HomeMy WebLinkAboutreview- commentsPlanning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462-6443
PROPERTY INFORMATION
Address: 3800 Anacostia Place
City / State / Zip: Fort Pierce, FI 34949
Parcel #: 2519-800-0012-000/2
Zoning: HIRD
i
REVIEW COMMENTS
1
Owner(s):
Linda M Knowles / Russell J Knowles
Jurisdiction: SAINT LUCIE COUNTY
Lot#: 7 Block:
APPLICATION INFORMATION
Permit Number: 1706-0228 Stories:
Permit Type: BUILDING RESIDENTIAL (SFR UP TO 3 FLOORS)
CONTRACTOR INFORMATION
Contractor Name: Bowers Jeffery A
Business Name: Masterpiece Builders
Business Addr: 915 Se Ocean Blvd #6
City / State / Zip: Stuart, FI 34994
REVIEWS AND COMMENTS
Review Type Status Reviewed By
ADDRESSING ASSIGNMENT COMPLETE. Lydia Galbraith
Comment:
DOCUMENTS MISSING
6/9/2017
Comment:
6/9/2017
Comment:
6/9/2017
Comment:
6/9/2017
Comment:
6/9/2017
Comment:
6/9/2017
Comment:
6/9/2017
Comment:
FRONT COUNTER REVIEW
Comment:
PLANS EXAMINER
REVIEW
Comment:
7/17/2017
7/17/2017 Comment:
PENDING Karen Nielsen
RECORDED NOC
ELECTRICAL SUB
PLUMBING SUB
MECH / HVAC SUB
ROOFING SUB
ERD / VEG. PERMIT
FILLED LANDS AFFIDAVIT
COMPLETE Karen Nielsen
Automatic Sprinkler System? No
Fax Number: 772-283-2770
Email: Jbowers@Masterpiecebuild
ers.Com
Date Started pate Completed Date Released
6/21/2017 6/23/2017 6/23/2017
6/9/2017
6/9/2017 6/9/2017 6/9/2017
INCOMPLETE William Durden 7/14/2017
ENERGY CALC'S SHOWING ON PAGE 1 OF 6 REQUIREMENT OF A ROOF ABSORPTANCE TEST AND A
ROOF EMITTANCE TEST IN ACCORDANCE WITH R405.7.2 OF THE 2014 FLORIDA ENERGY CODE. PLEASE
SUBMIT DOCUMENT INFORMATION FOR THE COOL ROOF OPTION BY THE MANUFACTURER. AND TESTING
FROM INDEPENDENT LABORATORY.
• THE ENERGY CALULATIONS MUST HAVE THE PREPARERS ORIGINAL SIGNATURE PLEASE FURNISH NEW
ENERGY CALULATIONS WITH ORIGINAL SIGNATURE PER 107.1 OF THE 2014 FLORIDA BUILDING CODE
Planning & Development Services
Building 8 Code Regulation Division
2300'Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462-6443
REVIEW COMMENTS
7/17/2017 Comment: • ENERGY CALC'S MUST BE SIGNED BY OWNER OR OWNERS AGENT. SEE CHAPTER 4 SECTION R401.3 OF
THE 2014 RESIDENTIAL ENERGY CODE.
7/17/2017 Comment: • ENERGY CALC'S INFORMATION BLOCK AT THE TOP OF THE PAGE ARE INCOMEPLETE. SEE SECTION
405.4.2 (1) OF THE 2014 FLORIDA ENERGY CODE.
Comment: PAGE 1 OF 6 LIST ONLY ONE U-FACTOR AND SOLAR HEAT GAIN, SHGC FOR MULTIPLE TYPES OF
FENESTRATION.
7/17/2017 - PLEASE SUBMIT THE ENERGY PERFOMANCE SHEETS OR SUBMIT A THE NFRC FENSTRATION
MANUFACTURE CERTIFICATE FOR THE U-FACTOR AND THE SHGC FOR EACH GLAZED OPENING
SHOWING COMPLIANCE WITH CHAPTER 4 SECTION 402.1.1 OF THE 2014 ENERGY CODE FIFTH EDITION.
7/17/2017 Comment: • PLEASE SUBMIT A SOIL REPORT IN COMPLIANCE WITH SECTION R401.4 OF THE 2014 RESIDENTIAL
BUILDING CODE.
7/17/2017 Comment: • PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING
THE SQUARE FOOT INFORMATION. SEE CHAPTER 1 SECTION 107 OF THE 2014 FLORIDA BUILDING CODE.
7/1712017 Comment: PLANS SHOW R-30 CEILING INSULATION, ENERGY CALC'S SHOW R-21 CEILING INSULATION. PLEASE
SUBMIT CORRECTED INFORMATION. SEE SECTION 107 OF THE 2014 FLORIDA BUILDING CODE.
7/17/2017 Comment: PLANS SHOW R-5 CMU WALL INSULATION, ENERGY CALC'S SHOW R-8 CMU WALL INSULATION. PLEASE
SUBMIT CORRECTED INFORMATION. SEE SECTION 107 OF THE 2014 FLORIDA BUILDING CODE.
Comment: • PLEASE SHOW ON THE PLANS THE R-VALUE FOR THE GARAGE TO HOUSE WALL SEPARATION, FROM
7/17/2017 CONDITIONED SPACE TO NON -CONDITIONED SPACE. SEE CHAPTER 4 SECTION R-402 SUBSECTION R-
402.2.13 OF THE 2014 FLORIDA ENERGY CODE.
Comment: - PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND
7/17/2017 APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA
ADMINISTRATIVE CODE
7/17/2017 Comment: • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2014 FLORIDA BUILDING
CODE
7/18/2017 Comment: • PLEASE SHOW ON THE PLANS THE CLEAR NET AREA OFF EACH VENT BEING USED AS HYDRO VENTS IN
ACCORDANCE WITH 322.2.2 OF THE 2014 FLORIDA RESIDENTIAL CODE
7/18/2017 Comment: PLEASE SUBMIT PRODUCT APPROVALS FOR THE FLOOD VENTS. SEE SECTION 322 2014 FLORIDA
RESIDENTIAL BUILDING CODE.
7/18/2017 Comment: FLOOD VENTS ON SHEET A3.3 ARE NOT SHOWN ON PAGE A2.1 PLAN. PLEASE SEE SECTION 107 OF THE
2014 FLORIDA BUILDING CODE.
Comment: PARTS OF THE FLOOD VENTS SHOWN ON PLANS ARE LOCATED ABOVE BFE, PLEASE SEE FEMA
7/18/2017 TECHNICAL BULLETIN 1, PAGE 14 HEIGHTS AND OPENING ABOVE GRADE, PLEASE NOTE THAT THE
OPENINGS OR THOSE PORTIONS THAT COUNT TOWARDS THE REQUIRED NET OPEN AREA MUST BE
LOCATED BELOW THE BFE.
7/18/2017 Comment: PLEASE SUBMIT PRODUCT INFORMATION FOR THE FLOOD VENTS SIZING AND REQUIREMENTS SECTION
107 OF THE 2014 FLORIDA BUILDING CODE
7/18/2017 Comment: THE SHEET A 2.1 C FLOOD VENTS NOTE STATES SEE STRUCTURAL FOR SIZING. NO FLOOD VENTS
SIZING SHOWN IN STRUCTURAL DRAWINGS. SEE SECTION 107 2014 FLORIDA BUILDING CODE.
7/18/2017 Comment: SHEET S1 .0 FLOOD VENT SIZES DO NOT MATCH SHEET A 3.3 FOR THE FLOOD VENT SIZES. SEE SECTION
107 2014 FLORIDA BUILDING CODE.
Comment: PLEASE CLOUD ON SHEET S 13.0 THE LOCATION OF THE LOWEST STRUCTURAL BEAM FOR
7/18/2017 CLARIFICATION OF THE LOWEST HORIZONTAL STRUCTURAL MEMBER. SEE CHAPTER 3 SECTION R322.3.2
OF THE 2014 FLORIDA RESIDENTIAL BUILDING CODE.
ZONING REVIEW INCOMPLETE Lydia Galbraith 6/20/2017
6/21/2017 Comment: PLEASE PROVIDE ONE ELEVATION PAGE WITH TRUE ELEVATIONS STARTING WITH GRADE ALL THE WAY
UP. PLEASE CLEARLY INDICATE THE BOTTEM OF THE STRUCTURAL BEAM.
Comment: FEMA DETERMINES THE ELEVATION OF THE FIRST STRUCTURAL BEAM. HOWEVER, THEIR SCHEDULE IS
6/21/2017 IN NGVD. PLEASE INDICATE ON THE SITE PLAN OR ON THE SURVEY THE CONVERTION RATE FROM NGVD
TO NAVD. WE NEED TO BE ABLE TO CHECK IF THE BEAM IS AT THE CORRECT ELEVATION AND ALSO IT
WILL BE THE STARTING POINT FOR THE HEIGHT CALCULATION. MIN. REQUIREMENT FDEP IS 17, NGVD.
Comment: PLEASE BE AWARE THAT WE WERE NOT ABLE TO COMPLETE THE ZONING REVIEW DUE TO MISSING
6/21/2017 INFORMATION. THE PLANS WILL PROCEED THRU THE'REVIEW PROCESS. HOWEVER, ADDITIONAL
COMMENTS MIGHT BE APPLICABLE AFTER REVIEWING THE MISSING INFORMATION.
6/21/2017 Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS
EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.