HomeMy WebLinkAbout1707-0182 ENERGY EFFICIENCY CODEFORM R405-2014 4 l 2
FLORIDA ENERGY EFFICIENCY C UIL NSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Wright Residence
Builder Name: Mike DiFranc s o
���� �1®pJy�
Street: 4609 Pinetree Dr
Permit Office: St Lucie Countyl
•
City, State, Zip: Fort Pierce , FL , 34982
Permit Number: 1707-0182
Owner: Wdgth Resdience.
Jurisdiction: 611000
Design Location: FL, ST_LUCIE_CO_INTL
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1354.7 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Polystyrene Bead
AggtR=0.0 1061.30 ftz
b. Frame - Wood, Adjacent
R=13.0 293.33 ftz
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 3
d. N/A
R= ftz
10. Ceiling Types (1476.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 1476.00 ftz
6. Conditioned floor area above grade (ftz) 1476
b. N/A
R= ftz
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz
11. Ducts
R ftz
7. Windows(126.5 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 250
a. U-Factor: Sgl, U=0.37 66.50 ftz
SHGC: SHGC=0.22
b. U-Factor: Sgl, U=0.35 60.00 ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.20
a. Central Unit
22.6 SEER:15.00
c. U-Factor: N/A ftz
SHGC:
13..Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftz
a. Electric Heat Pump
23.0 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 5.794 ft.
Area Weighted Average SHGC: 0.211
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1476.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 1476.00 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
15. Credits
CF, Pstat
Glass/Floor Area: 0.086 Total Proposed Modified Loads: 49.29
PASS
Total Baseline Loads: 49.31
I hereby certify that the plans and specifications covered by
Review of the plans and
O�TrtIE ST,4?�
this calculation are in compliance the Florida E y
specifications covered by this
ti ,� Off,
Code.
calculation indicates compliance
with the Florida Energy Code.
Ohs
PREPARED BY:
Before construction is completed
DATE: 0 ZZ
this building will be inspected for
compliance with Section 553.908
0
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
COD
with the Florida Energy Code.
y�rE'
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: '21-Z( - '7.o n
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 this
project requires an envelope leakage test report with envelope leakage no greater than 5.0 ACH50 (R402.4.1.2).
8/21/2017 1:40 PM - EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2014
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
. New/Existing:
Comment:
Wright Residence
User
Wdgth Resdience
1
Mike DiFrancesco
St Lucie County
611000
Single-family
New (From Plans)
Bedrooms: 3
Conditioned Area: 1476
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type: Street Address
Lot #
Block/SubDivision:
PlatBook:
Street: 4609 Pinetree Dr
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34982
•
CLIMATE
/
V Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 2 39 90
70
75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1476 11808
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
1476 11808 Yes 4
3
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
Main 174 ft 0
1476 ft2
---- 0 0 1
ROOF
/
v #
Roof Gable Roof
Type Materials Area Area Color
Solar
Absor.
SA Emitt Emitt Deck Pitch
Tested Tested Insul. (deg)
1
Hip
Metal 1599 ft2 0 ft2 Unfinishe
0.35
No 0.4 No 20 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented 0 1476 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Unvented)
Main 0 Blown
1476 ft2 0 Wood
8/21/2017 1:40 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2014
WALLS
Adjacent
Cavity Width Height
Sheathing Framing
Solar
Below
Omt
Space
To Wall Type_
lFt In Et
In Area
R-Malue
Fraction
AhSoc
Grade%
1
N
Exterior Concrete Block - Polystyren Main
0 30 8
240.0 ft2
0
0
0.75
0
2
E
Exterior Concrete Block - Polystyren Main
0 28 8
224.0 ft2
0
0
0.75
0
_ 3
E
Garage Frame - Wood Main
13 21 8 8
173.3 ft2
0.23
0
0.75
0
4
S
Garage Frame - Wood Main
13 15 8
120.0 ft2
0.23
0
0.75
0
5
S
Exterior Concrete Block - Polystyren Main
0 15 8 8
125.3 ft2
0
0
0.75
0
6
W
Exterior Concrete Block - Polystyren Main
0 33 8
264.0 ft2
0
0
0.75
0
_ 7
W
Exterior Concrete Block - Polystyren Main
0 26 8
208.0 ft2
0
0
0.75
0
DOORS
#
Omt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In •
Ft In
1
E Insulated Main
None
.4 3
6 8
20 ft2
2
E Insulated Main
None
.4 2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Omt ID Frame Panes NFRC
U-Factor SHGC
Area Depth
Separation
Int Shade
Screening
1
N 1 Vinyl Single (Clear) Yes
0.37 0.22
15.0 ft2 2 ft 0 in
1 ft 0 in
None
None
2
N 1 Vinyl Single (Clear) Yes
0.37 0.22
15.0 ft2 2 ft 0 in
1 ft 0 in
None
None
3
E 2 Vinyl . Single (Clear) Yes
0.37 0.22
15.0 ft2 2 ft 0 in
1 ft 0 in
None
None
4
E 2 Vinyl Single (Clear) Yes
0.37 0.22
15.0 ft2 2 ft 0 in
1 ft 0 in
None
None
5
S 5 Vinyl Single (Clear) Yes
0.37 0.22
6.5 ft2 2 ft 0 in
1 ft 0 in
None
None
6
W 7 Vinyl Single (Clear) Yes
0.35 0.2
20.0 ft2 10 ft 0 in
1 ft 0 in
None
None
7
W 7 Vinyl Single (Clear) Yes
0.35 0.2
40.0 ft2 10 ft 0 in
1 ft 0 in
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
504 ft2 504 ft2
58 ft
8 ft
1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000254
984 54.02 101.59 .1906
5
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump None
HSPF:8.5
23 kBtu/hr
1
sys#1
8/21/20171:40 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2014
COOLING SYSTEM
#
System Type
Subtype
Efficiency
� Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit
None
SEER: 15
22.6 kBtu/hr 678 cfm
0.75
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1
Electric
None
Garage
0.98 40 gal
60 gal
120 deg
None
'
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
' Cert
# Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftz
DUCTS
/
— Supply —
— Return—
Air
CFM 25
CFM25
HVAC #
V #
Location R-Value Area
Location
Area Leakage Type
Handier
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 250 ftz
Attic
73.8 ftz Default Leakage
Garage
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
Heatin
Feb
Jan Feb
Mar
Mar
r
AA�ppr
Ma [XI Jun X Jul
May [ Jun Jul
X Au
AuSeP
X Se
WOct
Oct
Nov
Nov
H
Dec
Dec
Ventin
Jan Feb
X Mar
X
r
Ma [ Jun Jul
Aug
Se
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating(WD)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
8/21/20171:40 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows** Description
a. U-Factor: Sgl, U=0.37
SHGC: SHGC=0.22
b. U-Factor: Sgl, U=0.35
SHGC: SHGC=0.20
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
4609 Pinetree Dr, Fort Pierce, FL, 34982
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Polystyrene Bead AggiR=0.0
1061.30 ft2
b. Frame - Wood, Adjacent
R=13.0
293.33 ft2
1
c. N/A
R=
ft2
3
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
No
a. Roof Deck (Unvented)
R=20.0
1476.00 ft2
1476
b. N/A
R=
ft2
c. N/A
R=
ft2
Area
11. Ducts
R f12
66.50 ft2
a. Sup: Attic, Ret: Attic, AH: Garage
6 250
60.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
22.6
SEER:15.00
ft2
5.794 ft.
0.211
8. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1476.00 ft2
b. N/A R= ft2
c. N/A R= ft2
13. Heating systems
a. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant featuyes.
Builder Signature: n �`/ Date: -?--Z/ _20f7
Address of New Home:q,�g� ��h �� �,�,� CitylFL Zip: -ram P �,, , Fc 3
kBtu/hr Efficiency
23.0 HSPF:8.50
Cap: 40 gallons
EF: 0.98
CF, Pstat
IV 0- " - .c+
s �0oD wE �`��
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
8/21/2017 1:40 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name:
Wright Residence
Builder Name:
Mike DiFrancesco
Street:
4609 Pinetree Dr
Permit Office:
St Lucie County
City, State, Zip:
Fort Pierce , FL , 34982
Permit Number:1707-0182
• Design Location:
FL, ST LUCIE_CO_INTL
Jurisdiction:
611000
Cond. Floor Area::
1476 sq.ft.
Cond. Volume:
11808 cu ft.
Envelope Leakage Test Results
Regression Data:
C:
n:
Single or Multi Point Test Data
A
HOUSE PRESSURE
FLOW:
1
Pa
cfm
2
Pa
cfm
3
Pa
cfm
4
Pa
cfm
5
Pa
cfm
6
Pa
cfm
Leakage Characteristics
CFM(50):
ELA:
EgLA:
ACH:
SLA:
ACH(50)
* For prescriptive projects, tested leakage must be
<=7 ACH(50). For performance projects, tested
leakage must be <= the ACH(50) shown on Form
R405-2014 for this project.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in
Climate Zones 1 and 2. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(% (g), or (i) or an approved
third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be
performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other
infiltration control measures;
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration
control measures;
3. Interior doors, if installed at the time of the test, shall be open;
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and
6. Supply and return registers, if installed at the time of the test, shall be fully open.
I hereby certify that the above envelope leakage
'performance results demonstrate compliance
with Florida Energy Code requirements in
.accordance with Section R402.4.1.2.
SIGNATURE:
PRINTED NAME:
DATE:
Testing shall be conducted by either
individuals as defined in Section
553.993(5) or (7), Florida Statutes or
individuals licensed as set forth in
Section 489.105(3)(f), (g), or (i) or an
approved third party. A written report
of the results of the test shall be
signed by the third party conducting
the test and provided to the code
BUILDING OFFICIAL:
DATE:
THE ST,�?
0
o _ a
8121120171.41 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1