71 0.00 10 0 20 0 141 0 237 0 0 0 0 0 0 0 0 0 4A5-2obd 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 'e 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 14.08 23.71 20 40 282 474 0 0 0 0 W 13A-7.5ocs 0.095 s 2.97 1.25 _ 100 61 183 _ _ 77 0 _ 0 0 0 1OD-b 4A5-2ob 0.450 0.450 s s 14.08 0.00 19.60 0.00 24 0 48 0 338 0 470 0 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 4A5-2ob 0.450 0.450 s s 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4B5-2fb 4B5-2fb 0.450 0.450 s s 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08 23.71 15 29 205 346 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4135-2fb 0.450 s 0.00 _ 0.00 0 0 0 0 0 0 0. 0 W Partition Wall 0.144 s 4.51 2.82 , 100 100 451 282 0 0 0 0 W 13A-7.5ocs 0.095 w 2.97 1.25 !_ _ 130 130 387 _ 162 0 0 0 0 13A-7.5ocs 0.095 w 0.00 0.00 0 0 0 0 0 0 0 0 1OD-b 1OD-b 0.450 0.450 w w 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1OD-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 P 13A-7.5om 0.095 - 2.97 6.75 , 145 .145 431 _ 109 0 0 0 0 P Frm wall, r-11 cav i 0.144 - 4.52 1.70 30 30 135 51 0 0 0 0 R Partition Wall 0.144 - 4.51 1.70 _ 215 167 754 284 0 0 0 0 L_ 0 11 DO 0.390 n 12.21 _ _ 11.82 , 4.8 48 586 567 0 0 0 _ 0 P Partition Wall 0.101 - 0.00' 0.00 0 0 0 0 0 0 0 0 P Partition Wall 0.101 - 3.17 _ _ 1..56, 110 110 349 172 110 110 _ 349 172 C 16B-21md 0.044 0.00 0.00 0 0 0 0 0 0 0 0 C 17A-Ozd 0.287 _ - Q.00 _0.00 0 0 0 0 0 0 0 0 F 19A-Obstp 0.368 - 0.00 0.00 0 0 0 0 0 0 0 0 F F 22A-tpm 22A-tpm_ 1.180 1.180 - - 36.93 0.00 0.00 0.00 1129 0 70 0 2585 0 0 0 24 0 0 0 0 0 0 0 F Flrfloor, 1401b)ft 0.102 - 0.00 0.00 0 0 0 0 0 0 .0 0 F Flrfloor, 140lb/ft 0.113 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 0 Envelope loss/gain 9122 4756 349 172 12 a) Infiltration 2224 568 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 3975 0 Subtotal (lines 6 to 13) 1 11346 9299 349 172 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 -349 -172 14 Subtotal 11346 9299 0 0 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 Total room load 11346 9299 0 0 Air required (cfm) 3181 318 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri I1t501Tt' 2017-Mar-1015:49:36 9• Right -Suite@ Universal 2017 17.0.19 RSU17939 Page 1 .ACCA ...ad Finals\Knowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W ��� Right-J® Worksheet Job: Russell & Linda Knowles r q AHU-1 GrndFl Date: Mar 10, 2017 By: Tom Platania ProCalcs, LLC P.O. Box882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Art Studio Cabana Bath 2 Exposed wall 35.0 ft 10.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 334.0 ft 1.0 x 99.0 ft 5 Room area 334.0 ft' 99.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ft2) Load number (Btuh/ft;°F) (Btuh/ft5 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 0.095 n 2.97 1.25 100 160 476 200 0 0 0 0 4A5-2ob 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 n 14.08 18.71 30 0 423 411 0 0 0 0 4B5-2fb 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 11 4B5-2fb _ _ ._ 0.450 n 0.00 _ 0.00 ; _ 0 0 _ __0 _ 0 _ 0 0 _ _ _ 0 0 13A-7.5ocs 0.095 a 2.97 1.25 160 140 416 175 100 76 226 95 1OD-b 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 1OD-b 0.450 a 14.08 19.60 0 0 0 0 24 24 338 470 4A5-2ob 4A5-2ob 0.450 0.450 a a 14.08 0.00 23.71 0.00 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2obd 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 14.08 23.71 20 20 28.2 474 0 0 0 0 W 13A-7.5ocs 0.095 s 2.97 1.25 0 _ 0 0 0 0 0 _ _ 0 0 1OD-b 0.450 s 14.08 19.60 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 4B5-2fb 0.450 0.450 s s 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08 23.71 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s_ _ 0.00 0.00 _ _ 0 0 0._ 0 0 0 0 0 W Partition Wall 0.144 s 4.51 2.82 0 0 0 0 0 0 0 0 W 13A-7.5ocs 0.095 w 2.97 _ 1.25 0 0 0_ 0 0 0 0 0 13A-7.5ocs 0.095 w 0.00 6.00 0 0 0 0 0 0 0 0 1OD-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 1OD-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 1OD-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 - 2.97 0.75 0 0 0 0 0 0 _0 0 P Frm wall, r-11 cav i 0.144 4.52 1.70 0 0 0 0 0 0 0 0 R Partition Wall 0.144 - 4.51 1.70 130 130 587 221 0 0 0 0 L-D 11 DO 0.390 n 12.21 11.82 0 0 0 0 0 0 0 0 P Partition Wall 0.101 0.00 0.00 0 0 0 0 0 0 0 0 P Partition Wall 0.101 3.17 1.56 i 0 0 0 0 0 0 _ 0 0 C 16B-21md 0.044 0.00 0 0 0 0 0 0 0 0 C 17A-0zd' 0.287 - _O.00 0.00 0.00 6 0 0 -0 . 0 0, 0_ 0 F 19A-Obstp 0.368 - 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpm 1.186 36.93 0.00 334 35 1293 0 99 10 , 369 0 F 22A-tpm 1.180 - 0.00 0.00 0 0 0 0 0 0 0 0 F Flrfloor, 140 lb/ft _ 0.102 - 0.00 0.00 0_ 0 0 0 0 0 0 0 F Fir floor, 140 lb/ft 0.113 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 0 Envelope loss/gain 3476 1481 933 565 12 a) Infiltration 837 214 239 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1500 0 Subtotal (lines 6 to 13) 4313 3195 1173 626 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4313 3195 1173 626 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 4313 3195 1173 626 Air required (cfm) 121 109 33 21 Calculations aDDroved by ACCA to meet all requirements of Manual J 8th Ed. Wri 17tSOft' 2017-Mar-1015:49:36 Right -Suite@ Universal 2017 17.0.19 RSU17939 Page 2 ACCA ...ed Finals\Knowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W RIg ht-JO Worksheet Job: Russell & Linda Knowles I * we.�ne�!Qln Date: Mar 10,2017 AHU-1 GmdF1 By: Tom Platania ProCalcs, LLC P.O. Box 882032. Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Laundry Recreation 2 Exposed wall O ft O ft 3 Room height 10.0 ft heaticool 10.0 ft heat/cool 4 Room dimensions 11.5 x 13.0 ft 8.0 x 16.5 ft 5 Room area I 149.5 ft' 132.0 ft2 Ty Construction number U-value (Btuh/ft' °F) Or HTM (Btuh/ft5 Area (W) or perimeter (ft) Load (Btuh) Area (ft5 or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 0.095 n 2.97 1.25 0 0 0 4A5-2ob 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 n 14.08 13.71 0 0 0 0 0 0 0 0 4B5-2fb 0:450 n 0.00 0.00 0 0 0 0 0 0 0 0 11 4B572fb_ _ 0.450 _n _ _ 0.00 . _ _ 0.00 _ _ _0 _ -. 0 -_ 0 , _ 0 0 0 _ _ 0 . _ _ _ _ 0 13A-7.5ocs 0.095 a 2.97 1.25 0 0 0 0 0 0 0 0 1OD-b 0.450 a 0.00 0.00 ' 0 0 0 0 0 0 0 0 10D-b 0.450 a 14.08 19.60 0 0 0 0 0 0 0 0 4A5-2ob 4A5-2ob 0.450 0.450 a a 14.08 0.00 23.71 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2obd 0.450 a 0.00 0.00 i 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 1 0- 0 0 0 0 0 0 0 4B5-2fb 13A-7.5ocs 0.450 0.095 a s 1.4.08 2.97 _ 23.71 1.25 0_ 0 0 0 0 0 0 0 _ 0 0 0 0 0 0 0 0 1OD-b 0.450 s 14.08 19.60 0 0 0 0 0 0 0 0 4A5-2ob 4A5-2ob 0.450 0.450 s s 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 4A5-2ob 0.450 0.450 s s 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4B5-2fb 4B5-2fb 0,450 0.450 s s 0:00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08 23.71 0 0 0 0 0 0 0 .0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 W 4B5r2_fb_,. ,_._ _ _ Partition Wall 0.450 0.144 _ s s .M, 4.51 0.00 M2 ! t ' 0. 100 ,_0 100 _ 1 451 0 282 0 0 , 0, 0 „ _ -0 0 . 0 W 13A-7.5ocs 13A-7.5ocs 0.095 0.095 w_ w 2.97 0.00 1.25 0.00 0 0 _ 0 0 0 0 0 0 _ _ _ _ _ 130 0 130 0 _ 387 0 _ _ --0- 162 0 10D-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 1OD-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 1OD-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 485-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 ; 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 2.97 . _ 0.75 , 145 _ 145 431 109 0 _ 0 0 _ 0 Frm wall, r-11 cav i- 0.144 - 4.52 1.70 ; 0 0 0 _ 0 30 30 135 51 _P RFI Partition Wall 0.144 - 4.51 1.70 0 _ 0 0 0 0 0 0 0 11D0_ - 0.390 _n 12.21- 11.82 I _ 0 0 0 0 _ _ 0 0 0 0_ _L-D P Partition Wall_ 0.101 - 0.00 0.00 ; 0 0 0 0 0 0 0 0- _ P. - _ Partition Wall _ 0.101 - 3.17 1.56 0 _ 0 0 _ 0 0- 0 0 - 0. C 16B-21md 0.044 - 0.00 0.00 0 0 0 0 0 0 0 0 C , 17A-Ozd ' 0.287 - jo.00 .0.00 -0 0 0 6. 0 F_ F 19A-Obstp 22A-tpm 0.368 1.1bo - - 0.00 36.93 0.00 6.60 { 0 _. 150 0 0 0 0 0 0 0 132 0 0 _0 0 0 0 F 22A-tpm 1.180 - 0.00 0.00 0 0_ 0- 0 0 0 0 0 F _ _ Flrfloor, 140 Ib/ft 0.102 - 0.00 0.00 - _ 0 0 0 _ 0 0 0 0 0 F Fir floor, 140 lb/ft 0.113 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 0 Envelope loss/gain 882 390 522 213 12 a) Infiltration 239 61 311 79 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 1475 Subtotal (lines 6 to 13) 1122 952 833 1768 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 95 47 254 125 14 Subtotal 1217 998 1087 1892 15 Duct loads -090 0% 0 0 -0% 0% 0 0 Total room load 1217 998 1087 1892 Air required (cfm) 34 34 30 65 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ vwr9 Ilit50fFt" 2017-Mar-1015:49:36 9. Right -Suite® Universal 2017 17.0.19 RSU17939 Page 3 AC-'C!` ...ad Finals%Knowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W ■ Right-M Worksheet Job: •Russell & Linda Knowles 7?*11rd Date: Mar 10, 2017 AHU-1 GmdFl By: Tom Platania ProCalcs, LLC P.O. Box882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Storage Vest 2 3 Exposed wall Room height 25.0 ft 10.0 ft heat/cool 0 ft 10.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 150.5 ft ft 150.5 ft' 1.0 x 240.3 ft 240.3 ft2 Ty Construction U-value Or HTM Area (ftj Load Area (ft) Load number (Btuh/ft;°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.566s' 4A5-2ob 4B5-2fb 0.095 0.450 0.450 n n n 2.97 0.00 14.08 1.25 0.00 13.71 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 4B5-2fb 4B5-2fb 0.450 0.450 n _n 0.00 WOO 0.00 _ 0.00 0 I . 0 0 _ _ . _0 0 _ . _0 0 - . _ _ 0 0 0 0 _ . .0 0 _ -_. _ _ 0 0 . _ .0 _ 13A-7.5ocs 1OD-b 1OD-b 0.095 0.450 0.450 a a a 2.97 0.00 14.08 1.25 0.00 19.60 150 0 0 140 0 0 416 0 0 175 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2ob 4A5-2ob 0.450 0.450 a a 14.08 0.00 23.71 0.00 10 0 10 0 141 0 237 0 0 0 0 0 0 0 0 0 4A5-2obd 4B5-2fb 4B5-2fb 0.450 0.450 0.450 a a a 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4B5-2fb 13A-7.5ocs 0.450 0.095 a s 14.08 2.97 23.71 1.25 0 100 0 61 0 183 0 77 0 0 0_ 0 0 0 0 0 W 1OD-b 4A5-2ob 0.450 0.450 s s 14.08 0.00 19.60 0.00 24 0 24 0 338 0 470 0 0 0 0 0 0 0 0 0 4A5-2ob 4A5-2ob 0.450 0.450 s s 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2ob 4A5-2ob 0.450 0.450 s s 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08 23.71 1 15 15 205 346 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 _ s 0.00 0.00 .; 0 0 0 _ 0 0 0 0 0 W Partition Wall 0.144 s 4.51 2.62 , 0 0_ 0 0 0 0 0 0 W _ 13A-7.5ocs _ 0.095 w 2.97 _ 1.25 ;, 0 0 0 0 0 0 0 0 W 13A-7.5ocs 0.095 w 0.00 0.00 6 0 0 0 0 0 0 0 10D-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 10D-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 10D-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 +, 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0_ 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 2.97 0.75 _ 0 0 0_ 0 0_ 0 0 0 P Frm wall, r-11 cav i 0.144 4.52 0 0 0 0 0 0 0 0 Partition Wall 0.144 4.51 .1-.70 1.70 0 0 0 0 85 37 167 63 11 DO _ 0.390 n 12.21 11.82 . 01 0 0 0 48 48 586 567 P P_ Partition Wall _ Partition Wall 0.101 0.101 0.00 3.17 0.00 _ 1.56 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16B-21md 0.044 0.00 0.00 0 0 0 0 0 0 0 0 .C_ , 17A-Ozd_. 0..287 0.00 0.00 '. 6 0 0 0 . 0 0 0 6 F 19A-Obstp 0.368 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpm 1.180 36.93 0.00 1.51 25 923 6 240 0 0 0 F 22A-tpm 1.180 - 0.00 0.00 0 0 0 0 0 0 0 0 F. - Flrfloor, 140lb/ft 0.102 - 0.00 o.0o' 0 0 0 0 0 0 0 0. F Flr, floor, 140 lb/ft 0.1131 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 0 Envelope loss/gain 2207 1305 753 630 12 a) Infiltration 598 153 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13) 2804 1957 753 630 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2804 1957 753 630 15 Duct loads -0% 00/ 0 0 -0% 0% 01 0 Total room load 2804, 1957 753 630 Air required (cfm) 79 67 21 22 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wf i 11tSOft' 2017-Mar-10 15:49:36 ACCA Right -Suite@ Universal 2017 17.0.19 RSU17939 Page 4 ...ad Finals\Knowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W `*W. t.ssIrni i Right-M Workshedl Job: Russell & Linda Knowles Date: Mar 10, 2017 AHU-2 SecFlr By: Tom Platania ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name AHU-2 SecFlr 2nd Fir Stairs 2 Exposed wall 186.0 ft 9.5 ft 3 Room height 11.6 ft 17.7 ft heat/cool 4 Room dimensions ( 18.5 x 9.5 ft 5 Room area 2038.5 ftz 175.8 ft' Ty Construction U-value Or HTM Area (ftj Load Area (ft� Load number (Btuh/ft2-°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs -' 0.095 n 2.97 1 25 - 52"1 459 " --- _ - - - - - 1363 � $72 - 0 - - 0 b 0 4A5-2ob 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 11 4B5-2fb 13A-7f5ocs - 0.450 0.45- n -e 14.08 08 - 14. 13.71 ---1' 1.25 20 42 558 0 - --0 433 282 -592. 1289 274 576. 540 0 - 0 40 0 -- -0 �40 0 0 119 0 0 50 -- 10D-b 10D-b 0.450 0.450 a a 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2ob 0.450 a 0.00 0.00 0 0 0 0 0. 0 0 0 4A5-2ob 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2obd 0.450 a 14.08 42.53 104 34 1465 4424 0 0 0 0 4B5-2fb 0.450 a 14.08 23.71 10 20 141 237 0 0 0 0 4B5-2fb 0.450 a 14.08 23.71 10 20 143. 241 0 0 0 0 4B5-2fb a 0.001 0.00 0 0 0,._ 0 W -_ 13A-7.5ocs _.0.450 0.095 s 2.97 1.25 _ _ _ :0- 605 " 519 1545 -0 648 _ 199 _0 143 _0 427 _ 179_ 1013-b 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 4A5-2ob 0.450 0.450 s s 0.00 0.00 _ 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08 24.96 10 0 139 247 10 0 139 247 4B5-2fb 0.450 s 14.08 24.96 30 0 423 749 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 4B5-2fb - _ -...,. 0.450 0.450 s --s. 14.08 . _ 14.08 24.96 -24.96 16 30 0 _ 0 224 423 397 _ - 749. 16 _ 30 0 0 224 _- - .423 397 749 W_ W _ Partition Wall 1.3A-7.5ocs 0.144 0..095 _ s _ w 0.00 - _ _ 0.00 - _ 0.00 - 0.00 _ _ 0 0 -- _ 0 _ 0 0 0_ 0 0 - _ 0 0- _ 0 - 0 0 0_ 0_ - _ 13A-7.5ocs 0.095 w 2.97 1.25 464 292 867 364 0 0 0 0 10D-b 0.450 w 14.08 24.91 96 127 1352 2392 0 0 0 0 10D-b 0.450 w 14.08 29.35 48 37 676 1409 0 0 0 0 10D-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 14.08 23.71 8 17 118 199 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 14.08 24.23 10 20 141 242 0 0 0 0 4B5-2fb 0.450 w-- 10 19 141 250 0 0 0. _ -L-G P_ - 13A-7.5ocs 0:095 -_ _ .14.08 _ 0.00_ " _24,95 0.00. _ _ 0 . 0 _ 0 _- . 0 - _ _ 0 ,_ _ 0 _ - _ - 0_ _ -0- '__0 P Fnp wall, r-11 cav_ i 0.144 0.00 0.00 0 0 0 0 0 0 0 0. q t-D - Partition Wall 11 DO _- _ 0.144 _ _0.390 _ - n 0.00 _ 0.00- 0.000 -- -0.00 _ _ 0 _ 0 - ___0 0 . 0 0 0 0 _ _ _0 0 -0 0 _ 0 0 _- _. -0 P Partition Wall.. 0.101 - 3.17 1".20 125 125 396 _ 125 125 _ 396 149_ -P-- - _ Partition Wall _ 0.101 -- 0.00 .- _ _ 0.06 _ 0 . - _0 _ - --.- 0 _ __149 . 0, _ _ 0 0 0 ._ ,- 0 C 16B-21md 0.044 - 0.00 0.00, 0 0 0 0 0 0 0 0 C - . 11A-0zd - 0.287 - 8.98" 18.60, , _ - 206 260 2336 _ - 4835 . 0 _ - - . 0 - 0 0_ 0.18o 0 0 0 0 0 0 0 0 F 22A tpmtP - 0:00 ._ 0.00� 0 0 0- 0 0 0 0 _b F 22A-tpm_ 1.180 , - 36.93 - -- 0.00 _ . _112 13 488 - 0 _ _- . 112 13 _ 488 0 _ F Fir floor, 140 Ib/ft 0.102 - 3.16 0.00 ... 26.1 261 829 -. _0 0 0 0 - 0 F Fir floor, 140 lb/ft 0.113 - 1.77 0.00 224 224 396 0 0 0 0 0 6 c)AED excursion 0 -148 Envelope loss/gain 16263 19494 2216 1622 12 a) Infiltration 5136 1311 572 146 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 0 0 Appliances/other 3250 0 Subtotal Qines 6 to 13) 21399 24975 2788 1769 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 21399 24975 2788 1769 15 Duct loads 0% 0% 0 0 -0% 0% Ul 0 Total room load 21399 24975 2788 1769 Air required (cfm) 742 742 97 53 Calculations aooroved by ACCA to meet all reauirements of Manual J 8th Ed. Wri hts-o t- 2017-Mar-1015:49:36 �• Right -Suite® Universal 2017 17.0.19 RSU17939 Page 5 ACCP....ed Finals\Knowles Residence Revised Final 3.rup Cale = MJ8 Front Door faces: W ' Y r Right-M Worksheet Job: Russell & Linda Knowles r .tTTVrq�1CS Date: Mar 10, 2017 AWU-2 SecFli By: Tom Platania ProCalcs, LLC P.O. Box882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Bath 1 Bath 2 2 Exposed wall 9.5 ft 9.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 6.5 x 10.0 ft 6.0 x 12.5 ft 5 Room area 65.0 ft2 75.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (13tuh/ft2 °F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 4A5-2ob 4B5-2fb 0.095 0.450 0.450 n n n 2.97 0.00 0.00 1.251 0.001 0.00 0 0 0 0 0 0 0 0 0 0 0 0 30 0 0 30 0 0 89 0 0 37 0 0 4B5-2fb 0.450 n 14.08 13.71 0 0 0 0 0 0 0 0 11 4135-2fb_ _ 0.450_ n- 14.08 _ 13.7.1 _ -0. 0 0 0 0 -0 0 0 _ 13A-7.5ocs 0.095 a 2.97 1.251 0 0 0 0 0 0 0 0 1OD-b 10D-b 0.450 0.450 a a 0.00 0.00 0.00 0.00 0 ! 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2ob 4A5-2ob 4A5-2obd 4B5-2fb 0.450 0.450 0.450 0.450 a a a a 0.00 0.00 14.08 14.08 0.00I 0.00 42.531 23.71 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 14.08 23.71 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 W 13A-7.5ocs 0.095 s 2.97 1.25 30 30 89 37 _ 0 0 0 0 10D-b 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08 24.96 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08 24.96 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08 24.96 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08 24.96 0 0 0 0 0 0 0 0 W Partition Wall 0.144 s 0.00 0.00 0 0 0 0 0 0 0 0 W 13A-7.5ocs 0.095 w 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 w 2.97 1.25 65 55 164 69 60 50 149 62 1OD-b 0.450 w 14.08 24.91 0 0 0 0 0 0 0 0 10D-b 0.450 w 14.08 29.35 0 0 0 0 0 0 0 0 10D-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 14.08 23.71 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 14.08 24.23 0 0 0 0 10 10 141 242 4B5-2fb 0.450 w 14.08 24.95 10 9 250 0 0 0 0 P 13A-7.5ocs 0.095 - 0.00 0.00 0 0 _ _141 0 0 _ 0 0 0 0 P Fmt wall, r-11 cav i 0.144 - 0.00 0.00 0 0 0 0 0 0 _ _ 0 0 Partition Wall 0.144 - 0.00 0.00 _ 0 _ 0 _ 0 0 0 0 0 0 11 DO _ 0.390 n 0.00 0.00 0_ 0_ 0 0 0 0 0 0 P Partition Wall 0.101 - 3.17 1.20 0 0 0 0 0 0 0 0 P Partition Wall 0.101 _ 0.00 0.00 0 0 0 0 0 0 0 0 C 166-21 m_d 0.044 - 0.00 0.00 0 0 0 0 0 0 0 0 C 17A-Ozd - 0.287 - 8.96 18.60 0 0 0_ 0. 0 0 0_ 0 F 19A-Obstp 0.368 - 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpm 1.180 - 0.00 0.00 . 0 0 0 0 0 0 0 0 F 22A-tpm 1.180 - 36.93 0.00 0 0 0 0 0 0 0 0 F Flrfloor, 140 Ib/ft 0.102 - 3.18 0.00 0 0 0 0 0 0 0 0 F Fir floor, 140 lb/ft 0.113 - 1.77 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 163 164 Envelope loss/gain 394 518 379 506 12 a) Infiltration 227 58 215 55 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 621 576 1594 561 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 621 576 594 561 15 Duct loads -0% 0% 0 0 -0% 0%1 0 0 Total room load 621 576 594 561 Air required (cfm) 122 171 21 17 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri ittsoft' �. 2017-Mar-1015:49:36 Right -Suite® Universal 2017 17.0.19 RSU17939 Page 6 � ` ...ed FinalsWnowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W Y 1 �` Job: Russell &Linda Knowles Right-J® Worksheet Date: Mar 10, 2017 AHU-2 SecFlr By: Tom Piatania ProCallas, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Bedroom 1 Bedroom 2 2 Exposed wall 34.0 ft 25.5 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 227.5 ft 1.0 x 170.8 ft 5 Room area 227.5 ft2 170.8 ft2 Ty Construction number U-value (Btuh/ft2L°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs - - 0.095 n J2.97 1.25'i- -0 - y -0 0 - - 0 125 905 312 -_, - 31- 4A5-lob 0.450 n 0.00 0.00I 0 0 0 0 0 0 0 0 4B5-2fb 0.450 n 0.00 0.00 0 0 0 0 0' 0 0 0 4B5-2fb 0.450 n 14:08 13.71 ! 0 0 0 0 20 0 282 274 11 ... 13A-7f5ocs 10D-b 0.095 0.450 a a 12.97 0.00 11.25 0.00 i1._- - 0 0 0 0 0 0 .00 0 _ .... 0 0 0 0 0. 0 , -_ 0. 0 10D-b 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 4A5-2ob 0.450 0.450 a a 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2obd 0.450 a 14.08 42.53I 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 14.08 23.71 0 0 0 0 0 0 0 0 0.450 4.08 12.97 21.25 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 13A-7.5ocs 0:095 _ _ s 2.97 1.25 215 _ _ 185 _ _ 550 231 0 _ _ 0 _ 0 0 13A-b� 0.095 s 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 01 0 0 0 0 0 0 0 4A5-2ob 4A5-2ob 0.450 0.450 s s 0.00 0.00 0.00 0.00 0 j 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 4B5-2fb 0.450 0.450 s s 14.08 14.08 24.96 24.961 0 30 0 0 0 423 0 749 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08 24.96 0 0 0 0 0 0 0 0 _ 4B5-2fb _ 0.450 .,a- 14.08 24.96• 0 0 0 _ _ 0 ._ __ _0 _ _ - 0 _ .0 0 W W tion Wall Partition 13A-7.5ocs 14 0.4 0.095 s _-w 0.00 0.00 0.00 0.00; 0 'i _ 0 0 0 0 0_ 0 0. 0 0 0 _0. 0 0 0 0 13A-7.5ocs 10D-b 10D-b 0.095 0.450 0.450 w w w 2.97 14.08 14.08 1.25 24.91 29.35 125 48 0 77 32 0 229, 676 0 96 1196 0 130 48 0 82 32 0 244 676 0 102 1196 0 10D-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 4B5-2fb 0.450 0.450 w w 14.08 0.00 23.71 0.00 0 ; 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 14.08. 24.23 0 0 0 0 0 0 0 0 4B5-2fb 0.450 14.08 24.951. 0 0 0_ 0 0 0 0 0 P--- 13A-7.56cs 0.09-5 -w 0.00 _ 0.00 0 0 0 0 0 0 _ 0 0 13 Frm wall, r-11 cav i 0.144 0.00 0.00 0 0 0_ 0 0_ 0 0 0 RR Partition Wall 0.144 _- - 0.00 0.001 0 0 _- 6- 0 0 0 _ 0 0 _1-D P 11D0_ - Partition Wall 0.390 0.101 n 0.00, 3.17 0.00% 1.20 0 1 0 0 0 0. 0 0 0 „_ 0. 0 _ _ _ 0 0 0 0 _ 0 0 P _ Partition Vllall 0.101. - b.00 _.- 0.00 1 - 0 0 0 0 0 -0 _ _ 0. 0 C 16B-21 and 0.044 - 0.00 0.00 1 0 0 0 0 0 0 0 0 C . -17A-0zd 0.287 - 8.98. 18.00. . 0 0 -0, _0 . . . 0 0., 0 0. F 1'9A70bstp 0.368 0.00 0 0 0 0 0 0 0 0 F- 22A-tpm 1.180 _- 0.00' _0.00 0.00 , 0 0 0 0 0 0 0 0 F 1.180 - 36.93 0.00 1- 0_ 0 0 0 0 0 0 0- F _22A-tpm Fir floor, 140 lb/ft 0.102 _ - 3.18 _ _ 0.00 ". . , 0 0 0 0 _ - 6 0 _ 0 0 F Fir floor, 140 Ib/ft 0.113 - 1.77 0.00 224 224 396 0 0 0 0 0 6 c)AED excursion 158 373 Envelope loss/gain 2274 2429 1785 2077 12 a) Infiltration 813 208 610 156 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1 3087 2637 _ 2395 2232 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 6 0 14 Subtotal 3087 2637 2401 2232 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 3087 2637 2401 2232 Air required (cfm) 107 78 83 66 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ' V1/riihtsq t• 2017-Mar-1015:49:36 �- Right -Suite@ Universal 2017 17.0.19 RSU17939 Page 7 .4CCA ...ad Finals\Knowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W ��� Right-JO Worksheet Job: Russell & Linda Knowles Ic AHU-2 SecFlr Date: Mar 10, 2017 By: Tom Platania ProCalcs, LLC P.O. Box882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Gallery Grt Rm Ktchn Dnng 2 Exposed wall 7.0 ft 86.0 ft 3 Room height 12.0 ft heat/cool 11.5 ft heat/cool 4 Room dimensions 1.0 x 244.0 ft 1.0 x 948.3 ft 5 Room area 244.0 ft2 948.3 ft2 Ty Construction number U-value (Btuh/ft2--°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.56cs 0.095 6 2.97 1.25 0 0 0 0 311 269 798 336 4A5-2ob 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 n 14.08 13.71 0 0 0 0 0 0 0 0 11 4B5-2fb _ _ _ 0.450 n 14.08 . _ 13.71 0 0 0 0 _ _ 42 0 592 576 _ 13A-7.5ocs 0.095 a 2.97 1.25 0 0 0 0 518 393 1170 491 10D-b 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 1OD-b 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2obd 0.450 a 14.08 42.53 0 0 0 0 104 17 1465 4424 4B5-2fb 0.450 a 14.08 23.71 0 0 0 0 10 10 141 237 4B5-2fb 0.450 a 14.08 23.71 0 0 0 0 10 10 143 241 4135-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 W 13A-7.5ocs 0.095 s 2.97 1.25 0 0 0 0 161 161 479 201 1OD-b 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08 24.96 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08 24.96 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08 24.96 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08 24.96 0 0 0 0 0 0 0 0 W Partition Wall 0.144 s 0.00 0.00 0 0 0 0 0 0 0 0 W 13A-7.5ocs 0.095 w 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 w 2.97 1.25 84 28 82 34 0 0 0 0 1OD-b 0.450 w 14.08 24.91 0 0 0 0 0 0 0 0 1OD-b 0.450 w 14.08 29.35 48 18 676 1409 0 0 0 0 1OD-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 14.08 23.71 8 8 118 199 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 14.08 24.23 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 14.08 24.95 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 0.00 0.0o 0 0 0 0 0 0 0 0 P Frm wall, r-11 cav i 0.144 - 0.00 0.00 0 0 0 0 0 0 0 0 Fj Partition Wall 0.144 - 0.00 0.00 0 0 0 0 0 0 0 0 L-D 11 DO 0.390 n 0.00 0.00 _ 0 0 0 0 0 0 0 0 P Partition Wall 0.101 - 3.17 1.20 0 0 0 0 0 0 0 0 P Partition Wall 0.101 - 0.00 0.00 0 0 0 0 0 0 0 0 C 16B-21md 0.044 - 0.00 0.00 0 0 0 0 0 0 0 0 C 17A-0zd 0.287 - 8.98 18.60 . 0 0 0 0 _ 260 260 2336 4835 F 19A-0bstp 0.368 - 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpm 1.180 - 0.00 0.00 0 0 0 0_ 0 0 0 0 F 22A-tpm 1.180 - 36.93 0.00 0 0 0 0 0 0 0 0 F Fir floor, 140 lb/ft 0.102 - 3.18 0.00 0 0 0 0 261 261 829 0 F Fir floor, 140 lb/ft 0.113 - 1.77 0.00 0 01 0 0 0 0 0 0 6 c)AED excursion 544 -1219 Envelope loss/gain 876 2187 8014 10120 12 a) Infiltration 201 51 2365 604 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 4 920 Appliances/other 0 2900 Subtotal (lines 6 to 13) 1077 2238 10380 14544 Less external load 0. 0 0 0 Less transfer 0 0 0 0 Redistribution 11 0 13 0 14 Subtotal 1089 2238 10393 14544 15 Duct loads -0% 0% I 0 0 U./oll 0% 0 0 Total room load 1089 2238 10393 14544 Air required (cfm) 36 66 360 432 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrri htrsOt`t' 2017-Mar-1015:49:36 ACCA Right -Suite® Universal 2017 17.0.19 RSU17939 Page 8 ...ad Finals\Knowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W ■■ Right-JO Worksheet Job: Russell & Linda Knowles 4vica■� Date: Mar 10, 2017 q w°��°- AHU-2 SecFlr By: Tom Platania ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: Prodalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Pantry WIC 1 2 Exposed wall 0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 11.5 x 4.0 ft 6.0 x 7.5 ft 5 Room area 46.0 ft2 45.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (W) Load number (Btuh/ft'L-*F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 - 13A-7.56cs - - - - 0.095 -n- 2.97 1.25 - - 0 - 0 --o - 0 -0 - - 0 - -0 0 4A5-2ob 0.450 n 0.00 0.0o _ 0 0 0 0 0 0 0 0 4B5-2fb 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 n 14.08 13.71 0 0 0 0, 0 0 0 0 11 485-2fb - - - 0.450 _ .n 14.08 13.71. - -0 - .0 0 - 0 - 0 0 ._ -� - -0 13A-7.5ocs 0.095 a 2.97 1.25 0 0 0 0 0 0 0 0 1OD-b 0.450 a 0.00 0.00 1 0 0 0 0 0 0 0 0 1OD-b 4A5-2ob 0.450 0.450 a a 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2ob 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2obd 0.450 a 14.08 42.53 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 14.08 23.71 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 14.08 23.71 0 0 0 0 0 0 0 0 4B5-2fb 0.450 0.00 1 0 '0 0 0 0 0 0 0 0 1N 13A-7.5ocs 0.095 __a s 2.97 --0.00 1.25 _1. -0 - 0 0 - -0 0 -0 0 1OD-b 0.450 s 0.00 0.00 i 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 1 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08 24.96 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08 24.96 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08 24.96 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 14.08. _ 24.96 -,0- - 0 _ - _ .O 0 _ -0 0 0 W - W - _ Partition Wall- _ 13A-7.5ocs _ _ _- 0.144 _ 0.095 s w - 0.00 _ 0.00 0.00- 0.00 0 _; 0 _ 0 - 0- 0 - _ _ 0 0 _ 0,_ - 0 0 0 0 _0 0 - - 0 _ 0_ 0 13A-7.5ocs 1OD-b 0.095 0.450 w w 2.97 14.08 1.25 24.91 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1013-b 0.450 w 14.08 29.35 0 0 0 0 0 0 0 0 1OD-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 14.08 23.71 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 14.08 24.23 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 14.08 24.95 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095. _ - 0.00 0.00 0 _ 0 _ _ _ - 0 _ _. _ 0 , _ _ 0 _ 0 _ _ _- 0 0 P Fmi wall, r-11 cav i, 0.144 0.00 0.00 0 0 0 0 0 0_ 0 0 R �- Partition Wall 0A44 _- - 0.00 0.00 0 0 0 0 0 0 0 0 _11 DO __- _ _ _- - _ 0.390 -n_.... _ 0.00 _ _ 0.00 0 -0 - _ 0. -_ 0 _ - 0 0 0 _ 0 _ P Partition Wall 0.101 3.17 1.20 0 0 0 0 0 0 P- _ _ Partition Wall _ '' OA01 _ _ 0.00_ 0.00 0 -0 _ _ _ 0 _ _ 0 6 _ 0 0 _ _ 0. -0 0 C 16B-21 md 0.044 0.00 0.00 0 0 0 0 0 0 _ 0 _ _ 0 C 17A70zd_- - _ . .. 0.287 r_ 8.98 - 18.bo , .- 0 . 0 0 0 0 0 0 .- 0 F 19A-Obstp 0.368 - 0.00 OAO 0 0 0 0 0 0 0 0 F 22A-tpm _ -. 1.180 _- 0.00 _ 0.00 0 0 0 - -- 0 0 0-,.- 0 0 F 22A-tpm _ 1,180 36.93 0.00 0 0 0 0 0 0 0 0 F - Fir floor, 140 Ib/ft. 0.102 _ _ - 3.18 _ _ 0.00 _ 0 0 0. _ 0 _ 0 _ _ 0 _ 0 0 F Fir floor, 140 Ib/ft 0.113 - 1.77 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 -27 Envelope loss/gain 35 0 61 -27 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 350 Subtotal (lines 6 to 13) 35 0 61 323 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -35 0 0 0 14 Subtotal 0 0 61 323 15 Duct loads -0% 0% 0 0 -0% 0%1 0 0 Total room load 0 0 61 323 Air required (cfm) 0 0 2 10 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wtti F1t90ft" 9. 2017-Mar-1015:49:36 Right -Suite@ Universal 2017 17.0.19 RSU17939 Page 9 ACC" ...ad Finals\Knowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W Right-JO Worksheet Job: Russell & Linda Knowles `� AHU-2 SecFlr Date: Mar 10, 2017 By: Tom Platania ProCalcs, LLC P.O. Box882032, Part Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name WIC 2 2 Exposed wall 5.5 ft 3 Room height 10.0 ft heat/cool 4 Room dimensions 7.5 x 5.5 It 5 Room area 41.3 ftz Ty Construction U-value Or HTM Area (ftj Load Area Load number (Btuh/ftL-°F) (Btuh/ft5 or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.56cs 0.095 n 2.97 1.25.- 55 55 164 69 4A5-lob 0.450 n 0.00 0.00 0 0 0 0 4B5-2fb 0.450 n 0.00 0.00 0 0 0 0 4B5-2fb 0.450 n 14.08 13.71 0 0 0 0 11 4B5-2fb _ _ 0.450 _ n 14.08 _ 13.7,1 _ _0 -0 _ _ 0.. 0 _ 13A-7.5ocs 0.095 a 2.97 1.25 0 0 0 0 1OD-b 0.450 a 0.00 0.00 0 0 0 0 1OD-b 0.450 a 0.00 0.00 0 0 0 0 4A5-2ob 0.450 a 0.00 0.00 0 0 0 0 4A5-2ob 0.450 a 0.00 0.00 0 0 0 0 4A5-2obd 0.450 a 14.08 42.53 0 0 0 0 4B5-2fb 0.450 a 14.08 23.71 0 0 0 0 4B5-2fb 0.450 a 14.08 23.71 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 W 13A-7.5ocs 0.095 s 2.97 1.25 0 0 0 6 1OD-b 0.450 s 0.00 0.00 0 0 0 0 4A5-2ob 0.450 a 0.00 0.00 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 4A5-2ob 0.450 s 0.00 0.60 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 4A5-2ob 0.450 s 0.00 0.00 0 0 0 0 4B5-2fb 0.450 s 14.08 24:96 0 0 0 0 4B5-2fb 0.450 s 14.08 24.96 0 0 0 0 4B5-2fb 4B5-2fb 0.450 0.450 s s 0.00 14.08 0:00 24:96 0 0 0 0 0 0 0 0 W 4B5-2fb. Partition Wall 0.450 0.144 .- s s 14.08 0.00 .24.96 0'00 _0 0 0 0 0 0- 0 W _ 13A-7.5ocs _ 0.005 W 6.00 0.00 0-- _ _0 _0 0 0 13A-7.5ocs 0.095 w 2.97 11.25 0 0 0 0 1OD-b 0.450 w 14.08 24.91 0 0 0 0 1OD-b 0.450 w 14.08 29.35 0 0 0 0 1OD-b 0.450 w 0.00 0.00 0 0 0 0 4A5-2ob 0.450 w 0.00 0.00 0 0 0 0 4B5-2fb 0.450 w 14.08 23.71 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 4B5-2fb 0.450 w 14.08 24.23 0 0 0 0 4B5-2fb 0.450 w 14.08 24.95 0 0 0 P 13A-7.5ocs - 0.695 _ - 0.00 0.00 _0 0 0 0 - 0 P Frm wall, r-11 cav i 0.144 - 0.00 0.00 0 0 0 0 R - Partition Wall 0.144 - 0.00 0.00 0 0 _ 0 0 _ 11 DO _ . _ _ ._ . . _ 0.390 _ n 0.00 - _ 0.00 0 _ 0 0 0 _ _D P Partition Wall 0.101 3.17 1.20 0 0 0 0 P _ Partition Wall 0.101 _ 0.00 : 0.00 0 0 0 _ 0 C 1613-21 m_d 0.044 0.00 0.00 0 0 0 0 C 17A-Ozd 0.287 8.98. 18.60 , 0 0 0_ 0 F 19A-Obstp_ 0.368 0.00 0.00 0 0 0 F 22A-fpm . 1.180 - 0.06 0.00 0 _0 0 0 0 F 22A-tpm 1.180 36.93 '0.00 0_ 0_ 0 0 F. FI[floor, 140lb/ft 0.102 - 3.18 0.00 0 0 _ 0 0 F Firfloor, 140 lb/ft 0.113 1.77 0.00 0 01 0 0 6 c)AED excursion -8 Envelope loss/gain 229 61 12 a) Infiltration 132 34 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 361 94 Less external load 0 0 Less transfer 0 0 Redistribution 5 0 14 Subtotal 365 94 15 Duct loads -0% 0% 0 0 Total room load 365 94 Air required (cfm) 13 3 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri fltt sOtit' 2017-Mar-10 15:49:36 Right -Suite® Universal 2017 17.0.19 RSU17939 Page 10 ACC` ...ad Finals\Knowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W Right-JO Worksheet 'A. ;"CaC Job: Russell & Linda Knowles r �� AHU-3 Master 3rd Date: Mar 1Q, 017 By: Tom Platanitania ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name AHU-3 Master 3rd 3rd Fir Stairs 2 Exposed wall 186.0 ft 8.0 ft 3 Room height 10.5 ft 12.0 ft heat/cool 4 Room dimensions 19.0 x 8.0 ft 5 Room area 1780.0 ft' 152.0 ft' Ty Construction number U-value (Btuh/ft? "F) Or HTM (Btuh/ft� Area (ftl or perimeter (ft) Load (Btuh) Area (ftj or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.50cs' 0.695 6 2.97 1.26 494 484 1439 604 0 0 0 0 4A5-2ob 0.450 n 14.08 13.71 10 0 141 137 0 0 0 0 4B5-2fb 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 11 4B5-2fb _ 0.450 .n 0.00 0.00, -0 _ _ 0 _ _ _ 0. _ 0 _ 0 0 0 0 _. 13A-7.5ocs 0.095 a 2.97 1.25 480 308 916 384 0 0 0 0 1OD-b 0.450 a 14.08 20.94 48 88 676 1005 0 0 0 0 1OD-b 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 a 14.08 23.71 20 40 282 474 0 0 0 0 4A5-2obd 0.450 a 14.08 42.53 104 34 1465 4424 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 W 13A-7.5ocs 0.095 s 2.97 1.25 525 424 1262 529 96 40 120 50 10D-b 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.71 10 20 139 156 10 10 139 156 4A5-2ob 0.450 s 14.08 16.96 30 0 423 509 0 0 0 0 4A5-2ob 0.450 s 14.08 15.71 15 30 211 236 0 0 0 0 4A5-2ob 0.450 s 14.08 15.71 16 32 224 250 16 16 224 250 4A5-2ob 0.450 s 14.08 15.93 30 50 423 478 30 25 423 478 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00. 0.00 0 0. 0 0 0 0 0 0 W Partition Wall 0.144 s_ 0.00 0.00 0 0 0 0 0 0 0 0 W 13A-7.5ocs 0.095 w 0.00 0.00 0 0 0 0. 0 0 0 0 13A-7.5ocs 0.095 w 2.97 1.25 473 327 973 408 0 0 0 0 10D-b 0.4,50 w 0.00 0.00 0 0 0 0 0 0 0 0 1OD-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 1OD-b 0.450 w 14.08 28.53 48 42 676 1370 0 0 0 0 4A5-2ob 0.450 w 14.08 38.25 89 0 1251 3397 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 14.08 23.71 8 17 118 199 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 0.60 0.00 0 0 0 0 0 0 0 0 P Fnn wall, r-11 cav 1 0.144 - 0.00 0.00 0 0 0 0 0 0 0 0 L-D Partition Wall 0.144 0.00 0.00 0 0 0 0 0 0 0 0 11 DO 0.390 n 0.00 0.00, 0 0 0 0 0_ 0 0 0 P Partition Wall 0.101 - 0.00.- 0.00 0 0 0 0_ 0 0 0 0 P Partition Wall 0.101 - 0.00 0.00 0 0 0 0 0 0 0 0 C 16B-21md 0.044 - 1.38 2.37 1780 1780 24.51 42.14 152 152 209 360 C 17A-6id .._ 0.287 - 0.00 0.00 , 0 0 0 0 0 0 0 0 F 19A-Obstp 0:368 - 3.75 1.98 2 2 6 3 0 0 0 0 F 22A-tpm 1.180 - 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpm 1.180 - 0.0Q 0.00 0 0 0 0 0 0 0 0 F Fir floor, 140 lb/ft 0.102 -_ 0.00 0.00 0 0 0 0 0_ 0 0 0 F Fir floor, 140 Ib/ft 0.113 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 -116 Envelope loss/gain 13076 18776 1115 1177 12 a) Infiltration 4716 1204 230 59 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2470 10 Subtotal (lines 6 to 13) 17792 22449 1344 1235 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17792 22449 1344 1235 15 Duct loads 26% 1 299/6 4700 6555 26% 34% 355 421 Total room load 22491 29005 1700 1656 Air required (cfm) 263 1160 20 66 Calculations aDDroved by ACCA to meet all reauirements of Manual J 8th Ed. WPt Fltt:sOTt' 2017-Mar-1015:49:36 Right -Suite@ Universal 2017 17.0.19 RSU17939 Page 11 ACCA ...ad Finals\Knovdes Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W ��� Right-JO Worksheet Job: Russell & Linda Knowles �*' AHU-3 Master 3rd ! Date: Mar 10, 2017 By: Tom Platania ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Her Closet Her Master Bath 2 Exposed wall 27.0 ft 36.0 ft 3 Room height 9.7 ft heat/cool 9.7 ft heat/cool 4 Room dimensions 1.0 x 182.3 ft 1.0 x 245.0 ft 5 Room area 182.3 ft' 245.0 ft' Ty Construction number U-value (Btuh/ft? °F) Or HTM (Btuh/ft� Area (ft� or perimeter (ft) Load (Btuh) Area (ftj or perimeter (ft) Load (Btuh) Heat FC001 Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs- 0.095 n 2.97 1.25 141 141 418 175 190 189 562 236 4A5-2ob 0.45b n 14.08 13.71 0 0 0 0 10 0 141 137 4135-2fb 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 11 4B572fb 0.450 _n_ 0.00_ 0.00 0 0 0 0 0 _ _ 0 0. _ 0 13A-7.5ocs 0.095 a 2'.97 1.25 0 0 0 0 150 130 388 163 1OD-b 0.450 a 14.08 20.94 0 0 0 0 0 0 0 0 1OD-b 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 a 14.08 23.71 0 0 0 0 20 20 282 474 4A5-2obd 0.450 a 14.08 42.53 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0, 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0_ 0 0 W 13A-7.5ocs 0.095 s 2.97 1.25 0 0 0 0 0 0 0 0 1OD-b 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.71 0 0 0 0. 0 0 0 0 4A5-2ob 0.450 s 14.08 16.96 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.71 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.71 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.93 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s_ _ .0.00 _ 0.00 0 0 0_ 0 0 0_ 0 0 W Partition_Wall 0.144 s 0.00 0.00 , 0 0 0 0 0 0 0 0 W 13A-7.5ocs 0.095 w 0.00 0.00 0_ _ 0_ 0 0 0 0_ 0 0 13A-7.5ocs 0.095 w 2.97 1.25 121 77 229 96 0 0 0 0 1OD-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 1OD-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 1OD-b 0.450 w 14.08 28.53 0 0 0 0 0 0 0 0 4A5-2ob 0.450 w 14.08 38.25 44 0 625 1698 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 14.08 23.71 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 P_ 13A-7.5o6s 0.095 - O.Ob 0.00 0 0 0 _0 0 0 0 0 0 P Fnn_wall, r-11 cav i 0.144 - 0.00 0.00 0 0 0 0 0 0 0_ 0 q Partition Wall 0.144 - -0.00 0.00 0 0 0 0 0 _ 0 0 0 I-D 11 DO 0.390 n 0.00 0.00 0_ 0 0 0 0 0 _ 0 0 P Partition Wall 0.101 0.00 0 0 0 0 0 0 0 P Partition Wall 0.101 _ _0.00 0.00 0.00 0 0 0_ 0 0 0 -0 0 0 C 16B-21md 0.044 1.38 2.37 182 182 251 4.31 245 245 33.7 580 C 17A-Ozd.. 0.287 _ - 0.00 0.00 . 0 0_ 0 0 0 0 0 0 F 19A-Obstp 0.368 - 3.75 1.98 0 0 0 0 0 0 0 0 F 22A-tpm 1.180 - 0.00 0.b0 0 0 0 0 0 0 0 0 F 22A-tpm 1.180 - 0.00 AN 0 0 0 0 0 0 0 0 F Flrfloor,_1401b/ft 0.102 - .0.00 0.00 0 0 0 0 0 0 0 0 F Fir floor, 140 lb/ft 0.113 - 0.00 0.00 0 0 0 01 0 0 0 0 6 c)AED excursion 437 -198 Envelope loss/gain 1523 2838 1709 1391 12 a) Infiltration 626 160 835 213 b) Room ventilation 10 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13) 2149 2998 2544 2105 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2149 2998 2544 2105 15 Duct loads 26% 290 568 867 26% ol 672 609 Total room load 2717 3865 3216 2713 Air required (cfm) 32 155 38 109 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. wri htsoft• Page 12 2017-Mar-1015:49:36 Right -Suite® Universal 2017 17.0.19 RSU17939 ��` ...ad Finals\Knowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W �`� Right-JO Worksheet Job: Russell & Linda Knowles `�� AHU-3 Master 3rd ' Date: Mar 10, 017 By: Tom Platanitania ProCalcs, LLC P.O. Box882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Her WC His Closet 2 Exposed wall 0 ft 7.5 ft 3 Room height 10.0 ft heat/cool 9.7 ft heat/cool 4 Room dimensions 6.0 x 4.0 ft 13.0 x 7.5 ft 5 Room area 24.0 ft' 97.5 ft' Ty Construction U-value Or HTM Area (ft2 Load Area (ftj Load number (Btuh/ft;°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 0.095 n 2.97 1.25 0 0 0 0 0 0 0 0 4A5-2ob 0.450 n 14.08 13.71 0 0 0 0 0 0 0 0 4B5-2fb 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 11 4B5-2fb _ _ _ 0.450 n- 0.00 _ _ 0.00 0 0 0 0 _ 0 0 0. 0 13A-7.5ocs 0.095 a 2.97 1.25 0 0 0 0 0 0 0 0 1OD-b 0.450 a 14.08 20.94 0 0 0 0 0 0 0 0 1OD-b 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 cl 4A5-2ob 0.450 a 14.08 23.71 0 0 0 0 0 0 0 0 4A5-2obd 0.450 a 14.08 42.53 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 W 13A-7.5ocs 0.095 s 2.97 1.25 0 0 0 0 73 73 216 91 10D-b 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.71 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 16.96 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.71 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.71 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.93 0 0 0 0 0 0 0 0 4135-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4135-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4135-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4135-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 W Partition Wall 0.144 s 0.00 0.00 0 0 0 0 0 0 0 0 W 13A-7.5ocs 0.095 w 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 w 2.97 1.25 0 0 0 0 0 0 0 0 10D-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 10D-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 10D-b 0.450 w 14.08 28.53 0 0 0 0 0 0 0 0 4A5-2ob 0.450 w 14.08 38.25 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00- 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 14.08 23.71 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 - 0.00 0.00 0 0 0 0 0 0 0 0 P Frm wall, r-11 cav i 0.144 - 0.00 0.00 0 0 0 0 0 0 0 0 Partition Wall 0.144 - 0.00 0.00 0 0 0 0 0 0 0 0 11 DO 0.390 n 0.00 O.O,Q 0 0 0 0 0 0 0 0 P Partition Wall 0.101 - 0.00 0.00 0 0 0 0 0 0 0_ 0 P Partition Wall 0.101 - 0.00 0.00 0 0 0 0 0 0 0 0 C 1613-21md 0.044 1.38 2.37 24 24 33 57 98 98 134 231 C 17A-Ozd 0.287 - 0.00 0.00 0 0 0 0 0 0 0 0 F 19A-Obstp 0.368 - 3.75 1.98 0 0 0 0 0 0 0 0 F 22A-tpm 1.180 - 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpm 1.180 - 0.00 0.00 0 0 0 0 0 0 0 0 F Firfloor, 140 lb/ft 0.102 - 0.00 0.00 0 0 0 0 0 0 0 0 F Firfloor, 140 lb/ft 0.113 - 0.00 0.00 0 01 0 01 0 0 0 0 6 c)AED excursion -15 -31 Envelope loss/gain 33 42 351 290 12 a) Infiltration 0 0 174 44 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 120 0 Subtotal (lines 6 to 13) 33 162 525 334 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 33 162 525 334 1.5 Duct loads 1 26% 29% 9 47 26% 29% 139 97 Total room load 42 208 663 431 Air required (cfm) 0 B 8 17 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wright -soft- 2017-Mar-1015:49:36 Right -Suite@ Universal 2017 17.0.19 RSU17939 Page 13 '�Cp` ...ad Finals\Knowles Residence Revised Final 3.rup Calc = MJS Front Door faces: W ` ■ Right-J® Worksheet Job: Russell & Linda Knowles CAiCS ' Date: Mar 10, 2017 t w°-°�°��°a°� AHU-3 Master 3rd By: Tom Platania ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name His Master Bath His WC 2 Exposed wall 26.5 ft 0 ft 3 Room height 9.7 ft heat/cool 9.7 ft heat/cool 4 Room dimensions 1.0 x 181.8 ft 6.0 x 4.0 ft 5 Room area 181.8 ft' 24.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft2) Load number (Btuh/W-*F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 0.095 n 2.97 1.251 0 0 '0 0 0 0 0 0 4A5-2ob 0.450 n 14.08 13.71 0 0 0 0 0 0 0 0 4B5-2fb 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 11 4B5-2fb _ 0.450 _n _ 0.00 .__0.00 _,. _0 _ 0 0 __ 0 _ _ 0 _ _0 _ _ 0 :. 0 _ 13A-7.5ocs 0.095 a 2.97 1.25 0 0 0 0 0 0 0 0 10D-b 0.450 a 14.08 20.94 0 0 0 0 0 0 0 0 1OD-b 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 a 14.08 23.71 0 0 0 0 0 0 0 0 4A5-2obd 0.450 a 14.08 42.53 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0_ 0 0 0 0 0 0 0 W 13A-7.5ocs 0.095 s 2.97 1.25 136 121 359 151 0 0 0 0 1OD-b 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.71 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 16.96 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.71 15 15 211 236 0 0 0 0 4A5-2ob 0.450 s 14.08 15.71 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.93 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 . s 0.00 0.00 0 , 0 0 0 _ 0 0. _ 0 _ 0 W Partition Wall 0.144 s 0.00 0.00 0 0 0 0 6_ 0 0 0 W _ 13A-7.5ocs 0.095 w 0.00 0.00 0_ 0 0 0 0 0 0 0 13A-7.5ocs 0.095 w 2.97 1.25 121 77 229 96 0 0 0 0 10D-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 10D-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 1OD-b 0.450 w 14.08 28.53 0 0 0 0 0 0 0 0 4A5-2ob 0.450 w 14.08 38.25 44 0 625 1698 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 14.08 23.71 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0_ 0 0 0 0 P 13A-7.5ocs _ 0.095 - 0.00 0.00 0 0 0_ 0 0 0 0 0 P Fmi wall, r-11 cav i 0.144 - 0.00 0.00_ 0 0 0 0 0 0 0 0 R Partition Wall 0.144 - 0.00 _ 0.00 0 0 0 0 0 0 0 0 L-D 11DO 0.390 _n 0.00 _ 0.00 __0 0 0 0 0 _ 0 _ 0 0 P Partition Wall 0.101 - 0.00 0.00 0 0 0 0 0 0 0 0 _ P Partition Wall_ 0.101 - 0.00 _ -6. ao' _ 0 _ 0 _ 0 0 0 0 0 0 C 1613-21 md_ 0.044 - 1.38 2.37 182 182 250 430 24 24 3.3 57 C 17A-Ozd b.287 - 0.00 _ 0.60 0 0 0: 0. 0 0. 0 0. F 19A-Obstp 0.368 - 1.98 0 0 0 0 0 0 0 0 F 22A-tpm _ 1.1,80 - _3.75 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpm 1.180 - 0.00 0.00 0 0_ 0 0_ 0 0 0 F_ Flrfloor, 140 Ib/ft 0.102 0.00 0.00 0 `0 0 _0 0 0 0 0 _ 0 F Flrfloor, 140lb/ft 0.113 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 353 -18 Envelope loss/gain 1675 2964 33 39 12 a) Infiltration 615 157 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 150 Subtotal (lines 6 to 13) 2289 3121 33 189 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2289 3121 33 189 15 Duct loads 26% 29% 605 902 26% 29% 9 55 Total room load 2894 4023 42 244 Air required (cfm) 34 161 0 10 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WrsOfft' AC�A �ilht� Right -Suite® Universal 2017 17.0.19 RSU17939 2017-Mar-1015:49:36 Page 14 ..ad Finals\Knowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W V ,A, Ac 4. CS w..e W'v Vpk w Right-JO Worksheet AHU-3 Master 3rd ProCalcs, LLC Job: Russell & Linda Knowles Date: Mar 10, 2017 By: Tom Platania P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Master Bedroom Master Laundry 2 Exposed wall 44.5 ft 0 ft 3 Room height 12.0 ft heaticool 9.7 ft heat/cool 4 Room dimensions 19.0 x 15.5 ft 1.0 x 94.3 ft 5 Room area 294.5 ft' 94.3 ftz Ty Construction number U-value (Btuh/ft;-*F) Or HTM (Btuh/ft� Area (ft� or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.56cs 0.095 n 2.97 1.25 '120 120 357 150 0 0 0 0 4A5-2ob 4B5-2fb 0.450 0.450 n n 14.08 0.00 13.71 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 4B5-2fb 4B5-2fb 0.450 0.450 n n 0.00 0.00 0.00 0.00 0 0 0 0._ 0 0 0 0_ 0 0 0 0 0 0 0 0 13A-7.5ocs 1OD-b 1OD-b 0.095 0.450 0.450 a a a 2.97 14.08 0.00 1.25 20.94 0.00 228 0 0 124 0 0 369 0 0 155 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2ob 4A5-2ob 0.450 0.450 a a 0.00 14.08 0.00 23.71 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2obd 0.450 a 14.08 42.53 104 17 1465 4424 0 0 0 0 4135-21b 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 W 13A-7.5ocs 0.095 s 2.97 1.25 186 156 464 195 0 0 0 0 1OD-b 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.71 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 16.96 30 0 423 509 0 0 0 0 4A5-2ob 0.450 s 14.08 15.71 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.71 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.93 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0_ 0 0 0 0 0 W W Partition Wall 13A-7.5ocs 0.144 0.095 s w 0.00 0.00 0.00 0.00 0 0 0 _ 0_ 0 0 0 0 0 0 0 0 0 0 0 0 13A-7.5ocs 1OD-b 0.095 0.450 w w 2.97 0.00 1.25 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1OD-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 1OD-b 0.450 w 14.08 28.53 0 0 0 0 0 0 0 0 4A5-2ob 0.450 w 14.08 38.25 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 14.08 23.71 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 - 0.00 0.00 0 0 0 0 0 0 0 0 P Fnn wall, r-11 cav i 0.144 - 0.00 0.00 0 0 0 0 0 0 0 0 R Partition Wall 0.144 - 0.00 0.00 0 0 0 0 0 0 0 0 L-D 11 DO 0.390 n 0.00 0.00 0 _. 0.. 0 0 0 0 0 0 P Partition Wall 0.101 0.00 0.00 0_ 0 0 0 0 0 0 0 P Partition Wall 0.101 - 0.00 0.00 0 0 0 0 0 0 0 0 C 16B-21md 0.044 - 1.38 2.37 295 295 406 697 94 94 130 223 C 17A-Ozd 0.287 - 0.00 0.00 0 0 0 0 0 0 0 0_ F 19A-Obstp 0.368 - 3.75 1.98 0 0 0 0 0 0 0 0 F 22A-tpm 1.180 - 0.00 0.00 0 O_ 0 0 0 0. 0 0 F 22A-tpm 1.180 - 0.00 0.00 0 0 0 0 0 0 0 0 F Flrfloor, 140 lb/ft 0.102 - 0.00 0.00 0 0 0' 0 0 0 0 0 F Fir Floor, 140 lb/ft 0.113 - 0.00 0.00 0 0 0 0 0 0 Ol 0 6 c)AED excursion -555 -97 Envelope loss/gain 3482 5573 130 126 12 a) Infiltration 1277 326 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 900 Subtotal (lines 6 to 13) 4760 5899 130 1026 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4760 5899 130 1026 15 Duct loads 26% 29% 1257 1706 26% 29% 34 297 Total room load 6017 7605 164 1323 Air required (cfm) 70 304 2 53 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 41- wFi htsOft" Page 15 2017-Mar-1015:49:36 9 Right -Suite@ Universal 2017 17.0.19 RSU17939 ACCA ...ed Finals\Knowles Residence Revised Final 3.rup Cale = MJ8 Front Door faces: W 'f Right-J® Worksheet Job: Russell & Linda Knowles ` Date: Mar 10, 2017 AHU-3 Master 3rd By: Tom Platania ProCalcs, LLC P.O. Box882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: ProCalcs@gmail.com Mb: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Master Vest Sitting 2 Exposed wall 10.5 ft 26.0 ft 3 Room height 9.7 ft heat/cool 11.5 ft heat/cool 4 5 Room dimensions Room area 1.0 x 229.5 ft 229.5 ft' 1.0 x 255.3 ft 255.3 ft' Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuh/ft? °F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat FC001 Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 0.095 n 2.97 1.25 0 0 0 0 35 35 103 43 4A5-2ob 0.450 n 14.08 13.71 0 0 0 0 0 0 0 0 4B5-2fb 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 n 0.00 0.00 0 0 0 0 0 0 0 0 11 4B5-2fb 0.450 _n 0.00 _ 0.00 0 0 0 0_ 0 0 0_ 0 W 13A-7.5ocs 0.095 a 2.97 1.25 102 54 160 67 0 0 0 0 10D-b 0.450 a 14.08 20.94 48 44 676 1005 0 0 0 0 10D-b 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 a 14.08 23.71 0 0 0 0 0 0 0 0 4A5-2obd 0.450 a 14.08 42.53 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 a 0.00 0.00 0 0 0 0 0 0 0 0 UV 13A-7.5ocs 0.095 s 2.97 1.25 0 0 0 0 35 35 103 43 10D-b 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s_ 14.08 15.71 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 16.96 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.71 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.71 0 0 0 0 0 0 0 0 4A5-2ob 0.450 s 14.08 15.93 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 s 0.00 0.00 0 _0 0 0 0 0 0 0 W Partition Wall 0.144 s 0.00 0.00 0 0 0 0 0 0 0 0 W 13A-7.5ocs 0.095 w 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 w 2.97 1.25 0 0 0 0 230 174 516 217 1OD-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 1OD-b 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 10D-b 0.450 w 14.08 28.53 0 0 0 0 48 21 676 1370 4A5-2ob 0.450 w 14.08 38.25 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 14.08 23.71 0 0 0 0 8 8 118 199 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 4B5-2fb 0.450 w 0.00 0.00 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 - 0.00 0.00 _ 0 0 0 0 0 0 0 0 P Frm wall, r-11 cav i 0.144 - 0.00 0.00 0 0 0 0 0 0 0 0 q �D Partition Wall 0.144 - 0.00 0.00 0 0 0 0 0 0 0 0 11 DO 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 P Partition Wall 0.101 - 0.00 0.00 0 0 0 0 0 0 0 0 P Partition Wall 0.101 - 0.00 0.00 0 0, 0 0 0 0 0 0 C 16B-21md 0.044 - 1.38 2.37 230 236 316 543 255 255 352 604 C. 17A-Ozd 0.287 0.00 0.00 0 0 0 0 0 0 0 0 F 19A-Obstp 0.368 - 3.75 1.98 0 0 0 0 2 2 6 3 F 22A-tpm 1.180 -_ 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpm 1.180 - 0.00 0.00 0 0 0 0 0 0 0 0 F Flr floor, 140 lb/ft 0.102 0.00 0.00 0 0 0 0 0 0 0 0 F Fir floor, 140 Ib/ft 0.113 0.00 0.00 0 01 0 0 0 0 0 0 6 c)AED excursion -144 386 Envelope loss/gain 1152 1471 1873 2864 12 a) Infiltration 244 62 715 183 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 800 Subtotal (lines 6 to 13) 1396 1534 2588 3847 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1396 1534 2588 3847 15 Duct loads 26% 29% 369 443 26% 29% 684 1112 Total room load 1765 1977 3272 4959 Air required (cfm) 21 79 38 198 Calculations approved bV ACCA to meet all reauirements of Manual J 8th Ed. wriihtsc ft- 2017-Mar-1015:49:36 ACCA Right -Suite® Universal 2017 17.0.19 RSU17939 Page 16 ...ad Finals\Knowles Residence Revised Final 3.rup Calc = MJ8 Front Door faces: W s t• ProCalcs, LLC.. DISCLAIMER The following pages summarize the heat gain and heat loss of the building using the ACCA Manual J8 calculation procedure. The calculations are based on the information given to ProCalcs in the form of drawings, sketches, and interviews. In certain cases, ProCalcs may make assumptions about design conditions that may or may not be accurate for the location of concern. It is the responsibility of the installing HVAC contractor to verify the design conditions before equipment purchase and installation. Any load calculations provided in the following pages are based upon information provided by the party submitting a particular project to ProCalcs. ProCalcs has not and does not independently verify that the data provided to ProCalcs is correct or complete, and any calculations made by ProCalcs are based upon the information provided by third parties. ProCalcs makes no claim that the information given to us is correct or complete. ProCalcs utilizes WrightSoft Residential 15.0 which is an ACCA Certified and ASHRAE recommended computer program to determine the heating and cooling loads presented in this report, and is therefore very accurate. If the information given to ProCalcs is accurate, and the building is built as per the plans submitted, then the load calculations presented in this report can be assumed to be accurate. A licensed mechanical contractor may use these calculations as a starting point in system sizing and selection. ProCalcs does not provide architectural or engineering plans or diagrams for the public or for use by contractors or construction companies as final "construction documents". ProCalcs works with architectural and engineering .firms and with contractors in connection with their designs of heating and air conditioning systems. If the HVAC duct layout installed on -site DOES NOT match the Manual D duct design prepared by ProCalcs, then ProCalcs cannot and will not guarantee the performance of any altered duct design. All branch ducts MUST have adjustable dampers to ensure proper air delivery to each room. Final HVAC sizing and selection should be done by a licensed HVAC contractor. Many factors beyond the scope of this report must be considered prior to final system selection and design, such as: exact equipment availability and selections, system controls and location of controls, system air distribution and cycling, Uniform Building Code requirements, Uniform Mechanical Code requirements, and many other standard design conventions as listed by the American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE). ProCalcs therefore assumes no liability for final equipment selection or final system design. Various modifications to the information provided to ProCalcs may have occurred after this Design Support information was prepared, which would require that this Design Support information be modified in order to be accurate. After reviewing ProCalcs report, and prior to any system purchase or installation, please inform ProCalcs in writing of any changes which may alter the assumptions and calculations contained in this report._