Loading...
HomeMy WebLinkAboutSEWAGE"Cer4ED APPLICATION #:AP1293320 STATE OF FLORIDA JM 1 g Tp1g PERMIT #:56-SF-1767365 DEPARTMENT OF HEALTH DOCUMENT #:F11191074 ONSITE SEWAGE TREATMENT 1 p,"1!Wp=etYSTEM 06�02�2017 CONSTRUCTION INSPECTION ANIStiE i5PROVAL DATE PAID: FEE PAID:515.00 I RECEIPT #:56-PID-3257336 APPLICANT: Tom Huddleston AGENT: Brian Helseth PROPERTY ADDRESS: 5010 Palmetto Dr Fort Pierce, FL 34982 LOT: 33& 34 SUBDIVISION: BLOCK: 26 Indian River Estates ID#: 3402-606-0188-000-4 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1090.00 [2] [ ] [27] SURFACE WATER FT [ ] [02] TANK MATERIAL Polyethylene [ ] [281 DITCHES FT [ ] [031 OUTLET DEVICE [ ] [29] PRIVATE WELLS 92 FT [ ] [04] MULTI -CHAMBERED [LZJ N ] [ ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER Polylok PL-68 [ ] [311 IRRIGATION WELLS 85 FT [ ] 106] LEGEND 1. 70-143-11DC3 2. [ ] [32] POTABLE WATER . 10 FT [ ] [07] WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 8 FT . [ ] [08] LEVEL [ ] [34] PROPERTY LINES 25 FT [ ] [09) DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [11 679 [21 SQFT [ ] [36] DRAINFIELD COVER [ ) 111] DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ] 1121 NUMBER OF DRAINLINES 1. 6.00 2. [ ] [381 SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [391 STABILIZATION 06/11/2018 [ ] [14] DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16]' ELEVATION [ ABOVE / BELOW ]BM 0.00 [ ] [40] UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] 1181 DOSING PUMPS [ ] [421 ALARMS [ ] [19] AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] 121) AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN [ ] [46] FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] [22] FILL AMOUNT L ] [47) CONTRACTOR MICHAEL W STUHR (ASHTO [ ] [231 FILL TEXTURE [ ] [ae] OTHER INFILTRATOR Qulck4 EQ36 (single c [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [49] TANK PUMPED [ ] [26) REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. I APPROVED / St. Lucie CHD CONSTRUCTION DISAPPROVED ] Env{)roymental Specialist 113gp�p May (Florida Department of Health FINAL SYSTEM [ APPROVED / DISAPPROVED ]: St. Lucie CHD Env ronmental Specialist II Bri J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP1293320 EID1767365 DATE: 01/31/2018 DATE: 06/14/2018 Page 2 of 3 , l APPLICATION #:AP1293320 STATE OF FLORIDA PERMIT #:56-SF-1767365 DEPARTMENT OF HEALTH DOCUMENT # : F 11191074 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:O6/02/2017 FEE PAID .515.00 RECEIPT #:56-PID-3257336 Violation Number Comment Comments The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 400 gpd. Original permit and soil evaluation voided and changed to a bed configuration. New ST and 6x10 DF installed. No violations observed. System ok to cover, contractor notified onsite. Final required for mound system and final site grading. Well inspected at construction inspection. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1293320 EID1767365