HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and. Professional Regulation - Residential Performance Method
Project Name: BLUE GARAGE
Builder Name:
Street
Permit Office: ST LUCIE COUNTY
City, State, Zip: , FL,
Permit Number:
Owner.
Jurisdiction:
Design Location: FL, Fort Pierce
County;: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
9. Wall Types (1309.1 sgft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 826.67ft2
3. Number of units, If multiple family
1
b. Frame - Wood, Adjacent
c. N/A
R=13.0 482AO ft2
R= ft2
4. Number of Bedrooms
0
d. N/A
R= ft2
5. Is this a worst case?
No
10. Ceiling Types (468.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 468.00 ft2
6. Conditioned floor area above grade (ft2)
468
b. N/A
R= ft2
Conditioned floor area below grade- (ft2)
0
c. NIA
R
f�
7. Windows(24.0 sgfL) Description
Area
11. Ducts
Fi
a. U-Factor: Sgl, U=0.65
24.00 ft2
SHGC: SHGC=0.25
b. U-Factor. N/A
ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
18.0 SEER:18.90
c. U-Factor: N/A
fF
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. N/A
fe
a Electric Heat Pump
17.0 HSPF:10.70
SHGC:
Area Weighted Average Overhang Depth:
2.000 ft.
Area Weighted Average SHGC:
0.250
14. Hot water systems
8. Floor Types (468.0 sgft.)
Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Ed9e Insulation
R=0;0 468.00 ft2
b. Conservation features
EF: 0.980
b. WA
R= ft2
None
c. N/A
R= ft2
15. Credits
None
Glass/Floor Area: 0.051
Total Proposed Modified Loads: 19.81
PASS
Total Baseline Loads: 26.06
I hereby certify that the plans and specifications covered by
Review, of the plans and
STgTB
this calculation are in compliance with
the Florida Energy
specifications covered by this1+
o4'tuE
p� •,
Code.
t
calculation indicates compliance
ti `O
with the Florida Energy -Code.
nrur"y=.•i"=° �`�= ;�
PRE PA" BY:
Before construction is completed
DATE: "
this building will be inspected for
i `t
compliance with Section 553.908
a o
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
COD WE
OWNER/AGENT•. -
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by.the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordancewith R403.2.2.1.
- Compliance requires an Air Barrier and "Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with'R402.4.1.2.
FI
®py
5/4/20173:08 PM EnergyGauge® USA - FlaRes2014 Section R405A.1 Compliant Software Page 1 of 4
1*,
FORM R405-2014
PROJECT
Title: BLUE GARAGE
Bedrooms: 0
Address Type:
Street Address
Building Type: User
Conditioned Area: 468
Lot #
Owner.
Total Stories: 1
Block/SubDivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County.
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zp:
Family Type: Single-family
FL,
New/Existing: -New (From Plans)
Comment:
CLIMATE
J
IECC Design Temp
Int Design Temp Heating
Design Dally Temp
Design Location
TMY Site Zone 97.5 % 2.5 %
Winter
Summer Degree Days. Moisture
Range
FL, Fort Pierce FL_VERO BEACH_MUNI 2 39 90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
468 6271.2
SPACES
Number Name
Area Volume. Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 BATHROOM
78 1045.2 No 0
1 Yes
Yes
Yes
2 OFFICE 2
130 1742 No 0
1 Yes
Yes
Yes.
3 BREAKROOM
104 1393.6 No 0
1 Yes
Yes
Yes
4 OFFICE
156 2090 No, 0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
I Slab -On -Grade Edge Insulation BATHROOM 19 ft 0
78 ft2
1 0
0
2 Slab -On -Grade Edge Insulation OFFICE 2 loft 0
130 ft?
1 0
0
3 Slab -On -Grade Edge Insulation BREAKROOM 8 ft 0
104 W
1 0
0
4 Slab -On -Grade Edge Insulation OFFICE 25 ft 0
156 W
1 0
0
ROOF
.Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
# Type
Materials Area Area Color
Absor.
Tested
Tested Insul.
(deg)
1 Hip
Metal 507 ft2 0 ft2 Light
0.6
No 0.9
No 0
22.6
ATTIC
y # Type
Ventilation Vent Ratio (1 in).
Area
RBS IRCC
1 Full attic
Vented 150
468 ft2
N N
514/2017.3:08 PM. EnergyGaugeO USA- FlaRes2014 Section R405.4.1 Compliant Software. Page 2 of 4
FORM R40.5-2014
CEILING
#
-Calling Type Space R-Value Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) BATHROOM 30 Blown
78ft2
0.1
Wood
2
Under Attic (Vented) OFFICE 2 30 Blown
130 ft2
0.1
Wood
3
Under Attic (Vented) BREAKROOM 30 Blown
104 ft2
0.1
Wood
4
Under Attic (Vented) OFFICE 30 Blown
156ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width Height
Sheathing Framing Solar
Below
_ 1
N
Exterior Concrete Block - Ext Insd3ATHROOM 4.1 13 0 13 4
173.3 ft2
0
0 0.6
0
2
E
Exterior Concrete Block - Ext InstBATHROOM 4.1 6 0 13 4
80.0ft2
0
0 0.6
0
3
E
Exterior Concrete Block - Ext Insul OFFICE 2 4.1 10 0 13 4
133.3 ft2
0
0 0.6
0
4
E
Exterior Concrete Block - Ext'Insd$REAKROO 4.1 8 0 13 4
106.7 ft2
0
0 0.6
0
_ 5
E
.Exterior Concrete Block - Ext Insul OFFICE 4.1 12 0 13 4
160.0 ft2
0
0 0.6
0
_ 6
S
Exterior Concrete Block - Ext Insul OFFICE 4.1 13 0 13 4
173.3 ft2
0
0 0.6
0
_ 7
W
Garage Frame: Wood OFFICE 13 36 13.4
482A ft2
0
0 0.600000 0
DOORS -
#
Omt Door Type Space Storms U-Value
Width
Height
Area
Ft
In
Ft In
1
S Insulated OFFICE None .39
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Omt ID Frame Panes NFRC U-Factor SHGC Area
Depth _
Separation
Int Shade
Screening
1
E 4 Metal Low-E Single Yes 0.65 0.25 9.0 ft2
2 it 0 In
1 ft 4 In.
None
None
2
S 6 Metal Low-E Single Yes 0.65 0.25 15.0 ft2
2 ft:0 in
1 ft4 in
None
None
GARAGE
#
Floor Area: Ceiling Area Exposed Wall Perimeter Avg. Wall Height
Exposed (Nall Insulation
1
1044 ft2 384 ft2 36 ft 13.4 ft
13
INFILTRATION
#
Scope
Method SLA CFM 50 ELA EgtA
ACH
ACH 50,
1 Wholehouse Proposed ACH(50) .000596 731.6 40.16 75:53
A351
7
HEATING SYSTEM
#
System Type Subtype Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump Split HSPF:10.7 17 kBtuthr
1
Ductless
514/20173:08 PM EnergyGaugeS USA - FlaRes2014 Section R405.4.1 Compliant Software Page of 4
FORM R405-2014
COOLING SYSTEM
# System Type . "
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit
Split
SEER: 18.9
18 kBtuthr
540 cfm
0.8
1
Ductless
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.98 40 gal 60.9. gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft'
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Jan Feb
Veo�nting Jan Feb
Mar
Apr
May Jun Jul
Jun
Au
Oct
Nov
Nov
Dec
X Maarr
Apr
Mng.
ay Jul
Aug
Sep
Oct
X
Dec
Thermostat 9che_dule: HERS 2006,Reference
Hours
Schedule Type
1
2 3
4 6 6
7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 80
80 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 80:
80 78 78
78
78
78
78
78
78
Heating(WD) AM
65
65 65
65 65 65
65
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
68
68
Heating (WEH) AM
65
65 65
.65 65 65
65
68
68
68
68.
68
PM
68,
68 68
._ .68 68 68
68
68
68
68
68
68.
5/4/2017 3:08 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION. INSPECTION COMPONENT CRITERIA
Project Name: BLUE GARAGE Builder Name:
Street: Permit Office: ST LUCIE COUNTY
City, State, Zip: , FL, Permit Number:
Owner. Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks .or joints in the air barrier shall be sealed.
Air -permeable insulation shall not"be,used as -a sealing material.
Ceiling/attic
The air barrier.in any dropped ceiling/soffit-shall be aligned with the
insulation and any gaps in the air barrier shall be sealed:
Access . penings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Comers and headers shall be insulated and the junctiomof the foundation
Walls
and sill plate•shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation -for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/doorjambs and framing -and skylights and.
Rim 'oists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation, shall be installed to maintain permanent contact with underside.
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached.to the crawlspace walls.
Exposed earth in unvented.crawl spaces shall be covered with a Class I
Shafts, penetrations
Duct shafts, :utility penetrations, and flue shaft openings to exterior or
unconditioned, space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installationreadilyconforms to the available cavity
spaces.
Garage separation
Air sealing,shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
airtight, IC rated, and sealed to the drywall._
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to
available space shall extend behind piping and wiring.
Shower/tub on -exterior wall
Exterior walls adjacent to showers and tubs shall. be insulated and the air
:barrier installed'separating there from the showers -and tubs.
Electrical/phone box. on
The air barrier shall be installed behind electrical or communication boxes or
air sealed 'boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-fioor or drywall.
Fireplace
An air barrier'shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
5/4/2017 3:09 PM EnergyGauge® USA-;FlaRes2014 Section,R405.4.1 Compliant Software Page 1 of 1
1. New construction orexisting
New (From Plans)
0. Wall Types
Insulation
Area
2. Single family ormultiple family
Single-family
a.' Concrete Block -Extlnsul,Exterior
R=4.1
826.67ft2
b. Frame - Wood, Adjacent
R=13c0
482.40 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
o
d. NIA
R=
ft2
5. Is this a worst case?
No
10. Ceiling Types
Insulation
Area
a. Under AttiC (Vented)
R=30.0
-468.00 ft2
6. Conditioned floor area (ft2)
468
b. NIA
R=
ft2
7. Windows" Description
Area
c. N/A
R=
ft2
a. U-Factor: Sgl,1J=0.65,
24.00 ft2
11. Ducts
R ft2
SHGC: SHGC=0.25
b. 'U-Factor. N/A
ft2
SHGC:
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: NIA
ft2
a. Central Unit
18.0
SEER:18.90
SHGC:
d. U-Factor. N/A
ft2
SHGC:
13. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
17.0
HSPFt10.70
Area Weighted Average Overhang Depth:
2.00Q ft.
Area WeightedAverageSHGC:
0.250
8. Floor Types
Insulation
Area
14. Hot water systems
Cap;40gallons
a. Slab -On -Grade Edge -Insulation
R=0.0
468.00 ft2
a. Electric
EF: 0.98
b. NIA
R=
ft2
c. N/A
E2=
ft2
b. Conservation features
None
15. Credits
None
1 certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through,.the above: energy saving:featureawhlch will be installed .(or exceeded).
in this home before final inspection., Otherwise, a new EPL Display Card will .be completed.
based on installed' Code Compliant features.
Builder Signature:. Date:
Address of New Home: City/FL Zip:
"Note: This is not aBuilding Energy Rating. if your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. Contact the EnergyGauge Hotline at (321;)
08-1492 or see the EnergyGauge web site,at energygauge.com for information and a list of certifiedRaters. For
information about the. Florida, Building Cade, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section 11303.1.3 of. the Florida Building Code, Energy Conservation, if not DEFAULT.
6/4/20113 09 PM EnergyGauge® USA - FlaRes2014 - Section R405A.1• Compliant Software Page 1 of 1