HomeMy WebLinkAboutINSTALLATION OF A ROOF TOP SOLAR POOL HEATER4 , TOP HEADER RUBBER COUPLING DISTANCE DECREASES FOR COLLECTOR COUPLING 4 UPPER HOLD DOWN CLAMP ARRAYS ENCROACHING IN PRESSURE 'x8', 10' OR 12' HOSE CONNECTOR MIN.) ZONE 2 AND/OR 3 SOLAR PANELS (SEE DETAIL A) (2 PER PANEL COLLECTOR HEADER 2.00" I.D. NOT > 48 CTC, NOT < 16" CTC (2) NO. 14 x 2" MIN SS HEX 1-� - — -ON SHER HEAD OR SHEET J SOLAR PANEL (TYP.) ATTACHMENT HARDWARE L BOTTOM HEADER (SEE DETAIL B) PANELS SCALE= N.T.S. f rG , %95 ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COO ,LANCE REVIEWED BY DATE D 6 I3654S Atmo% MIT MUST OR KrAPT ON JOB OR NO INAPP-dIrldN WILL 9F- MADE MOUNT A - (2) NO.14 x 2" MIN SS HEX WASHER HEAD OR SHEET METAL SCREW PER ANCHOR LOCATION ETAL SCREW PER MOUNT - " LOCATION INTO PLYWOOD HEATHING OR ONE SCREW ITH FULL EMBEDMENT IN FTER OR TRUSS 1" DIA SS FENDER WASHER PER SCREW _ ml'' v OEM PVC ANCHOR BUTTON OR 16 GA. 7/8" X 1/2" SS ANGLE (1 1/8" NO.14 x 3" MIN SS HEX LONG) SLOTTED LEG FOR WASHER HEAD OR SHEET STRAP INSTALLATION METAL SCREW PER (TYP.) 50" CTC MAX. ANCHOR LOCATION 1/2" PLASTIC COATED 316 STAINLESS STELL STRAPPING .048" THICK, 670 LB -BREAK STRENGTH —� TRUSSES OR COLLECTOR TUBES EXISTING ROOFING CINI z ` (n W V °o U ?w b a. W Z N N N~ o 14. z a W o 0w < � O I O 1 U O N MINIMUM 1/2" O.S.B. OR 1/2" CDX PLYWOOD SHEATHING (DESIGN OF SHEATHING BY OTHERS) ROOFING (EXISTING) I \ A MINIMUM 1/2" O.S.B. OR 1/2" CDX PLYWOOD SHEATHING (DESIGN OF SHEATHING BY OTHERS) ANCHORING SCREWS SHALL HAVE TRUSS OR 1/2" PLASTIC COATED 316 DETAIL .B MAXE50" CTCIMAX. ALONG STRAPRAFTER STAINLESS STELL STRAPPING N0S4 x 3" MIN SS HEX .048" THICK, 670 LB BREAK WASHER HEAD OR SHEET STRENGTH METAL SCREW PER ANGLE OR PVC BUTTON ANCHOR LOCATION TRUSSES OR 1. THE STRUCTURAL SYSTEMS DEPICTED HEREIN THESE DRAWINGS WERE DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 5TH EDITION (2014) AND ASCE 7 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES (LATEST EDITION). 2. WIND SPEED IS 170 MPH ULTIMATE VELOCITY (132 MPH NOMINAL WIND SPEED) RISK CATEGORY IFSTRUCTURES. 3. WIND EXPOSURE CATEGORY= C & D (SEE NOTE #7) 4. ROOF ANGLE: 0" TO 45" 5. HEIGHT OF STRUCTURE < 60 FT. 6. MEAN ROOF HEIGHT (MRH): UP TO 30' 7. SS STRAP SPACING FOR WIND EXPOSURE C IS 36" OC FOR ZONE 1, 24" OC FOR ZONE 2 , 16" OC FOR ZONE 3 FOR MPH UP TO 15'. SS STRAP SPACING FOR WIND EXPOSURE D IS 30" OC FOR ZONE 1, 20" OC FOR ZONE 2, 12" OC FOR ZONE 3 FOR MPH UP TO 15'. FOR EACH 5 FT. INCREASE IN MPH UP TO 30' - DECREASE STRAP SPACING BY 1". 8. NO USE IN PRESSURE ZONE 3 IN HVHZ V VA "" DETAIL C SCALE= N.T.S. ROOFING (EXISTING) MINIMUM 1/2" O.S.B. OR 1/2" CDX PLYWOOD SHEATHING (DESIGN OF SHEATHING BY OTHERS) ANCHORING SCREWS SHALL HAVE EMBEDMENT IN TRUSS OR RAFTER MAX. 50" CTC MAX. ALONG STRAP s P 1sI 1f; 9£ f t€s^ $�1; �'e`E 9 y NI! z W rn ui d > Ma 2uo^D �m QUN fn v� _ . . Z W N d o V� a `x%%ktIIisllO ` LIiUE INK ItE?j IIGI S NEAL�j-F A FLORIDAD CENSED ®W�ER. EVE P YYippULLED REQUIRES A ® Q 9 RIGINAL PAe CDPY OF THIS PLAN. UJ Z: N BE USED FQ L1�IS ON FILE. Q = V V, O J _p:J o' �:z = O ter:• 2 /t �•�� Z CL J ` f� T fjj t�I1Tfi,o FL# 42082 N z NOTE: CONTRACTOR TO USE OEM ATTACHMENT PARTS ONLY !t INSTALL A 3/8" S.S. MACHINE SCREW THROUGH TUBE INTO TOP OF S-5 CLAMP 1 / 1" SQ. X 1/8" ALUM. TUBE (6061-T6) "S-5" ALUM. CLAMP -Od 2" 1 1/2" (6061-T6) INSTALL A MIN. OF (2) 3/8" BULLET NOSE STAINLESS STEEL SET SCREWS TO STANDING STANDING SEAM METAL ROOF CONNECTION ASSEMBLY SCALE- N.T.S. NOTE: FOR TIEDOWN ANCHORAGE OF SOLAR PANELS TO METAL ROOF, STRAPPING ASSEMBLIES DETAILED ON PAGE S-1 SHALL BE ANCHORED TO ASSEMBLY DETAILED ABOVE FOR CONNECTION TO STANDING SEAM METAL ROOFS. SCREWS SHALL BE #14 X 1" MIN. SS HEX WASHER HEAD OR SS SELF TAPPING SHEET MEAL SCREWS, ASSEMBLY ANCHORAGE: INSTALL 1" SO, X 1/8" SQUARE ALUM. TUBING TRACKS FOR SOLAR PANEL ANCHORAGE OVER'"S-5" ALUMINUM CLAMP (6061-T6 ALLOY) AS MANUFACTURED BY "DYNAMIC FASTENER") OVER STANDING SEAM OF. ROOF PANELS. _CLAMP SPACING TO MATCH STRAP SPACING (48" CTC FROM PANEL EDGE TO PANEL EDGE, AND AS SPECIFIED ON PAGE S-1 FOR MAX. SPACING PADAI I Cl Tn DIM AC DAMO LEGEND O1 VACUUM RELIEF (1 MIN. W/ OPTIONAL LOCATION) 2N THERMOMETER 3r SENSOR 04 BALL VALVE (OPTIONAL) OS CHECK VALVE 06 3-WAY VALVE 7w WATER SENSOR 08 FILTER 09 PUMP lOr1 AUXILLARY HEATER 11■ AUTOMATIC CONTROL 1 OPTIONAL COMPONENTS OM POOL GENERAL..NOTE,IN COMPONENTS ARE OPTIONAL TYP. PLUMBINQ SCHEMATIC SCME N.T.S. NOTES: 1. PLUMBING SHALL BE INSTALLED AS PER DETAIL AND ALL REQUIREMENTS OF THE FLORIDA BUILDING CODE 5TH EDITION (2014) PLUMBING. SPECIAL CARE SHALL BE TAKEN REGARDING PIPE SUPPORT, PER FPC TABLE 308.5. THE ABS VALUE OF 4 FT. SHALL BE TAKEN AS THE MAXIMUM FOR HORIZONTAL AND 10 FT. FOR VERTICAL SOLAR PIPING. PER 2010 FLORIDA MECHANICAL CODE, CONTRACTOR SHALL INSTALL MANUAL DRAIN DOWN VALVES AND INSTRUCT OWNER IN DRAINING AND RE -STARTING THIS SOLAR POOL_ HEATING SYSTEM. OWNER SHALL BE INFORMED THAT FREEZE PROTECTION IS IP TO OWNER. IF SOLAR POOL HEATER FREEZES, IT IS THE OWNER'S SOLE RESONSIBILITY. FREEZE DAMAGE RESULTS FROM AN ERROR IN OPERATION. COLLECTORS SHOULD ALWAYS BE DRAINED BY OWNER OR OWNER'S' REPRESENTATIVE IN ADVANCE OF NEAR FREEZING WEATHER. _NOTES: 1. CONTRACTOR IS ENCOURAGED TO INSTALL SYSTEM IN PRESSURE ZONE 1. IF PART OF SYSTEM MUST ENCROACH INTO PRESSURE ZONE 2 OR 3, ANCHORING SHALL BE ADJUSTED AS PER SPECIFICATIONS HEREIN. CONTRACTOR SHALL ATTACH COLLECTOR ARRAY WITH OEM HARDWARE AND STRAPPING. CONTRACTOR MUST BE CAREFUL TO "CENTER" ANCHORS SO SCREWS ARE INSTALLED INTO THE CENTER OF THE TRUSS TOP CHORD OR RAFTER BELOW. AN APPROVED ALTERNATIVE WOULD BE CONTRACTOR INSTALLED NOMINAL 2"X4" SOUTHERN PINE #2 BLOCKING BETWEEN TRUSSES OR RAFTERS AT SCREW LOCATION, CENTERED ON SCREW. BLOCKING SHALL BE CONNECTED TO TRUSS OR RAFTER WITH SIMPSON A34 OR A23 ON EACH FACE OF BLOCKING (2 CONNECTORS PER CONNECTION TO TRUSS OR RAFTER). 2. CONTRACTOR SHALL ADHERE TO REQUIREMENT OF FBC CHAPTER 15 (ROOFING) AND BEST PRACTICES OF NRCA ROOFING & WATERPROOFING MANUAL TO ENSURE THE SOLAR INSTALLATION DOES NOT CAUSE ROOF LEAKS AT INITIAL INSTALLATION OR AS THE SYSTEM "AGES". 3. AS LONG AS CONNECTOR SPACING AND NUMBERS 'ARE NOT REDUCED THE CONTRACTOR MAY USE A SUBSTRATE OR ALUMINUM MOUNTING FRAME, "SANDWICHED" BETWEEN THE COLLECTOR AND ROOF ON FLUSH MOUNT INSTALLATIONS ONLY. 4. OEM STRONGLY RECOMMENDS AGAINST CLAMPS ON THE BOTTOM HEADER. 5. SOLAR UNITS INSTALLED PER THIS PLAN SHALL NOT FORM PART OF THE BUILDING ENVELOPE (I.E. WINDOW, DOOR). SOLAR' UNITS SHALL BE MOUNTED ABOVE ROOF SURFACE LIKE A A/C CONDENSER. THEREFORE NOT REQUIRING A PRESSURE RATING (I.E. WINDOWS, DOORS). SOLAR UNITS SHALL BE MOUNTED VERY CLOSE TO THE ROOF SURFACE, TO PROVIDE PRESSURE EQUALIZATION BETWEEN THE ROOF SURFACE AND THE BACK OF THE SOLAR UNITS. THIS RESULTS IN NO SIGNIFICANT CHANGES IN THE LOADS ON THE ROOF FRAMING FOR A PARALLEL MOUNT AND a: MODEST CHANGES IF TILT UP. HOWEVER THE INTERNAL AND EXTERNAL, COMPONENTS OF WIND PRESSURE DECOUPLE, E.G. THE ROOF RESISTS THE INTERNAL WIND PRESSURES AND THE SOLAR UNITS RESIST THE EXTERNAL h: WIND PRESSURES. THE EXTERNAL WIND FORCES ARE THEN TRANSFERRED TO THE ROOF FRAMING THROUGH THE SOLAR ATTACHMENT 0: HARDWARE. 5. SOLAR POOL HEATING COLLECTORS ARE REQUIRED TO BE TESTED, CERTIFIED AND LISTED BY THE FLORIDA SOLAR ENERGY CENTER. CONTRACTOR SHALL PROVIDE DOCUMENTATION TO OWNER OF THEIR LISTING AND RATINGS. 1" DIA SS FENDER WASHER PROVIDE 1/4" STAINLESS STEEL TAPCON SCREWS OF ADEQUATE LENGTH TO SECURE BRACKET TO CEMENT TILE DRILL HOLE THRU CONC. TILE'ONLY (NOT INTO ROOF MEMBRANE) AND INSTALL TAPCON SO AS NOT TO BREAK TILES. Flat oot Gable Roof (0 5 71 Hip Roof (704 A 5 271) Gable Roof (70< 0 S 45"1 Interior Zones ® End Zones Comer Zones fl001f•ZOM "WOPJ •2➢n0d R.I.- Z.. 2"A. Z., 6 Pooh. Z_3 PRESSURE ZONE NOTES PRESSURE ZONE NOTES 10 PERCENT OF THE LEAST HORIZONTAL DIMENSION OR .4h, WHICHEVER IS LESS, BUT NOT LESS THAN EITHER 47. OF LEAST HORIZONTAL DIMENSION OR-,3 FT. MEAN ROOF HEIGHT, IN FEET, EXCEPT THAT EAVE HEIGHT SHALL BE USED FOR ROOF ANGLES < THAN 10 DEGREES. ANGLE OF PLANE OF ROOF FROM HORIZONTAL, IN DEGREES. THE STRUCTURAL SYSTEMS DEPICTED HEREIN THESE DRAWINGS WERE DESIGNED' IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 5TH EDITION (2014) RESIDENTIAL AND ASCE 7 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES (LATEST EDITION). SEE PAGE 1 FOR DESIGN WIND SPEED, STRUCTURE RISK CATEGORY, WIND EXPOSURE CATEGORY, ALLOWABLE ROOF ANGLES, MAX. HEIGHT OF STRUCTURE AND MEAN ROOF HEIGHT, AND STRAPING REQUIREMENTS. COLLECTOR HEADER 2.00" I.D. 5/32" WALL THICKNESS NOTE: -`"— APPL ADHESIVE TO THE INTERFACE OF THE SOLAR WORLD MOUNTING BRACKET AND PVC BUTTON ANCHORS BEING ATTACHED TO THE CONCRETE FLAT TILE OR BARREL TILE. CONTRACTOR SHALL ALSO APPLY ANCHORING EPDXY TO TAP CON SHAFT PRIOR TO INSTALLING TAP CON. TAP CON TO BE INSTALLED PRIOR TO EPDXY SETTING. A 3"xl"xl/8" ALUMINUM (ALLOY: 6061-T6) ANGLE MAY BE USED TO MOUNT PANELS TO TILE AS A CONTRACTORS OPTION. APPROVED ANCHORING EPDXIES ARE CHEMLINK "M-1 ", SUREBOND "SB-190" OR APPROVED EQUAL. INTERMEDIATE BUTTON ANCHORS TO BE PROVIDED FOR SS STRAPPING � • T AS DETAILED ON PAGE S-1. SPACING OF BUTTON ANCHORS ARE 48" OC ALONG THE SS STRAPING. SPACING OF STRAPING IS 27" OC (EXP. C) & 24" OC (EXP. D) FOR PRESSURE ZONE 1 AND 16" OC (EXP. C) & 12" OC (EXP. D) j FOR PRESSURE ZONE #2. PANELS ON TILE SHALL NOT BE INSTALLED IN PRESSURE ZONE 3. ADJUST STRAPPING SPACING FOR MEAN ROOF HEIGHT OF STRUCTURE FROM 15 FT. TO 30 FT. AS SPECIFIED ON PG. S-1. BUTTON ANCHORS TO BE INSTALLED IN CENTER AND/OR CROWN OF TILE. STRAP BRACKET TILE ROOF SCALE= N.T.S. COLLECTOR TUBES 0.220 I.D. WITH 0.030 WALL �- CONC. BARREUFLAT TILE 0 J �`,`�( S �� �yy�ilNG W �ITHTHE BLUE'• ¢S GNATUR N Q A SAL OF A �,MA yii�OREALE U. ;NSN EER EV P TM- ULLED 51RE4 D O,�L P F�COPY OF e _1 O O PLAT. MAY -NO U A>LANS ON Z O '•� 0 m IL O 1 L Q TODD N. SMITH, PE FL# 42082