Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and. Professional Regulation - Residential Performance Method Project Name: BLUE GARAGE Builder Name: Street Permit Office: ST LUCIE COUNTY City, State, Zip: , FL, Permit Number: Owner. Jurisdiction: Design Location: FL, Fort Pierce County;: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1309.1 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 826.67ft2 3. Number of units, If multiple family 1 b. Frame - Wood, Adjacent c. N/A R=13.0 482AO ft2 R= ft2 4. Number of Bedrooms 0 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (468.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 468.00 ft2 6. Conditioned floor area above grade (ft2) 468 b. N/A R= ft2 Conditioned floor area below grade- (ft2) 0 c. NIA R f� 7. Windows(24.0 sgfL) Description Area 11. Ducts Fi a. U-Factor: Sgl, U=0.65 24.00 ft2 SHGC: SHGC=0.25 b. U-Factor. N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 18.0 SEER:18.90 c. U-Factor: N/A fF SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A fe a Electric Heat Pump 17.0 HSPF:10.70 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (468.0 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Ed9e Insulation R=0;0 468.00 ft2 b. Conservation features EF: 0.980 b. WA R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.051 Total Proposed Modified Loads: 19.81 PASS Total Baseline Loads: 26.06 I hereby certify that the plans and specifications covered by Review, of the plans and STgTB this calculation are in compliance with the Florida Energy specifications covered by this1+ o4'tuE p� •, Code. t calculation indicates compliance ti `O with the Florida Energy -Code. nrur"y=.•i"=° �`�= ;� PRE PA" BY: Before construction is completed DATE: " this building will be inspected for i `t compliance with Section 553.908 a o I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COD WE OWNER/AGENT•. - BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by.the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordancewith R403.2.2.1. - Compliance requires an Air Barrier and "Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with'R402.4.1.2. FI ®py 5/4/20173:08 PM EnergyGauge® USA - FlaRes2014 Section R405A.1 Compliant Software Page 1 of 4 1*, FORM R405-2014 PROJECT Title: BLUE GARAGE Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 468 Lot # Owner. Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County. St. Lucie Jurisdiction: Whole House Fan: No City, State, Zp: Family Type: Single-family FL, New/Existing: -New (From Plans) Comment: CLIMATE J IECC Design Temp Int Design Temp Heating Design Dally Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days. Moisture Range FL, Fort Pierce FL_VERO BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 468 6271.2 SPACES Number Name Area Volume. Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BATHROOM 78 1045.2 No 0 1 Yes Yes Yes 2 OFFICE 2 130 1742 No 0 1 Yes Yes Yes. 3 BREAKROOM 104 1393.6 No 0 1 Yes Yes Yes 4 OFFICE 156 2090 No, 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet I Slab -On -Grade Edge Insulation BATHROOM 19 ft 0 78 ft2 1 0 0 2 Slab -On -Grade Edge Insulation OFFICE 2 loft 0 130 ft? 1 0 0 3 Slab -On -Grade Edge Insulation BREAKROOM 8 ft 0 104 W 1 0 0 4 Slab -On -Grade Edge Insulation OFFICE 25 ft 0 156 W 1 0 0 ROOF .Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 507 ft2 0 ft2 Light 0.6 No 0.9 No 0 22.6 ATTIC y # Type Ventilation Vent Ratio (1 in). Area RBS IRCC 1 Full attic Vented 150 468 ft2 N N 514/2017.3:08 PM. EnergyGaugeO USA- FlaRes2014 Section R405.4.1 Compliant Software. Page 2 of 4 FORM R40.5-2014 CEILING # -Calling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BATHROOM 30 Blown 78ft2 0.1 Wood 2 Under Attic (Vented) OFFICE 2 30 Blown 130 ft2 0.1 Wood 3 Under Attic (Vented) BREAKROOM 30 Blown 104 ft2 0.1 Wood 4 Under Attic (Vented) OFFICE 30 Blown 156ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 N Exterior Concrete Block - Ext Insd3ATHROOM 4.1 13 0 13 4 173.3 ft2 0 0 0.6 0 2 E Exterior Concrete Block - Ext InstBATHROOM 4.1 6 0 13 4 80.0ft2 0 0 0.6 0 3 E Exterior Concrete Block - Ext Insul OFFICE 2 4.1 10 0 13 4 133.3 ft2 0 0 0.6 0 4 E Exterior Concrete Block - Ext'Insd$REAKROO 4.1 8 0 13 4 106.7 ft2 0 0 0.6 0 _ 5 E .Exterior Concrete Block - Ext Insul OFFICE 4.1 12 0 13 4 160.0 ft2 0 0 0.6 0 _ 6 S Exterior Concrete Block - Ext Insul OFFICE 4.1 13 0 13 4 173.3 ft2 0 0 0.6 0 _ 7 W Garage Frame: Wood OFFICE 13 36 13.4 482A ft2 0 0 0.600000 0 DOORS - # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated OFFICE None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth _ Separation Int Shade Screening 1 E 4 Metal Low-E Single Yes 0.65 0.25 9.0 ft2 2 it 0 In 1 ft 4 In. None None 2 S 6 Metal Low-E Single Yes 0.65 0.25 15.0 ft2 2 ft:0 in 1 ft4 in None None GARAGE # Floor Area: Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed (Nall Insulation 1 1044 ft2 384 ft2 36 ft 13.4 ft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgtA ACH ACH 50, 1 Wholehouse Proposed ACH(50) .000596 731.6 40.16 75:53 A351 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:10.7 17 kBtuthr 1 Ductless 514/20173:08 PM EnergyGaugeS USA - FlaRes2014 Section R405.4.1 Compliant Software Page of 4 FORM R405-2014 COOLING SYSTEM # System Type . " Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 18.9 18 kBtuthr 540 cfm 0.8 1 Ductless HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 40 gal 60.9. gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' TEMPERATURES Programable Thermostat: N Ceiling Fans: Jan Feb Veo�nting Jan Feb Mar Apr May Jun Jul Jun Au Oct Nov Nov Dec X Maarr Apr Mng. ay Jul Aug Sep Oct X Dec Thermostat 9che_dule: HERS 2006,Reference Hours Schedule Type 1 2 3 4 6 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80: 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 .65 65 65 65 68 68 68 68. 68 PM 68, 68 68 ._ .68 68 68 68 68 68 68 68 68. 5/4/2017 3:08 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION. INSPECTION COMPONENT CRITERIA Project Name: BLUE GARAGE Builder Name: Street: Permit Office: ST LUCIE COUNTY City, State, Zip: , FL, Permit Number: Owner. Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks .or joints in the air barrier shall be sealed. Air -permeable insulation shall not"be,used as -a sealing material. Ceiling/attic The air barrier.in any dropped ceiling/soffit-shall be aligned with the insulation and any gaps in the air barrier shall be sealed: Access . penings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Comers and headers shall be insulated and the junctiomof the foundation Walls and sill plate•shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation -for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing -and skylights and. Rim 'oists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation, shall be installed to maintain permanent contact with underside. and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached.to the crawlspace walls. Exposed earth in unvented.crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, :utility penetrations, and flue shaft openings to exterior or unconditioned, space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installationreadilyconforms to the available cavity spaces. Garage separation Air sealing,shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be airtight, IC rated, and sealed to the drywall._ Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on -exterior wall Exterior walls adjacent to showers and tubs shall. be insulated and the air :barrier installed'separating there from the showers -and tubs. Electrical/phone box. on The air barrier shall be installed behind electrical or communication boxes or air sealed 'boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-fioor or drywall. Fireplace An air barrier'shall be installed on fireplace walls. Fireplaces shall have gasketed doors 5/4/2017 3:09 PM EnergyGauge® USA-;FlaRes2014 Section,R405.4.1 Compliant Software Page 1 of 1 1. New construction orexisting New (From Plans) 0. Wall Types Insulation Area 2. Single family ormultiple family Single-family a.' Concrete Block -Extlnsul,Exterior R=4.1 826.67ft2 b. Frame - Wood, Adjacent R=13c0 482.40 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms o d. NIA R= ft2 5. Is this a worst case? No 10. Ceiling Types Insulation Area a. Under AttiC (Vented) R=30.0 -468.00 ft2 6. Conditioned floor area (ft2) 468 b. NIA R= ft2 7. Windows" Description Area c. N/A R= ft2 a. U-Factor: Sgl,1J=0.65, 24.00 ft2 11. Ducts R ft2 SHGC: SHGC=0.25 b. 'U-Factor. N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: NIA ft2 a. Central Unit 18.0 SEER:18.90 SHGC: d. U-Factor. N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 17.0 HSPFt10.70 Area Weighted Average Overhang Depth: 2.00Q ft. Area WeightedAverageSHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems Cap;40gallons a. Slab -On -Grade Edge -Insulation R=0.0 468.00 ft2 a. Electric EF: 0.98 b. NIA R= ft2 c. N/A E2= ft2 b. Conservation features None 15. Credits None 1 certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through,.the above: energy saving:featureawhlch will be installed .(or exceeded). in this home before final inspection., Otherwise, a new EPL Display Card will .be completed. based on installed' Code Compliant features. Builder Signature:. Date: Address of New Home: City/FL Zip: "Note: This is not aBuilding Energy Rating. if your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. Contact the EnergyGauge Hotline at (321;) 08-1492 or see the EnergyGauge web site,at energygauge.com for information and a list of certifiedRaters. For information about the. Florida, Building Cade, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 11303.1.3 of. the Florida Building Code, Energy Conservation, if not DEFAULT. 6/4/20113 09 PM EnergyGauge® USA - FlaRes2014 - Section R405A.1• Compliant Software Page 1 of 1