Loading...
HomeMy WebLinkAboutCERTIFICATE FOR DESIGN LOAD COMPLIANCEI aq S4 L 7Jl c F; Planning & Development Services Department Building & Code Regulations Division h -- 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Meadowood Project Address: 9504 Poincianna Ct Permit #: Occupancy Type: R-3 Construction Type: VB INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2014 Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 170 mph 132 ASD LRFD End Zone Width: 6 ft 5. Mean Roof Height 15'-0" ft Roof Pitch: 5 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: -35.0 Zone 2: -61 Zone 3: -90.2 Zone 4: -41.5 Zone 5: -51.3 Garage: -35.2 7. Design Loads:. Floor: 40 PSF Roof/Dead: 25 PSF Roof/Live: 20 Balcony: 60 PSF Dock: NIA PSF Deck: 60 PSF Stairs: NSA PSF Fence: NSA PSF Railings: 50 PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: ' 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie Coun y. I certify that structural elements depicted on these plans provide adequate resistance to the design � •,.N . Stephen R. Walsh P.E. #33915 �iQ•. '� • :�� Print Name Cert # & Co. Cert Auth. E Y.j33915 Walsh Engineering, Inc. "¢' 3200 N. Federal Highway, Suite 226 Boca Ra31Xure, Date,�niR, aOPY C '•. Q ��,•' `�• `�� Company Name &Address •�.q,,�,�� o It