Loading...
HomeMy WebLinkAbout1705-0571 NOA - BELLA HIGH ' S TILETHESE PLANS AND ALI. PROPOSED MIQKn _ ARE SURD CT TO PAP-1 C(1 '�*GTIOHS 4 REOUIRE0 LT Mr.10 ICJ, �C`t+ ��iI�F�� M1AM1 MAY BE Nfl-casokily IN E'R !O MIAMI-DADE COUNTY C®tt1Pl;yWITH ���� rQAF,e; PRODUCT805 SW26 Street, Ro ON mOL I 08 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Entegra Roof Tile, LLC U S� 11 lC �4. �6 • �� �e,5'p 1289 NE 91 Ave Okeechobee, FL 34972 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHD may immediately revoke, modify, or suspend the use of such product or material -within their jurisdiction. RER reserves the right to revoke this acceptance, if it.is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Bella "High S" Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. CONMED PASTENEaS Op MACH MENTS This NOA renews NOA No. 14-1120.05 and consists of pages 1 through 5. ARE THE RESpONSISILITY The submitted documentation was reviewed by Gaspar J Rodriguez. of THE o n. CONTRACTOR OFRECORD A G. ® S . LUCIE COUNTY BUILDING DIVISION REVIEWED FOR CO Joe REVIEWED Y DATE P NS AND Ni MIT MUST BE KEPT ON JOEJ On NO IN3PGCTION WILD PA MAMI2 NOA No.: 16-0112.06 Expiration Date: 07/13/21 Approval Date: 02/25/16 Page 1 of 5 L ROOFING ASSEMBLY APPROVAL Cateizory Roofing Sub -Category: Roofing Tiles Material: Concrete Deck Type: Wood 1. SCOPE This approves a roofing system using Entegra Bella "High S" concrete roof file as manufactured in Okeechobee, FL and described in Section 2 of this Notice of Acceptance. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Bella "High S" Length =16 %2' TAS 112 High profile, interlocking, extruded concrete roof file Width =13 '/a" Type 2 equipped with two nail holes. For mechanical, mortar Thickness ='/2" Class H or adhesive set applications. Trim Pieces 1= varies TAS 112 Accessory trim, concrete roof pieces for use at hips, w = varies rakes, ridges and valley terminations. varying thickness 2.1 MANUFACTURING LOCATION 1. Okeechobee, FL 2.2 EVIDENCE SUBMITTED Test Asen Test Identifier Test Name/Report Date The Center for Applied Engineering, 25-7094-(3, 6 & 9) Static Uplift Testing Oct. 1994 Inc. TAS 102 The Center for Applied Engineering, 25-7120-(1 & 2) Static Uplift Testing Nov. 1994 Inc. TAS 102 The Center for Applied Engineering, 25-7183-(3 & 4) Static Uplift Testing Feb. 1995 Inc. TAS 102 The Center for Applied Engineering, 25-7214-(3, 4, &7) Static Uplift Testing March, 1995 Inc. TAS 102 The Center for Applied Engineering, 25-78044 Static Uplift Testing Sep. 1996 Inc. TAS 102 Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998 Testing Services TAS 101 Celotex Corporation 520191-2-1 Static Uplift Testing March 1999 Testing Services TAS 101 Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999 NOA No.: 16-0112.06 MuaMaoaoe COUNTY s Expiration Date: 07/13/21 Approval Date: 02/25/16 Page 2 of 5 2.2 EVIDENCE SUBMITTED Test Aaencv Test Identifier Test Name/Repo rt Date Walker Engineering, Inc. Calculations Restoring Moment June 2007 IBA Consultants, Inc. 2421-94 ASTM C 1167 June 2006 American Test Lab of South Florida RT1210.03-15 TAS 112-95 Dec 2015 3. LmTATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may be required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Miami -Dade Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Entegra Sales, Inc.'s Bella "High S" concrete roof tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length-1 (ft) Width-w (ft) Bella "High S" Tile 10.5 1.375 1.08 Table 2: Aerodynamic Multipliers - A (ft3) Tile Profile A (ft3) Batten Application A (ft3) Direct Deck Application Bella "High S" Tile 0.349 0.378 Table 3: Restoring Moments due to Gravity - M9 (ft-lbf) Tile Profile 2":12" 32':12" 411:12" 5":12" 6":12" Greater than 7":12" Bella "High S" Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 6.19 6.89 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33 5.50 6.13 NOA No.: 16-0112.06 MIAMFDAD, COUNTY Expiration Date: 07/13/21 Approval Date: 02/25/16 Page 3 of 5 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min.19/32" plywood) Battens Bella "High S" Tile 2-10d Ring Shank Nails 28.6 41.2 19.4 1-10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2-10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 #8 Screw 20.7 20.7 18.1 2 #8 Screw 43.2 43.2 29.8 1-10d Smooth or Screw Shank Nail Field Clip) 23.1 23.1 19.0 1-10d Smooth or Screw Shank Nail Eave Clip) 29.3 29.3 24.0 2-10d Smooth or Screw Shank Nails Field Clip) 27.6 27.6 38.6 2-10d Smooth or Screw Shank Nails Eave Clip) 38.1 38.1 41.8 2-10d Ring Shank Nails' 33.1 48.1 50.9 1. Installation with a 4" the headlap and fasteners are located a min. of 2Y2" from head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Bella "High S" Tile Adhesive 29.32 1 See manufactures component approval for installation requirements. 2 Flexible Products Company TileBond Average weight per patty 10.7 grams. 3M- 2-Component Foam Roof Tile Adhesive AH-160 Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistan Bella "High S" Tile 3W 2-Component Foam Roof Tile Adhesive AH-160 66.53 3M. 2-Component Foam Roof Tile Adhesive AH-160 38.r 3 Large patty placement of 63 rams of 3W 2-Component Foam Roof Tile Adhesive AH-160. 4 Medium patty placement of 24 rams of 3W 2-Component Foam Roof Tile Adhesive AH-160. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Bella "High S" Tile Mortar Sets 24.5 5 Tile -rite Roof Tile Mortar. NOA No.:16-0112.06 Expiration Date: 07/13/21 Approval Date: 02/25/16 Page 4 of 5 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen in detail below, or following statement: "Miami -Dade County Product Control Approved". OR v.�7ENTEGRR v.�7 ENTEGRA SALES BELLA "HIGH S" CONCRETE TILE LABEL (LOCATED UNDERNEATH TILE) BUILDING PERMIT REQUIREMENTS: As required by the Building Official or the applicable Building Code in order to properly evaluate the installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit. PROFILE DRAWING END OF THIS ACCEPTANCE NOA No.: 16-0112.06 Expiration Date: 07/13/21 Approval Date: 02/25/16 Page 5 of 5