HomeMy WebLinkAboutGENERATOR ADDITION RISER DIAGRAMABBREVIATIONS:
A AMPERE - MCB MAIN CIRCUIT BREAKER
AC ALTERNATING CURRENT MCC MOTOR CONTROL CENTER
A/C AIR CONDITIONING MTS MANUAL TRANSFER SWITCH
AL ALUMINUM MLO MAIN LUGS ONLY
AHU AIR HANDLING UNIT NEC NATIONAL ELECTRICAL CODE
ATS AUTOMATIC TRANSFER SWITCH NEMA NATIONAL ELECTRICAL MANUFACTURERS
AFCI ARC FAULT CIRCUIT INTERRUPTER ASSOCIATION
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE NFPA NATIONAL FIRE PROTECTION ASSOCIATION
C CONDUIT PLCS PLACES (QUANTITY) -
CU COMPRESSOR UNIT PNL PANEL
COVB CITY OF VERO BEACH PVC POLYVINYL CHLORIDE CONDUIT
DC DIRECT CURRENT RMC RIGID METAL CONDUIT
EXIST EXISTING RTU ROOF TOP UNIT
FPL FLORIDA POWER & LIGHT TYP TYPICAL
G GROUND TEMP TEMPORARY
GFCI GROUND FAULT CIRCUIT INTERRUPTER UL UNDERWRITERS LABORATORY
IRC INDIAN RIVER COUNTY V VOLT
KVA KILOVOLTAMPERE VA VOLT AMPERE
KW KILOWATT W WATT
MC METAL CLAD CABLE XFMR TRANSFORMER
I�(INTIERIOR)Ij INTERIOR
) ii
ERIOR
i HOUSE i HOUSE
(EXISTING) 300 AMP RATED FPL (EXISTING) ( I i PANEL I PANEL 1
METER SOCKET LOCATED BACK 300 AMP i I
TO BACK FROM THE (2)150 AMP METER I '
BREAKER PANELS. SOCKET
12012401,V—
SEE SCOPE OF —
WORK NOTES
(NEW) (NEW)
150 AMP 150 AMP
GENERAC GENERAC
EXISTING FPL FEEDER SE RATED SE RATED
EXISTING() ATS ATS
#4 BARE CU
IN 1/2" CONDUIT
COLD WATER BOND
SEE SCOPE OF
WORK NOTES
4—
EXISTING
j #4 BARE CU
IN 112" it
�I CONDUIT
(2)5/8"X8'
CU GROUND
ROD
SCOPE OF WORK:
• INSTALL THE (2)150AMP SE RATED ATS INSIDE THE GARAGE BELOW THE (2)
EXISTING MAIN PANELS.
• SEPARATE NEUTRALS AND GROUND WIRES IN EACH MAIN PANEL AND RE -FEED
MAIN PANELS FROM ATS.
• FORM AND POUR PAD FOR GENERATOR.
• PROVIDE AND INSTALL (1) 27kW GENERAC LP GAS GENERATOR
• PROVIDE AND INSTALL CONDUIT AND CONDUCTOR FROM NEW GENERATOR TO
NEW ATS.
• LOAD SHED (2) HVAC SYSTEMS, AND (1) WATER HEATER
• GENERATOR LP GAS CONNECTION BY FERRELLGAS AS A SUBCONTRACTOR UNDER
THIS PERMIT.
• NEW LP TANK TO BE PROVIDED AND INSTALLED BY FERRELLGAS CONTRACTOR
UNDER A SEPARATE PERMIT.
• NO NEW BRANCH CIRCUIT LOADS SHALL BE ADDED TO HOUSE PANEL UNDER THIS
SCOPE OF WORK.
LOAD SHED:
(1) 3.0 TON AC CONTROL CIRCUIT
(1) 3.0 TON HEAT PUMP
(1) 5.0 TON AC CONTROL CIRCUIT
(1) 5.0 TON HEAT PUMP
(1) WATER HEATER
2" PVC CONDUIT
(2) #1/0 THHW CU (LINE)
(1) #1/0 THH W CU (NEUTRAL)
(1) #6 THH W CU (GROUND)
314" PVC CONDUIT
W/ (7) #14 THHN CU.
(NEW) GENERATOR
LIQUID COOLED 27KW
GENERAC
® 125
(EXISTING) —#4 BARE CU
WATER LINE IN 11Y CONDUIT
COLD WATER BOND
GENERAL NOTES:
• THE ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL SERVICE ROUGH IN AND INSTALLATION
DETAIL WITH THE LOCAL UTILITY POWER COMPANY.
• THIS ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE LOCAL ORDINANCE, AND
THE NATIONAL ELECTRIC CODE, PRESENTLY IN EFFECT.
• ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED IN A NEAT AN CRAFTSMAN LIKE MANNER BY
PERSONS SKILLED IN THE ELECTRICAL TRADE, AND SHALL BE DONE UNDER THE SUPERVISION OF A MASTER ELECTRICIAN
LICENSED IN THE STATE OF FLORIDA
• THIS ELECTRICAL INSTALLATION SHALL BE PROTECTED FROM PHYSICAL DAMAGE AND SECURELY SUPPORTED AND
FASTENED, WITH WORKING SPACE PER NEC 11026.
• PVC SCHEDULE 40 CONDUIT SHALL BE USED UNDERGROUND, IN OR BELOW CONCRETE AND WHERE EXPOSED NOT
SUBJECT TO DAMAGE. PVC SCHEDULE 80 CONDUIT SHALL BE USED WHERE EXPOSED, SUBJECT TO DAMAGE.
• ALL MATERIAL SHALL BE NEW, FREE FROM DEFECT AND SHALL BE LISTED AND BEAR THE LABEL OF A RECOGNIZED
TESTING LABORATORY,
• GROUNDING PER NFPA 70 2011 EDITION ARTICLE 250.
• STANDBY SYSTEM INSTALLATION PER NFPA 70 2011 EDITION ARTICLE 702, AND MANUFACTURER INSTALLATION
INSTRUCTIONS.
LOAD MANAGEMENT
LCM" LOAD SHED
LOAD MANAGEMENT TECHNOLOGY ALLOWS THE LOAD CONTROL MODULE TO MONITOR GENERATOR PERFORMANCE AND
ONLY SHED LOADS WHEN ABSOLUTELY NECESSARY BY MONITORING GENERATOR CURRENT AND FREQUENCY. BY ONLY
SHEDDING THE NONESSENTIAL CIRCUITS, THE ESSENTIAL CIRCUITS ARE ALWAYS POWERED. LOADS ARE SHED THROUGH
INTERRUPTION OF INDIVIDUAL CONTROL CIRCUITS (AHU/AC) AND POWER CIRCUITS (RANGE AND WATER HEATER).
NO SCAT E GENERATOR ADDITION RISER DIAGRAM
SCANNED
BY '
STLUCIE COUNTY
sEenstuN, PL axe5e
81 N Report
R.I.CN.1ka oe.S• 240
G—.WFeelUdo• PMP—
swN met m (NEC 228I Pw IV
(Pall III MAWWo=dracve.ndaB IdWI. BM Vinotr%Into nmo.)
G.ma uBwq a Recepucna
Sgmm Fwteps Bahg Cavea PlR) 9998
&.mADPlallm=fa
4
U-4 CLWha mioryCimti 1
GENERAC'
E-�
f
i-0pfIRM AMo
lama i�r4
(
my
lam
a
ae
14aao•+.
to
1.0
amk70P
- as
x
11.0
ao
x
a o
PM
Pm Reaar
fle
x
as
W.mr H.•
eo
x
a.0
WMv Iw
X 1
X
as
dtT "
1.9 .e
Ia
RaN1WXW2.IMm
ae
as
Pod Petry
10
2A
We9 P-P
1.5
1.5
111,110 EPhnE•d
It=
ComkW a
toms pa'0
(arya)
PAPV
en
ao
ao hn ur
x ao
x
ao
Muawd Urkatm
Iftwr a%
a wet wet
tom. pool
(-P)
v
lam
N. +o
ao
20a
RealPWp(e TLn)
% ao
40
x
U
LAW NEC
&.omvytgClam (k" B.@.-
GW.W UO&g aR.MVW.. 1014
Ftr.61•"PemApp9.rowfl Mdtn 81.4
Sion d.I G.mrel la•ea 611.7 me
aodna a o
WeOVNM —dfW=) 0 0
lnadot HemryaCPWna a o
StrVband m m*&mnadaof NECAnW.M, Pert N 280
Elea9.n oe
M61t—*. Oma.ly 1ormotorahMal65n9.leanf! 20
BN 1atl r.pdnt. 97946a
27 kW Ommmc Model Oerrermor Raaomm Wed
Z _ ON
Its
Ix N
HZMc)
U ¢ LL o
ail
W Q Q 1h
J
Q
m
co LU
U)
O
U
rn
n Uo
�OJ av w
W 0
f� 0 Q
1 = '
CID
����\\�l• �% �� i � W o�i
OLLZU�
pF- gLL
J
� r \� i amWv
RgV\ "f 5p�0p\ao.0 i Z�l�
uS�B KSIO ��g� p .Ja
M so 3cN�-
yy0 \N5P z o
D-
E1
05/22/2017
v¢c
PARTIAL SITE PLAN
DRILL CLEAN
DRILL
1/4"
DEEPER
THAN
ANCHOR
EMBEDMENT
DRILL BIT SIZE: 112"
3-5 X
54"
TIGHTENING MIN. ANCHOR
TORQUE 45fLibs. EMBEDMENT: 2-1/2"
NOTE:
THE USE OF A CARBIDE DRILL BIT CONFORMING TO ANSI
STANDARD B212.15 IS RECOMMENDED.
I--- 32" --
TOP VIEW
® 16" MIN.
I-- 32" ---�
LEFT ELEVATION
SPECIFIC NOTES:®
26-1 (2) EXISTING 150 AMP HOUSE PANELS. (2) NEW 150 AMP
SE RATED AUTOMATIC TRANSFER SWITCHES BELOW
(NOT SHOWN FOR CLARITY).
26-2 NEW 500 GALLON LP TANK LOCATION.
6° MIN.
F 54° —1{
FRONT ELEVATION
N
W E
1�2„2 _>._0 " GENERATOR PAD DETAIL
S
Q. J
O
po 9LLI
a
z i=
�
y 0
co
OD
LLI 0)
OOg
q0 LL
= J l L
mWU
Z�Q�J
W LU
m .1 H
U3
w w
z ^o
a
E2
05/22/2017
SIM-
2OF2