Loading...
HomeMy WebLinkAboutreview- commentsPlanning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462-2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 3800 Anacostia Place City / State / Zip: Fort Pierce, FI 34949 Parcel #: 2519-800-0012-000/2 Zoning: HIRD i REVIEW COMMENTS 1 Owner(s): Linda M Knowles / Russell J Knowles Jurisdiction: SAINT LUCIE COUNTY Lot#: 7 Block: APPLICATION INFORMATION Permit Number: 1706-0228 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 3 FLOORS) CONTRACTOR INFORMATION Contractor Name: Bowers Jeffery A Business Name: Masterpiece Builders Business Addr: 915 Se Ocean Blvd #6 City / State / Zip: Stuart, FI 34994 REVIEWS AND COMMENTS Review Type Status Reviewed By ADDRESSING ASSIGNMENT COMPLETE. Lydia Galbraith Comment: DOCUMENTS MISSING 6/9/2017 Comment: 6/9/2017 Comment: 6/9/2017 Comment: 6/9/2017 Comment: 6/9/2017 Comment: 6/9/2017 Comment: 6/9/2017 Comment: FRONT COUNTER REVIEW Comment: PLANS EXAMINER REVIEW Comment: 7/17/2017 7/17/2017 Comment: PENDING Karen Nielsen RECORDED NOC ELECTRICAL SUB PLUMBING SUB MECH / HVAC SUB ROOFING SUB ERD / VEG. PERMIT FILLED LANDS AFFIDAVIT COMPLETE Karen Nielsen Automatic Sprinkler System? No Fax Number: 772-283-2770 Email: Jbowers@Masterpiecebuild ers.Com Date Started pate Completed Date Released 6/21/2017 6/23/2017 6/23/2017 6/9/2017 6/9/2017 6/9/2017 6/9/2017 INCOMPLETE William Durden 7/14/2017 ENERGY CALC'S SHOWING ON PAGE 1 OF 6 REQUIREMENT OF A ROOF ABSORPTANCE TEST AND A ROOF EMITTANCE TEST IN ACCORDANCE WITH R405.7.2 OF THE 2014 FLORIDA ENERGY CODE. PLEASE SUBMIT DOCUMENT INFORMATION FOR THE COOL ROOF OPTION BY THE MANUFACTURER. AND TESTING FROM INDEPENDENT LABORATORY. • THE ENERGY CALULATIONS MUST HAVE THE PREPARERS ORIGINAL SIGNATURE PLEASE FURNISH NEW ENERGY CALULATIONS WITH ORIGINAL SIGNATURE PER 107.1 OF THE 2014 FLORIDA BUILDING CODE Planning & Development Services Building 8 Code Regulation Division 2300'Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462-2172 Fax:(772)462-6443 REVIEW COMMENTS 7/17/2017 Comment: • ENERGY CALC'S MUST BE SIGNED BY OWNER OR OWNERS AGENT. SEE CHAPTER 4 SECTION R401.3 OF THE 2014 RESIDENTIAL ENERGY CODE. 7/17/2017 Comment: • ENERGY CALC'S INFORMATION BLOCK AT THE TOP OF THE PAGE ARE INCOMEPLETE. SEE SECTION 405.4.2 (1) OF THE 2014 FLORIDA ENERGY CODE. Comment: PAGE 1 OF 6 LIST ONLY ONE U-FACTOR AND SOLAR HEAT GAIN, SHGC FOR MULTIPLE TYPES OF FENESTRATION. 7/17/2017 - PLEASE SUBMIT THE ENERGY PERFOMANCE SHEETS OR SUBMIT A THE NFRC FENSTRATION MANUFACTURE CERTIFICATE FOR THE U-FACTOR AND THE SHGC FOR EACH GLAZED OPENING SHOWING COMPLIANCE WITH CHAPTER 4 SECTION 402.1.1 OF THE 2014 ENERGY CODE FIFTH EDITION. 7/17/2017 Comment: • PLEASE SUBMIT A SOIL REPORT IN COMPLIANCE WITH SECTION R401.4 OF THE 2014 RESIDENTIAL BUILDING CODE. 7/17/2017 Comment: • PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING THE SQUARE FOOT INFORMATION. SEE CHAPTER 1 SECTION 107 OF THE 2014 FLORIDA BUILDING CODE. 7/1712017 Comment: PLANS SHOW R-30 CEILING INSULATION, ENERGY CALC'S SHOW R-21 CEILING INSULATION. PLEASE SUBMIT CORRECTED INFORMATION. SEE SECTION 107 OF THE 2014 FLORIDA BUILDING CODE. 7/17/2017 Comment: PLANS SHOW R-5 CMU WALL INSULATION, ENERGY CALC'S SHOW R-8 CMU WALL INSULATION. PLEASE SUBMIT CORRECTED INFORMATION. SEE SECTION 107 OF THE 2014 FLORIDA BUILDING CODE. Comment: • PLEASE SHOW ON THE PLANS THE R-VALUE FOR THE GARAGE TO HOUSE WALL SEPARATION, FROM 7/17/2017 CONDITIONED SPACE TO NON -CONDITIONED SPACE. SEE CHAPTER 4 SECTION R-402 SUBSECTION R- 402.2.13 OF THE 2014 FLORIDA ENERGY CODE. Comment: - PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND 7/17/2017 APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE 7/17/2017 Comment: • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE 7/18/2017 Comment: • PLEASE SHOW ON THE PLANS THE CLEAR NET AREA OFF EACH VENT BEING USED AS HYDRO VENTS IN ACCORDANCE WITH 322.2.2 OF THE 2014 FLORIDA RESIDENTIAL CODE 7/18/2017 Comment: PLEASE SUBMIT PRODUCT APPROVALS FOR THE FLOOD VENTS. SEE SECTION 322 2014 FLORIDA RESIDENTIAL BUILDING CODE. 7/18/2017 Comment: FLOOD VENTS ON SHEET A3.3 ARE NOT SHOWN ON PAGE A2.1 PLAN. PLEASE SEE SECTION 107 OF THE 2014 FLORIDA BUILDING CODE. Comment: PARTS OF THE FLOOD VENTS SHOWN ON PLANS ARE LOCATED ABOVE BFE, PLEASE SEE FEMA 7/18/2017 TECHNICAL BULLETIN 1, PAGE 14 HEIGHTS AND OPENING ABOVE GRADE, PLEASE NOTE THAT THE OPENINGS OR THOSE PORTIONS THAT COUNT TOWARDS THE REQUIRED NET OPEN AREA MUST BE LOCATED BELOW THE BFE. 7/18/2017 Comment: PLEASE SUBMIT PRODUCT INFORMATION FOR THE FLOOD VENTS SIZING AND REQUIREMENTS SECTION 107 OF THE 2014 FLORIDA BUILDING CODE 7/18/2017 Comment: THE SHEET A 2.1 C FLOOD VENTS NOTE STATES SEE STRUCTURAL FOR SIZING. NO FLOOD VENTS SIZING SHOWN IN STRUCTURAL DRAWINGS. SEE SECTION 107 2014 FLORIDA BUILDING CODE. 7/18/2017 Comment: SHEET S1 .0 FLOOD VENT SIZES DO NOT MATCH SHEET A 3.3 FOR THE FLOOD VENT SIZES. SEE SECTION 107 2014 FLORIDA BUILDING CODE. Comment: PLEASE CLOUD ON SHEET S 13.0 THE LOCATION OF THE LOWEST STRUCTURAL BEAM FOR 7/18/2017 CLARIFICATION OF THE LOWEST HORIZONTAL STRUCTURAL MEMBER. SEE CHAPTER 3 SECTION R322.3.2 OF THE 2014 FLORIDA RESIDENTIAL BUILDING CODE. ZONING REVIEW INCOMPLETE Lydia Galbraith 6/20/2017 6/21/2017 Comment: PLEASE PROVIDE ONE ELEVATION PAGE WITH TRUE ELEVATIONS STARTING WITH GRADE ALL THE WAY UP. PLEASE CLEARLY INDICATE THE BOTTEM OF THE STRUCTURAL BEAM. Comment: FEMA DETERMINES THE ELEVATION OF THE FIRST STRUCTURAL BEAM. HOWEVER, THEIR SCHEDULE IS 6/21/2017 IN NGVD. PLEASE INDICATE ON THE SITE PLAN OR ON THE SURVEY THE CONVERTION RATE FROM NGVD TO NAVD. WE NEED TO BE ABLE TO CHECK IF THE BEAM IS AT THE CORRECT ELEVATION AND ALSO IT WILL BE THE STARTING POINT FOR THE HEIGHT CALCULATION. MIN. REQUIREMENT FDEP IS 17, NGVD. Comment: PLEASE BE AWARE THAT WE WERE NOT ABLE TO COMPLETE THE ZONING REVIEW DUE TO MISSING 6/21/2017 INFORMATION. THE PLANS WILL PROCEED THRU THE'REVIEW PROCESS. HOWEVER, ADDITIONAL COMMENTS MIGHT BE APPLICABLE AFTER REVIEWING THE MISSING INFORMATION. 6/21/2017 Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.