Project Name:
Project Address: Z% 0,3 /�'CA t 2re A/v,C
y Permit #: / 7,06 — OS 91 Occupancy Type: Construction Type: A6c1
INSTRUCTIONS FOR USE:.
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure-
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2014 Building Code Fifth Edition with 20 N/A Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: _I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 160 mph X ASD LRFD End Zone Width: 6 ft
5. Mean Roof Height tq ft Roof Pitch: 6 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly lab I on all plan openin s):
4-w.L TZ,z �-zorZ 3 1 �3�1 *277
Zone 1: -- 31,1 Zone 2: "S5',% Zone 3:� Zone 4: -ffe, Zone 5: Garage: —Nil
7. Design Loads: Floor: ' 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For St(ruu�cturee?/jam Yes Not Applicable Explain Why Not:
6
" v
9. is A Continuous Load Path Provided? X
Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces saecified:.' :. J.
lP0-; j-r'0 T woly— Z,
Print Name
A/ 03-U-C- &_&%6 fAJ
a 63,1 Scv /LJ tv&?
Company Name & Address
74 1
Cert # & Co. Cert Auth.
4-/C