Loading...
HomeMy WebLinkAboutKSM SOIL COMPACTION REPORT 9-13-1709/01/2017 14:52 7725896469 KSM ENGINEERING PAGE 01/02 i1 �71Y� KELLER, SCHLEIC HER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P.O. BOX 78-1377 SEBASTIAN,. FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-BB76 E-Mail: KSMOKSMENGaINEERING-NET ST. LUCIE (772) 229-9093 C-A.: 5693 FAX (772) 589-6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED August 31, 2017 PERMIT # �1`706047- CONTRACTOR St. Lucie Site Development JOB LOCATION 5010 Palmetto Drive Port St Lucie, Florida KSM JOB # : 172576-3d/MH/cv ITEM TESTED • Compacted Foundation Fill for the House Pad - Re -Test TEST LOCATION DEPTH " PEN DRY - MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. N.E. 011,1211 51 111.7 112.8 99.0 2. S. E. 1,50 110.4 97.9 3. Center 50 109.5 97.2 4. N.W. 51 111.3 98.7 5. S.W. 52 112.6 99.8 Soil Description: Brown Sand with Shell Fragments In Place Moisture: 11.2 Percent Optimum Moisture: 11.0 Percent Max. Dry Density: 112.8 P.G.F. @ Test Locations The Density & Penetrometer Readings Indicate the Degree of Compaction Meets Minimum Required for Un jqTV, Foundation. ;�ad91&X;Dken to Natural Grade. ri r Moisture - % of Dry Weight RECEIVED SER 012017 ►�fi611lhel h(�yahao.com . Iptq: ti�ie County Building Department Kcllcr, RE_; 37293 / SI Lir... Nb.. 880 / Julie E. Kellcr, PE.: 68365 09/01/2017 14:52 7725896469 KSM ENGINEERING PAGE 02/02 0 KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P.O_ BOX 78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN (772) 589.0712 PALM BEACH 846-7445 www.kgmen ineerin net MELBOURNE (321) 768-8488 PAX (56845-8876 8$76 E-Mail: KSMOKSMENGINEERING.NET 5T. LUCIE (772) 229-9093 C.A.: 5693 FAX (772) 589-6469 SOIL COMPACTION REPORT ASTM D 1557 and .A►STM D 2922 DATE TESTED August 31, 2017 PERMIT # 1706-0247 CONTRACTOR St. Lucie Site Development JOB LOCATION 5010 Palmetto Drive Port St Lucie, Florida KSM JOB # : 172576-4d/MH/ev ITEM TESTED Compacted Foundation Fill for the Detached Garage Pad - Re -Test, TEST LOCATION DEPTH *'PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. N. E. 0" - 12" 50 107.2 110.3 97.2 2. Center " 50 105.3 , 95.5 3, S_W. " 50 106.0 ,. 96.1 Soil Description: Brown Sand with Shell Fragments In Place Moisture: 10.8 Percent Optimum Moisture: 12.0 Percent Max. Dry Density: 110,3 P.G.F. @ Test Locations The Density & Penetrometer Readings Indicate the Degree of Compaction Meets Minimum Required fK%UA%=�""nkein undation. to Natural Grade. W E I I I I I I H T' I I I I P F I I I I 108.0 R Y I I I I '107.0 9 10 11 12 13 14 15 Moisture - % of Dry Weight OF " _ t a7yahoo.com 1AL ucie County Building Department RL)nald G. Keller. P.E.: 37293 1,91 1 ic. No.: 860 / Julie E. Keller,, PE.: 68366