Loading...
HomeMy WebLinkAboutSCREEN ROOM - SOLID ALUMINUM ROOFr- m m r- -_i O 1/4" LAG W/ 1" DIA. WASHER ® 8" O.C. T-3 W/#10 SMS B" C.C. BOTH SIDES 3" INSUL ALUM. WALL 10'-7" EXIST. HOUSE 1X2 6LB N O N CNfl 6LB 1X2 24" 6'-8" 16" 10'-0" T-3 W/#10 SMs 8" C.C. BOTH SIDES CONT. 2X2X1/8" ANGLE W/#14 TEK SCREWS ® 12" C.C. EA. FACE (4)—#14 TEK SCREWS PER- GUTTER BRACE & ® 12" C.C. MAX ELSEWHERE SUPER GUTTER 4" INSUL. ALUM. ROOF r - 6" LONG GUTTER "Z" BRACE @ 24" C.C. 2" MIN. FASCIA* ALL EXISTING FASCIA TO BE A MIN. OF 2' THICK AND MUST BE SECURED TO EACH TRUSS OR RAFTER END W/ A MINIMUM OF ONE 1/4' X 3 1/2' LAG SCREW PER TRUSS OR RAFTER END. NOTE: 1' FASCIA MAY BE BUILT UP BY LAGGING NEW 1' MEM. TO OLD 112 - 1/4'x3 1 2' LAGSJJ'((��USS OR RAFTER. 2' SUB -FASCIA BEHIND 1 FASCIA IS ALS� ACCEPI"ABLF_ SECTION A -A MAY 3 0 201 ATTACH TO EXIST. HOUSE WALL EXIST. HOUSE EXIST. 12" A SUPER NEW 4"X.024"X1LB EPS GUTTER PANELS (SPANS BY DO KIM & ASSOC., LLC FLORIDA PRODUCT APPROVAL # FL-7561) i= ID I I I I •------------------ --------------- 12" O.H.-------� - 27'-0" 1:1 WA 21 c m CO r n I � �o x Mo 6'-0" 1 6'-0" 27'-0" FRONT ELEVATION ' e c CO I o O O XIS. HOUSE 5LB O N I (O >z CNI I J LB LLQL a 0 3'X6'-8" �' o E— DOOR I = 1 X2 0 6" 6'—B" 24" Cr I4EW ALUM. KICK PLATE (TYP) NEW CONT. 16"X12" STRIP. FTG. W/ 2—#5 REBAR ' (TYP.) (o File copy o Q CONCEALED FASTENERS OR ATTACHMENTS , ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD m o+ a1 THESE PLANS AND ALL PROPOSED Wi7c:: W ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT `,'.,AAY BE NECESSARY IN ORDER TO CO'u)PL'��p � I�: .kICA9L!g-.CODES. Si. J CIS. C OLr:;TY LRUIT DE'4G D-MSION , ? VIENVE-i FOR ,-,1PL1AN%-_E its..3�.6iry � PLAN, S AND PERrv,_ IT MUST BE KEPT OIL JOB OR NO P,vSPECTION IVVML BE fi2��E. NOTE: DOOR LOCATION IS OPTIONAL CONTRACTOR MAY ADJUST IN FIELD PER HOMEOWNER REQUEST NOTE: THIS JOB WAS DESIGNED BASED ON 6061-T6 ALUMINUM ALLOY AND 1BX14 SCREEN MESH. INDIAN RIVER COUNTY DESIGN CERTIFICATION CODE EDITION: FBC 2014 EDITION OCCUPANCY: SINGLE FAMILY DWELLING — SCREEN ROOM BUILDING DESIGNED AS: OPEN STRUCTURE BUILDING HEIGHT < 60 FEET MEAN ROOF HEIGHT, 10'-0" RISK CATEGORY: I[ BASIC WIND VELOCITY PRESSURES: WIND SPEED: 160 MPH (3 sEcom GusT) BASIC WIND VELOCITY PRESSURES: 19.0 PSF WALLS 30 PSF ROOF ROOF DEAD LOAD (ACM DEAD L0+1D usm To REsw uPUFr Ro=oNs): 2 PSF SOIL BEARING CAPACITY: WELL COMPACTED REVIEWED FOR SHEAR WALL REQUIREMENTS: YES IMPACT PROTECTION SPECIFIED: NO Dig AraAIM� FDWMAIMN WPURN.,ANN SNOMii ON THIS PUN S EASEO ON DATA PWMM Sf TK- CONDUM-103/Ot BIT. RM FDUH TOM SPECMED ARE 7HE R'm+ Ulaw 70 REMT PLL SUP EZ"TOSFD I.M. AND DEAD LOADS FWJ 7ME PROPOM STUCaW_ } O U W a U wof w N O X p w W C) Z_ N 3: In F- Q W 2 � J O rL F- 2 O O LL Z O C/) W Z Q U) Q .J 0m _. Lu Z Cn 0 w � =w i- 0 v 0 I O O 00 m � m O O Z O LLI Z Y FF I]J J U W O Q U 2 2 LL_ O O Ld Q O o J O p 0 o w w gJ V) 00 W CD L` H 0 ofof xz U O IZ d U) a- � 01-) z U U) H 10 �. U o ccoo N CA � 7� Z Y/ W rn W z W �� O W z a� x Z z W O Li s CC _ WQ U H W Co U) rro Cd •L —I 10 I v7 LL_ 3 c U z �j (D = M � r- CIL #2 0 12" C.C./PANEL T&B EXIST. DRIP CAP HOUSE INS. ROOF AL FLASHING c 2x3 i CONC. WALL �� ���PnoNAL TRUSS #8 ® 8" C.C. 'LASHING r ` EXIST. '- PAIVO- BEAM MOBILE 'F• #2 0 12" C.C. HOME /PANEL T&B 7 TG EA EXIST TRUSS 2-1/4"X2-1/4" LON THRU BOLTS PANEL oM CHANNEL AND 0 12 2' MIN. FASCIA TAPCON ANCHOR 2"X2"X1/8" CLIP ANGLE :: 49 ;;:!1QA$HERS & NUTS O.C. MAX. TO FASCIA THRU CUP INTO EXTG. EA. SIDE %2 — #4 OR 1/4" AIR GAP #3 ® 12' D.C. TO CONC. WALL �A. C O BEp ;'''. ' • CONG. 3— 2 UP T BM. :: —1 #7-1s" O.C. NOTE: FASCIA MAY BE BUILT UP BY LAGGING NEW 1" MEA1. TO OLD/ TWO EA. CUP. 4/BM FOR7 BEAMS OR TO 2 X 4 STUD H-2 OR H-3 z-1/4' x 3-1/2' LAGS/TRuss OR RAFTER. �OR 9" BEAMS OR GREATER GREATER, USE 3 - #4 :;:: ':::: 12" SUB -FASCIA BEHIND 1" FASCIA IS ALSO ACCEPTABLE. USE (3) TAPCONS. OR (4) — #2• (MOBLL' ,";k101+1t } ,: '' : PANEL TO WALL CONN. FASCIA CONN. - BM TO HOUSE CONN. COL:ttlaNG:: Z4. 1X2i2; 'air .`1 u: N N - CAULK Ch; PANEL #5 (EA*4A SIDE) W/ 2 #4 WATER- °Z \ \ z ..00 TO BM. MPROOFING 61-+ w J > ANCHOR WINDOW w w o i:• o > FL'G. OR 302 W/ #1A a ¢ ¢ LEI : �.:. •: J Jw WTIONAL N of w `r :' :: N U 40 = ; w p 16" O.C. MAX: 4 N 0 Tn N Mtn „s (n SIDES TO U) FROM ANY GQ hIEi m a IL =w ; 0 OIL %:I m Vt ::; : N MI. w c`}v o y FOR 7" BEAMS OR GREATER CORNER COL. USE (3) - #4 & (3) - #7 BM. CONN. AT FASCIA BEAM SPAN SEE SCHEDULE :. VARIES MAX. COL HGT. PER TABLE ROOF PLAN'.: ' A BEARING WALL SEE COL. SCHEDULE (SH 1. B2") T: o ~ ELEVATION ' A`'''' •'i; 0 n, uj SCREEN ;; RIN:{tJglrL 8'-0:`•:b1AX'C•:� � . $CtiEEt1`•:R' :°t?A]i ' '•• ,COL:!: ;CHAIR RAIL PER SCHED. COI COL :::::::': :: :::• ,L. KICK PL. OPT. JSE 202 TOP ATT. KP 1/1-#2 @ 8" O.C. FASTENING SCHED'bf 6 `�-" ELEVATION 1 14 TEK SCF EW/HEX HEAD SUN Roots 2 - ,10 S.M.S./ HEX HD. 3- 1 /4" X 2 1 /4" TAPCON ANCHOR 6OYPS,) 4 - 1/4" BOLTS/WASHER/NUT 5 - CLIP ANGLE,.125" MIN. THICKNESS 202— E - #12X1" LG. S.M.S./HEX HD. 2 SCREWS 7 - 1 4" X 3" LAG 5 SCREWS MIN.— 8 - 1 /4" LAG*, WITH 1" WASHER EACH SIDE) 9 - #10 X 1 1/2" S.M.S./HEX HD. 12 - CLIP ANGLE, 3/32" MIN.THICKNESS *LAG BOLT LENGTH TO BE 1" LONGER COL B- J NER W1 o 12• C.C. BOT. 3/PANEL —48 ® 8" CARRY BEAM PER SCHEDUL OPTIONAL 1X; ♦ 2'X2"X1/8" X 2" CLIP ANGLE W/3 EA. FACE 202 4LB" COL SEE ANCHORING SPECSFOR HEEL RC-) 1X2 SECTION B—B (SCREEN ROOM) * SEE TABLES OR SITE SPECIFIC CONN. TO BE CONT. I 1X2 (SNAP WAY BE usm) TOP TO BOTTOM OF PANEL OF 20 ALL JOINTS #8 0 8- C.C. PAN PANEL BOTTOM T-2 OR T-3 BOLTS THRU- BEAM PER SCHEDULE •.'iN� OR SITE SPECIFIC :fq WINDOW FRAME 3X34 , COL. T-2"O fi �TIi7►V':>4—A . ::'SECTION C—C 'AR•Jt{T)1JN ROOM) :S FY)f2::'aLiiJi(itt;;BEAtJ(i'A1JD COLUMN SIZES. NC}!OR 1XZ'V.*- 4:;:; ::;:r;.;:. CARRY BEAM PER SCHEDULE Ti�•v't '0i1;': ANGLE W/ /8"7(4LO'TAPCON TO & (4)-#6 TO COL (M) 1X2 OPTIONAL CARRY BEAM 202 202 THAN ALUMINUM PANEL THICKNESS CARRY BM. TO ALUM. COL. CONN. DETAIL INSULATED ALUM. PANEL DETAIL SHEET: COLUMN—1 6,4 L2—#2 (TIP•) INTERMEDIATE COL. FOR SCREEN ROOM F.B.C. 2014 EDITION & ASCE 7.10 AL TK. ALLOY 3003 - H1 Ar3E �'d12�'' OR EQUAL un WINDOW 0100. 0 FRAME BY' :: Cbh) f)JVU411S': °o:' o 0 0 BULKING' ° o iv iq <t io io WINDOW :;,( '' :p'o °0 0 0 MA,N.:411T. 0 0 0 0 EL MAY PLYWOOD G ALL 2" #2 ® B" O.C. EA. SIDE FOR COLUMNS 5" DEEP OR GREATER INSTALL ADDITIONAL 2"X2"X2-X7/8" ANGLE EA. SIDE OF INSIDE OF COL W/3-#6TOCI & 1 - 3/8" X 4" LG. EXP BOLT (WEDGE ANCHOR) TO CONC. EA. CLIP 2`X2'X1/8" X 4" LG. ANGLE EA. SIDE OF COLUMN W/ (4)-#14 TEKS TO COCARRLUM 6 & (2)-1/4" THRU-BOLTS To .91 EV AM O.C. / gLiFEM #3 0 18" O.C. P 7`67ALUM. COLUMN ALUM' CARRY BEAM ALT. CARRY BEAM TO COLUMN ifi':�sPd9 FROM TABLE OR FL PRODUCT APPROVAL PITCH IS 74" PER 12", MAX IS 6" IN 12" ROOF PANEL CONNECTION (FRONT ELEVATION) ROOF & WALL PANEL DETAILS PANEL SCHEDULE: ROOF PANELS .PANEL L/80* 12' SPAN OR LESS L/120 L/180* OVER 12' R — 2 11'-6" 12'-0" -- R — 3 12'-0" 13'-69' -- R — 4 -- 16'-2" 13'-10; R — 6 -- 20'-8" 1 177-10' R — 8 -- 24'-4" 1 21'-3" * = FOR USE IN HVHZ AREAS ONLY 2"X2"X2" LONG X 1/8' ANGLE EA. SIDE OF COL W/ 4 6 TO COL & 1 3/B" 4" LG. EXPANSION BOLT (WEDGE ANCHOR) TO CONC. 0 EA. CUP 3" FROM EDG J ;I ;f TO BOLT (MIN COLUMN ANCHORING DETAIL 4 #6 TO COL (TYP) CUP ANGLE COL 1 - 3 8" X 4" LG. EXPANSION BOLT (EDGE ANCHOR) TO CONC. (TYP-) 2 PER COL 0_ ® 18" O.C. 1X2-- m ♦ ELSEWHERE u u ' \--- DELETE 1X2 FOR FRONT ELEVATION OPEN PORT (TYP.) NOTE: ANGLES ARE NOT REQ'D. FOR 202 DOOR JAMB COLS. #8 THRU PANEL, BM. ALL ANGLES SECURING THE COLUMN TO THE CONCRETE TO BE 2"X2"X7/8"X2- 8" C.C. LONG. USE ONE ANCHORS PER CUP - MIN. TWO ANCHORS PER COLUMN IN ALL CASES. 3/8- DIA. BOLTS ARE TO BE EXPANSION TYPE (SEE ANGLE TO CONC. DETAIL) EXPANSION BOLTS TO BE "HILTI KWIK BOLT II" SYSTEM OR EQUAL *3/8" TAPCON MAY BE USED IN LIEU OF 3/8" EXPANSION BOLT SEE GENERAL NOTE 4 FOR ADDMO14AL REQUIREMENTS 2 (1-1/2" LONG) ®11 " C.C. (TYP,) DATE 07/01 / 15 ENGINEERING BUSINESS CA 00009677 2"X2"X1/8" X 2' LONG SCALE N.T.S. NNW TARNOWSKI CLIP EA. FACE LL W/3 - :r2 SHE -manENGINEERING SCREEN ROOM COL. TO BEAM CONN. CIVIL & STRUCTURAL ENGINEERING 7360 N.W. 5th Street Phone (954) 727 - 2027 FL 33317 Fax (954) 727 - 9644 C.T.Plantation, CTARN0I�SKI E. THIS DOCUMENT IS THE PROPERTY OFTARNOWSI4 ENGINEERING, t INC. AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART STRUCTURAL ENGINEER - FLA. LIC. 0050662 WITHOUT WRITTEN CONSENT OF TARNOWSId ENGINEERING, INC. .I ry p ,,.-,040" p 040" r i 040" 0 044" .060 [V IYP. TYP. TYP. ni TYP. ` - 102 1X2 1X3 202 2X3X.060 # OR p LB OR LARGER OR #10 S.M.S. FOR 61-8 OR SMALLER.0 18' C.C. { z O TOP & BOT. x rn e m BEAM TYPE ts t r 4LB .100 .046 5LB .116 .050 +% 6LB 050 xd 7L6 .120 .055-21 L 2" BILE! .224 .072 9LB .224 .072 9LBH 306 .082 4LB.5LB,6L6,7LB 15LB I .389 .092 8LB,9LB,9LBH 10LB LAP BEAM T BOLTFAIN , , VX8_ 1 /2" 1 " x � d io .064" N W 050" w1 1. " 55" '�' io N to 0 1YP. dN tri 55" y «i rO55- 0.5 :'':'':' • TV 00 2.0" 1 A 3.0 ;.;:2. :.::: 3.0 C' ::1'�t2 ;::;:• C 2X2 2X3X.050 GUTTER -GUTT R FASCIA DUiR*-:-'JAMB C T''X3: C 2X3 2X4X.050 2X5X.050 FOR COLUMNS 5" DEED:;;:;::';;:::; 0 070 M 3.0" 3X3X.070 303 SEE COLUMN ANCHORING DETAIL 1X2 OR iX3 PAVERS OR TILES ,4/' OPTIONAL 0 � COMPiii iiii TO BOLLT STRIP FTG. DETAIL W/ PAVER OR TILE * 12"X 8" FTG. IS MINIMUM FOOTING SIZE. REFER TO SITE SPECIFIC PLANS, AND STRIP FTG. SCHED..FOR ANY. ADDITIONAL REQUIREMENTS. MIN. FOOTING SIZES SHOWN APPLY TO NEW FOOTING'S ONLY. FOR EXIST. FOOTING'S SEE SITE SPECIFIC PLAN. FINISH GRADE SODDED REQC FOR EROSION PROTECTION / 2" MIN. COVER * NOTE: SITE SPECIFIC ENGINEERING I WHEN THIS MEASUREMENT IS SOLID ALUMINUM ROOM. (EXI ENGINEERING IS NOT'.'"A 4 'IRI EXISTING HOUSE;_13(3' NOTE APPU WIDE CUP ANGLE tEXPOSED C, 0 5.094" �III(`��IIIIII t to N p • LV Z-GUTTER BRACE PAVJ RS':•.OR, TILES SLiApB i FfG�WO/W1Wiy OR TILE JEU OF 6X6 - 10/10 W.W.M. COLUMN ANCHORING D; lJcf::?:, ::•;;; 3" FROM EDGE SEE COLUMN ANCHORING DETAIL TO BOLT (MIN.): ;i:'•;.:::::r :' CO 3' FROM DG TO BOLT I MINE} XISTv:q�'..NOMINAL ONC ::SkA$; , ? 1 ' .:..... ....... ..... 4' CONIC. SLAB icti{�u';FOR'seE�iADts:':•:• 8 w 6X6 - 10/10 W.W.M. :S$•; td:, 3'-0."•,rlkN�:';EOi?;:ALL W% 8"XS" FTG. W/ 1-#5 FOf�:;srri2$FA1';iAtls UNDER FTG. & SLAB DETAIL NOTE: FIBERMESH MAY BE USED IN LIEU OF 6X6 - 10/10 W.W.M. FOR 65OMNS 5" DEEP OR GREATER INSTALL COL 2"X3'X1/8' X 2' LG. ADDITONAL 2"X2"X2"X1/8' ANGLE EA. SIDE 2" 2" MIN. ANGLE FA SIDE OF OF INSIDE OF COL W/ (3)- #6 TO COL COL W/ (4)- #6 TO & (1)- 3/8" X 2 1/2" LG. TAPCON COL & (2)- 3/8" X '•::TO CONC. O EA. CLIP ® ® 3 1/2" LG. TAPCON TO CONC. 0 EACH CUP. #6 TO COL (TYP) in z :. ;i:,::•.: COL (2)- 3/8" X 3 1/2' LG. TAPCON C4 TO CONIC (TYP.) 4 PER COL. O O' ® 0 3 018" .C. ELSEWHERE xr,1 ? C•. FTG. 3' FROM EDGE --/',- 3 "2 BE DELETE 1X2/1X3 FOR MIN FA MIN. OPEN PORT tr- ) ELEVATION COLUMN ANCHORING DETAIL NOTE: ANGLES ARE NOT REVD. FOR 202 DOOR JAMB COLUMNS. n4' LG. EXPANSION BOLT OF SAME DIAMETER MAY BE USED IN LIEU OF TAPCON TAPCONS ARE TO BE SIMPSON "TM" OR EQUAL SEE GENERAL NOTES 2 & 4 FOR ADDITIONAL REQUIREMENTS GENERAL DETAIL SHEET: 4.0 33.0" d90" o 0 125" 050" TYP. N pd TYP. 2X2 2.0 2,0 3X3 � 2X44 4X4 2X5 4.67" Fle Copy M W N 064" tri 78" :. ':;Ci64: :';':•.'• 'A60" n TYP. 125" G II 5.25" SUPER (-,1V- -.F-R F., . T-3;:; ' } 2'. H-3 L 2X2 OR GREATER INSTALL •: ••: ••••: •: •: ••••GQ1:-:.: :'•;.;�;:•; :•;•:' ADDITIONAL 2"X2"X2"X1I�Ei,"'::::•':':::;:'•:;:'::::'•;':•. ANGLE EA. SIDE OF INSIDE ::•:::•: :':: 2^ 2^""' 2"X2"X1/8" X 2" LG. MIN. 3X3 OR 4X4 OF COL. W o 4 :;•': 6, TO COC'.•.::;:,.,:::: ANGLE EA. SIDE OF COL / (�y W/ (4)- 6 TO COL & ALUM. COL & (1)- 3/?.:;'7S•;:::.1 f'L" LG. .:; 1- 1 2 X 3 1 2' LG. r: C' P a:• ::3•: s:: TO CONIC: . • . �ApCON TO CONIC. ;�.•..:•• ., :::: • �:� •�,.- ., ,ram'. ;'�".: ;i :�'t: • r:. >ir „ ';:.... j k,. I Of CONC.:: , OU F N .0 BOLT (MIN.) COLUMN ANCHORING DETAIL (4)- #6 TO COL (TYP) CLIP ANGLE COL�TAPCOPTO OONC./2LG. TYP.) 2 PER COL 3 O 18" O.C. 1X2 1X3 LSEWHERE FTC. DELETE 1X2/1X3 FOR FRONT ELEVATION OPEN PORT OYP.) NOTE: ANGLES ARE NOT REQ'D. FOR 202 DOOR JAMB COLS. ALL ANGLES SECURING THE COLUMN TO THE CONCRETE TO BE A MIN. 2"X2"X1/B"X2" LONG. 1/2" DIA. BOLTS ARE TO BE EXPANSION TYPE. (SEE ANGLE TO CONC. DETAIL):; EXPANSION BOLTS TO BE 'HILT] KWIK BOLT 11" SYSTEM OR EQUAL *4" LG. EXPANSION BOLT OF SAME DIAMETER MAY BE USED IN LIEU OF TAPCON TAPCONS ARE TO BE SIMPSON "TITEN" OR EQUAL SEE GENERAL NOTES 2 & 4 FOR ADDITIONAL REQUIREMENTS THIS STRUCTURE HAS BEEN DESIGNED & TESTED IN F.B.0 2014 EDITION. THE MIN, MECH. PROPERTIES OF THE ALUM. CONST. MANUAL THIS STRUCTURE ALSO C OF THE ASCE 7-10 SCREEN WALL & SCREEN ROOF.LnAD: ALUM. PAN & INS. PANEL STR. "-,-k 1. ALL PRIMARY MEMBERS WILL BE CONNEC1E6}49":f FASTENERS. 2. ANCHORS SHALL BE PLACED GRW-E-A,• THAN ALL CONIC. FASTENERS MUST $E.RMhti;:''A MIN. 0 LENGTHS SPECIFIED IN INDIV},btJR�:';tiA1LS;.:;:;'• •. 3. FASTENERS FOR ALUM. Sk(EEl � '.-:SIiALL XCE€I 4. ALL CONC. ANCHORS SHA41,.-AEA, W/ 1/2 INCH DIA. WASI�bk*S'.;:Ad,IN. ED. OF 14 SCR55W'•MESH. ,X, LIVE LOADS 5'•#F OTHER POSITIVE OF CONCRETE SLAB OR FOOTINGS. INTO SOLID CONIC. REGARDLESS OF PROVIDED 5. CONTRACTOR IS RESPON' 9e:.`4 INSULATE ALUak--.MEMBERS FROM DISSIMILAR METALS TO PREVENT ELECTROLYSIS:;:; .' 6. ALUM. IN CON -TAbT:--W/ COPlEi:;bjt'•;;N(0GD.-:8{}F1{L-A§E PROTECTED W/ HEAVY BOOTED BITUMINOUS PAINT OR M{ijT'R•;}fiIJ3jT MEfHJrC�t kilr:•.lA f[jER OR THE WOOD SHALL BE PAINTED W/ TWO COATS OF ALl7AA ;:144i)�l .'.PAIN ")4}q 7FI : 1fSINTS SEALED W/ A GOOD QUALITY CAULKING. 7. ALL DOORS TO 13:.f'Lt OlOS1NG AND LATCHING, W/5 FT. HIGH DOOR HANDLES WHERE POOL OR SPA. ba3T-..-.DOOR LY3lsA LpN: i. 202 DOOR JAMB PLACEMENT IS OPTIONAL. ALL OTHER COLUMNS 8. PLAN SUPERCEDES ANY REQ.'S SHOWN ON ARE NOWISTRUCTURAL MEMBERS INTERCHANGEABLY. STRIP FOOTING SCHEDULE MkY;:RE::;tISED, :RETt`f0A .'Vt NDAT1ONS TO BE 250OPS1 MIN, EXCEEbJNd:;TH S SPECIFICATION MAY BE PER LOC4"bUILDING CODES. U,Rt k�:;Jr'dTj &1D15:• COLUMNS ................. *AL 6005-T5 S10NS .........................AL 6063-T5 r;:stiEi ...................................'SAL 3003-H16 RO6t, RIVETS, WASHERS ......AL 2024-T4 a'TENERS TO BE ALUM., NON-MAGNETIC UM PLED ATSTEEL OR STRUCTURE FOOTING (MIN.) REBAR WIDTH X DEPTH SCREEN ROOF W/ 12"X10" 2-#5 UP TO 7LB SCREEN ROOF W/8LB 12"X12" 2-#5 SCREEN ROOF W/ 12"X16" 2_#5 9LB OR 10LB ALL SOLID ALUMINUM 12"X16" 2-#5 ROOF S STEE CA DMI SL, HEADED (NYLO-TEC OR PRO-TECT) FOOTING SIZES SMALLER THAN SHOWN MAY BE USED WITH SITE SPECIFIC PLAN. *UNLESS OTHERWISE NOTED F.B.C. 2014 EDITION & ASCE 7.10 3" TO FRONT ELEVATION INTERIOR FASTENING 4 - #10 X 1 1/2" SMS. INTO SCREW SLOTS EA. SIDE Z2" CHAIR RAIL CONNECTION a CHAIR RAIL PER SCHEDULE 6005-T5 /8" X 3" LG. MIN. NO SIDES OF COL 1 TO COL 3/8"X2 1/2' LG. TO CONC. 2"X2"X7/8" X 3" I.G. MIN. ANGLE TWO SIDES OF COL W/ (6)- #1 TO COL TAP(2)-CON3/8"X2 1/2' LG. TS TO CONIC. (6) - #10 X 3/4" SMS, (3 EA. SIDE) 2". X 2" X .062" RECEIVING CHANNEL W/ �/� 6 - #10 X 3/4 SMS. TO I ' I SIDE bF COLUMN Z2" RAIL* ALT. CHAIR RAIL CONNECTION * CHAIR RAIL PER SCHEDULE FASTENING SCHEDULE #1 - #14 TEK SCREW/HEX HEAD #2 - #10 S.M.S./ HEX HD. �3 - 1/4" X 2 1/4" TAPCON ANCHOR 4 - 1/4 BOLTS/WASHER/NUT 5 - CLIP ANGLE,.125 MIN. THICKNESS 6 - #12X1" LG. S.M.S./HEX HD. 7 - 1 /4 X 3 LAG 8 - 1 /4" LAG*, WITH 1 " WASHER 9 - #10 X 1 1/2" S.M.S./HEX HD. 12 - CLIP ANGLE, 3/32 MIN.THICKNESS *LAG BOLT LENGTH TO BE 1" LONGER THAN ALUMINUM PANEL THICKNESS DATE 09/30/15 S STEE CA DMI SL, HEADED (NYLO-TEC OR PRO-TECT) FOOTING SIZES SMALLER THAN SHOWN MAY BE USED WITH SITE SPECIFIC PLAN. *UNLESS OTHERWISE NOTED F.B.C. 2014 EDITION & ASCE 7.10 3" TO FRONT ELEVATION INTERIOR FASTENING 4 - #10 X 1 1/2" SMS. INTO SCREW SLOTS EA. SIDE Z2" CHAIR RAIL CONNECTION a CHAIR RAIL PER SCHEDULE 6005-T5 /8" X 3" LG. MIN. NO SIDES OF COL 1 TO COL 3/8"X2 1/2' LG. TO CONC. 2"X2"X7/8" X 3" I.G. MIN. ANGLE TWO SIDES OF COL W/ (6)- #1 TO COL TAP(2)-CON3/8"X2 1/2' LG. TS TO CONIC. (6) - #10 X 3/4" SMS, (3 EA. SIDE) 2". X 2" X .062" RECEIVING CHANNEL W/ �/� 6 - #10 X 3/4 SMS. TO I ' I SIDE bF COLUMN Z2" RAIL* ALT. CHAIR RAIL CONNECTION * CHAIR RAIL PER SCHEDULE FASTENING SCHEDULE #1 - #14 TEK SCREW/HEX HEAD #2 - #10 S.M.S./ HEX HD. �3 - 1/4" X 2 1/4" TAPCON ANCHOR 4 - 1/4 BOLTS/WASHER/NUT 5 - CLIP ANGLE,.125 MIN. THICKNESS 6 - #12X1" LG. S.M.S./HEX HD. 7 - 1 /4 X 3 LAG 8 - 1 /4" LAG*, WITH 1 " WASHER 9 - #10 X 1 1/2" S.M.S./HEX HD. 12 - CLIP ANGLE, 3/32 MIN.THICKNESS *LAG BOLT LENGTH TO BE 1" LONGER THAN ALUMINUM PANEL THICKNESS DATE 09/30/15 ENGINEERING BUSINESS CA 00009677 TARNOWSKI SCALE N.T.S. %ENGINEERING SH c CIVIL & STRUCTURAL ENGINEERING 7360 N.W. 5th Street Phone (954) 727 - 2027 Plantation, FL 33317 Fox (954) 727 - 9644 7• pp� C.T. P.E. THIS DOCUMENT IS THE PROPERTY OFTARNOWSKI ENGINEERING, IAI\ItlOWSKI STRUCTURAL ENGINEER - FIA. UC. 0050662 INC. AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN CONSENT OF TARNOWSKI ENGINEERING, INC. ALL CALCULATIONS ARE BAS', ON THE FOLLOWING CRITERIA„ .1. FOR SCREENING WITH 18X14X.013" MESH SPANS ARE BASED ON LOADS FROM FBC TABLE 2002.4 LOADS ARE APPLIED SIMULTANEOUSLY TO WALL & ROOF 2. 30 PSF ROOF LOAD, 19 PSF WALL LOAD 3. WIND LOAD = 160 M.P.H. / EXPOSURE B / CATEGORY R 4. DESIGN MEETS L/120 DEFLECTION REQUIREMENTS COLUMN SCHEDULES WITH SOLID ALUMINUM ROOF (OPEN WALLS) COLUMN TYPE: 3X3X.090 LOADING = 33 PSF AREA = 1.08 K = 1.5 1 = 1.52 45 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21.3 19.1 17.4 16.1 15.1 14.2 13.5 12.9 12.3 11.8 11.4 11.0 10.7 10.3 10.1 9.8 9.5 19.1 17.1 15.6 14.4 13.5 12.7 12.1 11.5 11.0 10.6 10.2 9.8 9.5 9.2 9.0 8.7 8.5 N 15.6 14.2 13.2 12.3 11.6 11.0 10.5 10.1 9.7 9.3 9.0 8.7 8.4 8.2 8.0 7.8 16.1 14.4 13.2 12.2 11.4 10.7 10.2 9.7 9.3 8.9 B.6 8.3 8.1 7.8 7.6 7.4 7.2 15.1 13.5 12.3 11.4 10.7 10.1 9.5 9.1 8.7 8.4 B.1 7.8 7.5 7.3 7.1 6.9 6.7 14.2 12.7 11.6 10.7 10.1 8.6 8.2 7.9 7.6 7.3 7.1 6.9 6.7 6.5 6.4 1 13.5 12.1 11.0 10.2 9.5 9.0 8.5 8.1 7.8 7.5 7.2 7.0 6.7 6.5 6.4 6.2 6.0. 11 12.9 11.5 10.5 9.7 9.1 8.6 8.1 7.8 7.4 7.1 6.9 6.5 6.4 6.2 6,1 5.9 5.K 12 12.3 11.0 10.1 9.3 8.7 8.2 7.8 7.4 7.1 6.8 5.6 6.4 6.2 6.0 5.8 5.6 5.1%: 14 11.4 10.2 9.3 8.6 8.1 7.6 7.2 6.9 6.6 6.3 6.1 5.9 5.7 1 5.5 5.4 5.2 5.1:• 16 10.7 9.5 B.7 8.1 7.5 7.1 6.7 6.4 6.2 5.9 5.7 5.5 5.3 1 5.2 5.0 4.9:: 4.8 ' 18 9:0 8.2 7.6 7.1 6 6.1 5.8 5.6 5.4 5.2 5.0 4.9 4.7 R: '•:• 4.5 20 9.5 8.5 7.8 7.2 6.7 6.4 6.0 5.7 5.5 5.3 5.1 4.9 4.8 4.6 4.5 •'• d 4 : •'::3:. TABLE GIVES MAX. COLUMN HEIGHT FOR GIVEN COLUMN SPACING AND BtAM LUAU *BEAM LOAD FACTOR = THE SUM OF 1/2 THE SPAN OF THE LONGEST MEMBER ATTACHED TO EACH SIDE OF THE CARRY BEAM. COLUMN SCHEDULES WITH SOLID ALUMINUM W COLUMN TYPE: 4X4X.090 LOADING = 33 PSF AREA = 1.45 COL SPACING 4 5 6 7 8 9 10 11 12 13 14: •. 15 T;6' :;: I�/';: .1B• ;.:,1'9; .'.:20 4 1 33.21 29.7 27.1 25.1 23.5 22.1 21.0 20.0 19.2 18.4 1,7.$. :17..1 16:6 ::1.6:1'• •: b.: ::7•S.2• ' 14.9 5 1 29.71 26.6 24.3 22.5 21.0 19.8 18.8 17.9 17.1 16.5 •tS. '.'•:S&Z 4.9 '•:•A'4•. k(i• 6 :1 13.3 6 27.1 24.3 22.1 20.5 19.2 18.1 17.1 16.4 15.7 15.0 14. '• :14' • :'• 13.6 1 ,'1 •:i• .8: '::1 .4 12.1 7 25.1 1 22.5 20.5 19.0 17.8 16.7 15.9 15.1 14.5 13.9 13.4• :'13'a': fi2.6 12.2 i1.8 11.5 11.2 8 23.5 21.0 19.2 17.8 16.6 15.7 14.9 14.2 13.6 .•. 3 0 12.6 ' 1 '1 :•x.Y:!• 11.4 11.1 10.8 10,5 9 22.1 19.8 1 B.1 16.7 15.7 13.4 12.8.. :1.1:8. 1 .'4:.: •1:1: : 10.7 10.4El 10 21.0 18.8 17.1 15.9 14.9 14.0 13.3 12.7 1 .5:::T1: • :.1.1 :':SD : •': dfi• :7 •.2 9.9 11 20.0 17.9 16.4 15.1 14.2 13.4 12.7 12.1 L7: '•:.:15:% ::1D ':•..43: •:iOD•:•9:7 9.4 12 19.2 17.1 15.7 14.5 13.6 12.8 12.1 11.6 113? ':•10 6 ': D 2: rTi r: :91i'•: :'9.3 9.01415.9A13.4 126 10.7 10.2 '.� .: -.;95: 9.2 ' 'BT3•:: ' 8.6 8.416 16.6 14.9 13.6 12.6 11.7 11.1 10.5 : t0. • •9.6 9:2:.'•$ '•:..8.6 8.3 8.1 7.818 7 14.0 12.8 11.8 11.1 : ' : 9c4. :9'0 B. :::'J&.:': 78.3 7.8 7.6 7.420 14.9 13.3 12.1 11.2 105 99:8.6: 8.2 fl:: •:7 J•. 7.4 7.2 7.06 TABLE GIVES MAX. COLUMN HEIGHT FOR *BEAM LOAD FACTOR = THE SUM OF 1, ATTACHED TO E COLUMN SCHEDULES AND INUM ROOF (SCREE BEAM LOAD FACTOR* BEAM LOAD FACTOR* COLUMN HEIGHT MAXIMUM COLUMN•f4tJG}1f;1{U/10'ALUMINl7t�aQ¢F::•,':: MAXIMUM COLUMN HEIGHT W/20'ALUMINUM ROOF COLUMN 4.0' 4.5' 5;-0;: ;:5a:::'::g;�•`:; :,$ 5' 7:0`::;7;5 8.0' COLUMN 4.0' 4.5' 5.0' S.5' 6.0' 6.5' 7.0' 7.5' 8.0' 2X3X060 7.6 7.3 7:(1::;:;';6;g:',::1) •::;:::fi;5r;,:•$;3 ":'6.2 6.0 2X3Xo60 7.5 7.1 6.7 6.4 6.2 5.9 5.7 5A 5.1 3X3X090 9.5 9.1 8.8':.;:'.FT;it: 7.7 7.5 3X3X090 9.5 9.1 8.8 8.5 8.3 8.1 7.9 7.6 7.4 3X3X125 10.5 ::10.1 9.7'•1?::$;A'•;: , fi:2:;•.:;;8 5;;:::8.7 8.5 8.3 3X3X125 10.5 10.1 9.7 9.4 9.2 8.9 8.7 8.5 8.3 4X4X090 12;Q;:: 11 3, 11.9 :f 4;a': ;':?;f7: 10.9 10.6 10.4 10.1 4X4X090 12.8 12.3 11.9 11.5 11.2 10.9 10.5 10.1 9.8 4X4X125 ;1'4'2'::7'3'6 13.1 12.•7.•: 1;4 12.0 11.7 11.5 11.2 4X4X125 14.2 13.6 13.1 12.7 12.4 12.0 1 11.7 11.5 11.2 4LB ;:;;:'6,tr'::.' 8.1 7.6 ?2;:::6;&. 6.6 6.3 6.1 5.8 4LB 8.3 7.7 7.1 6.6 6.1 5.7 5.3 4.9 4.1 �p.4 9.8P274 ::$:J 8.5 8.2 7.8 7.6 5LB 10.7 10.0 9.4 8.9 8.4 8.0 7.6 7.2 6.8 10.6 ;•'9.6 9.2 8.9 8.5 8.2 6LB 11.6 10.9 10.3 9.7 9.2 8.8 8A 7.9 7.5. ::L'•,B';::' 13:i :•;:1;2;8:• 12.2 11.1 10.6 10.2 9.8 9.5 7LB 13.4 12.5 11.8 11.2 10.6 10.1 9.7 9.3 ;$;9;•;: 8} 22.2'•;•21:¢;::kT;6 19.4 18.9 18.4 18.0 17.6 8LB 22.2 21.4 20.6 20.0 19.4 18.9 18.4 17.8;'•::j.Y;'L:;• 9LB 24.4 23:$;'•:;^2.:8r 21.3 20.6 19.8 19.1 18.5 9LB 24.4 23.5 22.6 21.8 20.9 20.1 19.3 18.7 9LBH 26.4 25.'a•;:;245 23.0 22.4 21.9 21.4 20.9 9LBH 26.4 25.3 24.5 23.7 23.0 22.4 21.9.•:91:4 10L6 30.4 29.3 '28.2 26.6 25.9 25.2 24.7 24.1 10L6 30.4 29.3 28.2 27.4 26.6 25.9 25.' �S t':7' 24.1'' TABLE GIVES MAX. COLUMN HEIGHT FOR GIVEN COLUMN SPACING AND BtAM LUAU FOR LONGER SPANS SEE SITE SPECIFIC ENGINEERING. NOTE: THIS TABLE APPLIES TO BOTH BEARING AND NON BEARING WALLS FOR HORIZONTAL WIND LOADS CONTROL IN DESIGN. 2X4X.050 MAY BE USED IN LIEU OF 4LB, 2X5X.050 MAY BE USED IN LIEU OF 5LB. **ALL CALCULATIONS ARE BASED ON 6005-T5 ALUMINUM ALLOY **1/3 STRESS REDUCTION NOT USED IN CALCULATIONS **LINEAR INTERPOLATION BETWEEN COLUMN SPACING IS ALLOWED CHAIR Rt>�.HEDULE MAiCIMUM R'AIL'SI?irP1;:::'•:. LOAD RAIL ; :;::q:q 5.0' sia:: ;:Y:U`::''•:8•D' >FACTOR* 202''.;;;;;fx'• 5.9 5.4''::3:I}:'.:':d.7 2X3XO*,.: 9';8': 1 8.7 8.0 1;4;;' Fi.9 :2X3xoso::7;fn:.:7.o-2:...9.4 6.i 8.1 RAIL LENGTH �(�1X050. ;:1'} Ili i'•i'0't:f:: v; 3;5:; :::.8.8 8.2 10.0 9.4 14FA7OR: = 1/2''fHE DISTANCE TO CHAIR RAIL OR GROUND BELbTHE DISTANCE TO CHAIR RAIL OR ,BEAM ABOVE SCREEN FABRIC DETAIL SHEET: 18X14 MESH I EXPOSURE B 1 160 MPH I F.B.C. 2014 EDITION 18X14 MESH LE FOR SOLID ALUMINUM ROOFS MAXIMUM BEAM SPAN BEPTPR:;; :::;4::::. 5.'::';•: `.¢'::1 7' 8' 9' 10, 12' 14' 16, 18, 20' 2X4X125'- : }•d,' *.. ',;:'9. ..-., :: 9.01 8.6 8.2 7.9 7.6 7.1 6.8 6.5 6.1 5.8 `•2X125 '12;4'•; :;1 j;:S 10.9 10.3 9.9 9.5 9.1 8.6 8.2 7.6 7.2 6.8 :•' SLB,;':i•.;11.1 '10.3 9.7 9.2 8.8 8.4 8.0 7.3 6.8 6.3 6.0 5.6 11.9 11.2 10.7 10.2 9.6 9.1 8.3 7.7 7.2 6.8 6.4 14.7 13.6 12.8 12.1 11.3 10.7 10.1 9.2 8.6 8.0 7.5 7.1 19.1 17.7 16.7 15.8 15.1 14.5 14.0 12.8 11.9 11.1 10.5 9.9 21.0 19.4 18.3 17.4 16.6 16.0 15.2 13.9 12.8 12.0 11.3 10.7 ;::•9LBH 22.6 21.0 19.8 18.6 18.0 17.3 16.7 15.5 14.3 13.4 12.6 12.0 10L6 26.1 24.3 22.8 21.7 20.7 19.9 19.2 18.1 16.7 15.6 14.7 1 14.0 TABLE GIVES MAX. BEAM SPAN FUR GIVEN BEAM LUAU *BEAM LOAD FACTOR = THE SUM OF 1/2 THE SPAN OF THE LONGEST MEMBER ATTACHED TO EACH SIDE OF THE CARRY BEAM. 2X4X.050 MAY BE USED IN LIEU OF 4LB, 2X5X.050 MAY BE USED IN LIEU OF 5LB. BEAM LOAD FACTOR* BEAM LENGTH B/T COLUMNS CARRY BEAM SCHEDULE FOR SOLID ALUMINUM ROOFS (SCREEN WALLS) WITH ROOF UP TO 10' WITH ROOF UP TO 20' RAIL 4.0' 5.0' 1 6.0' 7.0' 8.0' RAIL 4.0' 5.0' 6.0' 7.0'R4. 3X2X050 5.1 5.0 4.9 4.8 4.7 3X2X050 3.9 3.9 3.8 3.8 2X3X097 6.6 6.6 6.6 6.5 6.3 2X3X097 5.3 5.2 5.2 5.1 2X4X050 6.1 6.0 5.8 5.7 5.6 2X4X050 4.7 4.7 4.6 4.52X4X125 8.0 8.0 80 8.0 8.0 2X4X125 7.3 7.2 7.0 6.92X5X050 7.1 6.9 6.7 6.6 6.4 2X5X050 5.5 5.5 5.4 5.3 2X5X125 8.0 8.0 8.0 8.0 8.0 2X5X125 8.0 8.0 8.0 8.0 8.0 TABLE GIVES MAX. BEAM SPAN WK GIVEN BtAM LUAU *BEAM LOAD FACTOR = THE DISTANCE FROM CARRY BEAM TO CHAIR RAIL BELOW 2X4X.050 MAY BE USED IN LIEU OF 4LB, 2X5X.050 MAY BE USED IN LIEU OF 5LB. BEAM LOAD FACTOR* BEAM LENGTH B/T COLUMNS DATE / ENGINEERING BUSINESS CA 00009677 TARNOWSKI ENGINEERING CIVIL & STRUCTURAL ENGINEERING 360 N.W. 5th Street Phone (954) 727 - 2027 Plantation, FL 33317 Fax (954) 727 - 9644 THIS DOCUMENT IS THE PROPERTY OF TARNOWSKI ENGINEERING, WITHOUT WRITTENOTBE REPRODUCED IN WHOLE ORIN PART CONSENT OFFTARNOWSKI ENGINEERING, INC. SCAL , :C:T: TARNOWSKI, .E. STRUCTUPo>L ENGINEER 050662 6005-T5 07' �01 15 N.T.S. . 62, [160B] - FIA. UC. 0