TANK INSTALLATION
SETBACKS
[ ] [01]
TANK SIZE (1,] 1200.00 [2]
[ J
[271
SURFACE WATER
FT
[ ] [02]
TANK MATERIAL Concrete
[ ]
[28.]
DITCHES
FT
[ ] (031
OUTLET DEVICE
[ ]
[291
PRIVATE WELLS
FT
[ ] [04]
MULTI -CHAMBERED [ Y N ]
[ ]
[301
PUBLIC WELLS`
FT
[ ] [05]
OUTLET FILTER Polylok PL-122.
[ ]
[311
IRRIGATION WELLS
FT
[ ] (061
LEGEND 1, 01-011-12DC3 2.
[ ]
[32]
POTABLE WATER 75
FT
[ ] [07]
WATERTIGHT
[ ]
[33]
BUILDING FOUNDATIONS 75
FT
[ ] (08]
LEVEL
[ ]
[34r]
PROPERTY LINES 50
FT
[ ] [09.]
DEPTH TO LID
[ ]
[35]
OTHER
FT
DRAINFIELD INSTALLATION
FILLED / MOUND SYSTEM
[ ] (10]
AREA [1] 768 {2] SQFT
[ ]
[36].
DRAINFIELD COVER
[ ] [11]
DISTRIBUTION BOX HEADER X
[ ]
[37]
SHOULDERS
[ ] [ 12 ]
NUMBER OF DRAINLINES 1. 8.00 2:
C ]
[ 38 ]
SLOPES
[ ] [13]
DRAINLINE SEPARATION
[ ]
[39]
STABILIZATION 10/27/2017
[ ] [14]
DRAINLINE SLOPE
[ ] [15]
DEPTH OF COVER
ADDITIONAL INFORMATION
[ ] [16]
ELEVATION [ ABOVE / BELOW ]BM 16.00
C ]
[40]
UNOBSTRUCTED AREA
[ ] [17]
SYSTEM LOCATION
[ ]
[41]
STORMWATER RUNOFF
[ ] [18]
DOSING PUMPS
[, ]
[421
ALARMS
[ ] (19]
AGGREGATE SIZE
[ ]
[431
MAINTENANCE AGREEMENT
[ ] [20]
AGGREGATE.EXCESSIVE FINES
[ ]
[44]
BUILD.ING AREA
[ ] [21]
AGGREGATE DEPTH
[ ]
[45]
LOCATIONCONFORMS WITH SITE PLAN
( ]
[461
FINAL SITE GRADING
FILL / EXCAVATION MATERIAL
[ ] 2] FILL AMOUNT [ ] [47] CONTRACTOR David Whiteside (Accurate Se
[2
[ ] [221 FILL TEXTURE [ ] Lae] OTHER INFILTRATOR WOW E036 (single c
[ ] (241 EXCAVATION DEPTH ABANDONMENT
[ ] [25] AREA REPLACED [ ] [49] TANK PUMPED
[ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED,
Comments: Comments 'are on page 2.
St. Lucie CHD
CONSTRUCTION C APPROVED / DISAPPROVED ] ° Env ro ental §peclellst II Br " J'In.gram (ENVIRONMENTAL HEALTH)
FINAL SYSTEM C APPROVED / DL.SAPPROVED ]:- St. Lucie CHD
Environmental Specialist II B i n J Ingram"(ENVIRONMENTAL HEALTH)
(Explanation of Violations on following page)
DH 4016, 09/09 (Obsoletes all previous editions. which may not be used)
Incorporated: 64E-6.003, FAC
EH Database v 1.0.1 AP1288778 EID1769940
DATE: 09/26/2017
DATE 10/27/20'17
Page 2 of 3
STATE OF FLORIDA
Al
DEPARTMENT OF HEALTH
c ��* ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
WE
APPLICATION #:AP1'288778
PERMIT .#:56-SF-1759940
DOCUMENT #:F11138975
DATE .PAID:05/02/2017
FEE PAID:515•00
RECEIPT #:5,6-PID-3227031
Violation Number Comment
cents
The. system is sized for 3-:bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 460
gpd. New ST installed. new 8x8 chamber DF installed.
No violations, system ok.to cover. Contractor notified-.onsite. Needs final inspection for mound'system and final site grading.
Final system approved. Contractors and building department emailed final .approval.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Databasa v1.0.1 APi:288778 EID1769840
OF �
STATE OF FLORIDA
DEPARTMENT OF HEALTH
+3 ONSITE SEWAGE TREATMENT.AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
APPLICANT: ;Donald Glancy
AGENT: Atlantic Land. Design
PROPERTY ADDRESS: 104 Spring Hill'Dr Jensen Beach, FL34957
LOT: '5 Part Of 6 BLOCK: 1
APPLICATION #: AP1 275226
PERMIT #:56-SF-1738905
DOCUMENT #:F11137074.
DATE .PAID:,02/00/2017
FEE PAID:515.00
RECEIPT #:56-PID-3182555
SUBDIVI"SIGN:. :Spring. Hill ID#: 4504-604=0012-000-0
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE 'OR RULE AND MUST BE "CORRECTED.
TANK:INSTALLATION
[0l] TANK SIZE [ ] 1.050,00 [2]
[021 TANK MATERIAL Concrete
[031 OUTLET DEVICE
(041 MULTI -CHAMBERED [ Y N' ]
1051 OUTLET FILTER Polylok PL-122
1061 LEGEND 1. 01-01'1=03DC4 2.
1071 'WATERTIGHT
[08] LEVEL
[09] DEPTH TO LID
DRAINFIELD INSTALLATION
[10] AREA [1] 504 121 SQFT
[11] DISTRIBUTION BOX HEADER X
[12] NUMBER OF DRAINLINES 1. 4.00 2.
[13,] DRAINLINE SEPARATION
(14.1 DRAINLINE;'SLOPE
[15] DEPTH OF COVER
SETBACKS
]
127.)
SURFACE WATER
FT
[ ]
[28]
DITCHES
FT
[ ]
[29]
PRIVATE WELLS 75
FT
[ ]
[30]
PUBLIC WELLS
FT
[ ]
[31]
IRRIGATION WELLS
FT
[ ]
[32]
POTABLE. WATER 24
FT
[ ]
[33]
BUILDING FOUNDATIONS' 5
FT
[ ]
[34]
PROPERTY LINES 5
FT
[35]
OTHER
FT
FILLED /MOUND SYSTEM
J
[36]
DRAINFIELD COVER
J
[37]
SHOULDERS
[ ]
[38]
SLOPES
[ ]
[39]
STABILIZATION
[161 ELEVATION [ .ABOVE / BELOW 1BM.:6.00 I_ ]
[17.1 SYSTEM LOCATION L }
[18,] DOSING PUMPS [ ]
[191 AGGREGATE' SIZE [ ].
[201 AGGREGATR EXCESSIVE FINES [` l
[211 AGGREGATE DEPTH [ ]
ADDITIONAL INFORMATION
[40.1 UNOBSTRUCTED -AREA
[41] STORMWATER RUNOFF
[42.1 ALARMS
[43,] MAINTENANCE AGREEMENT-
['44] BUILDING AREA
JA5:1 LOCATION CONFORMS WITH SITE'PLAN
FILL / EXCAVATION MATERIAL [46.J FINAL SITE GRADING
[ ] [221 FILL AMOUNT [ ] [47] CONTRACTOR David Whiteside (Accurate Se
[ ] [23] FILL TEXTURE [ ] (48] OTHER INFILTRATOR Quick4 EQ36 (single c
[ ] [241 EXCAVATION DEPTH ABANDONMENT
[ ] [25] AREA REPLACED [ ] [49] TANK PUMPED
[ ]. [2'6] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED &,FILLED
Comments: Comments are -on page 2,
CONSTRUCTION [ -APPROVED ( St Lucie. 'CHD DATE:: 08/1412017
DISAPPROVED' ]' Environmental Spec allsfll a i J,Ingram (ENVIRONMENTAL HEALTH)
FINAL SYSTEM ( APPROVED /' DLSAPPROVED ]: St. Lucie CHD DATE:: 1.0/17I2017
En ironmentaI.Specialist' 11 Sri J Ingram (ENVIRONMENTAL HEALTH)
(Explanation of Violations on .following page)
DH 4016, OB/09 (Obsoletes all previous editions which may not.be used)
Incorporated: 64E=6.003, FAC Page 2 of 3
EH Database v1,0.1 AP1275226 EID1738905
:-STATE, OF FLORIDA
,DEPARTMENT OF HEALTH
c ONSITE -SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
• ~moo ae
Violation Number Commen
is
APPLICATION #:AP1275226
PERMIT #:'56-SF-1738905
DOCIIMENT '#:F11137074
DATE PAID:'02/09/2017
FEE PAID:515.00
REcEIP.x #:56--PID-3182555
The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400
gpd. New ST and DF. 2x11+2x10=42 chambers.
No violations, system ok to.covet. Contractor notified onsite. Needs final inspection for gutters.
Well checked at construction inspection. No violations, final system approved. Contractor and building department emailed final
approval..
DH 4016, 08109 (Obsoletes.All previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v1.0'A AP1275226 EID1738906