Loading...
HomeMy WebLinkAbout1705-0571 NOA- FOAM ROOF TILE ADHESIVEi MIAMI-DAM MM DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE I 3M Company 3M Center Building 0220-05-E-06 St. Paul, MN. 55144-1000 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.zov/economv SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3M Foam Roof Tile Adhesive RTA 1 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be ;displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA# 14-0805.02 and consists of pages 1 through 8. P t& ff The submitted documentation was reviewed by Alex Tigera.FILE CUU, COUNTY NOA No.: 15-1201.04 MIAMI•DADE Expiration Date: 01/03/21 Approval Date: 12/31/15 Page 1 of 8 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3M Foam Roof Tile Adhesive RTA-1 as manufactured by 3M Company as described below in this Notice of Acceptance. For the locations where the pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127. For use with approved flat, low, and high profile roof file systems using 3M Foam Roof Tile Adhesive RTA-1. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Specifications 3M Foam Roof Tile N/A TAS 101 Adhesive RTA-1 PRODUCTS MANUFACTURED BY OTHERS: Product Description Single component polyurethane foam roof file adhesive. Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of 3M Foam Roof Tile Adhesive RTA-1 roof file adhesive. MANUFACTURING LOCATION: 1. Norton, OH. PHYSICAL PROPERTIES: ProRe Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2842 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 Results 1.95 lbs./ft 3 7.8 psi 15 PSI Parallel to rise 4.6 Lbs./Fe 1.94 Perm / Inch +0.89% Volume Change @ 700 C., 2 Weeks 54.1% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 15-1201.04 MAMI-DADe COUNTY Expiration Date: 01/03/21 FAURPI'MI Approval Date: 12/31/15 Page 2 of 8 EVIDENCE SUBNIITTED: Test ALyenCV Test Identifier Test Name/Reuort Date Southwest Research Institute 01-1208-025 ASTM E 108 06/16/98 PRI Construction Materials FOP-009-02-10 Physical Properties 12/14/10 Technologies, Inc. FOP-009-02-01 TAS-101 11/8/10 FOP-009-02-02 TAS-101 11/4/10 FOP-009-02-03 TAS-101 11/8/10 FOP-009-02-04 TAS-101 11/8/10 FOP-009-02-05 TAS-101 11/8/10 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. 3M Foam Roof Tile Adhesive RTA-1 can be used with flat, low, medium and high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 3M Foam Roof Tile Adhesive RTA-1 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. F _W 2 F'= MS 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 15-1201.04 MIAMI-DADE COUNTY Expiration Date: 01/03/21 Approval Date: 12/31/15 Page 3 of 8 INSTALLATION: 1. 3M Foam Roof Tile Adhesive RTA-1 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of 3M Foam Roof Tile Adhesive RTA-1. 2. 3M Foam Roof Tile Adhesive RTA-1 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3M Foam Roof Tile Adhesive RTA-1 shall provide sufficient attachment resistance to meet or exceed the resistance values determined in compliance with Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3M Foam Roof Tile Adhesive RTA-1 roof tile adhesive and its components shall be installed in accordance with Roofing Application Standard RAS 120, and Fomo Products, Inc. 3M Foam Roof Tile Adhesive RTA- 1 Operating Instruction and Maintenance Booklet 4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. 5. Tiles must be adhered in freshly applied adhesive. Tile must be set within 4 minutes after 3M Foam Roof Tile Adhesive RTA-1 has been dispensed. 6. 3M Foam Roof Tile Adhesive RTA-1 placement shall be in accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Typical Placement Detail Weight per paddy (grams) # 1 12 - iece arrel # 2 12 Flat, Low & Hi ro e Hign ro i e LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 15-1201.04 CMIAMMADEcounmr Expiration Date: 01/03/21 Approval Date: 12/31/15 Page 4 of 8 ADHESIVE PLACEMENT DETAILS PLACEMENT DETAIL # 1 FLAT PROFILE 2-1 41 packiY we tile NOA No.: 15-1201.04 Expiration Date: O1/03/21 Approval Date: 12/31/15 Page 5 of 8 PLACEMENT DETAIL # 1(CONT... ) 'Start ovedodc side paddy c the course line. Ea/nre art underiodc side paddy appradmately 1" above tile Closure course line. LOW PROFILE NOA No.: 15-1201.04 MwYn•�we couNrir Expiration Date: 01/03/21 APPROVED Approval Date: 12/31/15 Page 6 of 8 Pan of I Eave omw line --\ / PLACEMENT DETAII. # 2 K 107MM"11,70 • 1 - •• cta• • t • •:••�- Start paddy ux6mdh pan potion of file approoamately 1" above file oou'se line. HIGH PROFILE NOA No.: 15-1201.04 MIAMI•DADE COUNTY Expiration Date: 01/03/21 �Fjmmaqrjqm Approval Date: 12/31/15 Page 7 of 8 I J PLACEMENT DETAIL # 2 (CONT...) IN ` Two (2) - 7' oblong paddles side by side w*der pan tiles. One (1) -7" paddy -an each side raider oower files. Y Two (2) -10' oblong paddies side by side tinder rm tiles . (em ==only). Mortar eme dosm 2-PIECE BARREL PROFILE END OF THIS ACCEPTANCE NOA No.: 15-1201.04 QMIAMMI-MADEuNrr Expiration Date: 01/03/21 Approval Date: 12/31/15 Page 8 of 8